You are on page 1of 2

Performance Test Data for Interline 399

Epoxy Phenolic Tank Lining Test Type Cathodic Disbondment Test Method ASTM G42 - "Cathodic Disbondment of Pipeline Coatings Subjected to Elevated Temperature" Specification Details 2 x 100m dft applied directly to Sa2 blasted steel. Typical Results No coating disbondment following 30 days exposure at 60C, 80C and 90C

Cold Wall Simulation

Internal Test Method : Hot Side = 50C ; Cold Side = 20C

2 x 125m dft applied directly to Sa2 blasted steel.

No blistering, cracking, rusting , adhesion loss and underfilm corrosion following 648 hours exposure to cold wall.

Condensation

ISO 6270 - "Resistance to continuous condensation @ 35C"

2 x 100m dft applied directly to Sa2 blasted steel.

No film defects following 4,200 hours exposure.

Immersion

ISO 2812 Part 2 "Resistance to water immersion @ 40C"

2 x 100m dft applied directly to Sa2 blasted steel.

No film defects following 4,200 hours exposure.

Immersion

NACE TM-01-74 "Methods for the evaluation of linings for immersion service 90C deionised water"

2 x 100m dft applied directly to Sa2 blasted steel. (stoved & unstoved @ 220C)

No blistering , rusting , cracking or flaking following 504hrs exposure.

Adhesion

ISO 4624 - "Pull-off test for adhesion" using portable adhesion testers

2 x 100m dft applied directly to Sa2 blasted steel.

Not less than 10MPa (1450psi) when using a PAT Model GM01 hydraulic adhesion tester on 5mm thick steel.

03 December 2002

Page 1 of 2

All representation and statements concerning the product(s) in this report are accurate to the best of our knowledge. Any statements herein are not intended to be specific recommendations or warranties of any product, combination of products or fitness for purpose

Interline 399

Test Type Impact

Test Method ASTM D2794 "Resistance to the Effects of Rapid Deformation (Impact)"

Specification Details 2 x 100m dft applied directly to Sa2 blasted steel.

Typical Results Direct Impact Resistance - 2 Joules.

03 December 2002

Page 2 of 2

All representation and statements concerning the product(s) in this report are accurate to the best of our knowledge. Any statements herein are not intended to be specific recommendations or warranties of any product, combination of products or fitness for purpose

Interline 399