737-300/400 ELECTRICAL

PT. METRO BATAVIA Directorate of Operational

Main Menu

Quit

Next

Slide 1 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
NORMAL POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
ALTERNATE POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 2 of 90

EXTERNAL AC RECEPTACLE F V
BUS PROTECTION PANEL

737-300/400 Electrical Schematic

GENERATOR BUS 1

GENERATOR BUS 2

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The generator busses can receive power from three different sources. One possibility is to utilize ground power.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 3 of 90

EXTERNAL AC RECEPTACLE F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A ENGINE DRIVEN GENERATOR 2 V

GENERATOR BUS 1

GENERATOR BUS 2

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

A second possibility is to utilize the respective engine driven generators.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 4 of 90

EXTERNAL AC RECEPTACLE F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The third and final possibility is to utilize the APU generator.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 5 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

Ground power also powers the external AC bus.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 6 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

GROUND SERVICE BUS

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The ground service bus can receive power from two different sources. The first possibility is generator bus 1.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 7 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

GROUND SERVICE SWITCH

GROUND SERVICE BUS

See picture of ground service switch

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The second possibility is the ground power (via the ground service switch).

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 8 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

GROUND SERVICE SWITCH

GROUND SERVICE BUS

MAIN BUS 1

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The only power source to main bus 1 is generator bus 1.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 9 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The normal power source to transfer bus 1 is generator bus 1.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 10 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The alternate power source to transfer bus 1 is generator bus 2.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 11 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The normal power source to transfer bus 2 is generator bus 2.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 12 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The alternate power source to transfer bus 2 is generator bus 1.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 13 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

LEGEND
AC POWER

DC POWER

1
NORMAL POWER SOURCE

The only power source to main bus 2 is generator bus 2.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 14 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

LEGEND
AC POWER

DC POWER

AC STANDBY BUS

1
NORMAL POWER SOURCE

The normal power source to the AC standby bus is transfer bus 1.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 15 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

A
LEGEND
AC POWER

DC POWER

AC STANDBY BUS

1
NORMAL POWER SOURCE

Transfer bus 1 powers TR1.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 16 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

A
LEGEND
AC POWER

DC POWER

AC STANDBY BUS

1
NORMAL POWER SOURCE

Transfer bus 2 powers TR2.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 17 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC POWER

AC STANDBY BUS

1
NORMAL POWER SOURCE

Main bus 2 powers TR3.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 18 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

DC POWER

AC STANDBY BUS

1
NORMAL POWER SOURCE

TR1 powers DC bus 1.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 19 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

DC BUS 2

DC POWER

AC STANDBY BUS

1
NORMAL POWER SOURCE

TR2 powers DC bus 2.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 20 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

TR3 DISCONNECT RELAY

DC BUS 2

DC POWER

AC STANDBY BUS

1
NORMAL POWER SOURCE

TR1 and TR2 are connected via the TR3 disconnect relay.
PT. METRO BATAVIA Directorate of Operational

2
ALTERNATE POWER SOURCE

Slide 21 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

TR3 DISCONNECT RELAY

DC BUS 2

DC POWER

AC STANDBY BUS

BATTERYBUS V

1
NORMAL POWER SOURCE

The normal power source to the battery bus is TR3.


PT. METRO BATAVIA Directorate of Operational

2
ALTERNATE POWER SOURCE

Slide 22 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

TR3 DISCONNECT RELAY

DC BUS 2

DC POWER

AC STANDBY BUS

BATTERYBUS V

1
NORMAL POWER SOURCE

TR3 is a backup to TR1 and TR2. TR1 and TR2 do not backup TR3.
PT. METRO BATAVIA Directorate of Operational

2
ALTERNATE POWER SOURCE

Slide 23 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS BATTERYBUS V

DC POWER

AC STANDBY BUS

1
NORMAL POWER SOURCE

The normal power source to the DC standby bus is DC bus 1.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 24 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

BATTERYBUS V

1
NORMAL POWER SOURCE

The alternate power source to the DC standby bus is the battery bus.

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 25 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1
GROUND SERVICE SWITCH

2 power source 2 The alternate to the AC standby bus is the battery busTRANSFER via the TRANSFER BUS BUS RELAY 1 RELAY 2 static inverter.
MAIN BUS 1 TRANSFER BUS 1 TRANSFER BUS 2 MAIN BUS 2

GROUND SERVICE BUS

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
NORMAL POWER SOURCE

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 26 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1
GROUND SERVICE SWITCH

2 2 the battery The normal power source to charger is the ground service bus. TRANSFER BUS TRANSFER BUS
RELAY 1 RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
NORMAL POWER SOURCE

V
BATTERY CHARGER

2
ALTERNATE POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

PT. METRO BATAVIA Directorate of Operational

Slide 27 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1
GROUND SERVICE SWITCH

2 The alternate power source 2 to the battery charger is main bus 2. TRANSFER BUS TRANSFER BUS
RELAY 1 RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
NORMAL POWER SOURCE

V
BATTERY CHARGER

2
ALTERNATE POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

PT. METRO BATAVIA Directorate of Operational

Slide 28 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1
GROUND SERVICE SWITCH

2 power source 2 The alternate to the battery TRANSFER BUS bus is the hot battery bus. TRANSFER BUS
RELAY 1 RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
NORMAL POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS

2
ALTERNATE POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

PT. METRO BATAVIA Directorate of Operational

Slide 29 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1
GROUND SERVICE SWITCH

2 battery charger 2 When needed, the re-charges the battery. TRANSFER BUS TRANSFER BUS
RELAY 1 RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
NORMAL POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS

APU START BATTERY CHARGER CUTOUT RELAY

See picture of battery

A
BATTERY

2
ALTERNATE POWER SOURCE

PT. METRO BATAVIA Directorate of Operational

Slide 30 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1
GROUND SERVICE SWITCH

2 charger or the 2 Either the battery battery can provide bus. BUS TRANSFER BUS power to the hot battery TRANSFER
RELAY 1 RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
NORMAL POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
ALTERNATE POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

PT. METRO BATAVIA Directorate of Operational

Slide 31 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1
GROUND SERVICE SWITCH

GROUND SERVICE BUS

2 In the case of a dead battery, 2 an external DC power source may be plugged into theBUS TRANSFER BUS TRANSFER RELAY 1 RELAY 2 external DC receptacle, which in turn MAIN BUS 1 TRANSFER BUS 1 BUS 2 replaces the battery as a TRANSFER power source. T
R1 A

MAIN BUS 2

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
NORMAL POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS

APU START BATTERY CHARGER CUTOUT RELAY

See picture of external DC receptacle

A
BATTERY

2
ALTERNATE POWER SOURCE

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 32 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

This concludes the review of the Electrical Schematic. The remainder of the presentation ENGINE DRIVEN ENGINE DRIVEN APU GEN GENERATOR 1 will discuss the electrical system in greater detail. Click Next to continue. GENERATOR 2
GENERATOR BUS 1 GENERATOR BUS 2

1
GROUND SERVICE SWITCH

2 The only power source to the 2 switched hot TRANSFER BUSbattery bus is the battery. TRANSFER BUS
RELAY 1 RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
NORMAL POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
ALTERNATE POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 33 of 90

AC/DC Metering Panel

PT. METRO BATAVIA Directorate of Operational

Slide 34 of 90

AC/DC Metering Panel


DC AMPS (DC Ammeter): Indicates current of source selected by DC meter selector.

PT. METRO BATAVIA Directorate of Operational

Slide 35 of 90

AC/DC Metering Panel

DC VOLTS (DC Voltmeter): Indicates voltage of source selected by DC meter selector.

PT. METRO BATAVIA Directorate of Operational

Slide 36 of 90

AC/DC Metering Panel


AC Frequency Meter (cycles per second): Indicates frequency of source selected by AC meter selector.

PT. METRO BATAVIA Directorate of Operational

Slide 37 of 90

AC/DC Metering Panel


AC Voltmeter: 130 V scale Indicates voltage of source selected by the AC meter selector. 30 V scale Indicates residual voltage of generator selected when RESID VOLTS switch is pressed.

PT. METRO BATAVIA Directorate of Operational

Slide 38 of 90

AC/DC Metering Panel

DC Meter Selector: Selects the DC source for the DC voltmeter and DC ammeter indications.

PT. METRO BATAVIA Directorate of Operational

Slide 39 of 90

AC/DC Metering Panel

AC Meter Selector: Selects the AC source for the AC frequency meter and AC voltmeter.

PT. METRO BATAVIA Directorate of Operational

Slide 40 of 90

BAT Switch
BAT (Battery) Switch: ON Provides power to switched hot battery bus and battery bus. Energizes relays to provide automatic switching of standby electrical system to battery power with loss of normal power. BAT (Battery) Switch: OFF Removes power from the battery bus and switched hot battery bus when operating with normal power sources available. Removes power from battery bus, switched hot battery bus, DC standby bus, static inverter, and AC standby bus when the battery is the only power source.
Slide 41 of 90

PT. METRO BATAVIA Directorate of Operational

GALLEY Power Switch


GALLEY Power Switch: ON Electrical power is supplied to galleys when both AC generator busses are powered. OFF Removes electrical power from galleys.

PT. METRO BATAVIA Directorate of Operational

Slide 42 of 90

RESID VOLTS Switch


RESID VOLTS Switch: PRESS 30V scale of AC voltmeter indicates residual voltage of generator selected. Caution: If residual voltage is checked with respective generator online, the reading is invalid and damage to the voltmeter may result.

PT. METRO BATAVIA Directorate of Operational

Slide 43 of 90

Normal Indications
DC Metering Panel

Normal indications with STBY PWR selected are:

0 (zero) DC amps.

Depends on amount of voltage demanded from the DC standby bus. Normally 22 - 30 DC volts.

PT. METRO BATAVIA Directorate of Operational

Slide 44 of 90

Normal Indications
DC Metering Panel

Normal indications with BAT BUS selected are:

0 (zero) DC amps.

Depends on amount of voltage demanded from the battery bus. Normally 22 - 30 DC volts.

PT. METRO BATAVIA Directorate of Operational

Slide 45 of 90

Normal Indications
DC Metering Panel

Normal indications with BAT selected are:


If battery being charged: Needle deflection to right. If battery being discharged: Needle deflection to left. If battery in steady state: 0 (zero) DC amps. Depends on amount of voltage demanded from the hot battery bus. Normally 22 - 30 DC volts.

PT. METRO BATAVIA Directorate of Operational

Slide 46 of 90

Normal Indications
DC Metering Panel

Normal indications with TR1 selected are: Depends on amount of amps being produced by TR1.

Depends on amount of voltage demanded from the DC bus 1.

PT. METRO BATAVIA Directorate of Operational

Slide 47 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 48 of 90

Normal Indications
DC Metering Panel

Normal indications with TR2 selected are: Depends on amount of amps being produced by TR2.

Depends on amount of voltage demanded from DC bus 2.

PT. METRO BATAVIA Directorate of Operational

Slide 49 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 50 of 90

Normal Indications
DC Metering Panel

Normal indications with TR3 selected are: Depends on amount of amps being produced by TR3.

Depends on amount of voltage demanded from TR3.

PT. METRO BATAVIA Directorate of Operational

Slide 51 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 52 of 90

Non-Normal Indications
DC Metering Panel

Indications of an inoperative TR1 are:

0 (zero) DC amps.

Depends on amount of voltage demanded from DC bus 1. Power to DC bus 1 is now from TR2 and TR3 (via the TR3 disconnect relay).

PT. METRO BATAVIA Directorate of Operational

Slide 53 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 54 of 90

Non-Normal Indications
DC Metering Panel

Indications of an inoperative TR2 are:

0 (zero) DC amps.

Depends on amount of voltage demanded from DC Bus 2. Power to DC bus 2 is now from TR1 and TR3 (via the TR3 disconnect relay).

PT. METRO BATAVIA Directorate of Operational

Slide 55 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 56 of 90

Non-Normal Indications
DC Metering Panel

Indications of an inoperative TR3 are:

0 (zero) DC amps.

0 (zero) DC volts.

PT. METRO BATAVIA Directorate of Operational

Slide 57 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 58 of 90

Normal Indications
AC Metering Panel
Normal indications with STBY PWR selected are:

400 CPS, +/-10 CPS

115 volts, +/-5 volts

PT. METRO BATAVIA Directorate of Operational

Slide 59 of 90

Normal Indications
AC Metering Panel
Normal indications with GRD PWR selected are:

400 CPS, +/-10 CPS

115 volts, +/-5 volts

PT. METRO BATAVIA Directorate of Operational

Slide 60 of 90

Normal Indications
AC Metering Panel
Normal indications with GEN 1 selected are:

400 CPS, +/-10 CPS

115 volts, +/-5 volts

PT. METRO BATAVIA Directorate of Operational

Slide 61 of 90

Normal Indications
AC Metering Panel
Normal indications with APU GEN selected are:

400 CPS, +/-10 CPS

115 volts, +/-5 volts

PT. METRO BATAVIA Directorate of Operational

Slide 62 of 90

Normal Indications
AC Metering Panel
Normal indications with GEN 2 selected are:

400 CPS, +/-10 CPS

115 volts, +/-5 volts

PT. METRO BATAVIA Directorate of Operational

Slide 63 of 90

Normal Indications
AC Metering Panel
Normal indications with INV selected are:

400 CPS, +/-10 CPS

115 volts, +/-5 volts

PT. METRO BATAVIA Directorate of Operational

Slide 64 of 90

Constant Speed Drive (CSD) Panel


Low oil pressure < 120 psi Light Illumination High oil temperature 157 degree celcius Light Illumination

PT. METRO BATAVIA Directorate of Operational

Slide 65 of 90

Constant Speed Drive (CSD) Panel


LOW OIL PRESSURE Light: Illuminated Generator drive oil pressure is below minimum operating limits. < 120 PSI

PT. METRO BATAVIA Directorate of Operational

Slide 66 of 90

Constant Speed Drive (CSD) Panel


HIGH OIL TEMP Light: Illuminated Generator drive oil temperature exceeds operating limits. = 157 Degree Celcius

PT. METRO BATAVIA Directorate of Operational

Slide 67 of 90

Constant Speed Drive (CSD) Panel


DISCONNECT Switches: (guarded and safetied) Disconnects generator drive. Generator drive can not be reconnected inflight.

PT. METRO BATAVIA Directorate of Operational

Slide 68 of 90

Constant Speed Drive (CSD) Panel


DRIVE TEMP Switch: Selects RISE or IN temperature to be displayed on the GEN DRIVE OIL TEMP indicator.

PT. METRO BATAVIA Directorate of Operational

Slide 69 of 90

Constant Speed Drive (CSD) Panel


GEN DRIVE OIL TEMP Indicators: Displays the temperature of the oil used in the generator drive.

IN Scale (inner) Displays the temperature of the oil entering the generator drive.
RISE Scale (outer) Displays the temperature rise within the generator drive.

PT. METRO BATAVIA Directorate of Operational

Slide 70 of 90

Generator Drive and CSD Oil Cooler


Higher than normal temperature rise indicates excessive generator load or poor condition of the generator drive. Lack of adequate cooling by the oil cooler will generally cause the temperature rise to decrease.

FAN AIR

See picture of engine driven generator and CSD


GEN GEN 2 DRIVE

See picture of CSD oil cooler

PT. METRO BATAVIA Directorate of Operational

Slide 71 of 90

Standby Power
STANDBY POWER OFF Light: Illuminated AC standby bus is not powered.

PT. METRO BATAVIA Directorate of Operational

Slide 72 of 90

Standby Power
STANDBY POWER Switch: Three-position AUTO (guarded position), OFF and BAT.

PT. METRO BATAVIA Directorate of Operational

Slide 73 of 90

Standby Power
STANDBY POWER Switch:
AUTO (guarded position) In flight or on the ground, with normal power conditions: AC standby bus powered by transfer bus 1. DC standby bus powered by DC bus 1. In flight and loss off all AC power: AC standby bus powered by battery bus via static inverter. DC standby bus powered by battery bus. Fully charged battery will provide 30 min. of standby power. On the ground and loss off all AC power: No automatic transfer of power. AC and DC standby busses are not powered.

PT. METRO BATAVIA Directorate of Operational

Slide 74 of 90

Standby Power
STANDBY POWER Switch: OFF STANDBY PWR OFF light illuminates. AC standby bus, DC standby bus and static inverter are not powered.

PT. METRO BATAVIA Directorate of Operational

Slide 75 of 90

Standby Power
STANDBY POWER Switch: BAT AC standby bus is powered by battery bus via the static inverter. DC standby bus is powered by battery bus. The battery bus is powered by hot battery bus, regardless of the battery (BAT) switch position.

PT. METRO BATAVIA Directorate of Operational

Slide 76 of 90

Bus Switching Panel

PT. METRO BATAVIA Directorate of Operational

Slide 77 of 90

Bus Switching Panel


GRD POWER AVAILABLE Light: Illuminated Active ground power cord is connected to the aircraft. Does not indicate the quality of the ground power source. To determine quality, select GRD PWR on the AC metering panel. Light remains illuminated as long as an active ground power cord is connected to the aircraft, even if ground power is not being utilized as a power source.

PT. METRO BATAVIA Directorate of Operational

Slide 78 of 90

Bus Switching Panel


GRD PWR Switch: (spring-loaded to center) OFF Disconnects ground power from both generator busses.

ON If momentarily positioned to ON when ground power is available: removes previously connected power from the generator busses. connects ground power to generator busses, if ground power quality is correct. switches the ground service bus to generator bus 1. deactivates the ground service switch.
PT. METRO BATAVIA Directorate of Operational

Slide 79 of 90

Bus Switching Panel


AC AMPS (AC Ammeter): Indicates respective engine driven generator load in amps.

PT. METRO BATAVIA Directorate of Operational

Slide 80 of 90

Bus Switching Panel


BUS TRANSFER Switch:
AUTO (guarded position) Upon failure of one generator bus, respective transfer bus seeks power from active (opposite) generator bus. OFF Prevents transfer busses from seeking opposite generator bus. Prevents battery charger from seeking alternate power source (main bus 2). Opens TR3 disconnect relay. NOTE: The important item to remember is that whenever the BUS TRANSFER switch is positioned to OFF, the electrical system is now split. The left and right side of the electrical system are now independent. However, this will have not prevent the AC and DC standby busses from seeking their alternate power source (battery bus).

PT. METRO BATAVIA Directorate of Operational

Slide 81 of 90

Bus Switching Panel


TRANSFER BUS OFF Lights: Illuminated Respective transfer bus is inactive.

PT. METRO BATAVIA Directorate of Operational

Slide 82 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 83 of 90

Bus Switching Panel


BUS OFF Lights: Illuminated Respective generator bus is inactive.

PT. METRO BATAVIA Directorate of Operational

Slide 84 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 85 of 90

Bus Switching Panel


GEN OFF BUS Lights: Illuminated Respective engine driven generator is not supplying power to the related generator bus.

PT. METRO BATAVIA Directorate of Operational

Slide 86 of 90

EXTERNAL AC RECEPTACLE EXTERNAL AC BUS F F A ENGINE DRIVEN GENERATOR 1 V V


BUS PROTECTION PANEL

737-300/400 Electrical Schematic


F A V

F A

APU GEN

ENGINE DRIVEN GENERATOR 2

GENERATOR BUS 1

GENERATOR BUS 2

1 2
GROUND SERVICE SWITCH TRANSFER BUS RELAY 1

1 2
TRANSFER BUS RELAY 2

GROUND SERVICE BUS

MAIN BUS 1

TRANSFER BUS 1

TRANSFER BUS 2

MAIN BUS 2

T
R1

T
R2

T
R3 V A
LEGEND
AC POWER

DC BUS 1

1 2 1 2

TR3 DISCONNECT RELAY

DC BUS 2

1
DC STANDBY BUS

DC POWER

AC STANDBY BUS

2
V F
STATIC INVERTER

BATTERYBUS V

1
V

1
PRIMARY POWER SOURCE

V
BATTERY CHARGER

HOT BATTERYBUS A
BATTERY

2
SECONDARY POWER SOURCE

APU START BATTERY CHARGER CUTOUT RELAY

SWITCHED HOT BATTERY BUS

EXTERNAL DC RECEPTACLE

PT. METRO BATAVIA Directorate of Operational

Slide 87 of 90

Bus Switching Panel


APU GEN OFF BUS Light: Illuminated APU generator is at 95% of its governed speed and is currently not supplying power to generator bus 1 or generator bus 2.

PT. METRO BATAVIA Directorate of Operational

Slide 88 of 90

Bus Switching Panel


APU GEN Switches: (spring-loaded to center) ON Connects APU generator to respective generator bus if quality of APU generator power is correct. OFF Disconnects APU generator from the respective generator bus.

PT. METRO BATAVIA Directorate of Operational

Slide 89 of 90

Bus Switching Panel


GEN Switches (1 and 2): (spring-loaded to center) ON Connects engine driven generator to respective generator bus if quality of engine driven generator power is correct. OFF Disconnects engine driven generator from the respective generator bus.

PT. METRO BATAVIA Directorate of Operational

Slide 90 of 90