You are on page 1of 1

Data LOA B D Longest Compartement Number compartement

= = = = =

42 15.6 1.4 9.6 12

m m m m , 6 for each hull

Where a bilge main is fitted, it's internal diameter dm is to be not less than that required by the following formula dm = 69.95 mm The diameter db of branch bilge suction pipes is to be not less than that required by the following formula: db = = 39.97 mm

Capacity Q of each bilge pumping unit or bilge pump is to be not less than that required by the following formula: = Q = 28.13 m /hr
3

Where fixed submersible bilge pumps are fitted, the total capacity Qt of the pumps is to be not less than that required by the following formula: Qt = = 67.52 m3/hr

The capacity Qn of each submersible bilge pump is to be not less than that required by the following formula: Qn = Each compartement will be suited with one pump, at engine room will have 2 pump, total bilge pump (N) is 3 Qn = 5.19 m /hr Design specification Bilge pipe Pump Capacity 14

= DN 50 (ID 53.3 mm) and DN 40 (ID 41.3) = Rule 3700 submersible bilge pump 11.4 m3/hr