DPWH

Project: Item :

DESIGN SHEET
Pantar Bridge and Approaches Iligan City-Marawi City, Lanao del Norte

Region 10, Cagayan de Oro City Planning and Design Division


Prepared by: Engr.Jessie R. Tutor Checked by: Engr.Liberty M. Vallar

Hydrologic/ Hydraulic Analysis a.) DPWH Manual on Flood Control and Planning, March 2003

DESIGN CODES AND REFERENCES

DESIGN DATA: constant, C( Mindanao) Catchement Area, A Return Period = 12.80( Table 4.1 Constants for Regional Specific Discharge Curve) = 1,619.69 sq.km. = 50 years

SPECIFIC DISCHARGE
= (
. ) . )

= . , . (,.

= . /s
THUS, DISCHARGE, Q50 = 1.4086X1,619.61 = 2281.32 CU.M/SEC

DISCHARGE AT HIGHEST FLOOD LEVEL USING CROSS-SECTION OF THE CHANNEL:


13.131

HIGHEST FLOOD LEVEL=ELEV.(491.484)


2 1 40.015 66.277+40.015 [7.024] 2 14.048+40.015+ 14.048 A P 373 SQ.M 68.111M
2/3

7.024

n= .05(max) for mountain streams.

A P
R

373 SQ.M

68.111M

=
1/2

5.48

1 [5.48] 0.05 A x

[.0149]

7.588M/SEC

QHFL =

= 373 x 7.588 =

2,830.32CU.M/SEC

2,830.32CU.M/SEC

>

2281.32 CU.M/SEC

OK!!!