CAT RD Technical Specifications

ADJUSTMENT INSTRUCTION NSP16N(I) dACi-HCU

1 /2

CAT HCU
65_10949

Rev. Pvm.

E 28.6.2007

NSP16N side stab.

NSP16NI

NSP16N

D=Diagnostics

dACi- HCU

dACi- HCU

dACi- HCU

Parameter number

Valid in BPK

Range/value

NOTE

Date Serial number Download version Iset lift/lower Act. Iset li/lo Act. function Operating cond Set poti pv1 Set poti pv2 Battery voltage Valve current 0 Valve current 1 input open Analogue-out 0 Analogue-out 1 Dig_input Check dig-output Min. current prop. valve 1 Max. current prop. valve 1 Acc. ramp prop. valve 1 Dec. ramp prop. valve 1 set value current PV1 at OnOff-Lift set value current PV1 at OnOff-Lower Acc. ramp PV1 at OnOff-Lift/Lower Dec. ramp PV1 at OnOff-Lift/Lower set value current PV1 at Initial-Lift set value current PV1 at Initial-Lower Acc. ramp PV1 at Initial-Lift/Lower Dec. ramp PV1 at Initial-Lift/Lower delay time between Pumpe=ON and control of Valve delay time between Pumpe=OFF and Valves=OFF Delay time after initial-Lift = OFF Delay time after initial-Lift = ON selection hydraulic configuration use enable input set value current PV1 at stabilizer-lift ser value current PV1 at stabilizer-lower delay time after stabilizer-lift = OFF delay time after stabilizer-lift = ON delay time after stabilizer-lower = OFF delay time after stabilizer-lower = ON Nom. battery voltage Teach-In poti values

0 7 8 10 11 20 25 30 31 32 34 35 37 38 39 40 42 84 85 86 87 90 91 92 93 95 96 97 98 120 121 123 124 125 126 130 131 132 133 134 135 172 251

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

D D D D D D D D D D D D D D D D D 200 650 1000 5000 0 500 5000 5000 200 350 1000 4000 250 500 0 100 0 0 500 450 0 100 0 100 D 0

D D D D D D D D D D D D D D D D D 200 650 1000 5000 0 500 5000 5000 200 350 1000 4000 250 500 0 100 0 0 500 450 0 100 0 100 D 0 2 1 500 450 0 100 0 100

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0-2000 mA 0-2000 mA 0-10000 mA/s 0-10000 mA/s 0-2000 mA 0-2000 mA 0-10000 mA/s 0-10000 mA/s 0-2000 mA 0-2000 mA 0-10000 mA/s 0-10000 mA/s 0 0 0 0 0 = initial lift, 1 = on/off lift, 2 = lift/lower side stabilizers 0 = disabled (no lift limit) 1 = enabled (lift limit) 0-2000 mA 0-2000 mA 0-2000 ms 0-2000 ms 0-2000 ms 0-2000 ms V 0

NOTE: Parameter 125 must be adjusted according to the truck application, otherwise errorcode 11 will be displayed and HCU disabled.

HCU BPK Access

CAT RD Technical Specifications

Connectors and Error codes NSP16N(I) dACi-HCU

2/2

CAT HCU

Rev. Pvm.

E 28.6.2007

Pin description

Status shown in BPK

Error code (nr.of pulses)

Pin number

Connector X1

Connector X2

Connector X3

Connector X7

1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4

Key Input 0V Proportional valve 2 + Proportional valve 1 + Proportional valve 1 Proportional valve 2 Contactor + Valve 1 + Valve 2 + Valve 3 + Valve 4 + Valve 5 + Contactor Valve 1 Valve 2 Valve 3 Valve 4 Valve 5 +24V Dig-input 1 Dig-input 2 Dig-input 3 An-input 1 + An-input 1 An-input 2 0V Dig-input 4 Dig-input 5 Dig-input 6 An-input 1 An-input 2 + An-input 2 +15V 0V A B

New Software version Runtime monitoring Low Voltage Battery Runtime monitoring Over Voltage Battery Runtime monitoring parameters of set value curve lift/lower not realistic

parameters of set value curve option not realistic

more than one functions choosen (more than one inputs at the same time switched on) error in sequential program (internal error)

10

11

Digital output error Runtime monitoring Hydraulic pots range Lift / Lower potentiometer exceeds it's range EEPROM Fault Runtime monitoring

12

14

Connectors and Errorcodes

Error description