Codes Displayed by the MicroBasic Controller REASON FOR LIFT NOT STARTING (A) COMPONENT Safety circuit fuse

(FM) blown Safety circuit open Motor therms or machine room temperature device tripped 110% load Attendant control active Door contact open - manual doors Door open push (PAP) or door sensitivity (SEN) or photocell (CEL) open Car door contact and landing lock circuit open Car or hall call for floor where car is positioned (keeping doors open) LIST OF CONDITIONS (E)
CONDITION - (DIGIT NOT FLASHING) CONDITION - (DIGIT NOT FLASHING)

A01 A02 A03 A04 A05 A06 A07 A08 A09

E01 E02 E03 E04 E05 E06 E07 E08 E09 E10 E11 E12 E13 E14

100% overload (active) Attendant control (active) car door & landing locks (closed) Safety zone, levelling (active) Safety cct prior to locks (active) Not in use Level circuit (closed) Not in use Lower prelimit [slow limit] (closed) Upper prelimit [slow limit](closed) Inspection control (active) Manual Doors - series cct (closed) Door open cct PAP SEL SEN (closed) STOP cct [sill switch] (open)

E15 E16 E17 E18 E19 E20 E21 E22 E23 E24 E25 E26 E27

Firemans switch [car] (active) Levelling down direction Firemans switch [landing] (active) High speed relay (active) Relay (CB) or (CL) (active) Safety circuit fuse [FM] (closed) Pin f-P2 active, arrival gong trig Lift resetting Temporarily out of service Permanently out of service Lift in travel Lift in slow speed End of service

ERRORS (F) F01 F02 F03 F04 F05 F06 F07 F08 F09 F10 F11 REASON Running timer tripped Safety circuit open Final limit opened and re-closed Stuck contactor circuit tripped Repeat fault - door interlock circuit Series of open doors in operation Series of open interlocks during service Misregulation of pulses Control fuse (FM) or supply open MicroBasic PCB fault Door circuit open too long REASON F12 F13 F14 F15 F16 F17 F18 F19 F26 F27 circuit open too long Car between floors prelimits open Both prelimits open Up prelimit opens in down travel Down prelimit opens in up travel Parameters incorrect (new input) Inverter drive fault (traction lifts)
PAP SEL SEN

Button of operating panel stuck Lift level CPS circuit open CPS not changing going into floor

3VFMAC-DSP Frequency Converter

PROVISIONAL AND PARTIAL


Technical Dossier
V0.2, MAR.04 English / 3VFMAC-DSP_UK

Installation Assembly Star-Up Use Maintenance Repair

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
VERY IMPORTANT: This document is provisional and includes partial information only, which is complemented by the 3VFMAC1 v3.00 frequency changer manual. For any doubts that may arise during the operating of the frequency changer, please consult MP Lifts.
CONTENTS

1. COMPATIBILITY BETWEEN F SERIES AND DSP VERSIONS ........................................................................... 2 2. GENERAL FEATURES................................................................................................................................ 3 2.1. New features ............................................................................................................................... 3 2.2. Technological improvements ......................................................................................................... 3 2.3. Improvements in comfort.............................................................................................................. 3 3. UNIVERSAL CONNECTION ........................................................................................................................ 4 4. GENERAL DIAGRAMS............................................................................................................................... 6 4.1. MicroBASIC controller ................................................................................................................... 6 4.2. SERIE controller........................................................................................................................... 7 5. INFORMATION SUPPLIED BY THE BOARD................................................................................................... 8 5.1. Led indicator lights....................................................................................................................... 9 5.2. Five-digit display (console)............................................................................................................ 9 6. USER INTERFACE...................................................................................................................................11 6.1. Parameterisation.........................................................................................................................12 6.2. Visualising the information through display (monitoring)..................................................................13 6.3. PALM control ..............................................................................................................................14 7. LIST OF PARAMETERS ............................................................................................................................14 8. DESCRIPTION OF ERRORS ......................................................................................................................20 9. ADJUSTMENT AND FINE-TUNING OF THE INSTALLATION ............................................................................22 9.1. Preliminary aspects .....................................................................................................................22 9.2. General adjustments ...................................................................................................................23 9.3. Levelling adjustment ...................................................................................................................24 9.4. Vibrations ..................................................................................................................................25

V0.2 MAR.04

Page 1

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
1. COMPATIBILITY BETWEEN F SERIES AND DSP VERSIONS The new DSP frequency changer is fully compatible with the old F series version, to such an extent that if it is necessary to replace the latter with the new DSP version, neither the wiring nor the original fastenings of the controller need be changed. It is only necessary to reduce the number of poles of the plug-in terminal that is connected in the bottom-left corner of the frequency changer (XC4), which should be reduced from 8 to 6 poles, eliminating the two upper end terminals which are never wired (in F series controllers). The instructions to make this change are described in detail below. INSTRUCTIONS TO CONNECT THE XC4 PACKAGE: 1. 2. 3. 4. Photo 1 shows the connector with terminals 30 and 31 which overhang from the XC4 package of the frequency changer. Photo 2 shows where this connector must be separated (terminals 30 and 31 which are never wired) and the removal of its end cover. Photo 3 shows the new connector with two poles less, with the end cover positioned on the side of terminal 32 which was uncovered. Photo 4 shows the final connection in the PCB of the 3VF-DSP.

End cover

Uncovered side
Photo 1 Photo 2

Photo 3

Photo 4

V0.2 MAR.04

Page 2

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
2. GENERAL FEATURES IMPORTANT: On the date that this document was published, part of the features described below were not yet operational. These are marked with the symbol (). 2.1. New features

Control of the asynchronous and synchronous motor. () Elimination of roll-back effect in start-up, by means of a weight reading by using MPs VK2P weighing system. Modelling of the machine by the direct parameterisation of the motor electrical constants (vector control). () High connectivity of encoders with a high number of pulses. Communication interfaces available: RS-485, ENDAT, SSI, Irda and CAN-BUS, which make it possible to monitor and control the system remotely. ()

2.2. Technological improvements Latest generation DSP technology (Texas Instruments) with 32-bit Flash technology and instruction times of up to 6 nanoseconds.

User-friendly scheduling interface, by using a market PDA terminal (PALM O.S.) without cables (infrared, Irda) or by using an on-board keyboard. Application to gearless motor by operation at very low electrical frequencies (precision: frequencies. 0.0078Hz). High precision vector control with Space-Vector modulation which makes it possible to reduce the heat of the power transistors, allowing higher switching

2.3. Improvements in comfort Direct access due to exact positioning, which makes it possible to remove the landing approach span, eliminating unnecessary waiting times for users. ()

Direct access to landing due to indirect calculation of car weight, eliminating the need for load-weighing switches. Complete lack of electrical noise of the motor due to its switching frequency of up to 20 Khz, enabling its installation in machine room less lifts.

Quality of ride, thanks to self-adjustment of jerk, which eliminates the unpleasant sensation caused by acceleration during starting and stopping. Precision on stopping, without position encoder. Levelling by time or by position (). Standard performance, independent of the supply voltage, thanks to its system which adapts to the network voltage.

V0.2 MAR.04

Page 3

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
3. UNIVERSAL CONNECTION Voltage-free contact control

Machine

M ~3

V K1 U K2

Output filter

Contactors

Input filter
R

General power supply Contactor reading filter

S -CE T C1 +CE C2

CAPACITORS (Only in 10HP, 15HP and 20HP. Supplied with capacitor)

+ -

FLC
*RUN *Nominal speed 2 speeds *Inspection speed 2 Accel. / Decel. *Up / down Reset Error * Necessary connections

Control signals
11 12 13 14 15 16 17 18 19 XC2 XC2 11 12 13 14 15 16 17 18 19 50 49 48 XC9 1 2 3 4 5 XC6 XC6 20 21 22 23 XC3 XC3

+ -

Communication
XC10 VS: control B2 R B1

Communication CAN control

Ground network
C1+ C1C2+ C2-

XC11

Communication VS: encoder

1 2 3 4 5

Brake resistance:
5HP 400V: 60hms, 520W 230V: 20hms, 600W 10HP 400V: 40hms, 1040W 230V: 14hms, 1040W 15HP 400V: 30hms, 1400W

Multipole encoder 5Vdc

0Vac

Low cost encoder Pulse reading

(+) 10V 20 (-) 0V 21 22 23

A1 K1 A2 110Vac

A1 K2 A2

Contactor control

32 33 XC4 34 35 36 37 XC4 XC5

32 33 34 35 36 37

RL1

PCB 3VF DSP

20HP 400V: 30hms, 400W

TRIAC

RL3

Safety series Brake control


24Vdc KRFR

T2 T1

0Vdc

Ventilation fan

V0.2 MAR.04

Page 4

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
It is important to pay special attention to the power cables so that all of these cables (U, V, W, C1, C2, CE+, CE-, B1, B2) remain above the strip of pins in the way the installation is wired in the following photo.

Strip of pins

V0.2 MAR.04

Page 5

3VFMAC-DSP_UK

Provisional

R S T FE 380 Vp 5 COND B + CE - CE 3VF-DSP 14 RMT2 27


A1

SIR TRM 15 110 Vs 20 Vs 60 Vs 48 Vs 80 Vs 0 Vs 106 SCC FM RMT 1 6 12 8 102 SAC SAF

STOP

SLVH

SCTH

SPRS

220

SPRB

220 Vp R S T B1 B2 L1 L2 L3 0 Vp

105

SCE

104 17 RZS RMP

SP

103

STOPF

STLH

SFI

SFS

U V W C1 C2
L1 L2 L3

00

PIN 103 A KRNS RMT1


A2 G2R - 2 110 Vac A1

19 ( MB )

3VFMAC-DSP FREQUENCY CONVERTER

RZS

K1
T1 T2 T3

BYT11 - 1000

0 Vdc

A1

PRODUCT TECHNICAL MANUAL

11
L1 L2 2 T1 1 T2 T3 L3

A1

A 5 RMR T T T RZS RVR 13

K1
A2

K2
A2

A
MY 4 A1 110 Vac

KRREV RPA FLC


34

G2R2 24 Vdc

A2

K2 QIM

3VF-DSP

KRSE
A2 35

A 9 KRL 2
5

208

FS B2 U V W B1

7 RM RF KRSE
9

25 RB 23 24

26

KRFR

GRF

Low cost Encoder connection


M 3~

KRFR

~1

(+)

K1

13

14

206 ( SM )

~2

(-)

K2

13

14

204 ( SM )

220 Vp 0 Vp 48 Vs 60 Vp 0 Vs 110 Vs XC3 20 21 22 3VF-DSP 23 22 ( MB ) SM


(+)
61

K1
62 61

K2
62

KRLE 3 ( MB )
( IN1 )

KRLE 22 KRNS
11 12

11

14

~2 4 ( MB )

(-)

LE ( + )

20

(-)

21

21

24

4.1. MicroBASIC controller

Industrial encoder connection


11 1 3VF-DSP 2 C1 + 3 C1 4 C2 + XC6 5 C2 C2C2+ C1C1+ + + 24 Vdc + 5 Vdc SM FLC a MicroBASIC 24 21 KRNS RET 12 13 14 15

3VF-DSP
16

LE + LE -

~1

GRL (+)

LE ( - )

KRL3

4. GENERAL DIAGRAMS

17

18

19

36

37

KRFR
12 11

MK2P 24 Vdc

12

KRSE

3VF-DSP

KRREV c

11

+ 24 Vdc

0 Vdc

Contactor reading filter

V0.2 MAR.04

Page 6

RS

220 Vp 0 Vp 48 Vs 60 Vp 0 Vs 110 Vs

3VFMAC-DSP_UK

BYT11 - 1000

R S T QIM

SIR 380 Vp 220 Vp 20 Vs 0 Vs 0 Vs SCE 8H 8C KP1 (XSM1) SPC 7C 7H 6H TRM 1H 110 Vs STLH SFI SFS SLVH 2H

Provisional

FE
1 2

SAC

STOPC

2C

3C

3C

SIB

4C

SIS

COND + CE - CE 3VF-DSP B2 B1 U V W C1 C2
L1 L2 L3

R S T

L1 L2 L3

0 Vp

STOPF

6S

5S

5H

5H

3VFMAC-DSP FREQUENCY CONVERTER

K1
T1 T2 T3

B2 K2
A1 62 61 A1

B1 FLC K1
A2

L1

L2

L3

K2
A2

PRODUCT TECHNICAL MANUAL

K2
T1 61 T2 T3

RF K1
62

3VF-DSP

34

FS U V W

24G (XSM1)

Contactor control
KRL 2
35 B S

220 Vp 0 Vp 48 Vs 60 Vp 0 Vs 110 Vs

KRFR KRFR
8 6 1 3

GRF ~1 ~2 (+) (-)

K1

13

14

F2 ( SM )

M 3~

XC3 20

3VF-DSP 21 22 23 3VF-DSP

KRL3 SM
(+)

20

(-)

21

( IN1 )

22

XC10

XC11 11 12

Industrial encoder connection

36

37

C23VF-DSP 2 C1 + 3 C1 4 C2 + XC6 5 C2 C2+ C1C1+ + + 24 Vdc + 5 Vdc SM FLC

KRFR

MK2P 24 Vdc

4.2. SERIE controller

+ 24 Vdc

0 Vdc

X3VF

PCB-SM

XENC

Contactor reading filter

In case of exact positioning

V0.2 MAR.04

Page 7

Low cost encoder connection

13

14

F1 ( SM )

K2

3VFMAC-DSP_UK

BYT11 - 1000

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
5. INFORMATION SUPPLIED BY THE BOARD Below we have included a diagram of the PCB which shows the elements that supply visual information. All of this information is included in the following points.

CONSOLE
V0.2 MAR.04 Page 8 3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
5.1. LED indicator lights
BLOCK A B B B B B B B B C D D D D E E F GENERAL DESCRIPTION High voltage Control of contactors RUN signal Nominal speed Second speeds Inspection speed Second acceleration/deceleration Up/down Reset error CAN communication Emergency Speed limit Contactors Brake Encoder RS-485 communication RUN LED NO. HIGH VOLTAGE 12 13 14 15 16 17 18 19 CAN EM SP K BK ENCODER RS-485 RUN DESCRIPTION OF LED ON: there is a high voltage ON: contactors active ON: start command ON: nominal speed command ON: second set of speeds active OFF: inspection speed ON: second set of accelerations and decelerations active ON: up ON: error reset active Not applicable Not applicable ON: above speed limit ON: contactors active ON: brake with power supply Not applicable Indicator: there is communication ON FIJO: RUN command not active INDICATOR: RUN command active COLOUR Red Red Red Red Red Red Red Red Red Green Green Green Green Green Green Green Green

5.2. Five-digit display (console) See point 6.2. Visualising information through display (monitoring)

POSITION 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

VISUALISATION Frec Encod int s int r Ad in tens Uerr int d int u UEL rEU EiUEL EPUEL An Udd Uud UdE

GENERAL DESCRIPTION Command Frequency (Hz) Encoder pulses Current intensity of U phase (digital units) Current intensity of V phase (digital units) rms output current intensity to motor (Ampere) Bus voltage (Volts dc) Last error Measured Magnetisation Current Intensity (Ampere) Measured Par Current Intensity (Ampere) Measured speed (electric Hz) Measured speed (r.p.m.) Error in Built-in Terminal of speed PI (digital units) Error in Proportional Terminal of speed PI (digital units) Electrical angle Magnetisation component of output voltage vector to motor (digital units) Par component of output voltage vector to motor (digital units) X component of output voltage vector to motor (digital units)

V0.2 MAR.04

Page 9

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
POSITION 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 VISUALISATION UuE SEno CoSE iurEF USlip UrEF Pso Uer SEriE HOurS E4 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 GENERAL DESCRIPTION Y component of output voltage vector to motor (digital units) Sine of electrical angle (digital units) Cosine of electrical angle (digital units) Par current intensity of reference (digital units) Slip (digital units) Mechanical reference speed (digital units) Weight (Kg), if load cell available Software version Equipment serial number Equipment operating hours Start phase Slip term in vector control (machine constant) Reference mechanical speed in Hz*128 Output Iq of the filtered speed PI Electrical frequency Proportional constant of the speed PI Whole constant of the speed PI Weight offset VEL.10 parameter interpretation Maximum torque intensity (digital units) Minimum value of effective intensity in an electrical cycle (digital units) Reference magnetisation intensity Power control set point Electrical frequency offset 1 in stop for torque compensation (Hz*100) Approach speed 1 calculated according to torque compensation (Hz*100) Sine curve time (ms) Machine control variable of torque compensation statuses

V0.2 MAR.04

Page 10

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
6. USER INTERFACE

The user interface is the area where the controller represents the information of its internal state (errors, functioning modes, etc.) and enables the maintainers to carry out a set of operations related to maintenance (configuration, metering, etc.) The interface that the user will find consists of 5 digits which show information and 4 push buttons, as shown in this diagram.

The access keys are: P/R: This push button has different functions, described below: Back or return to previous menu, provided that the user is already inside a menu. Enter Programming Mode. Press button down continuously. Recording of Parameters. Once inside a parameter, this button must be pressed to record it and then exit.

Izq : This push button has different functions, depending on the level reached: At the menu level, it produces a movement to the left At the operations level, it reduces the value being operated At the parameters level it produces a movement to the left between the digits Drch : This push button has different functions, depending on the level reached: At the menu level, it produces a movement to the right At the operations level, it increases the value being operated At the parameters level it produces a movement to the right between the digits

Intro : This push button has various functions: At the menu level, to enter inside the menu At the operations level, execution of commands At the parameters level, increase of value

V0.2 MAR.04

Page 11

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
6.1. Parameterisation The monitoring of the parameterisation is shown below. These parameters are described in detail in chapter 7 of this manual

START
P/R

CUSTOMER CODE

CODE EXAMPLE
P/R

ACCEPTED
1s

GOES TO BLOCKS OF PARAMETERS

P/R

P/R

... EXAMPLE OF ...


VALUE

PARAMETERISATION IN BLOCK CNF-

NEW VALUE
P/R

ACCEPTED AND RETURNED


1s

RETURN TO BLOCK 1 CNF

V0.2 MAR.04

Page 12

3VFMAC-DSP_UK

Provisional

START

P/R Pos. 0 Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5

3VFMAC-DSP FREQUENCY CONVERTER

Pos. 6

Pos. 7

PRODUCT TECHNICAL MANUAL

0.2s
VALUE VALUE VALUE

0.2s

0.2s
VALUE

0.2s

0.2s
VALUE

0.2s
VALUE

0.2s

0.2s

VALUE

VALUE

6.2. Visualising the information through display (monitoring)

Pos. 15

Pos. 14

Pos. 13

Pos. 12

Pos. 11

Pos. 10

Pos. 9

Pos. 8

0.2s
VALUE VALUE

0.2s

0.2s
VALUE VALUE

0.2s

0.2s
VALUE

0.2s
VALUE

0.2s

0.2s

VALUE

VALUE

Pos. 16

Pos. 17

Pos. 18

Pos. 19

Pos. 20

Pos. 21

Pos. 22

Pos. 23

0.2s
VALUE

0.2s
VALUE

0.2s
VALUE VALUE

0.2s

0.2s
VALUE

0.2s
VALUE

0.2s

0.2s

VALUE

VALUE

Pos. 30

Pos. 29

Pos. 28

Pos. 27

Pos. 26

Pos. 25

Pos. 24

VALUE

VALUE

VALUE

VALUE

VALUE

VALUE

VALUE

V0.2 MAR.04

RETURN TO POSITION 0

0.2s

0.2s

0.2s

0.2s

0.2s

0.2s

0.2s

Page 13

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
6.3. PALM control Not available in this version. 7. LIST OF PARAMETERS
ii

F GROUP PARAM SERIES EQUIV.i CNF.00 15 Control Type DESCRIPTION

PERMITS N 2 A 2

FACTORY DESCRIPTION OF VALUES RANGE VALUE

This parameter will determine whether it works in open or closed loop

0: Scale 1:Vector 2:10CV/400Vac

CNF.01

24

Inverter type

Inverter model in terms of power supply and power.

3:10CV/220Vac 4:15CV/400Vac 6:20CV/400Vac

S/M

Maximum no. of errors that may appear in 3 minutes. After this period, the inverter is blocked until one of the following actions is CNF.02 30 Autoreset 2 2 taken: The power supply is cut off -Terminal 19 activated CNF General Configuration CNF.04 N/A CNF.03 N/A Origin of commands CAN monitor Customers CNF.08 N/A access code to parameters Customers CNF.09 N/A access code to parameters Gives information on the installations series CNF.10 N/A Series number Software version Inspection speed 1 1 number. This value is unique for each installation. CNF.11 N/A 1 1 Reports the software version that the machine has recorded. N/A S/P 0...65535 S/P 2 0 2 0 In both, the customers code to access parameters is specified. It is done this way in order not to enter a value accidentally which later makes the parameterisation impossible. 0...9999 0 0...9999 0 2 2 -It enters in programming Specifies whether the origin of the commands will be the terminals or via CAN Specifies whether to activate the monitoring via CAN 0: Terminals 1:CAN 0:NO 1: YES 0 0...5 5

TR0.00

Speed in Inspection Operation (maintenance) Electrical output frequency (scale) or motor

5.00...65.00Hz

15.00Hz

TR0.01 TR0 Travelling. General parameters TR0.02

31

Speed limit

rotation speed (vector), which when exceeded switches the KRL1 relay. A (0 Hz) does not activate RL1 (terminals 30 _ 31 and 32) Enables logic of speed limit relay to be configured. With a positive logic ( 1), the relay will go to ON when the speed is above the set limit and Off when below. With a negative logic

0.00,0.25... ...45.00Hz

0.00Hz

N/A

Speed limit relay logic

(0), The relay will be ON when the speed is below the set limit or is zero, and it will be OFF when it is above the limit. We take speed to mean Electrical output frequency (scale) or motor rotation speed (vector).

0: negative logic 1: positive logic

TR1 Travelling

TR1.00

Nominal speed

Nominal speed 1

10.00...65.00Hz

50.00Hz

V0.2 MAR.04

Page 14

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
F GROUP PARAM SERIES EQUIV.i TR1.01 2 Approach speed Acceleration time Acceleration TR1 Travelling TR1.03 N/A Progressivity Factor TR1.04 10 Deceleration time Deceleration TR1.05 N/A Progressivity Factor 2 2 2 2 2 2 DESCRIPTION PERMITS N A
ii

FACTORY DESCRIPTION OF VALUES RANGE VALUE

Approach speed 1

01.00...15.00Hz

05.00Hz

TR1.02

Acceleration ramp time The higher the value, the smoother the start of the curve and less smooth the end of the curve. Only operational on sine curve (RSN.00 = 2). Value 1 = neutral Deceleration ramp time 1 The higher the value, the smoother the start of the curve and less smooth the end of the curve. Value 1 = neutral

00.30...10.00s

02.50s

0.10...15.00

1.50

00.30...10.00s

02.20s

0.10...15.00

1.00

TR2.00 TR2.01 TR2.02 TR2 Travelling Group 2 TR2.04 TR2.03

3 4 11

Nominal speed Approach speed Acceleration time Acceleration

2 2 2

2 2 2

Nominal speed 2 Approach speed 2 Acceleration ramp time 2 The higher the value, the smoother the start of

10.00...65.00Hz 01.00...15.00Hz 00.30...10.00s

30.00Hz 05.00Hz 01.00s

N/A

Progressivity Factor

the curve and less smooth the end of the curve. Value 1 = neutral

0.10...15.00

01.50

12

Deceleration time Deceleration

Deceleration ramp time 2 The higher the value, the smoother the start of

00.30...10.00s

02.20s

TR2.05

N/A

Progressivity Factor

the curve and less smooth the end of the curve. Value 1 = neutral

0.10...15.00

1.00

RSN.00

N/A

Reverse Curve

Reverse Curve Smoothness at the start of the acceleration ramp. Greater number: Greater smoothness Smoothness at the end of the acceleration ramp. Greater number: Greater smoothness Smoothness at the start of the deceleration ramp. Greater number: Greater smoothness Smoothness at the end of the deceleration ramp. Greater number: Greater smoothness Time in milliseconds of stopping curve

0: Standard 2: Sine 1...999

RSN.01

25

Reverse Curve K End of Acceleration K Start of Deceleration K End of Deceleration Stopping curve time Levelling adjustment

50

RSN.02 RSN Normal reverse ramp RSN.04 RSN.03

26

1...999

50

27

1...999

10

28

1...999

50

RSN.05

N/A

1...3000

0.800

RSN.06

13

Levelling adjustment for load compensation

0..200

100

RSC Short Reverse Ramp

RSC.00

N/A

Extension time on short floor Percentage of

Expressed in milliseconds, this is the time the speed maintains on a short floor Expressed in %. The higher the percentage, the

0...6000

0.000

RSC.01

N/A

increase of command

smoother the speed rectification on a short floor (reducing the approach time)

0...100

50

STC Start/Stop Control

STC.00

22 (T3)

Delay in brake before start Delay in brake before stopping

Delay between order to open brake and start of motor rotation Time between 0 speed and deactivation of brake

00.01...02.50s

00.30s

STC.01

8 (T5)

00.01...02.50s

00.20s

V0.2 MAR.04

Page 15

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
F GROUP PARAM SERIES EQUIV.i STC.02 23 (T4) Delay in brake after stopping Switching STC.03 N/A (T2) waiting time of contactors in start Practical 0 STC.04 STC Start/Stop Control STC.05 N/A N/A speed in stopping. Current intensity value close to 0 Maximum time STC.06 N/A permitted for fall in current intensity Additional time so that residual STC.07 N/A (T6) current intensity is equal to zero. 0 1 00.01...02.50s 0.02s 0 1 00.01...02.50s 1.00s 0 1 1...33 5 1 2 Digit 0, 1: practical 0 speed OFF Digit 2, 3: practical 0 speed ON 00...99cHz 00...99cHz 1 1 00.01...01.00s 00.15s DESCRIPTION PERMITS N 2 A 2
ii

FACTORY DESCRIPTION OF VALUES RANGE VALUE

Time between deactivation of brake and cut-off of motor energy in stopping.

00.01...02.50s

00.50s

00.10

PSO.00 PSO Weight Control

32

Maximum Car Load

Maximum car load in kilograms. Only operational if weight control function is present.

50...3000Kg

10CV: 450Kg 15CV: 630Kg 20CV: 900Kg

Extra par percentage with respect to nominal PSO.01 33 Extra Par % 2 2 applied to maximum load. Only operational if weight control function is present. 0 50 0

ENC Encoder

ENC.00

21

Number of return pulses

Number of return pulses of encoder

4..8, 500...5000

2000

DRI.00

N/A

Motor typeiii Time constant

Defines whether the motor is synchronous or asynchronous. Time constant of the rotor when this acts as the motor

0: Asynchronous or induction

DRI.01

N/A

of rotor as motor Time constant

10.0 1000.0ms

90.0ms

DRI.02 DRI Machine Data DRI.03

N/A

of the rotor as generator

Time constant of the rotor when this acts as the generator Number of poles of motor. NOT NUMBER OF PAIRS OF POLES. Specifies the motor model. In doing so, vacuum current intensity is established, as well as the rotor time and the number of pairs of poles associated to the machine. The value does not last.

10.0 1000.0ms

90.0ms

20

Number of poles

2...50

DRI.04

N/A

Motor Model

0, table codesiv

V0.2 MAR.04

Page 16

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
F GROUP PARAM SERIES EQUIV.i DESCRIPTION PERMITS N A
ii

FACTORY DESCRIPTION OF VALUES RANGE VALUE

10/400: 10.0 A 10/220: 15.0 A 2.0..24.0A 15/400: 12.0 A 20/400: 14.0 A 10/400: 10.0 A 10/220: Gradually increase until correct lift INT.01 N/A Start intensity 2 2 operation is achieved in all load situations (including the maximum). DO NO EXCEED. Only valid in scale control 12.0 A INT Intensity Control The gradient between the output Iq of the speed PI and the Iq of the control system is: INT.02 N/A Iq Filter 1 2 (Iq Speed PI - Iq control system) 2(INT.01) Proportional INT.03 N/A Constant PI Current Intensity Id Built-in INT.04 N/A Constant Id Current Intensity PI Proportional INT.05 N/A Constant Id Current Intensity PI Built-in INT.06 N/A Constant Id Current Intensity PI Percentage of INT.07 N/A Overmagnetisat ion at 0 speed At nominal speed, the no-load intensity applied is INT.00. At speed 0, INT.00+(INT.00xINT.06)/100. NOT VALID IN SCALE CONTROL. 1 2 Expressed in digital units. 0...50 0 1 1 Expressed in digital units. 0...512 1 1 2 Expressed in digital units. 1...2048 150 1 1 Expressed in digital units. 0...512 1 1...2048 150 20/400: 14.0 A 2.0..24.0A 15.0 A 15/400:

Corresponds to the no-load intensity of the INT.00 19 Id 2 2 motor. Normally, do not modify the factory value.

V0.2 MAR.04

Page 17

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
F GROUP PARAM SERIES EQUIV.i Proportional VEL.00 N/A Constant in Start Proportional VEL.01 N/A Constant Nominal Speed PI Built-in Constant VEL.02 N/A Nominal Speed PI 1 2 Expressed in digital units. 0...512 10 1 2 Expressed in digital units. 1...64000 8000 1 2 Expressed in digital units. 1...64000 8000 DESCRIPTION PERMITS N A
ii

FACTORY DESCRIPTION OF VALUES RANGE VALUE

Proportional VEL.03 N/A constant Approx. Speed PI Built-in VEL.04 N/A Constant Approx. Speed PI Built-in VEL.05 N/A Constant Stopping Speed PI VEL.06 VEL Speed Control VEL.07 N/A Measured motor speed filter 1 2 (measured Wmotor W Piw) 2(VEL.06) N/A Reserved 0 0 The gradient between the measured Wmotor and the Wused in speed PI and frequency generation is: 0...10 3 1 2 Expressed in digital units. 0...512 5 1 2 Expressed in digital units. 0...512 20 1 2 Expressed in digital units. 1...64000 15000

Time for the VEL.08 N/A speed stability criterion VEL.09 N/A Approx time established 1 1 1 1

Expressed in milliseconds. Once reached, operates the built-in terminal. Expressed in milliseconds. Only operational when the VEL.10 1 bit is at 1. - If the 0 digit (right) is at 1, a constant Id,Iq,We control will be carried out during approach. Adjusted with 0 value. - If the 1 digit is at 1, a constant Id,Iq,We control will be carried out during stopping. Adjusted with 0 value (activate with low inertia

0...3.000

0.512

0...3.000

0.512

VEL.10

N/A

Control of Speed PI

machine). - If the 2 digit is at 1, the speed PI will only be activated if a new speed has been read. If at 0, it is always activated. - If digit 3 is at 1, the overboost will be activated. If it is at 0, it deactivates. Only operational in magnet vector control.

0 or 1 every digit

1000

V0.2 MAR.04

Page 18

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
F GROUP PARAM SERIES EQUIV.i PEC.00 PEC Power Electronic Converter PEC.01 PEC.02 PEC.03 N/A N/A N/A 14 Switching Frequency Modulation Type Dead Time Minimum pulse width DESCRIPTION PERMITS N 2 A 2
ii

FACTORY DESCRIPTION OF VALUES RANGE VALUE

05.500KHz

5.5 - 20.0KHz. 0: Triangular PWM 1:Space Vector 00.500..03.000s 00.000..03.000s

15.0KHz

2 0 0

2 1 1

Modulation Type Value in microseconds Value in microseconds

1 00.500s 00.000s

ADJ Channel adjustment

ADJ.00 ADJ.01 ADJ.02

N/A N/A N/A

Ir reading gain Is reading gain Vdc 1 reading gain

0 0 0

1 1 1

0...65535 0...65535 0...65535

The numbering begins at 0. Legend of permit types:

ii

N: Normal A: Advanced Permits legend: 0: Not displayed 1: Displayed but value may not be changed 2: Displayed and value may be changed
iii

Synchronous motor not operational. Table of motor models.


MACHINE CONSTANT (ms) 230V 13.9 17.2 18.2 19.1 Motor 79.4 78.4 50.3 51.7 Generator 79.4 78.4 50.3 51.7

iv

CODE

BRAND

MODEL

HP

KW

POLES 400V

IO(A)

100 101 102 103

REIVAJ REIVAJ REIVAJ REIVAJ

075.22.0.30 095.22.0.60 130.20.0.90 145.20.0.90

7.5 9.5 7.5 9.5

5.5 7 5.5 7

4 4 6 6

8.0 9.9 10.5 13.5

200 201 202 203 204 205

SASSI SASSI SASSI SASSI SASSI SASSI

240095A-WF4 240095A-WF4 240118A-WF4 240142A-WF4 240142A-WF4 240171A-WF4

5.5 8.0 10.0 12.5 15.0 18.0

4 5.9 7.35 9.2 11 13.2

4 4 4 4 4 4

4.7 8.4 9.6 11.2 14.2 15.5

8.1 14.6 16.6 19.4 24.6 26.9

82.3 71.6 90.9 94.3 88.5 95.0

61.7 53.7 68.2 70.7 66.4 71.3

V0.2 MAR.04

Page 19

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
8. DESCRIPTION OF ERRORS
ERROR Err01 DESCRIPTION Not used Working situation detected in which the motor instantly consumes a higher current intensity that the maximum offered by the installation. Always caused by external causes, Err02 Overcurrent which are usually serious problems: badly connected power cables, faulty connector, encoder with specific reading errors, too sudden acceleration or deceleration, Machine flywheels with high inertia, etc. Check the power supply being applied to the Maximum voltage permitted by Err03 High network voltage installation exceeded: 400 Model: Maximum 440Vac 220 Model: Maximum 242Vac installation. EXCESSIVELY HIGH VOLTAGE CAUSES THE DESTRUCTION OF THE INSTALLATION. IF 400 Vac ARE APPLIED TO THE INSTALLATION, IT WILL BE TOTALLY DESTROYED Lower voltage than minimum voltage permitted by the installation Err04 Low network voltage applied: 400 Model: Minimum 360Vac 220 Model: Minimum 195Vac Check the power supply being applied to the installation. An excessively low voltage may prevent the installation form starting. Provisional power supply, heavy machinery close to the installation, etc. are possible causes of an instantaneous low network voltage error In general, check that the connections are Err05 Error in encoder The installation detects an incorrect reading of the encoder correct. Check that the correct information has been entered in the ENC.00 parameter. Check that this fulfils all of that described in chapter 3 (manual 3VFMAC1). The most usual causes are: 1. Operating in scale control. This may be due to the INT.00 parameter being excessively low, and when the car is under a heavy load, the lift does not start. The installation has supplied the Err06 Motor blocked maximum current intensity for 6 seconds 2. Operating in vector control. It is possible that it has been configured as vector control and the encoder has not been installed. The installation will consider 0 speed and apply the maximum current intensity. 3. The machine brake does not open. If the car is overloaded and the lift may not start (both in scale and vector control), this error will appear. Locate the error. The repetition of this error may cause the destruction of the installation. If it is not possible to solve it, contact MacPuarsa and describe the error location in detail. CAUSE SOLUTION

V0.2 MAR.04

Page 20

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
ERROR DESCRIPTION CAUSE SOLUTION Consult point 2.3 of the 3VFMAC1 manual to The terminals C1 - C2 must be Err07 Power terminals C1 - C2 not connected shorted (with power cable) whilst energy is supplied. If this disappears instantly, the error will be generated see how the C1 - C2 terminals should be shorted with the K1 and K2 contactors. Check the connections. It is also possible that the power contact is damaged in one of the contactors. This error will appear when a short Err08 Short circuit circuit occurs at the installation output. Try to reduce the approach speed span and operate in vector flow control (consumptions Excess temperature is due to a high Err09 Excess temperature rate working situation, with long approach speed spans, and a high ambient temperature are lower). There is the possibility (although it is unlikely) that the installation ventilation fans become damaged. Check whether these remain off when energy is supplied to the inverter (lift in motion). If so, replace the installation. Motor not connected. There is no Err10 load connected at the output of the frequency changer This may be caused in motors with defects, Err11 Overspeed The motor exceeds 20% of the theoretical speed when there is excess load in the car, etc. The error may also appear if the installation is parameterised incorrectly. No connection to motor. Imbalance. If a connection error appears in one Err12 of the motor stages, or there is a strong imbalance of consumption in the stages, the error will be generated Check the power cables from the output of the frequency changer (U - V - W) up to the motor terminals. Check the correct state of the motor (by measuring the resistance between stages) Check that the network voltage is not too low. If the problem persists, replace the Error in capacitor (10 / 15 / 20 ) or Err13 low network voltage at start of a service Electrolytic Capacitors. VERY IMPORTANT: Before replacing the electrolytic capacitors, MAKE SURE that the HIGH VOLTAGE LED is fully switched off. If not, there is a risk of an electric shock which may cause death Err0A Not used A serious error in the installations Err0B Error in parameters configuration data has been detected. This error may not be reset Err0C Not used Check and correct all the parameters until the error disappears

V0.2 MAR.04

Page 21

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
ERROR DESCRIPTION CAUSE SOLUTION This error usually occurs when during a service, a contact of the safety chain is opened unexpectedly. During a service, the EMERGENCY Err0E Uncontrolled opening of contactors STOP signal (terminal no. 12) disappears; in other words, the K1 and K2 contactors are deactivated unexpectedly This error never renders the installation out of use. This is automatically reset indefinitely. In MACPUARSA controllers, during inspections mode, the series are opened suddenly when a movement is stopped. This causes the FE error to appear after each movement in inspections. The CNF.08 and CNF.09 values Err0d Error in access code (corresponding to the access code) must be the same

9. ADJUSTMENT AND FINE-TUNING OF THE INSTALLATION 9.1. Preliminary aspects Installation of positioning and levelling elements The positioning elements must be installed correctly: speed change pulses (start of deceleration) and levelling. The most important aspect is assuring that the distances between the start of deceleration and the levelling are CONSTANT, such that they are the same for ALL FLOORS. Logically, when the magnets (or shields) are initial installed, the levelling will not be entirely perfect (nor is it necessary), but level differences must not be too acute (maximum of 3 to 5 cm). Remember that a highly inaccurate and unequal installation of the pulse magnets (or shields) and highly inaccurate initial levelling will mean that, after adjusting the parameters (as stated below), the magnets will have to be repositioned, thereby having to repeat the entire adjustment process. Counterweight Before proceeding to adjust the parameters, ensure that the lift counterweight is correct (equilibrium is reached at 50% of the car load). process will have to be repeated. Friction In order to ensure adequate comfort and levelling of the lift, the installation must necessarily be adjusted when the friction (mainly with the guides) is not abnormal. Acute friction, caused by incorrect guide separation distances, may make an adequate adjustment infeasible. Friction with the guides immediately after the lift is installed reduces until it reaches a normal situation after hours of operation. Make an initial adjustment after installing the lift, and subsequently after one month of operation, check to see if it is necessary to slightly alter any parameter. NOTE: These effects are much more acute in lifts with a sling-frame chassis. If the installation is adjusted using an incorrect counterweight, and subsequently the necessary weights for correct equilibrium are added, it is very probable that the adjustment

V0.2 MAR.04

Page 22

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
9.2. General adjustments Nominal frequency, tr1.00: adjust the frequency in order to reach the nominal speed of the machine. See the specifications plaque. Approach frequency, tr1.01: Normally at 5.00 Hz for 1 m/sec, and 3.50 Hz for 1.6 m/sec. levelling. On some

occasions when operating in scale control at 1 m/sec., it must be lowered in order to achieve appropriate Initially, attempt to adjust the levelling at a value of 5.00 Hz, and if an acceptable level is not achieved, lower it, down to a minimum of 4.20 Hz (only in scale control). No-load intensity, int.00, and start intensity in scale control, int.01: Configure the lift in scale control (cnf.00 = 0), and order it to operate without any load in the car, thereby executing long runs. When it moves at nominal speed, read the int d magnitude. Take the reading while going both up and down. The figure obtained in both cases will be very similar. Enter the LOWER of both readings in int.00 and int.01. NOTE: If, when performing this test, the lift does not start when starting from the highest floor to the lowest floor (service with no load in the car going down), slightly and gradually raise int.01 until it does start. If, after performing the test, the value obtained (for the int d readings) is below what was entered in int.01, do not modify this parameter, and only enter the reading obtained in int.00. Type of comfort curve (S-curve), rsn.00: the 3VFMAC-DSP frequency changer incorporates a new, SINE type of comfort curve system, thereby providing a jerk very appropriate to human physiology. Normally, use this type, thereby setting rsn.00=2 (the equipment originally comes configured with this value). adjustments that are described below in this chapter are for this type of SINE curve. In the hypothetical case that you want to use the classic S-curves (MP ASITRON frequency changer), set rsn.00=0, and appropriately adjust the parameters, rsn.01, 02, 03 and 04 (parameters that in the sine type are NOT operational). Number of pulses per encoder revolution, enc.00, and number of motor poles, dri.03: If operating in vector control (cnf.00 = 1), ensure that these two parameters have the correct values. Switching frequency, pec.00: If operating in vector control, set the frequency at 15.0 kHz; the electrical hiss will thus disappear completely. Operating in scale control, the maximum value is 10.0 kHz. The equipment automatically sets the frequency at this value when configured in scale control, such that if it is subsequently placed in vector control, the frequency will have to be modified and raised to 15 kHz. Acceleration time, tr1.02, and acceleration progressivity, tr1.03: The criteria to observe for adequate adjustment is to obtain a good comfort level. From the factory, the values are tr1.02 = 2.5 and tr1.03=1.5 (which are normally appropriate). By increasing tr1.03, the start of acceleration is smoother and the end of acceleration is quicker. NOTE: This parameter (tr1.03) is only operational with the S-type sine curve (rsn.00 = 2). Deceleration time, tr1.04, and deceleration progressivity, tr1.05: The criteria to observe for adequate adjustment is to obtain a good comfort level and to ENSURE an approach speed span (slow) of at least 1 to 2 seconds before levelling. When working in vector control (cnf.00 = 1), an E will appear in the left-hand digit All other

V0.2 MAR.04

Page 23

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
in the FrEC information (where the set point frequency is represented at all times) when the speed is stabilised. During the approach, the E must appear at approximately 1 to 2 seconds. The factory values of deceleration time and progressivity are tr1.04 = 2.2 and tr1.05=1.0, respectively, values that are normally appropriate. Adequately readjust tr1.04 in order to achieve the aforementioned 1to 2-second approach speed. Slowly and gradually reduce tr1.05 in order to smooth out the final deceleration area (just before reaching the approach speed), thereby simultaneously making the start of deceleration quicker. 1 floor (or short floor) service, rsc.01: On occasions, the nominal speed is not reached in a service, either because the floor is especially short or because it is not reached in service between contiguous floors (i.e., in 1.6 m/sec., or in 1 m/sec. lifts that work with large deceleration spans. Whenever this circumstance occurs (it will be noted because the nominal frequency will not be reached in FrEC), the rsc.01 parameter must be adjusted. It leaves the factory with a value of 50. It should be adjusted such that, by executing the service from floor to immediate floor, the (slow) approach speed span that is obtained before levelling is from 2 to 3 seconds (in vector control, it will be noted by the appearance of an E in the first digit of the FrEC representation). If rsc.01 is increased, the approach time will be reduced (and vice versa). 9.3. Levelling adjustment NOTES: o o Make the adjustments following the stated sequence. If the process is inverted, it will very difficult to correctly level the lift. During the adjustment processes, it should not be endeavoured to level with the landing exactly. The objective is to achieve a uniform stop point (always the same), regardless of the load and of whether the service is going up or down. At the end, the levelling magnets (or shields) will be moved in order to make the lift stop point coincide with the level of the landing. Adjustment in order to compensate for the car load, rsn.06 The services that must be made in order to adjust the parameter that compensates for the load (rsn.06), shall ALWAYS be made going DOWN, WITH AND WITHOUT A LOAD in the car, thereby starting at the top level and going to an intermediate level (always the same) that is at least two floors from the top floor. After modifying the parameter, the indicated service shall be made (always the same) WITH and WITHOUT A LOAD in the car, thereby confirming if the levelling point coincides in both cases. If operating in vector control (cnf.00 = 1), with both an industrial encoder as well as with magnets, it is normally not necessary to modify the value of rsn.06 (which originally has a value of 100), given that the load is automatically compensated in this mode. In any event, if it were necessary, slightly increase the parameter (i.e., 110 ... 120). If operating in scale control (cnf.00 = 0), it will be necessary to increase the value considerably. Start from a value of 130 to 140, and gradually increase (or decrease) until adequate levelling is achieved, both with and without a load in the car. NOTE: Prefect levelling is not achieved in scale control (as it is in vector control), wherefore deviations of +/- 1 cm must be allowed. If this is not achieved, slightly lower the approach speed, tr01.01, but do not adjust to values below 4.2 Hz. Only lifts with very reduced and regular friction levels allow an adjustment of the approach speed below 4.2 Hz while operating in scale control.

V0.2 MAR.04

Page 24

3VFMAC-DSP_UK

PRODUCT TECHNICAL MANUAL 3VFMAC-DSP FREQUENCY CONVERTER

Provisional
Levelling in up and down, rsn.05 The services that must be performed in order to adjust the parameter that allows levelling at the same point in both up and down (rsn.05) shall ALWAYS be WITHOUT A LOAD in the car and have an intermediate floor (ALWAYS THE SAME) as the destination floor, thereby starting in one case from an upper floor (down testing) and in the other case, starting from a lower floor (up testing). The origin and destination floors shall be at least two floors distant. After each modification of the parameter, the two indicated services shall be performed (always the same as regards the destination and objective floors, and without a load in the car), thereby confirming if the levelling point coincides in both cases. If, in the down service, a stop point is obtained that is higher than the one obtained in the up service, slightly and gradually increase rsn.05 (i.e., from 0.800 to 0.850). If, in the down service, a stop point is obtained that is lower than the one obtained in the up service, slightly and gradually lower rsn.05 (i.e., from 0.800 to 0.750). Repositioning the level magnets (shields) The prior adjustments allow making the lift stop at the same point, with and without a load, in up and down. Now, this point (already uniform) must be made to coincide with the landing level. To do so, appropriately move the magnets (shields) that determine the levelling point of each floor, thereby correcting the deviations that exist at each stop. NOTE: If the modification in any case is greater than 5 cm, the deceleration start points will have to be modified (pulse magnets or shields) so that the deceleration and approach span to each floor is kept constant. 9.4. Vibrations If there are considerable vibrations during the (slow) approach speed, try to reduce them by taking the following actions: Modify vel.03; vibrations are normally reduced by raising its value. Modify dri.01, if there are vibrations going down, with one person in the car Modify dri.02, if there are vibrations going up, with one person in the car.

If they persist, contact MP.

V0.2 MAR.04

Page 25

3VFMAC-DSP_UK

MACPUARSA
Leonardo da Vinci, s/n, Parc. TA-13 41092 - SEVILLA - ESPAA
ASCENSORES

Tel.:+34 954 630 562 - Fax:+34 954 657 955

Customer Dates
Customer : Nombre Cliente : Ref. Cliente. : Ref. MAC. Y/Reference O/Reference

Features
Universal Down Selective Encoder Imanes Industrial encoder Full Selective Up Selective Simplex Duplex Triplex Cuadruplex

MicroBASIC

N of stops: 10

P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 Sequence: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Motor/Central
Hydraulic direct start 2 Speed 3VFMAC1 OMRON Hydraulic delta/star start Frecuency: Soft starter 50 Hz Power/Voltage 10 CV / 400 V

1 Speed

Comments
* Machineroomless Lifts (SCM).

ASCENSORES

General table of contents


Page
8

Contentsssd

1 2 3 4 5
7 General table of contents

Presentation General table of contents Quality control certyficate Components abbreviation definition Filters. Power connections Controller tranformer Main contactor
Nombre Cliente 10 CV Down Selective. Simplex. 3VFMAC1 (ASCM) Controller Technical department 24.Feb.2003
Technical Department

6 7 8
/ 400 V MAC 27.Feb.2003 Name Date Modified Made Approved AGC

9 10
6

Safety series Battery Speed governor Industrial encoder Auxiliary relay contact.
Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

11 12 13 14 15 16 17 18 19 20 21 22 Single-phase operator Tree-phase operator Cam signal operator. Telephone Change 2C/1H Change 2C/2H Change 1C/1H Mac magnetic switch325. Shaft and car ground. Inspectin box. Car calls connectors. Lighting. upper/lower terminal stopping switch. stop Landing calls connectors. Lightins WEIGHT CONTROLLER

23 24 25 26 27 28

Ref. MAC.

Client ref.

Ref. Cliente.

29.Mar.2004

Page //

ASCENSORES

QUALITY CONTROL CERTYFICATE FOR CONTROL BOARD MACPUARSA


Control driving for electric and oil-dynamic lifts MicroBASIC Ref. MAC.

Manufacturer's name: Type of equipment: Model no.: Serial no.:

1. Electric connections were installed according to project. 2. Symbols of clamps and devices corespond with symbols in electric scheme. 3. Section and type of used wires corespond with the one in project. 4. The state of isolation of electric circuits and device as well as shock protection fulfill the requirements of obligatory rules. 5. Device realizes correctly all expected functions. Symulation of operation states ended with positive result.

In the manufactoring there is quality system type ISO-9001.

Elements of a/m control board were manufactured and assembled according to conditions of Office of Technical Inspection decision no. UDT-017/4 dated 16.06.1993, 12.12.1997 and 12.09.1999.

Place: Sevilla

Signature:

Date:

29.Mar.2004

Francisco Jose Lora Caballero Quality departament

MAC-PUAR,S.A.

C\ Leonardo da Vinci, s\n - Parcela 41092 SEVILLA SPAIN Tel.: +34 95 463 05 62 e-mail: macsa@macpuarsa.es

TA-13.

Polg. Ind. El guila, Ctra. de Logroo Km. 13,400 50180 Fax.: +34 95 465 79 55 Utebo ZARAGOZA SPAIN Tel.: +34 97 678 82 61 - Fax.: +34 97 678 81 53 e-mail: puarsa@macpuarsa.es

Components abbreviation definition


BO: Landing push-button panel connector CAC:Car lighting connector CAF: Pit power supply connector CAH: Shaft lighting connector CAR: Inspection box power supply connector CB: Car push-button panel - inspection box connector CB1: Car push-button panel - controller connector CC1: Car connections 1 CC2: Car connections 2 CC3: Car connections 3 CCA1: Car auxiliary connector CCTF: Controller panel - inspection box telephone connector CCS: Overload and complete connector CF: Magnetic switch / photoswitch connector CH1: Shaft connections 1 CH2: Shaft connections 2 CHA: Landing auxiliary connector CHTF: Pit telephone connector CR2: Inspection box-controller connector CR3: Door operator connector CRA1: Inspection box auxiliary connector CRTF: Inspection box telephone connector CTS: Pit stop connector C1: Fan supply C2: Digital inputs.Control box signal connection C3: Magnets encoder connection C4: Relay outputs C5: Series communication C6: Industrial encoder connection ENC: Encoder conector LA: Lighting power supply LF: Power supply switch ML2D: Load control connector P1: MicroBASIC PCB connector P2: MicroBASIC PCB connector P2: MicroBASIC PCB connector P3: MicroBASIC PCB connector RB: Shaft light connector RB': Top car light connector SMF: Machine room connectore. Power wiring.

SMM: Machine room connectors. Control wiring TS: THERMAL PROBE CONNECTORS: XAFI: Lower stopping limit switch connector XAFS: Upper stopping limit switch connector XCE: Landing door lock connector XCT: Hatch contact connector

XFC: Final switch connector XCTS: Shaft stop connector XCTL: Limiter cable tension contact connector XLV: Speed limiter contact connector XCS: Doors series connector XCA: Outside locks series connector

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Components abbreviation definition

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

TYPE A FILTER
BLACK BLACK

TYPE B FILTER

TYPE C FILTER
Orange(-) (-)

TYPE D FILTER
GREEN

FV VALVES FILTER
BLACK

BLUE

BLUE

PINK

BLUE

*1 1

*2

R1
220 Ohm 2W 2

R1
220 Ohm 2W 2

R1
220 Ohm 2W 2 1

RED(+) +)

RED

1
UF-3010 PANJIT

V1
UF-3010

V1
2
PANJIT

V1
UF-3010

V2
UF-3010

V3
UF-3010

V4
UF-3010

PANJIT

PANJIT

PANJIT

220 Kp 400V

100 Kp 400V

CONTACTOR COIL FILTER CONNECTION

TRANSFORMER FILTER CONNECTION


110 80 60 48 20 0Vs (-) *1 RESISTENCE (-) *2

CAM FILTER CONNECTION VALVES FILTER CONNECTION

TYPE D FILTER

TRM R1
220 Ohm 2W 2 A1 0Vp 220 380

GREEN PINK YELLOW

470 ohm 220 ohm 100 ohm

220V 110V 60V

RED RED RED

V1
UF-3010

PANJIT

C1

C1

2
PANJIT UF-3010

V1
UF-3010

V2
UF-3010

V3
UF-3010

V4
2
PANJIT

PANJIT

PANJIT

A2 TYPE B FILTER

C1
220 Kp 400V 2

R1
220 Ohm 2W 2 1 2 LE (+) LE (-)

SMM

C1
100 Kp 400V

281

240

PANJIT

k1

206

205

204

TYPE A FILTER

THREE-PHASE OPERATOR FILTER CONNECTION

BRAKE FILTER CONNECTION

1 TYPE B FILTER

1 TYPE C FILTER

R1
TYPE B FILTER 220 Ohm 2W 2 1 2

R1
220 Ohm 2W 2 1 2

R1
220 Ohm 2W 2 1

C1
100 Kp 400V

C1
100 Kp 400V

V1
UF-3010 PANJIT

SMF

SMF

SMF

206(+)

204(-)

1 TYPE B FILTER

R1
220 Ohm 2W 2 1 2

C1
100 Kp 400V

SMF
Name Made Modified Approved MAC
Technical Department

W Down Selective. Simplex. 3VFMAC1 (ASCM) Filters.

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

3VFMAC1
R S T +CE -CE B1 B2 U V W C1 C2

PCB

+CE

-CE

B1

B2

C1

C2

OUTPUT
L3 L2

FILTER

INPUT FILTER
L1 L2 L3

L1

(+)

C1
(-) 2200F 400Vdc

R1
2 2W 220K

K1
8.4

L1 T1

L2 T2

L3 T3

DISTRIBUTE
Brown Black PE White

TO ALL EARTH CONNECTIONS SM


B1 B2

K2
8.4

L1 T1

L2 T2

L3 T3

(+)

RF
B1 B2

C2
(-)

R2
2 2W 220K

SMF

SMF
4 mm

PE

PE

2200F 400Vdc

4 mm

4 mm

6 mm

40 Ohms/1040W
M1

W PE

PE

QF
16A a(10CV) Curva C R R S S T T N

PE

FF
25A 300mA white/blue

L3/7.0 L2/7.0 T/15.0 N/15.0


Condenser L1 L2 L3 N PE Brake resistance Main switch

6 mm Power supply switch 6 mm

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 09.Sep.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Power connections

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

2000 tms thermal probe


A1

KRFR
13.6

6 8

RL1
A2

TS

110

80

60

48

20

0Vs

KRFR
13.6

3 1 1

TRM
0Vp 230 400 Connect B type filter as shown in page 5

F1
3,15A 2 3 4 1

FF1
3,15A

RL1
7.8

1 2

PE GRF
RECT01 Brake rectifier

~1

~2

TS
+

FF2
3,15A

SMM
13 14

TS1

TS2

K1
8.4

13 14

K2
8.4

BTST
11 14 A1 A2

White

White

Connect brake filter as shown in page 5

MAX. 1A !
RTE
Motor themperature thermistor

1 2

Us

SMM
Black

204 Red

206

0VP Blue

220VP brown

white/blue

QIG
6A General switch 2

Y1
Connect C type filter as shown in page 5 PE +

Ventilator

6.9/L3 6.9/L2 Controller transformer Brake Exhaust fan motor 1 2 7.8 Machine

j(P2)/10.0 L24VDC/8.0 L0VDC/8.0 L110VS/9.0 L20VS/8.0 L0VS/8.0 L220VP/8.0 L0VP/8.0

room temperature

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 09.Sep.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Controller tranformer Thermal probe

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

PCB MICROBASIC 221/22.4 ROPC


3 4 3 2 4

3KRB/9.6

222/22.4 223/22.4

RB
4

RZS
2 2 3 4 2 4 1 3 2 3

FOP
3,15A 2 4

RVR
3

RM
4

RMT1 RET
3 3

ROPA
3

RS
4

RB
2 2 11 4 14

RTM1/9.6 P2 P3

P1

10

13

16

25

26

Green-yellow

C4(35)/13.0 C4(34)/13.0 KRSE


8.5 5 9

KSG
9.5

14 11

K2
8.4

62 61

PE

Pcb microbasic ground

K1
8.4

62 61

KRNS
8.6

12

A2

A2

A2

A2

K1
11 Connect A type filter as shown in page 5 A1

K2
A1 Connect A type filter as shown in page 5

KRSE
MY4N 110Vac Connect A type filter as shown in page 5 A1

KRNS
G2R-2 110VAC Connect A type filter as shown in page 5 A1

7.9/L20VS 7.9/L220VP 7.9/L0VP 7.9/L0VDC 7.9/L0VS 7.9/L24VDC Stuch contactor activation Main contactor Main contactor Sense relay Nominal speed relay

C/13.0 A/13.0 27/9.0 23/9.0 L220VP/11.0 L0VP/11.0 L0VDC/10.0 L0VS/9.0 L24VDC/10.0

13 53 61 83 L1 L2 L3 Name Made Modified Approved MAC


Technical Department

14 7.313 54 13.153 62 8.161 84 14.8L1 T1 6.8L2 T2 T3 6.8L3 6.8

14 7.4 54 13.1 62 T1 T2 T3 8.1 6.7 6.8 6.8

5 8

9 8.3 12 13.3

11 21

12 8.2 24 13.1

Date 24.Feb.2003 25.Jun.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Main contactor

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

PCB MICROBASIC
PIN 103 6 PIN RME 1

8.9/3KRB 8.7/RTM1

RZS
8

RMT
7 5

2 4 6

RMP FM
2A 8

RMT2
3 5

RPA
1 6

RZS
7

P1

15

12

CC2

102

220

CH2

220 Black

103

104

CC2

00

P3

17

24

23

CH2

105

CC2

105

106

P3

27

travelling cable

travelling cable Green Brown Black 0.75 mm

SM SEM

EM1 1 2

EM2

0.75 mm XLV

CR2

102

220

Black XCA

SLVH
Speed limiter contact 1 2 XLV

CR2

105

106

XCTS 1 3

Machine gear contact for emergency rescue system.

STOPF
Landing stop buttom 2 4 19.5

SCE
XCA PE XCA

Level P1

SAC
Safety gear 2 1

XFCS 1

XCTS

SCC

SEC2
Car door look contact 2

SFS
Upper final limit switch 2 XTL XFCS 1

SCE
XCA PE XCA

Level P2

PE

SEC1
Car door look contact 2 XFCI 1 2

STLH
Pit limiter 1 cable tension contact 2 XFCI 2 XTL

SAF
Slack rope switch

SFI
Lower final limit switch 2 1

SCE
XCA PE

Level pn

SPRB
19.3

3 4

SPRS
19.3

3 4

STOP SIR
19.2 19.3 Inspection push-button stop

A1

KSG
G2R 110Vac Connect A type filter as shown in page 5 A2

Number of stop refered to order

Components in inspection box


7.9/L110VS 8.9/L0VS 8.9/23 8.9/27 Car safety series Shaft safety series

11

14 8.1 Outside locks series Car locks series

Safety series relay

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Safety series

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

PCB MICROBASIC
B D F

External wiring
J K I G H 18 19

Serial interface
T1 T2 20 21 22 31 32

P2

P3

18

19

P4

T1

T2

P3

20

21

22

31

32

RVAR
36V 1 Black Red

F3
2A

BAT
12V 1,3A/h

KRL/19.0 F/14.0 D/14.0 B/14.0


7.9/j(P2) 8.9/L24VDC 8.9/L0VDC

L24VDC/12.0 L0VDC/12.0
Varistor Battery

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 18.Abr.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Battery

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

10

Speed governor

ALJO

Mod. 2129 ESA2/ED

A1 A2

CHA1

RL2

RL1

CRL

OFF

TURNING THE KEY

OPERATION

SIGNAL SALV

CLOCKWISE ANTICLOCKWISE

TRIP RESET

RL1
Overspeed

RL2

gobernor controller

F1 2A

8.9/L0VP 8.9/L220VP

L220VP/14.0

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Speed governor

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

11

3VFMAC1
1 2 3 4 5

LIKA I58-H-2000-ZCU-48RL7
C6
1 2 3 4 5

5Vdc 0Vdc C1+ C1C2+ C2White/Grey

Red black Yellow blue Green Orange Not to connect

24VDC

0Vc

0Vc

5VDC

STEGMANN
5Vdc 0Vdc C1+ C1C2+ C2-

QD6L75JO
12 10 5 6 8 1 Grey White Pink Brown Green Yellow

Orange

Orange

Black

Red

STEGMANN
ENC
+ PE C1+ C1C2+ C2-

HG-660
Red blue White Brown Pink Black

PE

cable braided and shielded

5Vdc 0Vdc C1+ C1C2+ C2-

PE + C1+ C1C2+ C2-

HOHMER
Channel 1 Channel 2

Industrial encoder
10.9/L24VDC 10.9/L0VDC

5Vdc (Vcc) 0Vdc (GND) C1+(A+) C1-(A-) C2+(B+) C2-(B-)

Red Black Yellow Brown Green blue

L24VDC/13.0 L0VDC/13.0

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 25.Jun.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Industrial encoder

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

12

3VFMAC1

External wiring

3VFMAC1
2

External wiring
3 1

3VFMAC1

External wiring

11

12

14

15

16

17

18

13

RL2
1

RL3
2

T1

T2

C2

11

12

14

15

16

17

18

13

C4

33

34

35

36

37

C5

T1

T2

Braided

Braided
53 54

K1
8.4

KRNS
8.6

24 21

KRREV
19.4

12 11

KRSE
8.5

KRFR
12 MK2P 24Vdc 7

K2
8.4

54 53

8.9/C 8.9/A 8.4/C4(34) 8.4/C4(35) 12.8/L24VDC 12.8/L0VDC

T1/14.0 T2/14.0 L24VDC/14.0 L0VDC/19.0 Brake relay

1 6

3 7.4 8 7.3

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 25.Jun.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Auxiliary relay contact.

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

13

VK2P
RS-485

AL-C (FULL)

AL-S (OVERLOAD)

Kg

1 2

4 5 C3 S4

EXC+

EXC-

+IN

-IN

MALLA

T1

T2

C1

S6

D+

D-

0Vac

220Vac

HOLD

HOLD

Green-yellow

White-blue

XPC
PE

+24

91

107

XDSC

D+

D-

Car display MB-D

T1

T2

91

107

216

Orange

CBA1

CBS

CRA2

220VP

INH

travelling cable

travelling cable 2mts

travelling cable 2mts

Load cell CBC1

2mts

T1

T2

CCS

91

107

216

CCA2

220VP

INH

HLSB
Overload light 2

13.8/T1 13.8/T2 10.9/B 10.9/D 10.9/F 11.8/L220VP 13.8/L24VDC

Buzer

F2 2A

K1
8.4

84 83

White-blue

Violet

Orange

Orange

Black

Green

White

Green

Brown

Brown

Mesh

Pink

Blue

Red

Red

Red

0Vcc(CR2)/19.0 L0VP(CR3)/22.2 +24(CB1)/18.0

Serial interface

Full/overload

Car display

NOTE: SEE TECHNICAL DOSSIER VK-2P


Name Made Modified Approved MAC
Technical Department

Date 24.Feb.2003 25.Jun.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

VK2P

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

14

6.9/N 6.9/T

6 mm brown

6 mm brown 1 3 1 3

SALH Y SALC: IN PROTECTION BOX

FA
25A 30mA 2 4

SALH
Shaft light conmutated switch 10A/250V 4 mm brown 4 mm brown 1 3 1 3 1 3 2

CAH CAH

211H

212H

NOA

NCA

211H

212H

NOA

NCA 1.5 mm blue 1.5 mm brown

QAC
10A Car lighting

QAH QASM
2 4 10A Controller lighting 2 4 10A Shatf lighting 2 4

CAH

211H

212H

CA

NOA

NCA

RB

212

211

RB'

212

211

CAM

212

211

travelling cable 0.75 mm 1.5 mm brown 1.5 mm brown 1.5 mm brown 1.5 mm brown 1.5 mm brown 1.5 mm brown

FNH

210H

212H

1.5 mm blue

1.5 mm blue

1.5 mm brown

210C

212C

SALC
5A/250v Car light switch

PE 1 PE 2

XTCA
Controller 211C 212C

CAC CAC

FNA
211 212

210A

212A

protection box power socket

XTCF
Pit

1 PE 1 PE 2

HRB1

1.5 mm blue

HAM RB'
RBF RBN Light

CAA CAC
211 212

211A

212A

SAHF

2 1

3 1

HRB2

HRB'
1

on the machine

R1 travelling cable 0.75 mm

S1

Pit power socket cts

Shaft light conmutated switch

HRBn

2 Shatf lighting in car

XHA1 SHA1
Microswitch up PE 1

IF1

IF2

XF11

211

212

XF12

Shaft lighting

211

212

CAR

211

212

HA1
Light in controler

PE

CAA

211A

212A

R2

R3 S2 S3 211 212

XTCC
Car Inspection box power socket N L

XHA2 SHA2
Microswitch down

IF1

IF2

XF21

211

212

XF22

XF31

211

212

XF32

211

212

HAC
Car lighting HAC

HA2
Light in controler

HA3
Light in controler

1.5 mm 1.5 mm

blue brown

L1/20.0 N1/20.0

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Lightins

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

1.5 mm blue

FNC

15

PCB MICROBASIC
110 111 112

External wiring
113 114 115 116 117 118 119 120 +24 A B C D

CH1

110

111

112

113

114

115

116

117

118

119

120

+24

blue

red

red

red

red

red

red

red

red

red

red

red

SPE P1

3 4

SPE P2

3 4

SPE P3

3 4

SPE P4

3 4

SPE P5

3 4

SPE P6

3 4

SPE P7

3 4

SPE P8

3 4

SPE P9

3 4

SPE P10

3 4

VRE P1
24V

1 2

VRE P2
24V

1 2

VRE P3
24V

1 2

VRE P4
24V

1 2

VRE P5
24V

1 2

VRE P6
24V

1 2

VRE P7
24V

1 2

VRE P8
24V

1 2

VRE P9
24V

1 2

VRE P10
24V

1 2

+24(CH1)/17.0 0Vcc(CH2)/17.0 SPE: LANDING CALL PUSH BUTTON View sequence in covert of this document VRE: LANDING CALL REGISTER

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Landing calls connectors.

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

16

PCB MICROBASIC
5 10

External wiring
0VDC 226 228 213 217 218 215 294 214

CH2

10

0VDC

226

228

213

217

218

215

294

214

White-Blue

Violet

Yellow

Black

Violet

AFS AFI
226

228

BO2

213

217

Grey 218 1 1

LAFI
1

LAFS
1

SAFI
24V 2

SAFS
24V 2

VLSH
24V Shaft up light 2

VLBH
24V Shaft down light 2

AFS

+24

0Vdc

AFI

+24

0Vdc

16.8/0Vcc(CH2) 16.8/+24(CH1)

+24(CH1)/19.0

Lower stopping limit switch

Upper stopping limit switch

Shaft indications

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Lighting. Upper/Lower terminal stopping switch. Stop Shaft indications

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

17

PCB MICROBASIC
109 111 112

External wiring
113 114 115 116 117 118 119 120 +24 A B C D

CC1

109

111

112

113

114

115

116

117

118

119

120

+24

travelling cable 0.75 mm

CB1

109

111

112 19.0 19.0

113

114

115

116

117

118

119

120

+24

Black

Black

Black

Blue

Red

Red

Red

Red

Red

Red

Red

Red

Red

Red

SPC P1

3 4

SPC P2

3 4

SPC P3

3 4

SPC P4

3 4

SPC P5

3 4

SPC P6

3 4

SPC P7

3 4

SPC P8

3 4

SPC P9

3 4

SPC P10

3 4 +24 A B C D

Red

111(CB1)

0VDC 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

VRC P1
24V

VRC P2
24V

VRC P3
24V

VRC P4
24V

VRC P5
24V

VRC P6
24V

VRC P7
24V

VRC P8
24V

VRC P9
24V

VRC P10
24V

14.9/+24(CB1)

0Vcc(CB)/19.0 +24(CB1)/19.0
Binary position indicator

SPC: CAR CALL PUSH BUTTON View sequence in covert of this document

mod. 633

VRC: CAR CALL REGISTER

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 18.Abr.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Car calls connectors.

Ref. MAC.

Client ref.

Ref. Cliente.

Black

112(CB1)

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

18

PCB MICROBASIC
2

External wiring
208 9 0VCC 203

PIN 207

CC2

208

0VCC

203

207

travelling cable 0.75 mm

travelling cable 0.75 mm

wire conect

to 208(CC2)

Identified

Orange

CR2

2 Green

208 Violet

CR2

0Vcc

203

207

A1

Grey

KRL
Orange Black blue Green G2R 24Vdc A2

VRL
A2

Inspectin box

KRREV
G2R2 24Vdc A1

NORM

INSPECTION 3 4

KRL
19.8

11 12

SIR
9.1 Inspection switch

STOP
9.2

3 4

XCTS

208

SPRS
9.1 Inspection up push-button

3 4

STOPF
9.4 Stop of pit

3 4

CLN 1K5

SPRB
9.0 Inspection down push-button

VNIVEL
4

SSEN
Door sensitivity switch

XCTS
Red

+24

Level led

CLN CB
9BB 0Vcc

CB

PAP2

CB

+24

112

111

SPAP
Door opening push-button

207/21.1 203/21.1 +24(CB)/20.0 NC/20.0 COM/20.0

18.2/112(CB1) 18.1/111(CB1) 17.9/+24(CH1) 18.9/+24(CB1) 18.9/0Vcc(CB) 10.9/KRL 13.8/L0VDC 14.9/0Vcc(CR2) Inspection relay Level led 11 12 13.2 11 12 19.8

0Vcc(CR2)/20.0

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 25.Jun.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Inspectin box.

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

19

PCB MicroBASIC
217 218

External wiring
T T

CC2

217

218

CH2

travelling cable 0.75 mm

CAR
SLV
PE

CR2

V1
4

SAL R1
Alarm buttom 3

Green-Yellow

SP
PE

HPLB
6V Emergency Light

SCE
PE

CB

LED+

L+

C-

AL1

AL2

CR2

Box of
Green-Yellow Green-Yellow

Alarm speaker

Inspection
Orange White Brown Brown Pink Blue

H1
Orange 8 Photoelectric 0V

1 0Vac

2 220Vac

Emergency system 222 REV


0V +24 NO COM NC +BAT

F(220v)
0,1A

Fbat
3,15A

<--- Conectar Fotoclula.

+24 cell

PE Car ground

PE Shaft ground

-BAT

OUT

15.9/L1 15.9/N1 19.8/COM 19.8/NC 19.8/0Vcc(CR2) 19.8/+24(CB)

1.5 mm 1.5 mm

brown blue

BAT
6V 750mAh

0Vcc(CR2)/21.1 +24(CB)/21.1

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Shaft/car ground.

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

20

MAC325
Pulses Level

CF

+24

203

0Vdc

207

black

20.8/+24(CB) 19.8/203 20.8/0Vcc(CR2) 19.8/207

Mac magnetic switch 325

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 18.Abr.2003

Controller Technical department

green

blue

red

Down Selective. Simplex. 3VFMAC1 (ASCM)

Mac magnetic switch325.

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

21

PCB MicroBASIC
8.2/221 8.2/222 8.2/223 Open 0Vp Close 0Vp 222 220Vp 221

CC3

0VP

223

travelling cable 0.75 mm

CR3

0VP

223

222

221

orange

blue

red

Black

14.9/L0VP(CR3)

SFCAP
Automatic door opening final limit switch 4

SFCCP
Automatic door closure final limit switch 2

C1
1 2

M2

OPERATOR
PE

Motor monophasic operator

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Single-phase operator.

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

22

PCB MicroBASIC
24.3/221 24.3/222 24.3/223 Open 0Vp Close 0Vp 222 220Vp 221

T S R

Power supply switch

CC3

0VP

223

FR
3,15A

FS
3,15A

FT
3,15A

KCCP
23.3

22 21

KCAP
23.2

22 21

FRTP
23.6 A1 A1

96 95

KCAP
23.2

L1 T1

L2 T2

L3 T3

KCCP
23.3

L1 T1

L2 T2

L3 T3

KCAP
Open door contactor A2

KCCP
Close door contactor A2

FRTP
23.5

CC3'

0VP

237

233

234 238

U1

V1

W1

travelling cable 0.75 mm

Connect three-phase operator filter as shown in page 3

CR3'

0VP

237

233

234 238

U1

V1

W1

orange

orange

grey

grey

orange

Black

red

blue

24.2/L0VP(CR3)

SFCAP
Automatic door opening final limit switch 4

SFCCP
Automatic door closure final limit switch 2

M2

21 L1 L2 L3

22 23.3 T1 23.6 T2 23.7 T3 23.7

21 L1 L2 L3

22 23.2 T1 23.7 T2 23.8 T3 23.8

Tree-phase opertor motor PE

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Tree-phase operator.

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

23

PCB MicroBASIC
23.2/221 23.2/222 23.2/223 Open 0Vp Close 0Vp 222 220Vp 221

CC3

0VP travelling cable 0.75 mm

223

CR3
orange

0VP

223

222

221

Black

23.1/L0VP(CR3)

0Vp

220Vp

red

222

220 vac power supply

220vac cam signal

Door operator control unit

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Cam signal operator.

Ref. MAC.

Client ref.

Ref. Cliente.

REVECO

Cam signal operator

Black 221

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

24

Car telephone

FONOMAC
P25 SAL
20.5

TLF. U37 Controller telephone socket ADAPRJ11


TFN TFN

TFN

TFN

Violet

Violet

Inspectin box telephone socket

CHTF TFN TFN

CCTF TFN TFN

travelling cable 0.75 mm

CRTF

TFN

TFN

red

CTS

TFN

red TFN

Shaft telephone socket

Name Made Modified Approved MAC


Technical Department

Date 24.Feb.2003 27.Feb.2003

Controller Technical department

Down Selective. Simplex. 3VFMAC1 (ASCM)

Telephone

Ref. MAC.

Client ref.

Ref. Cliente.

10 CV

/ 400 V 29.Mar.2004

ASCENSORES

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente

Page //

25

ASCENSORES

Speed =
VEL. ASC m/seg
29.Mar.2004

SFS UPPER FINAL LIMIT 8 SWITCH

Level n

D1

SAFS

D1= 100mm. Level 3


D2

D2<= 100mm.
D3 >=0,4m D3 6 Change 2C/1H

D3 =

DIST FREN mm.

>=3,5m

Level 2
SAFI

10 CV Down Selective. Simplex. 3VFMAC1 (ASCM) Controller Technical department 24.Feb.2003


Technical Department

D4<= 20mm.

D2

STOPPING MAGNET (LEVELLING)


Ref. Cliente. MAGNETIC SWITCH D4 Sounth face Name MAC 27.Feb.2003 Date Modified Made

LENGTH EQUAL TO SUM OF ASCENT AND DESCENT SLIPPAGE. Level 1 D3 MAGNET FOR SPEED CHANGING.
5

DISDISTANCE BETWEEN FLOORS (>=3,5mm)


LOWER FINAL LIMIT SWITCH 4 signal signal SFI Pulse Level

MAC 325

+24

203 0Vdc 207 MAGNET

ABOUT MAGNETS... Sounth face D1 and D2


2

North face

magnets will activate magnetic switches.

Mark

INSTALLATION
INSTRUCTIONS
1

-Guide should be cleaned previously. -Place magnets on guides. -Glue is not neccesary. -Don t install magnets near of speed governor cable.

Approved

AGC

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Ref. MAC.

Client ref.

Nombre Cliente / 400 V

Page //

26

Speed =
VEL. ASC m/seg
UPPER FINAL LIMIT 29.Mar.2004 SWITCH

Level n
D2

SAFS 8

D1

D1=100mm.
!

Level 3

D2<=100mm.

D3 =
>=0,4m D3 >=0,4m D3

DIST FREN mm.

D4>=20mm.

D2 (LEVELLING) LENGTH EQUAL TO SUM OF ASCENT AND DESCENT SLIPPAGE.

STOPPING MAGNET

10 CV Down Selective. Simplex. 3VFMAC1 (ASCM) Controller Technical department 24.Feb.2003


Technical Department

SAFI !

Change 2C/2H

Level 2

SFI LOWER FINAL LIMIT SWITCH MAC 324 MAC 325

(*)

+24

203B

0Vdc

+24

203S

0Vdc

207

Descent pulse signal signal pulse signal

Ascent

Level

MAGNET MAGNETIC SWITCH

! Pay special attencion in the installation of these magnets


ABOUT MAGNETS... South face of D1 and D2 magnets will activate magnetic switches.
2
Mark North face

D4

south face

INSTALLATION
-Guide should be cleaned previosly. -Place magnets on guides. -Glue is not neccesary.
Name 1 Date

INSTRUCTIONS

-Don t install magnets near of speed governor cable. (*) VERY IMPORTANT -F26 and F27 could appear if either magnetics switches or magnets are not correctly installed.
0

MAC

27.Feb.2003 Modified Made Approved AGC

Ref. MAC.

Client ref.

Ref. Cliente.

Level 1 CHANGING.
5

D3 MAGNET FOR SPEED

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955

Nombre Cliente / 400 V

Page //

SFS 9

ASCENSORES

27

UPPER FINAL LIMIT SWITCH

Level n

SAFS

D1

D2 D3 D1= 100mm.

Level 3

>=3,50
Change 1C/1H Nombre Cliente 10 CV Down Selective. Simplex. 3VFMAC1 (ASCM) Controller Technical department 24.Feb.2003
Technical Department

>=0,4 m
/ 400 V MAC 27.Feb.2003 Name Date Modified Made Approved AGC

D2<= 100mm.

D3
6

D3 =
DIST FREN mm.

Level 2 D4<= 20mm.

SAFI

Level 1
LOWER FINAL LIMIT SWITCH signal signal Pulse Level

SFI

D2

STOPPING MAGNET (LEVELLING)

LENGTH EQUAL TO SUM OF ASCENT AND DESCENT SLIPPAGE

DISTANCE BETWEEN FLOORS (>=3,5M)


MAC 325

+24 203 0Vdc 207

MAGNET MAGNETIC SWITCH

ABOUT MAGNETS... South face of D1 and D2 magnets will activate magnetic switches.
2

D4

North face

South face

Mark

INSTALLATION
INSTRUCTIONS -Guide should be cleaned previously. -Place magnets on guides. -Glue is not neccesary. -Don t install magnets near of speed governor cable.

Ref. MAC.

Client ref.

D3
4

MAGNET FOR SPEED CHANGING.

Leonardo da Vinci, s/n, Parc. TA-13 Tlf.: +34 954 630 562 - Fax.: +34 954 657 955 Ref. Cliente.

29.Mar.2004

SFS

Page //

Speed =
VEL. ASC m/seg
9

ASCENSORES

28

ASSEMBLY MANUAL FOR SCM-07 COMPLETE LIFT

Installation Assembly Start-up Use Maintenance Repair


Technical Manual V 0.00, Nov. 03 English / MACSCM07En

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


TABLE OF CONTENTS Chapter 1 RESCUE OF PASSENGERS.......................................................................... 1.1 Procedure for the rescue of passengers in an SCM lift............................................. Chapter 2 INSTALLATION AND ASSEMBLY............... -Introduction..................................................................................................... 2.1 Arrival at the site............................................................................................ 2.2 Unloading materials...................................................................................... 2.3 Lifeline................................................................................................. 2.4 Shaft layout and inspection....................................................................... -Diagram of plumb lines.................................................................................. 2.5 Assembly of side guide brackets............................................................ 2.6 Positioning of bed plate........................................................................ 2.7 Car and counterweight guide rails ...................................................................... 2.8 Assembly of car frame............................................................................. 2.9 Assembly of machine bedframe................................................................... 2.10 Positioning of interlock housing................................................................... 2.11 Assembly of fixed point in beam or wall............................................................... 2.12 Assembly of counterweight frame....................................................................... 2.13 Inserting weights in counterweight frame............................................ 2.14 Assembly of driving ropes ........................................................................ 2.15 Fastening the controller box............................................................................... 2.16 Connecting the terminal box.............................................................. 2.17 Performing the electrical installation of the machine.............................................. 2.18 Assembly of the overspeed governor.................................................................... 2.19 Assembly of the doors........................................................................................ 2.20 Assembly of the car....................................................................................... 2.21 Assembly of the car operator.......................................................... 2.22 Assembly of the SCM-07 lift rescue system ........................................................... 2.23 Assembly of the counterweight buffers and car frame......................................... 2.24 Assembly of the counterweight protection screen............................................... 2.25 Tools............................................................................. Conclusion . Chapter 3 START-UP............................................................................... 3.1 Inspection and testing....................................................................................... 3.2 Car and counterweight....................................................................................... Chapter 4 USE OF THE SCM LIFT......................................................................... 4.1 Purpose of instructions........................................................... 4.2 Intended use of lift.................................................................................. 4.3 Type of controllers............................................................................................. 4.4 Information on the standard use of the lift....................................................... Chapter 5 MAINTENANCE................................................................................... 5.1 Description of components ............................................................................... 5.2 Lift shaft............................................................................................ 5.3 Guide rails....................................................................................................... 5.4 Access doors............................................................................................. 5.5 Ropes.............................................................................................................. 5.6 Machine and bedframe...................................................................................... 5.7 Overspeed governor....................................................................................... 5.8 Buffers................................................................................................. 5.9 Alarm device......................................................................................... 5.10 Rescue system............................................................................................. 5.11 Counterweight.................................................................................................. 5.12 Guide shoes .................................................................................................... 5.13 Safety gear...................................................................................................... 5.14 Batteries.......................................................................................................... 5.15 Load weighing switches ..................................................................................... 5.16 Electrical safety circuits.......................................................................... 5.17 Signs and controllers.................................................................................... 5.18 Controller box................................................................................................ 3 3 4 4 4 4 5 5 6 8 8 9 11 12 14 15 16 16 17 20 21 21 22 23 23 24 24 25 25 26 26 27 27 30 31 31 31 33 35 36 36 37 37 37 38 39 40 40 40 40 41 41 41 41 41 41 41 41

V 0.00, Nov. 03

Page 2/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


Chapter 1 RESCUE OF PASSENGERS
1.1 Procedure for Rescuing Passengers in an SCM Lift

1. Contact the lift technician. The SAFETY DEVICES must always be SWITCHED ON. 2. DISCONNECT THE MAIN SWITCH OF THE LIFT in the top compartment of the controller box next the lift door on the last floor. 3. CHECK THE POSITION OF THE CAR. CALM THE TRAPPED PASSENGERS DOWN and tell them that they are going to be rescued and that the car will move. Tell them not to try to open the doors or leave the car until they have been told that they may do so safely. 4. CHECK THAT ALL THE LANDING DOORS ARE CLOSED AND BLOCKED, AND THAT THE CAR DOORS REMAIN SHUT. Place the OUT OF USE sign at each lift entrance. 5. LOCATE THE FLYWHEEL THAT IS UNASSEMBLED INSIDE THE CABINET AND SCREW IT IN. 6. RELEASE THE BRAKE OF THE MACHINE, VERY SLOWLY PUTTING PRESSURE ON THE FLY WHEEL. Turn this to revolve the pulley manually. CAUTION: It may be necessary to slightly turn the flywheel in both directions whilst pressing down. So that the system meshes fully, the flywheel must be pressed right down to the bottom. WARNING: The car may move up or down alone. In the event of car overspeed, turn the flywheel outwards. If the car is blocked due to the safety gear, or if the car does not move, notify a qualified technician.

7. RELEASE THE BRAKE (TURNING THE FLYWHEEL OUTWARDS) ONCE THE POSITION IS REACHED. THE CAR MUST REMAIN INSIDE THE INTERLOCKING ZONE. The indicator LED, located in the top compartment, indicates whether the car is on the floor level. When you release the brake, once the desired car position is reached, move the flywheel in both directions, making sure that this turns freely. 8. UNBLOCK AND OPEN THE LANDING DOORS WITH THE EMERGENCY KEY to free the passengers (use of this key must be restricted to authorised and trained personnel who are familiar with the rescue procedure). 8.1 LOCATE THE UNLOCKING TRIANGLE IN THE DOOR FRAME. All doors have an unlocking triangle. In MP doors, this is on the door lintel. 8.2 INSERT THE KEY IN THE TRIANGLE, to mesh the mechanism. TURN THE KEY THE APPROPRIATE WAY TO UNLOCK THE DOOR, AND OPEN THE DOOR by applying pressure with your hand on the door edge. 8.3 Once the landing door is open, THE CAR DOOR IS NOT BLOCKED and it may be opened without using the wrench. WARNING: If the car is not quite on the floor level, take special care to protect the passengers when they leave the car. 9. Once the passengers have been freed, make sure that ALL THE DOORS ARE CLOSED AND CORRECTLY BLOCKED, leaving ALL DEVICES AND DRIVES OF THE RESCUE SYSTEM IN THEIR INITIAL POSITION. 10. NOTIFY THE TECHNICAL SERVICE so that the lift is checked before being put into use again. WARNING: The lifts power supply must remain off until assistance from the Technical Service.

1.2 Procedure to open the landing doors with the emergency key.
In the event of an emergency, in order to gain access to the shaft or to the car, you must use the unlocking key for the landing doors. For safety reasons, the use of this key must be restricted to authorised and trained staff who are familiar with the rescue procedure. WARNING: If it is necessary to open the landing door to establish the cars position or to free the passengers, take extra care to avoid falling into the shaft. Do not leave the landing doors open unless the entrance is suitably protected and secure, to avoid anyone falling into the shaft. 1. LOCATE AND HAVE THE UNLOCKING KEY READY. 2. DISCONNECT THE MAIN LIFT SWITCHES, WHICH ARE IN THE CONTROL CABINET. 3. LOCATE THE UNLOCKING TRIANGLE IN THE DOOR FRAME. All doors have an unlocking triangle. In MP doors, this is on the door lintel. 4. INSERT THE KEY IN THE TRIANGLE, TO MESH THE MECHANISM. TURN THE KEY THE APPROPRIATE WAY TO UNLOCK THE DOOR. 5. AT THE SAME TIME, OPEN THE DOOR BY APPLYING PRESSURE WITH YOUR HAND ON THE DOOR EDGE. 6. ONCE THE LANDING DOOR IS OPEN, THE CAR DOOR IS NOT BLOCKED AND IT MAY BE OPENED WITHOUT USING THE KEY.

V 0.00, Nov. 03

Page 3/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


CHAPTER 2 INSTALLATION AND ASSEMBLY
EVERYTHING DESCRIBED IN THIS POINT REGARDING SAFETY IS DONE SO IN GENERAL TERMS. AS WELL AS THIS MANUAL, YOU MUST ALSO AT ALL TIMES CARRY THE OCCUPATIONAL HEALTH AND SAFETY MANUAL, WHICH DESCRIBES THE SAFETY MEASURES IN GREATER DEPTH.

Compulsory foot protection

Compulsory head protection

Compulsory hand protection

Welcome to the manual on the installation and assembly of the SCM-07 model of the range of MP lifts, which fulfils all the safety requirements of the European Directive. MPs SCM series stands out in that it saves space since it is machine-room-less, and is able to use these metres for any other architectural use. This assembly manual will guide you through the steps of the lifts installation and assembly process. This process is based on the methods, techniques and tools proposed by MP for the quick and safe installation of the lift.

Introduction:

2.1 Arrival at the Site


When on site, a safety helmet must be worn at all times, to protect from falling objects. Also use boots with the sole protected from sharp objects, and the top toe area reinforced with metal to protect from knocks and crushing due to falling heavy materials. The shaft must be clean and free of obstacles, with the accesses protected from falling objects and persons, and built in accordance with the drawing specifications. Make sure that there are hooks in the overhead of the shaft which are necessary for the assembly and lifting of loads, which are installed by the manufacturer. There must be a three-phase and single-phase power supply, as well as an area for storing materials as close to the shaft as possible.

2.2 Unloading Materials


When unloading materials, for materials weighing more than 25 kg, always use the lifting equipment that is available on site (fork-lift trucks, pallet carriers, cranes, hand carts, etc, ). When lifting heavy loads, use neoprene lumbar belts to prevent back injuries. Materials must be unloaded on site by one or several workers from the installation company, assisted by site personnel, who shall provide the suitable resources to facilitate loading work and material distribution. For distribution and storage, the following must be taken into consideration: 1.

2. 3. 4.

That the materials are as near to the shaft as possible. That they are in an area where neither water nor debris may fall, and away from machines that may create dust. That they are not in a thoroughfare area and that their storage does not present a danger for persons if they fall. The receiver of the material shall check the received material against the material that appears on the shipping chart, counting it and checking the most important elements, such as: Distance between car and counterweight frame guide rail. Machine and bedframe. Number, type and gripping mechanism of the doors. Number and type of car and counterweight guide rails. Number and diameter of driving ropes and overspeed governor. Number of rope attachments. Number and type of car and counterweight guide shoes. The guide rails shall be supported on three points to avoid buckling. If this has to be left on a finished floor, place some kind of material underneath (paper, plastic, etc) to avoid staining the floor with the grease from the guide rails. When inserting the guide rails in the shaft, rest the bottom part on the front of the pit, and the top part in the rear corners of the shaft. Leave the doors in a safe place, where there is no danger of them falling or becoming deformed. If possible, distribute them on the floors with the aid of a crane. The traction or driving assembly shall be discharged with the bedframe on the last floor of the installation. If for any reason material must be left outdoors, which must be avoided at all costs, cover it with plastic so that does not get wet. Do not leave it directly on the floor, but on pallets, bricks, planks, etc. Do not rely on the plastic covers that come with the material from the factory. The car must never be left outdoors, since water and damp may damage it significantly.

V 0.00, Nov. 03

Page 4/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.3 Lifeline
The first operation to be performed inside the shaft shall be to install the lifeline, prepared to bear the weight of two persons, and hooks in each one of the shaft accesses. At the same time, strap on the safety belts. These operations will also be performed secured to a fixed point of the installation.

2.4 Shaft Layout and In


Compulsory personal protection against falls

2.4 Shaft layout and inspection.

Compulsory foot protection

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

CAUTION
Protect yourself from objects that may fall through the shaft, and from falling into gaps Use safety protection when drilling, welding, cutting and driving nuts and screws To climb down to the pit use a ladder

Use the tools prepared for this purpose, positioning them in the shaft in accordance with the drawing of the installation and plumb lines. Once the ropes have been cast, check each one of the x-y shafts floor by floor to ensure the minimum measurements indicated in the plan view drawing.

It is essential that you carry the LAYOUT AND ELEVATION drawing of the installation 2.4.1 Proceed to the shaft layout and inspection.

ATTENTION

1. 2. 3. 4. 5.

6.

The first step in the assembly of the SCM-07 lift is the checking of the width and depth of the shaft. Begin the layout process from the overhead area of the lift shaft, fastening the set square to the shaft wall, at a height of 1300 to 1500 mm from the floor level of the last floor and as close as possible to the car opening. Loosely fasten the tube to the set square, until you have checked this. Through each one of the sides of the shaft, cast the plumb lines until they almost reach the pit; the top layout system will predetermine the position between them. Once the plumb lines have been cast, work with the minimum distances marked on the plan view drawings or the drawing in perspective shown below. Check the shaft floor by floor, and if it is OK, fasten the bottom plumb line tool to preset the position of these (fasten the tube to the set square of point 3). If this is not OK, adjust the ropes from the last floor, releasing the tube from the set square, to make it possible to adjust in all directions. Having preset the plumb lines to locate the guide rails, cast a rope with colouring from the preset position on the top tool, making a mark along the entire length of the shaft which must match the groove of the closest bracket to the car opening.

THE FOLLOWING PAGES SHOW THE LAYOUT OF BOTH DISTANCES BETWEEN GUIDES,. I.E. ONE PLAN VIEW DRAWING AND ONE DRAWING IN PERSPECTIVE.

V 0.00, Nov. 03

Page 5/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift

2.4.2 Diagrams of plumb lines.

E.G 1500 plumb line layout

E.G 1200 plumb line layout

PLAN VIEW OF LAYOUT E.G 1500

CLOSE-UP A, 2:1

V 0.00, Nov. 03

Page 6/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift

E.G 1500 E.G 1200

A 1500 1200

B 800 500

C 350 350

(1) Distance X (depends on shaft dimensions) + Distance C (2) Position rope 1 + distance B (3) Predetermine position by system PHOTOS OF TOP AND BOTTOM LAYOUT TOOLS:

TOP LAYOUT TOOL

BOTTOM LAYOUT TOOL

V 0.00, Nov. 03

Page 7/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.5 Assembly of guide brackets.

Compulsory head protection

Compulsory foot protection

Compulsory personal protection against falls

Compulsory hand protection

SEE INSTALLATION MANUAL, SUPPLIED WITH SHAFT COMPONENTS


1. 2. 3. 4. 5. 6. 7. Following the distances indicated in the elevation drawing of the installation, position the brackets, starting with the first length of guide rails. The first bracket shall be positioned in the closest area to the car opening. Take special care when matching the stain mark, obtained in the previous step of the assembly process, with the groove in the middle of the bracket. Check the right level of the bracket, both on the vertical and horizontal planes. The second bracket shall be positioned levelled and at a distance of 1200 or 1500 mm, which will always coincide with the distance between guides of the installation. Then, assemble the bracket arms without tightening them, in order to facilitate the later positioning of the guide rails. Having completed all of the brackets, make sure that they are all at the relevant height and levelled both vertically and horizontally.

PLUMB LINE WITH COLOURING

COMPLETE BRACKET

FASTENING OF BOTH BRACKETS

2.6 Assembly of the bed plate.

Compulsory foot protection

Compulsory head protection

Compulsory hand protection

SEE INSTALLATION MANUAL, SUPPLIED WITH SHAFT COMPONENTS


Following this, in the pit area, and as a prior step to the assembly of the car and counterweight guide rails, position the bed plate. Position the bed plate without fastening it to the floor for the time being, until the positions of the guide rails with respect to the plumb lines are established.

CAR AND COUNTERWEIGHT GUIDE RAIL BASE PLATES

V 0.00, Nov. 03

Page 8/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.7 Assembly of car and counterweight guide rails

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE PREVIOUS POINT 2.4 Shaft Layout and Inspection 1. 2.


So that the machine always remains in the right position, that is, accessible from the last floor, irrespective of the measurements of each shaft, cut the length specified in the elevation drawing from the counterweight guide rails. If the actual shaft measurements are different to those indicated in the drawing, correct the length to be cut in accordance with the following formula: How to calculate the length of guide rails to be cut. Although THE EXACT LENGTH TO BE CUT IS INDICATED IN THE ELEVATION DRAWING OF EACH PARTICULAR INSTALLATION, how to calculate this is described, and how to adapt the cut if the actual shaft measurements are different to those specified in the drawing. LGC: total length of counterweight guide rails SENT in mm C: Length of section of counterweight guide rails to be CUT F: Height of pit (in mm) R: Distance between the first and last floor 1550*: Set distance at which the machine bedframe is positioned C=LGC-F-1550 THROW A TAPE MEASURE FROM DISTANCE 1550 mm, OVER THE LAST LANDING TO THE FLOOR OF THE PIT. If the length is DIFFERENT to that indicated in the drawing, ADAPT the length of counterweight guide rails to be cut by using the formula. EXAMPLE 1: Distance ACCORDING TO DRAWING from distance 1550 to the floor 15000 Cut ACCORDING TO DRAWING of counterweight guide rails= 200 mm Distance of ACTUAL MEASUREMENT from distance 1550 to the floor=15100 mm ACTUAL MEASUREMENT of counterweight guide rails= 100 mm EXAMPLE 2: Distance ACCORDING TO DRAWING from distance 1550 to the floor=15000 mm Cut ACCORDING TO DRAWING of counterweight guide rails= 200 mm Distance of ACTUAL MEASUREMENT from distance 1550 to the floor=14900 mm ACTUAL cut of counterweight guide rails= 300 mm *NOTE: Set cut for standard pit (1400 mm). For reduced pits, this distance will vary. See individual elevation.

3.

After inserting the guide rails with the aid of a safety harness, begin assembly, always positioning the counterweight guide rails with the sockets (1) facing upwards and the car guide rails with the sockets facing downwards (2) and assembling the guide rail sections measuring different lengths in the order indicated in the elevation plan.

3.1 THE CUT SECTIONS OF GUIDE RAILS MUST ALWAYS BE POSITIONED


FIRST.

3.2 CLEAN THE GUIDE RAILS WITH GREASE REMOVAL LIQUID TO

COMPLETELY ELIMINATE THE WAX ON THE SLIDING PART. 3.3 IF ANY BRACKET MATCHES WITH ANY GUIDE RAIL COUPLING, ASSEMBLE THIS UNDERNEATH.

V 0.00, Nov. 03

Page 9/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


4.
To facilitate the assembly of the guides, a straightedge is supplied, which is fastened in the first section of guide rails, being completely levelled with respect to the layout.

GUIDE RAILS FASTENED BY STRAIGHTEDGES

5. 6.

7.

Having established the position of the car and counterweight guide rails, finish fastening the brackets. In the first section, also fasten the guide rails of the bed plate with through screws in the case of the car guide rails and with flanges in the case of the counterweight guide rails. As a final step, check all the couplings, eliminating the occasional bumps with a body file.

V 0.00, Nov. 03

Page 10/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.8 Assembly of car frame:

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLATION MANUAL SUPPLIED WITH CAR FRAME

This assembly stage shall be performed in the pit area. Take into consideration the distances and measurements that appear in the layout and elevation drawing, regarding its correct position in the shaft. To fasten all the parts, use the suitable tools, taking special care when positioning the slings in the corners of the beams of the frame (as shown in the above photograph), in order to lift it with the hoist. ASSEMBLY SEQUENCE:

1.
2. 3.

Assemble the two Ls of the frame (these arrive at the site already assembled, including the wedging boxes), on the car guide rails and fasten them by inserting the top beam. This entire process shall be performed with the aid of a hoist (manual or electric) Position the centre part of the car frame (pulleys). Position the rest of the components of the frame.

L OF FRAME

FASTENING THE LS WITH THE TOP BEAM

4. 5.

Assembly of the scaffold or platform on the top part of the frame With the aid of the hoist, lift the frame-platform and position the rest of the guide brackets (as indicated in the photographs). DO THIS BRACKET BY BRACKET DUE TO THE WEIGHT OF THE FRAME.

V 0.00, Nov. 03

Page 11/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.9 Assembly of machine bedframe:

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLATION MANUAL SUPPLIED WITH SHAFT COMPONENTS

From the overhead area, begin this stage of the assembly by fastening the bedframe brackets on the counterweight guide rails. On these, position the main part of the bedframe, using the steel plates of different thicknesses if off-level. Having completed this step, fasten the arms to the main part of the bedframe and the set squares and brackets to the arms. The brackets must be attached to the car guide rails with fastening flanges. Next, assemble the fixed point in the bedframe. Continuing in the overhead area, and using the lifting system installed in the top part of the shaft, hoist the machine to its position on the bedframe. Next, fasten it definitively by screwing it to the main part of the bedframe and fastening it with the auxiliary elements supplied. The assembly sequence is shown on the following page. IMPORTANT: Position the bedframe on the right or left, depending on the layout.

EG. OF INSTALLATION, LAYOUT ON RIGHT, WITH FIXED POINT INSTALLED

V 0.00, Nov. 03

Page 12/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


Assembly sequence of bedframe and machine:
1. Position the seats of the machine bedframe on the counterweight guide rails. 6. Connect the fixed point in the bedframe to the main part of the bedframe. NOTE: Carry out this operation before lifting the main part onto the counterweight guide rails.

2. Connect the main part of the bedframe to the previously positioned seats, using wedges if necessary.

7. Connect the machine to the bedframe

3. Connect the set of arms to the main part of the bedframe

8. Position the reinforcement machine to machine

4. Connect the bracket to the arms (repeat this operation 4 times)

9. Connect the screen brackets to the bedframe

5. Connect the set squares to the brackets (Repeat this operation 4 times)

10. Assembly of protection screen pulley machine to bedframe

V 0.00, Nov. 03

Page 13/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.10 Assembly of interlock housing.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLATION MANUAL SUPPLIED WITH SHAFT COMPONENTS


After assembling the bedframe, the following step is to position the interlock housing for the car frame. Perform this on the last bracket, located below the bedframe.

The interlock housing shall be connected to the counterweight guide rail by M-12 flanges which are included in the mechanics box. It is extremely important that the two interlock housings are at the same height for the correct actuation of the interlocking locks.

V 0.00, Nov. 03

Page 14/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.11 Positioning of fixed point in beam or wall.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLATION MANUAL SUPPLIED WITH SHAFT COMPONENTS


Next, position the fixed point in the driving ropes, which, depending on the layout drawing of the installation, may be; 1- Fixed point in beam: When the space is standard 2- Fixed point in wall: When the space is reduced (less than 80) The measurement that marks the fixed point to be positioned is indicated in the following diagram.

PLAN VIEW OF LAYOUT DISTANCE, WHICH DEFINES THE FIXED POINT IN THE WALL OR BEAM. UP TO 80 mm WALL FROM 80 mm BEAM

CLOSE-UP OF DISTANCE (*), ACCORDING TO LAYOUT DRAWING

- Two possible cases are described below:

PHOTO OF FIXED POINT OF ROPES FROM CAR TO BEAM

FIXED POINT OF ROPES FROM CAR TO CONCRETE WALL

FIXED POINT OF ROPES FROM CAR TO BRICK WALL

V 0.00, Nov. 03

Page 15/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.12 Assembly of counterweight frame.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLAITON MANUAL SUPPLIED WITH COUNTERWEIGHT FRAME

The following step is the assembly of the counterweight frame to the guide rails, since this arrives from the factory fully assembled. Insert this with the aid of a mechanical hoist, on the first length of guide rails.

DRAWING OF COUNTERWEIGHT FRAME, LAYOUT ON RIGHT

EG. OF INSTALLATION, LAYOUT ON RIGHT

2.13 Inserting Weights in Counterweight Frame.

Compulsory foot protection

Compulsory head protection

Compulsory hand protection

SEE INSTALLATION MANUAL SUPPLIED WITH COUNTERWEIGHT FRAME


IMPORTANT: Before positioning the lift in configuration, insert the necessary weights in the counterweight in order to balance the car frame, in accordance with the drawing specifications.

V 0.00, Nov. 03

Page 16/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.14 Assembly of Driving Ropes.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

2.14.1 How to unwind the ropes. The ropes are supplied in rolls or coils. The smaller diameter, flexible and shorter ropes are supplied in rolls, as well as the ropes that are easy to handle. The thick and long ropes are packed in bobbins. There are several ways to unwind a rope, but they must all be carried out carefully, to avoid curling the rope. Curling may cause deformation at certain points that unbalance the rope irreparably. (Fig. A) Although this straightens before assembling the rope, these points have a weak resistance as a result of the deformation, and because there are always ridges left which deteriorate prematurely due to abrasion (Fig. B)

When the rope is supplied wound on a bobbin, to unwind it, place the bobbin so that it may turn freely on an axis resting on two supports. (Fig.C) If the rope is packed in a roll, this is undone by rolling it forward so that the turns are unwound without distortion. (Fig.D) If the rolls are heavy and large, and difficult to manage by hand, it is better to place the roll on a support in the form of a wheel, and turn the roll on this. (Fig.E).

Fig. A

Fig. B

FIG. C

FIG D

FIG E

If these recommendations are not followed when unwinding the ropes as shown in figures F and G, a number of acute twists will be caused in the ropes and permanent deformations may appear, or at the least the ropes will become lively and will react irregularly on the devices which support and operate the installation.

FIG. F

FIG. G

V 0.00, Nov. 03

Page 17/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.14.2 Attaching the rope to the rope socket. Firstly, the close-up is shown of how the rope passes through the rope socket and some approximate measurements to attach them properly.

RECOMMENDED DISTANCES FOR THE ROPES (1) Insulating tape (2) Rope clamps (3) Rope Close-up of the attachment of the terminals at the fixed point in the bedframe and the fixed point in the beam.

FIXED POINT IN BEDFRAME

FIXED POINT IN BEAM

2.14.3 Assembly of driving ropes. When starting the assembly of the ropes in the shaft, position yourself in the area of the shaft with the car frame and scaffold assembled on the top part of the frame. Raise this assembly (frame-platform) to the overhead space with the aid of a mechanical or electric hoist. TWO WORKERS must carry out this operation, one at the top of the scaffold (IT IS EXTREMELY IMPORTANT TO WEAR COMPULSORY PERSONAL PROTECTION AGAINST FALLS) and the other worker in the pit of the shaft, in order to pass the ropes up and down with the aid of a cord. The worker at the top of the scaffold shall attach the rope to the rope socket which is positioned at the fixed point in the beam or wall, as shown in the previous point, and drop the rope down to the pit. He shall then go down to the bottom part of the car frame, where the pulleys are located. With the aid of the cord, he shall then lift the rope, passing it through the grooves of the car frame pulleys, and then through the grooves of the machine traction pulley, then dropping the rope again. The worker in the pit catches the rope and is then in charge of passing it through the groove of the deflection pulley of the counterweight frame. Finally, the worker at the top wall catches the rope with the cord and attaches this to the rope socket in the fixed point in the bedframe. NOTE: The ropes shall be attached one after the other. Until the first rope is attached to the fixed point in the beam or wall and to the fixed point in the bedframe, do not assemble the second rope.

V 0.00, Nov. 03

Page 18/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.14.4 Travel of ropes.

SEQUENCE OF PASSING ROPES A- FIXED POINT IN BEAM B- ROPES ENTER CAR FRAME C- ROPES LEAVE CAR FRAME D- ROPES ENTER MACHINE TRACTION PULLEY E- ROPES LEAVE MACHINE TRACTION PULLEY B- ROPES ENTER DEFLECTION PULLEY OF COUNTERWEIGHT FRAME B- ROPES LEAVE DEFLECTION PULLEY OF COUNTERWEIGHT FRAME H- FIXED POINT IN BEDFRAME

THE ASSEMBLY SHALL BE PERFORMED ROPE BY ROPE. THE FIRST ROPE SHALL BE ATTACHED TO THE FIXED POINT IN THE BEAM AND END AT THE FIXED POINT IN THE BEDFRAME

V 0.00, Nov. 03

Page 19/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.15 Fastening the Controller Box.

Compulsory foot protection

Compulsory head protection

Compulsory hand protection

SEE INSTALLATION MANUAL SUPPLIED WITH THE PRE-ASSEMBLED INSTALLATION FOR SCM LIFTS
Fasten this with the brackets supplied, bearing in mind that as a prior step a provisional assembly shall be performed to position the terminal box. CAUTION: Under no circumstances must the controller box be installed in private premises.

1. 2. 3.

The controller box shall be fastened on the landing of the last floor, next to the door frame, so that it is installed with the door. The box shall be located on the machine side with the gripping mechanism on the side of the door in which it is positioned. Before assembling the controller box, the braking resistance must be positioned, as indicated in the preassembled manual. VERY IMPORTANT: This connection will be carried out voltage-free in the inverter. The controller box shall be assembled and fastened in a similar way to the door frames. To see the assembly sequence, consult the pre-assembled technical manual.

ELECTRICAL PART OF CONTROLLER BOX

GENERAL VIEW

V 0.00, Nov. 03

Page 20/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.16 Connecting the terminal box.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLATION MANUAL SUPPLIED WITH PRE-ASSEMBLED SCM


This box, along with the necessary connectors, makes it possible to start up the machine and to use it for the assembly of the mechanical part of the ascent, and in this way, move the car up and down before performing the electrical installation. CAUTION: It will be necessary to supply power to the controller and connect the machine to this.

2.17 Performing the Electrical Installation of the Machine.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

Disconnect the general switches of the installation. Protect yourself from electrical discharges by using tools with an insulator of no less than 1000V. Work clothing must not be made of fabric with plastic components (it is advised that this is made of cotton).

SEE INSTALLATION MANUAL SUPPLIED WITH PRE-ASSEMBLED SCM AND WITH SASSI LEO MACHINE (DISC BRAKE MODEL)
The electrical installation shall not vary much with respect to conventional installation. However, special care must be taken when routing the ropes through the shaft, since this determines the behaviour of the electromagnetic compatibility of the installation, as well as possibly interfering with car or door movement. All of the rope routing and the electrical part are explained in detail in the pre-assembled technical manual.

V 0.00, Nov. 03

Page 21/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift

2.18 Assembly of overspeed governor.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLATION MANUAL SUPPLIED WITH SHAFT COMPONENTS


At this stage of the assembly, install the overspeed governor, which will allow you to move with the lift safely. Begin by assembling the top part of the overspeed governor (see diagram in documentation supplied with this component), located in the overhead area, positioning this in the position indicated in the plan view drawing of the top part of the governor. Then, install the bottom part of the governor in the pit area, as indicated in the installation drawing. Finally, position the governor rope by fastening it to the control lever of the wedging box, which should have been correctly adjusted previously. NOTE: To connect the rope to the frame, see the frame and wedging box manual .

PHOTO OF TOP PART OF GOVERNOR

PLAN VIEW OF LAYOUT OF TOP PART OF GOVERNOR

V 0.00, Nov. 03

Page 22/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift

2.19 Assembly of Landing Doors.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLATION AND ASSEMBLY MANUAL OF LANDING DOORS


Firstly, assemble the car floor, following the instructions included in the load-weighing switch installation manual, the car assembly manual and using the measurements shown on the installation drawing. Once you have assembled the car floor, you are ready to assemble the landing doors. Use the suitable tools for this operation. During the assembly, take special care to follow the instructions of the landing doors assembly manual, as well as to check that each door installed is properly levelled and blocked with the relevant flap lock.

2.20 Assembly of Car.

Compulsory head protection

Compulsory personal protection against falls

Compulsory hand protection

Compulsory foot protection

SEE INSTALLATION MANUAL SUPPLIED WITH CAR 1.


2. 3. Before performing this operation, follow the points set out in Shaft Layout and Inspection. Make sure you recheck the weight content in the counterweight frame. Bear in mind the relevant clearances with respect to the landing doors. Assemble the car, connecting the floor to the frame and continuing the assembly as indicated in the car assembly manual.

4.

TOP CAR FASTENING

V 0.00, Nov. 03

Page 23/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.21 Assembly of Car Operator.

Compulsory foot protection

Compulsory head protection

Compulsory hand protection

SEE INSTALLATION MANUAL SUPPLIED WITH DOOR OPERATOR

During the assembly of the different components and accessories of the electrical part, follow the points set out in Shaft Layout and Inspection and that described in the section on the electrical installation of the machine. This component will be responsible for the suitable opening and closing of the telescopic panels of the doors.

2.22 Assembly of Rescue System of SCM-07 lift.

Compulsory foot protection

Compulsory head protection

Compulsory hand protection

SEE INSTALLATION MANUAL SUPPLIED WITH MECHANICAL RESCUE SYSTEM CAUTION: This assembly must be performed by 2 workers
The mechanical rescue system enables the car to be moved in the event of an emergency, until it is positioned at the height of the nearest landing, which will be indicated by the indicator LED located in the top part of the controller box. At this moment, the passengers may leave the lift safely. This system is comprised of two main subsets, known as the machine subset and cabinet subset, which are connected together by a flexible cable and a metal brake flexible cable. The components that are to be installed inside the shaft shall be assembled from the car roof. IMPORTANT: Carry out all the operations with the counterweight below, near the buffers. The brake flexible cable of the rescue system must always be tightened at the end of the inside of the shaft.

V 0.00, Nov. 03

Page 24/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.23 Assembly of counterweight buffers and car frame.

Compulsory foot protection

Compulsory head protection

Compulsory hand protection

SEE INSTALLATION MANUAL SUPPLIED WITH SHAFT COMPONENTS 1. 2.


To assemble the counterweight buffers, anchor these to the ground, using the holes of the bed plate prepared for this. To assemble the pillar-buffers of the car frame, position these inside the frame, as close as possible to the pulley structure.

HOLES IN BED PLATE

LOCATION OF PILLAR-BUFFER

PILLAR-BUFFER

BUFFER

2.24 Assembly of counterweight protection screen.

Compulsory foot protection

Compulsory head protection

Compulsory hand protection

SEE INSTALLATION MANUAL SUPPLIED WITH SHAFT COMPONENTS

As a final component of the assembly of the mechanical part of the lift, assemble the protection screen of the counterweight frame. All the nuts and screws are in the mechanical box, including the steel plate flanges, which are used to connect the guides rails with the brackets.

Eg. Protection screen counterweight frame layout

V 0.00, Nov. 03

Page 25/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


2.25 Tools.
The tools to which we will refer are the minimum that must be carried by the installation technician to perform the assembly, and are: An electric or mechanical hoist for a minimum of 200 Kg of load. An installation template for the car and counterweight guide rails. A test button pendant. A travelling cable. A nylon or wire cord with the corresponding plumbs. Tool box or boxes A 300 gr plumb bob Two 1500 gr plumb bob Two extendable aluminium scaffolds A plumb line (tracer). A graduated metal set square. A spirit level. A hammer. A cold chisel. A 2 m flexible tape measure. An electric drill hammer. A small rotary hammer. A drill holder with adaptor for iron drill bit. An angle grinder. An electric welder. Grinding discs Two adjustable wrenches (One large and one small). A set of open wrenches from 6_7 to 27_29. A set of Allen wrenches from 2 to 12. A reversible ratchet handle. Box wrenches for controller. Combination pliers. Snipe nose pliers. Pliers for outer washers, with a curved blade Electrician scissors. A small, straight-bladed screwdriver. A medium, straight-bladed screwdriver. A large, straight-bladed screwdriver. A star screwdriver. A hexagon screwdriver. A fixed saw bow. Two steel hand saw blades. A round file. A flat file. Four quick adjustable grips. A self-gripping wrench. A voltage multimeter or tester. A scraper. Two drill bits (One large and one small). Widia concrete drill bits. Diameters 6,8,10,12,18. One long brickwork drill bit, diameter 12 x 165. Steel drill bits, diameter 2.25,3,5,7,9,11,13. A portable light with protection. An oil can. A hacksaw. A roll-up extension lead with several power sockets. A set of feeler gauges.

The above is the basic material required. The workers may use as many tools as they deem necessary, and may also use material from the site that is necessary to suitably perform their work. To avoid losing time, it may be a good idea to keep plugs, insulating tape, screws, terminals, terminal strips, rivets, etc., on hand, which may be necessary at any moment during the assembly.

Conclusion:
Up to this point, we have covered the different steps of the installation and assembly process of the SCM-07 lift. Each point may be found in more detail in the specific manuals of the various components. By way of conclusion, below is a summary of the lifts main features:

Being machine-room-less and with a fixed self-supporting structure supported on guide rails, the installation does not affect the buildings civil works, and requires a completely standard shaft. It generates the additional minimum loads, similar to those of a hydraulic lift. Its structure is extremely compact, and is built from conventional components. Due to easy access to the machine from the last floor, on the car roof, it is easy to maintain. By following this procedure and using the specific tools and the methodology proposed by MP, the installation time is similar to a conventional lift. Use of the frequency converter system with weight control enables reduced consumption, and maximum comfort, due a high stopping accuracy and the possibility of fully personalising the kinematics.

V 0.00, Nov. 03

Page 26/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


Chapter 3 START-UP
IMPORTANT:
Before start-up, check that the following is in position and correctly installed: Car and landing doors. Limit and pre-limit switches. Ropes and their attachments. Counterweight protection screen. Machine-bedframe set (check the correct tightening torque for the nuts and screws). Electric wiring in car, control cabinet and shaft (for the duplex configuration, consult the operation sequence to connect both lifts which may be found in the manuals relating to the electrical part).

3.1 Inspection and testing


a) Locking devices. Firstly, make sure that the landing doors are lined up with the car doors. There must be no friction between them or with the door frame. Check that the interlock and flap lock rollers are adjusted. Check the door interlock, making sure that once the landing door is closed the car moves. You may also try moving the door sideways when it is closed. There must be no movement. The car will only move when the interlocking elements are fitted as shown in the diagrams.

EFFECTIVE INTERLOCKING IN CLOSED POSITION AND SAFETY ELECTRIC CONTACT ESTABLISHED (*) Distance of 9 mm minimum

MAX. 2

REAR VIEW OF MECHANICAL LOCKING CAM SLIDE

V 0.00, Nov. 03

Page 27/41

(*) 9

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


b) Electric safety devices. 1. ELECTRICAL PROTECTIONS. Check that there are no loose contacts, and that the connections are tightly screwed, observing that: Differential switches: These will have the suitable trip response and be of the same intensity as the magnetocaloric switch or higher. They must be disconnected manually and with the trial test (see manual). Magneto-caloric switches: Each one of the elements that protect under normal working conditions will, as a maximum, be the double of the intensity consumed. When the current enters, it must go to the differential switch, always at the head end, from there to the magnetocaloric switch, and then to the installation. These tests shall be performed in the power and light circuit. 2. CONTROLLER.

All cable connections must be checked, both at the inputs and the outputs, and especially the power connections must be correctly secured and adjusted, checking that there is no part of the wire outside the connection terminal. Check that all of the contacts are correctly adjusted, especially those corresponding to the auxiliary contact blocks of the contactors, making sure that they are properly adjusted in their housing. If necessary, dismantle relay capsule or contact blocks to adjust or blow on them to remove possible dust impurities. The thermal relay test shall be performed with the motor at the normal working temperature, after having made several journeys, forcing one of the motor stages to skip or blocking (disconnecting) the brake so that it does not open. The time that it takes to disconnect the controller must not exceed 10 seconds, nor be lower than 8. Check that the ground connection is connected properly in the controller and that the door is connected to the earth. CAR, EXTERIOR AND MAXIMUM TRAVEL TIME TIMERS. Check that the calls from the car station have preference over the calls from the exterior control stations, with a difference of 2 seconds, at the minimum. Otherwise, adjust the car and exterior timers, making sure that the waiting times are not very long. For example: car timers 2 seconds, exterior timers 4 or 5 seconds. The maximum travel time timer must be adjusted so that, always in the most unfavourable case, this time is longer than how long it takes to cover the distance of the two consecutive floors. With this timer, the cut-off of the controller is also controlled in the event of rope slip on the pulley. 4. ELECTRIC CONTACT OF THE GOVERNOR. Check that when the governor is operated, this contact cuts off the controller. Also check the electric contact of the tension pulley. This will cut off the controller in the event of rope lengthening. 5. CAR SAFETY GEAR TRIPPING. Check that the safety gear switch has cut off the controller. 6. OPERATING THE TOP CONTROL STATION. Check that the push buttons operate in the correct direction marked in each one, and that when the testing switch is pushed into this position, the lift no longer works and the car and exterior control stations stop operating. Check that when the stop button is pressed, the lift does not work. 7. OPERATING THE END-OF-TRAVEL. Check that these cut off the controller when the lift goes beyond the travel at the extreme floors, before the car or the counterweight make contact with the buffers. 8. CAR ROOF SAFETY. Check that when the slackening of the ropes, the STOP button and any other safety device installed in the car roof are activated, the power supply of the controller is cut off, stopping the lift. 9. SAFETY SWITCHES TO CLOSE CAR DOORS. Check that the door contacts work properly, the pin and sockets fit and the connecting wires are secured tightly. 10. PIT SOCKET AND STOP BUTTON. Check that there is a socket with a ground connection and Stop button to cut off the controller. 11. EMERGENCY LIGHTING. Check that the illumination level is normal and once the current is cut off it is sufficient. The emergency lighting shall have sufficient autonomy to remain lit for one hour. 12. CHECK STOPPING ACCURACY AND SMOOTHNESS. With regard to standard EN81-70, this gives us the following parameters: the lift in stopping accuracy shall be more / less 10 mm and in levelling accuracy shall be more / less 20 mm. 13. BELL PUSHES (Exterior and car). Check that these make the lift work and that the numbers correspond with the floors. Check that the light indicators operate in order (occupied, door open, etc.).

3.

14. LOAD WEIGHING SWITCH AND INDICATOR SIGN, CHECK THESE ARE WORKING. Check that the indicator LEDs are working and that when the car is loaded with more than its nominal load, the lift does not work and in the load indicator all the LEDs light up, and the inside overload warning buzzer sounds.
15. POSITION INDICATOR. Check that this works, indicating the car position in accordance with the floor situation.

V 0.00, Nov. 03

Page 28/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


16. PHOTOELECTRIC CELL. Check that these operate when faced with an obstacle, making the doors move back in the case of the automatic landing and car doors. 17. DOOR OPENING PUSH BUTTON. Press this button and check that the doors move back, provided that the backward movement has not been cancelled and in any case, always 5 cm before closing. 18. CAR DOORS. Check that the doors fully close the entrance gap, with no spaces of more than 3.5 mm. There should be no noise when opening or closing and the lift should not start moving with an obstacle measuring more than 1.5 cm in thickness inserted in the door half. Check that the doors do not rub together and make no noise when moving. 19. GROUND CONNECTION Check that all the doors are connected by a conductor cable to the ground of the lift through a terminal.

c ) Suspension fittings and their attachments Check with a gauge that the diameter and shape of the rope is that indicated in Document no. 5 Complete list of lift components and Document no. 8 Basic rope characteristics. Check the perfect condition of the rope attachments, nuts, locknuts and safety pins of the terminals or rope sockets both in the car and in the counterweight (electric lifts). d ) Braking system Check that the brake is working properly. To do this, the car must carry 25% more than the nominal load. The test shall be performed at nominal speed and during the downwards movement, cutting off the motor and brake power supply. The brake must be able to stop the lift alone. e) Measurement of intensity or power, and measurement of speed. To check the lift speed, the lift must carry the average nominal load, checking with a tachometer that the working speed is in keeping with the project data. Check the current intensity with an ammeter clip when the lift starts and when it is working, making sure that this is correct in accordance with the motor characteristics. Make this measurement in the three phases. f) Electrical installation 1. Measurement of insulation resistance of the different circuits. By using an Ohmmeter, check that the insulation resistance values are exceeded. Nominal voltage of circuit (V) SEL 500 > 500 Testing voltage (DC) V 250 500 1000 Insulation resistance (MS) 0.25 0.5 1

The insulation resistance must be measured between each live and earth wire. To measure this, the electronic components must be disconnected. 2. Also check the continuity (connection between terminals) between the earth terminals of the machine room with the motor, controller, guide rails, governors, tension pulley and car and any component which may accidentally remain live.

V 0.00, Nov. 03

Page 29/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


3.2 Car and Counterweight:
Adherence: Check visually that there is no slip between ropes and pulley when operating normally: Mark the pulley and ropes with chalk at the same point, and check that there is no change in their relative positions, after making a full journey (up and down) with the car carrying 125% of the nominal load. Repeat the same operation with the car empty. Balancing of counterweight: To perform this test, all of the car fittings must be assembled. By loading the car with half of the peak load permitted will take the car to half of the travel, such that the counterweight is more or less at the same height. From the controller box on the last floor, and opening the machine brake, move the fly-wheel smoothly (See Rescue System Manual). Check whether the lift moves up or down; depending on this there will be an excess or lack of weight on the counterweight. It is better to leave a lack of counterweight rather than balancing it or leaving an excess (in other words, it is better that the car moves downwards). i) OVERSPEED GOVERNOR. 1. To check the tripping speed of the governor, by using a tachometer check the speed at which the governor works, making sure that this corresponds with the speed marked on the governor. For this purpose, the governor will not have the rope positioned. Work on the governor. 2. Check that when the governor contact is working it cuts off the controller. j) CAR SAFETY GEAR. Check that the safety gear has been properly assembled and adjusted. Check that the rollers or wedges do not rub with the guide rails, and therefore there must be sufficient space between the guide rails and car for the safety gear to work properly. 1. Descent test: With the car loaded with 125% of the nominal load which must be distributed evenly around the car surface area, lock the remote governor with the push button in the control cabinet. The lift will travel at testing speed. Make sure that the car stops opposite a landing door, in order to be able to unload it and free the safety gear. 2. Ascent test: Perform this in the same way, but with the car empty, and with the lift moving at nominal speed. After the test, check that there has been no deterioration that may make the normal use of the lift difficult. Replace the braking components (wedges, rollers) as necessary. A visual inspection is considered sufficient. k) BUFFERS. Energy accumulation type buffer (springs, buffers). Check this with the car carrying its nominal load in contact with the buffers, slackening the ropes and checking that the date corresponds with that given by the characteristic curve of the buffers. The distances established in Document no. 15 Installation Drawings must not be exceeded. l ) SOS DEVICE. Check that the two-way means of communication works properly. m) CAR MECHANICAL LOCKING SYSTEM. Check that the lock fits in its housing, that it moves easily in both directions and that the controller is disconnected when the frame and the car are locked. Load the car roof with 150 kg and check that the system resists without noticing any deterioration. (Caution: the car must remain empty). n) MECHANICAL RESCUE SYSTEM. Perform a simulation of the rescue operation, both in ascent and in descent. Check that after these operations the tension of the brake flexible cable is still suitable, and the mechanism that meshes the system returns to its initial position.

V 0.00, Nov. 03

Page 30/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


Chapter 4 USE OF THE SCM LIFT
4.1 Purpose of instructions.

The purpose of this chapter is to provide the instructions necessary for the correct use of the SCM lift, in accordance with standard EN 81_1 and Royal Decree 1314/97, Attachment I, 6.2 (European Directive EC/95/16). This chapter provides the information necessary for the standard use of this lift by the user, stressing a series of points which, due to their difficulty or out of necessity, make the correct use of the lift possible.

4.2 Intended use of Lift


The lift in question is manufactured to transport passengers in houses and public buildings, sometimes along with loads, the weights and dimensions of which must not exceed the lift capacity and the car dimensions. The transport of loads which may damage the installation or the car itself is completely prohibited. This lift may only be installed in those buildings in which there are no dwellings above the shaft used for the lift, nor passable areas underneath its travel. Inside the car there is a sign which specifies the lifts nominal load, expressed in kilograms, as well as the maximum number of persons. The weight of the load permitted by the lift must never be exceeded (for this purpose, there is a device in the lift that notifies that it is overloaded, being necessary to remove the excess load). The number of passengers indicated on the sign must neither be exceeded, since this may cause the lift to become overloaded. The basic operation consists of the transfer of the loaded or empty car from one level to another. Therefore, the user stands in front of the access to the lift where there is an electric push button control panel. The control push buttons on the landing doors may have different symbols or abbreviations. Below, some of the symbols or abbreviations used in our range of lifts are shown.

CALL

LL

Control push button: calls lift to go up or down

Control push button: calls lift to go up

Control push button: calls lift to go down

Once the lift has been called, its presence is detected when the doors are opened (automatic doors), when the car inside light is visible (manual door with vision panel) or when a light or sound indicator in the electric landing control panel indicates. Once the door/s are open, you may access the inside of the car where there a number of controls and a sign which specifies the lifts nominal load expressed in kilograms, as well as the maximum number of persons.

V 0.00, Nov. 03

Page 31/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


Among the controls, there are a series of push buttons which are listed below:

-1

Control push button to choose the floor desired (-2,1,0,1,2,3, etc ...)

Control push button for alarm (yellow).

Control push button to reopen doors.

Control push button to close doors.

Overload indicator.

There are also display panels indicating the floors, both inside and outside the car (landings).

The user may find other engravings on the control push buttons and indicators, since these may have been specified by the owners.

V 0.00, Nov. 03

Page 32/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


4.3 Types of Controllers:
Distinctions must be made regarding the operating of the lift depending on the type of controller: 4.3.1. Simple Automatic Controller At the moment when the car doors close, the passenger in the car has a preference of 3 seconds over the passengers on the landing to call the lift. Operating the controller in ascent: once the desired level has been pressed, the car will go directly to the chosen level. If there are several passengers, the passenger on the lowest floor must press the button first. Once the desired level has been reached and the passengers have left, the doors close, the level of the next floor is pressed, and so on. Operating the controller in descent: the passengers on the landings call the car by pressing the call push button, provided that the engaged sign is not lit, otherwise the call is not registered, nor will be attended. Once the car is on the landing, which may be indicated by the door vision panel or by the car presence light indicators, the landing and car doors may be opened, and during the seconds of preference over any other passenger on the landing, the car may be called with no interference, as described above. 4.3.2 Collective Simple Controller in Descent The lifts equipped with this controller have a memory which records calls to go up and down made by the passengers in the car. On the other hand, only the calls to go down made by the passengers waiting on the landings are recorded in this memory, not the calls to go up. Operating the controller in ascent: the controls in the car also have a preference of 3 seconds over those on the landings, from the moment when the lift is in the working position (closed doors). These also have preference after the entry of each passenger in the car, in lifts with automatic doors, with a photoelectric cell in the door threshold. As the passengers enter the car, they press the push buttons corresponding to the levels that interest them. Once the last passenger has entered the lift, the car automatically starts, stopping on the floors requested. It starts again once the last passenger for that floor has left and the doors have closed. During the ascent, the lift does not answer any floor request, except for the highest floor, provided that this is above the highest floor pressed by the passengers in the car to go up. Once on this floor, the passenger/s leave, and as always, once the doors have closed, they have 3 seconds preference over all the floors called to decide the direction of movement. If a button is pressed for the lift to go higher, the lift will go up, even if it is called from a lower floor. Operating the controller in descent: the passengers will call the descent, and the lift will go down, stopping automatically on all the floors called. 4.3.3 Collective Simple Controller in Ascent and Descent With the simple controller in ascent and descent, the car not only stops and collects passengers on landings during the descent, as the last controller does, but also during the ascent. Operating the controller in ascent: as the passengers enter the car, they push the press buttons corresponding to the levels desired, and the calls are recorded in the memory. Once the last person has entered and the doors close, the car is set in motion, stopping successively on the levels requested by the passengers in the car, as well as on the levels on which the passengers on the landings have pressed the call button to go up. The lift will not respond to the calls to go down, even if these are recorded in the memory. However, it does answer the call to go down from the highest floor above the last floor that has been called to go up. Operating the controller in descent: the car collects all the passengers on all the levels that have called the lift to go down. As the passengers enter, they press the push button for the level they desire to record it in the memory. and always in descent, the car will stop on all the levels in the order pressed by the passengers in the car and on the landings until it reaches the ground floor. 4.3.4 Duplex Controller The Duplex controller is a single controller for two lifts. In this controller, there is one single landing station on each floor and only one lift may be called. It will always answer the nearest lift. The operating of the car controls is exactly the same as that of the lifts with a simple automatic controller. The passengers will order their calls by firstly pressing the button for the lowest floor. Once this has been reached and the passengers have left, the button for the next floor is pressed, and so on the passengers press the buttons for the floors desired, in the order from the lowest to the highest. The passengers on the landings press the call push button, only when the red engaged sign goes out, and the lift car that is free will arrive. If the two are free, the nearest lift car will arrive. If there is only one lift free, after the call push button is pressed, this will light up to indicate that the call has been recorded, and the red engaged sign will light up. If the two lift cars are free, the white call push button will light up, but not the engaged sign, since there is still one lift free.

V 0.00, Nov. 03

Page 33/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


4.3.5 Collective Duplex Controller in Descent This controller is a combination of the duplex controller and the collective simple controller in descent. The layout and operating is the same as the collective controller in descent as far as the controls and signals are concerned, as well as the response to the calls for the passengers in the cars. The difference lies in that it only has one single control on each floor for the two lifts. Operating the controller in ascent: as the passengers enter the car, they press the push buttons corresponding to the destination level, and the calls are recorded in the controller memory. Once the last passenger has entered and the doors have closed, the car is automatically set in motion, stopping successively on the levels recorded and restarting when the passengers have left and the doors close. During the ascent, the lift does not answer any call to go down from a passenger on the landing, except for the highest floor, provided that this is above the highest floor pressed by the passengers in the car to go up. Once on this floor, the passenger/s leave, and as always, they have 3 seconds to press the push button and decide the direction of movement. If they press a push button to go up, the car will go up, even if it has been called to go down. Operating the controller in descent: if the passengers call the lift to go down, it will descend, stopping automatically on all the floors that have been called and in the order called by the passengers that have entered the car, provided that these are for lower floors, until the load is completed. From then onwards, the calls from lower floors will not be answered. 4.3.6. Selective Duplex controller in ascent and descent This controller is a combination of the duplex controller and the collective controller in ascent and descent. Operating the controller in ascent: as the passengers enter the car, they press the push buttons corresponding to the levels desired. Once the doors have closed, the car automatically starts, stopping on all the floors called by the passengers in the car, and in addition on the floors on which the passengers on the landing have pressed the call push button to go up. The lift will not stop on the floors on which the passengers on the landings have pressed the call push button to go down, although it records them in the memory to answer these calls during its descent. However, it will answer the call to go down from the highest floor above the last floor that has been called to go up. Operating the controller in descent: once all the calls to go up have been answered, the car goes up to the highest floor of those recorded by the passengers of the floors to go down, and after the passengers have entered the car and registered their calls, the lift begins its descent, stopping on all the floors that have been requested to go down. The lift does not answer the calls to go up, except those of the lowest floor of those that have been called, provided that this is below the last floor recorded to go down. In any case, the calls and ascents between the two lifts are distributed in accordance with a programmed standard, according to the use of the building. Having described the operating of the controller, we must now recall a number of points to bear in mind for the use of the lift: At the end of the travel (ascent or descent), the lift will stop at the requested level (to find out the stopping level, consult the number displayed or listen to the level announcer). Wait until the doors have opened and then leave the car. When the outer door is manual, the user must push this open. The lifts have a controller device for an excess of load. This device is activated when the passenger load exceeds 110 percent of the authorised load. The passengers will notice a light indicator which indicates an overload and hear a warning sound. The lift will not start until the necessary passengers have left the car to avoid going over the peak load. The passengers must enter and leave the lift as lightly and in the most orderly fashion possible, avoiding getting stuck in the door threshold. If the lift has a reopening system (photoelectric cell, etc.) make sure that you do not block its path, since this will prevent the car doors from closing. Take care when entering or leaving as you may catch clothing or objects on the doors. Try to keep away from the doors. If an unexpected situation should occur (lift stopping), try to keep calm. If the lift stops suddenly, press a level and if the lift does not respond, press the alarm push button. If this does not exist, press the outer communication control and wait for an answer. If it is necessary to perform a rescue operation, wait for the relevant instructions and explanations.

V 0.00, Nov. 03

Page 34/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


4.4 Information on the Standard Use of the Elevator:

4.4.1 Keeping documentation The lift user must be familiar with the instructions for use of a lift. These instructions must be kept so that they may be consulted at any time. In the machine room or inside the enclosure, it is advised to keep the detailed instructions to be followed if the lift stops at the wrong time, and especially the instructions on the manual rescue operation or the electrical rescue operation, and those referring to the landing door unlocking key. 4.4.2 Events that require the Intervention of Trained Staff To perform a rescue operation of passengers, as well as to use the door emergency key, it is always necessary to request the presence of trained staff. The abovementioned operations may only be performed by staff who are properly trained to do so. 4.4.3 Safe loading and unloading Special care must be taken when the car is loaded and unloaded, avoiding getting clothes, bags, packets, etc, caught on the doors. The loading and unloading procedure must be carried out in an orderly fashion, avoiding getting stuck in the door threshold. If the lift has a reopening system (photoelectric cell, etc.) make sure that you do not block its path, since this will prevent the doors from closing. The dimensions and weight of the load must not exceed the capacity permitted by the lift. The number of passengers must not exceed that indicated on the sign inside the car. 4.4.4 Openings free of obstacles on floors Avoid possible interference with the door opening due to any dangerous steps or objects (flower pots, bins, etc.) which may block safe access to the car. 4.4.5 Open Shafts Special caution should be taken when the lift is installed in an open or partially open shaft, avoiding objects falling into the shaft, as well any the insertion of any element that may damage the mobile part of the lift and interfere with the safe functioning of the lift. 4.4.6 Control cabinet / Last Floor In the access to the control cabinet, there is always a sign or poster with the following notice at least Lift control cabinet_Danger_Access prohibited to all unauthorised staff. This notice restricts access to the control cabinet, and only authorised staff may enter (maintenance, inspection and passenger rescue) with a key. During inspections, maintenance, rescue, start-up, etc., it must be checked that both the machine, the bedframe and the car roof are properly lit. 4.4.7 Use of the Emergency Key As we described in the point events that require the intervention of trained staff, the use of the emergency key is restricted to trained staff. How to use the emergency key is described in the rescue operation manual. 4.4.8 Maintenance The owner of the lift, being responsible for its use and that it is maintained under safety conditions, must hire the maintenance services from a qualified company. This company must have an incidents book for the lift, in which they note the intervention reports when important anomalies occur or components are changed in the lift, as well as interventions due to accidents. The incidents book must be made available to the owner if the latter should request so. The owner must request, in due time, the compulsory inspections and provide the maintenance company with access to perform the inspections and tests. If the installation is out of use for a long period of time, the owner must request a general inspection of the lift from the maintenance company. When any user detects an anomaly in the functioning of the lift, the owner must notify this immediately to the maintenance company and place an Out of Use on all of the lift doors. When the landings of the lift doors are cleaned, special care must be taken not to spill products (liquids or solids) inside the lift shaft.

V 0.00, Nov. 03

Page 35/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


Chapter 5 MAINTENANCE
CAUTION
ACCESS TO THE MACHINE ROOM (MACHINE, BEDFRAME, GOVERNOR, etc ... ), IS GAINED FROM THE DOOR ON THE LAST FLOOR, WHERE THE CONTROLLER BOX IS LOCATED. BEFORE ACCESSING THE CAR ROOF, STOP THIS AT A SUITABLE DISTANCE IN ORDER TO BE ABLE TO CROSS THE DOOR OPERATOR WITH EASE. DO NOT LEAVE THE OPEN CABINET UNSUPERVISED UNDER ANY CIRCUMSTANCES. THE CAR ROOF IS DESIGNED TO BEAR THE LOAD CAUSED BY THE PRESENCE OF TWO PERSONS DURING THE MAINTENANCE OPERATIONS.

5.1

Description of the electrical panel components:


Swinging supply connection Input supply network

Level indicator Alarm indicator (in multiplex installations) Electrical protections Emergency electric control unit box(optional) Reserved space for rescue system Upper-lower connections panel Control relay. Fuses. General interruptor. Temperature probe. MicroBASIC board Thermoprobe board and brake bridge rectifier board

Upper panel Fixtures for installing rescue Lighting box and power socket Intercom set (optional) Upper part

Transformer AMB1 o AMB2 board (according to installation) Lower panel Lower door Shaft and car input installation Shaft and car installing connection

Inverter capacitors

Braking resistor cable output Braking resistor swinging

Speed governor remote operation

Frecuency inverter Output filter Briefcase Contactors

Machine room connections Level indicator battery

Input supply machine

V 0.00, Nov. 03

Page 36/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


5.2 Lift Shaft:
Inspection and tests to be performed during the maintenance inspections of the lift shaft. During these tests and inspections in the shaft, in order to contact with the exterior, the worker must always carry a telephone which may be connected in any of the telephone connection boxes. In order to access the pit, use a ladder which is hanging on one of the pit walls. 1. Check that there are no water leaks in the pit and that it does not contain combustible materials or materials that may affect the functioning of the lift. Check that the pit is clean, dry and free of refuse. 2. The lift premises and pit must have sufficient artificial lighting, in order to perform the inspections properly: Check that the system is working. 3. Check that the car top control station (car roof) is working correctly and that the lift does not respond to the calls from the floors nor to those pressed inside the car whilst the inspection control device is connected. 4. IMPORTANT: The ladder to access the pit must be kept on its fastening bracket, on one of the side walls of the pit, after the maintenance work.

5.3 Guide rails


Inspection and tests to be performed during the maintenance inspections of the guide rails. 1. Check the state of the car guide rails and counterweight, and their fastenings. Check for possible changes in the distance between guides. 2. Should automatic lubricators be required in the car and counterweight, the level of oil must be controlled and refilled if necessary. Chen the guide rails have no automatic lubricator, it is recommended that the guide rails are lubricated every 2 to 3 months, depending on the level of use. Always use the relevant lubricant for each material. An excess of lubrication may be as harmful as too little

5.4 Access Doors


Inspection and tests to be performed during the maintenance inspections of the lift access doors. 1. Check that the series are working correctly in all doors. The lift will not operate if one of the contacts of the series fails. To check this in the case of automatic doors, prompt the failure by activating the lock. 2. Check that the mechanical locking of the door works properly. To do this, try moving the door sideways. There must be no movement.

V 0.00, Nov. 03

Page 37/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


3. In the case of automatic doors, both in start-up and periodic inspections, make sure there is no interference or overlap between the grips of the mechanical locking, as well the possibility of disconnection due to the movement of the door panel. Therefore, make sure that the distance of 9 millimetres is respected, as shown in the figure.

Effective interlocking in closed position and safety electric contact established

MAX. 2

Rear view of mechanical locking cam slide (*) Distance of 9 mm, minimum. For this distance, only measure the straight surface from the end of the curve. 4. During the periodic inspections, the following must be controlled: locking, sensitivity to reopening of the door when a passenger is hit or about to be so, failure to start with the door open, wear and tear of the door guide shoes, contacts, carriage wheels, etc. Clean, adjust or change as necessary, (consult landing doors assembly manual).

5.5

Ropes:

Inspections and tests to be performed during the start-up inspections and maintenance inspections of the driving ropes and their fastenings. 1. Both in start-up and periodic inspections, check the state of the entire length of the cables. To do this, cut any broken wires. A broken cord or wires in one metre long of rope, makes it necessary to change all of the ropes. To detect broken wires, pass a cotton cloth along the length of the rope. Occasionally, broken wires occur due to wear and tear (friction); these can be checked visually. 2. Check the state of the rope fastenings to the counterweight and the car, especially the nuts of the rope attachments. 3. Check the lubrication of the ropes, bearing in mind that the ropes should be not covered with grease that makes it impossible to check their state. 5.5.1 Procedure to Replace the Ropes a) Lock the car in the bottom locking holder, and at the same time, hang the counterweight in the top part of the shaft, without exceeding the maximum load permitted by the hooks hanging in the overhead. b) Place additional safety slings on both frames.

V 0.00, Nov. 03

Page 38/41

(*) 9

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


c) Change ropes by working from the pit for the car frame and with the assembly scaffolds located on the last landing for the counterweight and machine frame.

5.6 Machine and Bedframe:


Inspection and tests to be performed during the start-up and maintenance inspections of the lift, bedframe and mechanical brake, (see Manual for Use and Maintenance of Sassi Leo Machine). 1. Check the correct tightening torque for the screws and fastenings of the machine-bedframe assembly. 2. Check the state of the rope anti-slip system and the pulley protection assembly. 3. During the periodic inspections, it must be checked that the machine is clean, with particular attention paid to the ventilator and electric components.

1.

The disc brake of the machine does not require any type of adjustment, since it is delivered from the factory already fine-tuned and calibrated. If it is necessary to adjust it, consult the specific instructions of this device.

5.6.1 Procedure to Replace the Machine a) Lock the car in the top locking holder, and at the same time, hang the counterweight in the bottom part of the shaft, without exceeding the maximum load permitted by the hooks hanging in the overhead. b) Place additional safety slings on both frames. c) Dismantle the rope anti-slip system and the traction pulley protection. d) Remove the ropes of the driving pulley one by one, and leave them supported over the safety slings. e) Disconnect the electrical installation of the machine and dismantle the rescue system. f) Change the machine, ensuring its position hanging from the lifting system before dismantling the four fixing screws, without exceeding the maximum load permitted by the hooks hanging in the overhead. g) Remove the machine from the shaft without supporting it on the car roof. h) To assemble the new machine follow the process in reverse.

V 0.00, Nov. 03

Page 39/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


5.6.2 Procedure to Replace the Pulley a) Lock the car in the top locking holder, and at the same time, hang the counterweight in the bottom part of the shaft, without exceeding the maximum load permitted by the hooks hanging in the overhead. b) Place additional safety slings on both frames. c) Dismantle the rope anti-slip system and the traction pulley protection. d) Mark each one of the ropes with its current position in the traction pulley to avoid them getting crossed or tangled up when they are repositioned. e) Remove the ropes of the traction pulley one by one, and leave them supported over the safety sling. f) Change the pulley. g) Reintroduce the ropes in the pulley.

5.7 Overspeed Governor:


Inspection and tests to be performed during the start-up and maintenance inspections of the overspeed governor (consult overspeed governor installation and assembly manual). 1. Check that the governor works reliably and safely. The bearings must be checked and lubricated each year. 2. Check that the rope tension is maintained in the tension pulley. Make sure that the safety contact is working properly when slackening of the ropes occurs. 3. Check whether the governor rope has lengthened beyond the distance allowed, which may activate the safety contact in the tension pulley. If lengthening has occurred, trim the cable. 4. Check that the rope wires of the governor are not damaged. Should this occur, replace the rope. One method of finding out the state of the ropes is to check whether there are any broken cords or wires along a length of one metre. To detect these, pass a cotton cloth along the length of the cable. Occasionally, broken wires occur due to wear and tear (friction), these can be seen visually. 5. Frequently and safely check the functioning of the overspeed contact (governor contact). 6. Check the rope attachments and pulley grooves, cleaning foreign particles in order to ensure the proper functioning of the governor.

5.8

Buffers:

Inspection and tests to be performed during the maintenance inspections of the buffers. 1. Check the buffers and their state (check maintenance, installation and use of buffers manual).

5.9 Alarm Device and Emergency Stopping:


Inspection and tests to be performed during the maintenance inspections of the alarm device. 1. Check that this works and that it is audible from outside the shaft by the persons responsible for providing help. 2. Check that all the stopping switches (pits, car roof and car stop control stations) work correctly. 3. Check that all the systems of the lift for alarms, emergencies and rescue procedures work properly (emergency lighting, telephones, etc).

5.10 Rescue System:


5.10.1 Inspection and Tests to be performed during the Maintenance Inspections of the Rescue System. 1. Check the functioning and state of the meshing system with the machine shaft and remote brake opening from the rescue controller. Check the tension of the brake flexible cables (consult the rescue system manual). 5.10.2 Inspection and Tests of the Car and Access thereto 1. Check the general state of maintenance of the car and its frame. 2. Check that the car lighting is permanently on. 3. Check that the stopping switch in the car roof works correctly. 4. The distance between the car door and access door must not be more than 20 millimetres, except in the case of simultaneous automatic doors, which may reach up to 30 millimetres. 5. Check that there are toe guards in the car and in the access doors. 6. Check that the lift does not start with the car door open and that, once in motion, it stops when the door opens, except in the case of automatic doors with floor levelling, in which case the levelling may be checked during the opening of the doors. 7. Check that the car door operates freely, as well as the sensitivity of this to an obstacle. 8. Check that car doors make contact. 9. Check that the panels slide correctly, as well as the state of the guide shoes. If there is wear and tear, change them. 10. Check that there is a load plate inside the car. 11. Check that the call push buttons on the landing and the push buttons in the car (for example, to select a level or close the doors) work properly. 12. Check that the two-way communication channel is working (car with exterior).

5.11 Counterweight
5.11.1 Inspection and Tests of Counterweight

1. Check the state of maintenance of the frame that supports the weights, especially the nuts, locknuts, guide shoe brackets, etc. 2. Check rope clamps, nuts, locknuts and safety pins of the terminals or rope sockets.

V 0.00, Nov. 03

Page 40/41

MACSCM-07

PRODUCT TECHNICAL MANUAL SCM-07 Complete Lift


5.12 Guide shoes
1. The guide shoes must be changed one by one, but not simultaneously. 2. When the old guide shoes are taken off, make sure that the frame does not move too much, in order to place the new ones on easily.

5.13 Safety gear


5.13.1 Inspection and Tests of Safety gear

1. Check the state of the wedging box, and the absence of foreign bodies inside it. 2. Check that there is no corrosion in the safety gear or wedging box (consult wedging box installation and assembly manual).

5.14 Batteries
1. Check the state of the large and small emergency batteries of the installation, and that these have sufficient electric charge.

5.15 Load weighing switches


5.15.1 Inspection and Tests of Load Weighing Switches (consult the load weighing switch installation manual).

5.16 Electrical Safety Circuits (consult the preassembled electrical installation manual).
5.16.1 Inspection and Tests of the electrical safety circuits 1. Check that the ground lines that connect the door frames, flap locks, motor casing or motors and control unit are in a good condition, connected to the earth or to the metal guide rails. 2. Check that grounding of the conductors of the safety circuits cause the lift to stop. 3. Check the correct functioning of all the safety devices and these cause the lift to come to a complete stop. 4. Check the proper functioning of the electric rescue equipment, if the installation is equipped with this. 5. Check currents and voltages as necessary.

5.17 Signs and Controllers (consult the preassembled electrical installation manual).
5.17.1 Inspection and tests of signs or controllers 1. In the case of closed shafts with access doors without vision panels, and not automatic, there must be a light indicator in front of the door that notifies of the presence of the car: Check that this works on each floor. 2. Check that the delay works, giving priority to controls from the car over exterior calls. 3. The final safety stop at the ends of the travel must be caused by the final safety switches which are different to those that normally stop the lift at the top and ground floors. Check they work correctly and that the car clearances in the guide rails do not hinder their functioning. Check the correct levelling on all floors, both with the car empty and at full load. 4. Check the state of the relays and contactors, as well as their behaviour if a phase produces an error or if they invert. 5. Check the last recordings of errors if the controller is equipped with the error storage device.

5.18 Controller Box


5.18.1 Inspection and tests to be performed on the controller box 1. There is electric lighting in the controller box and a safety switch which keeps the lift at a stop when necessary for inspection. Check that this works. 2. Check the general switch, contactors, relays, fuses and the level of artificial lighting. 3. Inspection of feasibility and safety in the access to the controller box for the safety of the maintenance staff. 4. Check the state of the controller box flap locks, and that these make it possible to close it without using a key. Lubricate the flap locks regularly. 5. After each inspection, clear the access to the controller box.

V 0.00, Nov. 03

Page 41/41

MACSCM-07

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

DYNATECH PROGRESSIVE SAFETY GEAR PR-2500-UD (V.50)

INSTRUCTIONS FOR USE AND MAINTENANCE

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

-1-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

-2-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

-3-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

-4-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

-5-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

-6-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

INSTRUCTIONS FOR USE AND MAINTENANCE


_______________________________________________________________ 1. GENERAL INDICATIONS. 2. SAFETY GEAR INSTALLATION. 2.1. TO THE SLING MAKER. 2.2. TO THE INSTALLER. 3. USE AND MAINTENANCE. 3.1 GUIDE RAILS. GREATER. 3.1.2 GUIDE RAILS WITH A GRIPPING WIDTH OF 20mm. 3.2 SPEED GOVERNOR. 3.3 RANGE OF USE. 3.3.1 GUIDE RAILS WITH A GRIPPING WIDTH OF 25mm OR GREATER. 3.2.2 GUIDE RAILS WITH A GRIPPING WIDTH OF 20mm. 3.4 FRICTION PARTS REPLACEMENT. 3.5 MAINTENANCE. 3.5.1 CLEANING. 3.5.2 CORROSION. 4. GENERAL DRAWING. _______________________________________________________________ 3.1.1 GUIDE RAILS WITH A GRIPPING WIDTH OF 25mm OR

-7-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

1.-GENERAL INDICATIONS.
Each supplied set of safety gears has been regulated at the factory according to the required use characteristics: Total weight (P+Q) and the guide rail thickness. These characteristics, the EC type examination number and the serial number are shown on the protection plates attached to the safety gear boxes. It is absolutely forbidden: a) To combine and install safety gear boxes with different serial numbers. b) To use a set of safety gears for installations with different characteristics to the ones shown on the protection plates of their safety gear sets. c) To intervene on any safety gear component. DYNATECH DYNAMICS & TECHNOLOGY, S.L. will not be responsible of any damages caused by the unobservance of any point of these general indications.

2.-SAFETY GEAR INSTALLATION.


The Standard requires that the safety gear installation must be done including a security contact of type AC - 15 or DC - 13 according to EN 60947 - 5 - 1.

2.1- TO THE SLING MAKER: The fixing holes for the safety gear must be made in the sling sides according to the dimensions and positions shown in the enclosed safety gear drawings, making sure the guide rail axis center to the sling beams.

-8-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

Once the safety gear is well placed and its roller trains are attached to the driving bars, it should be checked that both trains act synchronized in accordance to the driving bar commands. The sling maker is responsible for the proper location of the safety gear on the sling as well as the adjustment checking and synchronized working of the driving bar. The pin of the train, in its rest position, must be at the central point of the protection plates.

Rest position

-9-

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

Downwards engagement

Upwards engagement

- 10 -

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

As a suggestion for the safety gear fixing to the sling, the tightening torque of 8.8 M12 screws is 79.09 Nm and 111 Nm for those of 10.9. Remark: The rollers for the downwards engagement marked with a D letter, must remain always at the lower part of the safety gear. The letters which rollers are distinguished with can be appreciated at first view trough the long hole of the protection plates.

2.2- TO THE INSTALLER: During the installation at the well, first of all, the guide rails must be introduced in the grooves of the safety gear housings. Then the position of the guide rail in the housing is adjusted as follows: the side of the guide rail, 1.5 mm from the brake block, the guide head, 3mm from the bottom of the groove (see drawings). For these adjustments the sliders will be handled without modifying the position of the safety gear in the sling because the sling maker - 11 -

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

must have properly fixed the safety gear in its final position. For the correct safety gear acting, the distances mentioned here above must be strictly respected by the installer.

To make easy the adjustment at work of the distances between the faces of the guide rails and the parts of the safety gears which are opposite the guide rail, it will be possible to use plates which will allow the emplacement of the guide rail in its correct position in the grooves of the safety gear. The plates must be removed once the adjustment operation has finished.

Remark: The installer must be sure that the sling maker has situated the rollers for the downwards engagement, marked with a D letter, at the lower part of the safety gear.

- 12 -

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

3.-USE AND MAINTENANCE.


The non-fulfilment of the following prescriptions may produce deceleration values and breaking distances which could not be in accordance with the Standard.

3.1-GUIDE RAILS:
3.1.1.-GUIDE RAILS WITH A GRIPPING WIDTH OF 25mm OR GREATER.

a) The guide rails used can be either the cold-drawn or the planed type. The admissible tolerances for the guide rails thickness are between 0 and +0.10 mm. b) The progressive safety gear PR-2500-UD can be used with this type of guide rails until a nominal speed of 2m/s and the governor response maximum speed is 2.5 m/s. c) If after the safety gear performance you find scratched guide zones placed within a

distance of less than 1 meter between them, it is recommended to substitute the affected guide parts. d) The guide rails must be lubricated with ISO VG 150 oil lubricant.

3.1.2.-GUIDE RAILS WITH A GRIPPING WIDTH OF 20mm.(for example T 65/A) a) The guide rails used can be either the cold-drawn or the planed type. The admissible tolerances for the guide rails thickness are between 0 and +0.10 mm. b) The progressive safety gear PR-2500-UD can be used with this type of guide rails until a nominal speed of 1m/s and the governor response maximum speed is 1.5 m/s.

- 13 -

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

c)

If after the safety gear performance you find scratched guide zones placed within a

distance of less than 1 meter between them, it is recommended to substitute the affected guide parts. d) The guide rails must be lubricated with ISO VG 150 oil lubricant.

3.2-SPEED GOVERNOR:
The speed governor rope tension has to be big enough to warrant, during the governor performance, a traction of 300 Nm at least in the connection point of the safety gear driving bar.

3.3-RANGE OF USE:
3.1.1.-GUIDE RAILS WITH A GRIPPING WIDTH OF 25mm OR GREATER. Here below the standard P+Q board is shown. The nominal values are those of the central line.

-7'5% 567 P+Q 613 +7'5% 659

658 711 764

764 826 888

859 929 999

963

1060 1178 1317 1454 1627 1808

1041 1146 1274 1424 1572 1759 1955 1119 1232 1370 1531 1690 1891 2102

- 14 -

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

3.1.2.-GUIDE RAILS WITH A GRIPPING WIDTH OF 20mm.(for example T 65/A)

-7'5% 621 P+Q 671 +7'5% 721

3.4-FRICTION PARTS REPLACEMENT:


The friction parts, brake shoes and rollers, can support three free fall upwards performances and three downwards performances, as it is exposed in the Standard EC typeexamination criteria. Anyway, after having intervene in a real situation it is recommended to replace the friction parts. In that case, contact Dynatech or its nearest distributor, in order to know the procedure to be followed.

In order to obtain a better control, the maintenance person may have a register of the safety gear performances. The safety gear serial number should be written in its register as well as each and every acting. It is not necessary the braking parts replacement, caused by normal inspection tests, unless the braking distance surpass the double of the one obtained at the very first test of the installation.

- 15 -

INSTRUCTIONS: PR-2500-UD (V.50) Date: 12-09-2002 Check: 01

3.5-MAINTENANCE:
3.5.1.-CLEANING. It is very important to make sure that there is not any alien element inside the safety gear housing in order to guarantee the proper work of the moving parts.

3.5.2.-CORROSION. Dynatech safety gears have anticorrosive protection in all cases. However, a periodical checking must be done to make sure that all the moving elements of the safety gear are still in perfect work conditions. A wedging test is not necessary, but a simple check of its free movements and a visual checking of the surfaces general condition. These verifications must be done more often when the installation is placed inside a specially corrosive atmosphere.

4.-GENERAL DRAWING

- 16 -

Date: 12-09-2002

258 45 30,6 178

Check: 01

INSTRUCTIONS: PR-2500-UD (V.50)

1.5 d

72,75 f e
d(mm) f(mm) e(mm) h(mm) 21.529 22.029 22.529 23.029 23.529 24.029 24.529 25.029 25.529 77.929 78.429 78.929 79.429 79.929 80.429 80.929 81.429 81.929 32.75 32.75 32.75 34.75 34.75 34.75 34.75 34.75 34.75 27.50 27.00 26.50 28.00 27.50 27.00 26.50 26.00 25.50

120
D Y N A T E C H
D Y N A M I C S & T E C H N O L O G Y

3.5

9,5

Guide rail thickness

8 9 10 11 12 13 14 15 16

PR-2500-UD (V.50)

- 17 -

MicroBASIC
Control Board

I
TECHNICAL DOSSIER
VERSION 2.0 May 1999 PRE-ASSEMBLED ELECTRICAL INSTALLATION IEPMBAS SOFTWARE VERSIONS MB134 OR HIGHER

DECLARACI N DE CONFORMIDAD DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE BEREINSTIMMUNGSERKLAERUNG


Directiva del Consejo, relativa a la compatibilidad electromagntica, con la que se declara conformidad : Council Directive, concerning the electromagnetic compatibility, to which conformity is declared : Directive du Conseil, concernant la compatibilit lectro-magntique, par laquelle est dclare la conformit : Richtlinie, in Bezug auf die elektromagnetische Kompatibilitt, deren bereinstimmung besttigt wird :

89 / 336 / CEE
Aplicacin de las Normas : DRAFT pr EN 12015 (95) (94) EN 801-2 (91) Application of the Standards : DRAFT pr EN 12016 (95) IEC 801-3 (84 + Rev.93) Application des Normes : EN 55011 (91) IEC 801-4 (88) Anwendung der Normen : EN 50082-1 EN 50081-1 (94)

Fabricante / Manufacturer name / Fabricant / Hersteller s Mecanismos y Accesorios, S.A. Direccin / Manufacturer address / Adresse s Poligono NAVISA c / E - 41006 - SEVILLA - ESPAA Tipo de equipo / Type of equipment / Type dquipement / Gertetyp Maniobra de control para ascensores elctricos y oleodinmicos Control driving for electric and oil-dynamic lifts Manoeuvre de contrle pour ascenseurs lectriques et hydrauliques Steuerungselektronik fr Seil- und lhydraulikaufzge Modelo / Model no. / Modle / Modell MicroBASIC
El abajo firmante, declara que el equipo antes especificado cumple con la Directiva y las Normas mencionadas I, the undersigned, hereby declare that equipment specified above conforms to the above Directive and Standard Je, soussign, dclare que lquipement dcrit ci-dessus remplit les conditions contenues dans la Directive et les Normes mentionnes Der Unterzeichnende erklrt, dass das obenerwhnte Gert der aufgefhrten Richtlinie und den angegebenen Normen entspricht und diese erfllt

Nombre / Full name / Prnom, Nom / Unterzeichnet GONZALO MADARIAGA PARIAS Cargo / Position / Responsabilit / Stellung PRESIDENTE MACPUARSA, S.A.

Lugar / Place / Lieu / Ort : Fecha / Date / Datum :

SEVILLA 26/06/96

Firma / Signature / Unterschrift :

CONTENTS
Chapter 1 PRESENTATION
GENERAL FEATURES ................................................................................................................................................................. 1 STANDARD DATA ........................................................................................................................................................................ 1 SPECIAL DATA ............................................................................................................................................................................ 2

Chapter 2 MAJOR COMPONENTS AND THEIR FUNCTION


MAJOR COMPONENTS AND CONFIGURATION ELEMENTS .................................................................................................. 3 FUNCTION OF RELAYS AND VARISTORS (VOLTAGE LIMITERS) RELAYS ........................................................................................................................................................................................ 4 VARISTORS (VOLTAGE LIMITERS) ............................................................................................................................................ 5

Chapter 3 CONFIGURATION AND ADJUSTMENT OF PARAMETERS


ELEMENTS FOR CONFIGURATION DIL Switches ............................................................................................................................................................................... 6 METHOD FOR PARAMETER ADJUSTMENT ............................................................................................................................. 6 RUN MODE ................................................................................................................................................................................ 6 PROGRAM MODE ....................................................................................................................................................................... 7 Modification of parameters (PROGRAM Mode) .................................................................................................................... 8 DESCRIPTION OF PARAMETERS Parameter Parameter Parameter Parameter Parameter Parameter Parameter Parameter [ 0 ] [ 1 ] [ 2 ] [ 3 ] [ 4 ] ..................................................................................................................... 9 [ 5 ] [ 6 ] ......................................................................................................................................................... 10 [ 7 ] [ 8 ] [ 9 ] [ 10 ] [ 11 ] ................................................................................................................ 11 [ 12 ] ................................................................................................................................................................... 12 [ 13 ] [ 14 ] [ 15 ] ...................................................................................................................................... 13 [ 16 ] [ 17 ] [ 18 ] [ 19 ] ........................................................................................................................ 14 [ 20 ] [ 21 ] [ 22 ] [ 23 ] [ 24 ] ......................................................................................................... 15 [ 28 ] ................................................................................................................................................................... 16

Chapter 4 INFORMATION OFFERED BY CONTROL


INDICATOR LIGHTS .................................................................................................................................................................. 17 POINTS ON THE DISPLAY ........................................................................................................................................................ 17 VOLTAGE VALUES ..................................................................................................................................................................... 17 DISPLAY WITH 3 DIGITS ......................................................................................................................................................... 18 INDICATION OF SPECIAL INFORMATION .............................................................................................................................. 18 STANDARD INFORMATION ..................................................................................................................................................... 19 DESCRIPTION OF BLOCKS OF INFORMATION ..................................................................................................................... 19 VIEWING OF CONDITIONS OF ELEVATOR COMPONENTS .................................................................................................. 21 TECHNIQUE OF REPRESENTATION OF ERRORS .................................................................................................................. 22

Chapter 5 FUNCIONAMIENTO DE LA MANIOBRA


BASIC FUNCTIONAL STEPS Luminous sequence ................................................................................................................................................................ 23 Return control (connection on final floor) ............................................................................................................................ 23 Criterion direction of correction ............................................................................................................................................. 23 Normal control ......................................................................................................................................................................... 24 Inspection control .................................................................................................................................................................... 25 Emergency control (only for hydraulic elevators) ................................................................................................................ 26

May 1999 Version 2.0 Control Board MicroBASIC

CONTENTS
DESCRIPTION OF SPECIAL FUNCTIONS Repeated door close or interlock error ................................................................................................................................. 27 Interruption of photoelectric barrier in car or opening of automatic hoistway door ..................................................... 27 Repeated door close or interlock error ................................................................................................................................. 27 Fireman control ........................................................................................................................................................................ 27 Fireman key switch in hoistway .......................................................................................................................................... 27 s Fireman key switch in car .................................................................................................................................................... 28 s Mixed selective control ........................................................................................................................................................... 28 Asymmetric elevators ............................................................................................................................................................. 28 Operation emergency power aggregate .............................................................................................................................. 29 Deletion of car calls ................................................................................................................................................................. 29 Re-levelling ................................................................................................................................................................................ 29 Levelling with open doors ....................................................................................................................................................... 31 Stopping on lowest floor (hydraulic elevators) .................................................................................................................... 31 Grave errors .............................................................................................................................................................................. 31 Stopping for opening and subsequent closing on final floor (hydraulic elevators, error F03) ..................................... 31

MicroBASIC Control Board Version 2.0 May 1999

Chapter 1 GENERAL FEATURES

PRESENTATION

Monitor control for traction elevators and hydraulic elevators with a high cost/performance relation. Used in a very high number of installations (> 90%). Real time presentation of the condition of all components of the installation and memorising of functional errors.

STANDARD DATA
Traction elevator and hydraulic elevator with only one PCB MicroBASICcontrol board. Configuration SIMPLEX : Universal ........................................................................................ 16 floors. Collective selective control during descent .............................. 10 floors. Collective selective control during ascent and descent .......... 6 floors. Configuration DUPLEX : Universal ........................................................................................ 16 floors. Collective selective control during descent .............................. 10 floors. Collective selective control during ascent and descent .......... 10 floors. With extension board AMB1: up to 16 floors, collective control, up and down direction, Simplex. With extension board AMB2: up to 16 floors, collective control, up and down direction, Quadruplex, remote control possible. Independent controllers will be supplied for Duplex and Quadruplex. Speed regulation by adding 3VFMAC1 (freqency converter).Optimised quality/cost solution for speeregulation installations up to 1,6 m/sec. The product may be used for transformation of older installations with 1 speed into installations with high operating quality. Voltage of safety circuit ............................................................... 110V ac. Control voltage .............................................................................. 24V dc. Call registration at 24V dc (standard) with protection against overload and short circuits. Outlets for position indicator (display). Standard : binary 24V dc. Optional: decimal for each voltage, dc or ac. Outlet for door drive motor. Standard: single-phase 220V ac or 220V ac + interlock magnet signal. Optional: ac current motor with 110V, 220V or 380V alternate current; dc current motor with 12V, 24V and 48V direct current. Signal voltage hoistway: direction indicator ascent and descent, occupied, free, door open. Signal voltage in car:direction indicator ascent and descent 24V dc. Standard: 24V dc. For other voltage values please procure information first. Re-levelling and levelling with open doors (traction elevators and hydraulic elevators), with incorporated levelling device 538. Real time detection of errors in the installation. Analyses more than 20 types of errors. Memorisation of the last 32 errors. Display on PCB MicroBASIC, indicating the following points in real time: Position of car. Installation component which prevents movement of the elevator. Type of call and floor served. Registered hall calls ascent and descent. Condition of elevator components. Errors memorised.

May 1999 Version 2.0 Control Board MicroBASIC

PRESENTATION
For hydraulic elevator - equipped with trigger for emergency valve, for completion of run on the next floor in down direction or any other floor (e.g.: on first floor). At minor increment of cost a complete system for the rescue of passengers may be added : Traction elevator: Rescatamac 30. Hydraulic elevator: Door opening function, 041, 042, 043. Very ample range of functions. Up to 30 configuration parameters. Fireman control with double key (car and hoistway). Connection of load weighing device (overload and full load), with car signal voltage 24V dc. Control emergency power aggregate. Asymmetric elevators (on upper or lower floors). Autocontrol of operating panels: If a call button remains blocked (active) for more than 60 secs., while the elevator is at floor-level, calls of this floor will be deleted, and the elevator continues to function normally. This floor will once again be served as soon as button is no longer blocked. Outlet for break and interlock magnet at any voltage. Optional signals with extension board MS - MPX: Indicator light arrival (levelling). Indicator light next run (direction indicator), both at any voltage, dc or ac. SPECIAL DATA Special functions may be set up in single installations, if desired. Access control functions.

MicroBASIC Control Board Version 2.0 May 1999

Chapter 2

MAJOR COMPONENTS AND THEIR FUNCTION


MAJOR COMPONENTS AND CONFIGURATION ELEMENTS
CONFIGURATION ELEMENTS
R62 Q1 R21

T1 T2
C34 C36

P4

R87 X1 C78 C79

C88

U29 C90

32
D8

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

D3 SC
R36

D2 SP

D1 IMP
R60 U9

75176B PL1
U16 C46

P3
R8 R67 U26 R7 C86 NO LEVEL DL11 D15 R9 EMERG DL7 FF1 D9 D87 R61 + R75 C85 UDN 2543 D69 R64

C87 R76

C77

R19 R24 R59 R56

R78 D96

R77 R23

F5 / FF1

D92 D10 R74

P2
k j i h g f
DZ35

SW
SW C80

DZ1

74HC165

U27

DM9368

R85

R14

TLP-521
U23

ST9040

U24

R15

RMINV RL4

74HC165
S/N U4 C45 U18 U22 C57 C81

R65 +5V DL9 X16 U28 R63

RME2 RL3

RME1 RL2 RME D95

RME

TLP-521
D75 D88 R79 U10 R81 R80

U30 D94

U19

74HC165
U17 R57

C92

74HC164

74HC14

LM2825

V8 C91 C89

R17 DL10 + +24V

e d c b a
PR2 R18 DL10

D76

D77

D78

RDIP
D64 DZ27 DZ28

UDN2981
C47 DZ26 R11 R43 C58 C76 R12 D63 D61 D60 D59 D58 D57 D56 D62 C32 C29 RET RDIP D85 C75

103
R50

FF2

U15

C44 DZ29 DZ30

C67 DZ31 DZ32 DZ33

C74

C72

R52 R45 R46 C69 C68 PR3 PR4 R53 PR5 PR6 R49 FT

FF2

R51

ULN2003

R55 R82 R83 DZ34

C55 C56

C53 C54 C73

U13 U7

R47 R48 C70

C50 C51

C49 C52 C71

C48

C59 RBCAB

C60 R71

C61 U5

C62 D40 D42 D43 D44 D45 D46 D47 D41 C30

C63

C64 R69

U6

C65

C66 D55 D53 D52 D51 D50 D49 D48 D54

R73

D81

D82

F6 / FL
FL D79 D80 D90 R10 DL8 RMT

F4 / FT
RM DL1 DL5 RMR R1 D4 D1 RB

F1 / FM J2
DL3 R3 D7 RS DL4 D68 R4 D3 RVR

FM

P1
16 15 14 13

D5

D86

UDN2987

UDN2987

UDN2987

R54

RBCAB

+24 VREG 0VCC


P5 R70

D83 D84

J4
R5

DL6 R6 D2

R72 C31

R68 R39

J3
U3 RBEXT C3

74HC165
C18 C17 C16 C5 C4

74HC165
C13 C12 C11 C7 C9 C8

74HC165
C25 C23 C19 C20 C21 C22

RET RL21

RMT2 RL7

RMT3 RL13

RMT1 RL12

RM RL10

RMR RL6

RB RL8

RS RL9

RVR RL11

12 11 10

U1 C27 C15 C10 C6

U2 C28 C14 C26 C24

9 8
RLS RLB RLDO RMP D12 RZS C119 D11 ROPC ROPA

DZ17

DZ16

DZ15

DZ14

DZ13

DZ12

DZ11

DZ10

DZ25

DZ23

DZ24

DZ22

DZ18

DZ19

DZ20

DZ21

DZ2 RL22

DZ3

RDIP
D66 D16 D31 D17 D30 D18 D29

DZ4

DZ5

DZ9 R31

DZ8

RDIP
D22 D25 D20 D27 D21 D26

DZ7

DZ6

7 6

R32

RLS RL18

RLB RL19

RLDO RL20

RMP RL14

RZS
C2

ROPC RL17
R25 R26 D92

ROPA RL16

5 4 3 2

R30

R29

RDIP
D39 D37 D38 D36 D35 D34

RL5

D14

R27 D19 D28

R28 D23 D24

RL1

RPA

D32 D33

D13

110

1 J1
C37 F3

CH1 CC1
109 111 112 113 114 115 116 117 118 119 120 +24 A B C D

CH2 CC2
213 217 218 215 294 214 105 0VCC 104 226 220 228 10 2 0VCC 00 203 106 207 105 217 +12F 208 102 9 220 T T 103 5 207 0VP 223 222 221 103 218

FOP
V5

V4 V3

C38

PCB MICROBASIC SERIGRAPHY OF COMPONENTS


JUMPERS
J1 DO NOT FIX JUMPER IF CFE (EMERGENCY FINAL CONTACT) IS USED J2 FIX JUMPER, WITH THE EXCEPTION OF TRACTION ELEVATOR 1 SPEED J3 ONLY FIX JUMPER IN CASE OF UNIVERSAL CONTROL J4 FIX JUMPER, WITH THE EXCEPTION OF HYDRAULIC ELEVATORS WITH KLEEMAN AGGREGATE

SIGNALISATION OF POINTS ON THE DISPLAYS


D3 SC D2 SP D1 IMP
PULSE: ON. PULSE (LUMINOUS) OFF. NO PULSE (NOT LUMINOUS) DOOR CIRCUIT: ON. CLOSED (LUMINOUS) OFF. OPEN (NOT LUMINOUS) INTERLOCK CIRCUIT: ON. CLOSED (LUMINOUS) OFF. OPEN (NOT LUMINOUS)

FUSES
FOP FM FT FL FF1 FF2 FUSE PROCESSOR ( 3A ) FUSE CONTROLLER ( 1A ) FUSE CURRENT SOURCE 5 V DC 1A ), MAX. ( 1A ) FUSE SIGNALS ( 1A ), MAX. ( 3A ) FUSE CURRENT SOURCE 24 V DC 3A ), MAX. ( 3A ) FUSE 20 VS ( 3A ), MAX. ( 3A )

CC1 CC2 CC3 CH1 CH2


TERMINALS CONNECTION IN CAR AND HOISTWAY

P1 P2 P3
TERMINALS CONNECTION WIRING IN CONTROLLER

P4
TRANSMISSION CABLE CIRCUIT (RS - 485) FOR DUPLEX CONNECTIONS WITH EXTENSION MB1 AND AMB2

PINS
PIN 103 PIN RME PIN 207 PIN CONNECTION HYDRAULIC ELEVATORS WITH SPECIAL AGGREGATE PIN CONNECTION TIMER FOR RME (HYDRAULIC ELEVATORS WITH INTERLOCK MAGNET) PIN CONNECTION WITH LEVELLING DEVICE 538. INDICATOR LIGHT BETWEEN FLOORS

May 1999 Version 2.0 Control Board MicroBASIC

MAJOR COMPONENTS AND THEIR FUNCTION


FUNCTION OF RELAYS AND VARISTORS (VOLTAGE LIMITERS) Relays RB : RCAB : RBEXT : Descent. Active when car initiates or realises a descent, 24V dc. With red indicator light. Car call. Deletes car calls during inspection (terminal 109), 24V dc. Hall call. Deletes hall calls (terminal 110), 24V dc, if jumper J3 is fixed (configuration Universal) and relay is connected during service of elevator. Start (hydraulic elevators). Ventilation (traction elevators), 24 V dc. Control relay RZS. Connected directly at microprocessor, permits connection of RZS, each time that the safety contact CPS (terminals 00, 103) is closed, 24V dc. Indicator light descent, 24V dc. Indicator light free (not active) and occupied (active), 24V dc. Indicator light ascent, 24V dc. Run. Active when car is moving, 24V dc. With red, flashing indicator light. Door circuit. Relay with 110V ac which is activated when semiautomatichoistway doors are closed, if contacts of safety circuits have been closed previously. With indicator light: Exactly on central digit of PCB MicroBASIC display. Inspection. Active during inspection control, 24V dc. With red indicator light. Voltage applied to control. There are 3 relays. Active during normal operation. Not active during emergency control hydraulic elevators24V dc. With green indicator light. Relay opening of automatic door, gives command to open doors. Relay closing of automatic door, gives command to close doors. Ascent. Active when car initiates or realises an ascent, 24 V dc. With red indicator light. High speed. Active during high-speed run of car. No activation if elevator is equipped with speed regulation

RET : RPA :

RLB : RLDO : RLS : RM : RMP :

RMR : RMT :

ROPA : ROPC : RS : RVR :

MicroBASIC Control Board Version 2.0 May 1999

MAJOR COMPONENTS AND THEIR FUNCTION


RZS : Safety zone. Active when contact CPS terminals 00, 103is closed, and microprocessor commands bridging of door circuits, interlocks and car doors. This occurs when car is in unlocking zone (and the safety contact or circuit connected to terminals 00 and 103 is closed). If, in this case, the car is running in slow speed, control starts advanced door opening (levelling with open doors). This also happens during re-levelling with open doors. 110V ac.

Varistors (voltage limiters) V3, V4 and V5: Varistor 275V ac. A protection filter has been developed for the MicroBASIC printed circuit board. If supply with 220V ac for energising of board is higher than varistor voltage, this protection filter brings about the activation of the thermomagnetic switch. If the voltage value of 220V ac increases with respect to grounding, the filter causes activation of differential switch. V8 : Varistor 36V dc. Protects 24V entry for supply of logic part of board. Blows (FT) if voltage exceeds nominal voltage of varistor, and thereby prevents circuits from being damaged. V9 : Varistor 36V dc. Protects 24V entry for supply of other circuits which use MicroBASIC printed circuit board, receiving 24 V dc from it. Blows (FT) if voltage exceeds nominal voltage of varistor, and thereby prevents circuits from being damaged.

May 1999 Version 2.0 Control Board MicroBASIC

Chapter 3

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


ELEMENTS FOR CONFIGURATION
Microswitch bank SW1 and PL1 button are used for adjusting the parameters in the controller. They are situated in the upper left-hand area of the PCB MicroBASIC printed circuit board. By means of them the chosen parameter value may be indicated on the display with 3 digits. DIL Switches RUN Mode. Bank of [ SW.1 ] PROGRAM Mode. Bank of [ SW.1 ]

1
ON OFF

2 3 4 5 6 7 8
ON OFF

2 3 4 5 6 7 8

MICROSWITCH ( 1 ) IN (OFF) POSITION NORMAL FUNCTIONING MODE OF ELEVATOR

MICROSWITCH ( 1 ) IN (ON) POSITION FUNCTIONING MODE INPUT OF CONFIGURATION PARAMETERS

METHOD FOR PARAMETER ADJUSTMENT


General method for adjustment of parameters: Disconnect controller (thermomagnetic switch [ IG ]) and check which type of parameter shall be altered. In RUN mode (Microswitch no. 1 [ OFF ]), only 3 parameters may be changed, whereas in PROGRAM mode (Microswitch no. 1 in [ ON ] position), more than 20 different parameters may be altered. RUN mode is used if only one of the timers (TG, TE oder MTR) is meant to be changed. For this purpose microswitch no. 1 is brought in (OFF) position. By means of the 7 remaining microswitches the exact time of each timer may now be defined. Once the microswitch positions are fixed, control is once again activated (thermomagnetic switch [ IG ]), and the elevator begins normal service, operating according to the new timer values. PROGRAM mode is used for changing any other parameter. For this purpose, microswitch no. 1 is brought in (ON) position and the controller is connected (thermomagnetic switch [ IG ]). Subsequently, PCB MicroBASIC starts showing information on the three-digit display. The following steps occur in the PROGRAM mode. Once the parameters are changed, control is once again disconnected, RUN mode is actuated and timer values are defined (see previous paragraph). Finally, control is re-activated, and elevator begins normal service. That is, after changing one parameter in PROGRAM mode, control must be disconnected, RUN mode must be selected, and timers must be adjusted. Finally, control is once more connected.

RUN Mode
Normal functioning mode of elevator. Select by bringing microswitch no. 1 (microswitch bank SW1) in [OFF] position, pointing upwards). In this mode, 3 parameters may be adjusted by means of the other 7 microswitches: TG General timer (microswitch 2 - 3 - 4), timer which defines the following points: maximum door closing time (detection interlock error). time passing between end of run and initiation of the following (collective selective operation). In the universal functioning mode, this value corresponds with value of car timer. Chart : Parameter selection [TG]
1 2 3 4 5 6 7 8 SW1
ON OFF

2 Seg.

ON OFF

1 2 3 4 5 6 7 8 SW1 5 Seg.

ON OFF

1 2 3 4 5 6 7 8 SW1 6 Seg.

1 2 3 4 5 6 7 8
ON OFF

SW1 7 Seg.

1 2 3 4 5 6 7 8 SW1
ON OFF

1 2 3 4 5 6 7 8 SW1
ON OFF

1 2 3 4 5 6 7 8
ON OFF

SW1 12 Seg.
ON OFF

1 2 3 4 5 6 7 8 SW1 15 Seg.

8 Seg.

10 Seg.

MicroBASIC Control Board Version 2.0 May 1999

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


ABOUT [MTR]
MAXIMUM RUNNING TIME

TE Hall call timer (microswitches 5 - 6). Once the general timer is finished, this timer records the time, from which the elevator serves a hall call without previously chosen direction. In universal functioning mode this timer coincides with the classical hall call timer. Chart : Parameter selection [TE]
1 2 3 4 5 6 7 8
ON OFF

By means of parameter 23, PROGRAM mode these times , may be tripled (special situations).

SW1 2 Seg.
ON OFF

1 2 3 4 5 6 7 8

SW1 4 Seg.

1 2 3 4 5 6 7 8
ON OFF

SW1 6 Seg.
ON OFF

1 2 3 4 5 6 7 8

SW1 10 Seg.

MTR

Maximum running time (microswitches 7 - 8).

Defines maximum running time of elevator between two consecutive floors. If this value is exceeded, there is an error concerning maximum running time. This points to an abnormal functioning situation (for example rope slip on traction sheaves). Chart : Parameter selection [MTR]
1 2 3 4 5 6 7 8
ON OFF

SW1 8 Seg.
ON OFF

1 2 3 4 5 6 7 8

SW1 12 Seg.

1 2 3 4 5 6 7 8
ON OFF

SW1 16 Seg.
ON OFF

1 2 3 4 5 6 7 8

SW1 20 Seg.

PROGRAM Mode
In order to enter PROGRAM mode, microswitch no. 1 must be changed into bank SW1 [ON] position, pointing upwards In PROGRAM mode, more than 20 parameters may be changed, by means of which . the control functions of the installation may be adapted with accuracy. Control parameters are always adjusted at the factory. Their values are functionally adapted to the characteristics of the order. On one page of this document, the parameter values are listed, as adjusted at the factory. That is, under normal conditions it is unnecessary to modify parameters in the PROGRAM mode.

May 1999 Version 2.0 Control Board MicroBASIC

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


Modification of parameters (PROGRAM mode), using : Switch bank SW1 Microswitch .............................. No. 1 ............................ always in [ON] position PROGRAM mode. Microswitch .............................. No. 2 - 3 - 4 - 5 - 6 ...... defines binary number of parameter. Microswitch .............................. No. 7 - 8 ...................... defines new value of selected parameter.

ON OFF

SW.1 1 2 3 4 5 6 7 8

In ( ON ) position PROGRAM mode

Defines binary number of parameter :

Defines new value of selected parameter :

ON OFF

Parameter ( 0 )

ON OFF

Value ( A )

2 3 4 5 6
ON OFF
Parameter ( 1 )

7 8
ON OFF
Value ( B )

2 3 4 5 6
ON OFF
Parameter ( 2 )

7 8
ON OFF
Value ( C )

2 3 4 5 6
ON OFF
Parameter ( 31 )

7 8
Value ( D )

ON OFF

7 8

2 3 4 5 6

PL1 Button Once the number of the parameter and its new value have been selected, they are memorised by pressing of button on PCB MicroBASIC . 3 - digit display In PROGRAM mode, digits on left-hand side and in center indicate the number of the recently selected parameter, the digit on the right-hand side represents the memorised value of this parameter. That is, the new value only appears as digit on display, once it has been defined and once PL1 button is pressed, as by pressing the button the new value is memorised :

Selected parameter. Possible values : ( 00 ) ( 01 ) ... ( 31 )

Actual value of selected parameter : Possible values : (A)(B)(C)(D)

MicroBASIC Control Board Version 2.0 May 1999

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


DESCRIPTION OF PARAMETERS
PARAMETERS ADJUSTABLE IN PROGRAM MODE : PARAMETER [ 0 ] [ 1 ] : Number of floors of the installation. Functional adjustment of parameter No. 0 and parameter No. 1 to number of floors. Chart : Adjustment of parameters [ 0 ] [ 1 ] FLOORS PARAMETER [0] PARAMETER [1]

2 B A

3 C A

4 D A

5 A B

6 B B

7 C B

8 D B

9 A C

10 B C

11 12 C C D C

13 A D

14 B D

15 C D

16 D D

PARAMETER [ 2 ] : Floor on which fireman key switch is located. s Value A : Value B : Value C : Value D : Key switch on lowest floor (first floor). Key switch on 2. floor. Key switch on 3. floor. Key switch on 4. floor.

PARAMETER [ 3 ] : Type of hoistway doors. Value A : Value B : Value C : Semiautomatic hoistway door (irrespective of whether there are car doors, or whether there are none). Automatic hoistway door. Mixed, for all semiautomatic doors and for one (defined through the main floor) automatic door.

PARAMETER [ 4 ] : Function. Value A : Only 1 or 2 hall calls are accepted (Simplex or Duplex, respectively). Function according to number of floors: Up to 10 floors: Connection of calls identical with selective control, descent. Possibility of memorising 1 car call. Signalisation of hall calls (levelling) is equivalent to registration of hall calls. From 11 to 16 floors: Special connection of calls. See diagrams. Only 1 car call is accepted. Hall call signalisation levelling may be procured by adding a MS-MPX printed circuit board controlled by terminals 117, 118, 119 and 120 of parcel CH1 (PCB MicroBASIC). Maximum number of calls : Simplex : 16 Duplex : 16 Value B : Selective control, descent. Maximum number of floors : Simplex : 10 Duplex : 10 Mixed selective control. This value is valid for Simplex and Duplex elevators, versions inferior to MB134, and for Duplex from this version onwards (inclusively). In functioning mode mixed selective control several , lower floors may be defined as selective control, ascent defining the others as , selective control, descent Parameter no. 6 defines how many lower floors belong to . selective control, ascent It may be that the highest floor of those defined as . selective control, ascentreceives a call in the ascent and descent mode, the lower ones with call ascent and the higher ones , with call descent(see value B of parameter No. 5). Maximum number of floors: (1 call button on floor descent 10; (2 call buttons on floor ) descent 9. ) Selective control, ascent and descent. Maximum number of floors : Simplex : 6 Duplex : 10

Value C :

Wert D :

May 1999 Version 2.0 Control Board MicroBASIC

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


PARAMETER [ 5 ] : Type of installation. Value A : Simplex. Always fix this value in elevators with Simplex universal control, selective control, descent , selective control, ascent and descent or , mixed selective controlwith only 1 call button on floor descent (this floor must be the highest with hall call, ascent). See value C of parameter 4. Value B : Simplex, mixed selective control, 2 calls, descent. This value may only be selected if the value of parameter 4 is (C): Elevator Simplex, mixed selective control By means of this parameter several lower floors may be defined as . selective control, ascent defining the others as , selective control, descent . Value B is selected if the highest floor of selective control, ascent(as a rule, floor descent) is to be provided with a double button: ascent and descent. Thus, calls below this level will be ascentcalls, and calls above this level will be selective control, descent In this situation, . the maximum number of floors is 9. Value C or Value D : Elevator 1 or elevator 2 in Duplex. If control is Duplex, one PCB MicroBASIC must be configured with value C, and the other with value D. The assignation is indifferent, with the exception of Duplex, ascent and descent(value D for parameter 4), as hall calls descentwill be connected in (elevator 1), and hall calls ascent in (elevator 2). PARAMETER [ 6 ] : Number of floors ascentin mixed selective control . Value A : Value B : Value C : Value D : 2 floors. 3 floors. 4 floors. 5 floors. Defines the number of lower floors with ascent button in the configuration mixed selective control(see value C of parameter 4). Floors above the defined floors are provided with descent buttons. If the value of parameter 5 is B mixed selective control, 2 descent buttons on floor , the highest floor of those defined in parameter 6, there must be 2 call buttons, ascent and descent. Floors above this floor are defined as descent . See examples : PARAMETER CONNECTION HALL CALLS (CH1)

4
C
MIXED

5
A
SIMPLEX

6
B
3 F lo o r s

111 112 113 114 115 116 117 118 119 120
Floor Floor Floor

Floor

Floor

Floor

Floor

Floor

Floor

Floor

10

MIXED

C C

B
SIMPLEX 2 ON DESCENT

C
4 FLOORS
Floor Floor Floor Floor Floor Floor Floor Floor Floor Floor

10

B
SIMPLEX 2 ON DESCENT

A
2 FLOORS
Floor Floor Floor Floor Floor Floor Floor Floor Floor Floor

MIXED

10

10

MicroBASIC Control Board Version 2.0 May 1999

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


PARAMETER [ 7 ] [ 8 ] : Number of floors in lower and upper zone, respectively (asymmetric elevator) Value A : Value B : Value C : Value D : 0 1 2 3

This function is only valid for Duplex installations. It facilitates definition of how many floors one of the two elevators does not serve in the lower zone (parameter 7) or in the upper zone (parameter 8), with respect to the other elevator. Value A is selected for the elevator which arrives at all floors. The elevator which does not serve any floor receives value B, C, or D.

IMPORTANT NOTE
Both PCB MicroBASIC must have the same value for parameters 0 and 1 (number of floors of the installation), corresponding to the number of floors of the elevator which serves all of these. In an asymmetric elevator, the terminals for connection of car calls corresponding with the floors not served must be free. That is, if an elevator is asymmetric on 2 floors in the lower zone, terminals 111 and 112 of plug CC1 remain free. PARAMETER [ 9 ] : Type of elevator Value A : Traction elevator 1 or 2 speeds. Note: Jumper J2 must always be fixed in value A, B and C, as well as in D, except in traction elevators with 1 speed. Hydraulic elevator. Traction elevator speed regulation with 3VFMAC1, change 1C .

Value B : Value C :

Value D : Traction elevator speed regulation with 3VFMAC1, change 2C . PARAMETER [ 10 ] : Auxiliary timer For traction elevator. Timer for ventilation: Value A : Value B : Value C : Value D : 5 sec. 10 sec. 18 sec. 30 sec.

For hydraulic elevator. Timer delta connection: Value A : Value B : Value C : Value D : 0,2 sec. Select this value in case of direct start. 1 sec. 2 sec. 3 sec.

PARAMETER [ 11 ] : Functions auxiliary entries Facilitates definition of specific functions of auxiliary entries, terminals ( j ) and ( k ) of terminals P2, and PIN no. 20 of terminals P3. Value A : PIN ( j P2 ). STOP Function. If voltage on this PIN (+24) disappears, the controller immediately stops the elevator and remains in this condition, until once again energised, and until a car call is pressed, producing a return to normal service. During the described period no hall calls are served. PIN ( k P2 ): Unlocking zone for realisation of re-levelling. Once control decides to start re-levelling (hydraulic elevator), it analyses the voltage value on this PIN. If there is no voltage, it understandsthat the elevator is below floor level and initiates re-levelling in upward direction.

May 1999 Version 2.0 Control Board MicroBASIC

11

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


If there is a voltage of 24V dc, control knows that the elevator is above floor level and starts re-levelling in down direction. See parameter no. 24. PIN No. 20 ( P3 ) : Door close button. As soon as voltage 24V dc is applied to this PIN, the door opening timer is switched off, and closing of door is initiated immediately (only if there are car calls). Make sure that voltage appears on this pin door close button connected when door is fully opened. Instead of the , procedure described above, doors with three-phase door drive motor must be provided with a contact (normally closed) of the door opening relay. Value B : PIN ( j P2 ) STOP Function. See value A, PIN ( j P2 ). PIN ( k P2 ) : Unlocking zone for re-levelling. See value A, PIN ( k P2 ). PIN No. 20 ( P3 ) : Operation emergency power aggregate. As soon as voltage 24V dc is applied to this pin, control knows that it is being supplied by an emergency power aggregate (not by mains). Depending on the value of parameter no. 12, control will now initiate one or the other action. Value C : PIN ( j P2 ). STOP Function. See value A, PIN ( j P2 ). PIN ( k P2 ). Unlocking zone for re-levelling. See value A, PIN ( k P2 ). PIN No. 20 ( P3 ). Command to initiate re-levelling. PCB MicroBASIC initiates re-levelling, once the following factors occur simultaneously: A) Car is between floors. B) PIN no. 20 is energised with 24V dc. If parameter 11 is given any other value, re-levelling is already initiated once a) is out of car service . Value D : PIN ( f P2 ). Outlet for gong relay. Actuates gong at arrival on floor. PARAMETER [ 12 ] : Type of aggregate ( hydraulic elevator) Value A : Value B : Standard. Kleeman. Delays power failure of pump behind floor on which car is stationed (ascents) for 1 second. In this case, control is provided with a special circuit for internal connection.

12

MicroBASIC Control Board Version 2.0 May 1999

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


PARAMETER [ 13 ] : Functions auxiliary outlets Facilitates definition of the specific functions of auxiliary outlets, PINs (h) and (i) of terminal block (P2). Value A : Levelling, interlock magnet. PIN (h/ P2) activates the relay for the neutral feeder of the signal voltage of levelling It is . activated while elevator is moving in slow speed, and remains activated after end of run, until timer (TG) is finished. . PIN (i /P2) activates a relay which in turn actuates the interlock magnet. Value B : Levelling and standstill, interlock magnet. PIN (h /P2) activates the relay for the neutral feeder of the signal voltage of levellingand standstill It is activated while elevator moves in slow speed, and remains activated after end . of run, until timer (TG) deactivates after end of operation levelling It is also activated whilst . elevator is situated at floor-level, without starting a run (standstill). PIN (i /P2) activates a relay which in turn actuates the interlock magnet. Value C : Travel-direction indicator, (arrows), interlock magnet. PINs (h) and (i / P2) activate two relays for the neutral feeder of the travel-direction indicator for descent and ascent. Parameter No. 20 facilitates definition of different functional logics for the travel-direction indicator. PIN (g/ P2), PIN for signalisation (complete), except if this value is activated temporarily and deleted afterwards, during use of this PIN for connection of a relay which in turn actuates the interlock magnet. Value D : PIN (h /P2) for special hoistway signals, basically for elevators with universal function. Signal remains permanently luminous if semiautomatic door is open (contact of doors open circuit ). Intermittent signal, with intervals of 1 sec., during movement of elevator. In other situations, signals are not active. PIN ( i / P2 ) activates relay which actuates interlock magnet.. PARAMETER [ 14 ] [ 15 ] : Main floor Functional adjustment of parameters 14 and 15 to floor defined as main floor : Chart : Adjustment of parameters [ 0 ] [ 1 ] FLOORS PARAMETER [0] PARAMETER [1]

1 A A

2 B A

3 C A

4 D A

5 A B

6 B B

7 C B

8 D B

9 A C

10 11 12 13 14 15 16 B C C C D C A D B D C D D D

May 1999 Version 2.0 Control Board MicroBASIC

13

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


PARAMETER [ 16 ] : Time of return to main floor Control permits return of elevator to floor defined as main floor (floor defined in parameter 14 and parameter 15), after a certain amount of time has passed. It is possible to initiate this function only when elevator is situated on certain floors (see parameter 17). Value A : Value B : Value C : Return function to main floor not initiated. Return function initiated immediately after completing service of memorised calls. Return after 1 minute without operating.

Value D : Return after 9 minutes without operating. PARAMETER [ 17 ] : Floors on which return to main floor is initiated The function of return to main floor may be limited to a fixed number of floors on which elevator is situated. Value A : Value B : Value C : Function of return to main floor is initiated, irrespective of the floor on which elevator is situated. Function of return to main floor is initiated only if elevator is on the next floor in down direction. Only in case of the two next floors in down direction.

Value D : Only in case of the three next floors in down direction. Note: In case of hydraulic elevators, the following parameter values become obligatory for compliance with standard EN - 81.2 : Parameter 14 Value A. Parameter 15 Value A. Parameter 16 Value D. Parameter 17 Value A. For return to lowest floor after passing of 9 minutes. PARAMETER [ 18 ] : Deceleration for re-levelling Time during which elevator must be situated between floors, for initiation of re-levelling. Value A : Value B : Value C : Value D : 0.5 sec. 1 sec. 2 sec. 5 sec.

PARAMETER [ 19 ] : Deletion of car calls Control is provided with different functions for deletion of car calls. Multiple car calls may occur, due to improper handling of operating panel (example: 1 single passenger presses all car buttons). Value A : Value B : Without deletion. If this value is selected, control does not take any action in case of multiple car calls. No deletion during reversal of door circuit or photoelectric cell contact. If, by means of this system, control discovers that in 2 consecutive runs of an elevator, there has been no opening of door circuit or actuation of photoelectric barrier (in series with door open button), all car calls are deleted, as nobody has entered or left car during both runs.

14

MicroBASIC Control Board Version 2.0 May 1999

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


Value C : Maximum number of car calls: 3. Limits number of car calls which may be registered by control.

Value D : Maximum number of car calls: 6. Limits number of car calls which may be registered by control. PARAMETER [ 20 ] : Options for travel-direction indicator Value A : The travel-direction indicator is activated while elevator is moving in one direction and calls not yet served are memorised, during slow speed and until start for serving of next call (moment at which it is deactivated). If there are no calls not yet served, both arrows remain luminous, until timer (TG) is finished. Equivalent to value A, with the exception that both arrows remain luminous indefinitely if there is no memorisation of calls not yet served. Equivalent to value B, with the exception that both arrows are deactivated, if there is no memorisation of calls not yet served.

Value B : Value C :

PARAMETER [ 21 ] : Return floor Initiates return control for correction, at activation of elevator or in case of miscorrection between floors. Possible options: Value A : Correction on the lowest floor. Value B : Correction on the highest floor. PARAMETER [ 22 ] : Levelling with open doors Initiation of preopening function of doors during levelling: Value A : Value B : Not active Active Tripling time timer MTR (maximum running time and triple), TG (general timer)

PARAMETER [ 23 ] :

Option only applicable to installations with very long running times between two consecutive floors (more than 20 seconds). Value A : Value B : Value C : No. Normal option (values indicated in section RUN mode). Yes. The new values for MTR are 24, 36, 48, and 60 seconds. Triples times selected in TG, section RUN mode.

Value D : Triples MTR and TG. PARAMETER [ 24 ] : Decision criterion for re-levelling direction In this parameter, the decision criterion for direction of movement during re-levelling is defined. Value A : Value B : Re-levelling function disconnected. For terminal.

May 1999 Version 2.0 Control Board MicroBASIC

15

CONFIGURATION AND ADJUSTMENT OF PARAMETERS


Depending on the presence or absence of voltage on PIN K (terminals P2), re-levelling will be realised by control in one direction or the other : No voltage on PIN K .................. re-levelling in up direction. 24V dc on PIN K ........................ re-levelling in down direction. PARAMETER [ 28 ] : Viewing of parameters By pressing PL1 all parameters introduced sequentially may be viewed in this parameter.

16

MicroBASIC Control Board Version 2.0 May 1999

Chapter 4

INFORMATION OFFERED BY CONTROL


There are three ways in which all information offered by control, concerning installation, condition of components, etc., is supplied by PCB MicroBASIC : Indicator lights (LEDs). Display with 3 digits, controlled by button. Outlet for position indicator: Each time the position indicator in car (or hoistway) alternatively displays the two lower (lowest) floors, there is information about a grave error of the installation, which leads to a complete stop of the elevator.

INDICATOR LIGHTS
PCB MicroBASIC
D3 SC D2 SP D1 IMP NO LEVEL EMERG DL11 DL7

+5V DL9

DL10 +24V

DL8 RMT

RM DL5

DL1 RMR

RB DL3

RS DL4

RVR DL6

POINTS ON THE DISPLAY IMP : Entry of pulses from pulse generator. At appearance of voltage 24V dc on terminal 203, indicator light is switched on. In case of correct functioning, this happens 2 times, while car is moving from one floor to the next (including lowest and highest floor). Active when door circuit (and the previous safety contacts) are closed. That is, terminal 104 is energised with a voltage of 110 Vac. Active when all circuits are closed. That is, terminal 106 is energised with a voltage of 110Vac.

SP : SC :

VOLTAGE VALUES 5V : 24V : Active if there is a voltage of 5V dc for supply of microprocessor zone. In case of no voltage, check fuse (FT). Active if there is a voltage of 24V dc for supply of the relay actuation zone, as well as of all components of the installation which work with this voltage. In case of no voltage, check fuses (FF1) and (FF2).

May 1999 Version 2.0 Control Board MicroBASIC

17

INFORMATION OFFERED BY CONTROL


NO LEVEL : Green indicator light. Active while elevator is not on floor-level, levelling device closed: Terminal 207 connected to 0V dc. Red, intermittent indicator light. Only for hydraulic elevators, during operation of emergency control and only if, at initiation of emergency operation, the following points are accurate: Battery voltage is adequate (> 10 V dc) at disconnection of mains supply. All safety contacts and circuits closed Elevator is not on floor-level (jumper J1 fixed), or contact CFE, connected between terminals 5 and 0V dc, is closed (jumper J1 not fixed). Green indicator light. Active during normal operation of controller. If fuses (FF1) and (FF2) blow, indicator light is switched off. Its condition informs about the condition of relays (RMT1, RMT2 and RMT3). Red, intermittent indicator light. Active during movement of elevator. Informs about the condition of run relay (RM). Inspection control connected. Active in case of voltage 24V dc on terminal 208 Informs about the condition of relay (RMR). Active at initiation or realisation of a descent. Informs about the condition of relay (RB). Active at initiation or realisation of an ascent. Informs about the condition of relay (RS). Active during initiation or realisation of a high-speed run. Informs about the condition of relay (RVR). (inspection switch activated).

EMER :

RMT :

RM : RMR :

RB : RS : RVR :

DISPLAY WITH 3 DIGITS


On the 3-digit display, full information about a multiplicity of data concerning the elevator is indicated. Denomination of digits :

C
Display on PCB MicroBASIC

INDICATION OF SPECIAL INFORMATION


Specific information is provided in special situations : Activation of control: At activation of control the number of the software version is displayed for 3 seconds. Always indicate the number of the respective software version when contacting the MP group about any technical problem concerning control. Return process correction While elevator is being returned, : effects correction at final floor , information concerning position of elevator appears on display (flashing). Error in installation: Irrespective of the information actually on display, any error occuring in the installation is displayed, until PL1 button is pressed. The error remains memorised, for later display.

18

MicroBASIC Control Board Version 2.0 May 1999

INFORMATION OFFERED BY CONTROL


STANDARD INFORMATION
Different blocks of information are shown on display. In order to proceed from one block to the next, press PL1 button for a short time. Once the last block is on display, renewed pressing of button leads to return to 1. block of information: Block 1 : Car position. Reasons preventing movement of car. Floor and type of call served by car. Block 2 : Memorised car calls. Block 3 : Memorised hall calls descent . Block 4 : Memorised hall calls ascent . Block 5 : Conditions of elevator components. Block 6 : Memorised errors.

DESCRIPTION OF BLOCKS OF INFORMATION


Block 1 : Alternating information about position of car.

0
(0) indicates viewing of position of elevator

X
Position of car

Viewing of information while elevator is not moving: Number of the component which mainly prevents movement of elevator, and position of elevator, are displayed alternatingly.

0
The (A) indicates the component which mainly prevents movement of elevator

X
No. of installation component the condition of which prevents movement of elevator

Display of information during movement of elevator: Alternating information about type of call and floor served by elevator, and about actual position of elevator :
SERVES CAR CALL ON FLOOR 7

SERVES HALL CALL DESCENTON FLOOR 8

SERVES HALL CALL ASCENTON FLOOR 4

May 1999 Version 2.0 Control Board MicroBASIC

19

INFORMATION OFFERED BY CONTROL


Block 2 : Informs cyclically about all memorised car calls. The following figure shows the manner in which car calls to floors 2, 5 and 9 appear on display :

1 sec.

1 sec.

Block 3 :

Informs cyclically about all memorised hall calls descent The following figure shows . the manner in which memorised hall calls descentto floors 3, 7, 8 and 10 appear on display :

1 sec.

1 sec.

1 sec.

Block 4 :

Informs cyclically about all memorised hall calls ascent The following figure shows the . manner in which memorised hall calls ascentto floors 1 and 6 appear on display :

1 sec.

1 sec.

Block 5 :

Conditions of elevator components. This block contains information about the conditions of the different components of the installation. Each component is provided with a number. If this number is flashing, the respective circuit is open, not active; if the number is not flashing, the circuit of the component is closed or connected. Once this block is entered, indication is as follows :

N o in f o r m a tio n is d is p l a y e d in th e s e d i g i t s

If you wish to enter this block, wait 2 seconds until appearance of the following :

20

MicroBASIC Control Board Version 2.0 May 1999

INFORMATION OFFERED BY CONTROL


IMPORTANT NOTE ABOUT VIEWING
If digits are blinking, condition of component is contrary to value indicated in chart.

T h a t is , in f o r m a tio n is b e in g p r o v id e d c o n c e rn in g t h e c o n d itio n o f c o m p o n e n t n o . 1 . B y p re s s in g o f P L 1 b u tto n t h e o t h e r c o m p o n e n t s m a y b e v ie w e d c o n s e c u tiv e ly, u n til th e la s t o n e i s r e a c h e d . A t re n e w e d p r e s s in g o f b u tto n t h e ( E ) a p p e a r s w i t h o u t i n f o r m a tio n . If b u tto n is n o t p r e s s e d a g a in a fte r w a r d s , w e r e m a in in b lo c k 5 ; if b u tto n i s p r e s s e d o n c e a g a in , w e e n te r b l o c k 6 :

()
PRESS

PRESS

DO NOT PRESS

PRESS

PROCEED TO NEXT BLOCK

L e a v e P L 1 b u tto n p r e s s e d fo r s e v e r a l s e c o n d s , i n o r d e r t o a r r i v e a t p o i n t ( ) m o r e q u i c k l y .

VIEWING OF CONDITIONS OF ELEVATOR COMPONENTS

The (E) indicates condition

Number of elevator component: Not flashing: Circuit closed or connected Flashing: Circuit open or disconnected

Block 6 :

Memorised errors and defects. In this block, the last 64 errors and defects which have occured in the installation may be viewed. At occurence of a new error it appears on display, irrespective of the block which is actually being viewed, and is memorised on PCB MicroBASIC. In the process, the oldest memorised error is deleted (if already 64 errors were memorised). At entry into this block of information the error which has occured last appears first. This means that the errors indicated start with the youngest and finish with the oldest. Each error is provided with a number informing about its age. Accordingly, error no. 3 must have occured after no. 5.

May 1999 Version 2.0 Control Board MicroBASIC

21

INFORMATION OFFERED BY CONTROL


TECHNIQUE OF REPRESENTATION OF ERRORS

PREVIOUS BLOCK

PRESS

PRESS

FOLLOWING BLOCK

DO NOT PRESS

1 sec.

1 sec.

AGE OF ERROR

ERROR CODE

FLOOR ON WHICH ERROR OCCURED 01 : LOWEST FLOOR

The following information is displayed cyclically, with an interval of 1 second : A) Age of error and error code. B) Floor on which it occured. If (PL1) button is pressed for less than 1 second, the next error (older than the previous one) appears, and so forth. If (PL1) button is pressed permanently at display of any error, the following appears :

PRESS

FOLLOWING BLOCK

DO NOT PRESS

VIEWING OF ERRORS

B y re le a s in g o f b u t t o n a n d r e n e w e d p r e s s in g t h e f o l l o w i n g b l o c k i s e n t e r e d .

22

MicroBASIC Control Board Version 2.0 May 1999

Chapter 5

CONTROL FUNCTIONS
This chapter deals with the following points: Basic functional steps Description of special functions Functional problems Knowledge of the information offered by control, listed in detail in chapter 4, is prerequisite for any practical use of the following information. The information offered by control appears in the shape of indicator lights (LEDs), and on displays with 3 digits.

BASIC FUNCTIONAL STEPS Luminous sequence


Actuation of main switch leads to the following : IG LED indicator light (DL9) + (5V) on, red: supply in microprocessor zone. LED indicator light (DL10) + (24V) on, red: supply with 24V dc. LED indicator light (DL8 , RMT) on, green: supply with 24V dc correct. These 3 LED indicator lights must always be active during normal operation. In the course of 3 seconds after the luminous sequence, a number corresponding with the software version appears on the 3 displays. Always keep this number ready when contacting the MP group (technical department).

Return control (connection on final floor)


Characterised by the following points: The information of block 1 indicated on display is blinking, during movement the following appears : Both indications are blinking.

1 sec.

Criterion direction of correction


If car is situated on intermediate floors, correction is effected on furthest floor, as defined in parameter no.21 (value A: lowest floor; value B: highest floor). If car is situated in outer zones (upper or lower), with open prelimit switch and without levelling (contact 207 0V dc closed) : Lower prelimit switch open: car is sent to 2. floor. Upper prelimit switch open: car is sent to penultimate floor. If car is situated in outer zones (upper or lower), with open prelimit switch and with levelling (contact 207 0V dc open), there is no movement of the elevator, and in 1. block of information (position of elevator) the position of the elevator is indicated. After completion of return control, information is displayed in block 1 (position of elevator), not flashing. Return control always begins after luminous sequence, when the elevator undergoes a miscorrection (example: through lack of pulses), and after completion of an inspection control. All other indicator lights and relays are connected as in normal control.

May 1999 Version 2.0 Control Board MicroBASIC

23

CONTROL FUNCTIONS
Normal control
Once the elevator is stopped, the following information alternatingly appears on the displays: In case of semiautomatic hoistway doors.

1 sec.

ACTUAL POSITION OF CAR

In case of automatic hoistway doors.

1 sec.

ACTUAL POSITION OF CAR In the first case, there is indication of door circuit being closed (central point on display active): SP (door circuit), and of there being no possibility for starting, as door contacts are not closed (A08); logical, as in this case, there is no closure (whereby interlock magnet is actuated or car doors are closed), as long as there is no door movement. In case of automatic hoistway doors, door circuit is bridged (central point on display always active). At closing of interlock circuit, display-point on left-hand side is activated. This is normally the case, as elevator is stationed with closed doors. The information (AAA) shows that elevator is ready for service and capable of realising any requested run. It may happen that the information does not appear as described above. For example: The central display-point is not active (SP): indicates that door circuit is open. (A08) or (AAA) do not appear: another cause prevents readiness for service (example: (A07) photoelectric barrier in car covered). See code chart/components which prevent run of elevator in chapter 5. If a call is actuated in this situation, and the elevator is ready to serve this demand, the normal sequence is as follows: Closure of car door and actuation of interlock magnet. For this purpose, relay (ROPA) is deactivated, and relay (ROPC), as well as high-speed relay (RVR, LED DL6), are activated. In case of traction elevators, relay ascent (RS, LED DL3) or relay descent (RB, LED DL4) are activated, whereby the corresponding contact (relay) is connected. If there is an interlock magnet, the external relay of PCB MicroBASIC, (RLE), is connected. In case of hydraulic elevators, only relay (RLE) which actuates the interlock magnet is connected. Once all circuits are closed (display-point on left-hand side active, interlock circuit), relay , with RM intermittent, red LED indicator light: DL5 is activated. In case of hydraulic elevators, RS, with , DL3 LED indicator lightor RB, with DL4 LED indicator light is activated. , In case of hydraulic elevators, relay (RET, without LED indicator light, in the upper left-hand corner of the relay block on PCB MicroBASIC) produces the delay between the main switch relay (CG) and run (CM, direct start) or the time of the star phase (star/delta start). During movement, information block 1 on displays alternatingly shows actual position of elevator, and type of call as well as floor served. Between two floors, the photoelectric barrier (fork) receives 2 pulses each time. These appear on the display-point on the right-hand side (IMP). Furthermore, the DL11 (NO LEVEL) LED indicator light is active (green) the whole time, with the exception of the short moment of levelling at each stop.

24

MicroBASIC Control Board Version 2.0 May 1999

CONTROL FUNCTIONS
At change of speed (once the last pulse of the photoelectric barrier (fork) is reached), relay (RVR, LED DL6) is deactivated. During the whole distance in slow speed, information block 1 of the displays has the following indication :

1 sec.

ACTUAL POSITION OF CAR

Once the point of levelling is reached (contact 207: 0V dc, open), LED indicator light (DL11 NO LEVEL) is switched off and relay (RM, intermittent LED indicator light DL5) drops. Shortly afterwards, relay ascent RS, red LED indicator light (DL4) or relay descent (RB, LED indicator light DL3) also drops. Inspection control Inspection control is initiated by actuation of inspection switch. By means of this switch the circuit between terminals 24V dc and (208) is closed: Relay of PCB MicroBASIC is activated (RMR, LED indicator light DL1). Any activity of control just taking place is stopped. Car and hoistway doors (if open) are closed. Block 1 of the displays has the following information:

1 sec.

INDICATES THAT INSPECTION CONTROL IS OPERATING

If, for example, (A06) appears instead of (AAA), information is provided that car may not be moved in inspection control, as door circuit is open, see relation between codes/ the component which prevents movement, in document 4. In order to make the elevator move in inspection control, the same point (terminal) (208) is used as operating panel (ascent and descent) which at actuation of buttons for last and first car call, respectively, is supplied with (24V dc).

PLEASE NOTE .. ! : During inspection control, elevator may not be moved further than prelimit
switches; that is, once, during ascent, the upper prelimit switch is reached, the elevator stops and is only able to continue in down direction. Indication of information on display (block 1). At pressing of ascent the following appears :

1 sec.

CAR MOVES UPWARDS DURING INSPECTION

May 1999 Version 2.0 Control Board MicroBASIC

25

CONTROL FUNCTIONS
ABOUT INSPECTION
At each pressing of ascent or descent (during inspection) the following appears, respectively: (SSS) or (bbb). If car is not moving, movement is prevented by a component; that is, in this last case, (AAA) does not appear, but instead a code is displayed indicating the component which prevents movement (for example: (A08), interlock circuit or car door circuit open).

At pressing of descent the following appears :

1 sec.

CAR MOVES UPWARDS DURING INSPECTION

In order to change from inspection control to normal function, change inspection switch (contact between 208 and 24V dc is opened), disconnect relay (RMR, LED DL1) and actuate correction control.

Emergency control (only for hydraulic elevators)


In case of hydraulic elevators, MicroBASIC control is provided with a thermomagnetic switch (IB, 6A) which must always be activated, except if control will not be operating for a longer period. Thus, the battery may be recharged by means of PCB MicroBASIC loader during normal function, and will be able to supply energy in case of emergency control. Normal voltage of battery must be between 13 and 13.8V dc (except in unloaded condition). Check regularly for correct voltage. PCB MicroBASIC is provided with a drain sensor for the lower battery voltage. Once this voltage reaches a value of 9V dc, emergency control is disconnected and stopped. Emergency control may be actuated in case of the following : Power failure (energy supply from mains disconnected), therefore LED indicator lights (RMT, DL8), (24V, DL10) and (5V , DL9) are switched off. Thermomagnetic switch (IB, 6A) is activated. There must be a factor informing about end of emergency control. There are two possibilities : A ) Emergency control is finished once elevator has reached next floor in down direction. For this purpose, magnet switches 326, 327, 328 or photoelectric barrier (fork) (MAC 523/12) may be used: Supply is from points (+12F) and 0V dc, and their outlet (NIVELADOR) (=levelling device) is connected to terminals 207 and 0V dc. In this case, jumper J1(lower right-hand area of PCB MicroBASIC) must be fixed. LED indicator light (NO LEVEL, DL11, green) is always luminous while elevator is between floors. That is, in this case, elevator will only realise emergency control if LED indicator light (NO LEVEL) is active. B ) In the second case, emergency control is completed at any other point of the run of the elevator, generally on the lowest floor. In this context, the following points must be accurate: Do not fix jumper J1 (lower right-hand area of PCB MicroBASIC). Install additional contact in hoistway which is connected to terminals 5 and 0V dc and normally closed. Opening of this contact leads to end of emergency control. In addition to the points mentioned, it is necessary that all contacts of the safety circuit are closed, so that emergency control may be carried out. If all previously mentioned points are accurate, there is a voltage of (12Vdc) which is the voltage the battery has at this moment, minus the voltage drop on cables at terminals 281 (+) and 280 (-) (points of connection of emergency valve). Indicator light (EMER, LED indicator light DL7 , red, intermittent) is switched on while outlet for emergency valve is energised. (NO LEVEL) indicator light stays on, until elevator is at floor-level.

26

MicroBASIC Control Board Version 2.0 May 1999

CONTROL FUNCTIONS
DESCRIPTION OF SPECIAL FUNCTIONS
Repeated door close or interlock error Control realises closing of doors and actuation of interlock magnet during a maximum time (TG). If circuit cannot be closed, command is given to open doors, and/or interlock magnet is disconnected. This is followed by a renewed attempt at closing, and accordingly up to 12 times. If circuit cannot be closed, elevator changes into condition called temporary out of service FST On PCB MicroBASIC display, . error F05 is indicated which remains memorised for later display. In this situation, the elevator does not serve any hall calls. In order to return to normal function there must be a car call. Interruption of photoelectric barrier in car or opening of automatic hoistway door If ray of photoelectric barrier in car is interrupted (if door open button is pressed or microswitch for door sensitivity is open) or semiautomatic hoistway door remains open for more than 48 seconds, elevator changes into a temporary out of service and does not serve any hall calls (error F12 or F11 are indicated, respectively). In order to return to normal function it is sufficient that the respective component change into the closed circuit condition for five consecutive seconds. Repeated door close or interlock error If car is provided with automatic hoistway doors, and if it is stopped with closed doors, doors may be opened : From outside : By pressing of call button. From car : By pressing of door open button or of call button for the floor on which car is situated.

If doors are just being closed for running, closure may be interrupted : From outside : By pressing of call button corresponding with service defined as next service to be carried out by car From car : By interrupting ray of photoelectric barrier, by actuating microswitch for door sensitivity (presence of obstacle), or by pressing of door open button or of call button of the floor on which car is situated.

In this case, door opening time is equivalent to door closing time, plus 2 seconds. After the end of a run, command is given to open doors within a fixed time (TG). Once this time has passed, command is given to close doors, if calls not yet served are memorised or if hoistway doors are automatic. Fireman control MicroBASIC control permits connection of 2 fireman key switches, one in hoistway and one in car. s Fireman key switch in hoistway s Is usually located on main floor of building. Activation by closing of circuit between terminals (10, CH2) and (+24 CH1). If fireman key switch is actuated while elevator is moving, elevator stops run at next floor and s starts in direction of the floor, on which fireman key switch is located, without opening doors. If no stop s was necessary (as the actual direction of movement is adequate for reaching floor of fireman key s switch), all calls are simply deleted, and the elevator is brought to floor of fireman key switch. s

May 1999 Version 2.0 Control Board MicroBASIC

27

CONTROL FUNCTIONS
ABOUT ASYMMETRIC ELEVATORS
In both elevators parameters 0 and 1 (number of floors of the installation) must be configured with the same value. This value coincides with the total number of floors of the installation. The displays for binary input connected to both controllers must have the same programming (sequence). This must also coincide with the total number of floors of the installation. In parcel for connection of car calls (CC1), terminals corresponding with floors on which elevator does not stop (in case of absence of button on car operating panel) must remain free.

If, at actuation of fireman key switch, elevator is stationed on fireman floor, doors always remain s open. In this situation, no call is served (neither hall calls, nor car calls), until fireman key switch is no s longer actuated, neither in car, nor in hoistway. Fireman key switch in car s Activation by closing of circuit between terminals (9, CC2) and (+24, CC1). Fireman key switch in car may only be actuated, once key switch in hoistway is activated and s elevator is stationed. If installation is provided with fireman key switch in hoistway, but there is none in car, terminals (9, s CC2) and (+24, CC1) must be bridged. This leads to the same effect as if fireman key switch in car had s been actuated permanently. Procedure after activation of fireman key switch in car: s Once elevator is stopped with open doors, no call is served. After activation of key switch in car, a call on car operating panel (car call) may be served, but no further calls will be registered and no hall calls will be served. Closing of doors is controlled by pressing of car call button. While button remains pressed, doors close. However, if it is released before complete closure, doors begin once again to open. Once closure is completed (elevator starts moving), no further pressing is necessary. Fireman control is finished, once key switch in hoistway is deactivated. If there is key switch in car, s it must also be deactivated, in order to make sure that there will be no undesired operations at later actuations of fireman control. Mixed selective control This function is only applicable in case of Simplex control. In addition to the current functions of selective control, descent and ascent, MicroBASIC facilitates operation in mixed selective control. Several hall calls to lower floors may operate as selective control, ascent. The remaining higher floors then operate as selective control, descent. This may for example be useful in case of buildings with garages. Configuration technique : PARAMETER 4 : PARAMETER 5 : With value C, operates in mixed selective control. With value B, facilitates provision of the highest floor of those configured as selective control, ascent, with 2 hall call buttons, one for ascent and one for descent. In order to achieve this function, parameter 4 must have value C. Defines number of lower floors which operate in mixed selective control.

PARAMETER 6 :

Mixed selective control is applicable to buildings with up to 10 or 9 floors, thus parameter 5 receives value B (two hall call buttons on main floor). Asymmetric elevators This function is only applicable in case of Duplex control. If one of the elevators of a Duplex installation has no access to any one floor, it is called asymmetric. PARAMETER 7 : PARAMETER 8 : Defines number of floors in lower zone on which elevator does not stop. Defines number of floors in upper zone on which elevator does not stop. That is, asymmetry may occur in lower and upper zone; moreover, one elevator may be asymmetric on lower floors and the other may be asymmetric on upper floors.

28

MicroBASIC Control Board Version 2.0 May 1999

CONTROL FUNCTIONS
Operation emergency power aggregate This function is only applicable to Duplex elevators. If parameter 11 is configured with value B, there is a special entry to control, informing control about whether energy to motor is supplied by conventional mains or by an alternative emergency function (example: emergency power aggregate). Once entry is connected to (+24), control understands that there is a case of emergency (function emergency power aggregate active). It operates in the usual manner, with the exception that calls , not yet served are only served once the other elevator is stopped. In this manner, the emergency function only provides energy for one elevator at a time. Deletion of car calls Car calls registered due to improper handling of car operating panel are deleted automatically (example: a single person presses all call buttons). By means of parameter 19 this function may be activated with the following options: Value A : Value B : Function not activated, no deletion of car calls. Deletes all registered calls, if in two consecutive runs circuit of semiautomatic door (connection 103/104) does not open or contact of photoelectric barrier in car (connection 2/24V dc) does not change over. This option must not be used if elevator has neither semiautomatic hoistway doors, nor a photoelectric barrier in car. Registration of up to 3 or 6 car calls, respectively.

Value C/D :

Re - levelling

FZS

E
RE-LEVELLING DURING DESCENT

FB
ZONE (CPS) ZONE (CPS)

D C B A

FS

FLOOR RE-LEVELLING DURING DESCENT

K2 00
Relation to MicroBASIC control :

K3

K1 103

Door zone. Zone which defines moment at which car stops. Established by contact connected to terminals 207 and 0V dc (levelling device) : Open : Closed : Within door zone. Outside of door zone.

May 1999 Version 2.0 Control Board MicroBASIC

29

CONTROL FUNCTIONS
Re-levelling zone: Once car reaches this zone, control is informed that re-levelling must be initiated. Conventionally, this function is fulfilled by means of the same levelling component (levelling device) and/or contact of safety zone, in order to keep the number of components in hoistway as low as possible. As standard in MicroBASIC, re-levelling is initiated at leaving of door zone, that is, when contact between terminals 207 and 0V dc (levelling device closed) closes. Normally, this solution is acceptable. Exceptions are cases in which door zone is very short (hydraulic elevators with great stopping precision) and/or in which frequency and risk of misregulation are very high (example: hydraulic car elevators). For such situations, there is an entry by means of which, at energising with 24 V dc, control is informed that re-levelling zone is reached (only in this case re-levelling begins). For this purpose parameter 11 must be configured with value C. In this case, an additional component must be fixed in hoistway which closes contact (by energising with 24 V dc at entry). Re-levelling direction. If car escapes from door zone in up direction, re-levelling must occur in down direction. If car escapes in down direction, re-levelling must occur in up direction. Depending on the value of parameter 24, controller offers two possibilities for re-levelling : Value A : Re-levelling function deleted. Selected if there shall be no re-levelling of elevator (generally in case of traction elevators). For traction elevators 1 speed always select value A. Value B : By means of terminal. Special input indicating that, depending on the voltage applied, elevator chooses one or the other direction for re-levelling : No voltage: Re-levelling in up direction. 24V dc: Re-levelling in down direction. Normally, in case of hydraulic elevators, parameter 24 is given value B. If there is only re-levelling in up direction, no additional component needs to be installed. Safety zone. Zone within unlocking zone of hoistway doors in which a safety contact or circuit may be fixed for bridging of door circuits, interlock and car (connections 103, 104|104, 105|105, 106), so that re-levelling will take place with open doors (EN-81). Safety zone is defined by its safety contact or circuit which is connected between terminals (00) and (103) : Safety circuit open: outside of safety zone. Safety circuit closed : within safety zone. PCB MicroBASIC always connects terminals (00) and (106) internally (thereby bridging door circuit, interlocks and car), when re-levelling is initiated or when car finishes slow-speed run (see special function levelling with open doors ). If at beginning of re-levelling, there is a voltage of 110 V ac on terminal (00, that is, a safety contact or circuit is bridged (103 with 00)), controller starts re-levelling, without changing condition of doors. Further features of re-levelling in MicroBASIC control systems : Parameter 18 permits delaying initiation of re-levelling. Control always effects re-levelling as quickly as possible. In certain situations re-levelling control is not actuated, as this would make no sense in practice (example: elevator initiates new run). The installation (levelling device 538)+ kit magnetic switch (magnetic kit) 327/328, is provided with all functions for re-levelling and for levelling with open doors. These functions are applicable to hydraulic elevators as well as to traction elevators.

30

MicroBASIC Control Board Version 2.0 May 1999

CONTROL FUNCTIONS
Levelling with open doors Parameter 22 permits decision about whether this function is to be actuated. Levelling with open doors may be realised during slow speed of car (in levelling zone). A safety contact or circuit must be used which informs about door unlocking zone and which in turn bridges door circuits, interlocks and car (terminals 103, 104|104, 105|105, 106). Connection at points (00) and (103, of CC2). This component is also used for re-levelling with open doors. During slow-speed run, PCB MicroBASIC tests voltage on terminal (00). If there is 110 V ac, this terminal is connected internally with (106, thereby bridging circuit), and command is given to open doors. Stopping on lowest floor (hydraulic elevators) If elevator remains stationed for more than 7 minutes without running, it is automatically returned to lowest floor. Only in case of hydraulic elevators. Grave errors ( F1 | F2 | F3 | F4 | F9 | F14 | F10 | F15 | F16 | F17 | F26 | F27 ) If there is a grave error in the installation, so that the elevator may not carry out any further runs, it changes into a permanent out of service immediately after discovery of grave error. In this case, , the error (Fxy) appears on the PCB MicroBASIC displays. The error is memorised for later displays. On the car display (and/or display in hoistway, if existing) the 1. and 2. floors are indicated. Stopping for opening and subsequent closing on final floor (hydraulic elevators, error F03) If, after reaching of final floor and opening of final limit switch, car starts another run (final limit switch is closed), car is stopped on lowest floor, and no further runs will be carried out. It changes into a permanent out of service. On display, error (F03) is indicated.

VERY IMPORTANT NOTES


The controller analyses this situation by testing voltage on terminal (103). That is, we definitely discover when any contact (not only the final limit contacts) between terminals 102/220 or 103 opens for more than about 3 seconds. This function only operates in hydraulic elevators, during normal function or in case of fireman control (not during inspection). By changing over of inspection switch permanent out of service may be annulled.

May 1999 Version 2.0 Control Board MicroBASIC

31

AFFILIATED COMPANY MP THE ARGENTINE


San Antonio, 1111/15/19 Capital Federal Buenos aires - The Argentine Tf. +54.1.3027877 Fax. +54.1.3032321 e-mail : alera@mparg.com.ar Contact : Mr. Abraham Lera

MP THE NETHERLANDS
Drukkersweg, 6 2031 EE Haarlem - The Netherlands Tf. + 31 (0) 23 5477834 Fax. + 31 (0) 23 5477839 e-mail : postbus@macpuarsa.demon.nl Contact : Mr. Rowan Lebbink

MP AUSTRIA
Triesterstrasse, 14 2351 Wiener Neudorf - Austria Tf. + 43 2236 865626 Fax. + 43 2236 86562620 e-mail : mp.austria@ikano.at Contact : Mr. Alvaro Rein

MP POLAND
UL Dozynkowa, 9 H61-662 Poznan - Poland Tf. +48.61.8266033 Fax. +48.61.8266033 e-mail : handle@prolift.com.pl Contact : Renata Jezewicz/Wieslaw Mielcarski

MP BRAZIL
Av. Guido Caloi, 1985, G-8 CEP 05802 - 140 Capela do Socorro/Sao Paulo, SP - Brazil Tf. + 55 11 58903338 / 58911245 Fax. + 55 11 58903308 e-mail : jlhc@uol.com.br Contact : Mr. Juan Lpez Herrera

MP PORTUGAL
Rua das Lasge, 166; Z. Ind. San Caetano Valadares, Oporto - Portugal Tf. + 351 2 7117971 Fax. + 351 2 7120949 e-mail : diginorte@esoterica.pt Contact : Mr. Jos Guerra

MP CHINESE
N.1003, The Gateway Building 10, Yabao Road, Chaoyang District 100020 Beijing - Chinese Tf. + 8610 65915851 Fax. + 8610 65915852 e-mail : puarsagm@mailhost.cinet.com.cn Contact : Mr. Guillermo Maestre

LISBOA Subcidiarie
Bairro 16 Novembro, lote 50 1sq. Tires 2775 Parede - Lisboa Subcidiarie Tf. + 351 1 4843078 Fax. + 351 1 4843087 Contact : Mr. Jos Guerra

MP CZECH
Porcansk 465/3 194 00 Praha 9 Czech Republic Tf. + 420 2 90051417 Fax. + 420 2 861518 e-mail : prada@terminal.cz Contact : Mr. Pavel Dvorsk

MP SOUTH AFRICA
28 Visagie Street, Guaranty House 2 floor Pretoria Central - South Africa Tf. + 271 2 3253234 Fax. + 271 2 3256266 e-mail : Contact : Mr. Tony Barbosa

MP DEUTSCHLAND
Krokusstrasse 9 D - 12357 Berlin - Deutschland Tf. + 49 30 66 06 100 Fax. + 49 30 66 06 10 60 e-mail : berlin@mp-deutschland.de Contact : Mr. Peter Erdmann

MP CHILE
Edificio Puerto 1 Local 3 San Francisco 251 - Santiago (Centro) - Chile Tf. + 56 2 3611982/83 Fax. + 56 2 3611984 e-mail : mpchile@entelchile.net Contact : Patricio Mora

MP GREECE
461, Irakliou Ave. 14122 N. Iraklio, Athens - Greece Tf. + 30 1 2840155 Fax. + 30 1 2845183 e-mail : macpuhel@netor.gr Contact : Mr. Juan Ant. R. Toquero

MP THAILAND
Suite 1401, level 14, 140 One Pacific Place Sukhumvit Road Bangkok 10110 - Thailand Tf. + 66 2 6535036 Fax. + 66 2 6535130 e-mail : simeric@ksc.th.com Contact : Mr. Eric Tanguy

MP ITALY
Via Lodi, 1 Muggio, Milano - Italy Tel. + 39 039 792100 / 792154 Fax. + 39 039 791912 e-mail : mp.italia@galactica.it Contact : Mr. Alberto Sordi

MP UNITED KINGDOM
13/14 Chartwell Business Centre The Avenue Bromley, Kent BR1 2BS - United Kingdom Tf. +44 (0) 20 8466 0810 Fax. +44 (0) 20 8466 0737 e-mail : postbox@mpuk.demon.co.uk Contact : Mr. Gary Gilbertson

MP TURKEY
Kartal Caddesi, 71 B1450 Yakacik - Istambul - Turkey Tf. + 90 216 3772880 Fax. + 90 216 3094392 e-mail : cigdem6@ibm.net Contact : Mr. Tibet

BRANCH OFFICE IN SPAIN MP BARCELONA


Pol. can Parellada, c/ Coln 485, nave 10 08228 Les Fonts de Terrassa - Barcelona Tf. + 34 93 7317333 Fax. + 34 93 7310838 e-mail : mpbarna@macpuarsa.es Contact : Mr. Daniel Rodriguez

MP MADRID
Pol. Fin de Semana, c/ Gumersindo Llorente, 62 28022 - Madrid Tf. + 34 91 3294943 Fax. + 34 91 3293719 e-mail : mpcentro@macpuarsa.es Contact : Mr. Enrique Fuentes

MP BILBAO
Pol. San Lorenzo, Pabelln 5 48930 Beda - Vizcaya Tf. + 34 94 6313585 Fax. + 34 94 6313529 e-mail : mpnorte@macpuarsa.es Contact : Mr. Octavio Prez

MP VALENCIA
Pol. n1 de Catarroja, c/ Proyecto 32, nave 2C 46470 Catarroja - Valencia Tf. +34.96.1272540 Fax. +34.96.1272528 e-mail : mplevante@macpuarsa.es Contact : Mr. Javier Lera

Pol. Navisa, Calle E. Tfno. : + 34 95 4630562 Fax : + 34 95 4657955 41006 Seville. SPAIN

Technical Dossier
v0.00, JULY 01 English / MSCM02Uk

Installation Assembly Start-Up Use Maintenance Repair

Lift SCM 02

GENERAL TABLE OF CONTENTS


Chapter 1 PASSENGERS RESCUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Procedure for a Passengers Rescue Operation in a SCM Lift. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2 Procedure for opening landing doors with the emergency key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Chapter 2 INSTALLATION AND ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 The Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Materials Unloading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 Life Rope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 Shaft Ranging and Check-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 Shaft Supports Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6 Guides Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7 Machine Bedframe Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8 Bedframe Assembly Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9 Placing the Machine On the Bedframe . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10 Securing the Electric Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11 Carrying Out the Electrical Installation of the Machine . . . . . . . . . . . . . . . . 2.12 Executing the Connection of the Revision Hose . . . . . . . . . . . . . . . . . . . . . 2.13 Car and Counterweight Frame Assembly (wedge boxes should be assembled) 2.14 Traction Ropes Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15 Machine Pulley Covers Kit Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.16 Instructions for Weights in the Counterweight Frame . . . . . . . . . . . . . . . . . 2.17 Assembly of the Speed Governor and its Rope in the Car . . . . . . . . . . . . . . 2.18 Car and Counterweight Buffer Support Pillars Assembly . . . . . . . . . . . . . . . 2.19 Doors Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.20 Car Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.21 Doors Operator Assembly in the Car . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.22 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 6 6 7 7 11 12 16 17 18 19 20 20 21 22 24 24 24 25 26 26 27 27

Chapter 3 COMMISSIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.1 Checks and Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.2 Car and Counterweight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Chapter 4 USE OF THE LIFT SCM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 Purpose of These Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 The Intended Use of the Lift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3 Types of Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.1 Simplex Automatic Control Unit . . . . . . . . . . . . . . . . . . . . . 4.3.2 Simplex Collective Control Unit in Descent . . . . . . . . . . . . . . 4.3.3 Simplex Collective Control Unit in Ascent and Descent . . . . . 4.3.4 Duplex Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.5 Duplex Collective Control Unit in Descent . . . . . . . . . . . . . . 4.3.6 Duplex Selective Control Unit in Ascent and Descent . . . . . . . 4.4 Information on the Normal Use of the Lift . . . . . . . . . . . . . . . . . . . . . . 4.4.1 Keep the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.2 Situations that Require Professional Intervention . . . . . . . . . 4.4.3 Entering and Exiting Safely . . . . . . . . . . . . . . . . . . . . . . . . 4.4.4 Lift Accesses Free from Obstacles at The Landings . . . . . . . . 4.4.5 Open Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.6 Control Unit Cabinet / Upper Floor . . . . . . . . . . . . . . . . . . . 4.4.7 Description of the Different Control Unit Cabinet Components 4.4.8 Use of the Emergency Key . . . . . . . . . . . . . . . . . . . . . . . . 4.4.9 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . 5.1 Description of Components . . . . . . . . . . . . . . . . 5.2 Lift Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4 Landing Doors . . . . . . . . . . . . . . . . . . . . . . . . 5.5 Ropes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5.1 Procedure for Replacing the Ropes . . 5.6 Machine and Bedframe . . . . . . . . . . . . . . . . . . 5.6.1 Procedure for Replacing the Machine 5.6.2 Procedure for Replacing the Pulley . . 5.7 Speed Governor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 34 34 36 36 36 36 36 37 37 38 38 38 38 38 38 38 38 39 39 40 40 41 41 41 42 43 43 43 44 44

v0.00, JULY 01

Page 2 / 46

MSCM02UK

Lift SCM 02

5.8 Buffers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9 Alarm Device and Emergency Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.10 Rescue System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.10.1 Checks and Tests To Be Carried Out During the Maintenance Inspections of 5.10.2 Checks and Tests on the Car and Access to the Car . . . . . . . . . . . . . . . . 5.11 Counterweight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.11.1 Checks and Tests on the Counterweight . . . . . . . . . . . . . . . . . . . . . . . . 5.12 Guide Shoes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.13 Safety Gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.13.1 Checks and Tests on the Safety Gear . . . . . . . . . . . . . . . . . . . . . . . . . . 5.14 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.15 Load Weighing Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.15.1 Checks and Tests on the Load Weighing Device . . . . . . . . . . . . . . . . . . . 5.16 Safety Electric Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.16.1 Checks and Tests on the Safety Electric Circuits . . . . . . . . . . . . . . . . . . 5.17 Signalling and Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.17.1 Checks and Tests on the Signalling or Control Units Affecting Safety . . 5.18 Electric Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.18.1 Checks and Tests on the Electric Cabinet . . . . . . . . . . . . . . . . . . . . . . .

.............. .............. .............. the Rescue System .............. .............. .............. .............. .............. .............. .............. .............. .............. .............. .............. .............. .............. .............. ..............

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . .

44 44 44 44 44 45 45 45 45 45 45 45 45 45 45 45 45 46 46

v0.00, JULY 01

Page 3 / 46

MSCM02UK

Lift SCM 02

Chapter 1 PASSENGERS RESCUE 1.1 Procedure for a Passengers Rescue Operation in a SCM Lift. 1. 2. 3. Contact the lift technician. SAFETY DEVICES should always remain ACTIVE. TURN OFF THE MAIN SWITCH OF THE LIFT in the upper compartment of the electric cabinet, next to the lift door at the upper floor. CHECK TO SEE THE POSITION OF THE CAR. TRY TO CALM TRAPPED PASSENGERS DOWN and inform them that the rescue operation is going to take place and the car will move. Tell them no to try to open the doors or leave the car until they are told to do so safely. CHECK THAT ALL LANDING DOORS ARE CLOSED AND BLOCKED AND CAR DOORS ARE CLOSED. Put up an OUT OF ORDER sign at each entrance. SELECT THE MACHINE PULLEY TURNING DIRECTION (UPWARDS OR DOWNWARDS AS SUITABLE, TO RUN THE CAR TO THE NEAREST LEVEL ) with the left handle of the upper compartment.

4.

5.

6.

RUN THE CENTRAL LEVER, which operates on the machine pinion, while executing a slight swaying movement with the lever, until it does fully go down, which means that the rescue device is perfectly connected. Then, secure the lever with a through bolt.

7.

LOOSEN THE MACHINE BRAKE, by pulling the lever VERY SLOWLY and move it to turn the pulley manually. WARNING : AT THE END OF EACH CYCLE, LOOSEN THE BRAKE HANDLE. The car may go up or down by itself; in the event of car overspeed (continuous noise and vibration in the rescue lever) loosen the brake immediately. If the car is blocked by the safety gear operation, or if it does not move, contact a qualified technician.

8.

LOOSEN THE BRAKE ONCE THE POSITION IS REACHED. THE CAR SHOULD REMAIN WITHIN THE INTERLOCK AREA; the level LED, installed on the check-up control station of the upper compartment, lights up when the car is at floor level. OPEN LANDING DOORS WITH THE EMERGENCY KEY to free the passengers. Follow the instructions of the emergency key. WARNING : If the car is not exactly at floor level, pay special attention to protect the passengers when leaving the car.

9.

10. ONCE THE PASSENGERS ARE OUT, MAKE SURE THAT ALL DOORS ARE CLOSED AND CORRECTLY BLOCKED. 11. LEAVE ALL DEVICES AND RESCUE SYSTEM OPERATIONS IN THEIR INITIAL POSITION. 12. WARN THE TECHNICAL DEPARTMENT so that the lift is checked before it is restarted.

WARNING : The lift should not have power supply until the assistance of the technical department.

v0.00, JULY 01

Page 4 / 46

MSCM02UK

Lift SCM 02

1.2 Procedure for opening landing doors with the emergency key. In the event of an emergency, the landing door release key should be used to have access to the lift shaft or car. For safety reasons, only trained staff familiar with the rescue procedure are authorised to use this key. WARNING : Should it be necessary to open the landing door to determine the position of the car or to free the passengers, be particularly careful to avoid falls into the lift shaft. Do not leave landing doors open unless the entrance is properly protected and safe, thus avoiding falls into the lift shaft. 1. 2. 3. LOCATE AND PREPARE THE DOOR RELEASE KEY. TURN OFF THE MAIN LIFT SWITCHES IN THE CONTROL UNIT CABINET. LOCATE THE DOOR RELEASE TRIANGLE AT THE DOOR FRAME. All doors have a door release triangle. In the case of MACPUARSA doors, it is located at the door lintel. INSERT THE KEY INTO THE TRIANGLE, TO ENGAGE THE DEVICE. TURN THE KEY IN THE APPROPRIATE DIRECTION TO RELEASE THE DOOR. SIMULTANEOUSLY, OPEN THE DOOR BY PRESSING THE DOOR EDGE MANUALLY. ONCE THE LANDING DOOR IS OPEN, THE CAR DOOR IS NO LONGER BLOCKED AND CAN BE OPENED MANUALLY WITHOUT USING THE KEY.

4.

5. 6.

DOOR

Emergency Door Release Key Emergency Door Release Operation

View of The Emergency Door Release Triangle

v0.00, JULY 01

Page 5 / 46

MSCM02UK

Lift SCM 02

Chapter 2 INSTALLATION AND ASSEMBLY EVERYTHING DETAILED HERE IN THE MATTER OF SAFETY IS EXPLAINED IN GENERAL TERMS. TOGETHER WITH THIS DOSSIER ALWAYS HAVE A DOSSIER FOR THE PREVENTION OF LABOUR RISKS WITH YOU, SINCE ALL SAFETY MEASURES ARE MORE WIDELY DETAILED. 2.1 The Works

Obligatory Head Protection

Obligatory Feet Protection

Always use a safety helmet within the area where the works are taking place, since it will protect you against a possible fall of objects. Also use boots with the soles protected against cutting objects and the upper area of the toes protected with metal reinforcement against knocks and crushing due to the fall of materials of a high weight. The lift shaft should always be clean and free from obstacles, with its accesses being protected against the fall of objects and people, and should be built according to the plan specifications. Ensure that the lift shaft has the necessary hooks in the clear overhead for the loads assembly and elevation, which must have been previously installed by the builder. Check that power supply is three-phase and single-phase. There should be an area to store the materials, which should be as near the shaft as possible.

2.2 Materials Unloading When unloading materials, use the elevation devices available in the works (wheelbarrows, cranes, hand carriages, etc ... ) for weights higher than 25kg. Before making great efforts, use neoprene lumbar belts which will avoid injuries to your back.

Materials will be unloaded in the works by one or several operators of the company in charge of the installation, with the help of the works staff, who will provide the appropriate means to facilitate the tasks of unloading and distributing the material. The fall. following must be taken into account when distributing and storing materials: Materials should be near the lift shaft. They should be located in a place into which water or rubbish may not fall, and far from machines generating dust. They should not be located in a place for passing through and their storage should not entail any danger for people in the event of The person receiving the material will buy it, together with a dispatch sheet, in order to check the most important elements, such as: Car and counterweight frame dbg. Machine and bedframe. Door number, type and hand. Number and type of car and counterweight guides. Number and diameter of traction ropes and overspeed governor. Number of rope hitches. Number and type of car and counterweight guiding. Guides will be supported on three points to avoid buckling. If it is necessary to place them on a finished floor, some material should be put under them (paper, plastic, etc ...), so that the floor does not get dirty with the guide grease. When introducing the guides into the lift shaft, the lower part should be supported on the front side of the pit, and the upper part on the rear corners of the shaft. Leave doors in a safe place, where there is no risk of fall or deformation. If possible, place them at the different floors using a crane. Traction or hydraulic lift equipment should be unloaded together with the bedframe at the upper floor of the installation. In the case that some material had to be left in the open air, something which you should absolutely avoid, make sure that you cover it with plastics in such a way that it does not get dry. Do not leave it supported directly on the floor; it should be placed on pallets, bricks, planks, etc. Check the plastics the material was protected with when manufactured. Never leave the car in the open air, since it could be seriously damaged by water and moisture.

v0.00, JULY 01

Page 6 / 46

MSCM02UK

Lift SCM 02

2.3 Life Rope

The first operation you should perform inside the shaft is installing the life rope, prepared to bear the weight of two persons, and hooks at each of the shaft accesses. It is also important to use safety belts.

Obligatory individual protection against falls

2.4 Shaft Ranging and Check-Up

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

CAUTION
Protect yourself against the fall of objects through the shaft and falls in the vacuum Be careful when drilling, welding, cutting and tightening To go down to the pit use a ladder Use the tools created to that purpose, placing them in the shaft, according to the installation plan; once the cords are suspended proceed to the check-up of each of their axis, floor by floor, to ensure the minimum dimensions indicated in the plan. See sketch. Select the tools for the upper and lower part in the clear overhead and pit respectively. Using the plugs supplied, secure the open pipe 1250 mm in length at a distance of 100 mm lower than distance X which is shown in the bob plumb scheme and ranging plan, trying to prevent the last guide support from interfering in the case of distance X. Fix the squares inside the torn pipe as shown in the sketch, in such a way that the bob plumbs remain in the exact position indicated in the scheme. Then, check these minimum measurements floor by floor. Once ensured, fix the side cords to the lower part, thus turning the intermediary crosspiece, as shown in the sketch. With the central bob plumb, using some colouring, mark a vertical line at the wall in the points corresponding to each guide support. This mark should later coincide with the medium point of each support. Once this operation is performed, the bob plumb can be removed. Two portable scaffolds are supplied to facilitate the ranging and subsequent assembly of supports at each landing door. They have an angular part supported on the corner of the shaft with the floor level, and a tensile part faced to the wall. Scaffolds are light and manageable; in the following pages some pictures show how to use them and how they should be adjusted.

v0.00, JULY 01

Page 7 / 46

MSCM02UK

Lift SCM 02

Ranging; Upper part, clear overhead

Ranging; Lower part, Pit

Scaffolds supplied

Tools for Ranging

v0.00, JULY 01

Page 8 / 46

MSCM02UK

Lift SCM 02

Plumbing Cord

Plumbing Cord with Colouring

Plumbing Cord

Distance Y = 151
300

149

v0.00, JULY 01

Page 9 / 46

Distance X

MSCM02UK

Lift SCM 02

Usage of mobile scaffolds and their packing together with the guide scantlings

IMPORTANT
Maximum load per scaffold : 150 kg When working in the scaffold and near the shaft, the use of the life rope is obligatory

The bottom of the scaffolds is adjustable by 50 mm each time. If they cannot be adjusted at the exact distance of the shaft bottom, fix the bottom of the scaffold slightly above the shaft bottom.

v0.00, JULY 01

Page 10 / 46

MSCM02UK

Lift SCM 02

2.5 Shaft Supports Assembly

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

Having used a bob plumb with some colouring, according to the distance of the ranging bob plumb scheme, make the coloured mark of the wall coincide with the slot in the medium point of the support.

Marking the wall with the colouring of the central bob plumb

1 : Mark 2 : Support

The height for each support is shown in the installation elevation plan

The medium point of the support should coincide with the colouring mark

IMPORTANT
In order to secure each support, use the horizontal tear first. Once it is pre-fixed in that position, check the correct level of the piece, and finally, fix it with the vertical drill of the end. Then assemble the support arms, without tightening them.

2 1

v0.00, JULY 01

Page 11 / 46

MSCM02UK

Lift SCM 02

2.6 Guides Assembly

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

For the guides assembly, place the guides start-up base according to the shaft dimensions and then proceed with the simultaneous commissioning of car and counterweight guides, being the supplied scantlings of great use.

Assembled guides start-up base NOTES In order to introduce the guides into the shaft, use a spring governor, which should be introduced in one of the upper holes of the guide coupling. Distances depending on finished floor.

IMPORTANT Before the assembly, cut the section remaining in the counterweight guides (the male side), according to the distances in the elevation plan, see scheme

In counterweight guides, all female parts should be installed upwards. In car guides, downwards.

v0.00, JULY 01

Page 12 / 46

MSCM02UK

Lift SCM 02

Clean the guides provisionally using a degreasing liquid to remove wax from the sliding part.

Guides Scantling

A : Start-Up Base B : Car Guides C : Counterweight Guides

A : Fixture to Counterweight Guide B : Bob plumb Register C : Fixture to Car Guide

Installation of the 1st section of guides with 2 scantlings.

v0.00, JULY 01

Page 13 / 46

MSCM02UK

Lift SCM 02

Two guide scantlings are supplied. They should be installed approximately 0.5 metres above and below the end of the guide sections, fixing them to the guides. Once they are fixed, make the register of each scantling coincide with the bob plumbs, (thus leaving 1-mm space between the cord and the angular register).

1 mm

1 mm

Once the position of the car and counterweight guides is defined, fix them to the shaft support, and then proceed with the installation of the next section. Notes Do not secure the start-up base to the floor until the position of the guides is not determined in relation to the bob plumbs; car guides should be fixed with through bolts, and counterweight guides, with flanges. The base should be placed centred in relation to the guides. In order to go up floor by floor, carrying out the same operations for each guide section, use the 2 portable scaffolds supplied. In the event that a counterweight guides coupling coincides with the fixing support to the shaft support, the latter should be installed below. The guide tooling should be perfectly levelled in both planes. Guides should be correctly aligned in the coupling. Finally, check all the guide couplings and in the case there were any ribs, remove them using a file.

v0.00, JULY 01

Page 14 / 46

MSCM02UK

Lift SCM 02

Car and counterweight guides fixture to shaft support

General view of the guides and shaft supports

v0.00, JULY 01

Page 15 / 46

MSCM02UK

Lift SCM 02

2.7 Machine Bedframe Assembly

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

A : Counterweight guides

Fixture to car guides

Bedframe wedging

v0.00, JULY 01

Page 16 / 46

MSCM02UK

Lift SCM 02

2.8 Bedframe Assembly Sequence

Main part

Fixture to counterweight guides

Upper arms

Joining arms to the main part

Fixture to car guides through flanges

Lower support for the interlock

Joint to main part

Flanges to car guides

General view of the bedframe and its components. In the lower part there are supports for the frame interlock inside the pit, to be assembled on the first guide support.

v0.00, JULY 01

Page 17 / 46

MSCM02UK

Lift SCM 02

2.9 Placing the Machine On the Bedframe

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

Perform as explained in the first paragraph of section 2.2. Using the elevation system installed on the upper part of the shaft, lift up the machine to its final position on the bedframe.

View of the machine on the bedframe A : Rope holding system

Lighting inside the clear overhead

Load elevation system

v0.00, JULY 01

Page 18 / 46

MSCM02UK

Lift SCM 02

2.10 Securing the Electric Cabinet

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

Secure the electric cabinet using the supports supplied for that purpose, taking account of the fact that a provisional assembly should be carried out as a previous step to place the revision hose. WARNING : Under no circumstances should the cabinet be installed inside an enclosure or a private place. Firstly, fix the brackets in relation to the floor level, in order to install the panel and fix it according to the scheme. See the installation dossier supplied together with the preassembled electrical installation.

v0.00, JULY 01

Page 19 / 46

MSCM02UK

Lift SCM 02

2.11 Carrying Out the Electrical Installation of the Machine Disconnect the main switches of the installation. Use tools with an insulator not less than 1000V against possible electrical discharges. The working uniform should not be made of fabric with plastic components (cotton recommended).

See the installation dossier supplied together with the preassembled electrical installation and the installation dossier for the Machine Sassi Leo (Model with Disc Brake). 2.12 Executing the Connection of the Revision Hose

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

See the installation dossier supplied together with the preassembled electrical installation.

v0.00, JULY 01

Page 20 / 46

MSCM02UK

Lift SCM 02

2.13 Car and Counterweight Frame Assembly (wedge boxes should be assembled) Before carrying out this task, follow the steps in section 4 and perform as explained in the first paragraph of section 2.2.

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

To assemble the frames, take account of the distances and dimensions in the plan for their correct location in the shaft.

A : Counterweight frame B : Car frame

Once they are pre-fixed to the plan dimensions, proceed with the installation of the ropes. See the assembly dossier for car and counterweight frames and wedge boxes (safety gear).

Car mechanical interlock system assembly

v0.00, JULY 01

Page 21 / 46

MSCM02UK

Lift SCM 02

2.14 Traction Ropes Assembly Before carrying out this task perform as explained in section 4 and the first paragraph of section 2.2.

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

Try to unroll them one by one and in the same direction that they were coiled, in order to avoid loops in them, holding the rope roll and unroll it little by little. The following drawings show how to attach the ropes to the rope sockets. This is how to attach the ropes to the car frame as well as to the counterweight frame. The first drawing shows in detail how to pass the rope through the rope socket.

No 1 2

Part Name Rope Socket Rope

Qty -

v0.00, JULY 01

Page 22 / 46

MSCM02UK

Lift SCM 02

The next drawing shows in detail how the rope clamps are attached. Place two rope clamp clevis for each one of them. Once the rope is attached, it is a good idea to affix the end of the rope to the rope itself (for example, with insulating tape). Short rope clamps with springs should be installed on the counterweight and long rope clamps without springs, on the car frame.

Rope hitch in counterweight

v0.00, JULY 01

Page 23 / 46

MSCM02UK

Lift SCM 02

2.15 Machine Pulley Covers Kit Assembly

Obligatory hands protection

Obligatory face protection

2.16 Instructions for Weights in the Counterweight Frame Before carrying out this task, perform as explained in the section Shaft Ranging and Check-Up.

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

Before placing the lift in hitch, introduce the necessary weights to counterweight the car frame, as detailed in the plan. 2.17 Assembly of the Speed Governor and its Rope in the Car

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

IMPORTANT : Before placing the lift in hitch, introduce the necessary weights to counterweight the car frame, as detailed in the plan. See the installation and assembly dossier for the speed governor.

v0.00, JULY 01

Page 24 / 46

MSCM02UK

Lift SCM 02

2.18 Car and Counterweight Buffer Support Pillars Assembly Before commissioning a lift under revision ensure that there are no obstacles inside the shaft, and check that all accesses to the shaft are duly protected, thus preventing people not responsible for the installation from leaning over. Also make sure that people travelling in the assembly platform are not using the life rope during the travel.

A : Counterweight screen B : Counterweight buffer support pillar C : Counterweight buffer

v0.00, JULY 01

Page 25 / 46

MSCM02UK

Lift SCM 02

2.19 Doors Assembly

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

The car floor assembly should be carried out according to the installation of the car frame, as explained in the safety gear installation dossier, the car assembly dossier and the dimensions detailed in the assembly plan. Once the car floor is assembled, proceed with the installation of the landing doors. Use the appropriate tools. Check that the corresponding lock blocks the door once it is installed. Perform as explained in the section Shaft Ranging and Check-Up and the first paragraph of section 2.2, (see landing doors assembly and installation dossier). 2.20 Car Assembly

Obligatory head protection

Obligatory feet protection

Obligatory individual protection against falls

Obligatory face protection

Obligatory hands protection

Before carrying out this task, perform as explained in section Shaft Ranging and Check-Up and the first paragraph of section 2. Likewise, do not forget to check the weight in the counterweight frame again. The rest of the car should be installed, taking account of the corresponding spaces in relation to the landing doors.

IMPORTANT : Before working from the car roof, and as a step for the car assembly, you should install the protection handrail.

v0.00, JULY 01

Page 26 / 46

MSCM02UK

Lift SCM 02

2.21 Doors Operator Assembly in the Car (see the installation dossier of the reveco operator).

Obligatory face protection

Obligatory head protection

Obligatory hands protection

In the assembly of the different components and accessories of the electrical part, perform as explained in section Shaft Ranging and Check-Up and section machine electric installation. 2.22 Tools The following tools are absolutely necessary to carry out the assembly of the different lift components: An electric or thermal hoist with a minimum load of 200 Kg. A gauge for car and counterweight guides. Control station with a plug. A control unit hose. A wire or nylon reel o with their corresponding plumbs. Tool box or boxes. A 300 gr bob plumb. Two 1500 gr bob plumbs. Two tensile aluminium scaffolds. A tracer bob plumb (drawing pen). A metal graduated bracket. A level. A mallet. A flat chisel. A 2 m metre. A hammer drill. A small normal drill. A drill chuck with an adaptor for iron bits. A wheel. A welding machine. Revolving cutters. Two adjustable spanners (a big one and a small one). A high security key set, 6-7 to 27-29. An Allen key case, 2-12. A reversible ratchet-spanner. Box spanners for squaring. A pair of universal pliers. A pair of round-nosed pliers. A pair of curved-nosed pliers for external washers. A pair of electrical scissors. A small straight-nosed screwdriver. Un medium straight-nosed screwdriver. Un big straight-nosed screwdriver. A star screwdriver. A stecker screwdriver. A fixed saw bow. Two steel handsaw blades. A rat-tile file. A flat file. Four pairs of tongs for quick adjustment. A pressure jaw. A multimeter or voltage tester. A conical smoother. Two brushes (a big one and a small one) Bits for widia concrete. Diameters, 6,8,10,12,18. A long through bore bit; diameter, 12 x 165. Bits for metals; diameter, 2.25,3,5,7,9,11,13.

v0.00, JULY 01

Page 27 / 46

MSCM02UK

Lift SCM 02

A protected portable computer. An oilcan. Adjustable G Clamp. A wound extension piece with different sockets. A thickness gauge set.

This is the basic material. People responsible for the assembly of the different lift components can use as many more tools as they deem necessary, and get the necessary material for the correct execution of their work. To avoid losing time, use plugs, insulating tape, screws, terminals, strips, rivets etc ..., which may be necessary at any time during the assembly operations.

v0.00, JULY 01

Page 28 / 46

MSCM02UK

Lift SCM 02

Chapter 3 COMMISSIONING

IMPORTANT
Before a lift is commissioned, check the existence and correct installation of : Car and landing doors. Final limit switches and terminal stopping switches. Ropes and rope hitches. Counterweight protection screen. Machine-bedframe set (check that nuts and screws are correctly tightened). Electric wiring in the car, control unit cabinet and shaft (in duplex configuration, please consult the sequence of operations to connect both lifts in the dossiers concerning the electrical section). 3.1 Checks and Tests a) Locking Devices. First of all, make sure that landing doors are aligned with the car doors. They should not rub against each other or against the door frame. Check to see if interlock rollers and lock rollers are adjusted. Check the door interlock to make sure that once the landing door is closed the car moves. Try to move the door sideways when it is closed; there should be no movement at all. The car will not be able to move until the locking elements are engaged as shown in the diagrams below:

Effective interlock in closed position and safety electric contact established


(*)

Minimum height 9mm.

Interlock Cam Slide Closing Zone


4

MAX. 2

Rear view of the mechanical interlock cam slide

v0.00, JULY 01

Page 29 / 46

(*) 9

MSCM02UK

Lift SCM 02

b) Safety Electric Devices (Appendix A / Regulations). ELECTRIC SAFETY MEASURES. Ensure that there are no loose contacts and that all the connections are secured; observe the following: Differentials : These must have an appropriate triggering sensitivity (300 mA. Max for power and 30 mA. for lighting) and should have at least the same current as the magnetothermic. They should be disconnected manually and should be tested. Magnetothermics : They should have a maximum of twice the power as the elements they protect under normal working conditions. Ideally the current input should go to the magnetothermic, which should always be in the front and then to the differential. Finally, it should go to the installation. Theses checks should be carried out in the power and lighting circuit. 2. CONTROL PANEL. Check that the phase and inversion failure relay is present and works when necessary. Check all wire connections, both input and output, and especially heavy current connections, making sure that they are properly tightened and correctly adjusted. There should not be any wires outside the connection terminal. Ensure that all the contacts are properly adjusted, especially those which correspond to the contactor auxiliary contact blocks; check that they are properly adjusted in their housing. If necessary, disassemble the relay capsule or contact blocks to adjust them or blow to remove any possible dust. The thermal relay test should be performed with the motor at its normal working temperature, after having made several trips. Remove a phase from the motor or block (disconnect) the brake so it does not open. The time required to disconnect the control unit should not be more than 10 seconds or less than 8. Check that the earth connection is well connected in the control panel and that the door (if any) is earthed. CAR, OUTSIDE, AND MAXIMUM TRAVEL TIME TIMERS. Ensure that the car control station commands are given preference over the outside control stations for at least two seconds. If not, adjust the car and outside timers in such a way that the waiting times are not very long. For example: car timer, 2 seconds; outside timers, 4 to 5 seconds. The maximum travel time timer should be adjusted so that the maximum travel time is longer than what it takes the car to travel the distance of two consecutive floors, always in the least favourable case. In the case of two-speed lifts, at slow speed, the maximum travel time should be 5 seconds above this time. This timer also controls the stopping of the operation if the ropes begin slipping on the sheave. GOVERNOR ELECTRIC CONTACT. Check that when the governor contact is tripped, the operation stops. Also check the tension pulley electric contact. This contact should stop the operation if a rope is stretched. CAR SAFETY GEAR. Verify that the safety gear contact stops the operation. REVISION OF THE CONTROL STATION OPERATION. Ensure that pushbuttons work in the correct direction. Check that the revision switch shuts down the lift operation as well as the car and outside control stations. Check that the lift stops when the stop button is pressed. FINAL LIMIT SWITCHES. Ensure that the operation is stopped when the lift overshoots the top- and bottom- stops before the car or counterweight makes contact with the buffers. SAFETY MEASURES IN THE CAR ROOF. Make sure that the slack rope switch, the STOP button and any other safety devices installed on the car roof cut off the power to the control unit and stop the lift when actuated. CAR DOOR CLOSING SAFETY CONTACTS. Make sure that the door contacts function properly, that the male and female parts fit together well and that the connection wires are well tightened. 1.

3.

4.

5.

6.

7.

8.

9.

10. PIT ELECTRICAL OUTLET AND STOPPING DEVICE. Check that there is a socket outlet base with an earth connection and a device for stopping the lift operation. 11.- EMERGENCY LIGHTING. Ensure that the lighting is sufficient with power on and off. The emergency lighting should be able to function for an hour.

v0.00, JULY 01

Page 30 / 46

MSCM02UK

Lift SCM 02

12. CHECK STOPPING PRECISION AND SMOOTHNESS. Ensure that for one-speed lifts, with half a load, the lift stops with no more than a 3-cm difference at the floor level of the car and landing, both going up and down. For two-speed lifts, this difference should be no more than 1 cm. Check that for two-speed lifts, the gears shift smoothly and the car moves slowly for at least the last 10 cm before stopping. 13. CALL BUTTONS (Landing and Car Pushbuttons). Check that they cause the lift to work and the numbering corresponds to the floors. Check that the different light indicators (occupied, door open, etc.) work properly. 14. LOAD WEIGHING DEVICE AND INDICATOR SIGN, CHECK OPERATION. Make sure that the leds of the indicator sign work and that the lift does not move if the car load exceeds the rated load. In that case, all the leds light up in the load indicator, and the inside overload warning buzzer sounds. 15. POSITION INDICATOR. Check that it works. The number on the position indicator should correspond to the floor the car is on. 16. PHOTOELECTRIC CELL. Ensure that it works in automatic landing doors and car doors, and that it causes them to reopen when there is an obstacle. 17. DOOR OPENING PUSHBUTTON. Press and check that the doors are reopened, except when this command is cancelled. In any case, this should always take place within 5 cm before closing. 18. CAR DOORS. Make sure the doors completely close off the entrance opening and there are no gaps greater than 3.5 mm. The doors should not make any noise when closing or opening and the lift should not start moving if there is an object greater than 1.5 cm in width stuck between the doors. The doors should not rub against each other, and should make no noise under operation. 19. EARTH CONNECTION. Ensure that all doors are connected to the lifts earth through terminal. c ) Suspension elements and their attachments. Check that the rope diameter (use a gauge) and form are appropriate as per Document no. 5, Complete List of Lift Components and Document no. 8 Basic Rope Features. Ensure that the terminal and socket rope hitches, nuts, locknuts and safety pins, both in car and counterweight (electric lifts) are in perfect condition. d ) Braking system. Check the correct operation of the brake. For that purpose, the car should be loaded with 25% over the rated load. The test should be carried out with the car descending at rated speed by cutting off the power supply to the motor and brake. The brake should be able to stop the lift by itself. e ) Power or current measurement and speed measurement. In order to check the lift speed, load the car with half the rated load and using a tachometer, make sure that the working speed corresponds to that described in the plans. Use an ammeter clip to check the current at start-up and under operation and make sure they are correct according to the motor features. This measurement should be taken in the three phases.

v0.00, JULY 01

Page 31 / 46

MSCM02UK

Lift SCM 02

f)

Electrical installation.

1. Measurement of the insulation resistance for the different circuits. Using an ohmmeter, check that they exceed the insulation resistance values. Nominal Voltage of the Circuit (V) SEL 500 > 500 Test Voltage (DC) V 250 500 1000 Insulation Resistance (M5) 0.25 0.5 1

The insulation resistance should be measured between each live conductor and earth. The electronic components should be disconnected to carry out these measurements 2. Also check the continuity (the union of the earth terminals to each other) between the machine room earth terminals and that of the motor, control station, guides, governors, tension pulley and car and any other element that is subject to accidental drop in voltage.

g ) Final limit switches. Check that the final limit switches stop the lift operation when the lift goes past the end stops. h ) Checking adherence and verification of balance between the car and counterweight. Adherence : Check visually that there is no slippage between ropes and pulley under normal operation. Counterweight balance : Load the car with half the maximum load allowed and take it to the middle of the travel, so that the counterweight is more or less at the same distance from the machine room. Apply the brake by hand and slowly move the flywheel. If the lift tends to ascend or descend there is either too much or too little weight in the counterweight. It is advisable to load the counterweight with slightly less weight than required rather than perfect equilibrium or too much weight. 3.2 Car and Counterweight Adherence : Check visually that there is no slippage between ropes and pulley under normal operation: Using a piece of chalk mark the pulley and ropes at the same point and check there is no difference in their position, after the car has run up and down with 100% of the rated load. Perform this operation again with the car empty. Counterweight balance : In order to carry out this test, all car decoration should be finished. Load the car with half the maximum load allowed and take it to the middle of the travel, so that the counterweight is more or less at the same distance from the machine room. Apply the brake by hand and slowly move the flywheel. If the lift tends to ascend or descend there is either too much or too little weight in the counterweight. It is advisable to load the counterweight with slightly less weight than required rather than perfect equilibrium or too much weight (that is to say, it is better if the car tends to go down). i) OVERSPEED GOVERNOR. 1. Use a tachometer to check the governor triggering speed; ensure that the speed corresponds to that indicated on the overspeed governor. For that purpose, the governor should not have a rope attached. The operation must be carried out directly on the governor. 2. When the governor contact is tripped, operation should be interrupted. CAR SAFETY GEAR. Check the correct installation and adjustment of the safety gears. Ensure that neither the rollers nor the wedges rub against the guide rails. There should be enough space between the guides and the car to allow the lift to operate correctly. 1. Test in descent: Load the car with 125% of the rated load, evenly distributed over the car area, and lock the overspeed governor pressing the pushbutton in the control unit cabinet; the lift should run at checking speed. Ensure the car remains in front of a landing door, so as to unload it, thus unblocking the safety gear. 2. Test in ascent: This test is carried out in the same way, but with the car empty and the lift moving at rated speed. After performing this test make sure that no deterioration has been caused that might affect the normal use of the lift. Replace braking components (wedges, rollers), if necessary. Visual check is considered to be sufficient.

j)

v0.00, JULY 01

Page 32 / 46

MSCM02UK

Lift SCM 02

k)

BUFFERS. Energy storage type buffers (springs). For this test, the car with its rated load should be placed on the buffers and the ropes should be made slack. Check the compression corresponds to that given by the characteristic curve of the buffers. Do not exceed the distances indicated in Document no. 15 Installation Plans. INTERCOM. Check the correct operation of the bidirectional communication device. MECHANICAL CAR LOCKING DEVICE. Make sure that the latch fits in its housings, that it moves correctly in both directions and that the control unit is disabled when frame and car are locked. Load the car roof with 150 kg and check the system resists without any appreciable damage. (Warning: the car must remain empty). MECHANICAL RESCUE SYSTEM. Perform a simulated rescue operation, both in ascent and descent. After performing these operations, check that the towrope stretching is still correct and that the pinion engaging the machine shaft remains in its initial position.

l)

m)

n)

v0.00, JULY 01

Page 33 / 46

MSCM02UK

Lift SCM 02

Chapter 4 USE OF THE LIFT SCM 4.1 Purpose of These Instructions This chapter includes the necessary instructions for the normal use of the lift SCM, in accordance with standard EN 81-1 and Royal Decree 1314/97 Appendix I, 6.2. This dossier provides the necessary information for the normal use of this lift by the user, placing great emphasis on certain points which, due either to difficulty or necessity, will enable the correct use of it. 4.2 The Intended Use of the Lift These lifts are designed to transport passengers in residential and public buildings. They may also be used to transport goods whose weights and dimensions should not exceed the total load of the lift and the dimensions of the car. It is absolutely forbidden to transport goods that might damage the installation or the car itself. There is a sign inside the car indicating the rated load of the lift in kilograms and the maximum number of passengers allowed. The load permitted by the lift should never be exceeded (for that purpose, there is a device in the lift that indicates when overload occurs; in this case, the excess of load should be removed). Likewise, the number of passengers specified should never be exceeded as this could cause an overload. The basic operation of the lift consists in the movement of the car (loaded or empty) from one floor to another. For that purpose, the user should stand in front of the entrance to the lift, where there is an electric control station. Pushbuttons next to the landing doors may have different symbols or abbreviations. Some of the symbols or abbreviations used for this range of lifts are detailed below.

Call Button : calls the lift to go up or down

Up Button : orders the lift to go upwards

Down Button : orders the lift to go downwards

Once the lift has been called, you will observe it has arrived when the doors open (automatic doors), when the inside light of the car can be seen (manual door with vision panel) or when a light or an acoustic signal in the electric landing control station so indicates. Once the doors are open, you can go into the car where there is a control station and a sign specifying the rated load of the lift in kilograms, as well as the maximum number of passengers.

v0.00, JULY 01

Page 34 / 46

MSCM02UK

Lift SCM 02

There is a series of pushbuttons in the control stations, which are detailed below:

Car pushbutton to choose the desired floor level (-2,-1,0,1,2,3, etc ...)

Alarm button to ring the alarm (yellow).

Door Open button to re-open the door(s).

Door Closed button to close the door(s).

Intercom button for external communication.

Overload indicator.

There are also displays which indicate the floor the lift is on, both inside and outside the car (floors).

The user may also find other messages on the control panels and indicators, since they may have been specially requested by the owners.

v0.00, JULY 01

Page 35 / 46

MSCM02UK

Lift SCM 02

4.3 Types of Control Units The lift operates differently depending on the type of control unit : 4.3.1 Simplex Automatic Control Unit As soon as the car doors close, the passenger in the car has three seconds to move the car before the passengers at the floors can call the lift. Control unit operation in ascent: once a button is pressed, the car goes directly to the corresponding floor. If there is more than one passenger, the one who is going to the lowest floor should press his floor first. When the desired floor is reached and the passenger has left the lift, the doors will close and the button should be pushed by the passenger going to the next lowest floor, and so on. Control unit operation in descent: the passengers call the lift to their floors by pushing the call button, as long as the occupied signal is not lit; otherwise, the call will not be registered and the lift will not come. Once the car is at the floor, which can be noticed by looking through the door vision panel or through a light signal indicating the presence of the car, the passenger can open car and landing doors, and during the few seconds of preference that the passenger in the car is given over another passenger at a landing, he can order the movement of the car, as explained before, without any risk of interference. 4.3.2 Simplex Collective Control Unit in Descent Those lifts provided with this control unit have a memory which registers the up and down commands of the passengers in the car. However, this memory only registers the down commands of the passengers who are waiting at the floors, not their up commands. Control unit operation in ascent: pushbuttons in the car are also given a three-second preference over those at the landings, from the moment when the lift is about to move (doors closed). In lifts with automatic doors with a photoelectric sensor at the door threshold, they are also given preference whenever a passenger enters the car. As the passengers enter the car, they press the buttons corresponding to the floors they want to go to. Once the last passenger is in, that car begins moving automatically, and it stops at the floors requested. When the last passenger has left the car at each floor, the doors close and the lift starts to move again. In ascent, it does not answer any call from the landings, except for the one from the highest floor, provided that it is above the highest one requested by the passengers going up inside the car. When the car reaches this floor, passengers get in and, as detailed before, once the doors are closed they are given a three-second preference over the landing calls, to choose the direction of the travel. If someone presses a button to go further up, the lift will go up even though it has previously registered calls to go down. Control unit operation in descent : passengers will give the down command and the lift will automatically descend and stop at those floors from which the command was given. 4.3.3 Simplex Collective Control Unit in Ascent and Descent With the simplex collective control unit in ascent and descent, the car does not only stop and pick up passengers from the different landings on its way down, just like the previous control unit, but also on its way up. Control unit operation in ascent : as the passengers enter the car and press the buttons that correspond to the floors desired, these commands are registered in the memory of the lift. Once the last person has gone in and the doors have closed, the lift begins to move. It stops successively at those floors requested by the passengers inside the car as well as those floors where passengers at the landing have pressed the up button. It will not respond to the calls from landings to go down, even though it does register them in its memory. The lift will respond, however, to the down button of the highest floor above the last floor it has been ordered to go up to. Control unit operation in descent : the car picks up all passengers from those floors where the down button has been pressed. As the passengers enter, they press the button for the floor they want to go to, which is registered in the memory. As it descends to the ground floor, the car stops at all those landings requested by the passengers of the car and landings. 4.3.4 Duplex Control Unit Duplex control unit consists in a single control unit for two lifts. There is only one landing control station at each floor and only one car can be called. The nearest car will always come. The operation of the car control station is exactly equal to that of lifts with simplex automatic control unit. Passengers must order their calls, pushing the button for the lowest floor first. Once the car has reached that floor and the passengers have left the lift, the button for the next floor should be pressed, and so on. The passengers in the car should press the buttons corresponding to the floors they want to go to from the lowest to the highest one.

v0.00, JULY 01

Page 36 / 46

MSCM02UK

Lift SCM 02

The passengers at the landings should wait until the red occupied sign is no longer lit before calling the lift. The free car will then go to that floor. If both lifts are free, the nearest car will go to the floor from which the call was given. If only one lift is free, once the button has been pressed, it will light up to indicate that the call has been registered and the red occupied sign will also light up. If both cars are free, the white call button will light up, but not the occupied sign, since one of the lifts is free. 4.3.5 Duplex Collective Control Unit in Descent It is a combination of duplex control unit and simplex collective control unit in descent. It operates in the same way as the collective control unit in descent with regard to the control stations and signals and the way the commands are carried out for the passenger in the car. The difference is that there is a single landing control station at each floor for both lifts. Control unit operation in ascent: as the passengers enter the car they press the buttons that correspond to the desired floors and these commands are registered in the memory of the control unit. Once the last passenger is in and the doors are closed, the car automatically begins to move and it stops successively at the floors requested, starting to move again once the passengers have left and the doors have closed. On its way up, it does not respond to any call to go down from the passengers at the floors, except for those from the highest floor, provided that this floor is above the highest floor requested by the passengers in the car. When the passengers at the highest floor have entered the car, they have three seconds to press a button and choose the direction of the travel. If they press a button to go upwards, the car will ascend, even though calls to go down were previously registered. Control unit operation in descent: if passengers press a button to go down, the lift will descend, stopping automatically at all floors from which the calls were registered (provided that they are lower floors) as well as the floors requested by the passengers in the car. Once the lift has reached the lowest floor requested, it will not respond to calls from lower floors. 4.3.6 Duplex Selective Control Unit in Ascent and Descent It is a combination of duplex control unit and collective control unit in ascent and descent. Control unit operation in ascent: as the passengers enter the car, they press the buttons which correspond to the floors they want to go to. Once the doors are closed, the car automatically begins to move and it stops at all floors requested by the passengers inside the car and at those floors where passengers at the landings have pressed the up button. It will not stop at those floors where passengers at the landings have pressed the down button, although this will be registered in the memory of the lift for the moment when the lift goes back down. The lift will, however, respond to the down button at the highest floor above the last floor requested by the passengers inside the car. Control unit operation in descent: once the lift has responded to all the up commands, the car goes to the highest floor registered by a passenger from a landing to go down. Once the passengers have entered the car and their calls have been registered, it begins to go down. It stops at all floors where the down button has been pressed. It does not respond to the up commands, except for those from the lowest floor requested, provided that this floor is below the last one registered to go down. Anyhow, the distribution of calls and ascents between both lifts takes place according to a program, which depends on its intended use within the building. Now that we have seen how the different control units work, there are certain points to keep in mind regarding the use of the lift: Once the lift has finished the travel (either upwards or downwards) the lift will stop at the floor requested (in order to know the floor the lift is at, you only need to look at the number indicated on the display or listen to the floor announcement device). Wait until the doors have opened and exit the car. When the landing door is manual, the user will have to push it open. The lifts have an overload control device. This device will be activated when the load of passengers exceeds 110% of the authorized load. A light will come on and an acoustic signal will sound in the car to indicate an excess of load. When this happens, the lift will not start up again until a sufficient number of passengers get out of the car to lessen the load below the overload level. Passengers should enter and exit the lift as quickly and orderly as possible and should avoid stopping in the doorway. If the lift has a re-opening system (photoelectric cell, etc.), be sure not to remain in its path since this will prevent the car doors from closing. Upon entering and exiting, make sure that your clothes or other objects do not get caught in the door. To ensure that this does not happen, do not stand too close to the door. Should an unexpected situation arise (e.g. the lift stops) the passengers should try to remain calm. If the lift stops unexpectedly, press a floor button, and if the lift does not respond, press the alarm button. If there is no alarm button, press the exterior communication button and wait for a response. If a rescue operation is necessary, wait for instructions as to what to do.

v0.00, JULY 01

Page 37 / 46

MSCM02UK

Lift SCM 02

4.4 Information on the Normal Use of the Lift 4.4.1 Keep the Documentation The person using the lift should be familiar with the instructions for using a lift. These instructions should be kept so that they can be consulted at any time. The detailed instructions to be followed in case the lift stops unexpectedly -and, especially, the instructions that correspond to the manual rescue operation or the electrical rescue operation, as well as the landing door release key- should be kept in the machine room or inside the machine room door. 4.4.2 Situations that Require Professional Intervention Whenever it is necessary to perform a passenger rescue operation or use the emergency door key, professional workers should be called in. These operations should only be performed by properly trained staff. 4.4.3 Entering and Exiting Safely When entering or exiting the car, passengers should remember to be careful not to get clothes, bags, packages, etc. caught in the door. Passengers should enter and exit in an orderly fashion and should not stop in the doorway. If the lift has a re-opening system (photoelectric cell, etc.) be sure not to remain in its path since this will prevent the car doors form closing. The dimensions and weight of the load should not exceed those allowed by the lift. The number of passengers should not exceed that indicated on the sign inside the car. 4.4.4 Lift Accesses Free from Obstacles at The Landings Any possible interference within the access to the lift - a stairway or any other object (e.g. plants, wastepaper bins, etc.)- should be avoided. 4.4.5 Open Shafts If the lift is installed in an open or partially-open shaft, special precautions should be taken to prevent objects from falling into the shaft and to keep out anything that might damage the lifts moving parts and interfere with its safe operation. 4.4.6 Control Unit Cabinet / Upper Floor There should always be a sign at the entrance to the control unit cabinet indicating Lift Control Panel - Danger - Authorized personnel Only. This inscription restricts access to the control unit cabinet; only authorized personnel (for maintenance, verification and passengers rescue operation) can go in using a key. During the inspection, maintenance, rescue, start-up operations, etc., make sure that the machine as well as the bedframe and the car roof are correctly lit. 4.4.7 Description of the Different Control Unit Cabinet Components Upper Part Main switches Protection box Emergency device Inspection box Lighting switches

Lower Part Control Panel

For a more detailed description of switches, see chapter on maintenance.

v0.00, JULY 01

Page 38 / 46

MSCM02UK

Lift SCM 02

4.4.8 Use of the Emergency Key As we have said, when a situation requires the intervention of trained personnel, the use of the emergency key is restricted to the trained personnel. The use of the emergency key is described in the rescue operation manual. 4.4.9 Maintenance The owner of the lift, as the person responsible for its use and its safety conditions, should contract a qualified company for the maintenance of the lift. This company should have a book of incidences of the lift, where a record is kept of repairs when important problems or accidents occur or parts are replaced in the lift. This book should be at the disposal of the owner should he request it. When necessary, the owner should request the compulsory inspections and facilitate the access to carry out these checks and tests. If the installation has not been used for a long time, he/she should request the maintenance company to execute a general check-up of the lift. Whenever any user detects a problem in the way the lift operates, the owner should immediately communicate this anomaly to the maintenance company and put up Out of Order signs at all lift doors. When the landing doors are being cleaned, special care should be taken so as not to spill or drop any products (liquid or solid) into the lift shaft.

v0.00, JULY 01

Page 39 / 46

MSCM02UK

Lift SCM 02

Chapter 5 MAINTENANCE

WARNING
THE ACCESS TO THE MACHINERY ( MACHINE, BEDFRAME, SPEED GOVERNOR, etc ... ), TAKES PLACE FROM THE LAST FLOOR DOOR, WHERE THE ELECTRIC CABINET IS LOCATED. BEFORE GETTING ACCESS TO THE CAR ROOF, STOP THE MACHINERY FROM AN APPROPRIATE DISTANCE IN ORDER TO LOCK THE DOOR OPERATOR EASILY. UNDER NO CIRCUMSTANCES SHOULD THE CABINET BE LEFT OPEN WITHOUT SURVEILLANCE. THE CAR ROOF IS DESIGNED TO BEAR THE LOAD OF TWO PEOPLE DURING THE MAINTENANCE OPERATIONS.

5.1 Description of Components Protection panel : FF . . QF . . FA . . QAC QAH QASM TC . . SAH . SAC . . . . . . . . . . . . .. .. .. . . . . . . . . . power differential. power magnetothermic. lighting differential. car lighting magnetothermic. shaft lighting magnetothermic. machine room lighting magnetothermic. earth connection. shaft lighting switch. car lighting switch.
R S T N t
R S T
FANOX

Machine panel : TRM . . . KRL . . . KRNS . . KRREV . KSG . . . KRSE . . KRFR . . SLV . . . SRLV . . BTST . . GRF . . . TS . . . . COND . 3VFMAC K1, K2 . FS . . . . BAT . . . F1 . . . . F2 . . . . F3 . . . . F4 . . . . . . . . . . . . . . . . . . . . . . . . . control unit transformer. level led relay. rated speed relay. revision relay. safety series relay. direction relay. brake relay. speed governor operation pushbutton. speed governor reset pushbutton. temperature probe. brake rectifying plate. thermal probe. condenser. frequency changer. contactors. output filter. level led battery. speed governor operation fuse. speed governor reset fuse. level led fuse. VK2P load weighing device supply fuse.

BTST

211C

212C

211H

212H

LV1

LV2

205

206

204

210

212

U V W t

BAT

v0.00, JULY 01

S T

Page 40 / 46

MSCM02UK

Lift SCM 02

5.2 Lift Shaft The following checks and tests should be carried out during the lift shaft maintenance inspections. In order to communicate with the outside, the maintenance personnel should always have a telephone susceptible of connection to any of the existing telephone coupling boxes when these checks and tests are being carried out inside the shaft. Use a ladder -it hangs at one of the pit walls- to get into the pit. 1. Check that there are no water leaks in the pit or combustible substances that might cause a malfunction of the lift. Ensure that the pit is clean, dry and free from waste. The lift shaft and pit should have enough artificial lighting to perform this inspection properly: check that the system works. Check that the revision pushbutton panel (car roof) woks properly and that the lift does not respond to calls either from the floors or from the inside of the car when the revision control device is on. IMPORTANT : The ladder to get into the pit should be put back into its place, one of the pit side walls, after the maintenance operations.

2. 3.

4.

5.3 Guides The following checks and tests should be carried out during the guides maintenance inspections. 1. 2. Check the condition of the car and counterweight guides and their fixture. Check any possible dbg variation. If the lift has automatic greasers on the car and counterweight, check the oil level, and refill if necessary. If the lift does not have an automatic greaser, it is advisable to grease the guides every two or three months, depending on how much the lift is used. Use the appropriate lubricant for each type of material. Excessive lubrication can be as detrimental as not enough lubrication 5.4 Landing Doors The following checks and tests should be carried out during the lift landing doors maintenance inspections. 1. Check the correct operation of the circuit in all the doors. Should only one of the contacts of the circuit fail, the lift will not work. With automatic doors, in order to check this, cause the malfunction by actuating the lock. Ensure that the mechanical interlock of the door woks properly. To do so, try to slide the door sideways: the door should not move.

2.

v0.00, JULY 01

Page 41 / 46

MSCM02UK

Lift SCM 02

3.

With automatic doors, both in commissioning and in periodic inspections, check that the unlatching parts of the mechanical interlock do not interfere with each other or overlap. Likewise, make sure that the door does not come unlatched due to door panel displacement. Also check that the 9-mm distance is not exceeded, as shown in the diagram.

Interlock in closed position and safety electric contact established

Interlock Cam Slide Closing Zone


4

MAX. 2

Rear view of the mechanical interlock cam slide


(*)

Minimum distance, 9mm. For this distance, only measure the straight surface from the end of the curve.

4.

The following should all be checked during the periodic inspections: the interlock; sensitivity of the door when a passenger is either hit or about to be hit by the closing door; that the lift does not start when the door is open; the wear of the slide shoes; the contacts; the door suspension carriage rollers; etc. If necessary, the different components should be cleaned, adjusted or replaced (see landing doors assembly dossier).

5.5 Ropes The following checks and tests should be carried out during the commissioning and maintenance inspections of the traction ropes and rope hitches. 1. Upon commissioning as well as in periodic inspections, check the condition of the ropes in their entirety. For that purpose, count the broken wires. A broken cord or its equivalent in wires, in a one-metre length of rope, requires that all the ropes be replaced. In order to find fractured threads, pass a cotton rag along the rope. Threads fractured due to wear (abrasion) must be detected visually. Check the condition of the counterweight and car rope hitches; in particular, check that the nuts of the rope hitches are securely fastened. Check the lubrication of the ropes. Make sure that the grease on the rope does not impede its inspection.

2.

3.

v0.00, JULY 01

Page 42 / 46

(*) 9

MSCM02UK

Lift SCM 02

5.5.1 Procedure for Replacing the Ropes a) Lock the car in the lower locking support, and at the same time, hung the counterweight in the upper part of the shaft, without exceeding the maximum load allowed for the hooks located in the clear overhead. Put additional security slings in both frames. In car frames, change the ropes from the pit and in counterweight frames and machine use the assembly scaffolds located on the last floor.

b) c)

5.6 Machine and Bedframe The following checks and tests should be carried out during the commissioning and maintenance inspections of the machine, bedframe and mechanical brake (see Use and Maintenance Dossier of the Machine Sassi Leo). 1. 2. 3. Check the screws and fixtures of the machine-bedframe set are correctly fastened. Check the condition of the rope holding system and the pulley protection set. During the periodic revisions, check that the machine is clean, paying special attention to the ventilation fan and the electric components. The disc brake of the machine does not need to be adjusted. It is supplied set up and callipered. Should any adjustment be necessary, see the specific instructions for this device.

4.

5.6.1 Procedure for Replacing the Machine a) b) c) d) e) f) g) h) Lock the car in the upper locking support, and at the same time, hung the counterweight in the lower part of the shaft, without exceeding the maximum load allowed for the hooks located in the clear overhead. Put additional security slings in both frames. Disassemble the rope holding system and the traction pulley protection. One by one, get the ropes out of the traction pulley and rest them on the security sling. Disconnect the machine electric installation and disassemble the emergency system. Change the machine locating it suspended from the elevation system before disassembling the four fixing screws, trying not to exceed the maximum load permitted for the hooks located in the clear overhead. Get the machine out of the shaft being careful not to rest it on the car roof. In order to assemble the new machine, execute the inverse procedure.

v0.00, JULY 01

Page 43 / 46

MSCM02UK

Lift SCM 02

5.6.2 Procedure for Replacing the Pulley a) b) c) d) e) f) g) Lock the car in the upper locking support, and at the same time, hung the counterweight in the lower part of the shaft, without exceeding the maximum load allowed for the hooks located in the clear overhead. Put additional security slings in both frames. Disassemble the rope holding system and the traction pulley protection. Mark each one of the ropes with its present position in the traction pulley, so as to prevent them from crossing or entangling with each other when putting them back in their position. One by one, get the ropes out of the traction pulley and rest them on the security sling. Change the pulley. Introduce the ropes back into the pulley.

5.7 Speed Governor The following checks and tests should be carried out during the commissioning and maintenance inspections of the speed governor (see the installation and assembly dossier of the speed governor). 1. 2. 3. 4. Ensure that the speed governor functions reliably and safely. The bearings should be checked and lubricated every year. Check that the rope of the tension pulley remains tense and the slack rope switch works properly. Check that there is no excessive lengthening of the governor rope, which might trigger the safety contact in the tension pulley. If there is, shorten the rope. Make sure that the threads of the governor rope are not damaged. If they are, replace the rope. You can check their condition by observing if there is a fractured cord or its wire equivalent, in one metre of rope. In order to detect fractured cords or threads, pass a cotton rag along the rope. Occasionally, there may be threads fractured because of wear (abrasion), which must be detected visually. Check frequently and safely that the overspeed contact (governor contact) works properly. Check the rope hitches and the pulley grooves. Clean any strange particles from them to ensure the correct operation of the speed governor.

5. 6.

5.8 Buffers The following checks and tests should be carried out during the maintenance inspections of the buffers. 1. Ensure that there are buffers and check their state (see the dossier for maintenance, installation and use of the buffers).

5.9 Alarm Device and Emergency Stop The following checks and tests should be carried out during the maintenance inspections of the alarm device. 1. 2. 3. Check that it works and it can be heard from the outside of the lift shaft by the people responsible for the emergency operations. Ensure that all the stop switches (pit, car roof and revision pushbutton panels) work properly. Make sure that all the lift systems for alarm, emergency and rescue operations work properly (emergency lights, telephone, etc ...).

5.10 Rescue System 5.10.1 Checks and Tests To Be Carried Out During the Maintenance Inspections of the Rescue System 1. Check the correct operation and condition of the engaging system with the machine shaft and brake opening from the rescue panel. Check the towrope stretching (see the Installation and Adjustment Dossier of the Car Rescue System).

5.10.2 Checks and Tests on the Car and Access to the Car 1. 2. 3. 4. 5. 6. 7. 8. Check the general condition of the car and its frame. Ensure that the car is permanently lit. Check that the stop switch at the car roof works properly. The distance between the car door and the landing door must not exceed 20 millimetres, except for simultaneous automatic doors, where it can be up to 30 millimetres. Make sure that the car and landing doors have toe guards. Check that the lift does not start if the car door is open and that, once started, it stops when the door opens, except in the case of automatic doors with stop levelling device, where the levelling may take place while the door is opening. Check that the car door opens freely and that it is sensitive to obstacles. Check the car door contact closing.

v0.00, JULY 01

Page 44 / 46

MSCM02UK

Lift SCM 02

9. 10. 11. 12.

Ensure that the panels slide correctly and check the state of the guide shoes. If they are worn, replace them. Check that there is a load plate inside the car. Make sure that the landing and car pushbuttons (floor selection, open doors) work correctly. Check the correct operation of the two-way communication device (car - outside).

5.11 Counterweight 5.11.1 Checks and Tests on the Counterweight 1. 2. Check the state of the counterweight frame, especially the nuts, locknuts, guide shoe supports, etc. Check the rope clamps, nuts, locknuts and safety pins of the rope sockets or tighteners.

5.12 Guide Shoes 1. 2. Guide shoes should be replaced one by one, not simultaneously. When removing the old guide shoes, be careful not to move the frame too much, so that the new ones can be introduced easily.

5.13 Safety Gear 5.13.1 Checks and Tests on the Safety Gear 1. 2. Check the condition of the wedge boxes and ensure there are no strange elements inside. Check that the safety gear or wedge box are free of corrosion (see the installation and assembly dossier of wedge boxes).

5.14 Batteries 1. Check the good condition of the batteries and emergency batteries of the installation and make sure they have enough electric charge.

5.15 Load Weighing Device 5.15.1 Checks and Tests on the Load Weighing Device (see the installation dossier of the load weighing device). 5.16 Safety Electric Circuits (see the dossier for preassembled electrical installations). 5.16.1 Checks and Tests on the Safety Electric Circuits 1. 2. 3. 4. 5. Check that the ground wires that join the door frames, locks, motor casing and controller box are in good condition and are connected to the earth or to metal guides. Check that a grounding of the safety circuit conductors causes the lift to stop. Check the good working order of all safety devices. Make sure that they cause the lift to stop completely. If any, ensure that the electric rescue systems work properly. If necessary, check currents and voltages.

5.17 Signalling and Control Units (see the dossier for preassembled electrical installations). 5.17.1 Checks and Tests on the Signalling or Control Units Affecting Safety 1. 2. 3. In the case of closed shafts with blind, non-automatic landing doors, there should be a light to indicate that the car is on the other side of the door. Make sure that this light works at every floor. Check that the delay works, so that priority is given to calls from inside the car over calls from the floors. The final safety stop at the end of the travel should be caused by final limit switches other than those causing the normal stop at the upper and lower floors. Ensure that they work properly and that the car fits in the guides in such a way that its movement is not hindered. Check the car is properly levelled at all floors, both empty and with full load. Check the condition of relays and contactors, and how they react if a phase fails or if phases are reversed. Should the control unit have a fault storage device, check the last faults registered.

4. 5.

v0.00, JULY 01

Page 45 / 46

MSCM02UK

Lift SCM 02

5.18 Electric Cabinet 5.18.1 Checks and Tests on the Electric Cabinet 1. 2. 3. 4. 5. The electric cabinet should have electric lighting and a safety switch to stop the lift during inspection. Make sure it works properly. Check the main switch, contactors, relays, fuses and the level of artificial lighting. Check that the access to the cabinet is safe. Check the condition of the cabinet locks and make sure it is possible to close it without a key. After every inspection leave the access to the electric cabinet free.

v0.00, JULY 01

Page 46 / 46

MSCM02UK

MP SPAIN HEAD OFFICES Pabelln MP C/ Leonardo Da Vinci, TA 13 Isla de la Cartuja - 41092 Sevilla Tel. + 34.954.63.05.62 Fax. +34 954 65.79.55 e-mail: macsa@macpuarsa.es Contact: Sr. Antonio Garca de Alvear FACTORIES IN SEVILLE ELECTRONIC and MECHANIC Pol. Ind. Navisa, C/E 41006 Sevilla Tel. +34.954 93 28 40 Fax. +34.954 92 58 32

BRANCH OFFICES IN SPAIN MP BARCELONA Contact : Sr. Daniel Rodriguez e - mail : mpbarna@macpuarsa.es Tel. : + 34 93 7317333 Fax : + 34 93 7310838 Address : Pol. Can Parellada, c\ Coln 485, nave 10 / 08228 Les Fonts de Terrassa . Barcelona MP BILBAO Contact : Sr. Octavio Prez e - mail : mpnorte@macpuarsa.es Tel. : + 34 94 6313585 Fax : + 34 94 6313529 Address : Pol. San Lorenzo, Pabelln 5 48390 Beda Vizcaya MP MADRID Contact : Sr. Enrique Fuentes e - mail : mpcentro@macpuarsa.es Tel. : + 34 91 3294943 Fax : + 34 91 3293719 Address : Pol. Fin de Semana c\ Gumersindo Llorente n 62 28022 - Madrid MP VALENCIA Contact : Sr. Pablo Montes e - mail : mplevante@macpuarsa.es Tel. : + 34 96 1272540 Fax : + 34 96 1272528 Address : Pol. N 1 de Catarroja c\ Proyecto 32, nave 2C 46470 Catarroja - Valencia

AFFILIATED COMPANIES MP AUSTRIA Contact : Sr. Alvaro Rein e - mail : mp.austria@ikano.at Tel. : + 43 - 2236 - 865626 Fax : + 43 - 2236 - 86562620 Address : Triesterstrasse, 14 2351 Wiener Neudorf, Austria Web : www.mp-deutschland.de MP CZECH Contact : Sr. Pavel Dvorsky e - mail : prada@terminal.cz Tel. : + 420 2 6721 9303 Fax : + 420 2 7175 0659 Address : Prask 18 102 00 Praha 10 Repblica Checa MP GERMANY GMBH Contact : Sr. Peter Erdmann e - mail : berlin@mp-deutschland.de Tel. : + 49 30 6606100 Fax : + 49 30 66061060 Address : Krokusstrasse 9, 12357 - Berln Alemania Web : www.mp-deutschland.de MP FRANCE Contact : Sr. Xavier Malssigne e - mail : mac-puarsa-france@wanadoo.fr Tel. : + 01 41 474230 Fax : + 01 41 470488 Address : 94 Avenue du Vieux Chemin Saint Dennis / Site Artisanal, 92230 Gennevilliers - Francia MP GREECE Contact : Sr. J. Antonio R. Toquero e - mail : macpuhel@netor.gr Tel. : + 30 1 2840155 Fax : + 30 1 2845183 Address : 461, Irakliou Ave. 14122 N. Irakliou, Atenas Grecia MP ITALY Contact : Sr. Alberto Sordi e - mail : mp.italia@galactica.it Tel. : + 39 039 792100 + 39 039 792154 Fax : + 39 039 791912 Address : Via Lodi 1 Muggio, Milan, Italia MP HOLLAND Contact : Sr. Rowan Lebbink e - mail : r.lebbink@macpuarsa.nl Tel. : + 31 227 600 400 Fax : + 31 227 600 090 Address : De Stek 8b 1771 SP WIERINGERWERF Holanda MP POLAND Contact : Sr. Wieslaw Mielcarski e - mail : promp@prolift.com.pl Tel. : + 48 61 8475611 Fax : + 48 61 8478249 Address : 60 - 536 Poznan ul. Koscielna 19 Polonia MP PORTUGAL (OPORTO) Contact : Sr. Jos Guerra e - mail : diginorte@email.telepac.pt Tel. : + 351 2 7117971 Fax : + 351 2 7120949 Address : Rua das Lasge, 166 Z. Ind. San Caetano, Valadares Oporto - Portugal

MP PORTUGAL (LISBOA) Contact : Sr. Jos Guerra e - mail : Tel. : + 351 1 4843078 Fax : + 351 1 4843087 Address : Bairro 16 Novembro, lote 50 1 sq Tires 2775 Parede, Portugal

MP UK Contact e - mail Tel. Fax Address

: Sr. Gary Giltbertson : postbox@mpuk.demon.co.uk : + 44 0 2084660810 : + 44 0 2084660737 : 13/14 Chartwell Business Centre The Avenue Bromley Kent BR 1 2BS

HYDRAULIC Pol. Ind. El Pino, Parcela 16, n1-3 41016 Sevilla Tel. +34.954 52 72 28 Fax. +34 954 25 89 59

MP ARGENTINA Contact : Sr. Abraham Lera e - mail : alera@mparg.com.ar Tel. : + 54 11 43011283 Fax : + 54 11 43032321 Address : San Antonio, 1111/15/19 1276 Capital Federal Buenos Aires, Argentina MP BRAZIL Contact : Sr. Paulo Pimentel e - mail : jlhc@uol.com.br Tel. : + 55 11 58903338 / 58911245 Fax : + 5511 58903308 Address : Av. Guido Caloi, 1985, G-8 CEP 05802 140 . Capela do Socorro Sao Paulo, SP - Brasil MP CHILE Contact : Sr. Patricio Mora e - mail : mpchile@entelchile.net Tel. : + 56 2 3611982 / 83 Fax : + 56 2 3611984 Address : Edificio Puerto 1 Local 3 San Francisco 251 Santiago (Centro) - Chile MP CHINA Contact : Sr. Shan Yue e - mail : mpchina@public2.east.net.cn Tel. : + 8610 65915851 Fax : + 8610 65915852 Address : N.1003, The Gateway Building 10, Yabao Road, Chaoyang District 100020 Beijing - China MP THAILAND Contact : Sr. Eric Tanguy e - mail : mpthaiet@ksc.th.com Tel. : + 66 2 6530805 - 6 Fax : + 66 2 6530807 Address : Suite 1912, level 19, 140 One Pacific Place Bldg., Sukhumvit Road . Klongtoey 10110 Bangkok - Tailandia MP TURKIA Contact : Sr. Patricio Mora e - mail : mpchile@entelchile.net Tel. : + 56 2 3611982 / 83 Fax : + 56 2 3611984 Address : Edificio Puerto 1 Local 3 San Francisco 251 Santiago (Centro) - Chile MP SOUTH AFRICA Contact : Sr. Tony Barbosa e - mail : Tel. : + 271 2 3253234 Fax : + 271 2 3256266 Address : 28 Visagie Street, Guaranty House 2 planta, Pretoria Central Repblica Sudafrica MP AUSTRALIA Contact : Sr. Mark Barter e - mail : mb@webmail.com.au Tel. : + 612 99600016 Fax : + 612 99393247 Address : Going up lifts.Pty Limited 17, level 1 Bridgepoint, Brady Street Mosman, 2088 Sidney - New South Wales, Australia

DOORS Pol. Ind. Alcal 10 Ctra. Sevilla - Mlaga km 6,3 41500 Alcal de Guadaira Tel. +34.955 63 58 30 Fax. +34.955 63 16 19

FACTORIES IN ZARAGOZA LOGSTICA Pol. Ind. El Aguila Autova de Logroo km 13,4 - naves 14 - 20 50180 Utebo - Zaragoza Tel. +34. 976 78 82 61 Fax. +34. 976 78 81 53 e-mail: puarsa@macpuarsa.es Contact: Sr. Santiago Royo ESPECIAL LIFT Pol. Malpica Alfindn, C/H, n 21 - 23 50171 La Puebla de Alfindn - Zaragoza Tel. +34.976 10 77 60 Fax. +34.976 10 71 24

Mechanical rescue system LRM-101/A4


(for SCM-02 and SCM-07)

Technical dossier
v2.02, NOV. 02 English / RMA4SCMUk

Installation - Assembly - Commissioning Use - Maintenance - Repair

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

INDEX 0. SAFETY MEASURES

1. COMPONENTS DESCRIPTION

2. RESCUE SYSTEM INSTALLATION

3. RESCUE SYSTEM ADJUSTMENT

4. RESCUE SYSTEM MAINTENANCE

5. SYSTEM FEATURES AND USE MANUAL: Passenger Rescue Operation

v2.02, NOV. 02

Pag . 2 /10

RMA4SCMUk

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

0. SAFETY MEASURES

ASSEMBLY MUST BE PERFORMED BY TWO OPERATORS

Obligatory protection of the head

Obligatory protection of feet

Obligatory protection of hands

EXECUTE ALL OPERATIONS OF THIS DOSSIER WITH THE CAR ABOVE, FROM THE CAR ROOF AND WITH THE COUNTERWEIGHT NEXT TO THE BUFFERS..

DO NOT LOAD THE CAR EXCESSIVELY DURING THE INSTALLATION PROCESS AND SYSTEM ADJUSTMENT.

v2.02, NOV. 02

Pag . 3 /10

RMA4SCMUk

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

1. COMPONENTS DESCRIPTION: The mechanical rescue system A4 for SASSI LEO MACHINE following parts: is composed of the

A) MACHINE SUB-ASSEMBLY It is the four-column part. It is placed on the machine, once the rescue pinion, the machine safety contact and the encoder are installed on its support.

B) CABINET SUB-ASSEMBLY It is the component fixed to the upper compartment of the electric cabinet using four screws.

C) FLEXIBLE ROPE + SHEATH It connects the Machine Sub-assembly to the Cabinet Sub-assembly. It transmits the turning torque from the controller to the machine.

D)

METAL BRAKE FLEXIBLE CABLE It connects the Machine Sub-assembly to the Cabinet Sub-assembly. Used to release the brake and operate on the clutch at the same time.

v2.02, NOV. 02

Pag . 4 /10

RMA4SCMUk

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

2. RESCUE SYSTEM INSTALLATION 2.0) PREREQUISITE: The rescue pinion, the encoder and the safety contact (supplied together with the machine) should be correctly assembled on its support. See Pre-assembled Electrical Installation Dossier.

2.1) INTRODUCE the Cabinet Subassembly from the inside part of the shaft and fix using four side screws.

2.2) ASSEMBLE the Machine Sub-assembly on the machine, and fix through the threaded columns in the housings of the blue screws of the machine body. NOTE: Loose the nuts of union between the sheet of the rescue and the columns, and tighten them after ensuring that the square shaft slides and enters correctly in the rescue pin of rescue.

NOTE: Fix the hoops in order to lift the machine, under the columns of a lower length.

v2.02, NOV. 02

Pag . 5 /10

RMA4SCMUk

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

Fix the square piece supplied to the brake bar of the machine, as shown in the picture. >

NOTE: CHECK that the machine brake opens when pushing the lever DOWNWARDS. Otherwise, please contact MP After-Sales Department (To receive instructions on how to change the tripping direction).

< 2.3) CONNECT the horizontal lever of the Cabinet sub-assembly and the Machine Sub-assembly levers to the metal brake flexible cable. The plastic sheath of the brake flexible cable is installed between the rear part of the cabinet and the Z-piece of the Machine Sub-assembly. The set-pin is fixed at the end of the brake flexible cable on the machine side.

2.4) CONNECT both sub-assemblies to the metal flexible shaft and its sheath, inserting the square ends into the pinions.. (In the extreme of machine: In the right hand setting, the cable is connected in the opposite side to the brake, and in the "left hand setting, in the same side; the Machine Sub-assembly already comes assembled from factory according to the adequate setting)

v2.02, NOV. 02

Pag . 6 /10

RMA4SCMUk

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

NOTE: For a better operation of the flexible shaft, fix it, by means of the plastic band supplied, to the angular piece of the machine bedframe

3) RESCUE SYSTEM ADJUSTMENT 3.1) THE CABINET Adjust the position of the support plate of the wheel in relation to the wheel extension piece bushing. To do that, move the wheel while tightening screws and nuts and check the movement. 3.2) THE MACHINE Adjust the position of the Machine Sub-assembly plate (relieving and tightening columns) so that the square shaft placed in the rescue pinion moves freely. Adjust the levers: a) Place the machine trigger lever at 108 mm, between the brake flexible cable set-pin base and the brake flexible cable Z-support. See figure (NOTE: brake flexible cable Z- support should not be in contact with the machine, as to avoid vibrations). b) Self-locking nut of the threaded rod triggering the brake bar on the machine should be fixed at 5 mm of its actuation point. See figure.

v2.02, NOV. 02

Pag . 7 /10

RMA4SCMUk

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

c) Using the upper threaded rod nuts, place the pinion trigger lever (upper lever), in such a way that the notched wheel of the pinion (Z=23) is 3 mm from the gear int egral to the machine (Z=62).

Adjust the position of the machine contact on its support in height and depth (using the thread), in such a way that the pinion operates on the contact when moving downwards:

v2.02, NOV. 02

Pag . 8 /10

RMA4SCMUk

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

4) RESCUE SYSTEM MAINTENANCE During the periodic revisions of the lift: - Check the wheel moves easily. - Check the brake flexible cable is correctly tightened. - Ensure that dimensions and distances are respected regarding point 3, especially after executing a passenger rescue operation. - Ensure that all the system springs are in good condition.

5) SYSTEM FEATURES AND USE MANUAL: Passenger Rescue Operation The mechanical rescue system of the SCM-02 lift is capable of moving the car manually (using the wheel placed in the controller) in both directions, regardless of the load: Bidirectional System. (Provided that load does not exceed 125% of the rated load) In case of compensated load (car load equal to half the rated load) the force necessary to move the car in any direction will be similar. When the load in the lift is unbalanced, it will be easier to move the wheel in any direction. It is recommended to execute the rescue operation, moving the car in the most favourable direction (should that be possible), since too much effort will not be necessary and the time employed will be reduced. WARNING: In some cases, it may not be necessary to make an effort on the wheel to move the car; hold the wheel and release slowly, as to prevent the car overspeed. The system operates as follows: When pushing the wheel, the lever system of the Machine Sub-assembly operates and makes the rescue pinion to descend, opening the machine safety contact, and then, another lever of the mechanism opens the brake. From that moment, you control the car movement through the wheel. If you release the wheel, the system springs (in the cabinet, Machine Sub-assembly, pinion and the machine brake itself) make the system go back to its initial position. NOTES: 1) When pushing the wheel, if you observe it is difficult to take it to the end, the rescue pinion may not be lowering, possibly because its teeth interfere with that of the machine notched wheel. In this case, move the wheel slightly in both directions, while pushing it. 2) Due to the regenerative forces between the pinion and the machine notched wheel, they may be geared momentarily, even though the brake is released. If you move the wheel slightly once it is completely out, the pinion goes back to its original position. It is convenient to grease the rescue pinion of the machine.

v2.02, NOV. 02

Pag . 9 /10

RMA4SCMUk

TECHNICAL DOSSIER
Mechanical rescue system A4 for SCM

PROCEDURE FOR A PASSENGERS RESCUE OPERATION: 1. Contact the lift technician. SAFETY DEVICES should always remain ACTIVE. 2. TURN OFF THE MAIN SWITCH OF THE LIFT in the upper compartment of the electric cabinet, next to the lift door on the last floor. 3. CHECK TO SEE THE POSITION OF THE CAR. TRY TO CALM TRAPPED PASSENGERS DOWN and inform them that the rescue operation is going to take place and the car will move. Tell them no to try to open the doors or leave the car until they are told to do so safely. 4. CHECK THAT ALL LANDING DOORS ARE CLOSED AND BLOCKED AND CAR DOORS ARE CLOSED. Put up an OUT OF ORDER sign at each entrance. 5. LOCATE THE WHEEL WHICH IS UNASSEMBLED INSIDE THE CABINET AND SCREW. 6. RELEASE THE MACHINE BRAKE, PUSHING THE LEVER VERY SLOWLY and move it to turn the pulley manually.

WARNING: It may be necessary to turn the wheel slightly in both directions, while pushed, so that the system completely gears. The wheel should be pushed to the end.

WARNING : The car may go up or down by itself; in the event of car overspeed,take the wheel out immediately. If the car is blocked by the safety gear operation, or if it does not move, contact a qualified technician.

7. RELEASE THE BRAKE ONCE THE POSITION IS REACHED. THE CAR SHOULD REMAIN WITHIN THE INTERLOCK AREA; the level LED, installed in the upper compartment, lights up when the car is at floor level. When releasing the brake, once the position is reached, move the wheel in both directions and make sure it does turn freely. 8. UNLOCK AND OPEN LANDING DOORS USING THE EMERGENCY KEY to free the passengers. (Only trained staff familiar with

the rescue procedure are authorised to use this key). 8.1 LOCATE THE DOOR RELEASE TRIANGLE AT THE DOOR FRAME. All doors have a door release triangle. In the case of MACPUARSA doors, it is located at the door lintel. 8.2 INSERT THE KEY INTO THE TRIANGLE, to engage the mechanism. TURN THE KEY IN THE APPROPRIATE DIRECTION TO RELEASE THE DOOR and OPEN THE DOOR by pressing the door edge manually. 8.3 Once the landing door is open, THE CAR DOOR IS NO LONGER BLOCKED and it can be opened manually without the key. WARNING: If the car is not exactly at floor level, pay special attention to protect the passengers when leaving the car. 9. Once the passengers are out, make sure that ALL DOORS ARE CLOSED AND CORRECTLY BLOCKED. LEAVE ALL DEVICES AND RESCUE SYSTEM OPERATIONS BACK TO THEIR INITIAL POSITION. 10. WARN THE TECHNICAL DEPARTMENT so that the lift is checked before it is restarted .

WARNING: The lift should not have power supply until the assistance of the technical department.

C
v2.02, NOV. 02 Pag . 10 /10 RMA4SCMUk

PRODUCT TECHNICAL SPECIFICATIONS


PLATE TWO-PANEL CENTRAL-OPENING 3VF REVECO II OPERATOR

GENERAL DESCRIPTION 2-panel central-opening car door operator, supplied with 230 Vac single-phase voltage. It is controlled by an electronic system enabling speed regulation through 3VF frequency variation/voltage variation. Reading of door speed, position and direction of movement is carried out through double pulse encoder, integrated with the electronic circuit. There are no positioning microswitches. Views of the operator

Noteworthy innovations: Considerable reduction in operator noise level. Elimination of vibrations and electrical noises thanks to the new VVVF control. Adjustment of braking ramps and sensitivity by potentiometers. Wide door thrust and energy range adjustment. Infra-red communication using IRDA port. Greater operational robustness (supports anomalous situations in extreme operating conditions in temperatures up to 85 and voltages up to 260 V AC). Complies with future standards for electromagnetic compatibility for the lift sector (prEN 12015:2001 and prEN 12016:2001). Temperature detecting device to protect the motor from overheating.

V0.00,ENE.04

FTORIIC23VFUK

1/5

PRODUCT TECHNICAL SPECIFICATIONS


PLATE TWO-PANEL CENTRAL-OPENING 3VF REVECO II OPERATOR

TWO-PANEL CENTRAL-OPENING 3VF REVECO II AUTOMATIC CAR DOOR


GUIDE PLATE Fixing distances from operator to car roof

2
GREEN ALIGNMENT POINT AXIS
~

PANEL

TOTAL HEIGHT 2460

GREEN ALIGNMENT POINT OF THE OPERATOR

STANDARD CAR HEIGHT 2200

CLEAR ENTRANCE HEIGHT 2000

LINTEL

SILL DIMENSION A CAR DOOR B

STANDARD PANEL HEIGHT 2010

CAR JAMB

Installation of the operator on the car roof: CLEAR ENTRANCE LANDING DOOR PLATE 1. Horizontal regulation: The green alignment point must be centred with car jamb and with the door suspension green point (Landing door). Keep a 5 mm distance between panels, and between panels and car jamb with the door open. In MP cars install the operator at a distance of 2 mm, from the car roof rim. S In cars not manufactured by MP, the distance of 2 mm must be modified in relation with car door jamb width. 2. Vertical regulation: The operator is supplied already adjusted for standard MP cars, with an operator fastening height of 2200 mm, maintaining the distance of 21565 mm between the green alignment point of the operator and the top of the door track. S In cars with a standard door height of 2010 and other fastening heights different to 2200, adjust the height of the operator brackets, to maintain the distance of 21565 mm. S In cars with door heights over 2010, increase the distance of 2156 depending on the increase in door height. NOTE: RESPECT THE LINTEL DIMENSIONS AS TO AVOID INTERFERENCES IN THE OPERATOR. In cars not manufactured by MP, it is necessary to keep the relation between the operator fixation height (2200 mm, in standard MP car) and lintel maximum measures (2160 mm height, and 21 mm wide in the 115 mm upper side), also the relation between the jamb width (37 mm in MP cars) and the distance from the car roof rim (2 mm).

DIMENSIONS (mm) : Model OR2C2XXX Clear Version Plate Guide Motor Dim. Entrance XXX A (1) POSITIONS FOR FIXING SET SQUARES
(2)

DOOR WEIGHT (Kg)

B
F1 F2 F3 PANELS SILL Operator

PACKING Dimensions (mm)


(3)

+ Panels +Panels Standard Optional (e=1 mm) (e=1.2 mm) 59 65 75 78 62 68 79 82

070 080 090 100


(1) (2) (3)

700 800 900 1000

1310 1450 1600 1700

1410 1610 1810 2010

78 78 78 78

1460 1660 1860 2060

48 59 74 74

560 660 760 860

700 800 900 1000

850 950 1050 1150

380 430 480 530

1425 1625 1825 2025

35 39 42 43

1430x370x610 1800x370x610 2300x370x610 2300x370x610

Dimension A is the distance between the ends of both sides (guide ends or open car panels, depending on the case). Values in shaded boxes correspond to the position of set squares, which is pre-defined at the factory. Packing dimensions (length x width x height). Packed product weight: add 4 kg to the operator weight. V0.00,ENE.04 FTORIIC23VFUK

2/5

2156

PRODUCT TECHNICAL SPECIFICATIONS


PLATE
Electric connection scheme: Bank of microswitches Potentiometers Infrared receiver Group of Leds

TWO-PANEL CENTRAL-OPENING 3VF REVECO II OPERATOR

LED No. 1

SERIAL PORT FOR FIRMWARE PROGRAMMING

SWITCH SWITCH CONNECTION


U TO1 V

P2

U V W T01 T02

MOTOR

M3 230 V

P5
CONFIGURATION OF MODE PRESENCE OF OBSTACLE RELAY (NC/NO)

TO2 W

LED No.1

FUSES (F1,F2) 2A

T01,T02 (White wires): PROTECTION THERMO-SWITCH (NC) MODEL OF DOOR MOTOR PHASES U= GREY V= BROWN W= BLACK U= BROWN V= GREY W= BLACK

F2
BOX INTERNAL SIDE

F1

T2H/T3H (RIGHT)

OB2 OBX N.O.N.C.

V1

V2

C1

C2

C3

C4

T2H/T3H (LEFT) C2H/C4H

P12
SCC DOOR SAFETY SERIES CONTACT CONNECTION (TO CONTROL UNIT)
OB2 OBX V1 V2 C1 C2 C3 C4 (*) (*)

GENERAL ELECTRICAL INSTALLATION


GREEN-YELLOW
(**)
(FOT)

MP ELECTRICAL INSTALLATION
BROWN BROWN

V1-V2:

SUPPLY 230 Vac 10%

ORANGE

GREEN

GREEN

BLACK

BLUE

RED

C1-C2 AND C3-C4: OPEN/CLOSE SIGNAL, ACCORDING TO OPERATING MODE TABLE: A,B,...... (*) C3 AND C4 ONLY WILL BE WIRED UP WHEN OPERATING LIKE MODE: B OB2- OBX: DOOR OPENING CONTACTS 30Vdc,4 A/250 Vac, 2 A (**) INSERT CONTACTS GIVING DOOR OPENING COMMAND (example: photocell) SCC: CONNECTOR FOR SAFETY CONTACT (door series)

105-CR2

106-CR2

PAP2-CR2

221-CR3

222-CR3 222-CC3

105-CH2

106-CH2

PAP

2-CR2

MP INSPECTION BOX

+24 Vdc

221-CC3

2-CC2

MP CONTROL UNIT

OPENING AND CLOSING OPERATING MODE MODE Connections: C1,C2 CAM SIGNAL: OPEN DOOR .............................. (C1-C2)= 0 Vac/Vdc CLOSE DOOR ............................ (C1-C2)= 48 220 Vac/Vdc OPEN DOOR....................... CLOSE DOOR..................... LOW CLOSING SPEED......... NO MOVEMENT OF DOOR.... RESERVED RESERVED (1) FACTORY-DEFINED OPERATING MODE (2) FACTORY OPERATING MODE WHEN MP ELECTRICAL INSTALLATION IS MBII (3) FOR CHANGING THE OPERATING MODE USE TERMINAL PDA (INFRARED) (C1,C2)= (C1,C2)= (C1,C2)= (C1,C2)= 0 Vac 48 220 Vac 48 220 Vac 0 Vac / / / / Vdc........ Vdc ....... Vdc........ Vdc........ Connections: C3,C4 ADDITIONAL SIGN : LOW CLOSING SPEED = 48 220 (NO DETECTION OF OBSTACLE) and and and and (C3,C4)= (C3,C4)= (C3,C4)= (C3,C4)= 48 220 0 48 220 0

MODE: A(1)

0Vp-CC3

223-CR3

223-CR3

0Vp-CR3

Vac / Vdc.

MODE: B(2) C D NOTES:

Vac / Vdc Vac / Vdc Vac / Vdc Vac/Vdc

V0.00,ENE.04

FTORIIC23VFUK

3/5

PRODUCT TECHNICAL SPECIFICATIONS


PLATE TWO-PANEL CENTRAL-OPENING 3VF REVECO II OPERATOR

CONFIGURATION POSSIBILITIES: (Clear entrance, type of landing door, opening and closing speed, sensitivity to obstacles). Adhesive label for the identification of the operator controls and display of controls:
MICROINTERRUPTORES / MICROSWITCHES
DOOR SIZE READING PROCESS

OPERADOR 3VF REVECO-II /

3VF REVECO-II OPERATOR


POTENCIOMETER
FRENADA EN CIERRE BRAKING IN CLOSING
PROGRESIVA PROGRESSIVE 6 8 4 3 2 1 5 7
ASCENSORES

1 2 3 4

ON: PROCESO LECTURA TAMAO PUERTA / OFF: OPERACIN NORMAL /

NORMAL OPERATION SEMI-AUTOMATIC LANDING DOOR AUTOMATIC LANDING DOOR

ON: PUERTA DE RELLANO SEMIAUTOMTICA / OFF: PUERTA DE RELLANO AUTOMTICA / ON: VELOCIDAD APERTURA LENTA / OFF: VELOCIDAD APERTURA RPIDA / ON: VELOCIDAD CIERRE LENTA / OFF: VELOCIDAD CIERRE RPIDA / MODELO DE PUERTA TYPE OF DOOR

POTENCIMETROS /
SENSIBILIDAD SENSITIVITY

SLOW OPENING SPEED FAST OPENING SPEED

FRENADA EN APERTURA BRAKING IN OPENNIG


PROGRESIVA PROGRESSIVE 6 8 4 5 7

SLOW CLOSING SPEED FAST CLOSING SPEED ON / HIGH VOLTAGE ALTA / HIGH 6 7

5 6

T2H T3H C2H C4H

ESCALA REGULACIN POTENCIMETROS POTENCIOMETER ADJUSTING SCALE

5 4

1 2 3 4 5 6 7 8 ON

7 8

ON: RESTAURAR PARMETROS DE FBRICA / FACTORY SETTING OFF: OPERACIN NORMAL / NORMAL OPERATION ON: PROGRAMACIN FIRMWARE / FIRMWARE PROGRAMMING OFF: OPERACIN NORMAL /

3 2 1

NORMAL OPERATION

LECTOR INFRARROJOS INFRA-RED RECEIVER

BAJA / LOW

RPIDA / FAST

RPIDA / FAST

OFF

BANCO DE LEDS BANK OF LEDS

(IrDA)

BANCO DE MICROINTERRUPTORES BANK OF MICROSWITCHES

Description of microswitches functions

Group of leds

IRDA device for the configuration of parameters via infrared

Potentiometers for the analog adjustment of deceleration areas and door sensitivity

Bank of microswitches

Representative Speed-Time graph of the operator Reveco II (Eg.: Configuration of fast speed in opening and closing; and potentiometers in position 6)

Parametrization of opening/closing curves

OPENING

CLOSING OPENING
CLOSING

Maximum opening speed ....0.54 m/s. Maximum closing speed ........0.34 m/s. Opening time ..................2.86 s. Closing time......................4.03 s.

V1: Start-up speed (PDA) V2: Rated speed (Microswitch 3 or 4 / PDA) V3: Approach speed (PDA) V4: Stopping speed (PDA)

T1: Drive lever curve time: Door release (PDA) T2: Acceleration curve time (PDA) T3: Deceleration curve time (PDA) T4: Stopping curve time (PDA) PA: End of deceleration in opening (Potentiometer) PC: End of deceleration in closing (Potentiometer)

DISPLAY OF THE INFORMATION PROVIDED BY THE EQUIPMENT: (Leds, acoustic signals) Led Led Led Led Led Led Led 1: 2: 3: 4: 5: 6: 7: On: The equipment is powered (230 Vac, single-phase)/ Off: The equipment is not powered. No residual-internal stress. Blinking: Encoder pulse representation. On: Operator reading clear entrance./ Blinking: Door closing at slow speed (no detection of obstacles). On: Error, overtemperature in the motor. On: Clear entrance read, not supported./ Blinking: Error in E2PROM reading. On: Error, mains voltage low./ Blinking: Error, mains voltage high. On: Error, maximum travel time exceeded in opening or closing./ Blinking: Short circuit in motor output.

Acoustic signals (buzzer): Clear entrance reading process:During clear entrance reading:...................................... Buzzer blinking each 0.5 sec. End of clear entrance reading:- Correct (Finish OK): ........ 1 long 3-sec. whistle. - Incorrect (Finish KO): ...... Buzzer blinking each 0.1 sec. First movement in normal operation:.......................................................................... 2 sec. of buzzer blinking each 0.1 sec. Permanent error: ....................................................................................................... Buzzer on 0.2 sec. and off 10 sec. L Manual operation enabling (PDA):............................................................................Three short acoustic signals. L Manual operation disabling (PDA):........................................................................... Long acoustic signal.

V0.00,ENE.04

FTORIIC23VFUK

4/5

PRODUCT TECHNICAL SPECIFICATIONS


PLATE
GENERAL FEATURES Motor control through electronic system with voltage variation through 3VF frequency variation. Reading of door position via double pulse train encoder. Traditional control interface (connection to control unit); valid for any lift control unit. Removal of final limit switches and presence-of-obstacle contacts. Retiring lever for automatic landing door actuation. Door release before opening. Automatic reading of door size. Easy access for the regulation of speeds and sensitivity to obstacles. Mechanical elements reduction. State-of-the-art electronic components, 90% of them being superficially assembled. New supporting plate more rigid. Embossed Polyester Epoxi Paint.

TWO-PANEL SIDE-OPENING 3VF REVECO II OPERATOR

FUNCTIONAL FEATURES Frequency inverter (3VF) for the activation of a three-phase motor. Three-phase motor features. Type 125/40 IEC-34 900 rpm, Torque 35 Kgcm, V=230V For I=1,35 A, 50 Hz, IP-20 Class F Isolation. Protecting thermoswitch (NC). Supply: 230 Vac 10% single-phase; 50/60 Hz. Conventional control interface: V1-V2: Single-phase power supply 230 Vac 10%; 50/60 Hz. OB2-OBX: Door opening contacts. Output through voltage-free contact (NC from the factory) 30 Vdc, 4 A; 250 Vac, 2A. C1-C2 and C3-C4: Open/close signal, according to operating modes table (A, B,.....). S Earth. S SCC: Safety contact (door series). Includes a 16-bit Microcontroller with Three-phase PWM implementation hardware for Motor control. The Microcontroller has Flash Technology, which enables multiple in-circuit recordings. Complies with the Community directive on electromagnetic compatibility (CD 89/336/EEC). Includes all the electronics under a single card, regardless of the model of the governing motor. The response against the requirements in force concerning EMC (Electromagnetic Compatibility) is significantly improved. Parameter adjustment through microswitches and potentiometers (Analog Adjustment). Microswitches: Door size reading: the equipment reads door size and automatically calculates acceleration and deceleration ramps, without setting the parameters. All the factory-defined adjustment parameters are reestablish. Automatic or semi-automatic landing door configuration. Opening speed (slow or fast). Closing speed (slow or fast). Door model (T2H/C2H/T3H/C4H). Firmware programming. Potentiometers: Sensitivity to obstacles. Braking in opening: regulation of the moment when the door finishes deceleration in opening. Braking in closing: regulation of the moment when the door finishes deceleration in closing. IRDA configuration (Infra-Red Data Acquisition) for parameters reading and re-setting via infrared, through PAD device operating from the landing. Door size reading, type of operator and type of external door. Acceleration and deceleration zones. Opening (Fast/Slow): Speeds in the different periods. Times in the curves of the different periods. Closing (Fast/Slow) Speeds in the different periods. Times in the curves of the different periods. Operating mode. Torque in opening. Total lack of noise in the motor when using a switching frequency above the audible range. It operates in closed loop. It has incremental double pulse train encoder enabling to know the direction of door movement, position and actual speed in real time. This enables removing all traditional mechanical operation switches (final limit switches, sensitivity microswitches...). It includes output through relay contact (common and NO or NC) simulating the traditional sensitivity microswitch, enabled upon detection of an obstacle in door closing or photocell cut. It is thus possible to install the operator with any control unit. Sensitivity is adjustable. Automatic double fuse protection (independent). It has a switch to disconnect the equipment supply and to stop doors from moving. Includes a bank of leds and a buzzer to inform of the state of the equipment and of possible operating errors. Information supplied: State of the equipment supply. Representation of encoder pulses. State of the clear entrance or door size reading process. Error. Maximum travel time exceeded in opening or closing. Error in E2PROM reading. Error. Overtemperature in the motor. Clear entrance reading not supported. Error. Mains voltage low and high. Short circuit in the output motor. Permanent error. Identification of the first movement in normal control unit. (Position reset). Identification of the control state of the operator through PDA. Identification of door closing in slow speed (No detection of obstacles).

V0.00,ENE.04

FTORIIC23VFUK

5/5

PRODUCT TECHNICAL SPECIFICATIONS


PLATE TWO-PANEL SIDE-OPENING 3VF REVECO II OPERATOR

GENERAL DESCRIPTION 2-panel side-opening car door operator, supplied with 230 Vac single-phase voltage. It is controlled by an electronic system enabling speed regulation through 3VF frequency variation/voltage variation. Reading of door speed, position and direction of movement is carried out through double pulse encoder, integrated with the electronic circuit. There are no positioning microswitches. Views of the operator

Noteworthy innovations: Considerable reduction in operator noise level. Elimination of vibrations and electrical noises thanks to the new VVVF control. Adjustment of braking ramps and sensitivity by potentiometers. Wide door thrust and energy range adjustment. Infra-red communication using IRDA port. Greater operational robustness (supports anomalous situations in extreme operating conditions in temperatures up to 85 and voltages up to 260 V AC). Complies with future standards for electromagnetic compatibility for the lift sector (prEN 12015:2001 and prEN 12016:2001). Temperature detecting device to protect the motor from overheating.

V2.00,ENE.04

FTORIIT23VFUK

1/5

PRODUCT TECHNICAL SPECIFICATIONS


PLATE TWO-PANEL SIDE-OPENING 3VF REVECO II OPERATOR

TWO-PANEL SIDE-OPENING 3VF REVECO II AUTOMATIC CAR DOOR


PLATE Green alignment point of the operator Fixing distances from operator to car roof Green alignment point axis SILL TOTAL HEIGHT 2460 STANDARD CAR HEIGHT 2200 LINTEL CLEAR ENTRANCE HEIGHT 2000 STANDARD PANEL HEIGHT 2010 PACKING Dimensions (mm)
(4)

PANEL

Car slam post

CAR JAMB (DOOR OPEN)

DIMENSION A (START OF CLEAR ENTRANCE)

Green alignment point

TRAVEL = CLEAR ENTRANCE +10 PLATE -98 PLATE -311

Possible special position of motor and electronic card on the opening side, in cases of double landings at 90.

Installation of the operator on the car roof: 1. Horizontal regulation: The green alignment point must be aligned with the car slam post and with the door suspension green point (Landing door). Keep a 5 mm distance between panels, and between panels and car jamb with the door open. In MP cars install the operator at a distance of 17 mm, from the car roof rim. - In cars not manufactured by MP, the distance of 17 mm must be modified in relation with open door jamb width. 2. Vertical regulation: The operator is supplied already adjusted for standard MP cars, with an operator fastening height of 2200 mm, maintaining the distance of 21565 mm between the green alignment point of the operator and the top of the door track. S In cars with a standard door height of 2010 and other fastening heights different to 2200, adjust the height of the operator brackets, to maintain the distance of 21565 mm. S In cars with door heights over 2010, increase the distance of 2156 depending on the increase in door height. NOTE: RESPECT THE LINTEL DIMENSIONS AS TO AVOID INTERFERENCES IN THE OPERATOR. S In cars not manufactured by MP, it is necessary to keep the relation between the operator fixation height (2200 mm, in standard MP car) and lintel maximum measures (2160 mm height, and 21 mm wide in the 115 mm upper side), also the relation between the jamb width (37 mm in MP cars) and the distance from the car roof rim (17 mm).

PLATE

DIMENSIONS (mm) :
POSITIONS FOR FIXING SET SQUARES Model OR2T2XXX Version XXX
(2)

DOOR WEIGHT (Kg) + Panels Standard (e=1 mm) 59 61 64 71 74 79 +Panels Optional (e=1.2 mm) 62 64 67 74 77 83

Clear Entrance

Plate

Motor

Dim. A (1)

F1

F2

(3)

F3

(3)

F4

F5

F6

F7

Panels

Sill

Operator

070 075 080 085 090 100


(1)
(2) (3) (4)

700 750 800 850 900 1000

1120 1170 1270 1320 1420 1570

98 98 98 98 98 98

1085 1155 1235 1305 1385 1535

20 20 20 20 20 20

175 175 175 175 175 175

330 330 330 330 330 330

470 450 450 450 470 450

651 670 720 745 850 870

790 720 821 870 951 1000

945 840 940 990 1090 1120

380 405 430 455 480 530

1075 1150 1225 1300 1375 1525

36 37 39 40 42 45

1200x370x610 1200x370x610 1430x370x610 1430x370x610 1800x370x610 1800x370x610

Dimension A is the distance between the start of the clear entrance and the most outstanding point (the opening end of the operator or open car panels, depending on the case). Values in shaded boxes correspond to the position of set squares, which is pre-defined at the factory. Positions of set squares are only valid in the case of special position of the motor and electronic card in the opening side, when necessary in double landing at 90. Packing dimensions (length x width x height). Packed product weight: add 4 kg to the operator weight.

V2.00,ENE.04

FTORIIT23VFUK

2/5

PRODUCT TECHNICAL SPECIFICATIONS


PLATE
Electric connection scheme: Bank of microswitches Potentiometers Infrared receiver Group of Leds

TWO-PANEL SIDE-OPENING 3VF REVECO II OPERATOR

LED No. 1

SERIAL PORT FOR FIRMWARE PROGRAMMING

SWITCH
U TO1 V

P2

SWITCH CONNECTION

U V W T01 T02

MOTOR

M3 230 V

P5
CONFIGURATION OF MODE PRESENCE OF OBSTACLE RELAY (NC/NO) LED No.1 FUSES (F1,F2) 2A F1

TO2 W

T01,T02 (White wires): PROTECTION THERMO-SWITCH (NC) MODEL OF DOOR MOTOR PHASES U= GREY V= BROWN W= BLACK U= BROWN V= GREY W= BLACK

F2
BOX INTERNAL SIDE

T2H/T3H (RIGHT)

OB2 OBX N.O.N.C.

V1

V2

C1

C2

C3

C4

T2H/T3H (LEFT) C2H/C4H

P12
DOOR SAFETY SERIES CONTACT CONNECTION (TO CONTROL UNIT) SCC

OB2 OBX V1 V2

C1 C2 C3 C4 (*) (*)

GREEN-YELLOW

(**)

(FOT)

MP ELECTRICAL INSTALLATION
BROWN BROWN

GENERAL ELECTRICAL INSTALLATION


ORANGE

V1-V2:
RED BLUE

GREEN

GREEN

BLACK

SUPPLY 230 Vac 10%

C1-C2 y C3-C4: OPEN/CLOSE SIGNAL, ACCORDING TO OPERATING MODE TABLE: A,B,...... (*) C3 AND C4 ONLY WILL BE WIRED UP WHEN OPERATING LIKE MODE: B OB2- OBX: DOOR OPENING CONTACTS 30Vdc,4 A/250 Vac, 2 A (**) INSERT CONTACTS GIVING DOOR OPENING COMMAND (example: photocell)

105-CR2

106-CR2

PAP2-CR2

221-CR3

222-CR3 222-CC3

105-CH2

106-CH2

+24 Vdc

221-CC3

0Vp-CC3

223-CR3

MP CONTROL UNIT

PAP

223-CR3

0Vp-CR3

2-CR2

MP INSPECTION BOX

2-CC2

SCC: CONNECTOR FOR SAFETY CONTACT (door series)

OPENING AND CLOSING OPERATING MODE MODE Connections: C1,C2 CAM SIGNAL: OPEN DOOR .......................... CLOSE DOOR ........................ OPEN DOOR........................... CLOSE DOOR......................... LOW CLOSING SPEED............. NO MOVEMENT OF DOOR........ RESERVED RESERVED (1) FACTORY-DEFINED OPERATING MODE (2) FACTORY OPERATING MODE WHEN MP ELECTRICAL INSTALLATION IS MBII (3) FOR CHANGING THE OPERATING MODE USE TERMINAL PDA (INFRARED) Connections: C3,C4 ADDITIONAL SIGN : LOW CLOSING SPEED = 48 220 (NO DETECTION OF OBSTACLE) (C3,C4)= (C3,C4)= (C3,C4)= (C3,C4)= 48 220 0 48 220 0

MODE: A(1)

(C1-C2)= 0 (C1-C2)= 48 220 (C1,C2)= (C1,C2)= (C1,C2)= (C1,C2)= 0 48 220 48 220 0

Vac/Vdc Vac/Vdc Vac Vac Vac Vac / / / /

Vac / Vdc.

MODE: B(2) C D NOTES:

Vdc.............and Vdc ............and Vdc.............and Vdc.............and

Vac / Vdc Vac / Vdc Vac / Vdc Vac / Vdc

V2.00,ENE.04

FTORIIT23VFUK

3/5

PRODUCT TECHNICAL SPECIFICATIONS


PLATE TWO-PANEL SIDE-OPENING 3VF REVECO II OPERATOR

CONFIGURATION POSSIBILITIES: (Clear entrance, type of landing door, opening and closing speed, sensitivity to obstacles). Adhesive label for the identification of the operator controls and display of controls:
MICROINTERRUPTORES / MICROSWITCHES
DOOR SIZE READING PROCESS

OPERADOR 3VF REVECO-II /

3VF REVECO-II OPERATOR


POTENCIOMETER
FRENADA EN CIERRE BRAKING IN CLOSING
PROGRESIVA PROGRESSIVE 6 8 4 3 2 1 5 7
ASCENSORES

1 2 3 4

ON: PROCESO LECTURA TAMAO PUERTA / OFF: OPERACIN NORMAL /

NORMAL OPERATION SEMI-AUTOMATIC LANDING DOOR AUTOMATIC LANDING DOOR

ON: PUERTA DE RELLANO SEMIAUTOMTICA / OFF: PUERTA DE RELLANO AUTOMTICA / ON: VELOCIDAD APERTURA LENTA / OFF: VELOCIDAD APERTURA RPIDA / ON: VELOCIDAD CIERRE LENTA / OFF: VELOCIDAD CIERRE RPIDA / MODELO DE PUERTA TYPE OF DOOR

POTENCIMETROS /
SENSIBILIDAD SENSITIVITY

SLOW OPENING SPEED FAST OPENING SPEED

FRENADA EN APERTURA BRAKING IN OPENNIG


PROGRESIVA PROGRESSIVE 6 8 4 5 7

SLOW CLOSING SPEED FAST CLOSING SPEED ON / HIGH VOLTAGE ALTA / HIGH 6 7

5 6

T2H T3H C2H C4H

ESCALA REGULACIN POTENCIMETROS POTENCIOMETER ADJUSTING SCALE

5 4

1 2 3 4 5 6 7 8 ON

7 8

ON: RESTAURAR PARMETROS DE FBRICA / FACTORY SETTING OFF: OPERACIN NORMAL / NORMAL OPERATION ON: PROGRAMACIN FIRMWARE / FIRMWARE PROGRAMMING OFF: OPERACIN NORMAL /

3 2 1

NORMAL OPERATION

LECTOR INFRARROJOS INFRA-RED RECEIVER

BAJA / LOW

RPIDA / FAST

RPIDA / FAST

OFF

BANCO DE LEDS BANK OF LEDS

(IrDA)

BANCO DE MICROINTERRUPTORES BANK OF MICROSWITCHES

Description of microswitches functions

Group of leds

IRDA device for the configuration of parameters via infrared

Potentiometers for the analog adjustment of deceleration areas and door sensitivity

Bank of microswitches

Representative Speed-Time graph of the operator Reveco II (Eg.: Configuration of fast speed in opening and closing; and potentiometers in position 6)

Parametrization of opening/closing curves

OPENING

CLOSING OPENING
CLOSING

Maximum opening speed ....0.54 m/s. Maximum closing speed ........0.34 m/s. Opening time ..................2.86 s. Closing time......................4.03 s.

V1: Start-up speed (PDA) V2: Rated speed (Microswitch 3 or 4 / PDA) V3: Approach speed (PDA) V4: Stopping speed (PDA)

T1: Drive lever curve time: Door release (PDA) T2: Acceleration curve time (PDA) T3: Deceleration curve time (PDA) T4: Stopping curve time (PDA) PA: End of deceleration in opening (Potentiometer) PC: End of deceleration in closing (Potentiometer)

DISPLAY OF THE INFORMATION PROVIDED BY THE EQUIPMENT: (Leds, acoustic signals) Led Led Led Led Led Led Led 1: 2: 3: 4: 5: 6: 7: On: The equipment is powered (230 Vac, single-phase)/ Off: The equipment is not powered. No residual-internal stress. Blinking: Encoder pulse representation. On: Operator reading clear entrance./ Blinking: Door closing at slow speed (no detection of obstacles). On: Error, overtemperature in the motor. On: Clear entrance read, not supported./ Blinking: Error in E2PROM reading. On: Error, mains voltage low./ Blinking: Error, mains voltage high. On: Error, maximum travel time exceeded in opening or closing./ Blinking: Short circuit in motor output.

Acoustic signals (buzzer): Clear entrance reading process:During clear entrance reading:................................................Buzzer blinking each 0.5 sec. End of clear entrance reading:- Correct (Finish OK): .................1 long 3-sec. whistle. - Incorrect (Finish KO): ...............Buzzer blinking each 0.1 sec. First movement in normal operation:...................................................................................2 sec. of buzzer blinking each 0.1 sec. Permanent error: ................................................................................................................Buzzer on 0.2 sec. and off 10 sec. L Manual operation enabling (PDA):................................................................................. ..Three short acoustic signals. L Manual operation disabling (PDA):................................................................................... Long acoustic signal.

V2.00,ENE.04

FTORIIT23VFUK

4/5

PRODUCT TECHNICAL SPECIFICATIONS


PLATE
GENERAL FEATURES Motor control through electronic system with voltage variation through 3VF frequency variation. Reading of door position via double pulse train encoder. Traditional control interface (connection to control unit); valid for any lift control unit. Removal of final limit switches and presence-of-obstacle contacts. Retiring lever for automatic landing door actuation. Door release before opening. Automatic reading of door size. Easy access for the regulation of speeds and sensitivity to obstacles. Mechanical elements reduction. State-of-the-art electronic components, 90% of them being superficially assembled. New supporting plate more rigid. Embossed Polyester Epoxi Paint.

TWO-PANEL SIDE-OPENING 3VF REVECO II OPERATOR

FUNCTIONAL FEATURES Frequency inverter (3VF) for the activation of a three-phase motor. Three-phase motor features. Type 125/40 IEC-34 900 rpm, Torque 35 Kgcm, V=230V For I=1,35 A, 50 Hz, IP-20 Class F Isolation. Protecting thermoswitch (NC). Supply: 230 Vac 10% single-phase; 50/60 Hz. Conventional control interface: V1-V2: Single-phase power supply 230 Vac 10%; 50/60 Hz. OB2-OBX: Door opening contacts. Output through voltage-free contact (NC from the factory) 30 Vdc, 4 A; 250 Vac, 2A. C1-C2 and C3-C4: Open/close signal, according to operating modes table (A, B,.....). S Earth. S SCC: Safety contact (door series). Includes a 16-bit Microcontroller with Three-phase PWM implementation hardware for Motor control. The Microcontroller has Flash Technology, which enables multiple in-circuit recordings. Complies with the Community directive on electromagnetic compatibility (CD 89/336/EEC). Includes all the electronics under a single card, regardless of the model of the governing motor. The response against the requirements in force concerning EMC (Electromagnetic Compatibility) is significantly improved. Parameter adjustment through microswitches and potentiometers (Analog Adjustment). Microswitches: Door size reading: the equipment reads door size and automatically calculates acceleration and deceleration ramps, without setting the parameters. All the factory-defined adjustment parameters are reestablish. Automatic or semi-automatic landing door configuration. Opening speed (slow or fast). Closing speed (slow or fast). Door model (T2H/C2H/T3H/C4H). Firmware programming. Potentiometers: Sensitivity to obstacles. Braking in opening: regulation of the moment when the door finishes deceleration in opening. Braking in closing: regulation of the moment when the door finishes deceleration in closing. IRDA configuration (Infra-Red Data Acquisition) for parameters reading and re-setting via infrared, through PAD device operating from the landing. Door size reading, type of operator and type of external door. Acceleration and deceleration zones. Opening (Fast/Slow): Speeds in the different periods. Times in the curves of the different periods. Closing (Fast/Slow) Speeds in the different periods. Times in the curves of the different periods. Operating mode. Torque in opening. Total lack of noise in the motor when using a switching frequency above the audible range. It operates in closed loop. It has incremental double pulse train encoder enabling to know the direction of door movement, position and actual speed in real time. This enables removing all traditional mechanical operation switches (final limit switches, sensitivity microswitches...). It includes output through relay contact (common and NO or NC) simulating the traditional sensitivity microswitch, enabled upon detection of an obstacle in door closing or photocell cut. It is thus possible to install the operator with any control unit. Sensitivity is adjustable. Automatic double fuse protection (independent). It has a switch to disconnect the equipment supply and to stop doors from moving. Includes a bank of leds and a buzzer to inform of the state of the equipment and of possible operating errors. Information supplied: State of the equipment supply. Representation of encoder pulses. State of the clear entrance or door size reading process. Error. Maximum travel time exceeded in opening or closing. Error in E2PROM reading. Error. Overtemperature in the motor. Clear entrance reading not supported. Error. Mains voltage low and high. Short circuit in the output motor. Permanent error. Identification of the first movement in normal control unit. (Position reset). Identification of the control state of the operator through PDA. Identification of door closing in slow speed (No detection of obstacles).

V2.00,ENE.04

FTORIIT23VFUK

5/5

Pre-Assembled Electrical Installation For Machineroomless Lifts SCM

Technical Dossier
v1.31, MAR.03 English / MIEPSCMUK

Installation Assembly Commissioning Use Maintenance Repair

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

CONTENTS 1. GENERAL FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. INSTALLATION REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3. ELECTRIC CABINET. . . . . . . . . . . . . . . . . . . . . 3.1. Cabinet location and dimensions. . . . 3.2. Cabinet components. . . . . . . . . . . . . 3.3. Cabinet assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 2 4 6 6 7 8 9 10 10 11 12 13 14 15 16 17 18 18 19 19 20 21 22 23

4. ELECTRICAL INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1. Electrical installation general scheme. . . . . . . . . . . . . 4.2. Control panel general scheme. . . . . . . . . . . . . . . . . . 4.2.1. Identified wire connections in control panel. 4.3. Electrical protections scheme. . . . . . . . . . . . . . . . . . . 4.4. SCM electrical installation special elements. . . . . . . . . 4.4.1. Installation general lighting. . . . . . . . . . . . 4.4.2. Machine gear contact. . . . . . . . . . . . . . . . . 4.4.3. Car-to-guides interlock contacts. . . . . . . . . 4.4.4. Speed governor remote control. . . . . . . . . . 4.4.5. VK-2P load weighing device. . . . . . . . . . . . 4.4.6. Encoder connection. . . . . . . . . . . . . . . . . . 4.4.7. Machine supply. . . . . . . . . . . . . . . . . . . . . 4.4.8. Shaft installation layout and wiring. . . . . . . 5. OPTIONAL EQUIPMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1. Emergency electric control unit. . . . . . . . . . . . . . 5.2. Terminal box. . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.1. Without emergency electric control unit. 5.2.2. With emergency electric control unit. . . 5.3. Cabinet elevation system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ANNEX I. ABBREVIATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANNEX II. DIFFERENCES BETWEEN VERSIONS 1.21, JUN.02 AND 1.31, MAR.03. . . . . . . . . . . . . . . . . . . . . . . . .

V1.31,MAR.03

1 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

1. GENERAL FEATURES This product is designed for installations with the following features: Operation: electric traction drive. Location: interior. Machine situation: clear overhead. Control unit cabinet situation: next to landing door, at last floor Emergency operation: manual. No. of lifts: 1, 2. Rated speed: 1 m/s. Rated load: According to table. No. of floors: 2 to 16 Landing: simple and double. Control unit: MicroBASIC with 3VFMAC inverter. Power supply: Voltage: According to table. Mains frequency: 50 Hz Power: According to table. 2. INSTALLATION REQUIREMENTS Supply: on the last floor, for connection in the cabinet upper part. Features: cable cross-section and thermomagnetic protection according to table above. Rest of requirements, as in conventional installations. Since MicroBASIC circuit board is the control unit used for this installation, only modifications in relation to our conventional product are indicated below. The rest of the information coincides with that gathered in the MicroBASIC Pre-assembled Electrical Installation dossier. 3. ELECTRIC CABINET 3.1. Cabinet location and dimensions The cabinet should be installed on the last floor, next to the door frame, so that it becomes a part of it. The cabinet should be located at the side of the machine and the opening hand will correspond to the side of door where the cabinet is located. If the cabinet is installed at the right side of door, it will be a right-hand door and vice versa. General dimensions of the cabinet are shown in the figure. 3.2. Cabinet components There are two clearly differentiated parts in this cabinet, each of them having an independent door. - Upper Compartment : The installation electrical protections panel is located in this compartment, as well as all the electric elements which, in a conventional installation, are usually installed in the machine room, outside the electric cabinet. Elements necessary for the manual emergency operation are also installed here. Mains supply goes in through the upper part of this compartment and is connected to the corresponding terminals. Access to this compartment is only given both to the maintenance personnel and the building property. - Lower Compartment : It is the equivalent to the conventional electric cabinet. The control panel is installed in this compartment. Dimensions and silent elements included in it are the main differences in relation to a standard controller. Access to this compartment must be restricted to the maintenance staff; therefore, the door is supplied with a different lock from that of the upper compartment. NOTE: The figure in the right shows a right-hand controller.
180 385 2260

RATED LOAD POWER AVAILABLE VOLTAGES OUTSIDE SUPPLY CROSSSECTION (3 ONE-WIRE ROPES UNDER TUBE) EXTERNAL THERMOMAGNETIC PROTECTION

# 600Kg
10CV 400V 230V

# 1000Kg
15CV 400V

6mm2

10mm2

10mm2

25A

32A

32A

V1.31,MAR.03

2 / 23

1410

850

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

The following figure shows the electric elements layout in both parts of the cabinet and in the corresponding doors (some of these elements are optional). Cable input/output points are also indicated. This configuration may vary depending on the specifications of each installation. Drawing represents a right-hand controller.
Supply connection box Mains supply input

Level indicator Alarm indicator (in multiplex installations) Electrical protections Upper compartment

Emergency electric control unit box (optional)

TC

CA SALH SACB

Lighting box and power socket Intercom set (optional)

Room reserved for emergency mechanism

Upper door

Speed governor remote control key Upper-lower compartment connections Transformer AMB1 or AMB2 boards (according to installation)
BTST
FB FL FR

Control unit relays. Fuses. Main switch. Temperature probe

Lower compartment

MicroBASIC board

Lower door

Shaft and car installation input

Shaft and car installation connections Thermal probe and brake rectifier board Braking resistence cable outputs Inverter capacitors Braking resistance connection box

Speed governor remote control Machine room connections

Frequency inverter
SALV

Output filter Briefcase Contactors Machine supply input

Level indicator battery

V1.31,MAR.03

3 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

3.3. Cabinet assembly Before installing the cabinet, a braking resistance should be installed as shown in the left figure. For that purpose, the through-bolt should be a reference and should be fixed to the rear part of the control unit using the supplied self-tapping screws. Once the resistance is installed, cables must be introduced in the through-bolt and connected to terminals "B1 B2", arranged in the controller. See 3VFMAC dossier, chapter 10 EMC requirements . VERY IMPORTANT: The frequency inverter should be voltage-free when making the connection. Installation of the cabinet is similar to the assembly of landing door frames, as shown in the right figure. (See fixing details in the left figure of next page). Fixing of the cabinet sides is as follows: The side adjacent to the door must be fixed to the header, if any. Otherwise, fix to the door frame; for that purpose, M6 rivet nuts are provided in each side of the cabinet, which coincide with holes both in the header and in the door frame. To fix to wall use the securing pins, which have been removed from the door frame fixing. They must be screwed on the existing rivet nuts of the free side of cabinet.

Fixed bracket

Side fixed to header Bracket fixing sections

Through-bolt (Cable inputs)

Side fixed to wall

Braking resistance

Rear part of cabinet SCM cabinet

Front view of lower compartment

Braking resistance cable output, right hand.

SCM cabinet support (Similar to door track support)

Braking resistance cable output, left hand.

V1.31,MAR.03

B2 B1

Bracket fixing sections

Fixed bracket

4 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

When doors have a special height (clear entrance: 2100, 100mm higher than standard height), it is necessary to place an additional supplement on the cabinet upper part, so as to close the hole between the upper part of cabinet and the roof (see right figure).

Vertical fixing detail (rear view)

Supplement for closing the hole

Upper part

Together with the documentation you will find the following electrical danger sticker. Once the cabinet is installed, put it at the door of each cabinet compartment.

EN 60204 - 1
COLOCAR EN PUERTA DE ARMARIO ELCTRICO LOCATE AT ELECTRIC CABINET DOOR POSER SUR LA PORTE DE L'ARMOIRE ELECTRIQUE AN DER SCHALTSCHRANKTR ANBRINGEN LOKATIE OP DE BESTURINGSKAST DEUR COLOCAR NA PORTA DO ARMRIO ELCTRICO
Lower part

METTERLA NELLA PORTA DEL QUADRO DI MANOVRA

V1.31,MAR.03

5 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4. ELECTRICAL INSTALLATION 4.1. Electrical installation general scheme The electrical installation does not vary much from the conventional installation. The following schemes give an overview of the elements layout and connections, as well as the particular wiring of the upper and lower compartments. Special care should be taken to the shaft wiring installation, since the installation electromagnetic compatibility could be affected and it could also prevent car or doors from moving. This scheme shows how ropes must be installed to avoid the above-mentioned problems.
Through solid raceway

R,S,T,N,t supply Machine light

Upper final limit switch Through slotted raceway

Machine Upper terminal stopping switch

Cabinet U, V, W motor supply

3rd Floor

Travelling cables String of lights (optional)

2nd floor

Lower terminal stopping switch Shaft installation

Lower final limit switch

1st floor

V1.31,MAR.03

6 / 23

MIEPSCMUK

Upper rail
PIN 207
A1 A1 BYT11-1000

BAT

CLN

KRREV
A2

CHA_ CCA_

CBC_

PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

+ +
A2

KRL

208CC2
K1
FP
83 (63) 84 (64)
INH 220Vp

CRL RL2 RL1

T2 T1

T1
PIN 103

BYT11-1000

12

T2
SALV
A1

FB
11

KRL

A2 62 (22) 61 (21) 14

0Vdc LA1 62 (22)

KRLE K2

BYT11-1000

+24Vdc L+

TECHNICAL DOSSIER

MicroBASIC

k
j

KRFR
8(31) 1(11) 6(34) 3(14)

KRSE

17

12
1

KRREV

i h g f e d c b a
A1 A1

QIG 6A KRFR 2 1
A1 A1

11 12 KRNS

16
48Vs 0Vs 60Vs 110Vs 0Vp 220Vp

21

24

15
KRSE KRNS A A

3VFMAC1 - 10 / 15 (400Vac) SERIE F

32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17

208

A2

BYT11 - 1000

TS
20Vs

0Vdc 24Vdc

KSG

FL

0 Vdc

CE + CE -

KRL3

61 (21)

11
0

BTST
0Vs 20Vs 60Vs Us 14 11 A1 A2 48Vs 80Vs 110Vs 380Vp

7 MK2P KRFR 24 Vdc 2

37

COND
TRM
0Vp 220Vp

+ 24 Vdc

36

20Vs +24Vcc 60Vs 220Vp 110Vs 0Vcc 0Vs 0Vp

K1 KRNS

19
B

18

K1 A
35 34 A2 A2

K2

KRET
A2 A2

14

GRF

MBAS

13

3VFMAC1

K2

K1

de 11 13 13
L1 L2 L3

4.2. Control panel general scheme

KSG
14 11

Lower rail

B2 B1

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

53

54

53

54

12
K1
14

K2
14
T1 T2 T3

de 12

11

C KRSE
5 9 2

L1

L2

L3

RVAR 36V
1

T1

T2

T3

U V W C1 C2 R S T B1 B2

+24Vdc

EM2*

In case of MES only


111CC1 208CC2 11_CC1 PIN103 0Vdc

+24Vdc

FAL

+5Vdc

*
EM1 EM2 TS1 TS2 206 204 0 220 R S T
10CV-220V and 15CV-380V
91 107 216

Green

M 1

Yellow

C1+

Brown

C1-

C6
t
Upper rail
402 502 602 0Vdc 208 RD 111/B11X/S 302 402 RD 202 302
3VFMAC 34 35 ~2 ~1 (-) A1 K1 A2

U V W
Lower rail
0Vp 0Vs 48Vs 220Vp 60Vs 110Vs
RK
(+)

+ - C1+ C1- C2+ C2-

GRL
1
~1 (-) A1 K2 A2

LE-

Intermediate rail

Carril superior

KRLE

Intermediate rail

~2

RK

(+)

In case of cam only

CCS

CRD

CCA_

CHA_

11

14

LE+

CENC

Lower rail

V1.31,MAR.03
-

White Earth with flange

C2+

C2-

7 / 23

MIEPSCMUK

Identified rope. Connect to the Intermediate rail travelling cable CCA_ CC2 group

Intermediate rail

Intermediate rail

1 2 3 4 5

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.2.1. Identified wire connections in control panel The right figure shows a raceway inside which a series of identified wires should be connected once you have finished the electrical installation. These flag-type identifications show the corresponding connector and terminal where the spare wire must be connected, generally to MicroBASIC board connectors. A
Detail A: Identified wires connection
CC2
MICROBASIC

Identified wires are located here

208

Conectar a: Connect to:

208 - CC2

Conectar a: Connect to:

208 - CC2
Example of an identified wire

Identified wires, which can be found according to the requirements or options of the installation, are: All installations: < 208 - CC2 (NOTE: This wire shall have a quick coupling for connection to wire 208 of shaft installation). In installations with emergency electric control unit:

< <

11x/S - CC1 11_/B - CC1

In installations with double row of magnets: < 203 - CC2 In installations with fire-brigade operation: < 10 - CH1 < 9 - CC1 (in case of fire-brigade keyswitch in car) In installations with imminent departure, coming light, gong at each floor, multiplexed display: < A - CH1 < B - CH1 < C - CH1 < D - CH1 In installations with approach with open doors: < 00 - CC2 In installations compliant with DM236 (Italy): < 105 - CH1 Besides:

< < <

In each shaft installation there is another identified wire (208 - CC2) which should be connected to one of the other two wires getting to this terminal, through the quick connector supplied with it. Other wires may be connected if installation so requires. In this case, they should be indicated in the specific documentation of each installation. In all cases, two wires should be connected to each of the terminals indicated, that wired at the factory and the identified wire to be connected by the installer himself.

V1.31,MAR.03

8 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.3. Electrical protections scheme

SUPPLY

Earth terminal

R S T N t

F FA

R FF

QF QAH F N QAC F N QASM F N R S T

Shaft lighting

Car lighting

Cabinet lighting

210H 212H

210C 212C

210A 212A

FNH

FNC

FNA SALC

SALH

211H 212H NOA NCA

CAH

211C 212C

CAC

211A 212A

CAA

Upper compartment Lower compartment

R S T

Earth terminal

V1.31,MAR.03

9 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.4. SCM electrical installation special elements The electrical installation includes certain elements and the wiring, which the traditional installation does not have. 4.4.1. Installation general lighting
Lighting box internal circuitry
FNC
210C

LIGHTING BOX
210H 212H 210C 212C 210A 212A

SHA1
Microswitch at upper cabinet door Reactance under level indicator raceway

FNH
212C 210H 212H

FNA

FNH
210A 212A

FNC

FNA

IF1 IF2

SALC

5A / 250 Vac

10A / 250 Vac

SALH

SALC

XHA1

SALH

CAC

CAH

CAA

IF1 IF2

XF11
212 211 211H 212H NOA NCA 211C 212C 211A 212A 212 211

Fluorescent tube

211C 212C

211H 212H NOA NCA

211A 212A

CAH

CAC

CAA

R1

XF12
212 211

HA1
212 211

S1 TCA
To lower compartment through side top hat section
NCA NOA 212 211 212 211 212 211

Power socket Upper compartment Lower compartment

SHA2
Microswitch at upper cabinet door
IF1 IF2

CAH'

CAC' CAA'

A
211 212 211 212 211 212

NCA NOA 212 211

212 211

212 211

XHA2
211 212 CA NOA NCA 211 212

XF21
212 211 IF1 IF2 212 211

Fluorescent tube

R2

212 211

212 211

CAM RB

RB'

CAH

CAC

XF22 S2

HA2

211 212

211 212

211 212

211 212 CA NOA NCA

211 212 212 211

XF31
212 211

Fluorescent tube

R3

XF32
212 211

HA3

S3

HAM

HRB'

Set of reactances and starters located next to the inverter input filter, under MicroBASIC board. As to ensure sufficient light in the machine area, a screen should be installed on it, which will be enabled with the rest of the shaft lighting. Fixing of the screen will be made with the rings, plugs and hooks supplied with it and following the instructions in the inside. Fix the earth wire to the controller plate with a self-tapping screw.

TCF HRB

SALH Pit box

HAC
Car roof

Shaft and car installation

TCC

EM1 EM2

U V W t

Detail A

CAM

V1.31,MAR.03

10 / 23

212 211

BAT

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.4.2. Machine gear contact Wiring should be connected to a contact located on the machine, which in case of manual emergency operation, prevents movement of the machine during rescue operation. Figure shows connection of this contact to controller. A rope is provided together with the supply to perform this connection.

Lower compartment

EM1 EM2

U V W t

Machine gear contact Rope supplied

SEM

BAT

When this contact does not exist, fix a jumper between terminals EM1 and EM2.
Lower compartment

12 mB 12 mB 8 mB EM1

SEM EM2

8 mB

EM1 EM2 TS1 TS2 0V 220 206 204

SM
SM connector located on the left-hand bottom part of the control panel, with the rest of connectors corresponding to motor connections.

Wiring is different when installation includes Emergency Electric Control Unit (see point 5.1).

V1.31,MAR.03

11 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.4.3. Car-to-guides interlock contacts Wiring must be connected to 2 contacts preventing car from moving when locked on the guides during the machine maintenance operations. In principle, they should only be used in Macpuarsa complete lifts. In other cases, they should be bridged. Wiring and electric schemes
Car interlock contacts

SEC1
Inspection box

SEC2

102

Safety gear contact

Speed governor contact (in case it is in the car) Hatch contact

Inspection box travelling cable To controller

Interlock 2 contact

Interlock 1 contact

STOP

SIR SPRS SPRB


Inspection box

220

Slack rope contact

Safety series:
PCB MicroBASIC Machine room Car

Inspection box

SIR SEC1 SAFC SPRS SPRB

STOP

110 Vs

FM 15

RMT1 5 6 12 EM1

SEM EM2 8 102


Car Shaft

SAC

SLVC

SCTC

SEC2

PCB MicroBASIC

Shaft

STOPF 103 STLH SFI

Shaft

106

SCC

105

SCE

104

SP

SFS

SCTH

* STLH

SLVH 220

PIN 103

* Double speed governor voltage contact in shaft. VERY IMPORTANT: Before closing the interlock bolts, make sure the installation is under inspection mode. Likewise, before opening, check it remains under inspection mode. Inspection box is provided with ropes for connection of all these safety elements, except for that of the speed governor in car, which is only supplied on request. In case some of these elements do not exist, fix the appropriate jumpers. In case of Macpuarsa complete lift, the slack-rope contact does not exist, so a jumper should be fixed in both cables.

V1.31,MAR.03

12 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.4.4. Speed governor remote control To facilitate speed governor tests, controller is provided with remote control with a 3-position switch and automatic return to OFF central position. It is actuated using a key. Turning the key clockwise enables operation signal and when turned anti-clockwise it enables reset signal. Should the speed governor not require reset signal, do not connect the corresponding terminal. The installer should decide which speed governor coil is actuated or reset in his installation. On request, the speed governor may be located inside the car instead of shaft. Wiring and electric schemes
Control panel wiring

220 Vp* FL (2A)

0 Vp*

OFF
Lower compartment Keyswitch located on raceway cover in lower compartment High rail

SALV

RL1 RL2 CRL

SALV

CHA_ CRL RL2 RL1

Shaft installation
CHA_ CRL Pink White RL2 Green RL1
Green RL1 White Pink RL2

L1 L2

XRLV

CRL

RL1 RL2 CRL

Blue Black Brown

CCA_ CRL RL2 RL1

CCA_ CRL RL2 RL1

Travelling cable
RL1 RL2 CRL

XRLV

RL1 RL2 CRL


SALV
L1 L2

Blue Black Brown

Inspection box In case of speed governor in car

* Remote control coil voltage may vary depending on order. The following table shows the expected operation of the speed governor remote control:
SALV TURNING DIRECTION CLOCKWISE ANTICLOCKWISE

FUNCTION INTERLOCK RESET

LIVE TERMINAL RL1 RL2

In Macpuarsa complete lift installations, do not connect RL2.

V1.31,MAR.03

13 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.4.5. VK-2P load weighing device All installations of this kind must have this load weighing device, so as to optimize the speed inverter features. Wiring and general scheme:

AL-C AL-S AUX

MENU
SERIE VK

MACPUARSA

Load weighing device VK-2P on car roof


EXC +

SENSOR

RS-485

AL-C 1 2 3

AL-S
Kg

VK-2P 220 Vac HOLD

6 5 +

MALLA

EXC -

+ IN

- IN

T1 T2

ConF=1 (Normally energized overload and complete relay) Note: the front side of connectors is here represented, but connection is carried out by turning these connectors. Connect gauges
D+ DINH INH 220 0Vp

MALLA -IN +IN EXC-EXC+

S6

S4 C3

C1

T2 T1

Car control station Plate on filter


CBC_
T1 T2

CBC_
T1 T2

Intermediate rail

MACPUARSA

+24 91 107

XPC

+24 91 107

CBC_
T2 T1

CBC_
T2 T1

DD+

XDSC

DD+

Control station travelling cable

(*)

CCS
216 107 91

CCS
216 107 91 91 107 216 91 107 216

Inspection box

Inspection box travelling cable


INH 220 INH 220 220 INH

CBS

CRA_

CCA_

CCA_

Lower compartment

(*) Optional connector, with MB-D display in control station only. For further information on load weighing device, see technical dossier Load Control System VK-2P .

V1.31,MAR.03

14 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.4.6. Encoder connection

* ENCODER WITH SHORT ROPE

ENCODER WITH LONG ROPE

Control panel

+ - C1+ C1- C2+ C2M-6 CENC

Control panel

+ - C1+ C1- C2+ C2M-6 CENC

H-6 H-6

+ -

C1+ C1- C2+ C2-

+ -

C1+ C1-C2+ C2-

Fixing mesh to controller with aluminium clamp and screw

Red Blue White Brown Pink Black

Connections to be done by the installer

Fixing mesh to controller with aluminium clamp and screw

Mesh

Mesh 3 metre rope 3 braided and screened pairs supplied by MACPUARSA

Stegmann HG-660 encoder rope

To encoder
C2- C2+ C1- C1+

- +

H-7 CENC'

M-7 CENC'
C2- C2+ C1- C1+

- +

Do not use

DETAIL

Connections to be done by the installer

Yellow

Brown

White

Black

Mesh

Blue

Pink

Red

Stegmann HG-660 encoder colours

Violet

Brown

White

To encoder

* The encoder connection must be carried out according to the rope length. Should it be a short rope, the cable supplied with the installation must be used. Should it be a long rope, (MACPUARSA lifts), it must be directly connected to the control panel.

V1.31,MAR.03

15 / 23

Black

Blue

Pink

Red

Connections to be done by the installer

+ -

C1+ C1- C2+ C2-

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.4.7. Machine supply

Lower compartment
211 212

- C1+C1- C2+ C2U V W t

Lower rail
EM1 EM2 TS1 TS2 0~ 220 206 204

Machine light earth fixing. According to 3VFMAC technical dossier, Chap. 10 EMC Requirements

Machine supply earth fixing. According to 3VFMAC technical dossier, Chap. 10 EMC Requirements

Encoder mesh earth fixing

211 212

- C1+ C1- C2+ C2-

Light on the machine (See point 3.4.5) Encoder (See point 3.4.7) Machine gear (See point 3.4.2)

TS1, TS2 Thermal probe 0~, 220 Ventilation 206, 204 Brake U, V, W + earth Machine supply

Machine connection box

V1.31,MAR.03

16 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

4.4.8. Shaft installation layout and wiring


CAH RB' CHA_ CH2 CHTF CH1 CC2

211 212 CA NOA NCA

TFN TFN

RL1 RL2 CRL

105 0Vdc 104 226 220 228

103

TFN TFN

+24

208

XRB

2 3
RL1 RL2 CRL

XLV XRLV
RL1 RL2 CRL

7 1

3 4 5 6 9

4 5*

XTL' XCT

6** 7
0 +24 228

XFS

XAFS

0 +24 228

8
9

CE1

BO

10

10

CEn

11 9 12
0 +24 226

XAFI

0 +24 226

13

11

XFI

12

XTL

13
Some connections are not shown in this scheme. Only connections that may guide a correct shaft installation are represented. ** Optional. * In case of double speed governor rope voltage contact. 1 Controller 2 String of lights 3 Speed governor contact 4 Speed governor remote control 5 Speed gov. rope voltage contact 6 Hatch contact 7 Upper final limit switch 8 Upper terminal stopping switch 9 External lock contact 10 Landing control station connector 11 Lower terminal stopping switch 12 Lower final limit switch 13 Tension pulley voltage contact 14 Pit box

211 212 CA NOA NCA

211 212 CA NOA NCA

14

TC SAHF

CAF

t 103 +24 208 TFN TFN

XCTS CFTF

STOPF

t 103 +24 208 TFN TFN

V1.31,MAR.03

17 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

5. OPTIONAL EQUIPMENTS 5.1. Emergency electric control unit Auxiliary box located in the cabinet upper compartment, which enables performing a rescue operation when energized. It may operate as the inspection box. It is inoperative when inspection box takes over control. NOTE: MES does bridge safety series; inspection control unit does not. Electric schemes

Lower compartment Emergency electric control unit box (M.E.S. box) Upper rail

11_ - CC1 111 - CC1 208 - CC2 0 Vdc PIN 103 8 - MBAS

11X/S 111/B RD 208 0Vdc 602 502 402

11X/S 111/B RD 208 0Vdc 602 502 402

MES

SIR'

STOP'

SIR' SPRB' SPRS'

MES box

SPRB'

SPRS'

1K5

SIR'

CRD

CRD

STOP'

SPRB'

SPRS'

Upper compartment
STOP SIR +24 Vdc SPRB 111/B-CB SPRS 11X/S-CB 208-CC2

Intermediate rail
RD 402 302 RD 402 302
STOP

SCTC

SEC1
SIR SPRB SPRS

Car installation
SEC2

CCA

CCA

SAF

Intermediate rail
SEM

Inspection box
STLH* SCTH STLH STOPF

302 202

302 202

Shaft installation

12 - MBAS

CHA

CHA

Pit box

In case of MES, you will find 2 wires marked with 11x CC1 and 111 CC1, which should be connected to the controller in the terminals corresponding to CC1 female connector, once the travelling cable is installed. 11x being the upper call.

Safety series. Special in installations with emergency electric control unit.

PCB MicroBASIC
110 Vs 15 FM RMT1 5 6

Machine room
SEM 12 EM1 EM2 202

STOPF STLH

Shaft
SCTH

Inspection box
STOP 302 SIR SPRS SPRB SAFC SEC1 SEC2 SCTC 402

STOP' A

MES box

*STLH

SIR'

PCB MicroBASIC
106

Car
SCC 105

Shaft
SCE 104

Shaft
SP 103

Shaft
SFI SFS SLVH 220 PIN 103 602 SLVC

Car
SAC 102 8 502

MES box

SPRB'

SPRS'

*In case of double speed governor voltage contact STLH inside the shaft.

V1.31,MAR.03

18 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

5.2. Terminal box This box, together with the necessary connectors, enables commissioning of the machine and may be used for the mechanical assembly of lift, so as to move the car upwards and downwards before performing the electrical installation. Controller should be powered and connected to the machine. Connectors should be plugged to the male connectors of the cabinet lower compartment, except for the connector located in the machine room connection box, where a jumper must be fixed between terminals EM1 and EM2, as shown in both figures. Finally, terminal box should be connected to the female connector from the set of connectors. There are two types of terminal box: 5.2.1. Without emergency electric control unit

CH2 H - 16

CC2 H - 16
t

103 t 228 220 226 104 0Vcc 105

t 220 102 208

105 106 220 S 208 B 102 H-5 M-5 220 S 208 B 102 t

30m 5x0.75 mm2 + t rope

CC1 H - 16

+24 120 119 118 117 116 115 114 113 112 111

STOP

Assembly control

(*)

Machine room connection box

EM1 EM2

Lower compartment

(*) Connect to last call.

V1.31,MAR.03

19 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

5.2.2. With emergency electric control unit

CH2 H - 16

CC2 H - 16
t

103 t 228 220 226 104 0Vcc 105

t 220 102 208

105 106 202 S 208 B 302 H-5 M-5 202 S 208 B 302 t
30m 5x0.75 mm2 + t rope

CC1 H - 16

MicroBASIC board

+24 120 119 118 117 116 115 114 113 112 111

STOP

Assembly control

(*)

302 202

EM1 EM2

RD 402 302
Lower compartment

(*) Connect to last call. Once this control is no longer necessary, disconnect all female parts shown in the figures and remove jumper EM1 and EM2. Then connect the rest of the electrical installation.

V1.31,MAR.03

20 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

5.3. Cabinet elevation system Optionally, a set of pieces is supplied enabling elevation of the electric cabinet in the shaft, using a hoist, for its location at the last floor. This assembly includes two plates, bracing the cabinet closing upper plate, and a DIN580 M12 ring and its corresponding nut, thus enabling attaching an appropriate sling. Assembly of this system on the electric cabinet is shown in the following figure.
DIN580 ring

Plate

Plate

Nut

The fixing hole of this assembly is protected with a rubber plug. Once the elevation operation is performed, this plug should be put back into place, as to avoid the entrance of dirt into the cabinet.

V1.31,MAR.03

21 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

ANNEX I. ABBREVIATIONS A
ARL BAT BTST CAA CAC CAH CAM CBC CC2 CCA_ CCS CENC CH2 CHA_ CLN COND CRD FA FAL FB FF FL FM FNA FNC FNH FP FS GRF GRL HAC HAM HRB HRB HA1/2/3 H-X K1 K2 KRET KRFR KRL KRL3 KRLE KRNS KRREV KRSE KSG MES M-X QAC QAH QASM Speed governor remote control key QF QIG RB RB RK RMT1 RVAR R1/2/3 SAC SAFC SALC SALH SALV SCC SCE SCM SCTC SCTH SEC1/2 SEM SFI SFS SHA1/2/3 SIR SIR SLVC SLVH SM SP SPRB SPRB' SPRS SPRS' STLH STOP STOP' STOPF S1/2/3 TC TCA TCC TCF TRM TS XFxx XHA1/2 3VFMAC Power thermomagnetic switch Control unit general switch

B
Battery Temperature probe

R
Connector of string of lights in shaft Connector of string of lights in car Rectifier of contactor K1 and K2 Live control unit relay Varistor Reactance

C
Cabinet lighting connector Car lighting connector Shaft lighting connector Machine lighting connector
Control station travelling cable auxiliary connector

S
Safety gear contact Slack-rope contact Car lighting switch Shaft lighting switch Speed governor remote control switch Car door lock series Landing door lock series Machineroomless lift Car hatch contact Shaft hatch contact Car interlock contact Machine gear contact Lower final limit switch contact Upper final limit switch contact Cabinet lighting microswitch Inspection switch Emergency electric control unit switch Speed governor contact in car Speed governor contact in shaft Machine room connection box Landing door presence series Inspection down pushbutton
Emergency electric control unit down pushbutton

Car travelling cable connector Car auxiliary connector Overload connector Encoder connector Shaft installation connector Shaft auxiliary connector Level indicator connector Capacitor Emergency electric control unit connector

F
Lighting differential Power supply Battery fuse Power differential Speed governor remote control fuse Control unit fuse Cabinet lighting screwed connector Car lighting screwed connector Shaft lighting screwed connector VK-2P load weighing device supply fuse Output filter

G
Brake rectifier board Cam rectifier board

Inspection up pushbutton
Emergency electric control unit up pushbutton

H
Car lighting Machine lighting String of lights in shaft String of lights on car roof Cabinet lighting X-pole female connector

Speed governor tension pulley contact Inspection box stop button Emergency electric control unit stop button Pit box stop button Starter

T
Power socket Cabinet power socket Car power socket Pit power socket Control unit transformer Thermal probe

K
Operation contactor Operation contactor Star-delta starting relay Brake relay Level relay Brake control relay (3VF) Cam relay Rated speed relay Inspection relay Direction relay Safety series relay

X
Cabinet fluorescent tube connector Cabinet lighting connectors Frequency inverter

M
Emergency electric control unit X-pole socket plug

Q
Car lighting thermomagnetic switch Shaft lighting thermomagnetic switch Machine room lighting thermomagnetic switch

V1.31,MAR.03

22 / 23

MIEPSCMUK

TECHNICAL DOSSIER
PRE-ASSEMBLED ELECTRICAL INSTALLATION FOR MACHINEROOMLESS LIFTS SCM

ANNEX II. DIFFERENCES BETWEEN VERSIONS 1.21, JUN.02 AND 1.31, MAR.03. Point 1: New powers 10CV - 230V and 15CV - 400V are included in the general features. Supply wiring requirements are included. Point 3.3: A supplement for closing the hole in case of door special height and an electric danger sticker to be put by the client are included. Point 4.2: Wiring is modified for the above-mentioned new powers. Point 4.4.1: Scheme is modified, including old point 3.4.5. Points 4.4.3 and 5.1: Scheme is modified, correcting the wiring, which was wrong. Point 4.4.8: Scheme is modified, including more connectors. Point 5.3: Instructions are included on the cabinet elevation system.

V1.31,MAR.03

23 / 23

MIEPSCMUK

VK - 2P Load Control System

Technical Dossier
v1.30, MAY 02 English / VK2PUk Installation Assembly Commissioning Use Maintenance Repair

TECHNICAL DOSSIER
VK-2P Load Control System

GENERAL TABLE OF CONTENTS


Chapter 1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . 1.1 Main Features of the VK - 2P Equipment . . . . . 1.2 Selection of the Load Cell . . . . . . . . . . . . . . . . 1.3 Description of the VK - 2P Equipment Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3 3

Chapter 2 DIMENSIONS AND DESCRIPTION OF THE WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.1 Dimensions and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.2 Description of the Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chapter 3 PROGRAMMING AND CALIBRATION 3.1 Access Keys to the Menu Parameters . . 3.2 Modification of a Parameter . . . . . . . . . 3.3 Programming Structure (Menus) . . . . . . 3.4 Equipment Calibration . . . . . . . . . . . . . 3.5 Alarms . . . . . . . . . . . . . . . . . . . . . . . . 3.6 Auxiliary Functions . . . . . . . . . . . . . . . 3.7 Rapid Programming Guide . . . . . . . . . . Chapter 4 ELECTRIC FEATURES 4.1 Electric Features . . . . . . 4.2 Change of Fuse . . . . . . . 4.3 Low-consumption Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5 5 6 7 7 7 8 8 8 8

Chapter 5 ERROR DISPLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Chapter 6 LOAD CELL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6.1 Load Cell TCMP + VK - 2P Installation Under the Car . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Chapter 7 LOAD INDICATOR FOR VK - 2P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 7.1 MB-D Car Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Chapter 8 DECLARATIONS OF CONFORMITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

v1.30, MAY 02

Page 2 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

Chapter 1 INTRODUCTION VK - 2P is a load control system for lifts and goods lifts. Its main function is immobilizing the car when it is overloaded or warning the control panel when the car is full, in order to avoid unnecessary stops. It has another function, that of indicating the load to a 3VFMAC frequency inverter, through a RS - 485 interface, to regulate the speed according to the load. In short, VK - 2P is not only a safety equipment, but it also contributes to comfort and rapidity in the service. There are three elements comprising the load control system: 1. Control equipment . . . . . (VK - 2P). 2. Load cell . . . . . . . . . . . . (Model TCMP). 3. Car display . . . . . . . . . . (Optional). 1.1 Main Features of the VK - 2P Equipment The main features of the VK - 2P weight controller include: Conditioning outputs for display in the car, 220Vac supply, inhibition input and chain compensation, communication RS - 485. 4-digit weight indicator. Supply capacity up to 16 cells, model TCMP 800. Load adjustment without introducing a known weight in the car. Two relay contact outputs. Complete load and overload alarm. Output for remote display (2 wires with no polarity).

1.2 Selection of the Load Cell TCMP 800 (load cell between frame and car) This measuring system is recommended for new lifts, since it is easy to install when assembling the car. It is very accurate (0.1% FULL SCALE), since the guides friction does not influence the load measure. Besides, it is the only system enabling speed regulation according to the load (operates with 3VFMAC). They can be supplied individually (requesting TCMP 800/I), or in groups of 4 pre-wired cells (requesting TCMP 800/G). This group of 4 pre-wired units is the basic configuration and enables measuring loads not exceeding 3.200 kg (Car weight + Useful load). Should it be necessary to measure higher loads (car weight + useful load is higher than 3.200 kg) individual cells or more groups of 4 cells may be added. Example: For lifts where the car weight + the useful load is lower than 4.800 kg a set of 4 cells besides 2 individual cells could be installed; should weight be lower than 6.400 Kg 2 groups of 4 could be installed. The maximum allowed is 16 cells TCMP 800 or 4 groups of 4 pre-wired cells TCMP 800. In case of a malfunction in any cell of the pre-wired group (TCMP 800/G), cut the rope joining it to the group, replace with an individual cell and then connect as shown in page 10 of this Technical Dossier. 1.3 Description of the VK - 2P Equipment Operation VK - 2P is an electronic equipment that obtains the weight of the car, processing the signal received from a load cell and then informs the 3VFMAC frequency inverter about this weight, every time it requests it, thus changing the state of the output relays, when the load exceeds the values programmed for each function. Relays inform of complete lift and overloaded lift.

v1.30, MAY 02

Page 3 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

Chapter 2 DIMENSIONS AND DESCRIPTION OF THE WIRING 2.1 Dimensions and Wiring
153 11 3.5 139

AL-C AL-S AUX.

MENU

SERIE VK

35

72 1 AL-C 3 2 4 AL-S 6 5
kg.

42

SENSOR EXC.+ EXC.+IN -IN MALLA

RS-485

VK-2P 220 ~ HOLD

T1

T2

41

Red Black Green White Mesh

Overload

RS-485
Complete Mains

Inhibition Voltage 24 - 220 Vac / Vdc

Relay output

kg.

Car Display

Load Cell

2.2 Description of the Wiring AL - C (Complete Relay) Should the load programmed in parameter AL - C be exceeded, its state changes. AL - S (Overload relay) Should the load programmed in parameter AL - S be exceeded, its state changes. The quiescent state of the relays can be modified in parameter ConF . RS - 485 (2-wire communication) The car weight is transmitted to the 3VFMAC equipment through it. HOLD (Enabled with either alternating or direct voltage between 24V and 220V). When the lift is in operation, the weight measurement is not accurate, relays could be enabled and the car display could be unstable. Enabling the HOLD input when the lift starts operating, the weight measurement is blocked, the display blinks and relays as well as the car display keep their state until this input is disabled, after the lift stops. Car Display Output There are two types of output, which can be selected with parameter ConF : a) Output energized in a flashing way, when overload occurs. The output has a polarity and can be valid to enable a led and a buzzer (direct current 7,5V max.75mA). b) MB-D progressive display enabling (two-wire connection with no polarity).

v1.30, MAY 02

Page 4 / 13

VK2PUK

86

MACPUARSA

TECHNICAL DOSSIER
VK-2P Load Control System

v1.30, MAY 02

Page 5 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

Chapter 3 PROGRAMMING AND CALIBRATION 3.1 Access Keys to the Menu Parameters The equipment has a menu to access the adjustment parameters.

By pressing this key successively, all programmable parameters are displayed in a cyclic way. To go back to the weight display, press this key until getting to the end of the menus. Press for 2 seconds. When a specific parameter is displayed, press this key in order to modify it.

When a specific parameter is shown, pressing this key the display shows its content.

3.2 Modification of a Parameter 1) 2) 3) 4) Press the MENU key successively until the desired parameter is displayed. Press the key to go to the parameter modification option; the left digit will be blinking. Introduce the desired value in the display using the keys. Press MENU twice.

When pressed for the first time, the value is introduced and the display is blinking for 10 seconds. The second time the operation is confirmed. 1) If MENU is not pressed for a second time, before intermittency ends, the operation is not stored and the display shows the parameter again. 2) In order to modify parameters PESO and CEro , see point 3.4 (Equipment Calibration). 3.3 Programming Structure (Menus) Weight Display

Complete alarm Overload alarm Reset adjustment Adjustment with known weight Adjustment with direct load cells Car weight compensation Car display and relay state configuration

v1.30, MAY 02

Page 6 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

3.4 Equipment Calibration This section is necessary in order for the equipment to know the relation between the cell signal and the weight introduced in the car. There are to ways of calibrating the equipment : I) Standard Calibration (suitable for all types of cells). 1) Reset : a) b) Go to the menu option CEro . Make sure the car is empty and press the key. Then press MENU , while the display is flashing, to confirm the reset. The operation starts with a countdown and then, the display will show parameter PESO. If MENU is not pressed before intermittency ends, the operation is not stored and the display shows parameter CERO again.

2)

Weight Adjustment : a) b) Go to the menu option PESO . Introduce a known weight inside the car and press

The weight should be at least 50% of the maximum. c) d) Introduce the value of the weight placed inside the car with keys . To save the value press MENU twice (the value is stored). The display will then show the following adjustment parameter: CELL . If MENU is not pressed for the second time before intermittency ends, the operation is not stored and the display will show parameter PESO again. II ) Calibration for cells between frame and car (model TCMP). It is not necessary to introduce a known weight in the car, in order to carry out this operation. 1) 2) Reset (as in standard calibration). Weight Adjustment : a) b) c) Go to the menu option CELL . Press to access and assign the value. Introduce the value of the cell load with keys

This information is shown in the cable end, and corresponds to the factory calibration value. d) Press the MENU key twice in order to save the value (the value is stored). The display will then show the following adjustment parameter: CADE . If MENU is not pressed for a second time before intermittency ends, the operation is not stored, and the display will show parameter CELL again.

v1.30, MAY 02

Page 7 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

3.5 Alarms Alarms are the load levels in which the state of relays changes. In order to adjust them no weight is necessary; just programme them with the keyboard. Load value from which the lift is complete. When the load in the lift exceeds that value, the complete relays state changes and the MB-D car display will switch on up to the head.

Load value from which the lift is overloaded. When the load in the lift surpasses that value, the overload relays state changes and the MB-D car display will indicate, both visually and acoustically, that the lift is overloaded. In the case a led is connected to a display output, it will intermittently switch on. See point 3.2 (Modification of a Parameter) for details about the alarm adjustment. 3.6 Auxiliary Functions Configuration ConF = 0 ConF = 1 ConF = 2 ConF = 3 3.7 Rapid Programming Guide This section describes how to configure rapidly the most important parameters of the equipment. a) b) c) d) Press MENU successively to search the parameter to be modified and press Modify using . to access this parameter. Relay State ON ON OFF OFF Display Output Intermittent Enabling ( LED ) Progressive Enabling ( MB-D ) Intermittent Enabling ( LED ) Progressive Enabling ( MB-D )

To save, press MENU twice. The most important parameters to be configured: : 1. Introduce in AL C the load value from which the activation of the complete alarm is required. 2. Introduce in AL S the load value from which the activation of the overload alarm is required. 3. Reset the equipment with the lift empty : Go to parameter CEro Press MENU and a countdown starts. 4. Adjust the weight : Put a weight in the car (at least 50% of the maximum weight) Introduce the value of the load put in the car in PESO . The equipment starts a countdown. It is important to make the zero adjustment before the weight adjustment operation

v1.30, MAY 02

Page 8 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

Chapter 4 ELECTRIC FEATURES 4.1 Electric Features Model : . . . . . Rated voltage : Rated current : Rated frequency Fuse : . . . . . . . .. .. .. : .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VK - 2P. 220V. 60 mA. 50 - 60 Hz. 100 mA.

4.2 Change of Fuse 1) 2) 3) Disconnect the equipment. Open the equipment by removing the 5 screws holding the back cover. Get the circuit out of the box and change the fuse installed in a vertical bayonet fuse carrier, next to the transformer.

4.3 Low-consumption Mode Since the display is the element which consumes the most and it is not visible, a low-consumption mode has been taken into consideration in which the display turns off showing a rotary segment to indicate it is still operative. Cases where the equipment starts operating under the low-consumption function. 1) When connected to the mains, the equipment displays the weight for 3 minutes and in the case no key is touched, it automatically operates under low-consumption mode. When an hour has passed since the last time a key was touched. When the equipment displays the weight while pressing the key for two seconds. Press any key to exit the low-consumption function.

2) 3)

v1.30, MAY 02

Page 9 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

Chapter 5 ERROR DISPLAY Err1 Load cell wrongly connected, damaged or fractured rope. Err2 Check cell connection.

Negative flooding. The load cell is operating in the opposite direction or is wrongly connected.

Err3

Positive flooding, the load cell is bearing a weight higher than the rated value. It is necessary to put a load cell with a higher rated value.

Err4

Polarity error. (This error is detected when the equipment adjusts the weight with the polarity of the modified cell). Check cell connection. Make the zero and weight adjustment again.

Err5

Output for short-circuited car display (figure of a person). Locate and remove the short circuit. Turn off the equipment (VK) and then turn it on again so that Err5 no longer exists in the display.

Err6

Data loss in the memory. All parameters shall be programmed again.

1) 2)

When an error occurs, all alarms are enabled and the lift is blocked. When Err5 occurs, the equipment is blocked and it does not transmit information via the communications port, until the short circuit is removed.

v1.30, MAY 02

Page 10 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

Chapter 6 LOAD CELL INSTALLATION 6.1 Load Cell TCMP + VK - 2P Installation Under the Car This configuration weighs the car directly, so the guides friction errors are removed. Cells may be supplied individually (requesting TCMP 800/I), or in groups of 4 pre-wired cells (requesting TCMP 800/G). This group of 4 pre-wired units is the basic configuration and enables measuring loads not exceeding 3.200 kg (Car weight + Useful load). Should it be necessary to measure higher loads (car weight + useful load is higher than 3.200 kg) individual cells or more groups of 4 cells may be added. Example: For lifts where the car weight + the useful load is lower than 4.800 kg a set of 4 cells besides 2 individual cells could be installed; should weight be lower than 6.400 Kg 2 groups of 4 could be installed. The maximum allowed is 16 cells TCMP 800 or 4 groups of 4 pre-wired cells TCMP 800. In case of a malfunction in any cell of the pre-wired group (TCMP 800/G), cut the rope joining it to the group, replace with an individual cell and connect as shown in this Technical Dossier.

TCMP 800/G

ELECTRICAL CONNECTION Excitation ( + ) Excitation ( - ) ( + ) IN TCMP 800/I ( - ) IN Red Black Green White
CAR

134 128
Cable length 5 m

31 M - 10
Load cell TCMP

Elastic plug

28

48

160 190 13

44

46

Cells may be installed either with the base supported on the bedframe and the intermediate point in contact with the car or inverted.

TCMP 800 DIMENSIONS

Cable length 1.5 m

800 kg. 1 2

800 kg.

Cable length 5m

800 kg. 3 4

800 kg.

SET OF 4 PRE-WIRED CELLS

v1.30, MAY 02

Page 11 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

Chapter 7 LOAD INDICATOR FOR VK - 2P 7.1 MB-D Car Display Progressive display. It has a figure of a person which progressively illuminates according to the weight. When it reaches the Complete level, the figure will be completely illuminated. When it reaches the Overload level, the figure will flicker and the buzzer will be enabled. This car indicator, model MB-D, is an accessory installed inside the car.

73.00 67.00 54.00


+0 -0.1

19 12.5 2

40.00

+0 -0.1

76.00

29.50

4(4Tls.)

65.50

5 8

2-wire connection with no parity (series VK)

FRONT VIEW

REAR VIEW

v1.30, MAY 02

Page 12 / 13

VK2PUK

TECHNICAL DOSSIER
VK-2P Load Control System

Chapter 8 DECLARATIONS OF CONFORMITY EC declaration of conformity to directive 89 / 336 / EEC regarding electromagnetic compatibility. EC declaration of conformity to directive 73 / 23 / EEC of low voltage.