INSTALLATION SPECIFICATIONS
13"
Minimum Tank Access
21"
42"
FRONT
LEFT SIDE
Electrical . . . . . . . . . . . . . . . . 208 VAC Single phase 2.8kVA (15A) . . . . . . . . . . . . . . . . 220 VAC Single phase 2.9kVA (14A) . . . . . . . . . . . . . . . . 230 VAC Single phase 3.1kVA (14A) . . . . . . . . . . . . . . . . 240 VAC Single phase 3.3kVA (14A) Note: 2 wire feed plus separate ground wire. Sensible heat loss . . . . . . . . . . 6,390 @ 208 VAC ~ 6,890 @ 240 VAC B.t.u./hour Operating weight . . . . . . . . . . 550 Lbs. External dimensions . . . . . . . 42" L x 21" W x 50" H Note: Needs a minimum opening of 22" to move through a door or passage Cooling water . . . . . . . . . . . . . gallon per minute Note: Cooling water not used when room temperature kept at or below 850 F.
BACK
Page 1 of 3
FILM PATH
Film Sensor Film Cutter Film (in cradle)
PROCESS SPECIFICATIONS
C-41RANP Processing tank capacities (liters) Operating temperature (Fahrenheit) Time per step (seconds) Replenisher tank capacities (liters) Water replenisher tank (liters) Waste tank capacities (liters) Page 2 of 3 CD 7.6 100 0.25 195 12 3.3 BL 3.1 95~105 69 12 5.0 8.8 FIX 5.4 (2 tanks) 95~105 136 12 STB 5.7 (3 tanks) 95~105 122 12 DRY 122 ~ 158 122
Cut out and use with a scaled drawing (" = 1') of your floor plan to determine the best location for the equipment.
QSF-V30
" = 1'
20" Note: Dimensions and shaded area indicates minimum clearance to walls, other equipment, etc. Additional clearance is suggested on all sides (except side to the left of the operator's position) and may be required by local codes.
Power Connection (under control cabinet) Operator Position
4"
Note:
Cooling water not used when room temperature kept at or below 850F.
Page 3 of 3
21"
42"
FRONT
LEFT SIDE
Electrical . . . . . . . . . . . . . . . . . 208 VAC Single phase 3.0kVA (15A) . . . . . . . . . . . . . . . . . 220 VAC Single phase 3.0kVA (14A) . . . . . . . . . . . . . . . . . 230 VAC Single phase 3.2kVA (14A) . . . . . . . . . . . . . . . . . 240 VAC Single phase 3.4kVA (14A) Note: 2 wire feed plus separate ground wire. Sensible heat loss . . . . . . . . . . 6,390 @ 208 VAC ~ 6,890 @ 240 VAC B.t.u./hour Operating weight . . . . . . . . . . 495 Lbs. External dimensions . . . . . . . . 42" L x 21" W x 50" H Note: Needs a minimum opening of 22" to move through a door or passage Cooling water . . . . . . . . . . . . . gallon per minute Note: Cooling water not used when room temperature kept at or below 850 F.
BACK
Page 1 of 3
FILM PATH
Film Sensor Film Cutter Film (in cradle)
PROCESS SPECIFICATIONS
C-41SM Processing tank capacities (liters) Operating temperature (Fahrenheit) Time per step (seconds) Water replenisher tank (liters) Waste tank capacities (liters) CD 4.1 100 0.25 195 2.4 BL 2.2 95~105 69 5.0 0.9 4.3 4.5 FIX 3.5 (2 tanks) 95~105 136 STB 4.3 (3 tanks) 95~105 122 DRY 122 ~ 158 122
Page 2 of 3
Cut out and use with a scaled drawing (" = 1') of your floor plan to determine the best location for the equipment.
QSF-V30SM
" = 1'
20" Note: Dimensions and shaded area indicates minimum clearance to walls, other equipment, etc. Additional clearance is suggested on all sides (except side to the left of the operator's position) and may be required by local codes.
(through bottom of control cabinet)
4"
Power Connection
Operator Position
Note:
Cooling water not used when room temperature kept at or below 850F.
Page 3 of 3