Three-Phase Central Lighting Inverter System, 10 to 30 kVA

Catalog Number

Trident TRX Series


Comments Type

FEATURES
Application
The Trident TRX Series offers quiet reliable operation for commercial office applications yet is rugged enough for manufacturing environments. The ability to support three-phase AC power improves load efficiency, allows output load balancing and easy building electrical system integration. Precisely controlled system output is suitable for any lighting or critical life safety load up to the full rated output capacity. Technical support is available from a nationwide network of factory-trained technicians.

Operation

AC output provides full lumen output for emergency lighting loads in commercial or industrial applications. Uninterruptible no break transfer provides seamless switching from normal to emergency AC power. Double conversion design completely isolates the line from the load, eliminating the impact of line disturbances and providing more precise output load regulation.

Construction

Electronics and battery cabinets constructed of heavy duty steel, with a medium gray (PMS 877) painted finish. All bolt-on cabinets are equipped with casters and leveling feet. All necessary power cables and control wiring harness are included. Front access battery trays provided for easy maintenance. Top and bottom cable entry provided.

Compliances

UL Listed to Standard 924 (Emergency Lighting) NFPA 101 (Life Safety Code) NFPA 70 (National Electrical Code) Warranty Unit: 1 Year Batteries: 10 Years (1 year full, 9 year pro-rata)

User Interface Panel


Factory start-up supplied standard with all TRX series inverters.

Ordering Guide

TRX
Series

208
Input Voltage 208 208VAC 480 480VAC 600 600VAC

4
Input Conductor 3 3 Wire 4 4 Wire 10 15 20 30

20
Capacity 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW

208
Output Voltage1 208 208VAC 480 480VAC 600 600VAC RSP SFK EXP FWT FTR OWC 485 IRB MBS

RSP
Options Remote Status Panel Seismic Floor Kit Export Package Factory Witness Testing Certified Factory Test Report Open Communications Web Card Open Communications 485 Web Card Intel Slot Relay Board External Maintenance Bypass Switch2

Output voltage must equal input voltage. Consult factory for different input and output voltages. 2 Circuit breakers are standard with all configurations except 208/208 4-conductor; must order MBS to obtain circuit breakers for this configuration. External MBS comes standard with I/O circuit breakers.
1

Three-Phase Central Lighting Inverter System, 10 to 30 kVA specifications

Trident TRX Series


Voltage Distortion: For linear loads, 1% THD. Less than 4% THD for 100% nonlinear loads without kVA/kW derating Phasing Balance: 120 0.5 for balanced load; 120 1 for 100% unbalanced load Frequency Regulation: 0.1% Load Power Factor Range: 0.70 lagging to 0.95 leading without derating Overload: 125% of full load for 10 minutes; 150% for one minute, with true sinusoidal waveform

Input Voltage: 208, 480 or 600VAC, 3- or 4-Wire1 Voltage Range: +10%, -20% Frequency Range: 47-63Hz. Current Distortion: 4% maximum reflected THD at full load Current Limit: 125% of full load input current Walk-ln: 20 seconds to full load Power Factor Range: 0.99 lagging minimum at full load Protective Circuitry: Transient surge (IEC 1000-4-5), LVD, short circuit, current limiting, overload and brown-out Output Voltage: 120/208, 208/208, 277/480, 480/480, 347/600 or 600/600VAC, 3- or 4-Wire1 Voltage Adjustment Range: 5% Voltage Regulation: 1% for balanced load, 2% for 100% unbalanced load Dynamic Regulation: 4% deviation for 100% load step; 1% for loss or return of AC input Transient Response Time: Recover to 1% of steady state within 1 cycle

General Operating Temperature Range: Electrical Cabinet: 0C to 40C (32F to 104F) Battery Cabinet: 20C to 30C (68F to 86F) Relative Humidity: 0-95% non-condensing Operating Altitude: Up to 3,300 ft. (1,000m) without derating Acoustical Noise: Less than 54 dBA typical, measured 3.3 ft. (1 m) from the unit
1

Consult factory for 480VAC application

site planning data


Battery AC Output Mechanical Data System AC AC Input Rating Voltage1 Current Nom. Battery Max. Current No. Of Dimensions - WxDxH Weight kVA kW Input Output Nom. Max. OCPD VDC kW Discharge Nom. OCPD Cabinets inches (mm) Ibs. (kg)

10 8

208 208

28

35

50

288

37A

28 50

51x32.5x63 (1,295x826x1,600) 3,070 (1,393)

Heat Dis. BTU/hr (kWH)

2,800 (0.82)

15 12 20 16 30 24

208 208 208 208 208 208

42 56

53 70

60 80 125 --

288 288 288 --

13 18 26 --

55A 73A 110A 1,3,7

42 60 56 80 83 125 1,3,7 6

2 2 3 --

83x32.5x63 (1,295x826x1,600) 3,970 (1,801) 83x32.5x63 (2,108x826x1,600) 4,870 (2,209) 142x32.5x63 (3,608x826x1,600) 7,170 (3,253) -- --

4,200 (1.23) 5,500 (1.61) 8,300 (2.43) --

83 104 -- 1,3,7

See Notes Below


1

Consult factory for 480VAC applications.

NOTES FOR SITE PLANNING DATA: 1. Input and bypass cables must be run in separate conduit from output cables 2. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are recommended. Neutral conductors to be sized for full capacity per NEC 310-15(B)(4). References are to NEC 2008. 3. Wiring requirements: AC Input: 3-phase, 4-wire, plus ground AC Output: 3-phase, 3- or 4-wire, plus ground 4. All wiring is to be in accordance with national and local electrical codes. 5. Minimum cabinet access clearance: 3 ft. (0.9m) front, 18 in. (457mm) overhead. 6. Top or bottom cable entry through removable access plates. Punch plate to suit conduit size, then replace. 7. Control wiring and power wiring must be run in separate conduit. ADDITIONAL NOTES: If site configuration includes a backup emergency generator, it is recommended that the engine generator set be properly sized and equipped for a UPS application. Generator options would typically include an isochronous governor (generator frequency regulation) and a UPS compatible regulator (generator voltage regulation). Consult generator manufacturer for required generator options and sizing. If site configuration includes an automatic transfer switch, refer to Power Line titled Criteria for Application of Automatic Transfer Switches (ATS) With Uninterruptible Power Supply (UPS) Systems, publication 91K-PLT-48-02. It is also recommended that the transfer switch be equipped with auxiliary contacts for inverter on generator current limit. Consult transfer switch manufacturer for required transfer switch options and sizing. If site configuration requires an external isolated maintenance bypass circuit, it should be noted that utility AC input might not be in phase with the UPS AC output. Consult a Hubbell Lighting, Inc. sales representative or applications engineer. Cabinet Configurations1,2
10 KVA Models 15 and 20 KVA Models 30 KVA Models

63"

51"
1 2

83"

142"

90 minute run time. Contact factory for other run times. Two battery cabinets required on 30 kVA models.

Dual-Lite www.dual-lite.com
A Hubbell Lighting, Inc. brand with representatives offices in principal cities throughout North America. Copyright Hubbell Lighting, Inc., All Rights Reserved Specifications subject to change without notice. Printed in U.S.A. 0601861b 3/11