You are on page 1of 40

A chiller as unique as your needs.

YORK Model YVAA Air-Cooled Chillers


Variable Speed Screw, 150-500tons

Johnson Controls

Contents
Customer Value Proposition
Duration: 20 minutes

Technology
Duration: 20 minutes

Competition
Duration: 20 minutes

Handling Customer Needs


Duration: 20 minutes

Selling Tools
Duration: 20 minutes

Questions and Answers


Duration: 20 minutes

Value Proposition
Duration: 20 minutes

Johnson Controls

YVAA YORK Variable Speed Air-Cooled Screw Chillers

YORK A History of Leadership and Innovation


The global market leader in Variable Speed Drive chillers with 30 years of experience varying compressor motor speeds

YVAA YORK Variable Speed Air-Cooled Screw Chillers

Key Benefits

Efficiency

Sustainability

Low Sound

Confidence

Model YVAA YORK Variable Speed Air-Cooled Screw Chillers

Overview
A Chiller As Unique As Your Needs
Tailor and tune chiller configuration to specific job requirements Match performance to your design point An industry leader in efficiency and technology

Model YVAA YORK Variable Speed Air-Cooled Screw Chillers

Overview
Key technology elements of the system
Heat Exchangers high efficiency falling-film evaporator & advanced microchannel condenser coil designs
Controls leveraging YORK and Johnson Controls technology & know-how Variable Speed Drive compressor VSD from the industry pioneer, and condenser fan VSD to maximize performance Screw Compressors proven, industry-leading screw compressor design with more than 15,000 VSD compressors operating worldwide

Efficiency
Intelligent cost reduction, flexible energy consumption

Efficiency
Intelligent cost reduction, flexible energy consumption Industrys Lowest Energy Consumption at Design Conditions
When desired, YVAA chillers can be offered at up to 11.6 EER 20% Improvement over current ASHRAE 90.1 minimum

Ordinary Chiller YVAA

Industrys Lowest Energy Consumption at Off-design Conditions


When desired YVAA chillers can be offered up to 19.8 IPLV EER

Johnson Controls

Efficiency
Intelligent cost reduction, flexible energy consumption YVAA chiller saves 25% to 50% in annual energy costs For new or replacement installations, the YVAA offers significant savings

10

Johnson Controls

Efficiency
Intelligent cost reduction, flexible energy consumption Easily qualify for rebates based on VSD usage Standard high power factor can earn rebate without added cost Tailor & tune your YVAA chiller to qualify for any Performance Rebate

11

Johnson Controls

Sustainability
Giant step forward, smaller footprint

Sustainability
Giant step forward, smaller footprint Indirect Emissions Contribute 98% of Chiller GWP
Electricity generation is the largest source of greenhouse gas emissions Efficiency of YVAA chiller offers substantial reduction in power consumption & your environmental footprint

Direct Emissions Contribute 2% of Chiller GWP


HFC-134a refrigerant has ZERO ozone-depletion potential and no phase-out date Falling-film evaporator reduces refrigerant charge by up to 15%

Water Consumption
Power generation can deplete water resources An indirect benefit of the YVAA chiller: water conservation Gain the efficiency of a water-cooled chiller for the cost of an air-cooled
13 Johnson Controls

Sustainability
Giant step forward, smaller footprint Helps You Achieve LEED Certification
Enhanced Refrigerant Management: Low refrigerant use ensures 2 points for Energy and Atmosphere Credit 4 (EAc4) Optimize Energy Performance: Higher efficiency helps your building qualify for maximum points for the Energy and Atmosphere Credit 1 (EAc1)

14

Johnson Controls

Low Sound
Lower the volume, increase goodwill

Low Sound
Lower the volume, increase goodwill Off-Design Conditions Occur 99% of the Time
Most stringent sound requirements occur on evenings and weekends
Ordinary Chiller YVAA YVAA Optimized YVAA Optimized with Attenuation Options

Standard VSD compressors designed for sound relief a reduced speeds


Optional VSD condenser fans will provide further significant off-design sound benefit Further accessories can provide sound reduction at on-design conditions

16

Johnson Controls

Low Sound
Lower the volume, increase goodwill Sound Level That You Can Control
Our proprietary SilentNight technology automatically integrates with your BAS (or programmable) control to load shed BAS of load shedding provides Night Set-Back for the neighborhood Effective when regulations require more stringent property line sound levels at night
Ordinary Chiller YVAA YVAA Optimized YVAA Optimized with Attenuation Options

-10

17

Johnson Controls

Low Sound
Lower the volume, increase goodwill For the Other 1% at Design Conditions:
Property line restrictions will require attention to (worst case) design conditions sound levels Just like performance, the YVAA chiller allows you to tailor and tune sound reduction configurations to match your needs

18

Johnson Controls

Confidence
Confidence-driven, performance-proven

Confidence
Confidence-driven, performance-proven Proven by Experience
Over 2 Million tons of VSD, air-cooled screw chillers operating globally

All units combined, more than 18,000 years of cumulative field experience

Capacity: In Tons
> 50,000 10,000 50,000 5,000 10,000 1 5,000

Confidence
Confidence-driven, performance-proven Compressor & VSD
More than 15,000 compressors operating on VSD in air-cooled chiller applications

Eliminates slide valve and associated inefficiencies, and reduces compressor moving parts by 50%

Reliable by Design
1 Circuit per compressor built-in redundancy
Soft start standard no current inrush

21

Johnson Controls

Confidence
Confidence-driven, performance-proven Proven Support
15,000+ Service Technicians (trucks on road) in 150 countries Service Technicians trained on VSD screws since 2004 Bringing decades of VSD experience to your door

22

Johnson Controls

YVAA YORK Variable Speed Air-Cooled Screw Chillers

Key Benefits

Efficiency

Sustainability

Low Sound

Confidence

23

YVAA YORK Variable Speed Air-Cooled Screw Chillers

Smart, sustainable, silent and specified the world over.


Reduce your annual energy costs by as much as 50% Reduce your sound by up to 16dBA to meet tighter regulations

Minimize your environmental impact dramatically


Improve your peace of mind knowing we stand behind every chiller

24

Technology
Duration: 20 minutes

25

Johnson Controls

YVAA Cycle Diagram

26

Johnson Controls

YVAA Cycle Diagram

27

Johnson Controls

YVAA Cycle Diagram

28

Johnson Controls

Variable Speed Drive


Delivering best in class performance at real world conditions Higher efficiency at part load Lower sound at part load

Ordinary Chiller YVAA

Ordinary Chiller YVAA YVAA Optimized


YVAA Optimized with Attenuation Options

-10

29

Johnson Controls

Variable Speed Drive


Improves payback with lower electrical costs and rebates
VSD provides Soft start with no inrush: Starting current never exceeds full load amps.
Lowest maximum electricity demand costs Eliminates compressor starting thermal and electrical stress No motor heating at start allows for quicker restart after power failure Stand by generator size reduced High (95%) displacement power factor

The VSD in YVAA provides 0.95 displacement power factor as standard.


Qualifies for rebates from electrical utility companies, which contributes to payback.

30

Johnson Controls

Variable Speed Compressor


Reliability through simplicity
Proven reliable compressor 52% fewer moving parts 35% fewer leak points Automated machining of rotors

High precision 4 microns Frick design and manufacture

31

Johnson Controls

Evaporator Technology
DX Evaporator: Water outside the tubes Refrigerant inside the tubes Water connection at sides Flooded Evaporator: Water inside the tubes Refrigerant outside the tubes Water connection at ends

32

Johnson Controls

Falling Film Evaporator


Incorporates best elements of the DX and Flooded styles Hybrid Falling Film Evaporator:
Water is inside the tubes; Refrigerant is outside the tubes Two bundles of water tubes Upper bundle is covered in a film of refrigerant Lower bundle is flooded in the refrigerant

HIGH LOW

Efficiency

Falling Flooded Film DX LOW HIGH Refrigerant Qty

33

Johnson Controls

Micro Channel Condenser Coils


Lightweight, robust and easily cleaned All Aluminum tubes, fins, and headers
Better heat transfer per volume of coil

Images courtesy

34

Johnson Controls

Micro Channel Condenser Coils


Lightweight, robust and easily cleaned
Lighter weight of aluminum lowers the overall chiller weight: Save costs of roof reinforcements and lifting equipment Reduces the amount of refrigerant used. The quantity of R134a used in the chiller allows to qualify for 2 LEED EAc4 points

35

Johnson Controls

Micro Channel Condenser Coils


Lightweight, robust and easily cleaned
All aluminum construction minimizes the opportunity for galvanic (dissimilar metal corrosion Increases the chiller life and limits the degradation of performance over time The fins do not extend past the tubes making it easier to clean with water spray without bending the fins. Microchannel coils are less deep, allowing complete washing without dirt being trapped inside the coils

36

Johnson Controls

Competition
Duration: 20 minutes

37

Johnson Controls

Most efficient air-cooled screw chiller in market Comparison at Full Load


Efficiency levels 5% to 20% higher than ASHRAE 90.1 2010 Models up to 14% more efficient than market average at full loads
Premium Efficiency

High Efficiency

Standard Efficiency

38

Johnson Controls

Most efficient air-cooled screw chiller in market Comparison at Part Load


Efficiency levels 35% to 55% higher than ASHRAE 90.1 2010 Models up to 33% more efficient than market average at part loads
YVAA Range

Staged Fans data to be added

39

Johnson Controls

Lowest MCA in market


MCA: Minimum Circuit Ampacity

Lower electrical costs For replacement opportunities, allows to increase capacity without forcing to upsize the existing electrical connections

40

Johnson Controls

You might also like