You are on page 1of 50

Prepared by:

Bodie McDaniel

Prepared for:

Talland Navigation

Date:

19 Feb 2013

Project:

N527

CONTENTS
Bostrig 125 Type P Control 10&12AWG

................................................................................................................
1

Bostrig 125 Type P Control 12&10AWG

................................................................................................................
3

Bostrig 125 Type P Control 14AWG

......................................................................................................................
5

Bostrig 125 Type P Control 16AWG

......................................................................................................................
7

Bostrig 125 Type P Control 16AWG AS


Bostrig 125 Type P Control 18AWG

......................................................................................................................
11

Bostrig 125 Type P Control 18AWG AS


Bostrig 125 Type P Power 2C

.................................................................................................................
9

.................................................................................................................
13

............................................................................................................................
15

Bostrig 125 Type P Power 2C AS

..........................................................................................................................
17

Bostrig 125 Type P Power 3C AS

..........................................................................................................................
19

Bostrig 125 Type P Power 4C

............................................................................................................................
21

Bostrig 125 Type P Power 4C AS


Bostrig 125 Type P Power 5C

..........................................................................................................................
23

............................................................................................................................
25

Bostrig 125 Type P Power 5C AS

..........................................................................................................................
27

Bostrig 125 Type P Signal Cable

...........................................................................................................................
29

Bostrig 125 Type P Signal Cable

...........................................................................................................................
31

Bostrig 125 Type P Signal IO P 16&14AWG

.........................................................................................................
33

Bostrig 125 Type P Signal IO P 16&14AWG AS


Bostrig 125 Type P Signal IO P 20&18AWG

.........................................................................................................
37

Bostrig 125 Type P Signal IO P 20&18AWG AS


Bostrig 125 Type P Signal IO T 18&16AWG

....................................................................................................
39

..........................................................................................................
41

Bostrig 125 Type P Signal IO T 18&16AWG AS


Bostrig 125 Type P VFD 2kV

....................................................................................................
35

....................................................................................................
43

............................................................................................................................
45

II

CONTENTS

This catalog represents only a partial selection of Draka Marine, Oil & Gas International wire
and cable products, based on criteria submitted when requesting the information. For a
complete list of Draka Marine, Oil & Gas International products, including specialty conversion
and termination items, visit www.DrakaMOG.com.
All products are subject to current availability. Please check with your Draka Marine, Oil & Gas
International representative.

All contents 2007 Draka Marine, Oil & Gas International. All rights reserved.

III

Bostrig Type P
0807
Page 17 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed

TYPE P CONTROL CABLE


600V or 0.6/1kV
12 & 10 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

www.DrakaMOG.com

Bostrig Type P
0807
Page 18 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV


multi-conductor / armored and sheathed
12 & 10 AWG / 600V or 0.6/1kV
12 AWG 3.08 mm2
Type
Designation
C12PNBS-2
C12PNBS-3
C12PNBS-4
C12PNBS-5
C12PNBS-6
C12PNBS-7
C12PNBS-8
C12PNBS-10
C12PNBS-12
C12PNBS-16
C12PNBS-20
C12PNBS-24
C12PNBS-30
C12PNBS-37
C12PNBS-44
C12PNBS-60
C12PNBS-91

Draka
Number
026300
026301
026302
026303
026304
026305
026306
026307
026308
026309
026310
026311
026312
026313
026314
026315
026316

Number of
Conductors
2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76

Sheath
Thickness
in mm
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.110 2.8
.110 2.8
.125 3.2
.125 3.2

Cable Diameter
(nominal)
in mm
.605 15.4
.620 15.8
.665 16.9
.710 18.0
.750 19.1
.750 19.1
.800 20.3
.940 23.9
.965 24.5
1.085 27.6
1.175 29.9
1.280 32.5
1.340 34.0
1.490 37.9
1.640 41.7
1.875 47.6
2.180 55.4

Cable Weight
(approximate)
Lbs/mft Kg/km
250 372
285 424
325 484
370 551
415 618
435 647
485 722
620 923
680 1012
870 1295
1020 1518
1180 1756
1370 2039
1685 2508
1955 2909
2630 3914
3670 5462

Number of
Conductors
2
3
4
5
6
7
8
10

Insulation
Thickness
in mm
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76

Sheath
Thickness
in mm
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.080 2.0
.080 2.0
.080 2.0
.080 2.0

Cable Diameter
(nominal)
in mm
.670 17.0
.695 17.7
.750 19.1
.820 20.8
.895 22.7
.895 22.7
.950 24.1
1.112 28.5

Cable Weight
(approximate)
Lbs/mft Kg/km
315 469
370 551
430 640
500 744
600 893
640 952
710 1057
910 1354

10 AWG 5.53 mm2


Type
Designation
C10PNBS-2
C10PNBS-3
C10PNBS-4
C10PNBS-5
C10PNBS-6
C10PNBS-7
C10PNBS-8
C100PNBS-10

Draka
Number
026317
026318
026319
026320
026321
026322
026323
026324

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
12
6,503 3.30
10 10,908 5.53

95C
26
37

100C
31
41

110C
33
44

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 41 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
12 & 10 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

www.DrakaMOG.com

Bostrig Type P
0807
Page 42 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


multi-conductor / unarmored
12 & 10 AWG / 600V or 0.6/1kV
12 AWG 3.08 mm2
Type
Designation
C12PN-2
C12PN-3
C12PN-4
C12PN-5
C12PN-6
C12PN-7
C12PN-8
C12PN-10
C12PN-12
C12PN-16
C12PN-20
C12PN-24
C12PN-30
C12PN-37
C12PN-44
C12PN-60
C12PN-91

Draka
Number
026224
026225
026226
026227
026228
026229
026230
026231
026232
026233
026234
026235
026236
026237
026238
026239
026240

Number of
Conductors
2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76

Sheath
Thickness
in mm
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.110 2.8
.125 3.2

Cable Diameter
(nominal)
in mm
.425 10.8
.440 11.2
.475 12.1
.525 13.3
.570 14.5
.570 14.5
.620 15.6
.720 18.3
.745 18.9
.865 22.0
.955 24.3
1.060 26.9
1.120 28.5
1.210 30.7
1.355 34.4
1.565 39.8
1.880 47.8

Cable Weight
(approximate)
Lbs/mft Kg/km
100 149
135 201
155 231
190 283
220 327
245 365
280 417
355 528
400 595
550 818
680 1012
795 1183
955 1421
1140 1697
1390 2069
1880 2798
2800 4167

Number of
Conductors
2
3
4
5
6
7
8
10

Insulation
Thickness
in mm
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76

Sheath
Thickness
in mm
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.080 2.0

Cable Diameter
(nominal)
in mm
.490 12.5
.520 13.2
.565 14.4
.620 15.8
.675 17.2
.675 17.2
.730 18.5
.895 22.7

Cable Weight
(approximate)
Lbs/mft Kg/km
115 171
200 298
240 357
295 439
350 521
390 580
445 662
590 878

10 AWG 5.53 mm2


Type
Designation
C10PN-2
C10PN-3
C10PN-4
C10PN-5
C10PN-6
C10PN-7
C10PN-8
C10PN-10

Draka
Number
026241
026242
026243
026244
026245
026246
026247
026248

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
12
6,503 3.30
10 10,908 5.53

95C
26
37

100C
31
41

110C
33
44

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 39 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
14 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on oppposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

www.DrakaMOG.com

Bostrig Type P
0807
Page 40 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


multi-conductor / unarmored
14 AWG / 600V or 0.6/1kV 1.94 mm2
Type
Designation

Draka
Number

Number of
Conductors

C14PN-2
C14PN-3
C14PN-4
C14PN-5
C14PN-6
C14PN-7
C14PN-8
C14PN-10
C14PN-12
C14PN-16
C14PN-20
C14PN-24
C14PN-30
C14PN-37
C14PN-44
C14PN-60
C14PN-91

026207
026208
026209
026210
026211
026212
026213
026214
026215
026216
026217
026218
026219
026220
026297
026298
026299

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080

.380 6.7
.390 9.9
.430 10.9
.475 12.1
.515 13.1
.515 13.1
.560 14.2
.650 16.5
.670 17.0
.740 18.8
.820 20.8
.950 24.1
1.005 25.5
1.080 27.4
1.215 30.9
1.345 34.2
1.650 41.9

77 115
100 149
115 171
147 218
165 246
180 268
210 313
260 387
290 432
375 558
495 737
585 871
695 1034
850 1265
990 1473
1300 1935
1980 2947

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
14
4,106 2.08

95C
20

100C
25

110C
27

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 37 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
16 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

www.DrakaMOG.com

Bostrig Type P
0807
Page 38 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


multi-conductor / unarmored
16 AWG / 600V or 0.6/1kV 1.23 mm2
Type
Designation

Draka
Number

Number of
Conductors

C16PN-2
C16PN-3
C16PN-4
C16PN-5
C16PN-6
C16PN-7
C16PN-8
C16PN-10
C16PN-12
C16PN-16
C16PN-20
C16PN-24
C16PN-30
C16PN-37
C16PN-44
C16PN-60
C16PN-91

026190
026191
026192
026193
026194
026195
026196
026197
026198
026199
026200
026201
026202
026203
026204
026205
026206

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080

.355 9.0
.370 9.4
.400 10.2
.440 11.2
.475 12.1
.475 12.1
.540 13.7
.595 15.1
.610 15.5
.675 17.2
.745 18.9
.840 21.3
.915 23.2
.985 25.0
1.100 27.9
1.220 31.0
1.480 37.6

65 97
80 119
95 141
115 171
135 201
145 216
160 238
200 298
225 335
285 424
350 521
440 655
520 774
625 930
735 1094
960 1429
1470 2188

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
16
2,061 1.32

95C
16

100C
17

110C
18

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 13 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed

TYPE P CONTROL CABLE


600V or 0.6/1kV
16 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

www.DrakaMOG.com

Bostrig Type P
0807
Page 14 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV


multi-conductor / armored and sheathed
16 AWG / 600V or 0.6/1kV 1.23 mm2
Type
Designation
C16PNBS-2
C16PNBS-3
C16PNBS-4
C16PNBS-5
C16PNBS-6
C16PNBS-7
C16PNBS-8
C16PNBS-10
C16PNBS-12
C16PNBS-16
C16PNBS-20
C16PNBS-24
C16PNBS-30
C16PNBS-37
C16PNBS-44
C16PNBS-60
C16PNBS-91

Draka
Number

Number of
Conductors

026266
026267
0262668
026269
026270
026271
026272
026273
026274
026275
026276
026277
026278
026279
026280
026281
026282

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080
.080
.110
.110

.535 13.6
.545 13.8
.590 15.0
.620 15.8
.655 16.6
.655 16.6
.720 18.3
.775 19.7
.790 20.1
.895 22.7
.965 24.5
1.050 26.7
1.135 28.8
1.205 30.6
1.320 33.5
1.500 38.1
1.770 45.0

190 283
205 305
235 350
265 394
295 439
300 446
340 506
400 595
430 640
545 811
635 945
755 1124
865 1287
995 1480
1125 1674
1495 2225
2100 3125

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.0
2.8
2.8

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with 4 or more Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
16
2,601 1.32

95C
16

100C
17

110C
18

10

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 35 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
18 AWG
1

Approvals

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an armored and
sheathed version.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

11

www.DrakaMOG.com

Bostrig Type P
0807
Page 36 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


multi-conductor / unarmored
18 AWG / 600V or 0.6/1kV 0.96 mm2
Type
Designation

Draka
Number

Number of
Conductors

C18PN-2
C18PN-3
C18PN-4
C18PN-5
C18PN-6
C18PN-7
C18PN-8
C18PN-10
C18PN-12
C18PN-16
C18PN-20
C18PN-24
C18PN-30
C18PN-37
C18PN-44
C18PN-60
C18PN-91

026173
026174
026175
026176
026177
026178
026179
026180
026181
026182
026183
026184
026185
026186
026187
026188
026189

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080

.340 8.6
.360 9.1
.390 9.9
.425 10.8
.460 11.7
.460 11.7
.490 12.5
.570 14.5
.585 14.9
.660 16.8
.715 18.2
.790 20.1
.875 22.2
.940 23.9
1.055 26.8
1.165 29.6
1.390 35.3

55 82
70 104
85 127
100 149
120 179
130 193
140 208
175 260
195 290
250 372
305 454
355 528
455 677
545 811
640 952
835 1243
1220 1816

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
18
1,620 0.82

95C
11

100C
12

110C
13

12

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 11 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed

TYPE P CONTROL CABLE


600V or 0.6/1kV
18 AWG
1

Approvals

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

13

www.DrakaMOG.com

Bostrig Type P
0807
Page 12 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV


multi-conductor / armored and sheathed
18 AWG / 600V or 0.6/1kV 0.96 mm2
Type
Designation

Draka
Number

Number of
Conductors

C18PNBS-2
C18PNBS-3
C18PNBS-4
C18PNBS-5
C18PNBS-6
C18PNBS-7
C18PNBS-8
C18PNBS-10
C18PNBS-12
C18PNBS-16
C18PNBS-20
C18PNBS-24
C18PNBS-30
C18PNBS-37
C18PNBS-44
C18PNBS-60
C18PNBS-91

026249
026250
026251
026252
026253
026254
026255
026256
026257
026258
026259
026260
026261
026262
026263
026264
026265

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080
.080
.110
.110

.515 13.1
.540 13.7
.575 14.6
.605 15.4
.640 16.3
.640 16.3
.670 17.1
.750 19.1
.765 19.1
.885 22.5
.935 23.8
1.010 25.7
1.100 27.9
1.165 29.6
1.275 32.4
1.445 36.7
1.650 41.9

180 268
200 298
225 335
250 372
275 409
285 424
310 461
365 543
365 543
500 744
580 863
655 975
790 1176
900 1339
1035 1540
1355 2016
1860 2768

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.0
2.8
2.8

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
18
1,620 0.82

95C
11

100C
12

110C
13

14

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 27 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Two conductor / unarmored

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

This product is readily available in an armored and


sheathed version.

Transport Canada Approved AMS400-20-2

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)

Manufactured to BIW Specifying Standard J105

CONSTRUCTION
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600 & 2000V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V & 2000V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

15

www.DrakaMOG.com

Bostrig Type P
0807
Page 28 of 62

BOSTRIG TYPE P POWER CABLE


two conductor / unarmored
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Draka
Number

Conductor Size
AWG/MCM mm2

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

DPN-8

026043

8 7.57

.060 1.5

.590 15.0

0.70 2.3

0.12 0.4

95 312

58 64 69

210 313

DPN-6

026044

6 12.5

.060 1.5

.705 17.9

0.46 1.5

0.11 0.4

126 413

83 85 91

315 469

DPN-5

026045

5 18.6

.060 1.5

.810 20.6

0.33 1.1

0.11 0.4

140 459

95 101 108

440 655

DPN-4

026046

4 21.5

.080 2.0

.870 22.1

0.29 1.0

0.10 0.3

153 502

104 110 118

520 774

DPN-3

026047

3 25.6

.080 2.0

.920 23.4

0.23 0.8

0.10 0.3

173 567

121 132 141

605 900

DPN-2

026048

2 30.7

.080 2.0

.985 25.0

0.18 0.6

0.10 0.3

187 613

138 149 160

685 1019

DPN-1

026049

1 46.0

.080 2.0

1.150 29.2

0.14 0.5

0.09 0.3

178 584

168 174 186

975 1451

DPN-1/0

026050

1/0 56.3

.080 2.0

1.260 32.0

0.12 0.4

0.09 0.3

190 623

190 199 213

1150 1711

DPN-2/0

026051

2/0 66.5

.080 2.0

1.320 33.5

0.09 0.3

0.09 0.3

212 695

213 242 259

1285 1912

DPN-3/0

026052

3/0 92.1

.110 2.8

1.560 39.6

0.08 0.3

0.09 0.3

245 804

259 265 284

1860 2768

DPN-4/0

026053

4/0 112.6

.110 2.8

1.660 42.2

0.07 0.2

0.09 0.3

259 850

293 307 329

2215 3296

DPN-262

026054

262 133.0

.125 3.2

1.830 46.5

0.06 0.2

0.09 0.3

247 810

325 358 383

2605 3877

DPN-313

026055

313 158.6

.125 3.2

1.965 49.9

0.05 0.2

0.09 0.3

270 886

362 391 419

3035 4517

DPN-373

026056

373 189.3

.125 3.2

2.105 53.5

0.04 0.1

0.09 0.3

292 958

405 442 473

3615 5380

DPN-444

026057

444 225.1

.125 3.2

2.245 57.0

0.04 0.1

0.09 0.3

318 1043

451 504 540

4140 6161

DPN-535

026058

535 271.2

.140 3.6

2.4905 63.4

0.04 0.1

0.09 0.3

291 954

507 538 576

4960 7381

DPN-646

026059

646 327.5

.140 3.6

2.695 68.5

0.04 0.1

0.09 0.3

314 1030

570 632 677

5880 8750

DPN-777

026060

777 393.8

.140 3.6

2.900 73.7

0.03 0.1

0.09 0.3

345 1132

641 684 733

7030 10462

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

16

www.DrakaMOG.com

Bostrig Type P
0807
Page 3 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Two conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
1

8 AWG to 777 MCM

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

Transport Canada Approved AMS400-20-2


Manufactured to BIW Specifying Standard J104

This product is readily available in an unarmored version.

CONSTRUCTION
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

17

www.DrakaMOG.com

Bostrig Type P
0807
Page 4 of 62

BOSTRIG TYPE P POWER CABLE


two conductor / armored and sheathed
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

DPNBS-8

026108

8 7.57

.060 1.5

.765 19.4

0.70 2.3

0.12 0.4

95 312

58 64 69

405 603

DPNBS-6

026109

6 12.5

.080 2.0

.920 23.4

0.46 1.5

0.11 0.4

126 413

83 85 91

580 863

DPNBS-5

026110

5 18.6

.080 2.0

1.040 26.4

0.33 1.1

0.11 0.4

140 459

95 101 108

720 1071

DPNBS-4

026111

4 21.5

.080 2.0

1.090 27.7

0.29 1.0

0.10 0.3

153 502

104 110 118

850 1265

DPNBS-3

026112

3 25.6

.080 2.0

1.140 29.0

0.23 0.8

0.10 0.3

173 567

121 132 141

940 1399

DPNBS-2

026113

2 30.7

.080 2.0

1.205 30.6

0.18 0.6

0.10 0.3

187 613

138 149 160

1045 1555

DPNBS-1

026114

1 46.0

.110 2.8

1.430 36.3

0.14 0.5

0.09 0.3

178 584

168 174 186

1480 2202

DPNBS-1/0

026115

1/0 56.3

.110 2.8

1.535 39.0

0.12 0.4

0.09 0.3

190 623

190 199 213

1695 2522

DPNBS-2/0

026116

2/0 66.5

.110 2.8

1.600 40.6

0.09 0.3

0.09 0.3

212 695

213 242 259

1845 2746

DPNBS-3/0

026117

3/0 92.1

.125 3.2

1.870 47.5

0.08 0.3

0.09 0.3

245 804

259 265 284

2585 3825

DPNBS-4/0

026118

4/0 112.6

.125 3.2

1.975 50.2

0.07 0.2

0.09 0.3

259 850

293 307 329

2980 4435

DPNBS-262

026119

262 133.0

.125 3.2

2.145 54.5

0.06 0.2

0.09 0.3

247 810

325 358 383

3445 5127

DPNBS-313

026120

313 158.6

.140 3.6

2.305 58.6

0.05 0.2

0.09 0.3

270 886

362 391 419

4005 5960

DPNBS-373

026121

373 189.3

.140 3.6

2.445 62.1

0.04 0.1

0.09 0.3

292 958

405 442 473

4650 6920

DPNBS-444

026122

444 225.1

.140 3.6

2.585 65.7

0.04 0.1

0.09 0.3

318 1043

451 504 540

5240 7798

DPNBS-535

026123

535 271.2

.155 3.9

2.865 72.8

0.04 0.1

0.09 0.3

291 954

507 538 576

6175 9189

DPNBS-646

026124

646 327.5

.155 3.9

3.065 77.9

0.04 0.1

0.09 0.3

314 1030

570 632 677

7185 10692

DPNBS-777

026125

777 393.8

.155 3.9

3.270 83.01

0.03 0.1

0.09 0.3

345 1132

641 684 733

8420 12530

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

18

www.DrakaMOG.com

Bostrig Type P
0807
Page 5 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Three conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Approvals

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998)
for 600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

19

www.DrakaMOG.com

Bostrig Type P
0807
Page 6 of 62

BOSTRIG TYPE P POWER CABLE


three conductor / armored and sheathed
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

TPNBS-8

026126

8 7.57

.060 1.5

.835 21.2

0.70 2.3

0.12 0.4

95 312

47 52 56

480 714

TPNBS-6

026127

6 12.5

.080 2.0

.965 24.5

0.46 1.5

0.11 0.4

126 413

63 70 75

700 1042

TPNBS-5

026128

5 18.6

.080 2.0

1.120 28.5

0.33 1.1

0.11 0.4

140 459

78 82 88

900 1339

TPNBS-4

026129

4 21.5

.080 2.0

1.140 29.0

0.29 1.0

0.10 0.3

153 502

86 92 99

1040 1548

TPNBS-3

026130

3 25.6

.080 2.0

1.200 30.5

0.23 0.8

0.10 0.3

173 567

99 108 116

1160 1726

TPNBS-2

026131

2 30.7

.080 2.0

1.265 32.1

0.18 0.6

0.10 0.3

187 613

111 122 131

1295 1927

TPNBS-1

026132

1 46.1

.110 2.8

1.505 38.2

0.14 0.5

0.09 0.3

178 584

137 143 153

1850 2753

TPNBS-1/0

026133

1/0 56.3

.110 2.8

1.620 41.2

0.12 0.4

0.09 0.3

190 623

156 164 176

2190 3259

TPNBS-2/0

026134

2/0 66.5

.110 2.8

1.730 43.9

0.09 0.3

0.09 0.3

212 695

175 188 201

2500 3720

TPNBS-3/0

026135

3/0 92.1

.125 3.2

1.975 50.2

0.08 0.3

0.09 0.3

245 804

213 218 234

3330 4955

TPNBS-4/0

026136

4/0 112.6

.125 3.2

2.110 53.6

0.07 0.2

0.09 0.3

259 850

241 252 270

3890 5789

TPNBS-262

026137

262 133.0

.125 3.2

2.290 58.2

0.06 0.2

0.09 0.3

247 810

267 294 315

4515 6704

TPNBS-313

026138

313 158.6

.140 3.6

2.435 61.9

0.05 0.2

0.09 0.3

270 886

298 321 344

5170 7694

TPNBS-373

026139

373 189.3

.140 3.6

2.585 65.7

0.04 0.1

0.09 0.3

292 958

333 361 387

5975 8892

TPNBS-444

026140

444 225.1

.140 3.6

2.765 70.2

0.04 0.1

0.09 0.3

318 1043

371 411 440

6980 10387

TPNBS-535

026141

535 271.2

.140 3.6

3.030 77.0

0.04 0.1

0.09 0.3

291 954

417 443 475

8235 12255

TPNBS-646

026142

646 327.5

.140 3.6

3.275 83.2

0.04 0.1

0.09 0.3

314 1030

469 516 553

9575 14249

TPNBS-777

026143

777 393.8

.140 3.6

3.465 88.0

0.03 0.1

0.09 0.3

345 1132

528 562 602

11280 16786

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

20

www.DrakaMOG.com

Bostrig Type P
0807
Page 31 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Four conductor / unarmored

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

21

www.DrakaMOG.com

Bostrig Type P
0807
Page 32 of 62

BOSTRIG TYPE P POWER CABLE


four conductor / unarmored
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Draka
Number

Conductor Size
AWG/MCM mm2

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

FPN-8

026079

8 7.57

.060 1.5

.690 17.5

0.70 2.3

0.12 0.4

95 312

47 52 56

350 521

FPN-6

026080

6 12.5

.060 1.5

.820 20.8

0.46 1.5

0.11 0.4

126 413

63 70 75

540 804

FPN-5

026081

5 18.6

.080 2.0

.980 24.9

0.33 1.1

0.11 0.4

140 459

78 82 88

775 1153

FPN-4

026082

4 21.5

.080 2.0

1.020 25.9

0.29 1.0

0.10 0.3

153 502

86 92 99

885 1317

FPN-3

026083

3 25.6

.080 2.0

1.080 27.4

0.23 0.8

0.10 0.3

173 567

99 108 116

1025 1525

FPN-2

026084

2 30.7

.080 2.0

1.160 29.5

0.18 0.6

0.10 0.3

187 613

111 122 131

1170 1741

FPN-1

026085

1 46.1

.080 2.0

1.360 34.5

0.14 0.5

0.09 0.3

178 584

137 143 153

1710 2545

FPN-1/0

026086

1/0 56.3

.110 2.8

1.510 38.4

0.12 0.4

0.09 0.3

190 623

156 164 176

2100 3125

FPN-2/0

026087

2/0 66.5

.110 2.8

1.590 40.4

0.09 0.3

0.09 0.3

212 695

175 188 201

2410 3586

FPN-3/0

026088

3/0 92.1

.125 3.2

1.875 47.6

0.08 0.3

0.09 0.3

245 804

213 218 234

3360 5000

FPN-4/0

026089

4/0 112.6

.125 3.2

1.995 50.7

0.07 0.2

0.09 0.3

259 850

241 252 270

3940 5863

FPN-262

026090

262 133.0

.125 3.2

2.165 55.0

0.06 0.2

0.09 0.3

247 810

267 294 315

4640 6905

FPN-313

026091

313 158.6

.140 3.6

2.355 59.8

0.05 0.2

0.09 0.3

270 886

298 321 344

5475 8148

FPN-373

026092

373 189.3

.140 3.6

2.525 64.1

0.04 0.1

0.09 0.3

292 958

333 361 387

6365 9472

FPN-444

026093

444 225.1

.140 3.6

2.695 68.5

0.04 0.1

0.09 0.3

318 1043

371 411 440

7500 11161

FPN-535

026094

535 271.2

.140 3.6

2.990 76.0

0.04 0.1

0.09 0.3

291 954

417 443 475

8970 13349

FPN-646

026095

646 327.5

.140 3.6

3.230 82.0

0.04 0.1

0.09 0.3

314 1030

469 516 553

10640 15834

FPN-777

026096

777 393.8

.140 3.6

3.445 87.5

0.03 0.1

0.09 0.3

345 1132

528 562 602

12730 18944

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.
The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor. If all conductors are
current carrying, the ampacity must be reduced by 0.8.

22

www.DrakaMOG.com

Bostrig Type P
0807
Page 7 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Four conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables complywith the Crush and Impact requirements of
UL 2225.

23

www.DrakaMOG.com

Bostrig Type P
0807
Page 8 of 62

BOSTRIG TYPE P POWER CABLE


four conductor / armored and sheathed
8 AWG to 777 MCM / 600V or 0.6/1kV
Cable Diameter
(nominal)
in mm

Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

FPNBS-8

026144

8 7.57

.060 1.5

.910 23.1

0.70 2.3

0.13 0.4

95 312

47 52 56

605 900

FPNBS-6

026145

6 12.5

.080 2.0

1.045 26.5

0.46 1.5

0.12 0.4

126 413

63 70 75

890 1324

FPNBS-5

026146

5 18.6

.080 2.0

1.210 30.7

0.33 1.1

0.11 0.4

140 459

78 82 88

1140 1696

FPNBS-4

026147

4 21.5

.080 2.0

1.240 31.5

0.29 1.0

0.11 0.4

153 502

86 92 99

1265 1883

FPNBS-3

026148

3 25.6

.080 2.0

1.300 33.0

0.23 0.8

0.11 0.4

173 567

99 108 116

1415 2106

FPNBS-2

026149

2 30.7

.080 2.0

1.440 36.6

0.18 0.6

0.10 0.3

187 613

111 122 131

1675 2493

FPNBS-1

026150

1 46.1

.110 2.8

1.640 41.7

0.14 0.5

0.10 0.3

178 584

137 143 153

2300 3423

FPNBS-1/0

026151

1/0 56.3

.110 2.8

1.820 46.2

0.12 0.4

0.10 0.3

190 623

156 164 176

2860 4256

FPNBS-2/0

026152

2/0 66.5

.110 2.8

1.920 48.8

0.09 0.3

0.10 0.3

212 695

175 188 201

3150 4688

FPNBS-3/0

026153

3/0 92.1

.125 3.2

2.185 55.5

0.08 0.3

0.10 0.3

245 804

213 218 234

4220 6280

FPNBS-4/0

026154

4/0 112.6

.125 3.2

2.335 59.3

0.07 0.2

0.09 0.3

259 850

241 252 270

4920 7322

FPNBS-262

026155

262 133.0

.125 3.2

2.505 63.6

0.06 0.2

0.09 0.3

247 810

267 294 315

5700 8483

FPNBS-313

026156

313 158.6

.140 3.6

2.695 68.5

0.05 0.2

0.09 0.3

270 886

298 321 344

6620 9852

FPNBS-373

026157

373 189.3

.140 3.6

2.895 73.5

0.04 0.1

0.09 0.3

292 958

333 361 387

7590 11295

FPNBS-444

026158

444 225.1

.140 3.6

3.065 77.9

0.04 0.1

0.09 0.3

318 1043

371 411 440

8800 13096

FPNBS-535

026159

535 271.2

.140 3.6

3.360 85.3

0.04 0.1

0.09 0.3

291 954

417 443 475

10500 15626

FPNBS-646

026160

646 327.5

.140 3.6

3.600 91.4

0.04 0.1

0.09 0.3

314 1030

469 516 553

12290 18290

FPNBS-777

026161

777 393.8

.140 3.6

3.815 96.9

0.04 0.1

0.09 0.3

345 1132

528 562 602

14500 21578

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.
The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor. If all conductors are
current carrying, the ampacity must be reduced by 0.8.

24

www.DrakaMOG.com

Bostrig Type P
0807
Page 35

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Five conductor / unarmored

TYPE P POWER CABLE


600V or 0.6/1kV
8 to 4/0 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

25

www.DrakaMOG.com

Bostrig Type P
0807
Page 36

BOSTRIG TYPE P POWER CABLE


five conductor / unarmored
8 to 4/0 AWG / 600V or 0.6/1kV
Cable Diameter
(nominal)
in mm

Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Draka
Number

Conductor Size
AWG/MCM mm2

Jacket
Thickness
in mm

QPN-8

026097

8 7.57

.060 1.5

760 19.3

0.70 2.3

0.12 0.4

95 312

38 42 45

430 640

QPN-6

026098

6 12.5

.080 2.0

.955 24.3

0.46 1.5

0.11 0.4

126 413

50 56 60

700 1042

QPN-5

026099

5 18.6

.080 2.0

1.080 27.4

0.33 1.1

0.11 0.4

140 459

62 66 70

950 1414

QPN-4

026100

4 21.5

.080 2.0

1.125 28.6

0.29 1.0

0.10 0.3

153 502

69 74 79

1100 1637

QPN-3

026101

3 25.6

.110 2.8

1.195 30.4

0.23 0.8

0.10 0.3

173 567

79 86 93

1260 1875

QPN-2

026102

2 30.7

.110 2.8

1.280 32.5

0.18 0.6

0.10 0.3

187 613

89 98 105

1450 2158

QPN-1

026103

1 46.1

.125 3.2

1.565 39.8

0.14 0.5

0.09 0.3

178 584

110 114 122

2205 3282

QPN-1/0

026104

1/0 56.3

.125 3.2

1.715 43.6

0.12 0.4

0.09 0.3

190 623

125 131 141

2650 3945

QPN-2/0

026105

2/0 66.5

.125 3.2

1.790 45.5

0.09 0.3

0.09 0.3

212 695

140 150 161

3015 4487

QPN-3/0

026106

3/0 92.1

.140 3.6

2.075 52.7

0.08 0.3

0.09 0.3

245 804

170 174 187

4140 6161

QPN-4/0

026107

4/0 112.6

.140 3.6

2.210 56.1

0.07 0.2

0.09 0.3

259 850

193 202 216

4850 7218

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

26

www.DrakaMOG.com

Bostrig Type P
0807
Page 9 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Five conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
8 to 4/0 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

27

www.DrakaMOG.com

Bostrig Type P
0807
Page 10 of 62

BOSTRIG TYPE P POWER CABLE


five conductor / armored and sheathed
8 to 4/0 AWG / 600V or 0.6/1kV
Cable Diameter
(nominal)
in mm

Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

QPNBS-8

026162

8 7.57

.080 2.0

.980 24.9

0.70 2.3

0.13 0.4

95 312

38 42 45

710 1057

QPNBS-6

026163

6 12.5

.080 2.0

1.175 29.9

0.46 1.5

0.12 0.4

126 413

50 56 60

1045 1555

QPNBS-5

026164

5 18.6

.080 2.0

1.310 33.2

0.33 1.1

0.11 0.4

140 459

62 66 70

1350 2009

QPNBS-4

026165

4 21.5

.080 2.0

1.345 34.2

0.29 1.0

0.11 0.4

153 502

69 74 79

1510 2247

QPNBS-3

026166

3 25.6

.110 2.8

1.475 37.5

0.23 0.8

0.11 0.4

173 567

79 86 93

1775 2642

QPNBS-2

026167

2 30.7

.110 2.8

1.560 39.6

0.18 0.6

0.10 0.3

187 613

89 98 105

2000 2976

QPNBS-1

026168

1 46.1

.125 3.2

1.875 47.6

0.14 0.5

0.10 0.3

178 584

110 114 122

2930 4360

QPNBS-1/0

026169

1/0 56.3

.125 3.2

2.025 51.4

0.12 0.4

0.10 0.3

190 623

125 131 141

3435 5112

QPNBS-2/0

026170

2/0 66.5

.125 3.2

2.120 53.9

0.09 0.3

0.10 0.3

212 695

140 150 161

3830 5700

QPNBS-3/0

026171

3/0 92.1

.140 3.6

2.415 61.3

0.08 0.3

0.10 0.3

245 804

170 174 187

5150 7664

QPNBS-4/0

026172

4/0 112.6

.140 3.6

2.550 64.8

0.07 0.2

0.09 0.3

259 850

193 202 216

5930 8825

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

28

www.DrakaMOG.com

Bostrig Type P
0807
Page 51 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V


Overall shielded multiconductor /
armored and sheathed

TYPE P SIGNAL CABLE


600V
1

20, 18 & 16 AWG

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an unarmored version.

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured tc BIW Specifying Standard J106

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket
5 Armor
6. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over the cabled core.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for
0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V.

29

www.DrakaMOG.com

Bostrig Type P
0807
Page 52 of 62

BOSTRIG TYPE P SIGNAL CABLE


overall shielded multiconductor / armored and sheathed
20, 18 & 16 AWG / 600V
20 AWG 0.61 mm2
Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

C(0S)20PNBS-3

026503

19/32

.030 0.76

.060 1.5

.533 13.5

185 275

C(0S)20PNBS-4

026504

19/32

.030 0.76

.060 1.5

.557 14.2

210 313

C(0S)20PNBS-5

026505

19/32

.030 0.76

.060 1.5

.586 14.8

230 342

C(0S)20PNBS-6

026506

19/32

.030 0.76

.060 1.5

.614 15.6

255 380

Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

C(0S)18PNBS-3

026507

19/30

.030 0.76

.060 1.5

.540 13.7

205 305

C(0S)18PNBS-4

026508

19/30

.030 0.76

.060 1.5

.569 14.5

231 344

C(0S)18PNBS-5

026509

19/30

.030 0.76

.060 1.5

.613 15.6

259 389

C(0S)18PNBS-6

026510

19/30

.030 0.76

.060 1.5

.345 16.4

286 426

25

19/30

.030 0.76

.060 1.5

1.074 27.3

705 1049

Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

C(0S)16PNBS-3

026511

19/29

.030 0.76

.060 1.5

.564 14.3

221 329

C(0S)16PNBS-4

026512

19/29

.030 0.76

.060 1.5

.584 14.8

242 360

C(0S)16PNBS-5

026513

19/29

.030 0.76

.060 1.5

.633 16.1

283 421

C(0S)16PNBS-6

026514

19/29

.030 0.76

.060 1.5

.666 16.9

313 466

12

19/29

.030 0.76

.060 1.5

.820 20.8

470 699

Type
Designation

18 AWG 0.96 mm2


Type
Designation

C(0S)18PNBS-25

16 AWG 1.23 mm2


Type
Designation

C(0S)16PNBS-12

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

30

www.DrakaMOG.com

Bostrig Type P
0807
Page 49 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V


Overall shielded multiconductor /
unarmored

TYPE P SIGNAL CABLE


600V
1

20, 18 & 16 AWG

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored version.

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured tc BIW Specifying Standard J106

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for
0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V & 2000V.

31

www.DrakaMOG.com

Bostrig Type P
0807
Page 50 of 62

BOSTRIG TYPE P SIGNAL CABLE


overall shielded multiconductor / unarmored
20, 18 & 16 AWG / 600V
20 AWG 0.61 mm2
Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

C(0S)20PN-3

026491

19/32

.030 0.76

.060 1.5

.345 8.8

65 97

C(0S)20PN-4

026492

19/32

.030 0.76

.060 1.5

.373 9.5

81 121

C(0S)20PN-5

026493

19/32

.030 0.76

.060 1.5

.403 10.2

92 137

C(0S)20PN-6

026494

19/32

.030 0.76

.060 1.5

.431 10.9

107 159

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km
78 116

Type
Designation

Cable Weight
(approximate)
Lbs/mft Kg/km

18 AWG 0.96 mm2


Type
Designation

Draka
Number

C(0S)18PN-3

19/30

.030 0.76

.060 1.5

.358 9.1

C(0S)18PN-4

026496

19/30

.030 0.76

.060 1.5

.385 9.8

92 137

C(0S)18PN-5

026497

19/30

.030 0.76

.060 1.5

.435 11.0

113 168

C(0S)18PN-6

026498

19/30

.030 0.76

.060 1.5

.467 11.9

130 193

25

19/30

.030 0.76

.060 1.5

.795 20.2

395 588

Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

C(0S)16PN-3

030645

19/29

.030 0.76

.060 1.5

.386 9.8

88 131

C(0S)16PN-4

026500

19/29

.030 0.76

.060 1.5

.400 10.2

104 155

C(0S)16PN-5

026501

19/29

.030 0.76

.060 1.5

.455 11.6

130 193

C(0S)16PN-6

026502

19/29

.030 0.76

.060 1.5

.488 12.4

150 223

C(0S)16PN-12

027052

12

19/29

.030 0.76

.060 1.5

.625 15.9

260 387

C(0S)18PN-25

16 AWG 1.23 mm2


Type
Designation

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

32

www.DrakaMOG.com

Bostrig Type P
0807
Page 45 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
unarmored

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

16 & 14 AWG

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

This product is readily available in an armored and


sheathed version.

Transport Canada Approved AMS400-20-2

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)

Manufactured tc BIW Specifying Standard J106

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

33

www.DrakaMOG.com

Bostrig Type P
0807
Page 46 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multipair / unarmored and sheathed
16 & 14 AWG / 600V or 0.6/1kV
16 AWG 1.23 mm2
Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Thickness
in mm

TP(0S)16PN-1

026364

.030 0.76

.060 1.5

.350 8.9

65 97

TP(I/S-0S)16PN-2

026365

.030 0.76

.060 1.5

.620 15.6

170 253

TP(I/S-0S)16PN-3

026366

.030 0.76

.060 1.5

.665 16.9

215 320

TP(I/S-0S)16PN-4

026367

.030 0.76

.060 1.5

.695 17.7

240 357

TP(I/S-0S)16PN-5

026368

.030 0.76

.060 1.5

.740 18.8

275 409

TP(I/S-0S)16PN-6

026369

.030 0.76

.060 1.5

.805 20.1

320 476

TP(I/S-0S)16PN-7

026370

.030 0.76

.060 1.5

.805 20.1

345 513

TP(I/S-0S)16PN-8

026371

.030 0.76

.080 2.0

.985 25.0

475 707

TP(I/S-0S)16PN-10

026372

10

.030 0.76

.080 2.0

1.010 25.7

510 759

TP(I/S-0S)16PN-12

026373

12

.030 0.76

.080 2.0

1.065 27.1

585 871

TP(I/S-0S)16PN-16

026374

16

.030 0.76

.080 2.0

1.185 30.1

750 1116

TP(I/S-0S)16PN-20

026375

20

.030 0.76

.080 2.0

1.305 33.2

915 1362

TP(I/S-0S)16PN-24

026376

24

.030 0.76

.110 2.8

1.520 38.6

1165 1734

Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP(0S)14PN-1

026377

.030 0.76

.060 1.5

.395 10.0

85 126

TP(I/S-0S)14PN-2

026378

.030 0.76

.060 1.5

.640 16.3

180 268

TP(I/S-0S)14PN-3

026379

.030 0.76

.060 1.5

.680 17.3

235 350

TP(I/S-0S)14PN-4

026380

.030 0.76

.060 1.5

.650 19.1

290 432

TP(I/S-0S)14PN-5

026381

.030 0.76

.060 1.5

.810 20.6

345 513

TP(I/S-0S)14PN-6

026382

.030 0.76

.080 2.0

.920 23.4

450 670

TP(I/S-0S)14PN-7

026383

.030 0.76

.080 2.0

.920 23.4

475 707

TP(I/S-0S)14PN-8

026384

.030 0.76

.080 2.0

.995 25.3

540 804

TP(I/S-0S)14PN-10

026385

10

.030 0.76

.080 2.0

1.070 27.2

635 945

TP(I/S-0S)14PN-12

026386

12

.030 0.76

.080 2.0

1.165 29.6

760 1131

TP(I/S-0S)14PN-16

026387

16

.030 0.76

.080 2.0

1.300 33.0

975 1451

TP(I/S-0S)14PN-20

026388

20

.030 0.76

.110 2.8

1.490 37.9

1280 1905

TP(I/S-0S)14PN-24

026389

24

.030 0.76

.110 2.8

1.670 42.4

1515 2255

Type
Designation

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

14 AWG 1.94 mm2


Type
Designation

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

34

www.DrakaMOG.com

Bostrig Type P
0807
Page 21 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
armored and sheathed

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

16 & 14 AWG
Approvals
ETL/Intertek Testing Services Listed as Marine Shipboard
Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J106

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket
5 Armor
6. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

35

www.DrakaMOG.com

Bostrig Type P
0807
Page 22 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multipair / armored and sheathed
16 & 14 AWG / 600V or 0.6/1kV
16 AWG 1.23 mm2
Type
Designation

Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Cable Diameter
Thickness
(nominal)
in mm
in mm

Characteristic
Impedance

TP(0S)16PNBS-1

026429

.030 0.76

.060 1.5

.535 13.6

68 223

0.12 39

25 82

190 283

TP(I/S-0S)16PNBS-2

026430

.030 0.76

.060 1.5

.805 20.5

68 223

0.12 39

25 82

350 521

TP(I/S-0S)16PNBS-3

026431

.030 0.76

.080 2.0

.885 22.5

68 223

0.12 39

25 82

425 632

TP(I/S-0S)16PNBS-4

026432

.030 0.76

.080 2.0

.920 23.4

68 223

0.12 39

25 82

490 729

TP(I/S-0S)16PNBS-5

026433

.030 0.76

.080 2.0

.965 24.5

68 223

0.12 39

25 82

545 811

TP(I/S-0S)16PNBS-6

026434

.030 0.76

.080 2.0

1.025 26.0

68 223

0.12 39

25 82

610 908

TP(I/S-0S)16PNBS-7

026435

.030 0.76

.080 2.0

1.025 26.0

68 223

0.12 39

25 82

635 945

TP(I/S-0S)16PNBS-8

026436

.030 0.76

.080 2.0

1.205 30.6

68 223

0.12 39

25 82

800 1191

TP(I/S-0S)16PNBS-10

026437

10

.030 0.76

.080 2.0

1.235 31.4

68 223

0.12 39

25 82

875 1302

TP(I/S-0S)16PNBS-12

026438

12

.030 0.76

.080 2.0

1.285 32.6

68 223

0.12 39

25 82

965 1436

TP(I/S-0S)16PNBS-16

026439

16

.030 0.76

.110 2.8

1.465 37.2

68 223

0.12 39

25 82

1255 1868

TP(I/S-0S)16PNBS-20

026440

20

.030 0.76

.110 2.8

1.585 40.2

68 223

0.12 39

25 82

1470 2188

TP(I/S-0S)16PNBS-24

026441

24

.030 0.76

.125 3.2

1.835 46.6

68 223

0.12 39

25 82

1860 2786

/kft - /km

Cable Weight
Inductance
Capacitance (approximate)
mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km

14 AWG 1.94 mm2


Type
Designation

Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Cable Diameter
Thickness
(nominal)
in mm
in mm

Characteristic
Impedance

TP(0S)14PNBS-1

026693

.030 0.76

.060 1.5

.575 14.6

60 197

0.10 33

28 92

220 327

TP(I/S-0S)14PNBS-2

026443

.030 0.76

.060 1.5

.820 20.8

68 223

0.12 39

25 82

385 573

TP(I/S-0S)14PNBS-3

026444

.030 0.76

.080 2.0

.900 22.9

68 223

0.12 39

25 82

490 729

TP(I/S-0S)14PNBS-4

026445

.030 0.76

.080 2.0

.970 24.6

68 223

0.12 39

25 82

575 856

TP(I/S-0S)14PNBS-5

026446

.030 0.76

.080 2.0

1.030 26.2

68 223

0.12 39

25 82

650 967

TP(I/S-0S)14PNBS-6

026447

.030 0.76

.080 2.0

1.140 29.0

68 223

0.12 39

25 82

780 1161

TP(I/S-0S)14PNBS-7

026448

.030 0.76

.080 2.0

1.140 29.0

68 223

0.12 39

25 82

810 1205

TP(I/S-0S)14PNBS-8

026449

.030 0.76

.080 2.0

1.215 30.9

68 223

0.12 39

25 82

900 1339

TP(I/S-0S)14PNBS-10

026450

10

.030 0.76

.080 2.0

1.290 32.8

68 223

0.12 39

25 82

1030 1533

TP(I/S-0S)14PNBS-12

026451

12

.030 0.76

.110 2.8

1.445 36.7

68 223

0.12 39

25 82

1250 1860

TP(I/S-0S)14PNBS-16

026452

16

.030 0.76

.110 2.8

1.580 40.1

68 223

0.12 39

25 82

1525 2269

TP(I/S-0S)14PNBS-20

026453

20

.030 0.76

.125 3.2

1.800 45.7

68 223

0.12 39

25 82

1960 2917

TP(I/S-0S)14PNBS-24

026454

24

.030 0.76

.125 3.2

1.980 50.3

68 223

0.12 39

25 82

2260 3363

/kft - /km

Cable Weight
Inductance
Capacitance (approximate)
mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

36

www.DrakaMOG.com

Bostrig Type P
0807
Page 43 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
1

20 & 18 AWG

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured tc BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test
in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45
(1998) for 600V.
Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225.

37

www.DrakaMOG.com

Bostrig Type P
0807
Page 44 of 62

BOSTRIG TYPE P CONTROL CABLE


individual and overall shielded multipair / unarmored
20 & 18 AWG / 600V or 0.6/1kV
20 AWG 0.61 mm2
Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Thickness
in mm

TP(0S)20PN-1

026338

.030 0.76

.060 1.5

.330 8.4

55 92

TP(I/S-0S)20PN-2

026339

.030 0.76

.060 1.5

.540 13.7

120 179

TP(I/S-0S)20PN-3

026340

.030 0.76

.060 1.5

.550 13.9

135 201

TP(I/S-0S)20PN-4

026341

.030 0.76

.060 1.5

.600 15.2

165 246

TP(I/S-0S)20PN-5

026342

.030 0.76

.060 1.5

.650 16.5

190 283

TP(I/S-0S)20PN-6

026343

.030 0.76

.060 1.5

.700 17.8

215 320

TP(I/S-0S)20PN-7

026344

.030 0.76

.060 1.5

.700 17.8

230 342

TP(I/S-0S)20PN-8

026345

.030 0.76

.060 1.5

.760 19.3

265 394

TP(I/S-0S)20PN-10

026346

10

.030 0.76

.080 2.0

.900 22.9

360 536

TP(I/S-0S)20PN-12

026347

12

.030 0.76

.080 2.0

.925 23.5

400 595

TP(I/S-0S)20PN-16

026348

16

.030 0.76

.080 2.0

1.030 26.2

510 759

TP(I/S-0S)20PN-20

026349

20

.030 0.76

.080 2.0

1.130 28.7

600 893

TP(I/S-0S)20PN-24

026350

24

.030 0.76

.080 2.0

1.265 32.1

720 1071

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

Type
Designation

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

18 AWG 0.96 mm2


Type
Designation

Draka
Number

TP(0S)18PN-1

.030 0.76

.060 1.5

.350 8.9

65 97

TP(I/S-0S)18PN-2

026352

.030 0.76

.060 1.5

.605 15.4

160 238

TP(I/S-0S)18PN-3

026353

.030 0.76

.060 1.5

.635 16.1

180 268

TP(I/S-0S)18PN-4

026354

.030 0.76

.060 1.5

.675 17.2

225 335

TP(I/S-0S)18PN-5

026355

.030 0.76

.060 1.5

.710 18.0

245 365

TP(I/S-0S)18PN-6

026356

.030 0.76

.060 1.5

.765 19.4

285 424

TP(I/S-0S)18PN-7

026357

.030 0.76

.060 1.5

.800 20.3

340 506

TP(I/S-0S)18PN-8

026358

.030 0.76

.080 2.0

.960 24.4

440 655

TP(I/S-0S)18PN-10

026359

10

.030 0.76

.080 2.0

1.025 26.0

515 766

TP(I/S-0S)18PN-12

026360

12

.030 0.76

.080 2.0

1.045 26.5

565 841

TP(I/S-0S)18PN-16

026361

16

.030 0.76

.080 2.0

1.160 29.5

720 1071

TP(I/S-0S)18PN-20

026362

20

.030 0.76

.080 2.0

1.240 31.5

825 1228

TP(I/S-0S)18PN-24

026363

24

.030 0.76

.110 2.8

1.450 36.8

1060 1577

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

38

www.DrakaMOG.com

Bostrig Type P
0807
Page 19 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
armored and sheathed

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

20 & 18 AWG

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J106

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket
5. Armor
6. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

39

www.DrakaMOG.com

Bostrig Type P
0807
Page 20 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multipair / armored and sheathed
20 & 18 AWG / 600V or 0.6/1kV
20 AWG 0.61 mm2
Type
Designation

Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Cable Diameter
Thickness
(nominal)
in mm
in mm

Characteristic
Impedance

TP(0S)20PNBS-1

026403

.030 0.76

.060 1.5

.510 13.0

82 269

0.14 46

21 69

170 253

TP(I/S-0S)20PNBS-2

026404

.030 0.76

.060 1.5

.720 18.3

82 269

0.14 46

21 69

295 439

TP(I/S-0S)20PNBS-3

026405

.030 0.76

.060 1.5

.730 18.5

82 269

0.14 46

21 69

320 476

TP(I/S-0S)20PNBS-4

026406

.030 0.76

.060 1.5

.780 19.8

82 269

0.14 46

21 69

360 536

TP(I/S-0S)20PNBS-5

026407

.030 0.76

.080 2.0

.890 22.6

82 269

0.14 46

21 69

440 655

TP(I/S-0S)20PNBS-6

026408

.030 0.76

.080 2.0

.925 23.5

82 269

0.14 46

21 69

485 722

TP(I/S-0S)20PNBS-7

026409

.030 0.76

.080 2.0

.925 23.5

82 269

0.14 46

21 69

500 744

TP(I/S-0S)20PNBS-8

026410

.030 0.76

.080 2.0

.980 24.9

82 269

0.14 46

21 69

550 818

TP(I/S-0S)20PNBS-10

026411

10

.030 0.76

.080 2.0

1.120 28.5

82 269

0.14 46

21 69

690 1027

TP(I/S-0S)20PNBS-12

026412

12

.030 0.76

.080 2.0

1.150 29.2

82 269

0.14 46

21 69

730 1086

TP(I/S-0S)20PNBS-16

026413

16

.030 0.76

.080 2.0

1.250 31.8

82 269

0.l4 46

21 69

885 1317

TP(I/S-0S)20PNBS-20

026414

20

.030 0.76

.080 2.0

1.350 34.3

82 269

0.14 46

21 69

1060 1577

TP(I/S-0S)20PNBS-24

026415

24

.030 0.76

.110 2.8

1.545 39.2

82 269

0.14 46

21 69

1260 1875

Insulation
Thickness
in mm

Sheath
Cable Diameter
Thickness
(nominal)
in mm
in mm

/kft - /km

Cable Weight
Inductance
Capacitance (approximate)
mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km

18 AWG 0.96 mm2


Characteristic
Impedance

Cable Weight
Inductance
Capacitance (approximate)
mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km

Type
Designation

Draka
Number

Number of
Pairs

TP(0S)18PNBS-1

026664

.030 0.76

.060 1.5

.535 13.6

73 239

0.13 43

23 75

185 275

TP(I/S-0S)18PNBS-2

026417

.030 0.76

.060 1.5

.785 19.5

73 239

0.13 43

23 75

350 521

TP(I/S-0S)18PNBS-3

026418

.030 0.76

.060 1.5

.845 21.5

73 239

0.13 43

23 75

395 588

TP(I/S-0S)18PNBS-4

026419

.030 0.76

.080 2.0

.895 22.7

73 239

0.13 43

23 75

465 692

TP(I/S-0S)18PNBS-5

026420

.030 0.76

.080 2.0

.930 23.6

73 239

0.13 43

23 75

505 752

TP(I/S-0S)18PNBS-6

026421

.030 0.76

.080 2.0

.990 25.2

73 239

0.13 43

23 75

570 848

TP(I/S-0S)18PNBS-7

026422

.030 0.76

.080 2.0

1.020 25.9

73 239

0.13 43

23 75

605 900

TP(I/S-0S)18PNBS-8

026423

.030 0.76

.080 2.0

1.180 30.0

73 239

0.13 43

23 75

725 1079

TP(I/S-0S)18PNBS-10

026424

10

.030 0.76

.080 2.0

1.245 31.6

73 239

0.13 43

23 75

845 1257

TP(I/S-0S)18PNBS-12

026425

12

.030 0.76

.080 2.0

1.265 32.1

73 239

0.13 43

23 75

910 1354

TP(I/S-0S)18PNBS-16

026426

16

.030 0.76

.110 2.8

1.440 36.6

73 239

0.13 43

23 75

1135 1689

TP(I/S-0S)18PNBS-20

026427

20

.030 0.76

.110 2.8

1.520 38.6

73 239

0.13 43

23 75

1350 2009

TP(I/S-0S)18PNBS-24

026428

24

.030 0.76

.110 2.8

1.760 44.7

73 239

0.13 43

23 75

1680 2500

/kft - /km

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

40

www.DrakaMOG.com

Bostrig Type P
0807
Page 47 of 62

BOSTRIG TYPE P SIGNAL CABLE


Individual and overall shielded multi-triad
/ unarmored

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

18 & 16 AWG

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured tc BIW Specifying Standard J106

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

41

www.DrakaMOG.com

Bostrig Type P
0807
Page 48 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multitriad / unarmored
18 & 16 AWG / 0.6/1kV
18 AWG 0.96 mm2
Type
Designation

Draka
Number

TT(0S)18PN-1

Number of
Triads

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.030 0.76

.060 1.5

.360 9.1

75 111

TT(I/S-0S)18PN-2

026456

.030 0.76

.060 1.5

.605 15.4

165 246

TT(I/S-0S)18PN-3

026457

.030 0.76

.060 1.5

.640 16.3

210 313

TT(I/S-0S)18PN-4

026458

.030 0.76

.060 1.5

.705 17.9

265 394

TT(I/S-0S)18PN-5

026459

.030 0.76

.060 1.5

.775 19.7

315 469

TT(I/S-0S)18PN-6

026460

.030 0.76

.080 2.0

.880 22.4

390 580

TT(I/S-0S)18PN-8

026461

.030 0.76

.080 2.0

.955 24.5

495 737

TT(I/S-0S)18PN-12

026462

12

.030 0.76

.080 2.0

1.155 29.3

715 1064

Draka
Number

Number of
Triads

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TT(0S)16PN-1

026625

.030 0.76

.060 1.5

.370 9.4

85 126

TT(I/S-0S)16PN-2

026465

.030 0.76

.060 1.5

.630 16.0

180 268

TT(I/S-0S)16PN-3

026466

.030 0.76

.060 1.5

.670 17.0

235 350

TT(I/S-0S)16PN-4

026467

.030 0.76

.060 1.5

.740 18.8

295 439

TT(I/S-0S)16PN-5

026468

.030 0.76

.060 1.5

.815 20.7

355 528

TT(I/S-0S)16PN-6

026469

.030 0.76

.080 2.0

.915 23.1

446 662

TT(I/S-0S)16PN-8

026470

.030 0.76

.080 2.0

1.070 27.2

625 930

TT(I/S-0S)16PN-12

026471

12

.030 0.76

.080 2.0

1.215 30.9

805 1198

TT(I/S-0S)16PN-16

026472

16

.030 0.76

.080 2.0

1.360 34.5

1050 1563

16 AWG 1.23 mm2


Type
Designation

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

42

www.DrakaMOG.com

Bostrig Type P
0807
Page 23 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multi-triad
/ armored and sheathed

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

18 & 16 AWG

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J106

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket
5 Armor
6. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

43

www.DrakaMOG.com

Bostrig Type P
0807
Page 24 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multi-triad / armored and sheathed
18 & 16 AWG / 0.6/1kV
18 AWG 0.96 mm2
Type
Designation

Draka
Number

Number of
Triads

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TT(0S)18PNBS-1

026473

.030 0.76

.060 1.5

.540 13.7

200 298

TT(I/S-0S)18PNBS-2

026474

.030 0.76

.060 1.5

.785 19.9

360 536

TT(I/S-0S)18PNBS-3

026475

.030 0.76

.060 1.5

.850 21.6

430 640

TT(I/S-0S)18PNBS-4

026476

.030 0.76

.080 2.0

.930 23.6

525 781

TT(I/S-0S)18PNBS-5

026477

.030 0.76

.080 2.0

.995 25.3

590 878

TT(I/S-0S)18PNBS-6

026478

.030 0.76

.080 2.0

1.100 28.0

715 1064

TT(I/S-0S)18PNBS-8

026479

.030 0.76

.080 2.0

1.175 29.9

825 1228

TT(I/S-0S)18PNBS-12

026480

12

.030 0.76

.110 2.8

1.440 36.6

1180 1756

TT(I/S-0S)18PNBS-16

026481

16

.030 0.76

.110 2.8

1.570 39.9

1450 2158

16 AWG 1.23 mm2


Type
Designation

Draka
Number

Number of
Triads

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TT(0S)16PNBS-1

026716

.030 0.76

.060 1.5

.550 14.0

210 313

TT(I/S-0S)16PNBS-2

026483

.030 0.76

.060 1.5

.810 20.6

380 566

TT(I/S-0S)16PNBS-3

026484

.030 0.76

.080 2.0

.890 22.6

485 722

TT(I/S-0S)16PNBS-4

026485

.030 0.76

.080 2.0

.960 24.4

570 848

TT(I/S-0S)16PNBS-5

026486

.030 0.76

.080 2.0

1.035 26.3

645 960

TT(I/S-0S)16PNBS-6

026487

.030 0.76

.080 2.0

1.130 28.7

770 1146

TT(I/S-0S)16PNBS-8

026488

.030 0.76

.080 2.0

1.290 32.8

950 1414

TT(I/S-0S)16PNBS-12

026489

12

.030 0.76

.110 2.8

1.495 38.0

1280 1905

TT(I/S-0S)16PNBS-16

026490

16

.030 0.76

.110 2.8

1.640 41.7

1565 2329

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

44

www.DrakaMOG.com

Bostrig Type P
0807
Page 57 of 62

BOSTRIG TYPE P-VFD POWER CABLE 2000V


Shielded three conductor / unarmored or
armored and sheathed

TYPE P VFD CABLE


2000V
1

1/0 AWG to 777 MCM

Applications
BostrigTM Type P shielded three conductor VFD Marine and Offshore Cable is designed specifically for use with
variable frequency AC motor drives. This cable is ETL listed per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.
Bostrig cables have excellent resistance to oil, abrasion, moisture and sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I applications (armored & sheathed) and meet the crush and
impact resistance requirements (C&IR) of UL 2225 and complies with UL 1277 Type TC exposed runs requirements.
The standard insulation has a continuous operating temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product can be manufactured in an unarmored or armored and sheathed version.

Construction
1. Conductors
2. Insulation
3. Ground Conductors

4. Shield
5. Jacket
6. Armor (Optional)
7. Sheath (Optional)

Soft annealed tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Insulation is printed with phase markings as required.
All Bostrig Type P-VFD Cables listed in this specification sheet are built using system
grounds equal to the aggregte cross-section of a phase conductor and can be in contact with
or isolated from the overall shield. A system ground is REQUIRED for supplying power from
the switchboard to the inverter and then to the motor. If the VFD cable is only being used
between the motor and the inverter, a cable with a lesser ground can be ordered.
Braided tinner cooper for 95% coverage.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001).
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Low smoke/zero halogen construction meets appropriate IEEE and IEC standards for fire, smoke, and toxicity
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Gigabit Ethernet 802.3Z compliant

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for 2000V.
Type approved by DNV, ABS, Lloyds and Transport Canada.
Bostrig Type P cables comply to UL 1277 Type TC exposed runs
requirements and with the crush and impact requirements of UL 2225.

45

www.DrakaMOG.com

Bostrig Type P
0807
Page 58 of 62

BOSTRIG TYPE P-VFD POWER CABLE


shielded three conductor / unarmored or armored and sheathed
1/0 AWG to 777 MCM / 2000V
unarmored
Ground Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Inductance
/kft - /km

Capacitance
pF/ft pF/m

Calculated Ampacity Cable Weight


(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

TP(OBS)N-1/0

036028

1/0 56.3

5 AWG 18.6

n/a

1.53 38.9

0.09 0.3

190 623

156 164 176

2280 3393

TP(OBS)N-2/0

036029

2/0 66.5

4 AWG 21.5

n/a

1.63 41.4

0.09 0.3

212 695

175 186 201

2640 3928

TP(OBS)N-4/0

036030

4/0 112.6

1 AWG 56.3

n/a

2.09 53.1

0.09 0.3

259 850

241 252 270

4480 6666

TP(OBS)N-262

036031

262 133.0

1 AWG 56.3

n/a

2.23 56.6

0.09 0.3

247 810

267 294 315

5050 7514

TP(OBS)N-313

036032

313 158.6

110 AWG 18.6

n/a

2.36 60.0

0.08 0.2

270 886

298 321 344

5860 8720

TP(OBS)N-373

036033

373 189.3

210 AWG 61.5

n/a

2.56 65.0

0.08 0.2

292 958

333 361 387

6950 10342

TP(OBS)N-444

036034

444 225.1

310 AWG 92.1

n/a

2.87 72.9

0.08 0.2

318 1043

371 411 440

8660 12886

TP(OBS)N-535

036035

535 271.2

310 AWG 92.1

n/a

3.03 77.0

0.09 0.3

291 954

417 443 475

9700 14437

TP(OBS)N-646

036036

646 327.5

410 AWG 112.6

n/a

3.18 80.8

0.09 0.3

314 1030

469 516 553

11400 16963

TP(OBS)N-777

036037

777 393.8

262 KCMIL 133.0

n/a

3.52 89.4

0.09 0.3

345 1132

528 582 602

13520 20118

Ground Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Inductance
/kft - /km

Capacitance
pF/ft pF/m

armored and sheathed


Calculated Ampacity Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

TP(OBS)NBS-1/0

036038

4/0 112.6

5 AWG 18.6

.11 2.8

1.82 46.2

0.09 0.3

190 623

156 164 176

3020 4494

TP(OBS)NBS-2/0

036039

4/0 112.6

4 AWG 21.5

.11 2.8

1.92 48.8

0.09 0.3

212 695

175 188 201

3420 5089

TP(OBS)NBS-4/0

036040

4/0 112.6

1 AWG 56.3

.11 2.8

2.38 60.4

0.09 0.3

259 850

241 252 270

5510 8199

TP(OBS)NBS-262

036041

262 133.1

1 AWG 56.3

.11 2.8

2.52 64.0

0.09 0.3

247 810

267 294 315

6130 9121

TP(OBS)NBS-313

036042

313 158.7

110 AWG 18.6

.11 2.8

2.65 67.3

0.08 0.2

270 886

298 321 344

7010 10431

TP(OBS)NBS-373

036043

373 189.2

210 AWG 61.5

.14 3.6

2.90 73.7

0.08 0.2

292 958

333 361 387

8360 12440

TP(OBS)NBS-444

036044

444 225.2

310 AWG 92.1

.14 3.6

3.21 81.5

0.08 0.2

318 1043

371 411 440

10230 15222

TP(OBS)NBS-535

036045

535 271.3

310 AWG 92.1

.14 3.6

3.37 85.6

0.09 0.3

291 954

417 443 475

11350 16889

TP(OBS)NBS-646

036046

646 327.5

410 AWG 112.6

.14 3.6

3.52 89.4

0.09 0.3

314 1030

469 516 553

13130 19537

TP(OBS)NBS-777

036047

777 394.2

262 KCMIL 133.0

.14 3.6

3.86 98.0

0.09 0.3

345 1132

528 582 602

15420 22944

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

PHASE CONDUCTOR (3)


SYSTEM GROUND (3)
FILLERS (AS REQUIRED)
MYLAR TAPE
BRAIDED SHIELD
JACKET
BRAIDED ARMOR
SHEATH

46

www.DrakaMOG.com

For maintenance and repair needs, or expert guidance for new-build


projects, please contact any of our worldwide locations:

EUROPE:
Unit 3 Peterseat Drive
Peterseat Park
Altens Industrial Estate
Aberdeen AB12 3HT
U.K.
tel: +44 1224 244800
fax: +44 1224 249839

AMERICAS:
1610 Greens Road, Suite
300
Houston, TX 77032
U.S.A.
tel: +1 281 209 1070
fax: +1 281 209 3857

www.DrakaMOG.com

2009 Draka Offshore. All rights reserved.

ASIA-PACIFIC:
25 Tuas South Street 1
Singapore 638034
tel: +65 6897 7888
fax: +65 6897 7333

You might also like