Pilecap Design

For pile group 3P2 + 2PT600


REINFORCEMENT DESIGN
Concrete Grade, Fcu Steel Tensile Strenght, Py Concrete Cover, c Allowable Ecc Compression Pile dia Compression WL Tension Pile dia Tension WL Pilecap Thickness Column size Lever Arm(x axis) Lever Arm(y axis) Design Bending Moment (x axis) Effective Depth, d k z As required As min As provided: = = = = = = = = = = = = = = = = = = = T T 35 460 150 75 900 4700 600 1100 2000 800 1875 1500 10927.5 1786 M/bd2fcu 0.070 0.915 11933.28 2600.00 32 32 12866 Design Bending Moment (y axis) Effective Depth, d k z As required As min As provided: = = = = = = = T T 2227.5 1825 M/bd2fcu 0.017 0.980 2918.51 2600.00 25 0 4908 d mm2/m mm2/m 100 100 Check OK (for top & bottom reinforcement) kN m mm Single reinforced 0.950 d d mm2/m mm2/m 125 125 Check OK MPa MPa mm mm mm kN mm kN mm x mm mm kN m mm Single reinforced 0.915 d 450

b1 b2

1400 1100

PUNCHING SHEAR CHECK


Compression Pile Check Working load of Column Critical Shear Check Column Ult Shear Force, V Shear Stress, v Shear Capacity Critical Shear Check Pile Ult Shear Force, V Shear Stress, v Shear Capacity = = = 7050 1.40 4.73 kN N/mm2 Check OK = = = 14100 3.16 4.73 kN N/mm2 Check OK = 9400 kN (2 compression pile)

Normal Shear Critical Width Shear Stress, v Shear Capacity Tension Rebar 100As/bd 400/d Fcu/30 Vc Av Enchanced Shear = = = = = = = = Tension Pile Check Critical Shear Check Ult Shear Force, V Shear Stress, v Shear Capacity Normal Shear Critical Width Shear Stress, v Shear Capacity Tension Rebar 100As/bd 400/d Fcu/30 Vc Av Enchanced Shear = = = = = = = = 4907.8 0.27 0.22 mm2 0.27 1 = = 3200 0.28 mm N/mm2 = = = 1650 0.48 4.73 kN N/mm2 Check OK 12865.5 0.72 0.22 mm2 0.72 1 = = 2600 1.52 mm N/mm2 (single pile)

1.17 1/3 1/4 1/3 = (0.84(100As/bd) (400/d) (fcu/35) )/1.25 0.63 1200 2d/av x vc 1.89 N/mm2 mm Check: OK

1.17 1/3 1/4 1/3 = (0.84(100As/bd) (400/d) (fcu/35) )/1.25 0.46 1100 2d/av x vc 1.52 N/mm2 mm Check: OK