You are on page 1of 2

Performance Test Data for Interline 850

Epoxy Phenolic Tank Lining Test Type Cathodic Disbondment Test Method ASTM G8 - "Cathodic Disbonding of Pipeline Coatings" , Method A Specification Details 2 x 125m dft applied directly to Sa2 blasted steel. Typical Results Typically less than 7mm disbondment following 30 days exposure.

Condensation

ISO 6270 - "Resistance to continuous condensation @ 35C"

2 x 150m dft applied directly to Sa2 blasted steel.

No film defects following 1 year exposure.

Immersion

ISO 2812 Part 2 "Resistance to water immersion @ 40C"

2 x 150m dft applied directly to Sa2 blasted steel.

No film defects following 1 year exposure.

Abrasion

ASTM D4060 "Abrasion Resistance of Coatings via the Taber Abraser"

2 x 125m dft applied directly over abraded steel.

Average of 86mg weight loss per 1000 cycles using CS10 wheels and a 1Kg loading.

Adhesion

ISO 4624 - "Pull-off test for adhesion" using portable adhesion testers

2 x 125m dft applied directly over abraded steel.

Not less than 10MPa (1450psi) when using a PAT Model GM01 hydraulic adhesion tester on 5mm thick steel. An average of 0.8% elongation of the coating is achieved prior to fracture.

Elongation @ Break

ASTM D2370 - "Tensile & Elongation Properties of Coatings"

1 x 125m dft "free film"

08 October 2001

Page 1 of 2

All representation and statements concerning the product(s) in this report are accurate to the best of our knowledge. Any statements herein are not intended to be specific recommendations or warranties of any product, combination of products or fitness for purpose

Interline 850

Test Type Impact

Test Method ASTM D2794 "Resistance to the Effects of Rapid Deformation (Impact)"

Specification Details 2 x 125m dft applied directly to Sa2.5 blasted steel.

Typical Results Direct Impact Resistance - 2 Joules.

Tensile Strength

ASTM D2794 "Resistance to the Effects of Rapid Deformation (Impact)"

1 x 125m dft "free film"

An average of 5MPa (725psi) is required to achieve fracture of the coating.

08 October 2001

Page 2 of 2

All representation and statements concerning the product(s) in this report are accurate to the best of our knowledge. Any statements herein are not intended to be specific recommendations or warranties of any product, combination of products or fitness for purpose