You are on page 1of 1

186262327.xls.

ms_office

Axially loaded steel column design to EC3


Based on ESDEP example 7.5(i) Level Length K-factor Loads Dead Self Live Reduction Factored (top) 1 3.5 0.8 Roof 192 2 72 0 369.90 2 4.3 0.8 3rd floor 312 2 144 10 977.40 3 4.3 0.8 2nd floor 312 3 144 20 1543.05 4 6 1 1st floor 312 4 144 30 2066.85 Note: Effective length factor K from ESDEP lecture7.7 table 1

Trial calculations Level Steel Grade S Trial pc Required Area 4 LE= 6 m 275 Load 2066.85 kN 186 N/mm 111.1 cm Try col. No. 10

Output
Serial size 254x254mm x89 kg/m U C permissible stess (pc) 214 N/mm Load Capacity 2435 kN Capacity / Load 1.18 Detailed Calculations axis Radius of gyration slenderness ratio scr Euler stress Reference slenderness Imperfection a f Reduction factor c Compressive strength

Ok

z-z 11.21 53.52 706.3 0.62 0.033 0.7018 0.978 269

y-y 6.52 92.02 238.9 1.07 0.340 1.0901 0.779 214

py E Area tw

275 205000 113.63 10.5

N/mm N/mm cm mm

ESDEP Lecture 7.5.1 section 5.1 ESDEP Lecture 7.5.1 section 5.2

N/mm

Page 1