Configuration and Commissioning NEC iPasolink. TP Vega Project


Commissioning Print Screen

Internal Only

LOGIN TO iPasolink Equipment.

User Name: Admin Password: 12345678

Internal Only

Main Window

Internal Only

Equipment Configuration

Click on Setup to start configuration.

Internal Only

NE Name

Type NE name here and use same format. Dont write link ID .Only mention station ID e.g: site_id-iPaso (200/400/1000)-1 (1 represent the sequence number of IDU on same station. If there are two IDU write 1 on upper IDU and write 2 on second IDU and so on.)

Internal Only

Pluggable Module Detection

If new modem card or any other card used, click on Auto Detect or select manually from the drop down list. Otherwise you cannot use new cards.

Internal Only

Link Configuration

Select link configuration from the drop down list. Note: For 1+1 link configuration make sure the license is available otherwise you cannot select 1+1 configuration.

Internal Only

Click OK button after finish.

Internal Only

Radio Configuration:

In Radio configuration Menu, Click on Setup

Internal Only

ODU Information:

Make sure that ODU information is not invalid here. If it is invalid check ODU power, IF cable, IF Connectors etc.

Set Channel spacing as per link budget.

Internal Only

Modulation Scheme:

Select Modulation as per link budget.

Internal Only

Radio Mode:

Select Radio Mode:

Internal Only

Frequency:

Set frequency as per link budget:

Internal Only

Press OK button after finish:

Internal Only

Modem Port Setting

Click on Provisioning->Modem Function Setting->Modem Port Setting.

Internal Only

Link Name/ID:

Click on MODEM Slots and type LINK ID as per actual scenario. We can identify the links with the this setting. So this is mandatory.

Internal Only

Transmit Power Setting:

Click on Tx Power Setting to set the radio transmit power.

Internal Only

Tx Power Setting:

Click on desired link MODEM slot and set the power as per link budget..

Internal Only

Metering:

Click on Metering-> Current Metering Click on MODEM to check the RSL change during Alignment.

Internal Only

Comments:

After aforementioned steps we can start the alignment. Keep watching RSL at Metering and lock the antennas at more than 3db of required RSL given in link budget.

Internal Only

NMS Configuration for Root NE:

Click on Network Management Configuration and then click on General Setting. Click on setup to set the IP.

Internal Only

General Setting.

Set IP, Subnet Mask and GW as per given DCN plan and check connect NMS port to NMS to yes for root NE which is connected with NEC server through router.

Internal Only

General Setting (Detailed)

Click on Setup to start configuration.

Internal Only

Inband Management & Ethernet Port Setting

Set Inband Management to not used

Set NMS port Used

Internal Only

NE Branch Setting

Set branch number to 2 branches Default Gateway is same as the GW given in General Setting. Therefore no need to change.

Internal Only

NMS Branch IP Setting.

Click on 1 to set branch 1 IP. Branch 1 is NMS and the IP given in General Setting will appear automatically there so no need to change.

Internal Only

NE Branch Setting:
Click on 2 and set NE branch IP and subnet mask as per given DCN plan. Note: All MODEM with this IDU will automatically get Branch 2 IP.

Check yes for Connect to NMS port and check any for Protect LCT connection.

Internal Only

Routing Setting.

No need to change Routing Setting. Gateway will automatically appear here when General Setting is finished.

Internal Only

NMS Setting Service Setting


Click on User Account/ Security Setting->Security Management>Service Status Setting.

Service Status Summary. Should be same as here.

Internal Only

SNMP Setting.
Click on SNMP and enable SNMP V1, SNMP V3. Set UDP port to 161.

Internal Only

SNMP Community
Click on SNMP Community and set: Community Name: public Access Level: Admin. Access Control: Enable Service IP Address: 0.0.0.0 Subnet Mask: 255.255.255.255

Internal Only

SNMP Trap Entry and NTP


SNMP Trap Entry : No change. NTP Should be in Running Status and parameters should be same as given here.

Internal Only

NTP Server Address and FTP


SNMP Service Address : No change. FTP Should be in Running Status and parameters should be same as given here.

Internal Only

SFTP, HTTP and HTTPS


SFTP : Stopped HTTP: Running and TCP port is 80. HTTPS: Stopped

Internal Only

Normal NE NMS Configuration:

For Normal NE we use the same steps in General Setting but set Connect NMS port to NMS to NO.

Internal Only

General Setting (Detailed)

Set Inband Management to not used

Set NMS port Used;;

Internal Only

NE Branch Setting:

Set Branch number to 1 Default GW and branch 1 IPs will be same as in general Setting. No need to change here.

Set NMS port to NO and Restrict LCT connection to Any

Internal Only

Equipment Cascade setting

If there are two IDUs in station then for DCN we need to cascade setting for the two IDUs. Click on Equipment Cascade Setting and then click on Setup.

Internal Only

Equipment Cascade Setting:

Select Number of NEs in station: 2 for two IDUs Own Cascade ID: 1 is for the same IDU connected with your laptop. 2 is for other IDU on the same station. Set the IP of other IDU and click OK.

Internal Only

Comments

Service Status setting in Normal NE is same as root NE. So do the same steps for normal NE. In a hub if there are two IDUs use LAN cable between NMS port to NMS port. If in any case NMS port is used we can configure first Eth Port as NE management.

Internal Only

Ethernet Function Setting:

Click on Bridge Setting and then click on Modify .

Internal Only

Bridge Setting:

Set Aging On FDB Aging Time:300s GbE Max Frame Size: 2000 bytes FE Max Fame Size:1522bytes Vlan Mode:802.1Q (Mandatory) Default VLAN ID1 Default VLAN TPID: 8100

Internal Only

Ethernet Ports Enable/Disable

Ethernet port can be enable or disable from Eth Port Setting. Click on desired port to enable or disable.

Internal Only

Ethernet Port Speed:

If Ethernet port enabled its speed should be set auto.

Internal Only

VLAN Creation:

Example: Site MMN012-MMN008-MMN751_BSC

We want to create VLAN for ZTE SDR. First we enable eth port-1 for SDR. Set the station ID in port name.

Internal Only

VLAN Setting: Example site:MMN012

Click on VLAN Setting and then click on VLAN List.

Internal Only

VLAN List

Click on Add VLAN. Type VLAN id and VLAN Service Name. Type site id in VLAN service Name.

Internal Only

VLAN Assignment to Eth Port:

Click on Main Board Port01 to assign a VLAN from VLAN list:

Internal Only

VLAN Assignment:

Set port mode trunk and check the planned VLAN ID from list.

Internal Only

VLAN assignment to MODEM (radio link) Port:

Click on Main Board Port01 to assign a VLAN from VLAN list:

Internal Only

VLAN Assignment:

Set port mode trunk and check the planned VLAN ID from list.

Internal Only

VLAN Main Page after Creation:

After VLAN creation the VLAN IDs will appear against each port like here:

Internal Only

Far End MMN008 VLAN Creation:

First of all VLAN id of Site MMN012 should be added in VLAN list of MMN008.:

Internal Only

VLAN Assignment of Modem (Radio Link) Port

Assign the VLAN of Site MMN012 to the link MMN012MMN008 Modem. Use the same procedure as described in previous slides:

Internal Only

VLAN Assignment to other port facing MMN751-BSC

As there are two IDU on MMN008 station and our example link is in second IDU but the link with BSC is in first IDU. Therefore we use Ethernet Ports and a physical LAN cable between two IDUs. So we assign VLAN to eth port02 which is connected with first IDU.

Internal Only

MMN008 facing MMN751 IDU.

Assignment of VLAN of MMN012 coming from other IDU via eth port. Assignment of VLAN of MMN012 to the link facing BSC_MMN75 1.

Internal Only

BSC Site MMN751

At MMN751 VLAN for MMN012 should be added in VLAN list.

Internal Only

VLAN assignment to Link facing MMN008

Assign the VLAN of MMN012 to Modem Port MMN008-MMN751.

Internal Only

VLAN Assignment to LAG Ethernet Group:

At BSC site VLANs of all cluster Sites are assigned to two GbE Optical Ports. Normally 3rd &4th port is used in iPaso. We set LAG function over these ports. These ports are physically connected with PTN via fiber cables and then PTN is connected with BSC. So we assign VLAN of our example site MMN012.

Internal Only

Tips for VLAN Configuration:


VLAN is used for ZTE SDR in Telenor Vega Project. We assign VLAN to ZTE SDR and same VLAN is assigned to NEC iPasolinks ethernet and modem ports from terminal site to up till BSC site. In a hub site we simply assign the VLAN to MODEM facing terminal site and to MODEM facing BSC site. Same rule of thumb is used for all the hub in the path. If there are two IDUs in a hub we use physical LAN cable between two IDU and assign all the VLAN coming from sites to both end IDUs eth ports. VLAN mode is always trunk

Internal Only

Equipment Clock Setting:

Use this setting for Root NE. Root NE is always master and all other NEs are salve in iPaso Network.

Internal Only

Equipment Clock Setting: Slave

For normal NE use this Clock Setting. Normal NE is always Slave. Note: In a hub if there are two IDUs then the first IDU will be slave and second IDU will be master. All other IDU connected with second IDU will be slave.

Internal Only

Ethernet QoS Setting:

Click on QoS/ Classification Setting. Click on classification mode.

Internal Only

Equipment Based QoS Mode:

Set Equipment Based QoS mode.

Internal Only

Select Profile No.

Click on Select Profile No.

Internal Only

Profile 0.

Select the profile no 0 to set planned QoS parameters.

Internal Only

Profile 0 configuration:

Select the profile no 0 to set planned QoS parameters. Click on entry 1 to set the Priority.

Note: By default required setting for Profile 0 is available in iPasolink. No need to change profile 0 setting.

Internal Only

Profile 1 Configuration.

Select the profile no 1 to set planned QoS parameters. Click on entry 1 to set the Priority.

Internal Only

Profile 1 Setting:

Set the classify field, classify Priority and Classify internal Priority as per given Plan.

Click on entry no one by one as per required entries and set classify priorities.

Internal Only

Ingress Setting:

No need to set Ingress Setting.

Internal Only

Port Setting:

No need to change Port Setting.

Internal Only

Link Aggregation.

Click on Eth Port and Enable Port 3 and port 4 optical ports. Set the name of ports as the given ports in PTN.

Internal Only

Link Aggregation

Click Link aggregation Setting and click on Add Lag

Internal Only

LAG configuration.

Select ETH GRP1, Set the Name, Mode: Static Interval: Short Distribution Rule: L2

Set LAG on Port 3 and Port 4 as given here.

Internal Only

Link Aggregation Status:

After LAG creation if the fiber cables connected with PTN then the status should be up. Example is here.

Internal Only

VLAN assignment to LAG

Assign All VLAN from VLAN list to LAG . Example is given here.

Internal Only

VLAN assignment to LAG.

Internal Only

Thank you.

Yasir Masood Microwave Expert ZTE (Pvt) Ltd Pakistan