Pushover analysis of 5-storey clinic building at Bangladesh secretariat

4000

4000

Base shear (kN)

Base Shear (kN)

3000

3000

2000

2000

1000

1000

0 0 50 100 Roof displacement (mm) 150 200

0 0 50 100 Roof displacement (mm) 150 200

(a)

(b)

Figure 1: Pushover Response curve, (a) By using SAP 2000, V15.0, (b) By using software Seismostruct

4000

Base shear (kN)

3000

Roof topr 4th f loor

2000

3rd f loor 2nd f loor 1st f loor

1000

0 0 50 100 Displacement (mm) 150

Figure 2: Pushover Response curve By using SAP 2000, V15.0

Figure 3: Collapse mechanism of clinic building


5

Storey

0 0 1 2 3 Inter-storey Drif t (%)

Figure 4: Inter-storey drift distribution of clinic building

0.5

Spectral Acceleration, Sa(g)

0.25

0 0 0.5 1 1.5 Period (Sec) 2 2.5 3

Figure 5: Spectral acceleration (BNBC-1993, Zone-2, Soil profile-2)

Figure 6: Performance evaluation of clinic building (ATC-40)

Figure 7: Performance evaluation of clinic building (FEMA-356)

Summary: The results of pushover analysis indicated that the performance of the clinic building is satisfactory globally under BNBC-1993 spectral acceleration. To evaluate the performance soil type S2 and Zone 2 of BNBC-1993 is considered here. The performance point base shear is 2375 kN and roof displacement is 45mm as per ATC-40. The performance point base shear is 2524 kN and roof displacement is 50mm as per FEMA-356. However from the hinge formation (Figure-3) at different element indicates some retrofitting works required at the lower end of bottom storey column.