Professional Documents
Culture Documents
5/6--10
50 Hz
Applications
--------Drinking and service water supply Irrigation and spray irrigation Lowering and maintaining ground water levels Pressure boosting Fountains Mining, offshore, tank farms Building services systems VDS sprinkler systems up to 840 m3/h (233 l/s) up to 480 m up to +50 C 2900 rpm up to 10,000 V
Operating Data
Capacity Head Temperature of fluid handled Speed Supply voltage Q H t n U
Design
Single-- or multistage centrifugal pumps in pump shroud or in ring--section design. Radial or mixed flow hydraulic systems; reduced impeller diameters also available in some cases. The stage casings of radial pumps are connected by metal straps, those of mixed flow pumps by stud bolts. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with check valve or connection branch on option. Available with threaded or flanged end on option. Particularly suitable for vertical installation in narrow deep wells.
200 B --
80 / 5 b
Available automation products: Hyamaster (UPA 200 -- UPA 350) hyatronic (UPA 200 -- UPA 350) switch gear (S 100D -- UPA 350)
Complete Range
The complete submersible borehole pump range comprises pump models for flow rates up to Q = 2500 m3/h (695 l/s) and heads up to H = 1500 m. The submersible motor range covers sizes for power ratings up to P = 3500 kW and voltages up to U = 10,000 V for 50 and 60 Hz. In addition, a special range is available which features submersible motors with a higher number of poles.
Certification
Quality management certified to ISO 9001
50 Hz
Contents
The Submersible Borehole Pump Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation with Soft Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operation with Frequency Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Typical Installation Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Submersible Borehole Pump Selection for Deep Wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Request for Quotation (Form) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Head Losses in the Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Pump Sets 4 inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 + 23 Pump Sets 6 inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Pump Sets 8 inches / 10 inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Pump Sets 12 inches / 14 inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Pump Sets 16 inches and above . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 + 95 Typical Tenders: 4 to 14 inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Submersible Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 Flow Velocity v Past the Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
50 Hz What can you expect from the Submersible Borehole Pumps Booklet?
The information provided can help you make a -- quick -- first rough selection -- on your own to find a suitable KSB submersible borehole pump for your application. We have kept the volume of the catalogue down to what we think is the absolute minimum. For the 4 to 14 inch range, you will find the following information on the pump selected: -- pump series, size and number of stages, -- motor series, size, power, amperage, and allowable temperature, -- starting method, supply voltage and type of installation, -- material variants and -- major dimensions and weights. You may also complete, to the extent possible, the request for quotation on page 9. You will then receive as soon as possible a detailed quotation and, if required, additional literature on KSB submersible borehole pumps from the nearest KSB sales branch.
General
Information on fields of application, available models, type of installation, direction of rotation, coating, connection to power supply and speed control is provided in the detailed sections for the relevant type series. The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
Pump Efficiency
The characteristic curves for UPA 200/200B and larger pumps show pump efficiency for the maximum and optimum (reduced) impeller diameter (for ex. c). The efficiency of pumps with a low number of stages or considerably reduced impeller diameter (for ex. d, e) is lower than the value shown; it is given in the individual characteristic curves specifically prepared for the quotation.
Application Temperatures
The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = +30 oC. An indispensable requirement for this is a flow velocity of v = 0.2 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = +50 oC and for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.). The details below provide data of adequate accuracy for the allowable temperature as a function of the type of installation, motor size and flow velocity v past the motor: Vertical installation: -- DN 100: tallow = tmax1) irrespective of flow past the motor. -- UMA 150D/200D: v = 0 m/s . . . . . . tallow tmax1) -- 5 oC, v 0.2 m/s . . . . . tallow = tmax1), v 0.5 m/s . . . . . tallow tmax1) + 5 oC. -- UMA 250D: v = 0 m/s . . . . . . Please consult manufacturer, v 0.2 m/s . . . . . tallow = tmax1), v 0.5 m/s . . . . . tallow tmax1), + 5 oC.
1)
Benefits at a Glance
+ + + + + + + + + Full range of products High-tech equipment Optimum material selection Maximum efficiency Functional reliability Long service life No maintenance Clean technology Customer focus
Horizontal installation: The principle is the same as for vertical installation. Exception: Pumps with UMA 250D motors. These units must always be equipped with a flow inducer sleeve. The flow inducer sleeve is not required, if the given pump is equipped with a motor having a 10 % higher power rating. For all pump sets: For a flow velocity of v 0.5 m/s and horizontal installation, check back with the manufacturer.
UPV 150S
(6 inch) on request
(8 inch) on request
" S 100D
(4 inch) p. 11 -- 22
50 Hz
Note
Conspicuous noise or vibrations during run-up could well be an indication of incorrect settings on the soft starter. This might be due to exceeded ramp--up periods, incorrect operating mode (setting), activated special functions, etc.
During operation the soft starter must be bridged (bypass). This helps to avoid losses at the machine and motor to secure proper permanent operation.
Run--up
Operation
Run--down
4s
Time [s]
4s
Maximum Allowable Acceleration Time (Start Ramp) and Deceleration Time (Stop Ramp)
The plain bearings of the submersible motor do not tolerate operation below the minimum frequency fmin (operation in mixed lubrication range). For this reason, the acceleration period from standstill to minimum frequency fmin should not exceed 2s. The same applies to the deceleration period.
For motor sizes DN 100, the limit values for J1 insulation apply. Note: Compliance with these limits can usually be assured by means of a sine filter or du/dt filter.
Minimum Frequency
Minimum frequency fmin (Hz) Motor size Vertical installation Horizontal installation
DN 100 UMA 150D UMA 200D UMA 250D UMA 300D /2 UMA 300D /4
30 20
30 30
30
35
CAUTION:
The construction of the well head must meet the relevant regulations of the competent authorities! The unit must never be installed with its suction strainer exactly at the level of the well screen / filter!
Before installing the unit in narrow deep wells we recommend to check narrow boreholes for dimensional accuracy over their entire length, e.g. by inserting a pipe of the length and biggest outside diameter of the pump unit. Sharp bends or bottlenecks can make installation difficult or even impossible. The unit is supported on the well head by supporting clamps (low-weight units and low submergence) or a supporting flange. The construction of the well head must meet the relevant regulations of the competent authority.
5 4 8
Fig. 2
b)
Hh Ht 3
B B
He
1 2 3 4 5 6 7 8 9 D TB TF He Hh Ht
Submersible borehole pump Riser pipe 1 Cable tie Supporting flange / Well head Pressure gauge Shut-off valve Power supply cable 9 Control box Well screen / filter = = = = = = Inside well diameter D Well depth Well screen / filter depth Installation depth Static water level Dynamic water level (Pumping water level)
Vertical installation (in deep well, pump sump, etc.)
TF TB
CAUTION: The instructions given in a) Vertical installation shall also apply by analogy to horizontal installation, when the pump unit is fitted on mounts (pedestals / supporting frame) supplied by us. If the pump and motor are supplied ready mounted on a supporting frame, on-site alignment of pump and motor will not be necessary. If this is not the case, the relevant installation / assembly drawing must be ordered, giving the following details: -- installation height (floor clearance), -- spacing of supports, -- submergence X The ground / foundation must be level and of sufficient load-bearing capacity to accept the weight of the unit with supports. Air intake from an inlet arranged above the water level is not permitted.
Fig. 1
The suspension arrangement of the pump unit must be designed and dimensioned so that all static and dynamic forces can be absorbed and that the riser pipe cannot slip downwards. The supporting clamps or flanges must be fastened at the well head so that they cannot shift of lift off the well head. The unit must never be installed with its suction strainer exactly at the level of the well screen / filter! Excessive flow in the area of the well screen / filter entails the risk of large amounts of entrained sand clogging the well screen / filter and causing excessive wear in the pump. Pump units installed in a pump sump must generally be equipped with a cooling or suction shroud (fig. 2).
Fig. 3
1 2 3 4 5
Submersible borehole pump Water storage tanks (UMA 300D and 14D motors only) Pedestal Expansion joint Check valve (only if pump unit does not have its own check valve) 6 Dismantling joint 7 Shut-off valve 8 Intake
1.
HP = HA + Ht + Hv + HS [m] where ... HA = Required pressure at well head Ht = Lowest water level (dynamic water level) Hv = Head losses in the check valve (see characteristic curves for different stage numbers for UPA 150C and above). HS = Head losses in riser pipe up to well head (see page 10). He = Installation depth
2.
Example
Given ... QA = 120 m3/h, HA = 95 m, tA = + 15 C, 50 Hz, 400 V and d.o.l. starting, well diameter D = 250 mm (10 inches). Found ... 1. step: pump type UPA 200B/250C (for QA taken from selection chart on page 4) 2. step: pump size UPA 200B - 130 (for QA taken from selection chart on page 50) 3. step: pump set UPA 200B-130/6b + UMA 200D 45/21 (for Hp = HA + Ht + HV + HS = 95 + 4 + 0.75 + 0.26 = 100 m with HV taken from characteristic curves for different stage numbers on page 61). Pump efficiency: P = 80.5 % (without check valve)
3300:54/3
Figure: Deep well with submersible borehole pump and overhead tank or closed tank at a pressure above atmospheric pressure of p. 8
We should like to test the efficiency and quality of your computer-aided quotation process. Please let us have a quotation based on the following data. (Fill in the required data and / or underline the relevant information, as far as available.)
1. Water quality
Temperature . . . . . . . . . . . . . . . . . . . . . C
8
Discharge head required at the end of the piping: H = . . . . . . . . . . . . . m ( . . . . . . . . bar) Cut-out pressure in the pressure vessel: p = . . . . . . . . . . . . bar
2. Type of system
7 6
c) Piping outside well head housing: Overall length . . . . . . . . . . . . . . . . . . . . m Nominal diameter . . . . . . . . . . . . . . . mm Number of bends, valves and fittings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pcs Inside diameter reduced by incrustation to: D = . . . . . . . . . . . . . . . . . . . . . . . . mm
Well / Mine shaft / Tank Free discharge above ground Discharge into an overhead tank Discharge into a pressure vessel
3. Deep well
5
Well depth (distance from ground level to well base): TB = . . . . . . . . . . . . . . . . . . . . . . . . . . . . m Inside diameter at submersible pump installation depth: D = . . . . . . . . . . . . . . mm ( . . . . inches)
6. Installation depth
Ground level to check valve / to connection branch: He = . . . . . . . . . . . . m Caution: Do not install the submersible borehole pump at the level of the well screen / filter!
7. Power supply
Single- / three-phase alternating current. Mains voltage at well: U= ............................. V Frequency f = . . . . . . . . . . . . . . . . . . Hz
4. Capacity
3 2
Q = . . . . . . . . . . . . . m3/h ( . . . . . . . l/s)
5. Total head
(including all friction losses) H= ............................ m If H is not known, please provide the following data: F
3300:54/3
a) Water level in well, measured from ground level: -- Static water level: Hh = . . . . . . . . . . m -- Dynamic water level: Ht = . . . . . . . . m (at capacity Q = . . . . . . . . . . . . . . m3/h) b) Head above ground: Geodetic altitude up to the highest point of the pipeline or up to the highest water level in the overhead tank: Hd = . . . . . . . . . . . . . . . . . . . . . . . . . . . m
8. Control box
Manual start-up / remote control / automatic start-up by way of float switch, pressure switch or dry running protection equipment. Other types of switchgear: . . . . . . . . . . . ...................................
1 2 3 4 5 6 7 8
Well screen / filter Well casing Submersible borehole pump Riser Well head housing Well head Power supply cable Overhead tank
9. Starting method
D.o.l. (without / with autotransformer or soft starter) or star-delta starting. 9
HV ft/100 ft HV m/100 m
3300:103/3-2
The friction losses given in the above chart roughly apply to new cast iron pipes. For new rolled steel or plastic pipes, multiply the values by approx. 0.8. For old, slightly rusty cast iron pipes, multiply by approx. 1.25. In pipes with incrustations, friction losses may rise to 1.7 times the value given in the chart for the 10
diameter reduced by incrustations. For pipes subject to considerable incrustation, the friction losses can only be determined experimentally. Example: Q = 140 m3/h, new DN 150 cast iron pipe. HV = 3.25 m per 100 m of pipe, v = 2.2 m/sec.
50 Hz Applications
--------Domestic and general water supply Irrigation and spray irrigation Lowering groundwater levels Fountains Pressure boosting Air-conditioning systems Fire protection Cooling water cycles
Operating Data
Capacity Head Temperature of fluid handled Power
Designation
S 100 D -- 4 / 6 Type series Well diameter (mm) Status Capacity (m3/h) Number of stages Available automation products: Automatic control unit
Product Features
--------Pumps sizes D1 and D2 with anti-blockage feature Rust-proof Suitable for installation in narrow deep wells High efficiency Hermetically sealed motor Motor designed for maximum pump output Low noise level For vertical, angled or horizontal installation
Recommended Accessories
UPA Control: Control box for motor and dry running protection by immersion electrodes. Automatic control unit: in conjunction with the Controlmatic E or Cervomatic EDP control and monitoring units, which protect the pump against dry running, if the water level falls, S 100D can be used for automatic water supply
Certification
Quality management certified to ISO 9001
11
50 Hz
Selection Chart (Ranges on Offer)
Note: Up to a motor rating of PN = 2.2 kW, all pump sizes can be supplied with either single-phase a.c. or three-phase current motors.
12
50 Hz Materials
Component Pump ... Outer pump casing/ Suction casing / Valve housing Stage casing Stage casing (diffuser) / Impeller Shaft Bearing bush Screws, bolts and nuts Motor ... Shaft Bearing carrier Stator case
S 100D
Drive
C1
CrNi steel (1.4301) Type . . . . . . . . . . . . . . . . . . . . canned motor in squirrelcage design, 2 poles Connection . . . . . . . . . . . . . . NEMA standard Type of enclosure . . . . . . . . IP 68 Frequency . . . . . . . . . . . . . . 50 Hz Type of current . . . . . . . . . . . single-phase a.c. (1 ) or three-phase (3 ) Rated voltage U . . . . . . . . . . 220 ... 230 V (1~) and 380 ... 400 V (3~) Rated power PN . . . . . . . . . . . . up to 2.2 kW for 1~ and up to 5.5 kW for 3~ Voltage fluctuation . . . . . . . . up to 5 % acc. to VDE Frequency of starts . . . . . . . up to 20/h Min. delay before restarting . 3 min A starter for single-phase a.c. motors in PSC design (with integrated run capacitor and motor protection) is included in the scope of supply.
CrNi steel (1.4301) glass fibre reinforced Noryl (PPO GF20V) Cr-steel (1.4021) Nitril NBR 80 CrNiMo-steel (A4--70) CrNi steel (1.4305) CrNi steel (1.4301) CrNi steel (1.4301)
Bearings / Lubrication
Plain bearings, lubricated by the fluid pumped or by the motor fill liquid. Depending on the number of stages, an additional intermediate bearing is provided in the pump. The axial thrust is balanced by a thrust bearing in the motor. The hydraulic thrust is balanced by the pumps counter thrust bearing.
Installation
Vertical and, depending on the number of stages, also angled and horizontal installation.
Starting Mode
Only direct on line.
Temperatures
The S 100D submersible borehole pump is designed for use in water with temperatures of up to t = + 30 oC.
13
S 100D
High-duty impellers D Made of glass fibre-reinforced Noryl, highly abrasion- and corrosion-resistant. D With integrated keys for easy assembly.
Stainless steel cable guard D Easy assembly and dismantling. D Protects the power supply cable against damage during installation and dismantling.
Highly corrosion-resistant
D Suction casing, check valve housing and outer casing made of stainless steel D Hydraulic system made of glass fibre reinforced Noryl Stainless steel stage casing without return vanes D High pressure resistance. D Easy assembly and dismantling.
14
50 Hz S 100D - 1 ...
for well diameters of 100 mm (4 inch) Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . . . . . . . . up to + 30 oC -- Current / Operating voltage . . . . . . . . . . . . . . . . . . 1~/230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . or 3~/400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . direct
Rated power (motor) Current intensity for ... 1~ 230 V IN 1) A 3~ 400 V IN A Installation 2) Operation with control unit 3)
S 100D
PN kW
1/ 7 1/ 9 1 / 12 1 / 14 1 / 16 1 / 20 1 / 25 1 / 30 1 / 35 1 / 40 1 / 50
1) 2) 3)
0.37 0.37 0.55 0.55 0.55 0.75 1.10 1.10 1.50 1.50 2.20
3.4 3.4 3.4 4.3 4.3 4.3 5.7 5.7 8.6 8.6 10.6
1.3 1.3 1.3 1.7 1.7 1.7 2.2 2.2 3.2 3.2 4.0
x x x x x 3) x 3) x 3) x 3) x 3) x 3) x 3)4)
Capacity
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
Capacitor run motors (PSC motors) with starter. v = vertical and h = inclined / horizontal. Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded. 4) 3~ only
G 11/4
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21. 15
50 Hz S 100D - 2 ...
for well diameters of 100 mm (4 inch) Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . . . . . . . . up to + 30 oC -- Current / Operation voltage . . . . . . . . . . . . . . . . . . 1~/230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . or. 3~/400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . direct
Rated p power ( t ) (motor) Pump unit S 100D PN kW Current intensity for ... 1~ 3~ 230 V 400 V IN 1) A IN A Installation
2)
S 100D
2/ 7 2 / 11 2 / 15 2 / 18 2 / 20 2 / 22 2 / 27 2 / 30 2 / 33 2 / 38 2 / 44 2 / 50
1) 2) 3)
0.37 0.55 0.75 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 3.0
3.4 4.3 5.6 8.6 8.6 8.6 10.6 10.6 15.5 15.5 15.5 --
1.3 1.7 2.2 3.2 3.2 3.2 4.0 4.0 5.9 5.9 5.9 7.8
x x x x 3) x 3) x 3) x 3) x 3) x 3) x 3) x 3) x 3)4)
Capacity
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
Capacitor run motors (PSC motors) with starter. v = vertical and h = inclined / horizontal. Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded. 4) 3~ only
11.3 13.0 14.8 17.7 17.8 18.0 19.5 19.9 23.6 24.1 24.6 -----
G 11/4
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21. 16
50 Hz S 100D - 4 ...
for well diameters of 100 mm (4 inch) Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . . . . . . . . up to + 30 oC -- Current / Operating voltage . . . . . . . . . . . . . . . . . . 1~/230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . or 3~/400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . direct
Rated p power ( t ) (motor) Pump unit S 100D PN kW Current intensity for ... 1~ 3~ 230 V 400 V IN A
1)
S 100D
Installation
2)
IN A
4/ 3 4/ 6 4/ 8 4 / 11 4 / 16 4 / 21 4 / 24 4 / 33 4 / 40
1) 2) 3)
Capacitor run motors (PSC motors) with starter. v = vertical and h = inclined / horizontal. Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded. 4) 3~ only
Capacity
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
G 11/4
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21. 17
50 Hz S 100D - 7 ...
for well diameters of 100 mm (4 inch) Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . . . . . . . . up to + 30 oC -- Current / Operating voltage . . . . . . . . . . . . . . . . . . 1~/230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . or 3~/400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . direct
Rated p power ( t ) (motor) Pump unit S 100D PN kW Current intensity for ... 1~ 3~ 230 V 400 V IN 1) A IN A Installation
2)
S 100D
7/ 4 7/ 6 7/ 8 7 / 11 7 / 13 7 / 18 7 / 23 7 / 28 7 / 33
1) 2) 3)
Capacitor run motors (PSC motors) with starter. v = vertical and h = inclined / horizontal. Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded. 4) 3~ only
Capacity
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
G 11/4
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21. 18
50 Hz S 100D - 12 ...
for well diameters for 100 mm (4 inch) Pumps with submersible motors for ... -- Temperature of fluid handled . . . . . . . . . . . . up to + 30 oC -- Current / Operation voltage . . . . . . . . . . . . . . . . . . 1~/230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . or 3~/400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . direct
Rated p power ( t ) (motor) Pump unit S 100D PN kW Current intensity for ... 1~ 3~ 230 V 400 V IN 1) A IN A Installation 2) Operation with control t l unit
3)
S 100D
12 / 4 12 / 6 12 / 10 12 / 13 12 / 17 12 / 21 12 / 25
1) 2) 3)
x x x x 4) x 3)4) -----------
Capacitor run motors (PSC motors) with starter. v = vertical and h = inclined / horizontal. Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded. 4) 3~ only
G 2
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21. 19
S 100D
3~/ 400 V
Installation 1) Dimension (dia. x length) and motor type (kW) v+h 115 (130) x 400 v for o motor oto up to 0.75 0 5 kW (1~) ( ) or up to 0.75 kW (3~) v+h Weight 1.5 kg v+h v+h v 115 (130) x 500 for motor up to 1.5 kW (1~) v+h or up to 1.5 kW (3~) v Weight 1 1.7 7 kg v+h v+h v+h v 115 (130) x 625 v+h for motor up to 2.2 kW (1~) v or up to 3.0 kW (3~) v+h Weight 2.0 kg v+h v v 115 (130) x 800 for motor up to 5.5 kW (3~) v Weight 2.5 kg v
90 065 491
90 065 492
90 065 493
20
50 Hz Accessories: UPA Control for Dry Running Protection (using 3 immersion electrodes)
S 100D-1/..
Relais Tlmcanique (A) 2.5 to 4.0 4.0 to 6.0 5.5 to 8.0 7.0 to 10 9.0 to 13
S 100D
1~
Electrode (Qty.) (3) (3) (3) (3) (3) 7 9 12 X X X X X 14 16 20 25 30 35 40
S 100D-1/...
Relais Tlmcanique (A) 1.0 to 1.6 1.6 to 2.5 2.5 to 4.0
3~
Electrode (Qty.) (3) (3) (3) 7 9 12 X X X 14 to 30 35 40 50
50
Ident No. 40 980 891 40 980 893 40 990 895 40 980 897 40 980 899
S 100D-2/..
Relais Tlmcanique (A) 2.5 to 4.0 4.0 to 6.0 5.5 to 8.0 7.0 to 10 9.0 to 13 12 to 18
1~
Electrode (Qty.) (3) (3) (3) (3) (3) (3) 18 20 22 27 30 33 38 44
S 100D-2/...
Relais Tmcanique (A) 1.0 to 1.6 1.6 to 2.5 2.5 to 4.0 5.5 to 8.0
3~
Electrode (Qty.) (3) (3) (3) (3) 11 15 18 to 30 33 44 50
7 X
11
15
7 X
X X X X X
40 980 893 40 990 895 40 980 897 40 980 899 40 984 811
X X X
S 100D-4/..
Relais Tlmcanique (A) 2.5 to 4.0 4.0 to 6.0 5.5 to 8.0 7.0 to 10 9.0 to 13 12 to 18
1~
Electrode (Qty.) (3) (3) (3) (3) (3) (3) 21 24
S 100D-4/...
Relais Tlmcanique (A) 1.0 to 1.6 1.6 to 2.5 2.5 to 4.0 5.5 to 8.0 7.0 to 10
3~
Electrode (Qty.) (3) (3) (3) (3) (3) 6 8 11 16 21 24 33 40
3 X
11
16
3 X
X X X X X
40 980 893 40 990 895 40 980 897 40 980 899 40 984 811
X X X X
S 100D-7/..
Relais Tlmcanique (A) 5.5 to 8.0 7.0 to 10 9.0 to 13 12 to 18
1~
Electrode (Qty.) (3) (3) (3) (3) 11 13
S 100D-7/...
Relais Tlmcanique (A) 1.6 to 2.5 2.5 to 4.0 5.5 to 8.0 7.0 to 10 12 to 18
3~
Electrode (Qty.) (3) (3) (3) (3) (3) 6 8 11 13 18 28 33
4 X
4 X
23
X X X
X X X X
S 100D-12/..
Relais Tlmcanique (A) 7.0 to 10 9.0 to 13 12 to 18
1~
Electrode (Qty.) (3) (3) (3)
S 100D-12/...
Relais Tlmcanique (A) 2.5 to 4.0 5.5 to 8.0 7.0 to 10 12 to 18
3~
Electrode (Qty.) (3) (3) (3) (3) 4 6 X X X X 13 17 21 25
4 X
10
10
Ident No. 40 980 891 40 980 895 40 980 897 40 984 811
X X
21
50 Hz
S 100D
22
50 Hz Applications
-- Domestic and general water supply -- Irrigation and spray irrigation -- Lowering ground water levels -- Fountains -- Pressure boosting -- Air-conditioning systems -- Fire protection -- Cooling water cycles Maximum permissible amount of suspended sand: 50 g/m3
UPA 100C Submersible Borehole Pumps for Well Diameters of 100 mm (4 inches)
Operating Data
Capacity Head Temperature of fluid handled Motor ratings Q H t PN up to 15 m3/h (250 l/min) up to 400 m 30 C up to 7.5 kW
Design
Multistage centrifugal pump with components made of stainless steel and additional bearing for each stage. The stage casings are connected by means of tie bolts on radial pumps, and by means of studs on mixed--flow pumps. Submersible canned motor: Franklin Electric pre-filled motors, corrosion free, NEMA shaft end, 50 Hz -- Single-phase and three-phase motor type Super Stainless -- With separate lead -- Direct starting, max starts per hour: 20 -- Type of enclosure: IP 68 -- Insulation: Class B
Designation (Example)
UPA 100 C 4 -- 6 Type series Minimum well diameter (mm) Design status Capacity Qopt (m3/h) Number of stages
Certification
Quality management certified to ISO 9001
Product Features
----------Very sturdy design All components made of stainless steel Suitable for installation in narrow deep wells High efficiency Totally enclosed motor Motor designed for maximum pump output Low noise level For vertical or horizontal installation Check valve protected against blocking Pre-filled motor; no risk of contamination of the pumped water
23
UPA 100C 2
UPA 100C 12
UPA 100C 4
UPA 100C 7
UPA 100C 12
3.6
12
30
60
Q l/min
120
180
300
24
50 Hz Materials
Component Pump ... Diffuser Upper diffuser Lower diffuser Impeller Pump shaft with Nema coupling Suction casing Suction filter Discharge casing Spacer sleeve Hook Seal ring Upper bearing bush Intermediate bearing bush Valve face Motor ... Shaft Bearing housing Stator case
UPA 100C
Drive
C1
Type Connection Enclosure Frequency f Type of current Rated voltage U submersible canned motor NEMA standard IP 68 50 Hz single-phase and three-phase 1~ 230 V, 3~ 400 V, up to 7.5 kW up to +/-- 10 % up to 20 / h
NBR + AISI 316 NBR + AISI 316 NBR NBR + AISI 316 stainless steel AISI 304 SS stainless steel AISI 304 SS stainless steel AISI 304 SS
Rated power PN Voltage fluctuations Frequency of starts Min. delay before restarting 3 min A start box with integrated phase-shifting capacitor and thermal protection is included in the scope of supply of single-phase pump sets in PSC design.
Starting Mode
Direct on line.
Temperatures
The UPA 100 C submersible borehole pump is designed for use in water with temperatures of up to +30 C.
Discharge Nozzle
UPA 100C 2 -- 3 -- 4: UPA 100C 7 -- 12 Rp 11/2 Rp 2
Installation
Vertical or horizontal installation without restriction. In order to guarantee the dissipation of the motor heat it will be necessary to install a device guiding the flow along the motor (cooling jacket, flow inducer sleeve, etc.) in horizontal installation.
25
50 Hz Design Features
UPA 100C
Optimised operating costs: Check valve, built into the discharge chamber, designed for low loss of head.
Resistance to corrosion and abrasion, i.e. the same inherent qualities of stainless steel.
Oversized intermediate bearings located at each pump stage to align the shaft, specially designed to optimize lubrication.
Reliable in service: Very strong construction: minimum thickness of stainless sheet steel of 1 mm, 6 spot welding on each vane, special top bearing for every pump.
Coupling and flange suitable for motors with pump mounting dimensions in accordance with NEMA standards.
Friendly service: Great ease of dismantling and assembly. Easy-to-replace wear-rings and bearings.
26
UPA 100C
UPA 100C 2 - ...
(Tolerances to ISO 2548 Class C, Annex B)
-- 66
-- 60
-- 54
Rp 11/2
-- 47
-- 40 -- 35
-- 30
-- 25 -- 21
-- 17 -- 13
-- 8 -- 6
Rated a ed power (Motor) Pump set UPA 100C 2 -.. 6 8 13 17 21 25 30 35 40 47 PN kW 0.37 0.37 0.55 0.75 1.1 1.1 1.5 1.5 2.2 2.2
Rated current for 1~ 220 V IN 1) A 3.2 3.6 5.7 6.9 8.0 8.9 9.5 11.1 12.1 14.5 3~ 400 V IN A 0.9 1.1 1.5 2.0 2.8 3.0 3.3 3.8 5.1 5.4 Operating range: 0.5 -- 2.5 m3/h Qmin = 0.5 m3/h Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
54 2.2 3 15.9 5.6 60 3.0 4 -6.8 66 3.0 4 -7.2 72 3.0 4 -7.5 1) Capacitor run motors (PSC motors) with starter.
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. Accessories: UPA Control for dry running protection see page 32.
27
UPA 100C
D1
-- 62
-- 57
-- 51
Rp 11/2
-- 44
-- 36
-- 30
-- 25 -- 22
-- 18 -- 15 -- 12 -- 9 -- 6
Rated a ed power (Motor) Pump set UPA 100C 3 -.. 6 9 12 15 18 22 25 30 36 44 PN kW 0.37 0.55 0.75 1.1 1.1 1.5 1.5 2.2 2.2 3.0
Rated a ed power (Motor) PN hp 0.5 0.75 1.0 1.5 1.5 2.0 2.0 3.0 3.0 4.00
Rated current for 1~ 220 V IN 1) A 3.6 5.7 6.9 8.7 8.9 9.8 11.1 12.5 15.9 -3~ 400 V IN A 1.1 1.5 2.0 2.9 3.0 3.6 3.8 5.2 5.6 7.0 Operating range: 1.0 -- 3.5 m3/h Qmin = 1.0 m3/h Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
51 3.0 4.0 -7.2 57 3.7 5.0 -8.8 62 3.7 5.0 -9.1 68 4.0 5.5 -10.00 1) Capacitor run motors (PSC motors) with starter.
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. Accessories: UPA Control for dry running protection see page 32.
28
UPA 100C
UPA 100C 4 - ...
(Tolerances to ISO 2548 Class C, Annex B)
-- 66
-- 60
-- 54
Rp 11/2
-- 50
-- 45
-- 39
-- 34
-- 29 -- 24
-- 19
-- 14
-- 9 -- 7 -- 4
50 3.7 5.0 -9.1 54 4.0 5.5 -10.0 60 5.5 7.5 -11.5 66 5.5 7.5 -12.5 72 5.5 7.5 -13.2 1) Capacitor run motors (PSC motors) with starter.
Operating range: 1.0 -- 5.0 m3/h Qmin = 1.0 m3/h Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. Accessories: UPA Control for dry running protection see page 32.
29
UPA 100C
UPA 100C 7 - ...
(Tolerances to ISO 2548 Class C, Annex B)
-- 59
-- 54
-- 49
-- 44
-- 39 -- 34 -- 32 -- 29 -- 26 -- 23
-- 19 -- 16 -- 13 -- 9 -- 6 -- 4 -- 3
54 7.5 10.0 -17.5 59 7.5 10.0 -18.3 64 7.5 10.0 -19.1 1) Capacitor run motors (PSC motors) with starter.
Operating range: 2.0 -- 8.0 m3/h Qmin = 2.0 m3/h Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation. 3~ / 400 V Ident. No. 90 065 327 90 065 328 90 065 329 90 065 330 90 065 331 90 065 332 90 065 333 -----B mm 223 242 271 299 327 356 356 423 423 545 545 583 698 698 698 774 774 774 C mm 500 542 620 720 844 946 1118 1182 1254 1448 1521 1607 1843 1964 2084 2280 2402 2522 Ident. No. 90 065 430 90 065 431 90 065 432 90 065 433 90 065 434 90 065 435 90 065 436 90 065 437 90 065 438 90 065 439 90 065 440 90 065 441 90 065 442 90 065 443 90 065 444 90 065 445 90 065 446 90 065 447 mA kg 10.2 11.5 13.5 15.8 18.5 21.0 22.0 25.9 27.0 33.0 34.0 37.9 45.0 46.8 48.6 53.9 55.7 59.5
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. Accessories: UPA Control for dry running protection see page 32.
30
UPA 100C
UPA 100C 12 - ...
(Tolerances to ISO 2548 Class C, Annex B)
-- 24
-- 20
-- 17
-- 14
-- 13 -- 10
-- 8
-- 5 -- 3
14 4.0 5.5 -10.0 17 5.5 7.5 -12.5 20 5.5 7.5 -13.2 24 7.5 10.0 -18.3 27 7.5 10.0 -19.1 1) Capacitor run motors (PSC motors) with starter.
Operating range: 4.0 -- 15.0 m3/h Qmin = 4.0 m3/h Qmax = End of characteristic curve The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. Accessories: UPA Control for dry running protection see page 32.
31
50 Hz UPA Control
Accessory: UPA Control for dry running protection (using 3 immersion electrodes)
Relay (A) 1.0 to 1.6 1.6 to 2.5 2.5 to 4.0 4.0 to 6.0 5.5 to 8.0 7.0 to 10 9.0 to 13 12 to 18 18 to 25 Ident. No. 40 980 887 40 980 889 40 980 891 40 980 893 40 980 895 40 980 897 40 980 899 40 984 811 90 052 649
UPA 100C
72 49, 54 17, 20
59, 64 24, 27
90 066 480
90 066 481
90 066 482
32
50 Hz Applications
Suitable for handling clean or slightly contaminated water in applications such as: -- domestic water supply -- general water supply -- irrigation and spray irrigation systems -- artificial lowering of the ground water level as well as -- heat transfer plants In addition, the pump sets are used in pressure boosting systems, air-conditioning systems, fountains, etc. Permissible sand content in the fluid handled: 50 g/m3.
UPA 150C Submersible Borehole Pumps for Well Diameters of 150 mm (6 inches)
Operating Data
Capacity . . . . . . . . . . . . . . . . . . Head . . . . . . . . . . . . . . . . . . . . . Temperature of fluid handled . Speed . . . . . . . . . . . . . . . . . . . . Q H t n up to 79 m3/h up to 570 m up to 50 C 2900 rpm
Design
Multistage centrifugal pump with components made of stainless steel and additional bearing for each stage. The stage casings are connected by means of tie bolts. Motor Canned or wet submersible squirrel-cage motor, 2 poles; NEMA shaft end; 50 Hz; type of enclosure: IP 68
Designation (Example)
UPA 150 C - 16 / 9 Type series Minimum well diameter (mm) Design status Capacity (m3/h) Number of stages
Certification
Quality management certified to ISO 9001
Product Features
-- Rust-proof -- Suitable for installation in narrow deep wells -- High efficiency -- Motor designed for maximum pump output -- Low noise level -- For vertical, angled or horizontal installation -- Check valve with anti-blockage valve disc
33
UPA 150C - 60
UPA 150C - 16
UPA 150C - 30
UPA 150C - 48
UPA 150C - 16
UPA 150C - 30
34
50 Hz Material Variants
Material C1 Pump Suction casing Stage casing Stage casing with hole Upper stage casing Suction strainer Flanged end piece Shaft Impeller Thrust bearing Counter thrust bearing O-ring Casing wear ring Impeller wear ring Bearing bush Disc Valve body Valve spring Valve plate Coupling Tiebolt Hexagon socket head screw Hexagon socket head screw Nut Impeller nut Locking sleeve Clamp Cable support Protection plug 1.4301 1.4301 HY22 Material G Motor DN 100 Shaft Bearing carrier Stator case
1)
UPA 150C
Carbon/graphite in PTFE Acrylnitril--Butadien--Rubber
HY22 NBR
C2 1.4408 1.4301 1.4301 1.4301 1.4401 1.4408 1.4305 1.4301 HY22 A2 NBR NBR 1.4301 NBR 1.4301 1.4408 1.4401 1.4404 1.4308 1.4301 A2 A4 A2 1.4401 1.4401 1.4404 1.4404 1.4408 1.4404 A4 A4 A4 1.4404 1.4404 A4 1.4401 1.4404 1.4404 1.4404 1.4404 1.4404
Bearings / Lubrication
Radial plain bearings: pump bearings lubricated by the fluid handled, motor bearings by the motors water fill. Axial thrust is balanced by a tilting-pad thrust bearing in the motor (lower end).
Type of Installation
Standard vertical installation. Depending on the number of stages, horizontal installation is also possible. Motor DN 100: In order to guarantee the dissipation of the motor heat it will be necessary to install a device guiding the flow along the motor (cooling jacket, flow inducer sleeve, etc.) in horizontal installation.
Drive
C2 1.4460 1.4462 1.4404 1.4409 1.4571 1.4571
C1 1.4305
1) 2)
-1.4301 -1.4301 --
Design . . . . . . . . . . . . . . Canned 1) or wet 2) submersible squirrel-cage motor, 2 poles Connection . . . . . . . . . . NEMA standard Type of enclosure . . . . IP 68 Frequency f . . . . . . . . . . 50 Hz Type of current . . . . . . . three-phase (3 ~) Rated voltage U . . . . . . up to 400V 1) or 690 V 2) Rated power PN . . . . . . . . up to 37 kW Frequency of starts . . . 20 / h 1) and 15 / h 2) Minimum delay before restarting . . . . . . 1 min 1) or 2 min 2) Motor design is in compliance with VDE regulations.
1) 2)
Description
1.4301 1.4305 1.4308 1.4401 1.4404 1.4408 1.4462 1.4571 JL -- 1030 A2 A4 CrNi steel CrNi steel CrNi steel CrNiMo steel CrNiMo steel CrNiMo steel CrNiMo steel CrNiMo steel cast iron CrNi steel CrNiMo steel
35
50 Hz Starting
Motor DN 100 . . . . . d.o.l. only (autotransformer or soft starter) Motor UMA 150D . . d.o.l. (autotransformer or soft starter) or star-delta
UPA 150C
Application Temperatures
The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = + 30 C. An indispensable requirement for this is a flow velocity of v = 0.2 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = + 50 C or for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.).
Variable Speed
The submersible borehole pumps can also be equipped with a speed control system to accommodate different operating points.
Fluids handled
The data refer to the chemical resistance of the materials. The relevant regulations/standards governing individual pump applications have to be complied with. The actual operating conditions must always be checked. For operating conditions or fluids which are not listed in this table, always contact the manufacturer. The fluid temperature must not exceed 50 C, unless stated otherwise. Fluid handled Spezification Max. Temperature material variant C1 Suspension p Water--sand mixture up to 20 mg/l Water--sand mixture up to 50 mg/l Water--sand mixture up to 200 mg/l Demineralised water De--ionised (fully desalinated) water De--alkalised water De--carbonised water Partly desalinated water Fire--fighting water Cooling g water Seawater and brackish water Surface water Closed cooling circuit Open cooling circuit Brackish water Seawater River water Lake water Dam water Process water Storm water Raw water Dirty water Swimming pool and bathing water Drinking / tap water Slightly contaminated water Seawater Fresh water Brewing water Ice water (brewery) Tap water Clean water Warm water (brewery) 25 C x x x x x x Sealing water Flushing water With strainer Without strainer 25 C 25 C x x x x x x x x x x x x x x x x x x x C2 x x x x x x x x x x x x x x x x x x x x x x x x x x x x
36
UPA 150C
Corrosion resistance The pump and motor are constructed of high--grade stainless steel as standard -- producing consistently high efficiency levels. Also available in higher grade CrNiMo steel for aggressive fluids.
Flexibility D Exchangeable connection variants D Check valve can be removed easily D Suitable for vertical installation in deep wells or horizontal installation D NEMA connection
Low operating costs High efficiency and low--loss check valve maintain long--term energy savings over the entire service lifetime of the unit.
High operating reliability and long service life Equipped with reinforced suction strainer, robust drive lantern and check valve made of investment cast stainless steel. Laser--welded impellers. Protected against thrust reversal.
37
UPA 150C
The KSB motor -- VDE-compliant, i.e., high level of electrical safety. -- Designed for max. pump power to protect unit from overloads.
Dynamically balanced rotor -- Ensures smooth running. Counter thrust bearing -- Reliable balancing of negative axial thrust. -- Impellers do not rub on the stage casings.
Tried and tested thrust bearing -- Water-lubricated self-aligning tilting-pad journal bearing. -- No-maintenance design suitable for maximum load-carrying capacity under continuous operation conditions. -- New materials combination (stainless steel / carbon) for high safety factor.
38
50 Hz
UPA 150C
39
UPA 150C
-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Rated power
PN kW
Motor Max. temperature of the fluid pumped v 0.2 m/s (0.0 m/s)
tmax 1) _C
Rated current
IN A
Efficiency
M %
Power factor
cos ------
Number x cross-section of conductors (use under water, 400 V and +30 _C)
d.o.l mm2 Y- mm2
H0 m 11.2 22 32.5 44 54 65 80 79 91 90 102 100 113 110 124 121 134 131 145 140 157 168 178 193 204 215 225
0.75 1.5 2.2 3.0 3.0 3.7 4.5 5.5 5.0 5.5 5.5 5.5 6.5 7.5 7.0 7.5 7.5 7.5 7.5 7.5 8.5 9.0 9.3 10.5 11.0 11.5 12.0
30 (30) 30 (30) 30 (30) 30 (30) 30 (30) 30 (30) 42 (39) 30 (20) 40 (36) 30 (20) 37 (33) 30 (20) 38 (34) 30 (20) 35 (31) 30 (20) 33 (28) 30 (20) 30 (24) 30 (20) 33 (28) 31 (25) 28 (22) 36 (32) 35 (30) 33 (28) 32 (26)
2.1 3.9 6.2 8.0 8.0 9.2 12.0 13.0 12.7 13.0 13.6 13.0 16.0 18.4 16.8 18.4 17.8 18.4 17.8 18.4 20.0 20.5 21.0 25.0 25.5 26.5 27.0
70.0 73.0 75.0 76.0 76.0 77.5 76.5 76.5 76.0 76.5 75.5 76.5 77.5 74.0 77.0 74.0 76.5 74.0 76.5 74.0 78.5 78.0 77.5 81.0 80.5 80.5 80.5
0.76 0.77 0.75 0.76 0.76 0.80 0.74 0.80 0.78 0.80 0.80 0.80 0.79 0.79 0.81 0.79 0.82 0.79 0.82 0.79 0.81 0.82 0.83 0.76 0.78 0.79 0.80
4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5
for motor DN UMA 337 397 458 518 579 639 700 760 821 881 942 1002 1063 -------------731 760 821 913 973 1034 1094 1155 1215 1276 1336 1397 1457 1518
1) Including check valve with threaded end and standard motor leads.
2) v = vertical / h = horizontal.
40
50 Hz
UPA 150C
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3
Tolerances to ISO 9906 Class 2 Annex A
Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
p:
Threaded end to DIN ISO 228, Part 1. Flanged end to DIN 2501, Part 1 Dmax
G 21/2
Lp
LA
41
UPA 150C
-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Motor Max. temperature of the fluid pumped v 0.2 m/s (0.0 m/s)
tmax 1) _C Motor lead 2), flat
Rated current
IN A
Efficiency
M %
Power factor
cos ------
Number x cross-section of conductors (use under water, 400 V and +30 _C)
d.o.l. mm2 Y- mm2
H0 m 236 246 256 269 280 290 305 315 326 336 347 357 373 383 394 404 415 425 441 451 483 504 542 583
13.0 13.0 13.0 14.0 15.0 15.0 16.0 16.5 17.0 17.5 18.0 18.5 20.0 20.0 21.0 22.0 22.0 22.0 24.0 24.0 26.0 26.0 29.0 30.0
30 (24) 29 (22) 28 (22) 33 (28) 32 (26) 30 (25) 32 (27) 31 (25) 30 (24) 29 (22) 27 (21) 26 (19) 33 (28) 33 (27) 32 (26) 31 (25) 30 (24) 29 (23) 36 (31) 35 (30) 33 (27) 31 (26) 33 (27) 30 (24)
29.0 29.0 29.0 30.5 32.5 32.5 36.5 37.0 38.0 39.0 39.5 40.5 44.0 44.0 46.0 47.5 47.5 47.5 52.0 52.0 55.0 55.0 63.0 65.0
80.0 80.0 80.0 82.0 81.5 81.5 82.5 82.0 82.0 82.0 82.0 81.5 83.5 83.5 83.5 83.5 83.5 83.5 85.0 85.0 84.5 84.5 84.5 84.5
0.81 0.81 0.81 0.82 0.83 0.83 0.78 0.79 0.79 0.80 0.81 0.81 0.79 0.79 0.80 0.81 0.81 0.81 0.80 0.80 0.82 0.82 0.80 0.80
4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0
for motor UMA 1578 1639 1699 1760 1820 1881 1941 2002 2062 2123 2183 2244 2304 2365 2425 2486 2546 2607 2667 2728
on request
1) Including check valve with threaded end and standard motor leads.
2) v = vertical / h = horizontal.
42
50 Hz
UPA 150C
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve
52 48 45 43 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21
Tolerances to ISO 9906 Class 2 Annex A
Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
p:
Threaded end to DIN ISO 228, Part 1. Flanged end to DIN 2501, Part 1 G 21/2 Dmax
Lp
LA
43
UPA 150C
-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Motor Max. temperature of the fluid pumped v 0.2 m/s (0.0 m/s)
tmax 1) _C Motor lead 2), flat
Rated current
IN A
Efficiency
M %
Power factor
cos ------
Number x cross-section of conductors (use under water, 400 V and +30 _C)
d.o.l. mm2 Y- mm2
H0 m
10.6 21.5 32.0 43.0 56.0 55.0 67.0 66.0 78.0 76.0 88.0 100.0 110.0 120.0 134.0 144.0 154.0 165.0 176.0 186.0 200.0
1.1 2.2 3.0 3.7 4.5 5.5 5.5 5.5 6.5 7.5 7.0 8.0 9.0 9.3 11.0 11.5 12.5 13.0 14.5 15.0 16.0
30 (30) 30 (30) 30 (30) 30 (30) 41 (38) 30 (20) 37 (33) 30 (20) 37 (33) 30 (20) 33 (29) 35 (30) 31 (26) 28 (22) 35 (31) 33 (28) 31 (25) 29 (22) 33 (28) 31 (25) 32 (27)
3.1 6.2 8.0 9.2 12.0 13.0 13.6 13.0 16.0 18.4 16.8 19.0 20.5 21.0 25.5 26.5 28.0 29.0 31.5 32.5 36.5
73.5 75.0 76.0 77.5 76.5 76.5 75.5 76.5 77.5 74.0 77.0 78.5 78.0 77.5 80.5 80.5 80.5 80.0 82.0 81.5 82.5
0.71 0.75 0.76 0.80 0.74 0.80 0.80 0.80 0.79 0.79 0.81 0.80 0.82 0.83 0.78 0.79 0.80 0.81 0.82 0.83 0.78
4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5
LA mm
incl motor incl.
mA kg
incl motor incl. dol d.o.l.
Dmax mm
dol d.o.l. Y Y-
Installation 2) v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h
UMA ----805 901 997 1093 1189 1285 1381 1477 1573 1669 1765 1861 1957 2053
UMA ----1505 1600 1715 1810 1940 2035 2130 2305 2400 2500 2595 2735 2830 2970
DN 18 23 27 36 44 46 51 ------------
UMA ----146 146 146 146 146 146 146 146 146 146 146 147 147 147
UMA ----148 148 148 148 148 148 148 148 148 148 148 148 148 148
1) Including check valve with threaded end and standard motor leads.
2) v = vertical / h = horizontal.
44
50 Hz
UPA 150C
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve
Tolerances to ISO 9906 Class 2 Annex A
Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
p:
Pump End G 3
The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) G 3 G 4 DN 65 DN 80 48 93 77 77 Dmax (mm) see page 44 185 200
Threaded end to DIN ISO 228, Part 1. Flanged end to DIN 2501, Part 1
G 3
Dmax
Lp
LA
45
UPA 150C
-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Motor Max. temperature of the fluid pumped v 0.2 m/s (0.0 m/s)
tmax 1) _C Motor lead 2), flat
Rated current
IN A
Efficiency
M %
Power factor
cos ------
Number x cross-section of conductors (use under water, 400 V and +30 _C)
d.o.l. mm2 Y- mm2
H0 m
210.0 220.0 230.0 244.0 254.0 265.0 275.0 289.0 299.0 309.0 320.0 330.0 345.0 355.0 365.0 376.0 389.0
17.0 18.0 18.5 20.0 21.0 22.0 22.0 24.0 24.0 25.0 26.0 26.0 28.0 29.0 30.0 30.0 32.0
30 (24) 29 (22) 27 (20) 33 (28) 32 (26) 31 (25) 29 (23) 36 (31) 35 (30) 34 (28) 32 (27) 31 (26) 34 (28) 33 (27) 32 (26) 31 (25) 46 (41)
3) Parallel cable
38.0 39.5 40.5 44.0 46.0 47.5 47.5 52.0 52.0 53.0 55.0 55.0 61.0 63.0 65.0 65.0 71.0
82.0 82.0 81.5 83.5 83.5 83.5 83.5 85.0 85.0 85.0 84.5 84.5 84.5 84.5 84.5 84.5 84.0
0.79 0.81 0.81 0.79 0.80 0.81 0.81 0.80 0.80 0.81 0.82 0.82 0.79 0.80 0.80 0.80 0.78
4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 3/4 x 4.0
3)
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0
LA mm
incl. motor
mA kg
incl. motor
Dmax mm
d.o.l. Y-
Installation 2)
UMA 2149 2245 2341 2437 2533 2629 2725 2821 2917 3013 3109 3205 3301 3397 3493 3589
UMA 3070 3165 3260 3445 3540 3640 3735 3935 4030 4125 4225 4320 4515 4610 4705 4805
UMA 105 107 108 118 119 121 123 133 135 136 138 140 150 152 153 155
UMA 147 147 147 147 147 147 147 149 149 149 149 149 149 149 149 149
UMA 148 148 148 148 148 148 148 149 149 149 149 149 149 149 149 149 v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3)
1) Including check valve with threaded end and standard motor leads.
2) v = vertical / h = horizontal.
46
50 Hz
UPA 150C
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve
Tolerances to ISO 9906 Class 2 Annex A
Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
p:
Pump End G 3
The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) G 3 G 4 DN 65 DN 80 48 93 77 77 Dmax (mm) see page 46 185 200
Threaded end to DIN ISO 228, Part 1. Flanged end to DIN 2501, Part 1
G 3
Dmax
Lp
LA
47
UPA 150C
-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Motor Max. temperature of the fluid pumped v 0.2 m/s (0.0 m/s)
tmax 1) _C Motor lead 2), flat
Rated current
IN A
Efficiency
M %
Power factor
cos ------
Number x cross-section of conductors (use under water, 400 V and +30 _C)
d.o.l. mm2 Y- mm2
H0 m
13.2 26.5 42.0 41.0 55.0 54.0 69.0 81.0 97.0 109.0 123.0 138.0 151.0 163.0 179.0 191.0
2.2 3.0 5.0 5.5 6.5 7.5 8.0 9.3 11.5 12.5 14.5 16.0 17.5 18.5 21.0 22.0
30 (30) 30 (30) 40 (36) 30 (20) 37 (32) 30 (20) 35 (30) 29 (23) 34 (29) 30 (25) 33 (28) 32 (27) 29 (23) 26 (19) 32 (26) 29 (23)
6.2 8.0 12.7 13.0 16.0 18.4 19.0 21.0 26.5 28.0 31.5 36.5 39.0 40.5 46.0 47.5
75.0 76.0 76.0 76.5 77.5 74.0 78.5 77.5 80.5 80.5 82.0 82.5 82.0 81.5 83.5 83.5
0.75 0.76 0.78 0.80 0.79 0.79 0.80 0.83 0.79 0.80 0.82 0.78 0.80 0.81 0.80 0.81
4 x 1.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5
LA mm
incl motor incl.
mA kg
incl motor incl. dol d.o.l.
Dmax mm
dol d.o.l. Y Y-
Installation 2)
UMA --664 777 890 1003 1116 1229 1342 1455 1568 1681 1794 1907
UMA --1365 1500 1640 1755 1945 2060 2220 2375 2490 2600 2805 2920
UMA --63.3 67.6 72.9 75.1 84.4 86.7 92.9 99.2 101.5 103.7 114.0 116.3
UMA --143 143 143 143 143 143 145 145 145 145 145 145
UMA --146 146 146 146 146 146 146 146 146 146 146 146 v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h
1) Including check valve with threaded end and standard motor leads.
2) v = vertical / h = horizontal.
48
50 Hz
UPA 150C
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve
Tolerances to ISO 9906 Class 2 Annex A
Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
p:
Pump End G 3
The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) G 3 G 4 DN 80 48 93 77 Dmax (mm) see page 48 200
Threaded end to DIN ISO 228, Part 1. Flanged end to DIN 2501, Part 1
G 3
Dmax
Lp
LA
49
UPA 150C
-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Motor Max. temperature of the fluid pumped v 0.2 m/s (0.0 m/s)
tmax 1) _C Motor lead 2), flat
Rated current
IN A
Efficiency
M %
Power factor
cos ------
Number x cross-section of conductors (use under water, 400 V and +30 _C)
d.o.l. mm2 Y- mm2
H0 m
207.0 219.0 232.0 248.0 261.0 276.0 289.0 301.0 314.0 327.0
24.0 26.0 26.0 29.0 30.0 32.0 33.0 35.0 36.0 37.0
35 (30) 33 (28) 31 (25) 33 (27) 31 (25) 45 (40) 44 (38) 42 (36) 41 (35) 39 (33)
3) Parallel cable
52.0 55.0 55.0 63.0 65.0 71.0 72.0 76.0 77.0 79.0
85.0 84.5 84.5 84.5 84.5 84.0 84.0 84.0 83.5 83.5
0.80 0.82 0.82 0.80 0.80 0.78 0.79 0.80 0.81 0.82
3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0
LA mm
incl. motor
mA kg
incl. motor
Dmax mm
d.o.l. Y-
Installation 2)
UMA 2020 2133 2246 2359 2472 2585 2698 2811 2924 3037
UMA 3135 3250 3360 3575 3690 3880 3995 4105 4220 4335
UMA 128.0 130.0 132.0 143.0 146.0 155.0 157.0 159.0 162.0 164.0
UMA 146 146 146 146 146 145 145 145 145 145
UMA 147 147 147 147 147 147 147 147 147 147 v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3) v 3)
1) Including check valve with threaded end and standard motor leads.
2) v = vertical / h = horizontal.
50
50 Hz
UPA 150C
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve
Tolerances to ISO 9906 Class 2 Annex A
Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
p:
Pump End G 3
The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) G 3 G 4 DN 80 48 93 77 Dmax (mm) see page 50 200
Threaded end to DIN ISO 228, Part 1. Flanged end to DIN 2501, Part 1
G 3
Dmax
Lp
LA
51
UPA 150C
-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Motor Max. temperature of the fluid pumped v 0.2 m/s (0.0 m/s)
tmax 1) _C Motor lead 2), flat
Rated current
IN A
Efficiency
M %
Power factor
cos ------
Number x cross-section of conductors (use under water, 400 V and +30 _C)
d.o.l. mm2 Y- mm2
H0 m
13.4 27.0 42.0 41.0 55.0 53.0 69.0 84.0 97.0 111.0 125.0 140.0 153.0 168.0 181.0
2.2 3.7 6.0 7.5 7.5 7.5 9.3 11.5 13.0 15.0 17.5 20.0 21.0 23.0 25.0
30 (30) 30 (30) 39 (35) 30 (20) 31 (26) 30 (20) 29 (23) 33 (28) 28 (22) 31 (25) 30 (24) 34 (29) 31 (25) 36 (31) 34 (28)
6.2 9.2 15.1 18.4 17.8 18.4 21.0 26.5 29.0 32.5 39.0 44.0 46.0 49.5 53.0
75.0 77.5 77.5 74.0 76.5 74.0 77.5 80.5 80.0 81.5 82.0 83.5 83.5 85.0 85.0
0.75 0.80 0.77 0.79 0.82 0.79 0.83 0.79 0.81 0.83 0.80 0.79 0.80 0.79 0.81
4 x 1.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 1.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0
LA mm
incl motor incl.
mA kg
incl motor incl. dol d.o.l.
Dmax mm
dol d.o.l. Y Y-
Installation 2)
UMA --664 777 890 1003 1116 1229 1342 1455 1568 1681 1794
UMA --1385 1495 1640 1830 1945 2105 2260 2465 2575 2795 2910
UMA --65.2 67.5 72.8 82.0 84.3 90.6 96.8 107.1 109.4 120.6 122.9
UMA --143 143 143 143 143 145 145 145 145 146 146
UMA --146 146 146 146 146 146 146 146 146 147 147 v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h
1) Including check valve with threaded end and standard motor leads.
2) v = vertical / h = horizontal.
52
50 Hz
UPA 150C
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve
Tolerances to ISO 9906 Class 2 Annex A
Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
p:
Pump End G 3
The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) G 3 G 4 48 93 Dmax (mm) see page 52
Threaded end to DIN ISO 228, Part 1. Flanged end to DIN 2501, Part 1
G 3
Dmax
Lp
LA
53
UPA 150C
-- Type of current / voltage . . . . . . . . . . . . . . . . . . . . . . . . . three-phase (3 ) / 400 V -- Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. (D) or star-delta (Y-)
Motor Max. temperature of the fluid pumped v 0.2 m/s (0.0 m/s)
tmax 1) _C Motor lead 2), flat
Rated current
IN A
Efficiency
M %
Power factor
cos ------
Number x cross-section of conductors (use under water, 400 V and +30 _C)
d.o.l. mm2 Y- mm2
H0 m
3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0
3/4 x 4.0 3)
LA mm
incl motor incl.
mA kg
incl motor incl.
Dmax mm
dol d.o.l. Y Y-
Installation 2)
1) Including check valve with threaded end and standard motor leads.
2) v = vertical / h = horizontal.
54
50 Hz
UPA 150C
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. Legend ... Hv : Head losses in the check valve
Tolerances to ISO 9906 Class 2 Annex A
Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
p:
Pump End G 3
The information given below is based on the model with check valve and threaded end. The changes in the main dimensions resulting from different threaded or flanged ends are specified in the table below. Overall length (mm) G 3 G 4 48 93 Dmax (mm) see page 54
Threaded end to DIN ISO 228, Part 1. Flanged end to DIN 2501, Part 1
G 3
Dmax
Lp
LA
55
50 Hz
UPA 150C
56
50 Hz Applications
Handling clean or slightly contaminated water ... -- in general water supply systems, -- in irrigation and spray irrigation systems, -- in pressure boosting systems, -- in emergency water supply systems, -- in installations for lowering and maintaining ground water levels. Also used in ... -- mining, -- sprinkler installations, -- fountains, etc. Permissible sand content in the fluid handled: 50 g/m3. Also suitable for aggressive seawater if supplied in material variant C3 (duplex).
UPA 200, 200B, 250C Submersible Borehole Pumps for Well Diameters of 200 mm ( 8 inches) and of 250 mm (10 inches)
Operating Data
Capacity Head Temperature of fluid handled Speed Q H t n up to 330 m3/h (92 l/s) up to 460 m up to +50 C 2900 rpm
Design
Single or multistage, single-entry centrifugal pumps in ring-section design. Mixed flow hydraulic systems with impellers that can be turned down. Stage casings connected by means of studs. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with non-return valve or connection branch on option. Both models available with either threaded or flanged end. Particularly suitable for vertical installation in narrow deep wells.
Designation (Example)
UPA 200 B -- 80 B / 5 d Type series Minimum well diameter (mm) Design status Capacity (m3/h) Impeller material1)
material variants other than basic variant (e.g. B = Bronze)
Product Features
--------Very sturdy design Suitable for installation in narrow deep wells High efficiency Motor designed for maximum pump output Low noise level For vertical or horizontal installation Check valve protected against blocking Pre-filled motor; no risk of contamination of the pumped water
Certification
Quality management certified to ISO 9001
57
UPA 250C-150 UPA 250C-120 UPA 200-14 UPA 200B-80 UPA 250C-250
UPA 200-11
UPA 200B-130
UPA 200-11
UPA 200-14
UPA 200B-80
UPA 250C-120
UPA 250C-150
UPA 250C-250
UPA 200B-130
Note: The diagram shows the QA range on offer. The pumps can be offered for any duty point within this range. The QB operating ranges of the individual pump sizes are given in the characteristic curves for diffrent stage numbers on the following pages. Selection charts or performance curves for UPA in material variant C3 (duplex) on request only. 58
G
Cast iron (JL1030) 1)
B
Bronze (CC480K--GS) 2)
Glass fibre reinforced NORYL (PPO) Glass fibre reinforced NORYL (PPO) Cr steel (1.4021) CrNiMo steel (1.4462)
Bearings / Lubrication
Plain bearing in the end stage, lubricated by the fluid handled. Axial thrust is balanced by a thrust bearing in the motor.
3410:8/3
Part No 106/108 143 171 211 232 503 529/545 751 849 917
Description Suction casing / Stage casing Suction strainer Diffuser Pump shaft Clockwise impeller Impeller wear ring Bearing sleeve / Bearing bush Valve body Sleeve coupling Tie bolt
59
G
Cast iron (JL1040) 1)
B
Bronze (CC480K-GS) 2)
G 5 and G 6 threaded ends depending on the size. DN 125 and DN 150 flanges available on option. Quality . . . . . . . . . . . 2-component high-build coating (epoxy resin base), approved for drinking water contact Coating structure . . Primer and top coat Film thickness . . . . 100 to 150 m Colour . . . . . . . . . . . ultramarine blue (RAL 5002)
Casing Impeller
200B
Coating (Standard)
250C
Glass fibre Bronze reinforced (CC480K-GS) 5) CrNiMo steel NORYL (1.4517) (PPO) 2) Bronze (CC480K-GS) Cr steel CrNiMo steel (1.4021) (1.4462) high-performance plastics CrNiMo steel (A4--70) CrNiMo steel (1.4538) CrNiMo steel (1.4462)
Type of Installation
In general, the pumps are installed vertically. Some models may also be installed horizontally depending on the number of stages and motor size.
Drive
Motor type . . . . . . . . . . . . . . . water-filled submersible squirrel-cage motor, 2 poles Enclosure . . . . . . . . . . . . . . . IP 68 Frequency . . . . . . . . . . . . . . . 50 Hz Type of current . . . . . . . . . . . three-phase (3~) Rated voltage U . . . . . . . . . . up to 500 V Rated power PN . . . . . . . . . . up to 250 kW Frequency of starts . . . . . . . 15/h 1), 10/h 2) and 5/h 3) Minimum delay before restarting . . . . . . . . . 1 min 1) and 3 min 2) 3) Motor design is in compliance with VDE regulations.
1) 2) 3)
G
CrNi steel (1.4305 6) / 1.4021 7) ) CrNiMo steel (1 4462) (1.4462)
C2
CrNiMo steel (1.4462) CrNiMo steel (1.4462) ---CrNiMo steel (1.4409) CrNiMo steel (1.4408) ----
C3
CrNiMo steel (1.4462) CrNiMo steel (1.4462) CrNiMo steel (1.4462)
200D 250D 300D Housing 150D 200D 250D 300D Stator case 150D 200D 250D 300D CrNi steel (1.4301) CrNi steel (1.4301) CrNiMo steel (A4--70) CrNiMo steel (1.4571) CrNi steel (1.4301) Cast iron (JL1040) 1) Cast iron ( ) 3) (JL1030)
CrNiMo steel (1.4539) ( ) CrNiMo steel (1.4517) CrNiMo steel (1.4539) CrNiMo steel (1.4462)
Motor UMA 150D Motors UMA 200D and 250D Motor UMA 300D
CrNiMo steel (1.4571) ---CrNiMo steel (A4--70) CrNiMo steel (A4--70) ----
Starting
D.o.l. (autotransformer or soft starter) or star-delta.
Variable Speed
The submersible borehole pumps can also be equipped with a speed control system to accommodate different operating points.
Application Temperatures
The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = +30 C. An indispensable requirement for this is a flow velocity of v = 0.2 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = +50 C or for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.).
1) 2) 3)
DIN mat. code: GG-25 DIN mat. code: CuSn10 DIN mat. code: GG-20
4) Wetted by fluid handled 5) for size 80B and 130B 6) only for size UMA 150D 22/21 7) only for size UMA 150D > 22/21
Bearings / Lubrication
Radial plain bearings; pump bearings lubricated by the fluid handled, motor bearings by the motors water fill. Depending on the number of stages, 1 intermediate bearing is fitted on the pump unit. Axial thrust is balanced by a tilting-pad thrust bearing in the motor (lower end).
60
50 Hz Design Features
Check valve with anti-blockage valve disc -- No jamming or tilting. -- Spring-loaded design makes for minimum valve closing times and prevents waterhammer. -- High operating reliability.
All wetted plastic components are approved for contact drinking water (BAM 1)) -- Coating, electric cables, seal elements, gaskets, etc. are absolutely fit for use in drinking water applications.
1) German Federal Institute for Materials Research
Robust wear rings -- Replaceable wear rings made of corrosion- and wear-resistant metal. -- Protection against wear in the clearance; easy servicing.
Enclosed pump bearing -- No-maintenance design, high wear resistance. -- For trouble-free long-term operation.
Integrated sand separator -- Tried and tested KSB patent r. -- Added protection from abrasive wear for shafts and bearing areas. -- Long service life and high operating reliability.
New: Energy-efficient hydraulic systems -- High efficiency and low energy costs.
Wear-resistant mechanical seal -- Long service life and high operating reliability.
The KSB motor -- VDE-compliant, i.e., high level of electrical safety. -- Designed for max. pump power to protect unit from overloads.
Counter thrust bearing -- Reliable balancing of negative axial thrust. -- Impellers do not rub on the stage casings.
Tried and tested thrust bearing -- Water-lubricated self-aligning tilting-pad journal bearing. -- No-maintenance design suitable for maximum load-carrying capacity under continuous operation conditions. -- New materials combination (stainless steel / carbon) for high safety factor.
H04004669
Reliable pressure balancing system -- Optimum rubber expansion diaphragm design. -- Enables installation at very low depths.
61
UPA 200
Pumps with submersible motors for . . . . . . . . . . . . . three-phase current (3~) / 400 V / d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h UPA 200 - 11/ ... + .. 1e + UMA 150D 5/21 1d + UMA 150D 5/21 1 + UMA 150D 5/21 2e + UMA 150D 5/21 2c + UMA 150D 5/21 2 3 4 5 6 7 8 9 + UMA 150D 7/21 + UMA 150D 9/21 + UMA 150D 13/21 + UMA 150D 15/21 + UMA 150D 18/21 + UMA 150D 22/21 + UMA 150D 26/21 + UMA 150D 26/21 3d + UMA 150D 7/21 4c + UMA 150D 13/21 5b + UMA 150D 13/21 6b + UMA 150D 15/21 H0 m 19 20 23 36 41 45 59 66 83 89 103 110 123 133 155 178 199 222 245 266 286 315
2)
Motor Rated power PN kW 2.5 2.5 3.5 4.5 5.5 6.0 7.0 9.0 10.0 12.0 12.5 14.5 15.0 17.5 21.0 24.0 26.0 29.0 32.0 35.0 37.0 42.0 Max. temperature of the fluid pumped v 0.2 m/s (= 0 m/s) tmax 1) _C 45 (42) 45 (42) 45 (42) 42 (39) 39 (35) 38 (34) 35 (30) 32 (27) 37 (33) 33 (28) 31 (35) 32 (37) 31 (35) 29 (23) 32 (27) 35 (31) 32 (26) 32 (26) 45 (40) 42 (36) 39 (33) 30 (25) Rated current IN A 9.5 9.5 10.6 12.0 13.6 15.1 16.8 20.5 24.0 27.0 28.0 31.5 32.5 39.0 46.0 52.0 55.0 63.0 71.0 76.0 79.0 85.0
3)
Motor lead 2), flat Efficiency M % 70.2 70.2 75.2 76.4 75.7 77.6 76.9 77.9 80.8 80.5 80.4 81.9 81.7 82.0 83.5 84.9 84.6 84.6 84.2 83.9 83.6 86.1 Power factor cos ---0.57 0.57 0.67 0.74 0.80 0.77 0.81 0.82 0.75 0.80 0.80 0.82 0.83 0.80 0.80 0.80 0.82 0.80 0.78 0.80 0.82 0.83 Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 4 x 6.0 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 6.0 3) Y- mm2 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 6.0
10 + UMA 150D 30/21 11 + UMA 150D 37/22 12 + UMA 150D 37/22 13 + UMA 150D 37/22 14 + UMA 200D 45/21
1) 4)
LP mm 515 515 515 580 580 580 645 645 710 710 775 775 840 840 905 970 1035 1100 1165 1230 1295 1360 1215 1215 1215 1280 1280 1300 1365 1395 1540 1540 1605 1650 1715 1760 1915 2085 2150 2315 2460 2525 2590 2590
LA mm
mA kg
Dmax mm D.o.l. 192 192 192 192 192 192 192 192 192 192 192 193 193 193 193 194 194 194 196 196 196 199
3)
Installation s a a o 2) v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v 3) v 3) v 3) v+h
G (Standard)
B (Special)
1225 1225 1225 1290 1290 1310 1375 1405 1550 1550 1615 1660 1725 1770 1925 2095 2160 2325 2470 2535 2600 2590
2)
G (Standard)
66 66 66 70 70 72 75 78 88 88 92 96 99 103 114 127 130 142 152 156 159 220
B (Special)
69 69 69 74 74 76 79 82 93 93 97 101 105 109 120 134 137 150 160 165 168 230
Y- 195 195 195 195 195 195 195 195 195 195 195 195 195 195 195 196 196 196 196 196 196 199
A mm 645 645 645 710 710 720 785 800 905 905 970 990 1055 1080 1190 1305 1370 1485 ---1755
Including check valve with threaded end and standard motor leads.
62
50 Hz UPA 200 - 11 / ..
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
UPA 200
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
Pump End G 3 / DN 80
The information is based on the model with check valve / connection branch and threaded end. The changes in the main dimensions of the flanged end model are specified in the table below. Check valve / connection branch with:
Threaded end G 3 Length mm 200 Length mm 200 (PN 10/16) 200 (PN 25/40) Flanged end DN 80 Outside diameter mm 200 200 Operating range: Qmin = 8 m3/h Qmax = End of characteristic curve
Threaded end to DIN ISO 228, Part 1 Flange mating dimensions to DIN 2501, Part 1
63
50 Hz UPA 200 -14 for Well Diameters of 200 mm (8 inches) and above
UPA 200
Pumps with submersible motors for . . . . . . . . . three-phase current (3~) / 400 V / d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h UPA 200 - 14/ ... + ... 1e + UMA 150D 5/21 1d + UMA 150D 5/21 1 + UMA 150D 5/21 2e + UMA 150D 7/21 2d + UMA 150D 7/11 2 3 4 5 6 7 8 9 + UMA 150D 9/21 + UMA 150D 13/21 + UMA 150D 18/21 + UMA 150D 22/21 + UMA 150D 26/21 + UMA 150D 30/21 + UMA 150D 37/22 + UMA 150D 37/22 3d + UMA 150D 13/21 4c + UMA 150D 15/21 5c + UMA 150D 18/21 6c + UMA 150D 22/21 7c + UMA 150D 26/21 H0 m 18 21 25 35 42 50 65 75 90 101 113 126 136 151 159 177 202 225 255 283 307 331
2)
Motor Rated power PN kW 3.0 3.5 4.5 6.0 7.0 8.5 10.5 12.5 14.5 17.0 18.0 21.0 22.0 25.0 26.0 30.0 34.0 37.0 44.0 48.0 52.0 55.0 Max. temperature of the fluid pumped v 0.2 m/s (= 0 m/s) tmax 1) _C 45 (42) 44 (41) 42 (39) 39 (35) 35 (31) 34 (29) 36 (32) 31 (25) 32 (27) 31 (25) 28 (21) 31 (26) 30 (24) 33 (28) 33 (28) 32 (26) 43 (38) 39 (33) 30 (24) 33 (27) 30 (24) 27 (21) Rated current IN A 10.0 10.6 12.0 15.1 16.8 20.0 25.0 28.0 31.5 38.0 39.5 46.0 47.5 53.0 55.0 65.0 74.0 79.0 89.0 98.0 104.0 109.0
3)
Motor lead 2), flat Efficiency M % 73.4 75.2 76.4 77.6 76.9 78.3 80.8 80.4 81.9 82.1 81.8 83.5 83.3 84.8 84.6 84.5 84.0 83.6 86.0 87.2 87.1 86.9 Power factor cos ---0.62 0.67 0.74 0.77 0.81 0.81 0.76 0.80 0.82 0.79 0.81 0.80 0.81 0.81 0.82 0.80 0.80 0.82 0.84 0.82 0.83 0.84 Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 4 x 6.0 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) Y- mm2 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0
10 + UMA 200D 45/21 11 + UMA 200D 55/21 12 + UMA 200D 55/21 13 + UMA 200D 55/21
1) 4)
LP mm 530 530 530 610 610 610 690 690 770 770 850 850 930 930 1010 1010 1090 1170 1250 1330 1410 1490
LA mm
mA kg
Dmax mm D.o.l. 192 192 192 192 192 192 192 192 193 193 193 193 193 194 194 194 196 196 199 199 199 199
3)
Installation 2)
A mm
G (Standard)
1230 1230 1230 1330 1330 1360 1520 1520 1645 1690 1770 1860 1940 2045 2125 2225 2385 2465 2480 2670 2750 2830
B (Special)
1240 1240 1240 1340 1340 1370 1530 1530 1655 1700 1780 1870 1950 2055 2135 2235 2395 2475 2480 2670 2750 2830
G (Standard)
67 67 67 73 73 76 87 87 95 99 106 114 117 126 130 139 150 151 213 237 241 245
2)
B (Special)
70 70 70 77 77 80 91 91 100 104 111 119 123 132 136 145 157 158 221 245 250 254
Y- 195 195 195 195 195 195 195 195 195 195 195 195 195 196 196 196 196 196 199 199 199 199 v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v 3) v 3) v+h v+h v+h v+h
660 660 660 750 750 765 885 885 985 1010 1090 1135 1215 1265 1345 1395 --1645 1780 1860 1940
Including check valve with threaded end and standard motor leads.
64
50 Hz UPA 200 - 14 / ..
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
UPA 200
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve. Pump efficiency p: (not considering check valve). NPSH: Net positive suction head required by the pump.
Pump End G 3 / DN 80
The information is based on the model with check valve / connection branch and threaded end. The changes in the main dimensions of the flanged end model are specified in the table below. Check valve / connection branch with
Threaded end G 3 Length mm 200 Length mm 200 (PN 10/16) 200 (PN 25/40) Flanged end DN 80 Outside diameter mm 200 200
Threaded end to DIN ISO 228, Part 1 Flange mating dimensions to DIN 2501, Part 1
65
Pumps with submersible motors for . . . . . . . . . . . . three-phase current (3~) / 400 V / d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h UPA 200B - 80/.. + ...
1g + UMA 150D 5/21 1f 1 2f 2 3f + UMA 150D 7/21 + UMA 150D 9/21 + UMA 150D 13/21 + UMA 150D 18/21 + UMA 150D 18/21 1d + UMA 150D 7/21 2g + UMA 150D 13/21 2d + UMA 150D 15/21
Efficiency M %
75.7 77.6 76.4 78.6 80.8 80.5 81.9 82.3 82.3 81.8 83.6 83.3 84.9 84.7 84.5 84.1 83.6 86.0 86.0 87.2 87.0 86.9 87.7 87.4 87.3 88.1 88.0
Power factor cos ---0.80 0.77 0.82 0.80 0.76 0.80 0.82 0.78 0.78 0.81 0.79 0.81 0.80 0.79 0.80 0.79 0.82 0.84 0.84 0.83 0.84 0.84 0.83 0.81 0.83 0.82 0.82
Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2
4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 4 x 6.0 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 10 3) 3/4 x 10 3) 3/4 x 10 3) 3/4 x 16 3) 3/4 x 16 3)
4)
H0 m
20 24 25 27 39 44 48 53 67 70 73 78 94 99 104 122 129 150 158 176 185 200 213 239 264 292 317
2)
Y- mm2
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 10 3/4 x 10 3/4 x 10 3/4 x 16 3/4 x 16
Parallel cable
+ UMA 150D 22/21 + UMA 150D 30/21 + UMA 150D 30/21 + UMA 150D 37/22 + UMA 200D 45/21 + UMA 200D 45/21 + UMA 200D 55/21 + UMA 200D 55/21 + UMA 200D 55/21 + UMA 200D 65/21 + UMA 200D 75/21 + UMA 200D 90/21
LA mm
mA kg
Dmax mm D.o.l.
193 193 193 193 193 193 194 194 194 194 194 194 195 195 195 198 198 201 201 201 201 201 205 205 205 211 211
mm
582 582 582 582 714 714 714 714 846 846 846 846 978 978 978 1110 1110 1242 1242 1374 1374 1506 1506 1638 1770 1902 2034
G (Standard)
1280 1300 1300 1330 1545 1545 1590 1635 1765 1765 1855 1855 2090 2190 2190 2405 2405 2475 2475 2715 2715 2845 2975 3200 3330 3645 3775
B (Special)
1295 1315 1315 1345 1555 1555 1600 1645 1780 1780 1870 1870 2105 2205 2205 2415 2415 2475 2475 2715 2715 2845 2975 3200 3330 3645 3775
G (Standard)
86 88 88 91 108 108 112 116 127 127 135 135 154 163 163 181 181 246 246 277 277 287 310 337 347 390 400
2) 4)
B (Special)
93 95 95 98 118 118 122 126 138 138 146 146 168 176 176 195 195 264 264 296 296 308 331 359 371 415 427
Y-
196 196 196 196 196 196 196 196 196 196 196 196 198 198 198 198 198 201 201 201 201 201 205 205 205 211 211
Installation 2)
v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v 3) v 3) v+h v+h v+h v+h v+h v+h v 4) v 4) v 3) 4) v 3) 4)
A mm
620 630 630 645 820 820 840 865 995 995 1040 1040 1225 1275 1275 --1550 1550 1735 1735 1865 1930 -----
Including check valve with threaded end and standard motor leads. Horizontal installation on request.
v = vertical and h = horizontal. Horizontal installation only with bearing pedestals of special design.
66
50 Hz UPA 200B - 80 / ..
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
Selection
The characteristic curves shown apply to the standard impeller material, i.e. Noryl. The performance data for the full impeller diameter and impeller diameter b for the given number of stages will only be achieved when the impellers are made of Noryl (PPO). For the special impeller material (bronze), please select the next higher number of stages. In this case, please refer to the characteristic curves individually prepared for the quotation. The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to pages 8. Legend ... Hv : Head losses in the check valve. Pump efficiency p: (not considering check valve). NPSH: Net positive suction head required by the pump.
The information is based on the model with check valve / connection branch and threaded end. The changes in the main dimensions of the flanged end model are specified in the table below. Check valve / connection branch with
Threaded end G 5 Length mm 200 Length mm 150 (PN 10/16) 150 (PN 25/40) Flanged end DN 125 Outside diameter mm 250 270
Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN 2501, Part 1
67
50 Hz UPA 200B - 130 for Well Diameters of 200 mm (8 Iinches) and above
Pumps with submersible motors for . . . . . . . . . . . . three-phase current (3~) / 400 V / d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h H0 m
17 20 23 25 34 37 39 42 44 48 58 63 66 70 72 84 89 92 96 110 114 122 135 142 146 164 171 196 219 245 267
2)
Efficiency M %
75.7 77.3 76.4 77.9 80.7 80.6 80.2 82.1 81.7 82.1 81.7 83.5 83.3 84.9 84.8 84.7 84.5 84.5 84.0 83.6 83.6 86.0 86.0 87.2 87.1 86.9 87.8 87.4 87.3 88.1 88.0
Power factor cos ---0.80 0.79 0.82 0.82 0.78 0.79 0.81 0.82 0.83 0.79 0.81 0.80 0.81 0.80 0.81 0.79 0.80 0.80 0.80 0.82 0.82 0.84 0.84 0.82 0.83 0.84 0.83 0.81 0.83 0.82 0.82
Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. Y- mm2 mm2
4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 4 x 6.0 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 16.0 3) 3/4 x 16.0 3)
4)
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 16.0 3/4 x 16.0
Parallel cable
2g + UMA 150D 13/21 2e + UMA 150D 13/21 2d + UMA 150D 15/21 2c 2 + UMA 150D 15/21 + UMA 150D 18/21
+ UMA 150D 22/21 + UMA 150D 26/21 + UMA 150D 30/21 + UMA 150D 37/22 + UMA 150D 37/22 + UMA 200D 45/21 + UMA 200D 45/21 + UMA 200D 55/21 + UMA 200D 65/21 + UMA 200D 75/21 + UMA 200D 75/21 + UMA 200D 90/21
LA mm G (Standard)
1295 1315 1345 1570 1615 1660 1805 1895 2000 2245 2325 2470 2405 2550 2660 2805 2935 3170 3315 3640 3785
mA kg G (Standard)
86 88 91 108 112 116 127 135 144 163 170 181 236 246 266 277 300 326 337 380 390
2) 4)
Dmax mm
D.o.l. Y-
mm
595 595 595 740 740 740 885 885 885 1030 1030 1175 1175 1320 1320 1465 1465 1610 1755 1900 2045
B (Special)
1305 1325 1355 1580 1625 1670 1815 1905 2010 2255 2335 2480 2405 2550 2660 2805 2935 3170 3315 3640 3785
B (Special)
94 96 99 118 122 126 138 146 156 176 183 195 252 264 284 296 319 347 359 403 415
Installation 2)
A mm
625 635 650 835 855 880 1025 1070 1120 1315 --1470 1615 1670 1815 1880 -----
1g 1e, 1c 1 2g, 2f, 2e 2d, 2c 2 3e 3d, 3c 3b, 3 4d, 4c, 4b 4 5c, 5b 5 6c 6b, 6 7b 7 8 9 10 11
1) 3)
193 193 193 193 194 194 194 194 195 195 198 198 201 201 201 201 205 205 205 211 211
196 196 196 196 196 196 196 196 198 198 198 198 201 201 201 201 205 205 205 211 211
v+h v+h v+h v+h v+h v+h v+h v+h v+h v+h v 3) v 3) v+h v+h v+h v+h v+h v 4) v 4) v 3) 4) v 3) 4)
Including check valve with threaded end and standard motor leads. Horizontal installation on request.
v = vertical and h = horizontal. Horizontal installation only with bearing pedestals of special design.
68
Selection
The characteristic curves shown apply to the standard impeller material, i.e. Noryl. The performance data for the full impeller diameter for the given number of stages will only be achieved when the impellers are made of Noryl (PPO). For the special impeller material (bronze), please select the next higher number of stages. In this case, please refer to the characteristic curves individually prepared for the quotation. The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
Threaded end to DIN ISO 228, Part 1 Flange mating dimensions to DIN 2501, Part 1
69
50 Hz UPA 250C - 120 for Well Diameters of 250 mm (10 inches) and above
Pumps with submersible motors for . . . . . . . . . . . . three-phase current (3~) / 400 V / d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h UPA 250C - 120/.. + ...
1l 1k + UMA 150D 9/21 + UMA 150D 13/21
Efficiency M %
77.9 80.8 80.5 82.1 82.2 81.8 83.5 84.9 84.6 84.6 84.0 83.9 83.6 86.1 86.0 87.1 87.0 87.8 87.4 87.4 87.3 88.1 88.7 88.6 89.2 89.5 90.0 89.9 90.6 90.7
Power factor cos ---0.82 0.76 0.80 0.82 0.79 0.81 0.80 0.80 0.82 0.80 0.80 0.80 0.82 0.83 0.84 0.83 0.84 0.83 0.81 0.81 0.83 0.82 0.81 0.83 0.85 0.85 0.81 0.83 0.85 0.86
Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2
4 x 2.5 4 x 2.5 4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 4 x 6.0 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 16.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 4) 3/4 x 35.0 4) 5) 3/4 x 35.0 4) 5) 2x3x70 + 1x35 4) 6) 2x3x70 + 1x35 4) 6)
5) 6)
Ho m
29 32 36 40 43 57 62 68 72 79 84 99 106 113 122 125 145 158 168 189 203 209 247 251 293 335 380 420 471 513
Y- mm2
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 16.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 35.0 5) 3/4 x 50.0 5) 3/4 x 50.0 5) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6)
+ UMA 150D 18/21 + UMA 150D 18/21 + UMA 150D 22/21 + UMA 150D 26/21 + UMA 150D 37/22 + UMA 150D 37/22 + UMA 200D 45/21 + UMA 200D 55/21 + UMA 200D 55/21 + UMA 200D 75/21 + UMA 200D 75/21 + UMA 200D 90/21 + UMA 250D 110/21 + UMA 250D 110/21 + UMA 250D 132/21 + UMA 250D 160/21 + UMA 250D 190/21 + UMA 300D 250/22
2h + UMA 150D 26/21 2d + UMA 150D 30/21 3h + UMA 150D 37/22 3e + UMA 200D 45/21
also see pages 3 and 60. 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing.
1 x 3-core, flat and 1 x 4-core, round 2 x 3-core, flat and 1 x 1-core, round
LA mm
mA kg G (Standard)
115 122 126 130 150 158 167 176 183 203 258 278 298 321 337 357 389 479 544 601 672 692 837 857
2) 4)
Dmax mm D.o.l.
230 230 230 230 230 230 232 232 233 233 235 235 235 239 239 239 244 257 257 257 266 266 304 304
mm
681 681 681 681 828 828 828 828 828 975 975 975 1122 1122 1122 1269 1269 1416 1563 1710 1857 2004 2151 2298
G (Standard)
1430 1510 1555 1600 1745 1835 1940 2040 2120 2270 2205 2315 2465 2595 2685 2830 3010 2945 3220 3480 3775 3925 4225 4370
B (Special)
1445 1525 1570 1615 1760 1850 1955 2055 2135 2280 2205 2315 2465 2595 2685 2830 3010 2945 3220 3480 3775 3925 4225 4370
B (Special)
128 135 139 143 167 175 185 193 200 225 282 302 326 349 365 389 421 514 583 644 719 744 891 915
Y-
232 232 232 232 232 232 233 233 233 233 235 235 235 239 239 239 244 257 257 266 280 280 304 304
Installation 2)
v+h v+h v+h v+h v+h v+h v+h v+h v 3) v 3) v+h v+h v+h v+h v+h v+h v 3) 4) v+h v 4) v 4) v 3) 4) v 3) 4) v 4) v 4)
A mm
710 750 775 795 945 990 1040 1090 --1245 1300 1450 1515 1560 1705 -1835 -------
Including check valve with threaded end and standard motor leads. Horizontal installation on request.
v = vertical and h = horizontal. Horizontal installation only with bearing pedestals of special design.
70
UPA 250C-120/...
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
The information is based on the model with check valve / connection branch and threaded end. The changes in the main dimensions of the flanged end model are specified in the table below. Check valve / connection branch with:
Threaded end G6 Length mm 229 Length mm 179 (PN 10/16) 179 (PN 25/40) Flanged end DN 150 Outside diameter mm 285 300 Operating range: Qmin = 20 m3/h Qmax = End of characteristic curve
Threaded end to DIN ISO 228, Part 1 Flange mating dimensions to DIN 2501, Part 1
250
400
71
50 Hz UPA 250C -150 for Well Diameters of 250 mm (10 inches) and above
Pumps with submersible motors for . . . . . . . . . . . . three-phase current (3~) / 400 V / d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h UPA 250C - 150/.. + ...
1l 1k 1 2k 2f 2c 2 + UMA 150D 13/21 + UMA 150D 15/21 + UMA 150D 22/21 + UMA 150D 30/21 + UMA 150D 37/22 + UMA 150D 37/22 + UMA 200D 45/21
Efficiency M %
80.7 82.1 81.7 83.3 84.7 84.5 84.0 83.6 86.0 86.0 87.2 86.9 87.7 87.7 87.4 87.3 88.2 88.1 88.6 88.6 88.5 89.2 89.1 89.0 89.4 90.0 89.8 90.7 90.7 90.7
Power factor cos ---0.78 0.82 0.81 0.81 0.79 0.80 0.80 0.82 0.84 0.84 0.83 0.84 0.83 0.84 0.82 0.83 0.81 0.82 0.82 0.83 0.84 0.85 0.86 0.86 0.85 0.81 0.83 0.86 0.87 0.87
Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2
4 x 2.5 4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 4 x 6.0 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 16.0 3) 3/4 x 16.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 4) 3/4 x 35.0 4) 5) 3/4 x 35.0
4) 5)
H0 m
27 32 38 41 64 68 73 77 82 99 105 112 118 121 146 152 158 162 192 197 202 230 236 241 275 286 325 373 413 453
Y- mm2
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 16.0 3/4 x 16.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 35.0 5) 3/4 x 50.0 5) 3/4 x 50.0 5) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6)
3h + UMA 200D 45/21 3g + UMA 200D 55/21 3d + UMA 200D 55/21 3b + UMA 200D 65/21 3 4c 4 5c 5 6c 6 7 8 9 11
1) 2)
+ UMA 200D 65/21 + UMA 200D 75/21 + UMA 200D 90/21 + UMA 250D 110/21 + UMA 250D 110/21 + UMA 250D 132/21 + UMA 250D 132/21 + UMA 250D 190/21 + UMA 250D 190/21 + UMA 300D 250/22 + UMA 300D 250/22
4) 6)
also see pages 3 and 60. 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing.
1 x 3-core, flat and 1 x 4-core, round 2 x 3-core, flat and 1 x 1-core, round
LA mm
mA kg
Dmax mm D.o.l.
230 230 230 230 232 233 235 235 235 239 239 244 257 257 257 266 266 304 304 304
mm
690 690 690 690 846 846 846 1002 1002 1002 1158 1158 1314 1470 1626 1626 1782 1938 2094 2250
G (Standard)
1520 1565 1610 1700 2060 2140 2075 2235 2345 2475 2720 2900 2845 3130 3395 3545 3700 4010 4165 4325
B (Special)
1530 1575 1620 1710 2075 2155 2075 2235 2345 2475 2720 2900 2845 3130 3395 3545 3700 4010 4165 4325
G (Standard)
120 124 128 136 173 180 235 254 274 297 332 364 452 515 571 622 641 785 804 822
2) 4)
B (Special)
133 137 141 149 189 196 253 275 295 318 356 388 479 546 605 656 678 823 845 867
Y-
232 232 232 232 233 233 235 235 235 239 239 244 257 257 266 280 280 304 304 304
Installation 2)
v+h v+h v+h v+h v+h v 3) v+h v+h v+h v+h v+h v 3) v+h v 4) v 4) v 3) 4) v 3) 4) v 4) v 4) v 4)
A mm
755 775 800 845 1105 -1110 1270 1325 1390 1590 -1730 --------
Including check valve with threaded end and standard motor leads. Horizontal installation on request.
v = vertical and h = horizontal. Horizontal installation only with bearing pedestals of special design.
72
UPA 250C-150/...
(Tolerances to ISO 9906 Class 2)
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
The information is based on the model with check valve / connection branch and threaded end. The changes in the main dimensions of the flanged end model are specified in the table below. Check valve / connection branch with:
Threaded end G 6 Length mm 229 Length mm 179 (PN 10/16) 179 (PN 25/40) Flanged end DN 150 Outside diameter mm 285 300 Operating range: Qmin = 30 m3/h Qmax = end of characteristic curve
Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN 2501, Part 1
250
400
73
50 Hz UPA 250C - 250 for Well Diameters of 250 mm (10 inches) and above
Pumps with submersible motors for . . . . . . . . . . . . three-phase current (3~) / 400 V / d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h UPA 250C - 250/.. + ...
1m + UMA 150D 18/21 1k 1f 1 2l + UMA 150D 18/21 + UMA 150D 22/21 + UMA 150D 26/21 + UMA 150D 37/22
Efficiency M %
82.1 81.7 83.5 84.6 84.1 83.9 83.6 86.0 87.1 86.9 87.7 87.5 87.3 87.3 88.1 88.7 88.6 88.5 89.2 89.1 89.0 89.3 89.9 89.8 90.6 90.7 90.7 91.2
Power factor cos ---0.79 0.81 0.80 0.82 0.79 0.80 0.82 0.84 0.83 0.84 0.83 0.81 0.83 0.83 0.82 0.81 0.83 0.84 0.85 0.86 0.86 0.86 0.82 0.83 0.85 0.86 0.87 0.86
Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2
4 x 4.0 4 x 4.0 4 x 4.0 4 x 6.0 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 4.0 4) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 16.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 4) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 2x3x70 + 1x35 4) 6) 2x3x70 + 1x35 4) 6) 2x3x70 + 1x35 4) 6) 6x1x95 + 1x95
5) 6) 7)
H0 m
26 29 32 38 51 55 60 70 75 87 94 103 109 120 131 142 147 164 176 182 204 218 248 256 288 299 335 374
Y- mm2
3/4 x 2.5 3/4 x 2.5 3/4 x 2.5 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 4.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 16.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 35 5) 3/4 x 50 5) 3/4 x 50 5) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6) 6x1x95 + 1x95 7)
2m + UMA 150D 37/22 2g + UMA 150D 37/22 2d + UMA 200D 45/21 2 3f 3 + UMA 200D 55/21 + UMA 200D 65/21 + UMA 200D 75/21 3h + UMA 200D 55/21 3d + UMA 200D 75/21 4g + UMA 200D 75/21 4e + UMA 200D 90/21 4c 4 5c 5 6 7c 7 8c 8 9
1) 2)
+ UMA 250D 110/21 + UMA 250D 110/21 + UMA 250D 132/21 + UMA 250D 132/21 + UMA 250D 160/21 + UMA 250D 190/21 + UMA 250D 190/21 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 250/22
4) 7)
also see pages 3 and 60. 3/4 = 1 x 3-core + 1 x 4-core, 90_ spacing.
1 x 3-core, flat and 1 x 4-core, round 2 x 3-core, flat and 1 x 1-core, round 7 x 1-core. round
LA mm
mA kg
Dmax mm D.o.l.
230 230 232 233 235 235 235 239 239 239 244 257 257 257 257 257 266 304 304 282
mm
709 709 709 884 884 884 1059 1059 1059 1234 1234 1234 1409 1409 1584 1584 1759 1934 2109 2284
G (Standard)
1630 1720 1825 2180 2115 2225 2400 2530 2620 2795 2975 2765 2940 3070 3245 3355 3680 4005 4180 4535
B (Special)
1640 1730 1835 2190 2115 2225 2400 2530 2620 2795 2975 2765 2940 3070 3245 3355 3680 4005 4180 4535
G (Standard)
128 136 145 180 235 255 274 297 313 332 364 434 453 497 516 553 623 767 786 883
3) 4)
B (Special)
137 145 155 192 249 269 291 314 330 353 385 454 476 520 542 579 652 798 820 920
Y-
232 232 233 233 235 235 235 239 239 239 244 257 257 257 257 266 280 304 304 282
Installation 2)
v+h v+h v+h v 3) v+h v+h v+h v+h v+h v+h v 3) v+h v+h v 4) v 4) v 4) v 3) 4) v 4) v 4) v 4)
A mm
800 845 895 -1130 1185 1360 1425 1470 1645 -1630 1805 --------
Including check valve with threaded end and standard motor leads. v = vertical and h = horizontal.
Horizontal installation on request. Horizontal installation only with bearing pedestals of special design.
74
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve. p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump.
Threaded end to DIN ISO 228, Part 1 Flange mating dimensions to DIN 2501, Part 1
250
400
75
50 Hz
76
50 Hz Fields of Application
Handling clean or slightly contaminated water in applications such as: -- general water supply, -- irrigation and spray irrigation, -- pressure boosting, -- lowering and maintaining ground water levels as well as -- drainage. Also used in mining, sprinkler installations, fountains etc. Permissible sand content in the fluid handled: 50 g/m3. Also suitable for aggressive seawater if supplied in material variant C3 (duplex).
UPA 300, 350 Submersible Borehole Pumps for well diameters of 300 mm (12 inches) and above and of 350 mm (14 inches) and above
Operating Data
Capacity Head Temperature of fluid handled Speed Q H t n up to 840 m3/h (234 l/s) up to 480 m up to +50 C 2900 rpm
Design
Single or multistage, single-entry centrifugal pump in ring-section design. For vertical and horizontal installation. Mixed flow hydraulic systems with impellers that can be turned down. Stage casings are connected by means of stud bolts. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with check valve or connection branch on option. Both models with threaded or flanged end. Particularly suitable for vertical installation in narrow deep wells.
Designation (Example)
UPA 300 -- 94 / 5 b Type series Minimum well diameter (mm) Capacity Qopt (l/s) Number of stages Reduced impeller diameter(s) Available automation products: Hyamaster hyatronic switch gear (for UPA 350)
77
on request
UPA 300-65
UPA 300-94
UPA 350-128
UPA 350-180
Note: The diagram shows the QA range on offer. The pumps can be offered for any duty point within this range. The QB operating ranges of the individual pump sizes are given in the characteristic curves for diffrent stage numbers on the following pages. Selection charts or performance curves for UPA in material variant C3 (duplex) in request only. 78
50 Hz Material Variants
UPA pump Casing
Coating (Standard)
B
Bronze (CC480K--GS) / Aluminium bronze 1) (CC333G--GS)
G
Cast iron (JL1030 5) ) / Nodular cast iron 1) (JS--1030 3) )
C3
CrNiMo steel (1.4517) CrNiMo steel (1.4517) CrNiMo steel (1.4462) CrNiMo steel (1.4138) SiC / SiC
Quality . . . . . . . . . . . 2-component high-build coating (epoxy resin base), approved for drinking water contact Coating structure . . Primer and top coat Film thickness . . . . 100 to 150 m Colour . . . . . . . . . . . ultramarine blue (RAL 5002)
Type of Installation
In general, the pumps are installed vertically. Some models may also be installed horizontally, depending on the number of stages and motor size.
Drive
UMA motor Shaft 200D 250D 300D Housing g 200D 250D 300D Stator case 200D 250D 300D Screws, b lt bolts and nuts 2)
1) 3)
G
CrNiMo steel (1.4462) Cast iron (JL1030) 3) Cast iron (JL1040) 1)
C2
CrNiMo steel (1.4462) ---CrNiMo steel (1.4408) ---CrNiMo steel (1.4571) ---CrNiMo steel (A4--70) ---2) In
C3
CrNiMo steel (1.4462) CrNiMo steel (1.4539) CrNiMo steel (1.4517) CrNiMo steel (1.4539) CrNiMo steel (1.4462) CrNiMo steel (1.4539) CrNiMo steel (1.4462)
Type . . . . . . . . . . . . . . . . . . . . . . . water-filled submersible squirrel-cage motor, 2 poles Type of enclosure . . . . . . . . . . . IP 68 Frequency . . . . . . . . . . . . . . . . . . 50 Hz Type of current . . . . . . . . . . . . . . three-phase (3~) Rated voltage U . . . . . . . . . . . . . up to 6000 V Rated power PN . . . . . . . . . . . . . up to 600 kW Frequency of starts . . . . . . . . . . 10 / h 1) and 5 / h 2) Minimum delay before re-starting . . . . . . . . . . . . 3 min Motor design is in compliance with VDE regulations.
1) 2)
UMA 200D and 250D motors UMA 300D motor and larger motors
Starting Methods
D.o.l. (autotransformer or soft starter) or star-delta.
Application Temperatures
The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = +30 C. An indispensable requirement for this is a flow velocity of v 0.2 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = +50 C or for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.).
Bearings / Lubrication
Radial plain bearings: pump bearings lubricated by the fluid pumped, motor bearings by the motors water fill. Depending on the pump size and number of stages, 1 or 2 intermediate bearings are fitted in the pump. Axial thrust is balanced by a tilting-pad thrust bearing in the motor (lower end).
79
50 Hz Design Features
Check valve with anti-blockage valve disc -- No jamming or tilting. -- Spring--loaded design makes for minimum valve closing times and prevents waterhammer. -- High operating reliability.
All wetted plastic components are approved for drinking water contact (BAM 1)) -- Coating, electric cables, seal elements, gaskets, etc. are absolutely fit for use in drinking water applications.
1) German Federal Institute for Materials Research
Robust wear rings -- Replaceable wear rings made of corrosion- and wear-resistant metal. -- Protection against wear in the clearance; easy servicing.
Enclosed pump bearing -- No-maintenance design, high wear resistance. -- For trouble-free long-term operation.
Stainless steel union elements -- All wetted bolts, screws and nuts are made of CrNiMo steel. -- High operating reliability. -- Easy to remove and re-use even after many years of operation.
Mixed-flow impellers -- Can be turned down. This means pump performance can be exactly matched to head requirements in the system. Stainless steel pump shaft -- Fully protected by impeller hubs and sleeves from direct wear caused by the fluid pumped.
Wear-resistant mechanical seal -- Long service life and high operating reliability. The KSB motor -- Efficiencies up to 91 %. -- VDE-compliant, i.e. high level of electrical safety. -- Designed for max. pump power to protect unit from overloads.
Counter thrust bearing -- Reliable balancing of negative axial thrust. -- Impellers do not rub on the stage casings.
Dynamically balanced rotor -- Ensures smooth running. Tried and tested thrust bearing -- Water-lubricated self-aligning tilting-pad journal bearing. -- No-maintenance design suitable for maximum load-carrying capacity under continuous operation conditions. -- New materials combination (stainless steel / carbon) for high safety factor.
3411:10
Reliable pressure balancing system -- Optimum rubber expansion diaphragm design. -- Enables installation at very low depths.
80
50 Hz
81
50 Hz UPA 300 - 65 for Well Diameters of 300 mm (12 inches) and above
Pumps with submersible motors for . . . . . . . . . . . . . three-phase current (3 ) / 400 V / d.o.l. (D) or star-delta (Y- ) starting
Pump + motor Pump Discharge head Q = 0 m3/h Rated power PN kW 16.0 20.0 23.0 27.0 34.0 40.0 45.0 54.0 60.0 70.0 72.0 82.0 88.0 95.0 110.0 110.0 120.0 130.0 145.0 145.0 165.0 190.0 180.0 205.0 225.0 265.0 300.0
3) 4)
Motor Max. temperature of the fluid pumped v 0.2 m/s ( = 0 m/s) tmax 1) _C 44 (42) 43 (40) 41 (38) 38 (34) 32 (26) 32 (27) 28 (21) 29 (23) 30 (25) 27 (20) 25 (18) 28 (22) 26 (18) 26 (19) 20 (11) 19 (10) 25 (17) 20 (10) 21 (12) 20 (11) 22 (13) 59 (53) 19 (9) 57 (51) 55 (49) 56 (49) 53 (46) Rated current IN A 43.5 48.5 53.0 59.0 70.0 82.0 90.0 108.0 120.0 143.0 146.0 167.0 177.0 191.0 215.0 215.0 229.0 245.0 276.0 276.0 325.0 359.0 349.0 382.0 414.0 491.0 546.0 Efficiency M % 83.0 84.6 85.2 85.5 85.4 86.2 86.0 87.0 87.8 87.4 87.4 88.2 88.1 88.7 88.5 88.5 89.2 89.1 89.4 89.4 90.0 90.5 89.8 90.6 90.7 91.2 91.2
5) 6) 7)
Motor lead 2), flat Power factor cos ---0.64 0.71 0.75 0.79 0.83 0.82 0.84 0.84 0.83 0.81 0.82 0.81 0.82 0.81 0.84 0.84 0.85 0.86 0.85 0.85 0.82 0.85 0.83 0.86 0.87 0.86 0.87 Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 16.0 3) 3/4 x 16.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 4) 3/4 x 25.0 4) 3/4 x 35 4) 5) 2x3x70 + 1x35 4) 6) 3/4 x 35 4) 5) 2x3x70 + 1x35 4) 6) 2x3x70 + 1x35 4) 6) 6x1x95 + 1x95 4) 7) 6x1x95 + 1x95 4) 7) Ymm2 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 16.0 3/4 x 16.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 35 5) 3/4 x 35 5) 3/4 x 50 5) 2x3x70 + 1x35 6) 3/4 x 50 5) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6) 6x1x95 + 1x95 7) 6x1x95 + 1x95 7)
Ho m 30 35 39 42 48 71 77 83 91 98 118 124 130 137 147 167 174 186 196 217 235 252 261 287 300 351 399
2m + UMA 200D 45/21 2l + UMA 200D 45/21 2g + UMA 200D 55/21 2d + UMA 200D 65/21 2 3k + UMA 200D 75/21 + UMA 200D 75/21
3h + UMA 200D 90/21 3e + UMA 200D 90/21 3d + UMA 250D 110/21 3 + UMA 250D 110/21
4g + UMA 250D 110/21 4e + UMA 250D 132/21 4b + UMA 250D 132/21 4 + UMA 250D 160/21
also see pages 3 and 79. 3/4 = 1 x 3-core and 1 x 4-core, 90_ spacing.
1 x 3-core, flat and 1 x 4-core, round. 2 x 3-core, flat and 1 x 1-core, round 7 x 1-core, round
mA kg
Installation 2)
A mm
mm 735 735 900 900 900 900 1065 1065 1095 1260 1260 1260 1425 1425 1425 1590 1590 1755 1920
G (Standard)
203 203 261 281 304 320 352 384 462 494 538 575 607 658 811 690 843 953 985
B (Special)
217 217 279 299 322 338 374 406 484 520 564 601 637 688 842 724 878 992 985 v+h v+h v+h v+h v+h v+h v+h v 3) v+h v+h v+h v 4) v 4) v 3) 4) v 4) v 3) 4) v 4) v 4) v 4)
945 945 1155 1210 1275 1320 1485 -1500 1665 1730 ---------
Including check valve with threaded end and standard motor leads. v = vertical / h = horizontal.
Horizontal installation on request. Horizontal installation only with bearing pedestals of special design.
82
50 Hz UPA 300 - 65 / ..
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
Selection
The information is based on the model with check valve and threaded end. The changes in the main dimensions of the flanged end model or the model with connection branch are specified in the table below. a) Check valve with:
Threaded end G 6 Length mm 255 Flanged end DN 150 Length mm 220 (PN 10/16) 228 (PN 25/40) Outside dia. mm 285 300
Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN 2501, Part 1
83
50 Hz UPA 300 - 94 for Well Diameters of 300 mm (12 inches) and above
Pumps with submersible motors for . . . . . . . . . . . three-phase current (3 ) / 400 V and d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h Rated power PN kW 29.0 32.0 36.0 42.0 45.0 54.0 62.0 74.0 82.0 95.0 110.0 110.0 125.0 130.0 145.0 165.0 175.0 205.0 225.0 280.0 335.0 315.0
3) 4)
Motor Max. temperature of the fluid pumped v 0.2 m/s (= 0 m/s) tmax 1) _C 37 (32) 34 (29) 30 (25) 31 (25) 27 (20) 29 (23) 29 (23) 25 (18) 28 (22) 26 (19) 20 (10) 20 (10) 24 (15) 20 (11) 20 (11) 22 (14) 19 (10) 57 (52) 55 (49) 54 (48) 52 (45) 54 (47) Rated current IN A 62 67 73 85 90 108 123 149 167 191 215 215 237 245 276 325 341 382 414 516 619 586 Efficiency M % 85.6 85.5 85.3 86.1 86.0 87.0 87.7 87.3 88.2 88.7 88.5 88.5 89.1 89.1 89.4 90.0 89.9 90.6 90.7 91.2 91.4 91.4
5) 6) 7)
Motor lead 2), flat Power factor cos ---0.80 0.82 0.84 0.83 0.84 0.84 0.83 0.83 0.81 0.81 0.84 0.84 0.86 0.86 0.85 0.82 0.83 0.86 0.87 0.86 0.86 0.85 Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 16.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 4) 3/4 x 35 4) 5) 3/4 x 35 4) 5) 2x3x70 + 1x35 4) 6) 2x3x70 + 1x35 4) 6) 6x1x95 + 1x95 6x1x95 + 1x95 6x1x95 + 1x95
4) 7) 4) 7) 4) 7)
Ho m 34 38 43 47 51 54 78 90 96 105 112 138 146 155 162 172 204 222 232 290 348 371
Y- mm2 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 10.0 3/4 x 10.0 3/4 x 16.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 35 5) 3/4 x 50 5) 3/4 x 50 5) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6) 6x1x95 + 1x95 7) 6x1x95 + 1x95 7) 6x1x95 + 1x95 7)
2m + UMA 200D 65/21 2h + UMA 200D 90/21 2d + UMA 250D 110/21 2 3k + UMA 250D 110/21 + UMA 250D 110/21
+ UMA 250D 160/21 + UMA 250D 190/21 + UMA 250D 190/21 + UMA 300D 250/22 + UMA 300D 250/22 + UMA 300D 300/22 + UMA 300D 400/22
also see pages 3 and 79. 3/4 = 1 x 3-core and 1 x 4-core, 90_ spacing.
1 x 3-core, flat and 1 x 4-core, round. 2 x 3-core, flat and 1 x 1-core, round 7 x 1-core, round
mm
775 775 775 775 775 775 950 950 950 980 980 1155 1155 1155 1155 1155 1330 1330 1330 1505 1680 1855
mm
1915 1915 1915 2005 2005 2115 2420 2510 2690 2510 2510 2685 2815 2815 2925 3075 3250 3405 3405 3760 4055 4230
G (Standard)
227 227 227 253 253 273 329 345 377 450 450 483 527 527 564 615 648 797 797 908 993 1026
3) 4)
B (Special)
245 245 245 271 271 291 352 368 400 473 473 511 555 555 592 643 681 831 831 947 1037 1075
Installation 2) v+h v+h v+h v+h v+h v+h v+h v+h v 3) v+h v+h v+h v+h v+h v+h v 3) 4) v 3) 4) v 4) v 4) v 4) v 3) 4) v 3) 4)
mm
960 960 960 1005 1005 1060 1300 1345 -1360 1360 1535 1600 1600 1655 --------
Including check valve with threaded end and standard motor leads. v = vertical / h = horizontal.
Horizontal installation on request. Horizontal installation only with bearing pedestals of special design.
84
50 Hz UPA 300 - 94 / ..
The characteristic curves shown are for preliminary selection only. Exact selection data will be provided in our quotation.
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
The information is based on the model with check valve and threaded end. The changes in the main dimensions of the flanged end model or the model with connection branch are specified in the table below. a) Check valve with:
Threaded end G 8 Length mm 290 Flanged end DN 200 Length mm 240 (PN 10) 240 (PN 16) 244 (PN 25) Outside dia. mm 340 340 360
Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN 2501, Part 1
385
85
50 Hz UPA 350 - 128 for Well Diameters of 350 mm (14 inches) and above
Pumps with submersible motors for . . . . . . . . . . . . three-phase current (3~) / 400 V and d.o.l. (D) or star-delta (Y-) starting
Pump + motor Pump Discharge head Q = 0 m3/h Rated power PN kW 35.0 44.0 55.0 64.0 75.0 88.0 105.0 110.0 120.0 132.0 150.0 175.0 210.0 240.0 300.0 355.0 400.0
3) 4)
Motor Max. temperature of the fluid pumped v 0.2 m/s ( = 0 m/s) tmax 1) _C 31 (25) 28 (22) 27 (20) 28 (22) 23 (15) 25 (18) 22 (14) 19 (10) 24 (16) 18 (9) 18 (9) 19 (10) 57 (51) 54 (47) 52 (45) 50 (42) 45 (35) Rated current IN A 72 89 109 127 151 177 208 215 229 249 284 341 389 439 546 652 728 Efficiency M % 85.3 86.0 86.9 87.7 87.3 88.1 88.6 88.5 89.2 89.0 89.3 89.9 90.7 90.7 91.2 91.4 91.2
5) 6) 7)
Motor lead 2), flat Power factor cos ---0.83 0.84 0.84 0.84 0.83 0.82 0.83 0.84 0.85 0.86 0.86 0.83 0.86 0.87 0.87 0.86 0.87 Number x cross-section of conductors (use under water, 400 V and +30 _C) D.o.l. mm2 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 6.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 16.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0
3)
Ho m 40 45 52 57 63 69 75 104 109 117 126 138 153 196 228 280 302
Y- mm2 3/4 x 6.0 3/4 x 6.0 3/4 x 6.0 3/4 x 10.0 3/4 x 10.0 3/4 x 16.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 35 5) 3/4 x 50 5) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6) 6x1x95 + 1x95 7) 6x1x95 + 1x95 7) 6x1x95 + 1x95 7)
also see pages 3 and 79. 3/4 = 1 x 3-core and 1 x 4-core, 90_ spacing.
1 x 3-core, flat and 1 x 4-core, round. 2 x 3-core, flat and 1 x 1-core, round 7 x 1-core, round
mA kg
Installation s a a o 2) 265 291 311 334 350 382 454 502 546 546 583 634 793 840 918 1018 1018 v+h v+h v+h v+h v+h v 3) v+h v+h v+h v+h v+h v 3) 4) v 4) v 4) v 4) v 3) 4) v 3) 4)
A mm 1020 1065 1120 1185 1230 -1215 1415 1480 1480 1535 -------
mm 898 898 898 898 898 898 898 1098 1098 1098 1098 1098 1108 1308 1308 1508 1508
G (Standard)
243 269 289 312 328 360 432 474 518 518 555 606 764 806 884 978 978
B (Special)
Including check valve with threaded end and standard motor leads. v = vertical / h = horizontal.
Horizontal installation on request. Horizontal installation only with bearing pedestals of special design.
86
Selection
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
The information is based on the model with check valve and threaded end. The changes in the main dimensions of the flanged end model or the model with connection branch are specified in the table below. a) Check valve with:
Threaded end G 8 Length mm 328 Flanged end DN 200 Length mm 278 (PN 10) 278 (PN 16) Outside dia. mm 340
Threaded end to DIN ISO 228, Part 1 Flange mating dimensions to DIN 2501, Part 1
1) DN 250 check valve (with flanged end only) on request. For relevant head losses see HV curve plotted over Q.
87
50 Hz UPA 350 - 180 for Well Diameters of 350 mm (14 inches) and above
Pumps with submersible motors for . . . . . . . . . . . . three-phase current (3~) / 400 V and d.o.l. (D) or star-delta (Y- ) starting
Pump + motor Pump Discharge head Q = 0 m3/h Rated power PN kW 54.0 62.0 65.0 75.0 86.0 100.0 130.0 132.0 150.0 165.0 180.0 210.0 240.0 320.0 310.0 345.0
3) 4)
Motor Max. temperature of the fluid pumped v 0.2 m/s ( = 0 m/s) tmax 1) _C 29 (23) 30 (24) 28 (21) 24 (16) 27 (20) 25 (17) 22 (13) 18 (9) 20 (11) 22 (14) 18 (9) 57 (51) 53 (47) 54 (47) 54 (47) 51 (44) Rated current IN A 108 123 129 151 173 199 245 249 284 325 349 389 439 595 580 634 Efficiency M % 87.0 87.7 87.7 87.3 88.1 88.6 89.1 89.0 89.3 90.0 89.8 90.7 90.7 91.4 91.4 91.4 Power factor cos ---0.84 0.83 0.84 0.83 0.82 0.82 0.86 0.86 0.86 0.82 0.83 0.86 0.87 0.85 0.85 0.86
5) 6) 7)
Motor lead 2), flat Number x cross-section of conductors (use under water, 400 V and +30_C) D.o.l. mm2 3/4 x 6.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 10.0 3) 3/4 x 16.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 3) 3/4 x 25.0 4) 3/4 x 35 4) 5) 3/4 x 35
4) 5)
Y- mm2 3/4 x 6.0 3/4 x 10.0 3/4 x 10.0 3/4 x 10.0 3/4 x 16.0 3/4 x 25.0 3/4 x 25.0 3/4 x 25.0 3/4 x 35 5) 3/4 x 50 5) 3/4 x 50 5) 2x3x70 + 1x35 6) 2x3x70 + 1x35 6) 6x1x95 + 1x95 7) 6x1x95 + 1x95 7) 6x1x95 + 1x95 7)
2x3x70 + 1x35 4) 6) 2x3x70 + 1x35 4) 6) 6x1x95 + 1x95 4) 7) 6x1x95 + 1x95 4) 7) 6x1x95 + 1x95 4) 7)
also see pages 3 and 79. 3/4 = 1 x 3-core and 1 x 4-core, 90_ spacing
1 x 3-core, flat and 1 x 4-core, round. 2 x 3-core, flat and 1 x 1-core, round 7 x 1-core, round
LA
mm 2240 2370 2370 2460 2640 2425 2755 2755 2865 3015 3015 3180 3380 3680 3880 3880
Dmax mm
D.o.l 322 320 320 320 324 334 334 334 334 343 343 360 360 341 341 341 Y- 322 320 320 320 324 334 334 334 343 357 357 360 360 341 341 341
3) 4)
mA kg
Installation 2)
A
mm
mm 898 898 898 898 898 898 1098 1098 1098 1098 1098 1108 1308 1308 1508 1508
G (Standard)
289 312 312 328 360 432 518 518 555 606 606 764 806 936 978 978
B (Special)
311 334 334 350 382 454 546 546 583 634 634 793 840 970 1018 1018 v+h v+h v+h v+h v 3) v+h v+h v+h v+h v 3) 4) v
3) 4)
v 4) v 4) v 3) 4) v 3) 4) v 3) 4)
Including check valve with threaded end and standard motor leads. v = vertical / h = horizontal.
Horizontal installation on request. Horizontal installation only with bearing pedestals of special design.
88
The pressure losses Hv in the check valve are not considered in the pump characteristic curves. For more details and a selection example refer to page 8. Legend ... Hv : Head losses in the check valve p: Pump efficiency (not considering check valve) NPSH: Net positive suction head required by the pump
Selection
The information is based on the model with check valve and threaded end. The changes in the main dimensions of the flanged end model or the model with connection branch are specified in the table below. a) Check valve with:
Threaded end G 8 Length mm 328 Flanged end DN 200 Length mm 278 (PN 10) 278 (PN 16) Outside dia. mm 340 Operating range: Qmin = 120 m3/h Qmax = End of characteristic curve
Threaded end to DIN ISO 228, Part 1. Flange mating dimensions to DIN 2501, Part 1
1) DN 250 check valve (with flanged end only) on request. For relevant head losses see HV curve plotted over Q.
89
50 Hz
90
50 Hz Applications
Handling clean and raw water in applications such as: -- general water extraction / supply, -- irrigation and spray irrigation, -- lowering and maintaining ground water levels in open-cast mines, -- dewatering and gallery drainage in underground mines. Use in pressure-boosting as well as for offshore and cavern applications, etc. Permissible sand content in the fluid handled: 50 g/m3.
BSX - BSF Submersible Borehole Pumps for Well Diameters of 400 mm (16 inches) and above
Operating Data
Capacity Head Temperature of fluid handled Speed Q H t n up to 2200 m3/h (610 l/s) up to 240 m up to + 50 oC 1450 rpm
Design
Single- or multi-stage, single-entry centrifugal pumps in ring-section design. For vertical and horizontal installation. Mixed flow hydraulic systems, also available with reduced impeller diameters. Stage casings connected by means of studs. Suction casing between pump and motor equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with check valve or connection branch on option. Both models with flanged end. Particularly suitable for installation in narrow deep wells.
Designation (Example)
............................. B R Type series Min. well diameter in mm 1) Suction impeller Code for hydraulic system Number of stages Reduced impellers diameters
1)
Z S
535 / 5 a
X = 400 mm (16 inches), Y = 450 mm (18 inches), Z = 500 mm (20 inches), E = 600 mm (24 inches), F = 650 mm (26 inches)
Product Features
--------Very sturdy design Suitable for installation in narrow deep wells High efficiency Motor designed for maximum pump output Low noise level For vertical or horizontal installation Check valve protected against blocking Pre-filled motor; no risk of contamination of the handled water
Certification
Quality management certified to ISO 9001
91
U.S.gpm 700
1000
1400 1400
2000 2000
3000
6000 6000
Imp.g.p.m. 1000
1000
BRY 504 BRZS 535 BRE 555 BSF 586
500 400
100 80 60 50 40 30
300 H ft 200
100 80
20 15
60
40 10 200 40 60 300 80 400 100 500 Q l/s Q m3/h 200 1000 300 400 2000 600 3000 800
3430:80
Note: The diagram shows the QA range on offer. The pumps can be offered for any duty point within this flow range.
92
50 Hz Materials
G Pump ... Casing Impeller Shaft Wear rings Bearings Cast iron JL1030 (GG-20) Cr steel (1.4021) Bronze (2.1090) Cr steel (1.4021) annealed / special bronze Alu bronze (G-CuAl11Ni) / special bronze Bronze (G-CuSn10) B
BSX - BSF
Drive
Type . . . . . . . . . . . . . . . . . . . . . . . water-filled submersible squirrel-cage motor, 4 poles Type of enclosure . . . . . . . . . . . IP 68 Frequency . . . . . . . . . . . . . . . . . . 50 Hz Type of current . . . . . . . . . . . . . . three-phase (3~) Rated voltage U . . . . . . . . . . . . . up to 6000 V Rated power PN . . . . . . . . . . . . . up to 2000 kW Frequency of starts . . . . . . . . . . 5 / h Minimum delay before re-starting 3 min Motor design is in compliance with VDE regulations.
Motor ... Shaft Cast parts Stator case CrNiMo steel (1.4462) Cast iron JL1040 (GG-20) Bronze (G-CuSn10)
Starting
Low voltage (U 1000 V): direct on line (without or with autotransformer or soft starter) and star-delta starting. High voltage (U > 1000 V): only direct on line.
Bearings / Lubrication
Radial plain bearings: pump bearings lubricated by the fluid handled, motor bearings by the motors water fill. Depending on the pump size and number of stages, 1 or 2 intermediate bearings are fitted in the pump. Axial thrust is balanced by a tilting-pad thrust bearing in the motor (lower end).
Application Temperatures
The submersible borehole pumps are, as a standard, suitable for use in water with temperatures of up to t = +30 C. An indispensable requirement for this is a flow velocity of v 0.2 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperatures of up to t = +50 C or for operation without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.).
Type of Installation
In general, the pumps are installed vertically. Some models may also be installed horizontally depending on the number of stages and motor size.
93
50 Hz Design Features
BSX - BSF
Check valve with antiblockage valve disc -- No jamming or tilting. -- Spring-loaded design makes for minimum valve closing times and prevents waterhammer.
Coating and electric cable suitable for use with drinking water (BAM)1) -- Absolutely fit for use in drinking water applications.
1) German Federal Institute for Materials Research
Enclosed pump bearing -- No-maintenance design, high wear resistance. -- For troublefree long-term operation. Mixed flow impellers -- Can be turned down. This means pump performance can be exactly matched to head requirements in the system. -- Impellers are fixed with keys for reliable power transmission. This simplifies assembly and dismantling. Stainless steel pump shaft -- Fully protected by impeller hubs and sleeves from direct wear caused by the fluid pumped.
Robust wear rings -- Replaceable wear rings (fitted with casing and impeller wear rings as a standard) made of wear and corrosion-resistant metal. -- Protection against wear in the clearance; easy servicing.
Stainless steel union elements -- All wetted bolts, screws and nuts are made of CrNiMo steel. -- High operating reliability and simplified dismantling.
KSB submersible motor -- VDE-compliant, i.e., high level of electrical safety. -- Designed for max. pump power to protect unit from overloads.
Dynamically balanced rotor -- Ensures smooth running. Counter thrust bearing -- Reliable balancing of negative axial thrust. -- Impellers do not rub on the stage casings. Reliable pressure balancing system -- Optimum rubber expansion diaphragm design. -- Enables installation at very low depths.
3411:11
Tried and tested thrust bearing -- Water-lubricated self-aligning tilting-pad journal bearing. -- No-maintenance design suitable for maximum load-carrying capacity under continuous operation conditions.
94
50 Hz Applications
Handling clean and raw water in applications such as: -- general water extraction / supply, -- irrigation and spray irrigation, -- lowering and maintaining ground water levels in open-cast mines, -- dewatering and gallery drainage in underground mines. Use in pressure-boosting as well as for offshore and cavern applications, etc. Permissible sand content in the fluid handled: 50 g/m3.
UPZ
Submersible Borehole Pumps for Well Diameters of 500 mm (20 inches) and above
Operating Data
Capacity Head Supply voltage Temperature of fluid handled Speed Q H U t n up to 2,200 m3/h (612 l/s) up to 1,500 m up to 6,600 V up to +40 oC 2900 rpm and 1450 rpm
Design
Multistage, double-entry ring-section pump with back-to-back impeller arrangement. For vertical installation. Radial and mixed-flow hydraulic systems with impellers that can be turned down. Half the flow enters the pump through the lower suction casing, the other half through the upper suction casing. The upper half of the pump unit is surrounded by a pressure shroud (outer shell). The two flows are collected by the channel created by the shroud and carried into the upper suction casing, which is equipped with two discharge branches. This configuration is designed to ensure full axial thrust balancing. The casing components (stage casings) are connected by means of round tie bolts. The two suction casings are equipped with strainers to protect the pump from coarse particles in the fluid. Flanged pump end. Check valve with flanged end available on request. Particularly suitable for installation in narrow deep wells.
Certification
Quality management certified to ISO 9001
95
U.S.gpm
2000 1500 UPZ ...
500
1000 1000
2000 2000
5000 5000
10000
1000
n = 1450 rpm
3000
H m
500 400 300 n = 2900 rpm
2000
H ft
1000 800 700 600 500 400
200 150
100
300
200 50 40 50 20 100 30 Q m3/h 200 50 300 400 500 100 Q l/s 200 1000 300 2000 500
3470:1
Note: The diagram shows the QA range on offer. The pumps can be offered for any duty point within this flow range.
96
50 Hz Materials
The choice of materials depends on the flow rate and discharge head. Component Pump Casing Cast iron (GJL-200) Nodular cast iron (GJS-600) Bronze (CuSn10) Aluminium bronze (CuAl10Ni) CrNi steel Bronze (CuSn10) Aluminium bronze (CuAl10Ni) CrNi steel CrNi steel (1.4057) CrNiMo steel (1.4462) Aluminium bronze (CuAl10Ni) CrNiMo steel Chrome steel (1.4021), hard chrome plated / special bronze or other special materials CrNiMo steel Material
UPZ
Coating (Standard)
For cast iron models only. Quality . . . . . . . . . . . 2-component high-build coating (epoxy resin base), approved for drinking water contact. Coating structure . . Primer and top coat. Film thickness . . . . 100 to 150 m. Colour . . . . . . . . . . . ultramarine blue (RAL 5002).
Type of Installation
In general, the pumps are installed vertically.
Drive
KSB submersible squirrel-cage motor, 2 or 4 poles. Three-phase current (3~). For supply voltages up to U = 6600 V. Water-filled motor. The water fill lubricates the bearings and cools the windings sealed with water-tight insulation material. Internal cooling circuit. The shaft is sealed by lip seals or a mechanical seal protected from ingress of sand. Pressure differences between motor and environment are equalized by a rubber expansion diaphragm in the motor. Motor design is in compliance with VDE regulations.
Steel (1.0503+N), protected Cast iron (GJL-200) Bronze (CuSn10) Aluminium bronze (CuAl10Ni) CrNi steel St 37, CrNiMo steel CrNiMo steel
Starting
Low voltage (U 1000 V): d.o.l (without or with autotransformer or soft starter) and star-delta (Y-- ) starting. High voltage (U > 1000 V): d.o.l. starting only.
Bearings / Lubrication
Pump: 1 radial plain bearing in each suction casing. Depending on the pump size and number of stages, 1 additional intermediate bearing each in the two pump halves. Lubricated by the fluid pumped. Motor: 2 radial plain bearings. Residual axial thrust is balanced by 1 self-aligning tilting-pad thrust bearing in the motor (lower end). Lubricated by the motors water fill.
Variants Available
------Other material variants Higher fluid temperatures More wear-resistant designs Models with cooling, suction or pressure shroud Special coating Special explosion protection up to 6 kV
97
50 Hz Design Features
UPZ
Robust wear rings -- Replaceable wear rings made of wear- and corrosion-resistant metal. -- Protection against wear in the clearance; easy servicing. Pump shroud -- Slim, low-weight design. -- High operating reliability because of simple sealing of high-pressure section. Impellers -- Can be turned down. -- This means pump performance can be matched exactly to head requirements in the system. Stainless steel union elements -- All wetted bolts, screws and nuts are made of CrNiMo steel. -- High operating reliability.
Enclosed pump bearing -- No--maintenance design, high wear resistance. -- For trouble-free long-term operation.
Stainless steel pump shaft -- Fully protected by impeller hubs and sleeves from direct wear caused by the fluid pumped.
Double-entry design with impellers in back-to-back arrangement -- Low wear thanks to low velocities in the pump and use of special materials. -- Designed to ensure full hydraulic thrust balancing, irrespective of any wear in the sealing clearances. -- Considerably reduced load on the thrust bearing. -- This allows high discharge heads at relatively large flow rates. Circulation cooling through double shroud -- Low temperature rise
Wear-resistant mechanical seal -- Long service life and high operating reliability.
Motor can be filled with drinking water -- Simply top up whenever needed. High efficiency M -- Reduced operating costs thanks to optimized windings.
Winding insulation (J2) -- Cu--VPE--PA material makes for maximum heat resistance.
Tried and tested thrust bearing -- New materials combination (stainless steel / carbon) for high safety factor. Sealing elements -- All joints sealed by O-rings. Pressure--proof up to a differential pressure of 16 bar.
Reliable pressure balancing system -- Optimum selection thanks to generously sized rubber diaphragm. -- Enables installation at very low depths.
98
Amount E Euro
Submersible borehole pump(s) type S 100D for well diameters of 100 mm (4 inches) and above Make: KSB Pump + motor: S 100D - . . . . . . / . . . . . + . . . . . . . . . . . . . . kW
Multistage centrifugal pump for vertical / angled / horizontal 1) installation. Integrated, anti-blockage check valve with double-guided valve disc. Plain bearing lubricated by the fluid pumped and protected against ingress of sand. Discharge nozzle with threaded end. Submersible canned motor for 1-phase a.c. current (including starter with thermal overcurrent relay) / three-phase current 1), with self--aligning thrust bearing, expansion diaphragm for pressure equalization and cable kit / 1.5 / 2.5 1) m power supply cable. Fluid pumped: clean or slightly contaminated water with a permissible sand content of up to 50 g/m3! CrNi steel glass fibre reinforced NORYL glass fibre reinforced NORYL Chrome steel Rubber CrNi steel m3/h / l/s m oC kW Hz
Outer pump casing, suction casing and check valve housing . . . . . . . . . . . . . . . . . . . . . . . Stage casing (diffuser) . . . . . . . . . . . . . . . . . . . . . Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shaft (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bearing (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor (shaft and housing) . . . . . . . . . . . . . . . . . . Capacity . . . . . . . . . . . . . . . . Head . . . . . . . . . . . . . . . . . . . Temperature (fluid handled) Rated power (motor) . . . . . . Speed / Frequency . . . . . . . Voltage / Starting . . . . . . . . . Pump end . . . . . . . . . . . . . . . Outside diameter . . . . . . . . . Pump set length / weight . . Q = H = t = PN = n U = G Dmax= LA
mm kg
Adapter from G11/4 to R11/2 . to flanged end DN . Adapter from threaded end G Pair of supporting and installation clamps for risers R11/4 (DN 32) / R2 (DN 50)1). Cooling shroud with suction strainer and pedestals for horizontal installation. Power supply cable x mm2, separate/connected 1), length m. Cable connector, separable / non-separable1), with sealing compound, motor supply cable not connected and sealed/connected and sealed1) at the factory. Cable tie UPA CONTROL box for 1 / 230 V and 3 / 400 V with thermal overcurrent relay with phase failure protection, temperature-compensated, insulating enclosure, with 3 electrodes and integrated Dry running protection / Water level control selector switch. Motor contactor for 1 / 230 V with ON/OFF switch for automatic operation, insulating enclosure. Dry running protection equipment: -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of m each. Lightning protection with earthing terminal for 1 230 V / 3 400 V 1). Automatic control unit Controlmatic E / Cervomatic EDP1). Sum total
1)
Delete as applicable
99
Unit p price
Amount
Multistage centrifugal pump for vertical / angled / horizontal 1) installation. Components of stainless steel with a minimum wall thickness of 1 mm and vanes welded at 6 points. Integrated check valve. Generously dimensioned plain bearing lubricated by the fluid pumped. Discharge nozzle with threaded end. Submersible canned motor for 1-phase a.c. current (including starter with thermal overcurrent relay) / three-phase current 1), with self--aligning thrust bearing, expansion diaphragm for pressure equalization and cable kit / 1.5 / 2.5 1) m power supply cable. Fluid handled: clean or slightly contaminated water with a permissible sand content of up to 50 g/m3.
Suction and discharge casing . . . . . . . . . . . . . . . . . . . . CrNi steel Diffusers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel Shaft (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNi steel Bearing (pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rubber Motor (shaft and housing) . . . . . . . . . . . . . . . . . . . . . . . CrNi steel Capacity . . . . . . . . . . . . . . . . . . . . . . . Q = m3/h / Head . . . . . . . . . . . . . . . . . . . . . . . . . . H = m C Temperature (fluid handled) . . . . . . . t = kW Rated power (motor) . . . . . . . . . . . . . PN = Speed / Frequency . . . . . . . . . . . . . . n rpm/ f = V/ direkt Voltage / Starting . . . . . . . . . . . . . . . . U = 11/2 (DN 40) / 2 (DN 50) 1) Pump end . . . . . . . . . . . . . . . . . . . . . . RP Outside diameter . . . . . . . . . . . . . . . . Dmax= mm mm/GA_____kg Pump set length / weight . . . . . . . . . LA Adapter from G Power supply cable to DN x . mm2, separate / connected1), length
l/s
Hz
Pair of supporting and installation clamps for risers R11/4 (DN 32) / R2 (DN 50)1). m Cable connector, separable / non-separable1), with sealing compound,motor supply cable not connected and sealed / connected and sealed1) at the factory. Cable tie UPA CONTROL box for 1~ / 230 V and 3~ / 400 V with thermal overcurrent relay with phase failure protection, temperature-compensated, insulating enclosure, with 3 electrodes and integrated Dry running protection / Water level control selector switch. Motor contactor for 1~ / 230 V with ON / OFF switch for automatic operation, insulating enclosure. Dry running protection equipment: -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of
m each.
Sum total
1)
Delete as applicable
100
Unit p price
Amount
Submersible borehole pump type UPA 150C for well diameters of 150 mm (6 inches) and above. Make: Pump + motor: KSB UPA / +
Multistage centrifugal pump for vertical or horizontal installation in all--stainless steel design S intermediate bearing in every stage S stage casings connected by metal straps S integrated easy--to--remove anti--jam non--return valve S threaded or flanged pump outlet on option S suction strainer, drive lantern and valve body made of investment cast stainless steel S laser--welded impellers S drinking water approved to ACS Pre--filled submersible motor S three--phase current S squirrel--cage design with self--aligning thrust bearing and adequately sized expansion diaphragm for pressure equalisation S design in compliance with VDE standards S IP 68 enclosure S with power supply cable Fluid handled: clean to slightly contaminated water, slightly aggressive / more aggressive / as specified in water analysis1) , with a permissible sand content of up to 50 g/m3. Suction casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump shroud and body of non--return valve . . . . . . . . Impeller, diffuser and stage casing . . . . . . . . . . . . . . . . Shaft (pump + motor) . . . . . . . . . . . . . . . . . . . . . . . . . . . Stator case (motor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bolts, screws and nuts . . . . . . . . . . . . . . . . . . . . . . . . . . Capacity . . . . . . . . . . . . . . . . . . . . . . . Q = Head . . . . . . . . . . . . . . . . . . . . . . . . . . H = Shut-off head . . . . . . . . . . . . . . . . . . . Ho = Temperature (fluid pumped) . . . . . . . t = Rated power / amperage . . . . . . . . . PN = Speed / Frequency . . . . . . . . . . . . . . n Supply voltage . . . . . . . . . . . . . . . . . . U = Starting . . . . . . . . . . . . . . . . . . . . . . . . Outside diameter . . . . . . . . . . . . . . . . Dmax= d.o.l. / 21/
2.....
CrNiMo -- steel CrNiMo -- steel CrNi - / CrNiMo CrNi - / CrNiMo CrNi - / CrNiMo CrNi - / CrNiMo m3/h / m m C kW / IN = rpm / f = V
-----
A Hz
Pair of supporting and installation clamps for riser R / DN 1) Set of bearing pedestals for horizontal installation (for motor UMA only) Power supply cable, separate/connected 1), separable/non--separable1),size . mm2, length
, with sealing compound, Cable connector, motor supply not connected and sealed / connected and sealed 1) at the factory. Cable tie, size UPA CONTROL box for 1~ / 230 V and 3~ / 400 V with thermal overcurrent relay with phase failure protection, temperature-compensated, insulating enclosure, with 3 electrodes and integrated Dry running protection / Water level control selector switch. Dry running protection equipment -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of
m each.
Lightning protection for three-phase current (3~) with earthing terminal. Temperature monitoring equipment Pt 100 for use in submersible motors to protect the windings from overheating; it consists of a resistance thermometer with measuring line and does not include / includes1) a display unit. (for motor UMA only)
Sum total
1)
Delete as applicable
101
Unit p price
Amount
Multistage centrifugal pump in ring-section design for vertical / horizontal 1) installation. Radial or mixed-flow hydraulic systems with impellers that can be turned down. Pump bearing lubricated by the fluid pumped and protected against ingress of sand. Integrated check valve with anti-blockage, spring-loaded valve disc / connection branch. Pump end with internal thread / flange 1). Suction casing with suction strainer fitted between pump and motor. Pre-filled submersible motor. Three-phase current. Squirrel-cage design with self-aligning thrust bearing and adequately sized expansion diaphragm for pressure equalization. Design in compliance with VDE standards. IP 68 enclosure. With power supply cables. Required flow velocity past the motor: v 0.2 m/s. Fluid handled: clean to slightly contaminated water, slightly aggressive / more aggressive / as specified in water analysis1) , with a permissible sand content of up to 50 g/m3.
Casings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cast iron / bronze 1) Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . glass fibre reinforced NORYL/ bronze 1) (UPA 200/200B) / bronze (UPA 250C) Wear rings . . . . . . . . . . . . . . . . . . . . . . . . . . . bronze Shaft (pump + motor) . . . . . . . . . . . . . . . . . . Chrome / CrNiMo steel 1) Stator case (motor) . . . . . . . . . . . . . . . . . . . . CrNi / CrNiMo steel 1) Bolts, screws and nuts . . . . . . . . . . . . . . . . . CrNiMo steel (A4--70) Capacity . . . . . . . . . . . . . . . . . . . . . . . Q = m3/h / l/s Head . . . . . . . . . . . . . . . . . . . . . . . . . . H = m m Shut-off head . . . . . . . . . . . . . . . . . . . Ho = % / Motor % Efficiency . . . . . . . . . . . . . . . . . . . . . . . Pump C Temperature (fluid pumped) . . . . . . . t = kW / IN = A Rated power / amperage . . . . . . . . . PN = rpm / f = Hz Speed / Frequency . . . . . . . . . . . . . . n V Supply voltage . . . . . . . . . . . . . . . . . . U = Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. / star-delta 1) Pump end . . . . . . . . . . . . . . . . . . . . . . G3 (DN 80) / G5 (DN 125) / G6 (DN 150) 1) mm Outside diameter . . . . . . . . . . . . . . . . Dmax= Economic efficiency analysis (for ex. for 10 years): Operating period per year approx. h / Electricity costs /kWh. Pump data tolerances to ISO 9906 Class 1. During the acceptance test, the overall efficiency may be max. 3 percentage points lower than the overall efficiency quoted ( pump x motor). Adapter, from threaded end G to flange DN standard / special 1). . water storage tank. m. with1) Pair of supporting and installation clamps for riser R / DN 1) Set of bearing pedestals for horizontal installation without / Power supply cable, separate/connected 1), mm2, length
Cable connector, size , with sealing compound, motor supply not connected and sealed / connected and sealed 1) at the factory. Cable tie, size . Dry running protection equipment -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of
m each.
Temperature monitoring equipment Pt 100 for use in submersible motors to protect the windings from overheating; it consists of a resistance thermometer with measuring line and does not include / includes1) a display unit. (for motor UMA only)
Sum total
1)
Delete as applicable
102
Unit p price
Amount
Submersible borehole pump(s) type UPA 300/3501) for well diameters of 300 mm (12 inches) and above. Make: Pump + motor: KSB UPA / +
Multistage centrifugal pump in ring-section design for vertical / horizontal 1) installation. Mixed flow hydraulic systems with impellers that can be turned down. Pump bearing lubricated by the fluid pumped and protected against ingress of sand. Integrated check valve with anti-blockage, spring-loaded valve disc / connection branch. Pump end with internal thread / flange 1). Suction casing with suction strainer fitted between pump and motor. Pre-filled submersible motor. Three-phase current. Squirrel-cage design with self-aligning thrust bearing and adequately sized expansion diaphragm for pressure equalization. Design in compliance with VDE standards. IP 68 enclosure. With power supply cables. Required flow velocity past the motor: v 0.2 m/s. Fluid handled: clean to slightly contaminated water, slightly aggressive / more aggressive / as specified in water analysis1) , with a permissible sand content of up to 50 g/m3.
Casings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cast iron / bronze 1) Impellers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bronze Wear rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . bronze Shaft (pump + motor) . . . . . . . . . . . . . . . . . . . . . . . . . . . Chrome / CrNiMo steel 1) Stator case (motor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CrNiMo steel Bolts, screws and nuts . . . . . . . . . . . . . . . . . . . . . . . . . . CrNiMo steel (A4) Capacity . . . . . . . . . . . . . . . . . . . . . . . Q = m3/h / l/s m Head . . . . . . . . . . . . . . . . . . . . . . . . . . H = m Shut-off head . . . . . . . . . . . . . . . . . . . Ho = Efficiency . . . . . . . . . . . . . . . . . . . . . . Pump % / Motor % C Temperature (fluid handled) . . . . . . . t = kW / IN = A Rated power / amperage . . . . . . . . . PN = Speed / Frequency . . . . . . . . . . . . . . n rpm / f = Hz V Supply voltage . . . . . . . . . . . . . . . . . . U = Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . d.o.l. / star-delta 1) Pump end . . . . . . . . . . . . . . . . . . . . . . G6 / G8 / DN 150 / DN 200 / DN 250 1) mm Outside diameter . . . . . . . . . . . . . . . . Dmax= Economic efficiency analysis (for ex. for 10 years): Operating period per year approx. h / Electricity costs /kWh. Pump data tolerances to ISO 9906 Class 1. During the acceptance test, the overall efficiency may be max. 3 percentage points lower than the overall efficiency quoted ( pump x motor ). Pair of supporting and installation clamps for riser R / DN 1). Set of bearing pedestals for horizontal installation without / Power supply cable, separate / connected 1), with1) mm2, . water storage tank. m length.
Cable connector, size , with sealing compound, motor supply not connected and sealed / connected and sealed 1) at the factory. Cable tie, size . Dry running protection equipment -- for semi-automatic operation with 2 1) -- for fully automatic operation with 3 1) control current lines with a length of
m each.
Temperature monitoring equipment Pt 100 for use in submersible motors to protect the windings from overheating; it consists of a resistance thermometer with measuring line and does not include / includes1) a display relay.
Sum total
1)
Delete as applicable
103
50 Hz Submersible Motors for Well Diameters of 100 mm (4 inches) and above Sizes / Connection
DN 100, UMA 150D, UMA 200D: UMA 250D, UMA 300D NEMA standard KSB standard 940.52 271 160.52 900.52 145 901.51 550.52
Material Variants
DN 100 All components UMA G
Shaft 150D
C3
CrNiMo steel (1.4462) CrNiMo steel (1.4462) CrNiMo steel (1.4462)
200D 250D 300D Housing 150D 200D 250D 300D Stator case 150D 200D 250D 300D Screws, bolts and ) nuts 3) 150D 200D 250D 300D
1) 2) 3)
81--59 23--2
Cast iron ( ) 2) (JL1030) Cast iron (JL1040) 1) CrNi steel (1.4301) CrNi steel (1.4301) CrNi steel (1.4301) CrNiMo steel (A4--70) CrNiMo steel (1.4571)
4) 5)
CrNiMo steel (1.4539) ( ) CrNiMo steel (1.4517) CrNiMo steel (1.4539) CrNiMo steel (1.4462)
814 545 382.51 529 900.51 384 412.52 914.51 550.51 59--6 904.52 381 904.51 553 354 484 160.51 500.51 Example: UMA 250D 940.51 389 932.51 412.51 387 32--2 392 903 59--42 920.51 916.51 59--12 950 500.52
CrNiMo steel (1.4571) ---CrNiMo steel (A4--70) CrNiMo steel (A4--70) ----
DIN mat. code: GG-25 DIN mat. code: GG-20 In contact with fluid handled
only for UMA 150D 22/21 only for UMA 150D > 22/21
Bearings / Lubrication
Two radial plain bearings as well as a thrust bearing to balance the pumps axial thrust. Lubrication by motor fill liquid.
104
50 Hz
Submersible Motors
Submersible Motors DN 100 , UMA 150D to 300D: 1~+ 3~, n 2900 rpm, d.o.l. + Y-
PN IN
M
3~
400 V A 1.1 1.6 2.1 3.0 4.0 5.9 7.8 9.1 13.7 13.2 17.2 20.8 28.6 32.0 39.9 46.8 54.3 63.5 78.1 74.2 88.8 107 126 144 174 162 210 248 301 361 466 558 740 4/4 % 66 67 69 73 73 75 76 77 76 76 77 78 81 81 82 84 85 85 83 86 87 88 88.5 88.5 89 88.8 89.0 90.0 90.0 90.2 88.4 89.2 89.6
cos
d.o.l. mm2
Cu (submerged) Y- mm2 ---------------------------2 x 1.5 2 x 1.5 2 x 1.5 2 x 1.5 2 x 1.5 2 x 1.5 2 x 1.5 2x4 2x4 2x4 2 x 10 2x6 2x6 2 x 10 2 x 10 2 x 16 2 x 16 2 x 25 2 x 25 2 x 35 2 x 50 2 x 70 7 x 95 7 x 95
L Standard 3~ mm 223 242 271 299 327 356 423 552 704 699 719 749 829 874 919 1009 1114 1214 1294 1140 1230 1340 1470 1560 1740 1419 1529 1659 1769 1919 2073 2253 2373
3) Parallel cable
m Standard
1~
Motor size DN 100 ... 0.37 0.55 0.75 1.1 1.5 2.2 3.0 3.7 5.5 UMA 150D ... UMA 150D 5/21 UMA 150D 7/21 UMA 150D 9/21 UMA 150D 13/21 UMA 150D 15/21 UMA 150D 18/21 UMA 150D 22/21 UMA 150D 26/21 UMA 150D 30/21 UMA 150D 37/22 UMA 200D ... UMA 200D 37/21 UMA 200D 45/21 UMA 200D 55/21 UMA 200D 65/21 UMA 200D 75/21 UMA 200D 90/21 UMA 250D ... UMA 250D 85/21 UMA 250D 110/21 UMA 250D 132/21 UMA 250D 160/21 UMA 250D 190/21 UMA 300D ... UMA 300D 250/22 UMA 300D 300/22 UMA 300D 400/22
1)
kW 0.37 0.55 0.75 1.10 1.50 2.20 3.00 3.70 5.50 5.5 7.5 9.3 13.0 15.0 18.5 22.0 26.0 30.0 37.0 37 45 55 65 75 90 85 110 132 160 190 250 300 400
2)
380 V A 1.1 1.6 2.1 3.0 3.9 5.8 7.5 9.0 13.5 13.9 18.1 21.8 30.1 33.7 42.0 49.3 57.1 66.8 82.2 78.1 93.5 113 133 152 183
1) 1) 1) 1) 1)
4/4 -0.70 0.75 0.75 0.76 0.76 0.75 0.75 0.79 0.79 0.80 0.82 0.83 0.82 0.83 0.82 0.81 0.82 0.81 0.83 0.84 0.85 0.85 0.85 0.85 0.84 0.85 0.85 0.86 0.86 0.84 0.88 0.87 0.87
1~
kg 8.3 9.6 10.8 13.5 14.4 18.0 ----------------------------------------------------------------------------------
3~
1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 1.5 1 x 4.0 1 x 4.0 1 x 4.0 1 x 4.0 1 x 6.0 1 x 6.0 2 x 4.0 2) 2 x 10 2) 2 x 6 2) 2 x 6 2) 2 x 10 2) 2 x 10 2) 2 x 16 2) 2 x 16 2 x 25 2) 2 x 25 2) 2 x 25 3) 2 x 35 3) 2 x 70 3) 7 x 95 3) 7 x 95 3)
7.3 8.3 9.6 10.8 12.1 13.5 16.0 22.5 29.0 48 50 53 58 62 67 76 87 97 101 130 145 165 187 203 235 260 295 340 390 428 574 652 704
96
143
232
----------
282
On request.
-wiring of the 2 motor leads for d.o.l. starting in the cable connector or in the control box.
Motor cable: DN 100: L = 1.5 m ( 1.5 kW) / 2.5 m (> 1.5 kW), 1 x UMA 150D: L = 4 m, 1 x or 1 x +1x UMA 200D: L = 6 m, 1 x +1x UMA 250D: L = 6 m, 1 x +1x or 1x +1x ( 35 mm2) UMA 300D: L = 10m, 2 x (70 mm2) + 1 x (35 mm2) or (95 mm2) + 1 x (95 mm2) 6x Other cables on request.
105
50 Hz Accessories
Description Electric extension cable1), blue, rubber-sheathed cable for submerged operation in drinking water applications, ambient temperatures t +50 oC. Cable kit, 4-core, round, only for pump sets with three-phase current (3~) motors, DN 100, G RD GWT - J - 4G 1.5 (4 x 1.5 mm2) with earth conductor L = Consisting of: 1 plug, 2.5 m cable, 1 cable connector size 28 and additional cable lengths.
Accessories
Ident. No.
kg
Cable
5m 10 m 15 m 20 m 25 m 30 m 35 m 40 m per m
90 068 166 90 068 167 90 068 168 90 068 169 90 068 170 90 068 171 90 068 172 90 068 173 90 068 174 90 068 175 90 068 176 90 068 177 90 068 178 90 068 179 90 068 180 90 068 181 90 068 182 90 068 183 90 068 148 90 068 149 90 068 150 90 068 151 90 068 152 90 068 153 90 068 154 90 068 155 90 068 156 90 068 157
1.55 2.45 3.35 4.25 5.15 6.05 6.95 7.85 0.180 0.259 0.356 0.475 0.837 1.220 1.770 2.304 3.185 4.364 0.110 0.171 0.252 0.319 0.486 0.750 1.107 1.438 2.054 2.760
4G 1.5 (4 x 1.5 mm2) 4G 2.5 (4 x 2.5 mm2) 4G 4.0 (4 x 4.0 mm2) 4G 6.0 (4 x 6.0 mm2) 4G 10 (4 x 10 mm2) 4G 16 (4 x 16 mm2) 4G 25 (4 x 25 mm2) 4G 35 (4 x 35 mm2) 4G 50 (4 x 50 mm2) 4G 70 (4 x 70 mm2) 3 x 1.5 mm2 3 x 2.5 mm2 3 x 4.0 mm2 3 x 6.0 mm2 3 x 10 mm2 3 x 16 mm2 3 x 25 mm2 3 x 35 mm2 3 x 50 mm2 3 x 70 mm2
per m
For selection see details and examples on pages 110 -- 113 Shielded Hydrofirm (T) cable Shielded Hydrofirm (T) cable Shielded Hydrofirm (T) cable S07BC4B--F S07BC4B--F S07BC4B--F 3x6/6KON 3x16/16KON 3x35+3G16/3 01 101 358 01 101 360 01 101 361 40 980 058 40 980 708 39 020 537 39 020 536 0.1 0.1 0.1 0.1
Standard cable connector with heat shrink tube, non-separable. -- 4 x 1.5 mm2 and 4 x 2.5 mm2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- As above, but connected and sealed at the factory . . . . . . . . . . . . . . . . . . . -- 4 x 4 mm2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- As above, but connected and sealed at the factory . . . . . . . . . . . . . . . . . . . Cable connector, separable, including sealing compound, size 25, only for pump sets with 3~ motors, DN 100, for connecting 1 extension cable to ... 1 motor lead . . . . . . . . . . . . . . . . -- not including connection . . . . . . . . . . . . . . -- including connection . . . . . . . . . . . . . . . . . Note: Can only be supplied together with the pump set. Separately available: - Short cable: - Cable joint:
1)
0.6 0.6
1.5 m long, 4 x 1.5 mm2, with plug and cable joint 2.5 m long, 4 x 1.5 mm2, with plug and cable joint for 1 x 4 x 1.5 mm2, flat, or up to 1 x 4 x 4 mm2, round
106
50 Hz Accessories
Description Cable connector, non-separable, including sealing compound, for connecting 1 extension cable to 1 or 2 motor leads - . Size 28 for connecting 1 extension cable to ... 1 motor lead . . . . . . . . . . . . . -- supplied, but not connected -- connected and sealed at the factory - . Size 35 for connecting 1 extension cable to ... 1 motor lead . . . . . . . . . . . . . -- supplied, but not connected -- connected and sealed at the factory 3300:236/2
Accessories
Ident. No.
kg
95 005 106 0.45 90 049 385 0.45 90 049 397 0.5 90 049 387 0.5 90 049 399 90 049 389 90 049 400 90 049 390 0.55 0.55 0.55 0.55
Size 43 for connecting 1 extension cable to ... a) 1 motor lead -- supplied, but not connected -- connected and sealed at the factory b) 2 motor lead . . . . . . . . . . -- supplied, but not connected -- connected and sealed at the factory
Sizes 53 to 78 available on request. For selection see details and examples on page 114. Cable tie for fastening power supply cable to riser - Size 1 (rubber strap / plastic studs), for cable sizes up to 1 FL 3 x 6 mm2 or 4 x 6 mm2 and 1 RD 4 x 6 mm2 - Sizes 2 - 11 (metal strap / screw band with tension screw / rubber cable protector), for larger cross-sections up to 70 mm2 available on request
Size 1 Size 2
0.04 ------
Note: Cable ties for pump sets of material execution G and B on request. Note: Use 1 cable tie each per cable and per 3 m of riser pipe. For selection see details and examples on page 115. UPA CONTROL box for 1~ / 230 V and 3~ / 400 V, for d.o.l. starting, temperature-compensated, insulating enclosure, with 4 PG cable glands for round cable, 3 immersion electrodes and integrated selector switch for Dry running protection or Water level control operation, as well as with thermal overcurrent relay with phase failure protection, for motor sizes ... 1~/230 V: ---------------0.37 + 0.55 kW 0.75 kW 1.10 kW 1.50 kW 2.2 kW ---------------3~/400 V: 0.37 kW 0.55 kW + 0.75 kW 1.10 kW + 1.50 kW -----2.20 kW 3.00 kW + 3.7 kW 5.50 kW 7.50 kW UMA 150D - 5/21 UMA 150D - 7/21 40 980 887 40 980 889 40 980 891 40 980 893 40 980 895 40 980 897 40 980 899 40 984 811 90 052 649 40 984 811 90 052 649 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Plus 1 control current line, blue, 1 x 1.5 mm2, for each electrode per m Automatic control units Cervomatic EDP with G 11/4 connection, for a max. capacity of 12 m3/h, max. flow rate of Cervomatic EDP 12 m3/h, a max. operating pressure of 10 bar and a max. current rating of 10 A, for 1~ + 3~/ 220 to 240 V and 3~/ 380 to 415 V (with electric protection from 0 to 10 A, can be set in 0.5 A steps). Controlmatic E with G 11/4 connection, for a max. flow rate of 10 m3/h, a max. operating pressure of 10 bar and a max. current rating of 10 A, for 1~ 220 to 240 V
Controlmatic E
107
50 Hz Accessories
Description Dry running protection equipment for ... - semi-automatic operation (1 relay, 1 pushbutton + 2 electrodes) . . . . . . - fully automatic operation (1 relay + 3 electrodes) . . . . . . . . . . . . . . . . . . . . Plus 1 control current line, blue, 1 x 1.5 mm2, for each electrode per m Pressure controller, (membrane-type), insulating enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 -- 10 bar, with R 3/8 connection.
GR H
Accessories
kg
2.0 2.0
Adapter from threaded end G 11/4 to threaded end G 11/2 . . . . . . . . . . Material: CrNiMo steel Mode of supply: sealed and screwed tightly into the pump end.
90 052 823
0.50
GP
D DN H
GP
Adapter, threaded end G / Flange DN, PN 10/40 with 2 recesses on flange, 90o spacing -- G 11/2 / DN 40, CrNi steel (H = 120 mm, D = 155 mm) -- G 2 / DN 50, CrNi steel (H = 145 mm, D = 165 mm) -- G 2 / DN 50, CrNiMo steel (H = 145 mm, D = 165 mm) -- G 3 / DN 80, CrNiMo steel (H = 180 mm, D = 200 mm) Mode of supply: sealed and screwed tightly into the pump end. Other sizes and materials on request. Flanged end piece for UPA 150C only -- Flanged Adapter DN 50, PN 16 DN 65, PN 16 DN 80, PN 16 -- Threated Adapter
3409:3
-- 40 -- 40 -- 40 G3 G4 Pair of supporting and installation clamps for the following riser sizes ... incl. screws, bolts and nuts, -- R 11/4 / DN 32, L = 600 mm, F = 11.8 kN for installation / dismantling -- R 2 / DN 50, L = 600 mm, F = 17.5 kN ofvertical submersible --R 2 1/2 / DN 65 L = 600 mm, F = 17.5 kN pump sets in / -- R 3 / DN 80, L = 600 mm, F = 17.5 kN from wells, tanks, etc. -- R 4 / DN 100 L = 700 mm, F = 24.5 kN Material: Steel, painted. -- R 5 / DN 125 L = 800 mm, F = 31.0 kN -- R 6 / DN 150 L = 800 mm, F = 31.0 kN -- R 8 / DN 200 L = 900 mm, F = 108 kN Note: 2 pairs are required for installation / dismantling. Other sizes and materials on request.
01 116 438 01 116 439 01 116 440 01 124 645 01 124 644 95 000 290 95 000 294 95 000 296 95 000 298 95 000 300 95 000 302 95 000 304 95 000 307
3.28 3.64 7.00 2.50 3.00 7.5 11.5 12.0 12.0 21.0 29.0 29.0 70.0
108
50 Hz Accessories
Description Set of bearing pedestals for horizontal installation consisting of 2 bearing pedestals, incl. screws, bolts and nuts. Material: CrNi steel 1.4301 -- UPA 150C pumps with UMA 150D motors . Galvanized steel -- UPA 200 pumps with UMA 150D motors . . S235 JRG2+Z -- UPA 200 pumps with UMA 200D motors . . CrNi steel 1.4301 -- UPA 200B pumps with UMA 150D motors . -- UPA 200B pumps with UMA 200D motors . -- UPA 250C pumps with UMA 150D motors . -- UPA 250C pumps with UMA 200D motors . -- UPA 250C pumps with UMA 250D motors . Galvanized steel -- UPA 300--65 pumps with UMA 200D motors S235 JRG2+Z -- UPA 300--94 pumps with UMA 200D motors -- UPA 350 pumps with UMA 200D motors . . -- UPA 300--65 pumps with UMA 250D motors -- UPA 300--94 pumps with UMA 250D motors -- UPA 350 pumps with UMA 250D motors . . Note: Screws, bolts and nuts for fixing the bearing pedestals on the foundation are to be supplied by the customer / end user. Other sizes and materials on request. Pt 100 temperature monitoring equipment for use in submersible motors to protect the windings from overheating. Consisting of -- Resistance thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- Control current line, blue, round 4 x 0.5 mm2 . . . . . . . . . . . . . . . . . per m -- Display / control box (supply voltage U = 110/220V) . . . . . . . . . . . . . . . . . Note: Motor with Pt 100 are manufactured to order. Centralizer for submersible motors for UMA 150D and UMA 200D motors in wells up to DN 350, plastic (PE) bis DN 250 bis DN 300 bis DN 350 Other sizes and materials on request. Cooling, suction and pressure shroud for vertical and horizontal installation, Galvanized steel and CrNiMo steel material variants on request.
Accessories
Ident. No.
kg
01 117 821 90 017 255 01 046 640 01 061 866 01 061 867 01 061 868 01 061 869 01 061 870 01 046 644 01 046 645 01 046 646 01 053 905 01 053 906 01 053 907
1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 7.8 7.8 8.0 16.0 16.0 17.2
----------------
Stainless steel immersion electrodes Stainless steel wire rope for S 100D
3 electrodes 1 electrode 15 m 30 m
40 980 055 40 980 056 42 200 727 42 204 021 00 533 291 00 533 299 40 980 709
Lightning protection with earthing terminal for -- 1~/ 230 V (fitted in soft starter of DN 100 motor) . . . . . . . . . . . . . . . . . . . . . -- 3~/ 400 V (supplied separately) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cable tie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . per unit
109
Accessories
For use in water as submersible motor lead (3- + 4-core, flat) and for use in air as extension cable from motor lead to control box / mains (3-core, flat and 4-core, round).
Application Limits
Rated voltage: -- UN 1000 V for ex. in wells, -- UN 750 V in swimming pools. Ambient temperature . . . . . t +50 oC. Immersion depth . . . . . . . . . 500 m.
Description / Design
a) Flat cables:
1)
b) Round cables:
2)
3 cores
1) 2)
4 cores
1 core
4 cores
As a standard, for use as motor lead only. For use as earth conductor only.
3-/4-core rubber-sheathed cable. Consisting of finely stranded bare copper conductors, core insulation and outer sheath made of special rubber compound on EPR basis (ethylene propylene rubber), blue. With BAM 1) certificate, i.e. suitable for permanent use in drinking water applications.
1)
Designation (Example)
Flat cable: ZN 1391 - G Factory standard Insulation: rubber FL: flat + RD: round For drinking water Earth conductor: O = without, - J = with Cores (O: 3 x 25, J: 4 G 25) Materials FL GWT -J 4G25 - Cu-Rubber
Dimensions + Weights
Cross-section Type 1.5 2.5 6.1 + 1.5 13.2 + 2.3 0.171 6.1 + 1.5 17.5 + 2.5 0.237 ----------12.0 + 1.9 0.259 4 7.0 + 2 15.5 + 3.5 0.252 7.0 + 2 21.0 + 2.5 0.339 ----------13.9 + 2 0.356 6 7.6 + 2.2 17.4 + 3.6 0.319 7.6 + 2.2 23.5 + 3 0.440 ----------15.7 + 2.1 0.475 10 9.3 + 2.2 21.5 + 3.5 0.486 9.3 + 2.2 29.0 + 3.5 0.704 ----------21.1 + 2.1 0.837 q in mm2 16 11.2 + 2.3 26.7 + 4.3 0.750 11.2 + 2.3 35.0 + 2.4 1.026 ----------24.5 + 4.3 1.220 25 13.0 + 2.5 31.6 + 3.9 1.107 13.0 + 2.5 41.5 + 4.5 1.457 ----------29.7 + 4.3 1.770 35 14.6 + 2.9 35.5 + 5 1.438 ---------------13.8 + 3.6 0.499 33.3 + 5.5 2.304 50 17.0 + 3 42.1 + 4.9 2.054 ---------------16 + 3.8 0.699 39.0 + 5.6 3.185 70 19.3 + 2.7 48.4 + 3.6 2.760 ---------------------
mm
5.2 + 1 11.0 + 2 0.110 5.2 + 1 14.5 + 2.7 0.165 5.3 + 1.1 0.051 10.0 + 2 0.180
$ mm m kg/m
mm
$ mm m kg/m
mm
m kg/m
mm
m kg/m
110
Accessories
1) For 2 cables II: I 2 x I N max. 2) I max for submerged use, laid in free water or 3) I max for use in open air, laid along a surface.
closely along the pump. For other conditions see DIN VDE 0298. For other conditions see DIN VDE 0298.
b) Ambient temperature t > + 30 oC! If t > + 30 oC, the current-carrying capacity of the cables is lower. Imax indicated under a) must be de-rated by a factor fT: t in C 35 fT [ ---- ] 0.96 40 0.91 45 0.87 50 0.82
-- 2 cables in parallel (II): 3 ... U = 1.55 x L x IN x cos phi q x U [%] 1 ... U = 1.8 x L x IN x cos phi q x U [%]
= single cable length [m] = rated current [A] = power factor at 4/4 load = copper conductor cross-section [mm2] = supply voltage [V]
111
Accessories
400 300
Imax = 250 A Imax = 202 A Imax = 162 A Imax = 131 A Imax = 99 A Imax = 74 A
200
100 90 80 70 60 50 40 30
Imax = 53 A Imax = 41 A
2.5 mm2
20
IN
[A]
10 9 8 7 6 5 4 3
1 10 20 30 40 50 60 70 80 90100
L [m]
200
300
400
500
Example: a) IN = 68 A, 1 x 16 mm2 , U 3 % L 105 m! IN = motor current resulting from actual voltage b) IN = 68 A, 1 x 25 mm2 , U 3 % L 165 m!
For supply voltages other than 400 V, the cable lengths must be calculated as follows, for ex. ... U1 = 400 V, L1 = 105 m, U2 = 500 V L2 = (U2 : U1) x L1, L2 = (500 V : 400 V) x 105 m = 131.3 m! For parallel cables the value is doubled to obtain the permissible length. 112
Accessories
400 300
200
10 mm2
100 90 80 70 60 50 40 30
Imax = 92 A Imax = 71 A
2.5 mm2
20
IN
[A]
10 9 8 7 6 5 4 3
1 10 20 30 40 50 60 70 80 90100
L [m]
200
300
400
500
Example: a) IN = 27 A, 2 x 6 mm2, U 3 % L 145 m! IN = motor current resulting from actual voltage U1 = 400 V, L1 = 145 m, U2 = 500 V, b) IN = 27 A, 2 x 10 mm2 , U 3 % L 235 m!
For supply voltages other than 400 V, the cable lengths must be calculated as follows, for ex. ... L2 = (U2 : U1) x L1, L2 = (500 V : 400 V) x 145 m = 181.3 m! 113
Accessories
Used to provide a sealed, water--tight connection between electric extension cable and submersible motor lead. Supply voltage . . . . . . . . . . . U 750 V. Ambient temperature . . . . . t +50 oC. Immersion depth . . . . . . . . . 500 m.
Applications
Type, number and dimensions of the motor lead and the extension cable. The table below only shows the electric cables on stock. Connectors for other cables on request.
Extension cable ... mm2 1.5 2.5 4 6 10 16 25 35 50 70 Cable connector size ...
1.5 / 2.5 4 6 10 16 25 35 50 70
28 -------------------------
28 35 ----------------------
28 35 35 -------------------
35 35 35 43 ----------------
35 35 35 43/29 f ----------------
------------66 66 66 66 ----
------------66 66 66 66 66
1.5 / 2.5 4 6 10 16 25
+ + or
28 ----------------
28 35 -------------
28 35 35 ----------
35 35 35 43 -------
35 35 35 43 -------
43 43 43 43 53 ---1)
53 53 53 53 53 66
53 53 53 53 53 66
------------66 66
------------66 66
1.5 2.5 4 6 10 16 25
28 35 ----------------
28 35 ----------------
28 35 35 -------------
35 35 35 43 66 -------
35 35 35 43 66 -------
------43 43 66 66 ---1)
---------53 66 66 78
---------53 66 66 78
---------66 66 66 78
---------66 66 66 ----
1.5 / 2.5 / 4 6 10 16 25 35 50 70
2)
28 28 ----------------------------
28 28 ---------------------------2)
28 28 35 -------------------------
28 28 35 -------------------------
35 35 35 43 ----------------------
43 43 43 43 53 ---------2)
---53 53 53 53 -------------------
---------66 78 78 78 78 ------35
35 50 70
1)
----------
Legend: 114
Accessories
Selection Criteria
Type, number and size of the electric cable, as well as nominal diameter and length of the riser / discharge pipe.
Selection Table
Electric cable Type Flat Number x core dia. in mm2 3 x 1.5 to 3 x 6.0 3 x 10 to 3 x 70 Round 3 x 1.5 to 3 x 6.0 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 3 x 95 4 x 1.5 to 4 x 6.0 4 x 10 to 4 x 70 4 x 1.5 to 4 x 6.0 4 x 10 4 x 16 4 x 25 4 x 35 4 x 50 4 x 70 4 x 95 Tie size ---1 m 1)
kg
Required length of strap L per cable tie in ... mm for risers G .../DN ... 1 1/4/ 32 270 1 1/2/ 40 280 2/ 50 320 .../ 65 360 3/ 80 400 4/ 100 450 5/ 125 500 6/ 150 600 .../ 175 -------8/ 200 -------250 -------300 -------350 -------400 --------
----
11
0.01
----
----
350
400
450
550
650
800
950
1100
1300
1500
1700
1900
----
270
280
320
360
400
450
500
600
------
------
------
------
------
------
2 3a 3 3b 4 7 8 6 9
--------------------------------------------
--------------------------------------------
Design
Size 1: Size 11:
d b c e a
Sizes 6, 7, 8, 9:
b a d c
a= b= c= d=
Note: -- Use 1 cable tie each per cable and per 3 m of riser pipe. -- If an extension cable with a larger diameter is connected to the motor lead, the cable tie size required for the larger cable is to be used along the entire cable length.
115
Depending on the general installation arrangement (i.e. depending, for example, on the ratio of outside motor diameter to inside well or shroud diameter, etc.) a distinction must be made between the following cases ... a) v = 0 m/s ... this applies, for example, when the pump set is installed in a deep well below the well screen / filter, in a pump sump, tank or other reservoir, etc. Caution: At v = 0 m/s, UMA 250D motors can only be operated at reduced rated power. b) v 0.2 m/s ... this describes with adequate accuracy the case when the pump set is, for example, installed in a deep well above the well screen / filter, etc. In borderline cases (for ex. if the inside well diameter is very large compared with the outside motor diameter) the diagram below can be used to double-check the data. c) v 0.5 m/s ... In this case it must always be checked, using the diagram below, whether the installation dimensions (i.e. the ratio of outside motor diameter to inside well diameter) are adequate to ensure a minimum flow velocity past the motor of v 0.5 m/s. If not, use a special cooling shroud. How to read the diagram: The requirement for a flow velocity past the motor of v 0.2 or 0.5 m/s is met, if the point of intersection of the capacity Q and the inside well or shroud diameter DN is located on or to the right of the curve applicable to the submersible motor used.
Max. permissible well diameter for compliance with required flow velocity past the motor
1400
V >= 0.2 m/s
1200 [mm]
1000
V >= 0.5 m/s
800 600 400 200 0 0 100 200 300 400 500 600 700 800 900
DN 100V > 0.1
Q [m#/h]
Example: Given: UPA 300 - 65/4 + UMA 250D 160/21 and v 0.2 m/s. Found: For Q = 250 m3/h ( Qopt) the following applies: DN 700 mm. This means that the requirement for v 0.2 m/s is met, if the pump set is, for example, installed in a well or cooling shroud of DN 700 mm or 28 inches.
116
50 Hz
117
3400.5/6 -- 10 07/2008