SDI-12 Output: Output has four parameters: Sensor Temperature (degrees C) Depth (feet) Depth (metres) Depth (fathoms) Example interaction: Blue is SDI-12 poll from logger, red is SDI-12 response from sensor. 0M! 00064 0 0D0! 0+11.0+8.0+2.4+1.3 The above SDI-12 response should be parsed as: Temperature: 11.0 degrees C Depth: 8.0 feet = 2.4 metres = 1.3 fathoms
Specifications: Supply voltage: 7-24 volts DC Supply current: 2 mA idle, 120 mA during measurement Interface: 3-wire, SDI-12 v1.3 Response time: 6 seconds Dimensions (pcb, not including DT800 sensor): 15mm x 65mm Can also be mounted along cable. Inquire for details.
For sales information, contact: ENVCO info@envco.co.nz For technical information, contact: Scienterra Limited RD-6D Whiterocks Road Oamaru, Otago 9492 New Zealand info@scienterra.com