You are on page 1of 4

32'-8"

BUILD UP RAMP 6"

4'-0"

10'-0"
EXISTING HOUSE SIDE VIEW WITH PORCH

PORCH AREA

22'-8"
BUILD UP RAMP 1:10

4'-0"

PLAN VIEW OF EXISTING HOUSE

30'-0"

48'-0"

EXISTING BLDG

PARKING SIGN SEE DETAIL 1


4" 1'-0" 1'-6"

6'-0"

10'-0"
4'-0" ELEV. 2.0
1 10

5'-0"

6'-0"

6'-0"

22'-0"

ELEV. 0.0
1'-6"

PARKING BLOCK

RCC, INC 1365 BROAD ST JOHNSTOWN, PA 15906

6"

CONCRETE BUILD UP RAMP TO DOOR

ELEVATION OF PARKING LOCATION TO BUILD UP RAMP

0126 01-26-2011 N.T.S.

ADA PARKING SPACE MENOHER BLVD JOHNSTOWN, PA


DET2

16'-3"

7'-0"

22'-0"

1
7,8 DET-13 2,4,5 DET-13

2
7,8 DET-13 2,4,5 DET-13

4
2,3,4,5 DET-13 7,8 DET-13 1 DET-14

4'-0"

14'-0"

TOP OF MASONRY

DFL
3'-9"

DS

12'-9"

12'-0"

DS

SOUTH ELEVATION WEST END DPS-6


1 2 7 3 4 7
EXTERIOR DOOR SCHEDULE
DOOR NO. DOOR TYPE MASONRY OPENING WIDTH SIZE HEIGHT THK FRAME MATERIAL DOOR FRAME FINISH DOOR HEAD DETAILS JAMB SILL HDWRE SET NO. WIDTH FLOOD BARRIER HEIGHT TYPE REMARKS

12'-0"

12'-0"

4'-0"

1 2 3

E E B J D A A A C G F H F H F K C I A

12'-0" x 12'-0" 12'-0" x 12'-0" 12'-0" x 14'-0" 4'-0" x 12'-2" 14'-0" x 14'-0" 4'-0" x 12'-10" 4'-0" x 12'-10" 4'-0" x 12'-10" 14'-0" x 12'-0" 4'-0" x 7'-10" 13'-6" x 8'-5" 4'-0" x 8'-6 3 4" 13'-6" x 8'-5" 4'-0" x 8'-6 3 4" 13'-6" x 8'-5" 4'-0" x 11'-0" 14'-0" x 12'-0" 4'-0" x 8'-9 12" 4'-0" x 12'-10"

12'-0" 12'-0" 12'-0" 3'-6" 14'-0" 3'-6" 3'-6" 3'-6" 14'-0" 3'-6" 13'-6" 3'-6" 13'-6" 3'-6" 13'-6" 3'-6" 14'-0" 3'-6" 3'-6"

12'-0" 12'-0" 14'-0" 8'-0" 14'-0" 8'-0" 8'-0" 8'-0" 12'-0" 7'-8" 8'-5" 8'-4" 8'-5" 8'-4" 8'-5" 6'-8" 12'-0" 8'-7" 8'-0"

1 3" 4

STEEL STEEL STEEL ALUM STEEL

STEEL STEEL STEEL

GALV & PNT. GALV & PNT. GALV & PNT.

GALV & PNT. GALV & PNT. GALV & PNT.

1/A644 1/A644 1/A644 6/A643 1/A644 6/A643 1/A643 1/A643 4/A644 11/A643 1/A644 11/A643 1/A644 11/A643 1/A644 7/A647 4/A644 11/A643 1/A643

2/A644 2/A644 2/A644 9/A643 2/A644 9/A643 4/A643 4/A643 2/A644 12/A643 2/A644 12/A643 2/A644 12/A643 2/A644 10/A647 2/A644 12/A643 4/A643

3/A644 3/A644 8/A644 10/A643 7/A644 10/A643 5/A643 5/A643 7/A644 13/A643 5/A644 13/A643 5/A644 13/A643 5/A644 11/A647 8/A644 13/A643 5/A643

1 1 1 2 1 2 2 2 1 3 1 3 1 3 1 3 1 3 2

NA NA 12'-0" 4'-0" 14'-0" 4'-0" 4'-0" 4'-0" 14'-0" NA NA NA NA NA NA NA 12'-0" NA 4'-0"

NA NA 3'-9" 3'-1" * 4'-0" 3'-9" 3'-9" 3'-9" 4'-0" NA NA NA NA NA NA NA 4'-0" NA 3'-9"

NA NA NOTE 3 NOTE 4 NOTE 3 NOTE 4 NOTE 4 NOTE 4 NOTE 3 NA NA NA NA NA NA NA NOTE 3 NA NOTE 4 ALUM/GLASS TRANSOM GASKETED PIPE GASKETED PIPE GASKETED PIPE ALUM/GLASS TRANSOM ALUM/GLASS TRANSOM ALUM/GLASS TRANSOM * MIN. HEIGHT OF BARRIER, STD. LARGER SIZE ACCEPTABLE ALUM/GLASS TRANSOM

12'-0"

12'-0"

4 5 6 7 8 9

ALUM/GLASS BAKED ENAM. BAKED ENAM. STEEL GALV & PNT. GALV & PNT.

1 3" 4 1 3" 4 1 3" 4

ALUM ALUM ALUM STEEL

ALUM/GLASS BAKED ENAM. BAKED ENAM. ALUM/GLASS BAKED ENAM. BAKED ENAM. ALUM/GLASS BAKED ENAM. BAKED ENAM. STEEL GALV & PNT. PAINTED GALV & PNT. PAINTED GALV & PNT. PAINTED GALV & PNT. PAINTED GALV & PNT. PAINTED GALV & PNT. PAINTED GALV & PNT. PAINTED GALV & PNT. PAINTED GALV & PNT. PAINTED GALV & PNT. PAINTED

14'-0"

10

1 3" 4

HOLLOW MTL HOLLOW MTL STEEL STEEL

12'-9"

11 12 13 14 15 16 17 18 19

1 3" 4

HOLLOW MTL HOLLOW MTL STEEL STEEL

1 3" 4

HOLLOW MTL HOLLOW MTL STEEL STEEL

1 3" 4

HOLLOW MTL HOLLOW MTL STEEL STEEL

1 3" 4 1 3" 4

HOLLOW MTL HOLLOW MTL ALUM

ALUM/GLASS BAKED ENAM. BAKED ENAM.

3'-9"

DFL TBM

GENERAL NOTES: 1. ALL GLASS SHALL BE RATED FOR LARGE MISSILE IMPACT (LMI) 2. ALL DOORS TO BE HURRICANE RESISTANT (156 MPH GUST SUSTAINED FOR 3 SECONDS). 3. REMOVABLE ALUMINUM GASKETED STOP-LOG SYSTEM. SEE DETAILS: 6/A644 & 7/A644

12'-0"

4. ADJUSTABLE ALUMINUM LIFT-OUT FLOOD BARRIER. SEE DETAILS: 14/A643 & 15/A643 5. SEAL OPENINGS TO DFL 6. REINFORCING NOT SHOWN IN ALUMINUM FRAMES FOR CLARITY

DS

DS

DS

DS
LEFT SIDE

DS
RIGHT SIDE

SOUTH ELEVATION WEST END DPS-6 SECTION 1


NEW C10X30 SEE STRUCTURAL JEMS B16 EXIST. BRICK MASONRY
1A E8A

TYP.
16

DOOR SCHEDULE FOR JEMS


1 2 3

EXISTING GLAZED BRICK

CONNECTIONS PER DOOR MFR'S DETAILS BRACING BEAM

EXISTING GLAZED BRICK

NEW C10X30 CHANNEL NOTCHED TO ALLOW MET FLUSH WITH EXISTING STL PLATE. JEMS B16 NEW C10X30 CHANNEL JEMS B16 EXISTING GLAZED BRICK

(GRUENSTARK TL10) SET IN EXIST. MASONRY W/ SOCKED TAPER-LOK ANCHOR INJECTED W/ C.I.F. (4" EMBED.)

C8x11.5 JEMS B18 OPEN

1"

PROVIDE REMOVABLE FLOOD BARRIER FOR OPENING. SEE DOOR SCHED, SHEET A-611 FOR SIZES

EXISTING CEMENT FACE

SILL BELOW
1 3/8"

4 1/2"

TYP.

1
4
C10x30 JEMS B16

12'-0" 12'-0"
L4x4x5 16x0'-10" CLIP ANGLE W/2- 3 4 BOLTS INTO EXIST. CONC. FLOOR (4 3 4" MIN. EMBED.) TYP. JEMS A7

12'-0" 12'-0"
DS

BENT PLATE GALV. STEEL (EXIST.)


3 8"

1 2"

NEW CONCRETE TO FILL POCKET VOID TO SET NEW C10X30 WITH 3 8" ROD ANCHORS JEMS B16

M.O.

EXIST. 12" CONC. FLOOR SYSTEM.

VARIES FIELD VERIFY

DIA ROD ANCHOR

INSIDE VIEW

DOOR STRUCTURAL FRAMING


Scale: N.T.S.
VARIES PER DOOR

DFL TBM

3'-9"
DS

OVERHEAD ROLL-UP

DS

EXISTING STL HEAD PLATE

SOUTH ELEVATION WEST END DPS-6

Scale: N.T.S.

VARIES PER DOOR

DETAIL FOR NEW BEAM C10X30 (JEMS B16)


Scale: N.T.S.
METAL HOOD. ANCHOR TO WALL PER OVERHEAD DOOR MFR'S DETAILS NEW C8X11.5 SEE STRUCTURAL. JEMS B18

1A

DETAIL FOR NEW C10X30 CHANNEL JEMS B16

NEW C8 X 11.5 NOTCHED TO ALL DOOR HARDWARE AND FRAMING NEW C8 X 11.5 JEMS B18
3 8"

DIA ROD ANCHORS

EXISTING LINTEL ANGLES 1 EXISTING 2" STL PLATE. EXIST. STEEL PLATE BEYOND TRACK BEYOND PER DOOR MFR

NOTES 1. NEW C10X30 CHANNEL PER DETAIL PROVIDED TO JEMS SHOWN TO BE SET FLUSH WITH EXISTING INTERIOR AND TO BE SET BEHIND EXISTING WING FLANGE OF 1/2" BENT PLATE PER DETAIL 2/A644. 3. PER DETAIL NEW C10X30 CHANNEL TO BE ANCHORED USING 3/8" DIA. RODS WITH TAPER-LOC EMBED 4". 4. ANCHORS NOT TO EXCEED 1'-4" SPACING LENGTH OF NEW C10X30 CHANNEL.

SEE DRAWING DET-13 SECTION DETAILS

NEW C10X30 JEMS B16

C10X30 JEMS B16 & C8X11.5 JEMS B18


Scale: N.T.S.

SECTION 1

SECTION 2

SECTION 3

SECTION 4

NEW C8X11.5 JEMS B18


Scale: N.T.S.

Seq Shipping No. Mark JEMSL5 JEMSL5 JEMSL6

No.

Assem. Mark L5 L5 1R&1L 2R&2L 3R&3L CL1 CL2 PL3 DPS6 DPS6 DPS6 70 105 100 100 100 290 290 150 600 1200 600

SHOP BILL
Description L4"X4"X1/4" ANGLE L4"X4"X1/4" ANGLE L3"X3"1/4" ANGLE L3"X3"1/4" ANGLE L3"X3"1/4" ANGLE 3"X3"3/16"X9" ANGLE 3"X3"X3/16"X4" 3/8"X4"X9" 3/4"X2" GRADE 8 3/4" FLAT 3/4" 11 11 11 12 14

Length Ft. Inches 6 6 6 6 6 9 4

Remarks DRAWING E-2 DRAWING E-3 DRAWING DET-11 DRAWING DET-11 DRAWING DET-11 DRAWING DET-8 DRAWING DET-8 DRAWING DET-10 DRAWING DET-8 DRAWING DET-8 DRAWING DET-8

JEMSL6 JEMSL6 JEMS CL1 JEMS CL2 JEMS PL3

A
EXIST. 2-L212"x2"x5 16 " EXIST. 2-L212"x2"x5 16 "

BOLT
EXIST. 2-L21 2"x2"x5 16"

WASHER
EXIST. 2-L21 2"x2"x5 16 "
A

SIM. @ NEW ANGLE TO BOT. CHORD CONN.

EXIST. 2-L212"x2"x5 16"


A
SIM. SIM.

SIM. @ NEW ANGLE TO BOT. CHORD CONN.

NUT

EXIST. MASONRY WALL

EXIST. MASONRY WALL

3"

6'-3"

6'-6"

6'-6"

12'-0 3/16"

6'-6"

6'-6"

6'-3"

3"

47'-11 1/2"

21

11

2'+

OR B

50'-5 7/8"

1
11
NEW L4"x4"x14" CONT. BOT. BRIDGING. SEE DET. A TYP. JEMSL5

EXISTING ROOF FRAME SECTION S-145


Scale: N.T.S.

EXISTING ROOF FRAMING PLAN SHOWN WITH NEW ANGLE


SCALE: N.T.S.

NEW L4"x4"x14" CONT. BOT. BRIDGING. SEE DET. A TYP. JEMSL5

EXIST. L212"x2"x5 16"


EXIST. L2"x2"x1 4"

EXIST. L

9"

EXIST. L212"x2"x5 16"

NEW L3"x"3x3 16" JEMS CL1 W/2-3 4"OD X 2" BOLTS


2-3/4"

NEW L3"x3"x3 16"x0'-4" JEMS CL2

EXIST. 2-C5x6.5 EXIST. 2-L212"x2"x5 16"

EXIST. 2-L212"x2"x5 16"

NEW L4'x4"x1 4" (CONT.) JMESL5

DETAIL FOR NEW L4"X4"X1/4" JEMSL5


Scale: N.T.S.

NEW L4"x4"x14" (CONT.) JEMSL5

NEW L4"X4"X1/4" JEMS L5


Scale: N.T.S.

1-1/2"

3"

3"

NEW L4"x4"x14" JEMS L5

SINGLE ANGLE

NOTES 1. SEE DETAILS"C" & "D" FOR NEW ANGLE TO EXIST. SINGLE OR DOUBLE ANGLE CONNECTION.

NEW L1"X1"X1/8"
Scale: N.T.S.

4"

9"
NEW L3"x3"x3 16"x9"
(JEMS CL-1) W/2-3 4"OD

2"

GRADE 8 BOLTS

GRADE 8 BOLTS

WASHER

3"

X2"

(JEMS CL-1) W/2-3 4"OD

X2"

3"
3"
2-

EXIST. 2-L

NEW L3"x3"x3 16"x9"

5-13/16"

1-1/2"

3"

13

/1

6"

1-1/2"

3" 1-1/2"

3"
DOUBLE ANGLE

3"

3"

NEW L4"x4"x1 4" JEMS L5

1/4"

Scale: N.T.S.

3/4"
GRADE 8 BOLT

NEW 3"X3"X3/16" CLIP JEMS CL1


Scale: N.T.S.

1-1/2"

NEW L1"X1"X1/8"
Scale: N.T.S.

NOTES 1. SEE DETAILS"C" & "D" FOR NEW ANGLE TO EXIST. SINGLE OR DOUBLE ANGLE CONNECTION. 2. DRILL (2) TWO 7 8" HOLE IN CLIP TO ATTACH TO NEW 4"X4"X1 4" ANGLE (JEMS L5) 3. USE (2) 3 4" X 2" GRADE 8 BOLTS 4. 1 4" CREASE BEND TO OVERLAP EXISTING 2-1/2"X2" L

NOTES 1. 7 CONTINIOUS NEW ROWS OF L 4"X4"X1/4" ANGLE IDENTIFIED AS JEMSL5 ON DRAWINGS 2. NEW JEMSL5 TO CONNECT AT BOTTOM OF EXISTING FRAMES NUMBERS 11 THRU 21 PER DRAWING S-145 3. SPACING BETWEEN FRAMES PER DRAWING S-145 11'-3". 4. SEE DETAIL ON POINT OF CONNECTION FROM EXISITNG FRAME TO NEW L4"X4"X1/4" JEMSL5

SHEET S-144

SHEET S-145

SHEET S-146

3/16"

NEW 3"X3"X3/16" X4" JEMS CL2

ADA BATHROOM MEN

ADA BATHROOM WOMEN

You might also like