You are on page 1of 10

R

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

Weiber's Multi-Function Process Calibrator is unique and ideal equipment for research and general applications in the field of measurement and analysis of electricity (electric current) in terms of - voltage current (DC); electrical resistance, frequency, thermocouple, thermo resistance, Switch meter measure, and continuity test.

Major Technical Features


Large LCD display of screen Portable and hand-held equipment Easy to operate White LED for backlight

Application

Kitchen appliances Washing and drying machines Electrical systems Electronics used in automobile

TECHNOCRACY PVT. LTD.

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

Technical Features
Range Resolving Power Remark Measuring Range Accuracy Range Resolving Power Remark Measuring Range Accuracy Range Resolving Power Remark Measuring Range Accuracy Range Resolving Power Remark Measuring Range Accuracy 50 mV 1V Input Impedance : about 100 M 5.000 mV - 55.000 mV 0.02 % + 10 500mV 10V Input Impedance:about 100 M 10.00mV - 550.00mV 0.02%+2 5V 0.1mV Input Impedance : about 1 M O 0.1000V - 5.5000V 0.02%+5 50 V 10mV Input Impedance : about 1 M O 0.00V - 55.00V 0.03 % + 5

TECHNOCRACY PVT. LTD.

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

DC Current

Range Resolving Power Remark Measuring Range Accuracy

50 mA 1A Input Impedance 10 5.000mA - 55.000mA 0.02%+2

OHM
Range Resolving Power Remark Measuring Range Accuracy Range Resolving Power Remark Measuring Range 500 About 1 mA exciting 0.01 Plough voltage : about 2.5V not including the accuracy of down-lead resistance 0.00- 550.00 0.02% + 0.1 5 K About 0.1 mA exciting 0.1 Plough voltage about 2.5V not including the accuracy of down-lead resistance 0.0000 K; - 5.5000K 0.02%+0.5

TECHNOCRACY PVT. LTD.

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

Frequency
Range Resolving Power Remark Measuring Range Accuracy Range Resolving Power Remark Measuring Range 100Hz 0.1Hz input impedance: 100 k; or more Square wave at least 1Vpp 50% duty cycle 2Hz - 110.0Hz +/-2 1KHz 1Hz Input Impedance : 100 k or more Square wave at least 1Vp-p 50% duty cycle 0.100KHz1.100KHz Accuracy Range Resolving Power Remark Measuring Range 2 10KHz 0. 1KHz Input Impedance : 100 k; or more Square wave at least 1Vp-p 50% duty cycle 10KHz11.0KHz

TECHNOCRACY PVT. LTD.

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

Thermocouple
Range : Measuring Range Resolving Power Accuracy Remark Range : Measuring Range : Resolving Power : Accuracy : Remark : Range : Measuring Range : Resolving Power : Accuracy : Remark : Range : Measuring Range : Resolving Power : Accuracy : Remark : Range : Measuring Range : Resolving Power : Accuracy :
TECHNOCRACY PVT. LTD.

R -40C -1760 C(o) 1 C(o) -4500 : 1.8 &n- 501760 : 1.5 Adopt ITS-90 thermometric scale not including the accuracy of inner temperature compensatory error S - 20C ----- 1760C 1 C 4500 : 1.8 - 501760 : 1.5 dopt ITS-90 thermometric scale not including the accuracy of inner temperature compensatory error K - 200C ---- 950C 0.1C - 2000 : 1.2 ----- 01370 : 0.8 Adopt ITS-90 thermometric scale not including the accuracy of inner temperature compensatory error E -200C ------ 500 C 0.1C -2000 : 0.9 01000 : 1.5 Adopt ITS-90 thermometric scale not including the accuracy of inner temperature compensatory error J - 200C ----- 700C 0.1C -2000 : 1.0 ---- 01200 : 0.7

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

Remark : Range : Measuring Range : Resolving Power : Accuracy : Remark :

Range : Measuring Range : Resolving Power : Accuracy : Remark : Range : Measuring Range : Resolving Power : Accuracy : Remark : Range : Measuring Range : Resolving Power : Accuracy : Remark : Range :

Adopt ITS-90 thermometric scale not including temperature compensatory error T -200C - 400C 1 C -2000 : 1.0 ----- 0400 : 0.7 Adopt ITS-90 thermometric scale not including temperature compensatory error N -200C ----- 1000C 0.1C -2000 : 1.5 ---- 01300 : 0.9 Adopt ITS-90 thermometric scale not including temperature compensatory error B 400C ---- 1800C 1C 400800 : 2.2 8001000 : 1.8 10001800 : 1.4 Adopt ITS-90 thermometric scale not including temperature compensatory error PT 100 - 200C ---- 700C 0.1C - 2000 : 0.5 0400 : 0.7 400850 : 0.8 Adopt ITS-90 thermometric scale not including temperature compensatory error PT 1000

the accuracy of inner

the accuracy of inner

the accuracy of inner

the accuracy of inner

the accuracy of inner

TECHNOCRACY PVT. LTD.

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

TECHNOCRACY PVT. LTD.

MULTI FUNCTION PROCESS CALIBRATOR


MODEL NO.- ACM-MFPC

Measuring Range : Resolving Power : Accuracy : Remark :

- 200C ----- 630C 0.1C - 200100 : 0.22 100300 : 0.3 300630 : 0.4 Adopt ITS-90 thermometric scale not including the accuracy of inner temperature compensatory error

Switch Meter Measure


Range Measuring Range 1 mA (approx.) exciting CLOSE / OPEN

Continuity Test
Range Resolving Power Measuring Range 500 About 1 mA exciting 0.01 50 vocalism

TECHNOCRACY PVT. LTD.

An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products

www.acmasindia.com | www.cleanroom-equipments.com | www.measuring-meters.com

TECHNOCRACY PVT. LTD.


SALES OFFICE (INDIA)
Office no. 506 & 507, 5th Floor, Plot no.- C-9, Pearls Best Height-II, Netaji Subhash Place, Pitam Pura, Delhi- 110034 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com

SALES OFFICE (HONG KONG)


Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 0086- 18922303099 E-mail.: hk@acmasindia.com

SHOWROOM
J-284 Sector 1 Bawana Industrial Estate, Bawana, Delhi, INDIA-110039 Tel.: 0091-0-9312219738 (M) +91- 9717741167 E-mail.: info@acmasindia.com

SALES OFFICE (RUSSIA)


Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com

You might also like