Professional Documents
Culture Documents
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
1 OF 10
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
H
From Reservoir RW 1 12" 12"-CS-API5L GrB-SCH40 (Existing)
Air Vent
H
To Existing Water Treatment Plant RW 1
G
From Reservoir RW 2 12" From Reservoir
Air Vent
Air Vent
RW 3
12"
12"
12"
Air Vent
16"-CS-API5L GrB-SCH40 (Existing Header) 12" 12" 12" 14" 16" From East Water 16"-CS-API5L GrB-SCH40 (Existing) 14"-CS-API5L GrB-SCH40-Epoxy Coated (New)
Air Vent
E
To 6000 CMD Water Treatment Plant (New) RW 5
D
Blind Flange (New)
RW 4
C
TIE-IN POINT 14" (New)
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
2 OF 10
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
H
From Existing Comp. Air Tank PA 1-uPVC-ASTM D1785-SCH80 PW 1-uPVC-ASTM D1785-SCH80 PW 1-SS304-ASTM A312-SCH80 1-SS304-ASTM A312-SCH80 PA
From Existing Tap Water Pump 1-uPVC-ASTM D1785-SCH80 ALUM To 6000 CMD WTP 1"-uPVC-ASTM D1785-SCH80 1-uPVC-ASTM D1785-SCH80 ALUM To Existing WTP 1"-uPVC-ASTM D1785-SCH80 1-uPVC-ASTM D1785-SCH80 PAC To Existing WTP
Buzzer HMI HLL LLL
HLL NLL
IPC
HLL NLL
IPC
E
4" Vent
LLL
HMI
LLL
4" Vent
LIT
HMI
LI
4" Vent
2"-uPVC
LT HLL Air Filter-Regulator 1"-uPVC
2"x1" 2"-uPVC
Drain
LLL
2"x1" 2"-uPVC
Drain
COAGULANT PUMP
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
3 OF 10
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
PA
1-SS304-ASTM A312-SCH80
1-uPVC-ASTM D1785-SCH80
1-uPVC-ASTM D1785-SCH80
F
HLL NLL LLL HMI IPC HLL NLL LLL HMI IPC
1-uPVC-ASTM D1785-SCH80
1-uPVC-ASTM D1785-SCH80
E
4" Vent
PI 4" Vent
PI
2"-uPVC
2"-uPVC
D
2"x1" 2"-uPVC Unloading From Truck 2"-uPVC
Drain
Drain
2"x1" 2"-uPVC
HICHLOR PUMP
NaOH PUMP
SECONDARY CONTAINMENT 2 STORAGE TANKS AREA Emergency Shower 1 with Eye / Face Wash (Existing)
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
4 OF 10
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
PAC
1-uPVC-ASTM D1785-SCH80
F
1-uPVC-ASTM D1785-SCH80
HLL LLL
HLL LLL
ALUM
Rota meter FI
Rota meter FI
E
2" Vent 1 -uPVC HLL LI PI 1" LT
Drain
FAULT
2" Vent
HMI
LI
PI 1"
FAULT
HS
1 -uPVC HLL
HS LT
Drain
HMI
D
LLL
D
1" 1"
1"
1" LLL
1 -uPVC
1 -uPVC
SECONDARY CONTAINMENT CHEMICALS DOSING AREA Emergency Shower 2 (New) with Eye / Face Wash (For Chemicals Dosing Area)
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
5 OF 10
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
G
-uPVC-ASTM D1785-SCH80 ClO2 From ClO2 Generator (Provisional for ClO2)
Back Press Valve
G
POST-CHLOR To AVGF-Head Tank
E
2" Vent 1"-uPVC HLL LI PI LT
FAULT
LI
PI
V-519
FAULT
HS
HS
LT
D
LLL
Drain
Drain
PRE-CHLORINATION TANK
POST-CHLORINATION TANK
C
SECONDARY CONTAINMENT CHEMICALS DOSING AREA
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
6 OF 10
5
1-uPVC-ASTM D1785-SCH80
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
H
NaOH From NaOH Pump 1-uPVC-ASTM D1785-SCH80 PW From Existing Tap Water Pump 1"-uPVC-ASTM D1785-SCH80 POLYMER To Pipe Flocculator
Buzzer ON
OFF HLL LLL OFF FAULT IPC FI HMI HLL FAULT LLL IPC Rota meter
HS
HMI ON HMI IPC IPC
FI
HS
HMI
E
IPC
ON OFF IPC
LI
PI 1 1"
OFF FAULT
LI
1 "
1 "
PI
FAULT
HMI
HS LT HLL
Drain
HMI
D
LLL
1"
1" LLL
1-uPVC
1"
C
SECONDARY CONTAINMENT CHEMICALS DOSING AREA
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
7 OF 10
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
RW 5
To Pulsator Clarifier
Sampling
IPC
F
PI PT Sampling Sampling
E
PFR-PIPE FLOCCULATOR UNIT
Sampling
PRE-CHLOR From Pre-Chlor Dosing Pump ALUM From Alum Dosing Pump
-uPVC-ASTM D1785-SCH80
1"-uPVC-ASTM D1785-SCH80
PAC From PAC Dosing Pump POLYMER From Polymer Dosing Pump
1"-uPVC-ASTM D1785-SCH80
1"-uPVC-ASTM D1785-SCH80
-uPVC-ASTM D1785-SCH80
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
8 OF 10
3
REV
2
REVISIONS DESCRIPTION For Bidding DATE
1
APPROVED
-uPVC-ASTM D1785-SCH80
LI LT
RW 5+
IPC
KS
HS
HMI
HS
KS LI AVGF-HEAD TANK
HMI IPC
E
3" 3"
E
ATM. VENT MH
LT
NLL
HMI HMI IPC HMI
12"
LLL
KS
HS
HS
KS 6"
6" 3"
IPC
HMI
6"
HMI
6"
HMI
3" HS
M
IPC
HS
M
IPC
HS
M
6" Spare for Air Scour 6" Spare for Manual BW 6"
C
BW AUTOMATIC VALVELESS GRAVITY FILTER To Drainage System (Existing)
PULSATOR CLARIFIER
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
9 OF 10
3
REV 0 For Bidding
2
REVISIONS DESCRIPTION DATE
1
APPROVED
HMI
HMI
IPC
FE
LE
ATM. VENT
HLL
E
NLL
D
LLL
PW
Existing
C
CLEAR WATER TANK 4 (Existing)
SIZE
FSCM NO
DWG NO
REV
SCALE
NTS
SHEET
10 OF 10