You are on page 1of 1

Fresh Water Generator Dosing

Chemical Used: Unitor Vaptreat a concentrated liquid blend of polymer and antifoam agents for scale and foam controlling in the evaporator. Dosage Calculation: Standard dosage rate = 15 30 ml of chemical per ton of distilled water produced. Production capacity of FWG = 25 ton/day Hence, Treatment used = 30ml/ton x 25ton/day = 750 ml per day. Flow rate setting Chemical tank capacity = 50 liters. Standard flow meter is adjustable between 0 100ml / minute Flow rate = 50 liters/24 x 60 = 35ml/min setting. This lasts for 24 hrs. A metering pump is used for this purpose. Benefits of chemical dosing Evaporator works at maximum efficiency by keeping heat transfer surfaces free of scale. The antifoaming properties of chemical ensure that the distillate quality is high as carryover is eliminated. Reduced downtime and maintenance.

You might also like