IcntcJ low - pitcbcJ pyromiJol bippcJ roo. Contoins bol - boscmcnt oportmcnts. Built in tbc 197us Proposed Strategy Weather Stripping and Air Sealing the home Replacing wall insulation and reinsulating the attic Replacing the exterior doors to a steel door with a polyurethane core Adding an HRV system Replacing windows with triple glazed, low- argon gas filled units with fiberglass framing Adding a High Efficiency Furnace Replacing the current interior light fixtures to LEDs Adding Light Tubes Using High Efficiency home appliances Ground Source Heat Pump Annual Electric Consumption (kWh) Annual N. Gas Consumption (MJ) Annual GHG Emissions (tons/yr) Estimated Annual Energy Cost ($) Baseline 24,000 548,000 40 5,800 Retrofit 1,200 10,100 11 1,670 Natural Gas Electricity Total Energy Savings/yr 70014 MJ 22042 MJ 92056 MJ Cost Savings/yr $404.26 $928.68 $1,332.94 GHG Reductions/yr 4.13 t CO 2 eq Table 2: Savings from Behavioural Changes Tabl e 1: Energy, Cost and GHG Emi ssi ons bef ore and af t er Ret rof i t -$100.00 -$80.00 -$60.00 -$40.00 -$20.00 $0.00 $20.00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 N P V ,