You are on page 1of 3

E R R O R

M E M O R Y
R E P O R T
------------------------------------Date:
03/30/13 11:03:14
ECU:
DDE40KW0
JobStatus: OKAY
Variant:
DDE40KW0
------------------------------------------------------------RESULT:
6 errors in error memory !
------------------------------------------------------------400

Rail-pressure sensor

Error frequency : 2
Logistic counter: 36
Error occured 1. times at:
Engine speed
fuel pre-supply pressure
Einspritzmenge
RPC rail pressure
Fehler aufgetreten bei

0.00
2.10
28.16
253.01
274570.00

1/min
bar
mm^3
bar
km

0.00
2.77
52.74
397.59
277940.00

1/min
bar
mm^3
bar
km

Error occured 2. times at:


Engine speed
fuel pre-supply pressure
Einspritzmenge
RPC rail pressure
Fehler aufgetreten bei
Error not present
Sporadic error
Open circuit or short circuit to B+
Errorcode: 01 90 24 02 F8 02 00 83 37 2A 6B 41 02 00 AD 67
42 6C 92 00 00 00 00 00 00
------------------------------------------------------------4501

Rail-pressure regulating valve

Error frequency : 255


Logistic counter: 39
Error occured 1. times at:
Engine speed
fuel pre-supply pressure
Supply voltage
RPC rail pressure
Fehler aufgetreten bei

149.85
3.04
10.07
60.24
277580.00

1/min
bar
V
bar
km

0.00
0.90
12.27
54.22
277940.00

1/min
bar
V
bar
km

0.00
2.98
11.57
6.02
277940.00

1/min
bar
V
bar
km

Error occured 2. times at:


Engine speed
fuel pre-supply pressure
Supply voltage
RPC rail pressure
Fehler aufgetreten bei
Error occured 3. times at:
Engine speed
fuel pre-supply pressure
Supply voltage
RPC rail pressure
Fehler aufgetreten bei
Error not present
Sporadic error
Short circuit to B+
Errorcode: 11 95 27 FF F8 04 06 BE 57 0A 6C 6E 04 00 38 6A
09 6C 92 04 00 BA 64 01 6C
------------------------------------------------------------7669

Electronic car immobilisation system (EWS)

Error frequency : 1
Logistic counter: 27
Engine speed
Coolant temperature
Einspritzmenge
RPC rail pressure
Fehler aufgetreten bei

0.00
-6.89
53.25
6.02
277940.00

1/min
Grad C
mm^3
bar
km

Error not present


EWS Timeout elapsed
Errorcode: 1D F5 1B 01 70 04 00 32 68 01 6C 92 00 00 00 00
00 00 00 00 00 00 00 00 00
------------------------------------------------------------1152

Electric fan

Error frequency : 1
Logistic counter: 30
Engine speed
Coolant temperature
Supply voltage
duty factor
Fehler aufgetreten bei

0.00
-6.21
8.91
4.73
277940.00

1/min
Grad C
V
%
km

Error not present


Controll circuit or short circuit to positive BErrorcode: 04 80 1E 01 70 08 00 33 4D 0C 6C 92 00 00 00 00
00 00 00 00 00 00 00 00 00
------------------------------------------------------------4496

Rail-pressure plausibility

Error frequency : 1
Logistic counter: 36
Engine speed
fuel pre-supply pressure
Einspritzmenge
RPC rail pressure
Fehler aufgetreten bei

1273.73
3.50
12.29
120.48
277940.00

1/min
bar
mm^3
bar
km

Error not present


Control deviation over engine speed too great
Errorcode: 11 90 24 01 70 20 33 DB 18 14 6C 92 00 00 00 00
00 00 00 00 00 00 00 00 00
------------------------------------------------------------2550

Rail pressure control at start

Error frequency : 3
Logistic counter: 39
Error occured 1. times at:
Engine speed
fuel pre-supply pressure
Einspritzmenge
RPC rail pressure
Fehler aufgetreten bei

174.83
3.47
51.72
72.29
277940.00

1/min
bar
mm^3
bar
km

99.90
3.57
49.16
60.24
277940.00

1/min
bar
mm^3
bar
km

Error occured 2. times at:


Engine speed
fuel pre-supply pressure
Einspritzmenge
RPC rail pressure
Fehler aufgetreten bei
Error occured 3. times at:
Engine speed
fuel pre-supply pressure
Einspritzmenge

199.80
3.47
49.16

1/min
bar
mm^3

RPC rail pressure


Fehler aufgetreten bei

66.27 bar
277940.00 km

Error not present


Sporadic error
Rail-pressure build up
Errorcode: 09 F6 27 03 78 10 07 D9 65 0C 6C 92 10 04 DF 60
0A 6C 92 10 08 D9 60 0B 6C
=============================================================

You might also like