You are on page 1of 18

Installation Guide For VIRDI-3000 V1.

1 VIRDI-3000 Fingerprint Identification System

Version 1.1 Version 1.1 Mar.,20.2007 Mar.,20.2007 Union community Co., Ltd. Union community Co., Ltd.

Installation for V3000 V1.1

1. External Connectors

GND (BK) Door Monitor2 (BL) Door Monitor1 (GR) Door Monitor0 (YE) Inside Open (OR) Lock GND (BK) Lock Out 2 (RE) Lock Out 1 (BR) -

8 7 6 5 4 3 2 1

D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

J203 Door Lock Interface

FGND (GR) - 3 GND (BK) - 2 +12V (RE) - 1

P-3 P-2 P-1

J251 Power Adapter

Voice(-) Voice(+)

D-2 D-1

J301 Interphone Interface

J501 Network Interface (UTP)


Installation for V3000 V1.1

2. Connecting Door phone

Pin8(Black)

Pin4(Orange)

RED
1

Black

(Door Open)

S1 S2

(Door Open)

Installation for V3000 V1.1

3. Connecting Ethernet (LAN) Cable

UTP 10Base-T

Switch Hub or Hub

** UTP Connector

Installation for V3000 V1.1

4. Main Board Feature

J251 DC Power Input

J203 Lock Interface Cable J301 Door Phone Cable

J501 Ethernet Interface J253 DC Power Input Voltage bypass Output

Fuse J252 DC5V Output J105 Wiegand Out Interface J106 Wiegand IN Interface SW102 RS-485 Termination Resistor Select Switch

SW202 SW203 SW201 SW204

RS-232 Serial Port

SW205 Lock Mode Select RV201 Audio Volume Control SW101 RS232 Level Select 232TTL: Inside RF/Smart Card Module RS232 : Using J103 RS232 Serial Port

SW1 Reset Switch J151 Fingerprint Sensor

Installation for V3000 V1.1

5. Schematic for Door Lock Interface

VIN

SW202 DJMM-12V 1

Strike/MT 3 Auto Door 2


5V K

LM_COM1
10 9 8 3 5

LM_NC LM_NO
2 3

NC3
2

SW201 DJMM-12V 1 K

Lock OUT 1
1 PV202 A260LJT2 2

Motor
1 SW203 DJMM-12V

4 DC206 104C2 1 12 Q203 KN2222AS E

LockCon1

1 1

R220 102R R221 473R

PV201 A260LJT2 2

D201 M4 2

NO Motor AutoDoor

2 B 2

K201 G6S-2

Strike AutoDoor

D202 M4

5V

K203 G6S-2 9

10 8 VIN

3 DC216 104C2 4 1 12 Q204 KN2222AS E 5

LM_COM1 2 LM_COM2
3

AutoDoor
1 SW204 DJMM-12V K A

LockCon2

1 1

R237 102R R238 473R

PV209 A260LJT2 2

D207 M4 A 2

Lock OUT 2
1 2

Motor/Strike
LM_COM2 D208 PV210 M4 A260LJT2

2 B 2

1.0mm

Installation for V3000 V1.1

6. Connecting Dead-Bolt Type Door Lock(Fail Safe)


6.1. Connect with one system & one Lock

Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC
- C+
ON WnP

(-)Black (+)Red

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock

12 3 4

SW205 In-Lock N.O Strike

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin8
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin5 Pin4 Pin3 Pin1

Door Monitor

Inside Door Open S/W

Installation for V3000 V1.1

6. Connecting Dead-Bolt Type Door Lock ( Fail Safe )


6.2. Connect with two system & one Lock
System 1 Lock Type Select S/W
SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

System 2 Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC
- C+
ON WnP

(-)Black

(+)Red
12 3 4

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock

SW205 N.O Strike In-Lock In-Lock N.O Strike

SW205

System 1
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin5 Pin3 Pin1

Door Monitor

System 2
GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin8
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin5 Pin2 Pin1

Installation for V3000 V1.1

7. Connecting Strike Type Door Lock ( Fail Safe )


7.1. Connect with one system & one Lock

Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

(-)Black (+)Red

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock SW205 In-Lock N.O Strike

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin8
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin5 Pin4 Pin3 Pin1

Door Monitor

Inside Door Open S/W Installation for V3000 V1.1

7. Connecting Strike Type Door Lock ( Fail Safe )


7.2. Connect with two system & one Lock
System 1 Lock Type Select S/W
SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

System 2 Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

(-)Black
Auto Motor Door NO Strike Strike Motor Motor N.C Ext-Lock Auto Motor Door NO Strike Strike Motor Motor N.C Ext-Lock

(+)Red

SW205 N.O Strike In-Lock In-Lock N.O Strike

SW205

System 1
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin5 Pin3 Pin1

Door Monitor

System 2
GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin8
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin5 Pin2 Pin1

Installation for V3000 V1.1

10

8. Connecting Strike Type Door Lock ( Fail Secure )


8.1. Connect with one system & one Lock

Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

(-)Black (+)Red
Auto Motor Door NO Strike Strike Motor Motor N.C Ext-Lock SW205 In-Lock N.O Strike

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin8
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin5 Pin4 Pin3 Pin1

Door Monitor

Inside Door Open S/W

Installation for V3000 V1.1

11

8. Connecting Strike Type Door Lock ( Fail Secure )


8.2. Connect with two system & one Lock
System 1 Lock Type Select S/W
SW204 SW201 SW203 SW202 Auto Strike Motor Door Motor NC

System 2 Lock Type Select S/W


SW204 SW201 SW203 SW202 Auto Strike Motor Door Motor NC

(-)Black (+)Red
Auto Motor Door NO Strike Strike Motor Motor N.C Ext-Lock Auto Motor Door NO Strike Strike Motor Motor N.C Ext-Lock SW205 In-Lock N.O Strike In-Lock N.O Strike SW205

System 1
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin5 Pin3 Pin1

Door Monitor

System 2
GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1 D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin5 Pin3 Pin1

Installation for V3000 V1.1

12

9. Connecting EM Type Door Lock ( Fail Safe )


9.1. Connect with one system & one Lock

Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock

(+)Red

(-)Black

SW205 In-Lock N.O Strike

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin8
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin5 Pin4 Pin3 Pin1

Door Monitor

Inside Door Open S/W

Installation for V3000 V1.1

13

9. Connecting EM Type Door Lock ( Fail Safe )


9.2. Connect with one system & two Lock ** Use external DC Power Adapter
Lock Type Select S/W
SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

Lock 1

Auto Motor Door NO

Strike Strike Motor

Motor N.C Ext-Lock SW205 In-Lock N.O Strike

- (Black) + (Red) Lock(-) Lock(+)

12V 3A Adapter

(-) (+)

Door Monitor

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

Pin8
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin5 Pin4 Pin2 Pin1 Inside Door Open S/W

Lock 2

Installation for V3000 V1.1

14

10. Connecting Auto Door ( Contact Control )


10.1. Connect with one system & one Lock

Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC Auto Door Operating Part Auto Door Motor

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock

Auto-Door Sensor

Auto-Door Monitor
Sensor Input Line

9P CONN
SW205 In-Lock N.O Strike

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin2 Pin1

Inside Door Open S/W Installation for V3000 V1.1

15

10. Connecting Auto Door ( Contact Control )


10.2. Connect with two system & one Lock
Auto Door Operating Part Auto Door Motor

System 1 Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

System 2 Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

Auto-Door Sensor

Auto-Door Monitor
Sensor Input Line

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock

9P CONN

SW205 In-Lock N.O Strike N.O Strike GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1 GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1 In-Lock

SW205

System 1
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin2 Pin1

System 2
D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin2 Pin1 Installation for V3000 V1.1

16

11. Connecting Motor Lock

Lock Type Select S/W


SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock

Blue Brown White Orange Yellow Black RED

SW205 In-Lock N.O Strike

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin8 Pin7 Pin6 Pin5 Pin4 Pin3 Pin2 Pin1

Ground Unlock Signal Locking Signal Door Monitor Ground Motor 2 Motor 1

Inside Door Open S/W Installation for V3000 V1.1

17

12. Connecting 2 Emergency Lamps


Lock Type Select S/W
SW204 SW201 SW203 SW202 Strike Auto Motor Door Motor NC

Emergency Lamp 1

Emergency Lamp 2

Auto Motor Door NO

Strike Strike Motor Motor N.C Ext-Lock SW205 In-Lock N.O Strike

12 V (+)

Ground (-)

12 V (+)

Ground (-)

GND(BK)-8 DOOR MONITOR2(BL)-7 DOOR MONITOR1(GR)-6 DOOR MONITOR0(YE)-5 INSIDE OPEN(OR)-4 LOCK GND(BK)-3 LOCK OUT 2(RE)-2 LOCK OUT 1(BR)-1

D-8 D-7 D-6 D-5 D-4 D-3 D-2 D-1

Pin3 Pin2 Pin1

Installation for V3000 V1.1

18

You might also like