You are on page 1of 1

NTPC

QUALITY SYSTEM RECORDS

KORBA
REV : 1.2 DATE : 16/ 01 /03 PAGE : 1 OF 1

TITLE : EHC.BALANCING VOLTAGE ADJUSTMENT.

REC No : C&I / TG 0 / R-1 JOBS UNIT NO: 1. 2. 3. 4.

REF. NO. C&I / TG-0 / WI-1 COMPLIANCE

PTW of PFW type with EHC rack HP/IP secondary fluid line isolation valves in position is obtained. The balancing voltage across the coil is measured after removing the cover by giving copy in put voltage to the coil and is recorded. The plunger coil is rotated till -1.0 V appears across it, and the mounting bolts are tightened and the value is recorded. The input voltage is varied at the copy input and the values are recorded. INPUT VOLTAGE 1.0 Volts 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Volts Volts Volts Volts Volts Volts Volts Volts Volts BALANCING VOLTAGE Copy I / P V =

5.

PTW is cancelled after normalising the cover of the ECH.

AREA ENGINEER NAME : DESIGNATION: SIGNATURE : DATE :

JOB CARRIED OUT BY NAME : DASIGNATION: SIGNATURE : DATE :