MINI-SPLIT ERROR CODES

Error Code E1 High Pressure protect Explanation R Y G 1 Notes Explanation It is a sensor put aside the exhaust pipe.Once the pressure of exhaust pipe surpass 3.15Mpa, the airconditioning system will stop working. Sensor on the indoor unit dects the evaporator temperature continuously, once the temperature is lower than some point for certain time, it will turn off the system to avoid freezing the indoorunit. For system with low pressure sensor(locating aside the inspiration pipe), once the pipe's pressure is lower than 0.15Mpa, the system will stop working. 6 sec Pause before Flash Sequence Once the exhaust temperature of the compressor is higher than regulated, the system will be turned off automatically.

E2 Inside Anti-Freeze Protect

E3 Low Pressure Protect

E4

Compressor Discharge protect low pressure over current protect indoor-outdoor communication Error

E5

Once the system current is higher than regulated,the system stops. Bad communication between indoor and outdoor units.

E6

E7 Mode conflict

For multi split airconditioners,when one of the indoors is working for cooling(dehumidifying),other indoor unit can no work for heating. While heating, indoor tube temperature sensor will detec While heating, the indoor fan will work several minutes later than the compressor so that the airflow comes out the airconditioner will not be too cold. For invertor system, the frequecy will lower down when the voltage drop sharply, so that the current can keep stable.

E8 E9

high Temp protect

8 9

cold wind protect

E0

AC Voltage Low No Indoor motor feedback room temp sensor open/short

10

H6

11

F1

Temperature sensor defect inspection.

F2

Indoor evaporator sensor open/short Outdoor temp sensor open/short Outdoor evaporator sensor open/short Outdoor sensor open/short

F3

F4

6 sec Pause before Flash Sequence

F5

F6 Cooling Overload

For invertor, while cooling, the outdoor tube temperature sensor detect the tempearture continuously, and will low the working frequency if the tube temperature is higher than some point for certain time. For invertors only.After a period of cooling, the system will work in higher frequecy for a period. For invertors only. Lower the freqecy, reduce the load if the current is higher than standard. For invertors only. Lower frequecny, if exhaust temperature is higher than standard.

F7

Unused

F8

Current Overlaod

F9

Unused Unused Defrost Static duct clean protect compressor overload protect

F0 H1

10 1 In heating condition, defrosting auotmatically and keep the heat exchange efficeincy.

H2

H3

Compressor stop working when the compressor temperature is higher than regulated. While cooling, system stops if the outdoor tube temperature is higher than a certain point for certain time. While heating, system stops if the indoor tube temperature is higher than a certain point for certain time. For invertors only.

H4 System Abnormal

H5 H6

Mode Protect

5 6 6 sec Pause before Flash Sequence 7 8

Unused

H7 H8

Synchronize fail

Water full protect

For system with water pump,such as cassette airconditiners, the system stop working when the water level surpassed regulated level.

H9 HO

heating Error Heat high temp protect Pipe Hot

9 10 For invertors only. While heating, lower the frequency if the indoor tube temperature is higher than standard. For invertors only.While cooling, lower the frequency if the outdoor tube temperatuer is higher than standard. For invertors only. While cooling, lower frequency if the indoor tube tempearture is lower than standard.

FA

FH

Freeze Protect