CONICALTYPESTRAINERS
FCO2
M.Ghisoni
Pag.1/3
SIZES
GENERALNOTESTRAINERSPRODUCTION
Temporaryfilter,inline,suitableforfilteringfluidsorgases,designedfor
briefperiodsofuse,suchasthefinetuningandstartupofaplant.
Installedtoremoveanycoarse detritussuchasrags,electrodes,deposits
andrustleftinsidethepipes.
Comprisingarolledperforatedsheetintheformofaconewelded
perpendicularlytoaringjoint,theconicalfilteriseasytoinstalland
replacebecauseitispositionedbetweentwoflangesofapipe.
Filtersuitableforhighpressures,easytomaintainandreplaceandcapable
offiltrationofmorethan200%oftheinletarea.
OPENAREARATIO=
100xMeshOpenAreaxScreenArea
Inletarea
SIZES
23468101216182024
CONNECTIONS
Flanged
FLG
ANSIB16.5
GENERALNOTESTRAINERSSTANDARDPRODUCTION
FLOW
InternalFlow
ExternalFlow
REINFORCING
Withoutreinforcing
Withinternalreinforcing Withexternalreinforcing
CONNECTION
ConnectionRForFF
ConnectionRJ
Blu Zac srl reserves the right to carry-out any necessary modification without prior notice
[Digitare il testo]
Doc.n:10I131648
Rev.00
Date:13/12/2010
CONICALTYPESTRAINERS
FCO2
Size
(inches)
D
H
L
S
A
B
Weight
(kg)
M.Ghisoni
Pag.2/3
2.1/2
10
12
14
16
18
20
24
73
60
70
3
32
20
92
80
70
3
46
25
105
100
70
3
55
25
127
120
70
3
70
35
157
150
80
3
94
50
216
230
100
5
143
80
270
300
100
5
190
120
324
350
110
5
240
150
381
400
110
5
285
180
412
470
120
5
315
180
470
550
130
8
360
225
534
700
130
8
405
230
584
800
140
8
450
230
692
900
150
8
540
230
0,5
0,5
1,5
3,5
15
18
17
20
Note1:Dimension:areinmillimeters(mm)
Note2:RJconnectionareaccordingtoASMEB16.20(seebelow)
1.1/2"
2"
2.1/2"
3"
4"
6"
8"
10"
12"
14"
16"
18"
20"
24"
150RJ
R19
R22
R25
R29
R36
R43
R48
R52
R56
R59
R64
R68
R72
R76
300RJ
R20
R23
R26
R31
R37
R45
R49
R53
R57
R61
R65
R69
R73
R77
600RJ
R20
R23
R26
R31
R37
R45
R49
R53
R57
R61
R65
R69
R73
R77
DIMENSIONTOLLERANCE
DIMENSION*
SIZE
1/2"to2.1/2"
3"to4"
6"to8"
10"to18"
20"to24"
*S,SF,A,HandH1
areinmillimeters(mm)
B
H&L
1
1
2
2
3
1
2
3
5
8
R66
R67
R70
R71
R74
R75
R78
R79
INSTALLATIONINSTRUCTION
1) Installthebasketinthebodyandbetweenthetwo
flanges
2) Positionthegasketandtheflangeconnection,
3) Thenscrewthestudsandnutsoftheflangeinthe
correctposition
MAINTENACEINSTRUCTIONS
1) Unscrewcoverstudsandnuts,
thenremovetheconnectionflangeandgasket.
2) Removethestrainerandcleanorreplaceit.
3) Whenyoureinstallit,useanewgasket.
Blu Zac srl reserves the right to carry-out any necessary modification without prior notice
[Digitare il testo]
Doc.n:10I131648
Rev.00
Date:13/12/2010
CONICALTYPESTRAINERS
FCO2
M.Ghisoni
Pag.3/3
POS
DESCRIPTION
MATERIALS
MATERIALS
MATERIALS
MATERIALS
SPARES
1
2
3
4
5
6
Ring
Handle
PerforatedPlate
Mesh
Frame
Centerring
ASTMA240TP316
ASTMA240TP316L
ASTMA240TP304
ASTMA240TP304L
ASTMA240TP316
ASTMA240TP316L
ASTMA240TP304
ASTMA240TP304L
ASTMA240TP316
ASTMA240TP316L
ASTMA240TP304
ASTMA240TP304L
7
8
AISI316
AISI316L
AISI304
AISI304L
ASTMA182F316
ASTMA182F316L
ASTMA182F304
ASTMA182F304L
ASTMA240TP316
ASTMA240TP316L
ASTMA240TP304
ASTMA240TP304L
RingRJ
ASTMA182F316
ASTMA182F316L
ASTMA182F304
ASTMA182F304L
SpacerRing
ASTMA240TP316
ASTMA240TP316L
ASTMA240TP304
ASTMA240TP304L
MATERIALS
MATERIALS
MATERIALS
MATERIALS
SPARES
ASTMA240UNSS31803 ASTMA240UNSS32750
HASTELLOY
MONEL
ASTMA240UNSS31803 ASTMA240UNSS32750
HASTELLOY
MONEL
POS
DESCRIPTION
1
2
3
4
5
6
Ring
Handle
PerforatedPlate
Mesh
Frame
Centerring
RingRJ
SpacerRing
HASTELLOY
MONEL
UNSS31803
UNSS32750
HASTELLOY
MONEL
ASTMA182F51
ASTMA182F53
HASTELLOY
MONEL
HASTELLOY
MONEL
HASTELLOY
MONEL
HASTELLOY
MONEL
ASTMA240UNSS31803 ASTMA240UNSS32750
ASTMA240UNSS31803 ASTMA240UNSS32750
ASTMA182F51
ASTMA182F53
ASTMA240UNSS31803 ASTMA240UNSS32750
Note1:OtherMaterialsandDimensionsonRequest
Note2:Detail7and8areoptionalifrequiredbyclient.
Note3:Detail5isoptional;itisnecessaryforguarantytheresistanceonlywhenthedifferentialpressureisgreaterthanvalueof1bar.
Note4:Detail6isoptional;itisnecessaryforguarantytherigidityonlywhenthedimensionHisgreaterthan1000mm.
ORDERCODE
i.e.FCO22150RFM20O1AISI304