You are on page 1of 395

ZXWM M900

Dense Wavelength Division Multiplexing Optical Transmission System

Hardware Manual
Version 2.20

ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 800-9830-9830 Fax: (86) 755 26772236 URL: http://support.zte.com.cn E-mail: doc@zte.com.cn

LEGAL INFORMATION Copyright 2007 ZTE CORPORATION. The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations. All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION or of their respective owners. This document is provided as is, and all express, implied, or statutory warranties, representations or conditions are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein. ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter herein. ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice. Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information. The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History Date 31/07/2005 Version No. V1.0 Revision No. R1.1 Serial No. sjzl20040738 Description The first publication for ZXWM M900 (V1.0). This manual is issued due to the upgrade of ZXWM M900 from V2.0 to V2.20. The modifications of new version equipment include: 24/09/2007 V2.0 R1.1 sjzl20051582 The installation in 600 mm cabinet is provided. Centralized wavelength supervision subsystem optical power automatic equalization, function of wavelength tuneable, and 100M supervision system are provided. The technical specifications are updated, including board consumption and the specifications of system elements.

This manual is issued due to the upgrade of ZXWM M900 from V2.0 to V2.1. The modifications of new version equipment include:

30/10/2007

V2.1

R1.0

sjzl20073165

OTUE10G, VGSC, DGE and SWE boards are not provided any longer. New boards EOA and DSAF are available now. The function of OTU10G, OTUF, OMU, ODU, OBM, OCI, VMUX, OWM and LAC boards are updated.

Date

Version No.

Revision No.

Serial No.

Description The SC/PC connector of the board is changed into LC/PC connector.

This new version supports C-band DWDM system over G.653 fiber. This manual is revised according to the modifications of the new version equipment. This manual is issued due to the upgrade of ZXWM M900 from V2.1 to V2.20. The modifications of new version equipment include: OA, HOBA and OTUP boards are not provided any longer. New boards MCPD and EOTU10G are available now. 48/96-wavelength system in C band is available now, and the functions of Mux/DeMux board are updated, including OMU, ODU, OCI, VMUX and OBM. ROADM function is available now, the boards include WBU, WSU and WBM. TMUX subrack with the functions of electric cross and electric layer protection are provided. The boards include DSAE, SMU and CSU. Convergence boards are provided, including GEM2, GEM8, DSA and DSAF. Protection boards are provided, including OPCS and OPMS. The function of EOA, OWM and OPM boards are updated. The technical specifications are updated, including board consumption and the specifications of system elements.

05/30/2008

V2.20

R1.0

sjzl20081768

ZTE CORPORATION Values Your Comments & Suggestions!


Your opinion is of great value and will help us improve the quality of our product documentation and offer better services to our customers. Please fax to: (86) 755-26772236; or mail to Publications R&D Department, ZTE CORPORATION, ZTE Plaza, A Wing, Keji Road South, Hi-Tech Industrial Park, Shenzhen, P. R. China 518057. Thank you for your cooperation!
Document Name Product Version

ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System Hardware Manual V2.20
Document Revision Number R1.0

Equipment Installation Date Presentation: (Introductions, Procedures, Illustrations, Completeness, Level of Detail, Organization, Appearance) Good Your evaluation of this documentation Accessibility: (Contents, Index, Headings, Numbering, Glossary) Good Fair Average Poor Bad N/A Fair Average Poor Bad N/A

Intelligibility: (Language, Vocabulary, Readability & Clarity, Technical Accuracy, Content) Good Fair Average Poor Bad N/A Please check the suggestions which you feel can improve this documentation: Your suggestions for improvement of this documentation Improve the overview/introduction Improve the Contents Improve the organization Include more figures Add more examples Add more detail Other suggestions Make it more concise/brief Add more step-by-step procedures/tutorials Add more troubleshooting information Make it less technical Add more/better quick reference aids Improve the index

__________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ # Please feel free to write any comments on an attached sheet.

If you wish to be contacted regarding your comments, please complete the following: Name Postcode Telephone Company Address E-mail

Contents
About this Hardware Manual .......................................................... i Purpose ............................................................................................i Whats in This Manual ....................................................................... ii Related Documentation.................................................................... iii Conventions.................................................................................... iv
Typographical Conventions..................................................................................iv Mouse Operation Conventions.............................................................................iv

Safety Signs.....................................................................................v How to Get in Touch ........................................................................ vi


Customer Support ................................................................................................vi Documentation Support.......................................................................................vi

Chapter 1........................................................................................ 1 Cabinet ........................................................................................... 1 ZTE Cabinet .....................................................................................1


Structure ............................................................................................................... 1 Basic Fittings in Cabinet....................................................................................... 3

Cabinet Configurations for ZXWM M900..............................................6 Chapter 2........................................................................................ 9 Components ................................................................................... 9 OA Subrack......................................................................................9
Board Slots.......................................................................................................... 12 Common Interface Area..................................................................................... 15

OTU Subrack..................................................................................21
Board Slots.......................................................................................................... 23 Common Interface Area..................................................................................... 24

TMUX Subrack................................................................................25
Board Slots.......................................................................................................... 25

Common Interface Area..................................................................................... 27

Orderwire Phone Bracket.................................................................29 Independent Fan Unit .....................................................................29 Power Alarm Subrack......................................................................31
Power Distribution Subrack ............................................................................... 32 Monitoring Plug-in Box....................................................................................... 33

ODF Plug-in Box .............................................................................34 DCM Plug-in Box.............................................................................36 Chapter 3...................................................................................... 39 Boards .......................................................................................... 39 Overview .......................................................................................39 Structure of Boards.........................................................................41
Structure of Boards in OA/OTU/TMUX Subrack ............................................... 41 Structure of PBX Board ...................................................................................... 42 Structure of PWSB Board ................................................................................... 43 Structure of FCB Board....................................................................................... 43

OTU Board .....................................................................................44


Functions ............................................................................................................ 44 Operating Principle............................................................................................. 45 Front Panel: Interfaces and Indicators ............................................................. 47 Performance and Alarm Messages .................................................................... 50

OTUF Board ...................................................................................51


Functions ............................................................................................................ 51 Operating Principle............................................................................................. 53 Front Panel: Interfaces and Indicators ............................................................. 55 Performance and Alarm Messages .................................................................... 57

OTU10G Board ...............................................................................59


Functions ............................................................................................................ 59 Operating Principle............................................................................................. 60 Front Panel: Interfaces and Indicators ............................................................. 62 Performance and Alarm Messages .................................................................... 64

EOTU10G Board .............................................................................65


Functions ............................................................................................................ 65 Operating Principle............................................................................................. 67 Front Panel: Interfaces and Indicators ............................................................. 69 Performance and Alarm Messages .................................................................... 71

SRM41/SRM42 Board......................................................................75

Operating Principle............................................................................................. 76 Front Panel: Interfaces and Indicators ............................................................. 78 Performance and Alarm Messages .................................................................... 81

GEM2 Board...................................................................................86
Functions ............................................................................................................ 86 Operating Principle............................................................................................. 87 Front Panel: Interfaces and Indicators ............................................................. 88 Performance and Alarm Messages .................................................................... 91

GEMF Board...................................................................................94
Functions ............................................................................................................ 94 Operating Principle............................................................................................. 94 Front Panel: Interfaces and Indicators ............................................................. 96 Performance and Alarm Messages .................................................................... 99

GEM8 Board................................................................................. 102


Functions .......................................................................................................... 102 Operating Principle........................................................................................... 102 Front Panel: Interfaces and Indicators ........................................................... 104 Performance and Alarm Messages .................................................................. 106

DSA Board................................................................................... 111


Functions .......................................................................................................... 111 Operating Principle........................................................................................... 112 Front Panel: Interfaces and Indicators ........................................................... 114 Configuration of DSA Board ............................................................................. 116 Performance and Alarm Messages .................................................................. 119

DSAF Board ................................................................................. 123


Functions .......................................................................................................... 123 Operating Principle........................................................................................... 125 Front Panel: Interfaces and Indicators ........................................................... 128 Performance and Alarm Messages .................................................................. 130 Configuration of DSAF Board ........................................................................... 135

DSAE Board ................................................................................. 136


Functions .......................................................................................................... 136 Operating Principle........................................................................................... 137 Front Panel: Interfaces and Indicators ........................................................... 139 Configuration of DSAE Board ........................................................................... 141 Performance and Alarm Messages .................................................................. 143

SMU Board................................................................................... 145


Functions .......................................................................................................... 145

Operating Principle........................................................................................... 147 Front Panel: Interfaces and Indicators ........................................................... 149 Performance and Alarm Messages .................................................................. 150

OCI Board.................................................................................... 154


Functions .......................................................................................................... 154 Operating Principle........................................................................................... 154 Front Panel: Interfaces and Indicators ........................................................... 156 Optical Connections of OCI Board ................................................................... 158 Performance and Alarm Messages .................................................................. 159

OBM Board .................................................................................. 160


Functions .......................................................................................................... 160 Operating Principle........................................................................................... 160 Front Panel: Interfaces and Indicators ........................................................... 161 Optical Connections of OBM Board .................................................................. 164 Performance and Alarm Messages .................................................................. 165

OMU Board .................................................................................. 166


Functions .......................................................................................................... 166 Operating Principle........................................................................................... 166 Front Panel: Interfaces and Indicators ........................................................... 167 Optical Connections of OMU Board.................................................................. 169 Performance and Alarm Messages .................................................................. 170

VMUX Board................................................................................. 171


Functions .......................................................................................................... 171 Operating Principle........................................................................................... 172 Front Panel: Interfaces and Indicators ........................................................... 173 Optical Connections of VMUX Board................................................................ 174 Performance and Alarm Messages .................................................................. 175

ODU Board .................................................................................. 176


Functions .......................................................................................................... 176 Operating Principle........................................................................................... 176 Front Panel: Interfaces and Indicators ........................................................... 177 Optical Connections of ODU Board .................................................................. 179 Performance and Alarm Messages .................................................................. 180

OAD Board................................................................................... 181


Functions .......................................................................................................... 181 Operating Principle........................................................................................... 181 Front Panel: Interfaces and Indicators ........................................................... 182 Optical Connections of OAD Board .................................................................. 184

Performance and Alarm Messages .................................................................. 185

WBU Board .................................................................................. 185


Functions .......................................................................................................... 185 Operating Principle........................................................................................... 185 Front Panel: Interfaces and Indicators ........................................................... 187 Optical Connections of WBU Board.................................................................. 189 Performance and Alarm Messages .................................................................. 191

WSU Board .................................................................................. 191


Functions .......................................................................................................... 191 Operating Principle........................................................................................... 191 Front Panel: Interfaces and Indicators ........................................................... 196 Optical Connections of WSU Board.................................................................. 198 Performance and Alarm Messages .................................................................. 200

WBM Board.................................................................................. 200


Functions .......................................................................................................... 200 Operating Principle........................................................................................... 201 Front Panel: Interfaces and Indicators ........................................................... 202 Optical Connections of WBM Board ................................................................. 203 Performance and Alarm Messages .................................................................. 205

SDM Board .................................................................................. 205


Functions .......................................................................................................... 205 Operating Principle........................................................................................... 206 Front Panel: Interfaces and Indicators ........................................................... 206 Optical Connections of SDM Board .................................................................. 208 Performance and Alarm Messages .................................................................. 209

EOA Board ................................................................................... 209


Function and Operating Principle .................................................................... 209 Operating Principle........................................................................................... 212 Front Panel: Interfaces and Indicators ........................................................... 215 Optical Connections of EOA Board................................................................... 223 Performance and Alarm Messages .................................................................. 224

DRA Board................................................................................... 226


Functions .......................................................................................................... 226 Operating Principle........................................................................................... 227 Front Panel: Interfaces and Indicators ........................................................... 229 Optical Connections of DRA Board................................................................... 231 Performance and Alarm Messages .................................................................. 231

LAC Board.................................................................................... 232

Functions .......................................................................................................... 232 Operating Principle........................................................................................... 232 Front Panel: Interfaces and Indicators ........................................................... 233 Optical Connections of LAC Board ................................................................... 235 Performance and Alarm Messages .................................................................. 236

OWM Board ................................................................................. 236 Functions..................................................................................... 236


Operating Principle........................................................................................... 237 Front Panel: Interfaces and Indicator............................................................. 238 Optical Connections of OWM Board................................................................. 239 Performance and Alarm Messages .................................................................. 240

OPM Board................................................................................... 240


Functions .......................................................................................................... 240 Operating Principle........................................................................................... 241 Front Panel: Interfaces and Indicators ........................................................... 241 Performance and Alarm Messages .................................................................. 243

MCPD Board................................................................................. 244


Board Function ................................................................................................. 244 Operating Principle........................................................................................... 245 Performance and Alarm ................................................................................... 245 Front Panel: Interfaces and Indicators ........................................................... 246

OP Board ..................................................................................... 247


Functions .......................................................................................................... 247 Operating Principle........................................................................................... 248 Front Panel: Interfaces and Indicators ........................................................... 249 Optical Connections of OP Board ..................................................................... 251 Performance and Alarm Messages .................................................................. 255

OPMS Board................................................................................. 255


Functions .......................................................................................................... 255 Operating Principle........................................................................................... 256 Front Panel: Interfaces and Indicators ........................................................... 256 Performance and Alarm Messages .................................................................. 259 Configuration of OPMS Board .......................................................................... 259

OPCS Board ................................................................................. 260


Functions .......................................................................................................... 260 Operating Principle........................................................................................... 260 Front Panel: Interfaces and Indicators ........................................................... 262 Performance and Alarm Messages .................................................................. 264

Configuration of OPCS Board ........................................................................... 264

OMCP Board................................................................................. 265


Functions .......................................................................................................... 265 Operating Principle........................................................................................... 265 Front Panel: Interfaces and Indicators ........................................................... 266 Optical Connections of OMCP Board................................................................ 269 Performance and Alarm Messages .................................................................. 271

NCP Board ................................................................................... 271


Functions and Operating Principle .................................................................. 271 Front Panel: Interface and Indicators............................................................. 272 Performance and Alarm Messages .................................................................. 275

OSC Board................................................................................... 275


Operating Principle........................................................................................... 276 Front Panel: Interfaces and Indicators ........................................................... 276 Optical Connections of OSC Board................................................................... 278 Performance and Alarm Messages .................................................................. 279

OHP Board................................................................................... 280


Functions and Operating Principle .................................................................. 280 Front Panel: Interfaces and Indicators ........................................................... 282 Performance and Alarm Messages .................................................................. 283

NCPF Board.................................................................................. 283


Operating Principle........................................................................................... 283 Front Panel: Interfaces and Indicators ........................................................... 285 Performance and Alarm Messages .................................................................. 286

OSCF Board ................................................................................. 286


Operating Principle........................................................................................... 287 Front Panel: Interfaces and Indicators ........................................................... 287 Configuration of OSCF Board ........................................................................... 291 Performance and Alarm Messages .................................................................. 292

OHPF Board ................................................................................. 293


Operating Principle........................................................................................... 293 Front Panel: Interface and Indicators............................................................. 294 Performance and Alarm Messages .................................................................. 296

APSF Board.................................................................................. 296


Operating Principle........................................................................................... 297 Front Panel: Interfaces and Indicators ........................................................... 297 Performance and Alarm Messages .................................................................. 299

PBX Board ................................................................................... 300

Operating Principle........................................................................................... 300 Front Panel and Rear Panel ............................................................................. 301 Performance and Alarm Messages .................................................................. 302

PWSB Board ................................................................................ 302


Operating Principle........................................................................................... 303 Front Panel: Interfaces and Indicators ........................................................... 304 Performance and Alarm Messages .................................................................. 309

FCB Board ................................................................................... 310


Front Panel........................................................................................................ 310 Performance and Alarm Messages .................................................................. 311

CA Board ..................................................................................... 311


Operating Principle........................................................................................... 312 Front Panel: Interfaces and Indicators ........................................................... 313 Performance and Alarm Messages .................................................................. 316

CSU Board ................................................................................... 316


Functions .......................................................................................................... 316 Operating Principle........................................................................................... 317 Front Panel........................................................................................................ 319 Performance and Alarm Messages .................................................................. 321

Appendix A ................................................................................. 323 Optical Connections of ZXWM M900.......................................... 323 8/16/32/40/48-Channel System .................................................... 323 80/96-Channel System ................................................................. 324 160/176-Channel System.............................................................. 324 Requirements on Operating Wavelength ......................................... 325
Wavelength Allocation in 8/32/40-Channel Systems.................................... 325

Appendix B ................................................................................. 331 Configuration of Optical Supervision System............................ 331 2 M Supervision System................................................................ 331
Definition .......................................................................................................... 331 System Composition......................................................................................... 331 Hardware Configurations................................................................................. 332 Optional Hardware Configurations.................................................................. 333 EMS Software Configurations .......................................................................... 334

100 M Supervision System ............................................................ 335


Definition and Features.................................................................................... 335

System Composition......................................................................................... 336 Hardware Configurations................................................................................. 337 EMS Software Configurations .......................................................................... 338

Appendix C ................................................................................. 341 Configuration of Integrated Wavelength Supervision Subsystem .................................................................................................... 341 Overview ..................................................................................... 341 Subsystem Composition................................................................ 342 Hardware Configurations ............................................................... 343
Configurations of OTM...................................................................................... 343 Configurations of OADM................................................................................... 344

EMS Software Configurations......................................................... 345 Appendix D ................................................................................. 347 Configuration of OMS Layer Power Management Subsystem .. 347 Introduction to Automatic Power Management ................................ 347 Power Management of OMS Layer.................................................. 348 EMS Configurations....................................................................... 352
Creating an OMS Power Management Subsystem ......................................... 352 Configuring the OMS Power Management Subsystem................................... 354

Abbreviations ............................................................................. 357 Figures........................................................................................ 361 Tables ......................................................................................... 365 Index .......................................................................................... 371

This page is intentionally blank.

About this Hardware Manual


Purpose
The Unitrans ZXWM M900 Dense Wavelength Division Multiplexing Optical Transmission System (ZXWM M900 for short) is a kind of DWDM equipment developed by ZTE CORPORATION. Its operating wavelength is located at the C and L bands near the 1550 nm window, with the maximum transmission capacity of 1760 Gbit/s. The ZXWM M900 supports access of multiple services, featuring powerful protection and network management function. Applicable to backbone networks, local switching networks and various private networks, it can meet networking requirements and network management requirements at different levels. This manual describes the cabinet, components, and available boards of the ZXWM M900 equipment.

Confidential and Proprietary Information of ZTE CORPORATION

ZXMP M900 (V2.20) Hardware Manual

Whats in This Manual


This manual contains the following chapters and appendixes:
TABLE 1 CHAPTER SUMMARY

Chapter/Appendix Chapter 1 Cabinet

Summary Describes the appearance, dimensions and structure of ZTE unified cabinet for transmission equipment used by ZXWM M900. Describes the outline, structure, dimensions and functions of ZXWM M900s components. Provides detailed information about the function, operating principle, panels, interfaces, indicators and performance and alarm messages of all boards in the ZXWM M900. Introduces optical connections of ZXWM M900 equipment in 40/80/160 channel DWDM systems and corresponding wavelength requirements. Presents the concepts of 2 M supervision system and 100 M supervision systems, and introduced the software and hardware configurations of a 100 M supervision system. Describes the concept of centralized wavelength supervision subsystem and its software/hardware configurations. Describes the concept of optical multiplex section (OMS) layer power management subsystem and its software/hardware configurations. Lists the abbreviations of technical terms you may encounter while reading this manual

Chapter 2 Components

Chapter 3 Boards

Appendix A Optical Connections of ZXMP M900 Appendix B Configuration of Optical Supervision System Appendix C Configuration of Centralized Wavelength Supervision Subsystem Appendix D Configuration of OMS Layer Power Management Subsystem Abbreviation

ii

Confidential and Proprietary Information of ZTE CORPORATION

About this Hardware Manual

Related Documentation
There are four manuals associated with the ZXWM M900 equipment: Unitrans ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System Technical Manual Unitrans ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System Installation Manual Unitrans ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System Maintenance Manual Unitrans ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System RPOA Subsystem Users Manual

Confidential and Proprietary Information of ZTE CORPORATION

iii

ZXMP M900 (V2.20) Hardware Manual

Conventions
Typographical Conventions
ZTE documents employ with the following typographical conventions.
TABLE 2 TYPOGRAPHIC AL CONVENTIONS

Typeface Italics

Meaning

References to other guides and documents. Links on screens. Menus, menu options, function names, input fields, radio button names, check boxes, drop-down lists, dialog box names, window names. Keys on the keyboard and buttons on screens and company name. Text that you type, program code, files and directory names, and function names. Optional parameters Mandatory parameters Select one of the parameters that are delimited by it Note: Provides additional information about a certain topic. Checkpoint: Indicates that a particular step needs to be checked before proceeding further. Tip: Indicates a suggestion or hint to make things easier or more productive for the reader.

Quotes
Bold

CAPS
Constant width

[] {} |

Mouse Operation Conventions


TABLE 3 MOUSE OPERATION CONVENTIONS

Typeface Click Double-click Right-click

Meaning Refers to clicking the primary mouse button (usually the left mouse button) once. Refers to quickly clicking the primary mouse button (usually the left mouse button) twice. Refers to clicking the secondary mouse button (usually the right mouse button) once.

iv

Confidential and Proprietary Information of ZTE CORPORATION

About this Hardware Manual

Typeface Drag

Meaning Refers to pressing and holding a mouse button and moving the mouse.

Safety Signs
TABLE 4 SAFETY SIGNS

Safety Signs

Meaning

Danger: Indicates an imminently hazardous situation, which if not avoided, will result in death or serious injury. This signal word should be limited to only extreme situations. Warning: Indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. Caution: Indicates a potentially hazardous situation, which if not avoided, could result in minor or moderate injury. It may also be used to alert against unsafe practices. Erosion: Beware of erosion. Electric shock: There is a risk of electric shock. Electrostatic: The device may be sensitive to static electricity. Microwave: Beware of strong electromagnetic field. Laser: Beware of strong laser beam.
No flammables: No flammables can be stored.

No touching: Do not touch.

No smoking: Smoking is forbidden.

Confidential and Proprietary Information of ZTE CORPORATION

ZXMP M900 (V2.20) Hardware Manual

How to Get in Touch


The following sections provide information on how to obtain support for the documentation and the software.

Customer Support
If you have problems, questions, comments, or suggestions regarding your product, contact us by e-mail at support@zte.com.cn. You can also call our customer support center at (86) 755 26771900 and (86) 800-9830-9830.

Documentation Support
ZTE welcomes your comments and suggestions on the quality and usefulness of this document. For further questions, comments, or suggestions on the documentation, you can contact us by e-mail at doc@zte.com.cn; or you can fax your comments and suggestions to (86) 755 26772236. You can also explore our website at http://support.zte.com.cn, which contains various interesting subjects like documentation, knowledge base, forums and service request.

vi

Confidential and Proprietary Information of ZTE CORPORATION

Chapter

Cabinet
This chapter introduces the size, weight, outline and basic fittings of the unified cabinet for ZTE transmission equipment (ZTE cabinet for short). In addition, the cabinet configurations for the ZXWM M900 are described.

ZTE Cabinet
This section covers the structure of ZTE cabinet and basic fittings in it.

Structure
The ZTE cabinet is designed following unified industrial processes. It is a kind of 19-inch cabinet complying with IEC standards. And it features excellent performances of electromagnetic shield and heat dissipation. Table 5 lists the structural parameters of ZTE cabinet.
TABLE 5 STRUCTURAL P AR AMETERS OF ZTE CABINET

Dimensions (Height Width Depth) (mm) 2000 600 300 2200 600 300 2600 600 300 2000 600 600 2200 600 600 2600 600 600

Weight (kg) 59 65 77 102 114 128

Note: The weight listed in the table is that of the cabinet without fittings in.

Confidential and Proprietary Information of ZTE CORPORATION

ZXMP M900 (V2.20) Hardware Manual

For example, the outline and dimensions of the ZTE cabinet with the depth of 300 mm are illustrated in Figure 1 as follows.
FIGURE 1 OUTLINE AND DIMENSIONS OF ZTE CABINET (WITH DEPTH 300 MM)

Unit: mm

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 1 Cabinet

Basic Fittings in Cabinet


Take the ZTE cabinet with the dimensions of 2200 mm (height) 600 mm (width) 300 mm (depth) as example. Figure 2 illustrates the basic fittings in the cabinet.
FIGURE 2 BASIC FITTINGS IN ZTE CABINET

1. Outlet for Power Cables 2. Top Outlet 4. Door Lock 5. Front Door 7. Small Door of Cable Area 9. Grounding Copper Busbar 12. Cable Arranging Clip

3. Alarm Panel 6. Bottom Outlet 11. Fiber Cable Reel-in Box

8. Mounting Bracket 10. Cable Area

13. Cable Fixing Clip

Confidential and Proprietary Information of ZTE CORPORATION

ZXMP M900 (V2.20) Hardware Manual

Alarm Panel It is located at the upside of the front door. The running indicator on it indicates the working status of the equipment in the cabinet.

Front Door The front door of the cabinet has a lock. And on the top right corner of it, there is the equipment nameplate with blue ground and white characters to indicate the type of the equipment.

Outlet Outlets are located at both the top and bottom of the cabinet. Users can lay cables with either the upper cabling mode or lower cabling mode according to actual situation. Each outlet has a small active door on it to seal the cabinet after laying cables.

Cable Area The cable area is located close to the side door of the cabinet. There is a small detachable door which can be opened and closed in the cable area. The ring trip switch, ring trip reset button and the jack for antistatic wrist strap are located at the middle of the inner frame in the cable area. Generally, the mounting bracket, cable fixing plate, cable arranging clip and fiber cable reel-in box are mounted in the cable area. Mounting bracket: used to support components such as subrack of the equipment and power alarm subrack. It can be fixed at any position on the framework of the cabinet. Cable fixing plate: the cable arranging clip and fiber cable reel-in box are mounted on it. Cable arranging clip, fiber cable reel-in box: used to fix the internal cables and external optical cables. They are optional fittings for the ZXWM M900.

Mounting Hole Mounting holes are located at both the top and bottom of the cabinet. Users can use either top mounting holes or bottom mounting holes according to the actual fixing mode of the cabinet: top fixing, combined cabinet fixing, back-to-back fixing or bottom fixing.

Grounding Copper Busbar It is located at the back in the cabinet. The grounding terminals on the side door, front door, subrack, power alarm subrack and other components are connected to the grounding copper busbar with grounding wires to achieve good electrical connection of the equipment in the cabinet. Take the ZTE cabinet with the dimensions of 2200 mm (height) 600 mm (width) 300 mm (depth) as example. The grounding copper busbar in the cabinet and the grounding terminals on the cabinets side door and front door are illustrated in Figure 3.

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 1 Cabinet

FIGURE 3 GROUNDING TERMINALS IN CABINET

1. Grounding Copper Busbar in Cabinet 2. Grounding Terminals on Side Door 3. Grounding Terminal on Front Door

Heat Dissipation Aperture Heat dissipation apertures are distributed at the font door, rear door, top and bottom of the cabinet to guarantee good heat dissipation of the equipment.

Confidential and Proprietary Information of ZTE CORPORATION

ZXMP M900 (V2.20) Hardware Manual

Cabinet Configurations for ZXWM M900


Corresponding components should be mounted in the ZTE cabinet for ZXWM M900 equipment to perform different system functions. This section introduces the configurations based on the cabinet dimension and equipment type. For detailed information about components of ZXWM M900, please refer to Chapter 2 Components. Configurations based on the dimension of ZTE cabinet Table 6 lists the components which can be mounted in corresponding ZTE cabinets and their quantity.
TABLE 6 CABINET CONFIGURATIONS OF ZXWM M900

Component/Quantity Cabinet (mm) 2000 (H) 600 (W) 300 (D) 2200 (H) 600 (W) 300 (D) 2600 (H) 600 (W) 300 (D) 2000 (H) 600 (W) 600 (D) 2200 (H) 600 (W) 600 (D) 2600 (H) 600 (W) 600 (D)

Power Alarm Subrack 1 1 1 1 1 1

Subrack 2 3 3 4 6 6

ODF Plug-in Box 1 1 1 2 2 2

DCM Plug-in Box 1 1 2 2 2 4

Note: Additional information about cabinet configurations: For ZTE cabinets with the depth of 600 mm, the doors should be mounted in both the front and the rear of the cabinets if the subracks are required to be mounted back-to-back. If the doors are only mounted in the front of the cabinets, the configurations for ZTE cabinets with the depth of 600 mm are the same as those with the depth of 300mm. The optical distribution frame (ODF) plug-in box and dispersion compensation module (DCM) plug-in box are optional components. Table 6 recommends the maximum configuration quantity of them. Equipment of other manufacturers can also be mounted in the cabinet according to user's requirements, such as routers. However, the outline and dimension of the equipment should meet the mounting requirements of ZTE cabinet. Three kinds of subracks are provided for the ZXWM M900. They are optical transponder unit (OTU) subrack, optical amplifier (OA) subrack, and transparent multiplexer (TMUX) subrack. For the main rack, which is configured with NCP or NCPF board, at least one OA subrack should be mounted.

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 1 Cabinet

Configurations based on the type of ZXWM M900 equipment The ZXWM M900 can be configured as optical terminal (OTM), optical add/drop multiplexer (OADM) or optical line amplifier (OLA) through plugging various functional boards and service boards in the subracks. OTM Generally, multiple racks are configured in an OTM. The one configured with the NCP or NCPF board is the main rack. The others are extended racks. Multiple subracks are mounted in each cabinet. The main rack consists of a power alarm subrack, multiple OTU/TMUX subracks and an OA subrack (with NCP or NCPF board in). The extended rack consists of a power alarm subrack and multiple OTU/TMUX subracks. OLA Generally, only one rack is configured in an OLA. It consists of a power alarm subrack and an OA subrack. OADM Generally, only one rack is configured in an OADM. It consists of a power alarm subrack, one or two OTU/TMUX subracks and an OA subrack.

Take a cabinet with the height of 2200 mm for example. Figure 4 illustrates the position of components in the cabinet as typical OTM equipment.

Confidential and Proprietary Information of ZTE CORPORATION

ZXMP M900 (V2.20) Hardware Manual

FIGURE 4 COMPONENTS POSITION IN CABINET

Power Alarm Subrack Common Interface Area Fan Fan Fan OTU Subrack 1

Boards

Optical Cable Area Dustproof Net Common Interface Area Fan Fan Fan

Boards

OA Subrack

Optical Cable Area Dustproof Net ODF Common Interface Area Fan Fan Fan OTU Subrack 2 or DCM/SWE

Boards

Optical Cable Area Dustproof Net DCM No Components or SWE

User equipment can be mounted at the position where the ODF/DCM plug-in box is located. However, the prerequisite is that the outline and dimension of user equipment should meet the mounting requirements of ZTE cabinet. It is recommended to reserve the distance of 2U between OA subrack and OTU subrack 2 for the mounting of an ODF plug-in box or two DCM/SWE plug-in boxes as needed. At least 1U space at the bottom of the cabinet should be reserved, so as to ensure enough space for the installation of cabinet on ground. Otherwise the rear door can not be mounted and the connection of grounding wires would be affected.

Confidential and Proprietary Information of ZTE CORPORATION

Chapter

Components
This chapter describes the structure and functions of the OA/OTU/TMUX subrack, power alarm subrack, and ODF/DCM plug-in box of the ZXWM M900.

OA Subrack
The frame of OA subrack is simple with aluminium front/rear beams, left/right side panels and guide rails. The dimensions are 577 mm (height) 482.6 mm (width) 269.5 mm (depth). Figure 5 illustrates the structure of OA subrack.
FIGURE 5 STRUCTURE OF OA SUBRACK

1. Backplane 7. Fan Area

2. Lug

3. Fiber Cable Reel-in Box

4. Dustproof Net 5. Chute 6. Board Area 8. Orderwire Phone Bracket

Confidential and Proprietary Information of ZTE CORPORATION

ZXMP M900 (V2.20) Hardware Manual

Backplane The backplane supports connections between boards in the subrack. It also provides interfaces through which external signals can be input to the ZXWM M900 equipment. The backplane can be divided into three area, common interface area, fan interface area and board interface area. Common interface area: it is located at the upside of the backplane, providing the subrack power socket, and signal interfaces such as network interface, transparent user channel interface, and alarm input/output interface. For the detailed information of the common interface area, please refer to the section Common Interface Area in this chapter. Fan interface area: it is located at the middle of the backplane, providing power socket and signal sockets for three independent fan units. Board interface area: it is located at the lower side of the backplane, providing power sockets and signal sockets for boards. The transceiving data bus for signal sockets is differential data bus. Signals are transferred to the backplane at the same time through parallel operation, where the signals are input or output.

Board area 14 board slots with guide rails are provided in this area. The space between board slots is 30 mm. For the detailed information of the board slots, please refer to the section Board Slots in this chapter.

Fan area Located above the board area, the fan area provides space for three independent fan units. The fan units are connected to the backplane through connectors. For the detailed information, please refer to the section Independent Fan Unit in this chapter.

Orderwire phone bracket Located at the front of the common interface area, the bracket is used to support the orderwire phone. For the detailed information, please refer to the section Orderwire Phone Bracket in this chapter.

Note: Only the OA subrack is configured with the orderwire phone bracket.

Chute Located at the lower part of the subrack, it is used for the layout of optical cables connected to boards.

Lug The left and right lugs are provided. The subrack is fixed in the cabinet through captive fasteners across the lugs.

Dustproof net Located at the underside of the subrack, it is combined with the fan units to form an air circulation system in the subrack. Figure 6 illustrates the outline of the dustproof net.

10

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

An additional plaque is installed to shield the dustproof net after mounting it, as shown in Figure 5
FIGURE 6 OUTLINE OF DUSTPROOF NET

Fiber cable reel-in box Located on the left and right side panels in the subrack, they are used to reel in overlong pigtails. The reel-in box can be pulled out along the guide rail on the top and bottom of it. Generally, overlong pigtails between subracks are reeled in the left box, while pigtails for internal connections of the subrack are reeled in the right box. For example, the structure and pulling-out direction of the left fiber cable reel-in box are illustrated in Figure 7.
FIGURE 7 LEFT FIBER CABLE REEL-IN BOX

1. Fixing Plate for Reel-in Box 4. Left Panel of Subrack

2. Wheel

3. Guide Rail

Confidential and Proprietary Information of ZTE CORPORATION

11

ZXMP M900 (V2.20) Hardware Manual

Board Slots
The boards in OA subrack can be arranged in three modes depending on the rate of supervisory system and functions to be performed. For the introduction of supervisory system, please refer to Appendix B Configurations of Optical Supervisory System. Boards arrangement for 2 M supervisory system (without APSF) The arrangement of boards in the OA subrack is illustrated in Figure 8, where the numerals indicate the serial number of slots.
FIGURE 8 BOARDS ARR ANGEMENT IN OA SUBRACK (FOR 2 M SUPERVISORY SYSTEM W I T H O U T AP S F )

Common Interface Area Fan Area O H P 1 2 3 4 5 6 Fan Area O S C 7 N C P 8 9 10 11 12 13 14 Fan Area

Optical Cable Area

Table 7 shows the relationship between the slots and corresponding pluggable boards in the OA subrack.
TABLE 7 WITHOUT RELATIONS BETWEEN BOARDS AND SLOTS (FOR 2 M SUPERVISORY SYSTEM AP S F )

Slot 6

Pluggable Board OHP

Remark Each OHP board occupies one slot. Each OSC board occupies one slot. If two OSC boards are required, they should be plugged in the slot 5 and 7 respectively. If only one OSC board is required, it should be plugged in the slot 7.

5, 7

OSC

NCP Optical transponder boards Convergence boards

Each NCP board occupies one slot. The NCPF board can also be plugged in instead of NCP board here.

1-4 9-14

Mux/DeMux boards Optical boards amplifier

No restriction for slots.

Power management boards

12

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

Slot

Pluggable Board Protection boards

Remark

Boards arrangement for 2 M supervisory system (with APSF) In the 2 M supervisory system, the APSF board must be configured in the subrack when the interworking function of automatic protection switching (APS) bus is required in the ZXWM M900 equipment. The interworking of APS bus is mainly used in the following two situations: The ZXWM M900 would manage APS buses of multiple racks through the APSF board, for example, to perform the automatic power reduction (APR) function in multiple directions. The APSF board is used to transfer APS bus information between the main rack and extended racks in this case. The ZXWM M900 would implement the access of external clock and perform the function of unified clock distribute through the CA board configured in the TMUX subrack. In this case, the APSF board is used to transfer clock information.

The arrangement of boards in the OA subrack is illustrated in Figure 9, where the numerals indicate the serial number of slots.
FIGURE 9 BOARDS ARR ANGEMENT IN OA SUBRACK (FOR 2 M SUPERVISORY SYSTEM WITH APSF)

Common Interface Area Fan Area O H P 1 2 3 4 5 6 Fan Area O S C 7 N C P 8 A P S F 9 10 11 12 13 14 Fan Area

Optical Cable Area

Table 8 shows the relationship between the slots and corresponding pluggable boards in the OA subrack.
TABLE 8 RELATIONS BETWEEN BOARDS AND SLOTS (FOR 2 M SUPERVISORY SYSTEM WITH APSF)

Slot 6

Pluggable Board OHP

Remark Each OHP board occupies one slot. Each OSC board occupies one slot. If two OSC boards are required, they should be plugged in the slot 5 and 7 respectively. If only one OSC board is required, it should be plugged in the slot 7.

5, 7

OSC

NCP

Each NCP board occupies one slot. The NCPF board can also be plugged in instead of NCP board here.

Confidential and Proprietary Information of ZTE CORPORATION

13

ZXMP M900 (V2.20) Hardware Manual

Slot 9

Pluggable Board APSF Optical transponder boards Convergence boards Mux/DeMux boards

Remark Each APSF board occupies one slot.

1-4, 10-14

Optical boards

amplifier

No restriction for slots.

Power management boards Protection boards

Boards arrangement for 100 M supervisory system The arrangement of boards in the OA subrack is illustrated in Figure 10, where the numerals indicate the serial number of slots.
FIGURE 10 BOARDS ARR ANGEMENT IN OA SUBRACK (FOR 100 M SUPERVISORY SYSTEM)

Common Interface Area Fan Area O H P F 1 2 3 4 5 6 Fan Area O S C F 7 N C P F 8 A P S F 9 10 11 12 13 14 Fan Area

Optical Cable Area

Table 9 shows the relationship between the slots and corresponding pluggable boards in the OA subrack.
TABLE 9 RELATIONSHIP BETWEEN BOARDS AND SLOTS (FOR 100 M SUPERVISORY SYSTEM)

Slot 6

Pluggable Board OHPF

Remark Each OHPF board occupies one slot. Only the main rack is configured with it. Each OSCF board occupies one slot. Only the main rack is configured with it.

OSCF

For one or two optical directions, one OSCF should be plugged in slot 7. For three optical directions or above, multiple OSCF boards can be plugged in, and each board can only provide two optical directions at most. One of OSCF

14

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

Slot

Pluggable Board

Remark boards should be plugged in the slot 7. The others can be plugged in any spare slots.

8 9

NCPF APSF Optical transponder boards Convergence boards

Each NCPF board occupies one slot. Only the main rack is configured with it. Each APSF board occupies one slot. Only the main rack is configured with it.

1-5 10-14

Mux/DeMux boards Optical boards amplifier

No restriction for slots.

Power management boards Protection boards

Common Interface Area


16 interfaces, one DIP switch and two slots are provided in the common interface area of the OA subrack, as illustrated in Figure 11. The silkscreen (Jx, x=1-9, 11-17) on the panel indicates the corresponding interface. The J10 is the DIP switch.
FIGURE 11 COMMON INTERFACE ARE A ON BACKPLANE OF O A SUBRACK

1. Slots for Subrack PBX (Power Box Board)

Note: This manaul only describes the basic definition of interfaces. For further information about the optical connection of interfaces, refer to Unitrans ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System Installation Manual.

Confidential and Proprietary Information of ZTE CORPORATION

15

ZXMP M900 (V2.20) Hardware Manual

DIP Switch and Serial Number of Rack/Subrack


An 8-pin DIP switch (J10) is used to set the serial number of racks and subracks when multiple racks/subracks are configured in a NE. Figure 12 illustrates the pins order of the DIP switch. It indicates 0 when the pin is toggled up to the position ON. On the contrary, it indicates 1. The serial number is calculated from the position of pins with the binary system.
FIGURE 12 PINS ORDER OF DIP SWITCH (J10)

ON

DIP

1 2 3 4 5 6 7 8

Note: The pin 5 of the DIP switch is reserved.

Serial number of cabinet Pin 1-4 of the DIP switch are used to set the serial number of racks. At present, one NCP or NCPF board can manage four racks. The serial number of rack is from 0 to 3. The rack 0 is the main rack, while the others are extended racks. Table 10 lists the position of pin 1-4 and corresponding serial number of rack.

TABLE 10 SERIAL NUMBER OF RACKS

DIP Pin Cabinet Cabinet 0 Cabinet 1 Cabinet 2 Cabinet 3

1 Digit 3 0 0 0 0

2 Digit 2 0 0 0 0

3 Digit 1 0 0 1 1

4 Digit 0 0 1 0 1

Note: Cabinet 0 means the main cabinet; Cabinet 1 means extended cabinet 1, and so on.

Serial number of subrack Pin 6-8 of the DIP switch are used to set the serial number of subracks. At present, four subracks can be mounted in a rack at most. The serial number of subrack is from 1 to 4. Table 11 lists the position of pin 6-8 and corresponding serial number of subrack.

16

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

TABLE 11 SERIAL NUMBER OF SUBRACKS

DIP Pin Subrack Subrack 1 Subrack 2 Subrack 3 Subrack 4

6 Digit 2 0 0 0 1

7 Digit 1 0 1 1 0

8 Digit 0 1 0 1 0

Note: The serial number of subrack is arranged based on the position of subrack from the top down. For example, the uppermost subrack mounted in the rack is defined as subrack 1.

Slots for PBX Boards


Two slots for PBX boards are located in the middle of the common interface area. Insert two PBX boards to provide power supply to each board in the OA subrack. By default, the PBX board of master power supply is plugged in the lower slot with the identifier -48V_In1, while the PBX board of slave power supply is plugged in the upper slot with identifier -48V_In2.

Interfaces on Backplane
The types and functions of these interfaces are listed in Table 12.
TABLE 12 TYPE AND FUNCTION OF INTERFACES ON O A BACKPLANE

Silkscreen

Name

Type 3-pin power socket DB9 socket (male)

Function The master and slave power supply for the OA subrack is input through the interface. It is used to connect with client equipments. The equipment alarms from NCP boards are output to the Warn interface on the power supervision board (PWSB) through the interface. The PWSB board locates in the DCM plug-in box of power alarm subrack. The orderwire phone of the ZXWM M900 is connected to any of these two

J1/J17

-48 V power interface

J2

RS232 interface

J3

Alarm output interface

DB9 socket (female)

J4/J5

Orderwire interface

RJ11 socket

Confidential and Proprietary Information of ZTE CORPORATION

17

ZXMP M900 (V2.20) Hardware Manual

Silkscreen

Name

Type

Function interfaces. The external clock 2 Mbit/s and 2 MHz is input through any of two interfaces. It is used to connect with the client equipments. The network management system is accessed through the interface when the supervision rate is 2 Mbit/s and the NCP board is the main control board. It is reserved for testing. The over-voltage/under-voltage alarms of subrack master/slave power supply and in-position signal of PBX are output to the PWSB board through the interface. When multiple racks are configured in the NE, the subrack can be connected to subracks in other racks with data cables through the interface. The data cable of extended rack 1 is connected to the J14 interface on the OA subrack of cabinet. The data cable of extended rack 2 is connected to the J13 interface on the OA subrack of cabinet. The data cable of extended rack 3 is connected to the J15 interface on the OA subrack of cabinet.

J6/J7

External clock interface

CC4 coaxial socket DB9 socket (male)

J8

RS422 interface

J9

Electrical interface

Ethernet

RJ45 socket

J11

System test interface

DB9 socket (male)

J12

Power alarm interface

DB9 socket (female)

J13/J14/J15

Extended interface

data

PCB solder 36-pin D-type straight socket (female blade)

J16

Local data interface

PCB solder 36-pin D-type straight socket (female blade)

When multiple subracks are configured in the ZXWM M900 equipment, the subrack can be connected to another subrack in the rack with data cable.

18

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

The signal definitions of pins in some sockets are described as follows. 3-pin power socket (J1/J17)

Figure 13 illustrates the pins of the socket.


FIGURE 13 PINS OF J1/J17 POWER SOCKET

A1

A2

A3

The signal definitions of pins in J1/J17 socket are listed in Table 13.
TABLE 13 SIGNAL DEFINITION OF PINS IN J1/J17 SOCKET

Pin A1 A2 A3

Signal Definition -48 V ground Protection ground -48 V

DB9 socket (male) (J2/J8/J11)

Figure 14 illustrates the pins in the DB9 socket (male).


FIGURE 14 DB9 SOCKET (M ALE)
1 2 3 4 5

6 7 8 9

The signal definitions of J2 socket are listed in Table 14.


TABLE 14 SIGNAL DEFINITIONS OF PINS IN J2 SOCKET

Pin 2 3 5

Signal Definition USER_232_RXD USER_232_TXD GND

Description Input, RS232 data signals received Output, RS232 data signals transmitted Ground

Confidential and Proprietary Information of ZTE CORPORATION

19

ZXMP M900 (V2.20) Hardware Manual

The signal definitions of J8 socket are listed in Table 15.


TABLE 15 SIGNAL DEFINITION OF PINS IN J8 SOCKET

Pin 1 6 2 7

Signal Definition USER_422_TXD+ USER_422_TXDUSER_422_RXD+ USER_422_RXD-

Description Output, RS422 transmitting (positive) Output, RS422 transmitting (negative) Output, RS422 receiving (positive) Output, RS422 receiving (negative)

The signal definitions of J8 socket are listed in Table 16.


TABLE 16 SIGNAL DEFINITION OF PINS IN J11 SOCKET

Pin 1 6 2 7

Signal Definition TEST_TX+ TEST_TXTEST_RX+ TEST_RX-

Description Output, data transmitted (positive) Output, data transmitted (negative) Input, data received (positive) Input, data received (negative)

DB9 socket (female) (J3/J12)

Figure 15 illustrates the pins in the DB9 socket (female).


FIGURE 15 DB9 SOCKET (FEM ALE)
5 4 3 2 1

9 8 7 6

The signal definitions of J3 socket are listed in Table 17.


TABLE 17 SIGNAL DEFINITION OF PINS IN J3 SOCKET

Pin 1 6 2 7 3 8

Signal Definition RING_C1 RING_C0 YELLOW_C1 YELLOW_C0 RED_C1 RED_C0

Description Output, alarm bell signal (positive) Output, alarm bell signal (negative) Output, yellow alarm indicator signal (positive) Output, yellow alarm indicator signal (negative) Output, red alarm indicator signal (positive) Output, red alarm indicator signal (negative)

20

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

Pin 4 9 5

Signal Definition ALM_PWR_1+ ALM_PWR_1GND

Description Input, PWSB alarm signal (positive) Input, PWSB alarm signal (negative) Ground

Note: The above table lists four pairs of on-off signal isolated by optical coupler or relay.

The signal definitions of J12 socket are listed in Table 18.


TABLE 18 SIGNAL DEFINITIONS OF PINS IN J12 SOCKET

Pin 1 6 2 7 3 8 4 9 5

Signal Definition Vinu1 Vino1 ONLINE1 Voutu ALMCOM Vouto ONLINE2 Vino2 Vinu2

Description Under-voltage alarm signal of subrack input power supply 1 Over-voltage alarm signal of subrack input power supply 1 In-position signal of PBX1 board in subrack Under-voltage alarm signal of subrack output power supply Common end of alarm Over-voltage alarm signal of subrack output power supply In-position signal of PBX2 board in subrack Over-voltage alarm signal of subrack input power supply 2 Under-voltage alarm signal of subrack input power supply 2

OTU Subrack
The frame of OTU subrack is similar as that of OA subrack with aluminium front/rear beams, left/right side panels and guide rails. The dimensions are 577 mm (height) 482.6 mm (width) 269.5 mm (depth). Figure 16 illustrates the structure of OTU subrack.

Confidential and Proprietary Information of ZTE CORPORATION

21

ZXMP M900 (V2.20) Hardware Manual

FIGURE 16 STRUCTURE OF OTU SUBRACK

1. Backplane 7. Fan Area

2. Lug 8. Plaque

3. Fiber Cable Reel-in Box

4. Dustproof Net 5. Chute 6. Board Area

The components and their functions are described in Table 19.


TABLE 19 FUNCTIONS OF COMPONENTS IN OTU SUBRACK

Component

Function

At the upside of the backplane, the common interface area provides the subrack power socket and signal interfaces such as network interface, transparent user channel interface, and alarm input/output interface. For detailed
information of the common interface area, please refer to the section common interface area in this chapter.

Backplane

At the middle of the backplane, the fan interface area provides power socket and signal sockets for three independent fan units. At the lower side of the backplane, the board interface area provides power sockets and signal sockets for boards.

Board Area

14 board slots with guide rails are provided in this area. The space between board slots is 30 mm. For the detailed information of the board slots, please refer to the section Board Slots in this chapter. Located above the board area, the fan area provides space for three independent fan units. For the detailed information of independent fan unit, please refer to the section Independent Fan unit in this chapter. Located at the underside of the subrack, the dustproof net is combined with the fan units to form an air circulation system in the

Fan Area

Dustproof Net

22

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

Component

Function subrack. Located on the left and right side panels in the subrack, they are used to reel in overlong pigtails. The reel-in box can be pulled out along the guide rail on the top and bottom of it. Located at the lower part of the subrack, the chute is used for the layout of optical cables connected to boards. Located at the front of dustproof net, the plaque is used to shield the interface area and dustproof net. The left and right lugs are provided. The subrack is fixed in the cabinet through captive fasteners across the lugs. Captive fasteners are used to fix the plaque on the OTU subrack. They are also used to mount the subrack in the cabinet.

Fiber Cable Reel-in Box Chute Plaque Lug Captive Fastener

Note: The structure and componets of OTU subrack are similar to that of the OA subrack. Refer to OA Subrack for detailed introduction to the components.

Board Slots
The board slots in OTU subrack are illustrated in Figure 17, where the numeral indicates the serial number of slots.
FIGURE 17 BOARD SLOTS IN OTU SUBRACK

Common Interface Area Fan Area Fan Area Fan Area

10

11

12

13

14

Optical Cable Area

Service boards can be plugged in any slots of the OTU subrack, such as main optical channel board, service convergence boards and optical transponder boards.

Confidential and Proprietary Information of ZTE CORPORATION

23

ZXMP M900 (V2.20) Hardware Manual

Common Interface Area


6 interfaces, one DIP switch and two slots are provided in the common interface area of the OTU subrack, as illustrated in Figure 18.
FIGURE 18 COMMON INTERFACE ARE A ON BACKPLANE OF OTU SUBRACK

1. Slots for Subrack PBX (Power Box Board)

Note: This manaul only describes the basic definition of interfaces. For further information about the optical connection of interfaces, refer to Unitrans ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System Installation Manual.

Type and Functions of Interfaces Table 20 lists the types and functions of interfaces in the common interface area.

TABLE 20 TYPE AND FUNCTION OF INTERFACES ON OTU BACKPLANE

Silkscreen J1/J7 J2

Name -48 V power interface System test interface

Type 3-pin power socket DB9 socket (male)

Function The master and slave power supply for the OTU subrack is input through the interface. It is reserved for testing. The over-voltage/under-voltage alarms of subrack master/slave power supply and in-position signal of PBX are output to the DCMU plug-in box on the power alarm subrack through any interface from SP_ALM to SP_ALM4. When multiple subracks are configured in the ZXWM

J4

Power alarm interface

DB9 socket (female)

J5/J6

Local data interface

PCB solder 36-pin D-type straight

24

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

Silkscreen

Name

Type socket blade) (female

Function M900 equipment, the subrack can be connected to another subrack in the rack with data cable.

Note: The signal definitions of pins in the J1/J7, J2 and J4 sockets are the same as that of corresponding sockets in the common interface area of OA subrack. Please refer to corresponding contents in the section OA Subrack for signal definitions of J1/J7, J2 and J4 sockets. J1/J7 (OTU subrack) -> J1/J17 (OA subrack, Table 13) J2 (OTU subrack) -> J11 (OA subrack, Table 16) J4 (OTU subrack) -> J12 (OA subrack, Table 18)

DIP Switch (J3) The 8-pin DIP switch (J3) is used to set the serial number of racks and subracks when multiple racks/subracks are configured in a NE. The definitions of pins order of the DIP switch and corresponding rack/subrack number are same as those of the DIP switch (J10) in the common interface area of OA subrack.

Slots for PBX Boards Two slots for PBX boards are located in the middle of the common interface area. Two PBX boards can be plugged in to provide power supply to each board in the OTU subrack. By default, the PBX board of master power supply is plugged in the lower slot with the identifier -48V_In1, while the PBX board of slave power supply is plugged in the upper slot with identifier -48V_In2.

TMUX Subrack
The structure, dimensions and components of TMUX subrack is same as those of the OTU subrack.

Board Slots
The board slots in TMUX subrack are illustrated in Figure 19, where the numeral indicates the slot No.

Confidential and Proprietary Information of ZTE CORPORATION

25

ZXMP M900 (V2.20) Hardware Manual

FIGURE 19 BOARD SLOTS IN TMUX SUBRACK

Common Interface Area Fan Area Fan Area C A 1 2 3 4 5 6 7 C A 8 9 10 11 12 13 14 Fan Area

Optical Cable Area

Table 21 shows the relationship between the slots and corresponding pluggable boards in the TMUX subrack.
TABLE 21 RELATIONSHIP BETWEEN BOARDS AND SLOTS IN TMUX SUBRACK

Slot 7, 8

Pluggable Board CA DSAE, SMU

Remark By default, the slot 7 is for the master CA board, while the slot 8 is for the standby CA board. Cooperate with CSU board.

1-6, 9-14

Boards of convergence type are recommended.

SRM41, SRM42

Cooperate with CSU board.

Other boards can also be plugged in. The board can be plugged in any one of these slots.

26

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

Common Interface Area


14 interfaces, one DIP switch and two slots are provided in the common interface area of the TMUX subrack, as illustrated in Figure 20. The silkscreen (Jx, x=1-10, 12-14) on the panel indicates the corresponding interface. The J11 is the DIP switch.
FIGURE 20 COMMON INTERFACE ARE A ON TMUX BACKPLANE

1. Slots for Subrack PBX (Power Box Board)

Note: This manaul only describes the basic definition of interfaces. For further information about the optical connection of interfaces, refer to Unitrans ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System Installation Manual.

Type and Functions of Interfaces Table 22 lists the types and functions of interfaces in the common interface area.

TABLE 22 TYPES AND FUNCTIONS OF INTERFACE ON TMUX BACKPL ANE

Silkscreen J1/J15 J2

Name -48 V power interface System test interface 2 MHz clock input interface 2 Mbit/s clock input interface 2 MHz clock output interface

Type 3-pin power socket DB9 socket (male) CC4 coaxial socket CC4 coaxial socket CC4 coaxial socket

Function The master and slave power supply for the TMUX subrack is input through the interface. It is reserved for testing. The external clock 2 MHz is input through the interface. The external clock 2 Mbit/s is input through the interface. The clock 2 MHz is output through this interface

J3/J4

J5/J6

J7/J8

Confidential and Proprietary Information of ZTE CORPORATION

27

ZXMP M900 (V2.20) Hardware Manual

Silkscreen J9/J10

Name 2 Mbit/s clock output interface

Type CC4 coaxial socket

Function The clock 2 Mbit/s is output through this interface. The over-voltage/under-voltage alarms of subrack master/slave power supply and in-position signal of PBX board are output to the DCM plug-in box on the power alarm subrack through any interface from SP_ALM1 to SP_ALM4.

J12

Power alarm interface

DB9 socket (female)

J13/J14

Local data interface

PCB solder 36-pin D-type straight socket (female blade)

When multiple subracks are configured in the ZXWM M900 equipment, the subrack can be connected to another subrack in the rack with data cable.

Note: The signal definitions of pins in the J1/J15, J2 and J12 sockets are the same as that of corresponding sockets in the common interface area of OA subrack. Please refer to corresponding contents in the section OA Subrack for signal definitions of J1/J15, J2 and J12 sockets. J1/J15 (TMUX subrack) -> J1/J17 (OA subrack, Table 13) J2 (TMUX subrack) -> J11 (OA subrack, Table 16) J12 (TMUX subrack) -> J12 (OA subrack, Table 18)

DIP Switch (J11) The 8-pin DIP switch (J11) is used to set the serial number of racks and subracks when multiple racks/subracks are configured in a NE. The definitions of pins order of the DIP switch and corresponding rack/subrack number are same as those of the DIP switch (J10) in the common interface area of OA subrack.

Slots for PBX Boards Two slots for PBX boards are located in the middle of the common interface area. Two PBX boards can be plugged in to provide power supply to each board in the TMUX subrack. By default, the PBX board of master power supply is plugged in the lower slot with the identifier -48V_In1, while the PBX board of slave power supply is plugged in the upper slot with identifier -48V_In2.

28

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

Orderwire Phone Bracket


The orderwire phone bracket is used to support the orderwire phone set. It dimensions are 132.5 mm (height) 482.6 mm (width) 269.5 mm (depth). Figure 21 illustrates the structure of the bracket.
FIGURE 21 STRUCTURE OF ORDERWIRE PHONE BRACKET

1. Captive Fastener

2. Line Hole

3. Bracket

The function of the orderwire phone brackets components are described in Table 23.
TABLE 23 COMPONENTS FUNCTIONS OF ORDERWIRE PHONE BRACKET

Component Captive Fastener Line Hole Bracket

Function Fixes the bracket on the subrack. Lays the line of orderwire phone through it. Supports the orderwire phone set.

Independent Fan Unit


Three independent fan units are provided to the OA/OTU/TMUX subrack in the ZXWM M900. They are plugged in the fan area of the subrack. The dimensions of each fan unit are 43.6 mm (height) 145 mm (width) 247.5 mm (depth). Figure 22 illustrates the structure of the independent fan unit.

Confidential and Proprietary Information of ZTE CORPORATION

29

ZXMP M900 (V2.20) Hardware Manual

FIGURE 22 STRUCTURE OF INDEPENDENT FAN UNIT

1. Fan Control Board (FCB) 3. Locking Switch

2. Fan 4. Indicator 5. Handle

The functions of the fan units components are described in Table 24.
TABLE 24 FUNCTIONS OF COMPONENTS IN INDEPENDENT FAN UNIT

Component FCB Indicator Fan Handle Locking Switch

Function Provides power interface and signal interface for the connection to the backplane. Indicates the working status of FCB. One independent fan is configured in each fan unit. Exhaust mode is adopted. Helps to pull in or out the fan unit, and thus facilitate the mounting and maintenance of the fan unit. Used to lock the fan unit after pulling it in, or unlock the fan unit before pulling it out.

These three independent fan unit are controlled respectively. Thus when one of them is in fault, the other two can still work normally. In this case, the faulty fan unit can be pulled out along the direction illustrated in Figure 23 for maintenance after being unlocked.

30

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

FIGURE 23 M AINTENANCE OF INDEPENDENT FAN UNIT

1. Subrack

2. Independent Fan Unit

Power Alarm Subrack


The power alarm subrack consists of the power distribution subrack and the monitoring plug-in box. It is mounted at the uppermost shelf of the cabinet, as illustrated in Figure 4. The structure of the power alarm subrack is as shown in Figure 24.
FIGURE 24 STRUCTURE OF POWER AL ARM SUBRACK

1. Power Distribution Subrack

2. Monitoring Plug-in Box

Confidential and Proprietary Information of ZTE CORPORATION

31

ZXMP M900 (V2.20) Hardware Manual

Power Distribution Subrack


The power distribution subrack is used to distribute power supply to other subracks in the cabinet. The external master/slave power supply is input to the power distribution subrack. After the processes of wave filtering and lightning protection, the subrack distributes the master/slave power supply to the other subracks in the ZXWM M900 equipment. The dimensions of the power distribution subrack are 177 mm (height) 482.6 (width) 269.5 mm (depth). Figure 25 illustrates the structure of the power distribution subrack.
FIGURE 25 STRUCTURE OF POWER DISTRIBUTION SUBRACK

1. Lug 3. Grounding Sign 6. Slave Power Supply Area 8. Front Panel 10. Cable Hole 5. Connection Terminal for External Power Supply Input

2. Grounding Terminal 4. Master Power Supply Area 7. Alarm Indicator Board (LED) 9. Captive Fastener

The functions of components in the power distribution subrack are described in Table 25

32

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

TABLE 25 FUNCTIONS OF COMPONENTS IN POWER DISTRIBUTION SUBRACK

Component Connection Terminal for External Power Supply Input Master Area Power Supply

Function Providing two group of connection terminals for the input of external -48 V power supply. Each group includes three terminals, -48 V, -48 V GND and PGND. By default, the left group is for the input of master power supply, while the right one is for the slave power supply. For standard configuration, four pairs of master/slave power supply are provided. For full configuration, six pairs of master/slave power supply are provided. Each group includes three terminals, -48 V, -48 V GND and PGND, which is controlled through the air switch. It provides power supply 1+1 protection for the subrack. Located at both the left and right panel of the power distribution subrack. The power distribution subrack would be grounded through connecting the grounding terminals to the grounding copper busbar of the cabinet. Indicators on this board indicate the status of the cabinet simultaneously with indicators of the alarm board on the front door of the cabinet. The green, yellow, and red indicator indicates the status of normal, warning, and critical alarm respectively. The front panel is a plaque with identifiers for air switches and warning signs. Positions on both the left and right of the front panel are reserved for air switches of master/slave power supply. The silkscreen identifiers of power supply, serial number and on/off status are printed at corresponding position. With standard configuration, the air switches with the identifier -48V_In1 1~4 is for master power supply, while those with -48V_In2 1~4 is for slave power supply. The position reserved for indicators on the alarm indicator board is in the middle of the front panel. The warning sign on the left bottom corner of the front panel to alert that it can only be operated by professional persons. The electric shock sign on the right bottom corner warns there is a risk of electric shock.

Slave Power Supply Area

Grounding Terminal Grounding Sign

Alarm Indicator Board (LED)

Front Panel

Lug Captive Fastener

Fasten the screws on the left and right lugs to fix the power distribution plug-in subrack in the cabinet. Used to fix the front panel of power distribution subrack and the subrack itself. Located at the left and right panel of the power distribution subrack. Power cables connected to the subrack are laid through them.

Cable Hole

Monitoring Plug-in Box


The monitoring plug-in box is used to support and shield the power supervision board (PWSB), which monitors the power supply. The PWSB board also provides interfaces such as subrack power alarm interface, alarm

Confidential and Proprietary Information of ZTE CORPORATION

33

ZXMP M900 (V2.20) Hardware Manual

output interface, ring strip interface, external alarm input interface, 36-pin data bus socket. The dimensions of the monitoring plug-in box are 43.6 mm (height) 482.6 mm (width) 257 mm (depth). Figure 26 illustrates the structure of the monitoring plug-in box.
FIGURE 26 STRUCTURE OF MONITORING PLUG-IN BOX

1. Captive Fastener 4. Cabling Beam

2. Lug

3.PWSB

5. Plaque

The functions of components in the monitoring plug-in box are described in Table 26.
TABLE 26 FUNCTIONS OF COMPONENTS IN MONITORING PLUG-IN BOX

Component PWSB Cabling Beam Plaque Lug Captive Fastener

Function As the core of the monitoring plug-in box, it monitors the power supply and provides various interfaces for external signals. Cables connected to the monitoring plug-in box can be tied on the beams at both sides of the plug-in box. Turn the plaque horizontal before laying and tying cables. And after that close the plaque to shield the interfaces in the plug-in box. Fix the captive fasteners on the lugs to secure the monitoring plug-in box in the cabinet.

ODF Plug-in Box


The ODF plug-in box is optional for reserved optical fiber cables and their connections and assignments. 52 fiber cables can be reeled in it at most. Generally, the ODF plug-in box is placed on the under layer of the subrack, as shown in Figure 4. Dimensions: 88 mm (height) 482.6 mm (width) 269.5 mm (depth) Figure 27 and Figure 28 illustrates the outline and inner structure of the ODF plug-in box respectively.

34

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 Components

FIGURE 27 OUTLINE OF ODF PLUG-IN BOX

1. Captive Fastener

2. Lug

3. Cable Outlet

4. Front Panel

FIGURE 28 INNER STRUCTURE OF ODF PLUG-IN BOX

1. Cable Outlet

2. Guide Rail

3. Front Panel

4. Adapter Board 5. ODF Board

FIGURE 29 POSITION AND NUMBER OF OPTICAL CONNECTORS ON ODF BOARD

The functions of components in ODF plug-in box are described in Table 27.

Confidential and Proprietary Information of ZTE CORPORATION

35

ZXMP M900 (V2.20) Hardware Manual

TABLE 27 STRUCTURES OF COMPONENTS IN ODF PLUG-IN BOX

Component Cable outlet

Function Entrance or outlet of the optical fiber cables. Loose the captive facilitate the layout screw the captive illustrated in Figure fastener on the front panel and open it to of cables. After that, close the front panel and fastener to seal the ODF plug-in box, as 27.

Front panel

Lug Captive fastener Guide rail Adapter board ODF board

The left lug and right lug at the rear of plug-in box, combining with captive fasteners on them, are used to fix the box in cabinet. Used to fix the front panel of the ODF plug-in box; Used to fix the ODF plug-in box in the cabinet.

The ODF board can be pulled out along the guide rail before laying optical fiber cables. The ODF board is fixed on it. 52 optical connectors can be installed on each ODF board at most for 52 optical fiber cables. The positions and numbers of optical connectors are as illustrated in Figure 29.

DCM Plug-in Box


The dispersion compensation should be considered for the line when the signal rate is above 10 Gbit/s. The dispersion compensation module (DCM) with four input/output interfaces can be installed in the DCM plug-in box. The DCM plug-in box is optional, and users can use it according to actual requirements. It is generally placed at the under layer of the subrack, and the location is as shown in Figure 4. Dimensions: 43.6 mm (height) 482.6 mm (width) 269.5 mm (depth) Figure 30 illustrates the structure of the DCM plug-in box.
FIGURE 30 STRUCTURE OF DCM PLUG-IN BOX

1. Dispersion Compensation Module

2. Lug

3. Captive Fastener

36

Confidential and Proprietary Information of ZTE CORPORATION

Components

4. Cable Outlet

5. Optical Connector

6. Front Panel

The functions of components in DCM plug-in box are described in Table 28.
TABLE 28 FUNCTIONS OF COMPONENTS OF DCM PLUG-IN BOX

Component Dispersion compensation module (DCM) Optical connector Cable outlet Front panel Lug Captive fastener

Function It is the core of DCM plug-in box. The compensation value of the module should be configured according to actual case. Optical fiber cables are connected to the module with optical connectors in the plug-in box. Located at the side panel of the plug-in box, it is a passage for optical cables in or out of the box. It is detachable, and should be detached before connecting optical cables. The left lug and right lug, combining with captive fasteners on them, are used to fix the plug-in box in the cabinet. Used to fix the front panel of the DCM plug-in box; Used to fix the DCM plug-in box in the cabinet.

Confidential and Proprietary Information of ZTE CORPORATION

37

ZXMP M900 (V2.20) Hardware Manual

This page is intentionally blank

38

Confidential and Proprietary Information of ZTE CORPORATION

Chapter

Boards
This chapter describes the functions, principles, structures and basic operations of all available boards provided for the ZXWM M900 equipment.

Overview
Table 29 lists all available boards provided for the ZXWM M900 equipment in terms of type and corresponding components or positions they can be plugged in.
TABLE 29 AVAIL ABLE BO ARDS FOR ZXWM M900

Board ID

Full Name

Applicable Position

Control and supervision boards NCP OSC OHP NCPF OSCF OHPF APSF PBX PWSB FCB NE Control Processor Optical Supervision Channel Overhead Processing Board NE Control Processor for Fast Ethernet Optical Supervision Channel for Fast Ethernet Overhead Processing Board for Fast Ethernet Automatic Protection Switching for Fast Ethernet Power Box Board Power Supervision Board Fan-Control Board Interface area of subrack Monitoring plug-in box Independent fan unit OA subrack

Optical transponder boards OTU OTUF OTU10G EOTU10G Optical Transponder Unit Optical Transponder Unit with FEC Optical Transponder Unit for 10 Gb/s Enhanced Optical Transponder Unit for 10 Gb/s OA/OTU subrack

Convergence boards

Confidential and Proprietary Information of ZTE CORPORATION

39

ZXMP M900 (V2.20) Hardware Manual

Board ID SRM42 SRM41 GEM2 GEMF GEM8 DSA DSAE DSAF SMU

Full Name Four 622 M/155 M SubRate Mux Board Four 2.5 G SubRate Mux Board Two Gigabit Ethernet Mux Board Gigabit Ethernet Mux Board with FEC Eight Gigabit Ethernet Mux Board Data Service Aggregation Board Data Service Aggregation Electrical Interface Board Data Service Aggregation with FEC SDH Multiplex Unit

Applicable Position

OA/OTU/TMUX subrack

Multiplex/demultiplex boards OCI OBM OMU VMUX ODU OAD WBU WSU WBM SDM Optical Channel Interleaver Optical Broadband Multiplexer Optical Multiplexing Unit Variable insertion loss Multiplexer Optical De-Multiplexing Unit Optical Add/Drop Board Wavelength Blocking Unit Wavelength Selective Unit Wavelength Blocking Multiplexing Supervisory Division Multiplexing Board OA/OTU subrack

Optical amplification boards DRA EOA Distributed Raman Amplifier Enhanced Optical Amplifier OA/OTU subrack

Power management boards LAC OWM OPM MCPD Line Attenuation Compensator Optical Wavelength Monitor Optical Performance Monitor Multi Channel Power Detector OA/OTU subrack

Protection boards OP OMCP OPMS OPCS Optical Protect Board Optical Multi-Channel Protection Optical Protect for Mux Section Optical Protect for Channel Section OA/OTU subrack

Clock board CA CSU Clock Assignment Cross_switch and Synchronous_clock Unit TMUX subrack

40

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Structure of Boards
The structure of boards for ZXWM M900 can be divided into four types according to the positions they can be placed in.

Structure of Boards in OA/OTU/TMUX Subrack


Figure 31 illustrates the structure of an OTU board.
FIGURE 31 STRUCTURE OF OTU BOARD

1. Front Panel

2. Spanner

3. PCB

Boards with this type of structure consist of front panel, spanners and PCB. Front panel: The front panel is made up of aluminium alloy. Indicators and necessary interfaces are located on it with corresponding silkscreen identifiers. The board name is also printed on the front panel. Spanner: The spanner is made of zinc alloy. The spanner can be self-locked with the spring plate on it. The main functions of the spanner are as follows. Facilitate pulling in/out the board due to the leverage of spanners; Lock the board in the subrack, and guarantee the reliability of connection between the board and backplane, and the electromagnetic compatibility (EMC) of the equipment. Contributing to the contact between the spanner and the subrack, electrostatic can be discharged while pulling out the board.

Confidential and Proprietary Information of ZTE CORPORATION

41

ZXMP M900 (V2.20) Hardware Manual

PCB The PCB is the principle part of board with the dimensions of 320 mm 210 mm. Its front is connected to the front panel. Connectors on its rear correspond to sockets on the backplane, through which the connection between the board and backplane is achieved. The metal shielding plate on the solder side of PCB guarantees the good EMC performance of the equipment. On the components side of the PCB, there is the version silkscreen with the format of the letter B followed by six Arabic numerals. The first two numerals indicate the release year, the second two indicate the release month, and the last two indicate the modification flag.

Board label Board label includes board indication label and board bar code label, which is not shown in Figure 31. Board indication label: It is pasted 2 mm below the silkscreen of board name on the board panel. Board indication label content includes line side (aggregate side) working frequencies for OTU boards/convergence boards. Board bar code label: Each board needs a board bar code label to indicate its bar code and type. Board bar code label is pasted close to the lower lever on the board panel. Board bar code label content includes the bar, bar code and GBOM material list number.

Structure of PBX Board


The PBX board is plugged in the slot in the common interface area of OA/OTU/TMUX subrack. It consists of the front panel, enclosure and PCB. Figure 32 illustrates the structure of the PBX board.
FIGURE 32 STRUCTURE OF PBX BOARD

Front

Rear

1. Front Panel

2. Enclosure

3. PCB

4. Installation Hole

Front panel: On the front panel, the indicators with silkscreen identifiers indicate the running status of the board. The board name is also printed on the front panel.

42

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Enclosure: It is used to enclose the PCB of the board. The PBX board can be fixed in the slot with the installation holes at both sides of the enclosure PCB: The PCB is the principle part of the PBX board with the dimensions of 90 mm 69 mm. Its front is connected to the front panel, while the rear is installed with the power interface and signal interface.

Structure of PWSB Board


The PWSB board is installed in the monitoring plug-in box. Figure 33 illustrates the structure of it.
FIGURE 33 STRUCTURE OF PWSB BOARD

1. Monitoring Plug-in Box (without top cover) 2. PCB

3. Front Panel

Monitoring plug-in box It is used to enclose the PCB of PWSB board. Refer to the section Monitoring Plug-in Box for detailed description.

PCB The PCB is the principle part of PWSB board with the dimensions of 134 mm 160 mm. It connected to the front panel.

Front panel Various interfaces and indicators are located on the front panel of PWSB board with corresponding silkscreen identifiers.

Structure of FCB Board


The FCB board is installed in the independent fan unit as shown in Figure 22. It is a PCB with the dimensions of 115 mm 45 mm. Figure 34 illustrates the structure of the FCB board.

Confidential and Proprietary Information of ZTE CORPORATION

43

ZXMP M900 (V2.20) Hardware Manual

FIGURE 34 STRUCTURE OF FCB BOARD

Optical Transponder Boards


Board ID OTU OTUF OTU10G ENOTU10G Full Name Optical Transponder Unit Optical Transponder Unit with FEC Optical Transponder Unit for 10 Gb/s Enhanced Optical Transponder Unit for 10 Gb/s OA/OTU subrack Applicable Position

OTU Board
Functions
The optical/electrical/optical conversion mode is adopted to implement the wavelength conversion and data regeneration in the optical transponder unit (OTU) board. It can be divided into two types, terminal OTU and regenerator OTU (OTUG). OTU (Terminal) It converts wavelengths of double-channel multi-service signals at the rate of STM-16 (2.5Gbit/s) or below. The terminal OTU can be divided into transmitter OTU (OTUT), receiver OTU (OTUR) and single-channel bidirectional OTU. Optical interfaces of the OTU board locate at the line side and client side. The line side, carrying G.692 signals with wavelength information, supports fixed wavelength lasers and tunable wavelength lasers. The wavelength tunable function covers the low-cost 4/8-channel continuous wavelengths in C-band as well as the whole C-band. The channel spacing is 100 GHz for 4-channel, while it is 50 GHz for 8-channel. The carries client signals, including STM-1/STM-4/STM-16/GE optical signals or continuous-rate services signals.

44

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

OTU (Regenerator, OTUG) It implements the reshaping, timing extraction and data regeneration for double-channel line optical signals. All optical interfaces of OTUG locate at the line side. Both the receiving and transmitting optical signals at the line side meet the requirements of ITU-T G.692. And the optical signals can be STM-1/STM-4/STM-16/GE optical signals or continuous-rate service signals. OTUG board also supports fixed lasers and tunable lasers. Moreover, it can be used as regeneration board for terminal OTU board.

The terminal OTU and regenerator OTU feature the characteristics when continuous-rate services are accessed.

following

Any optical signals in compliance with ITU-T G.957 can be accessed at the client side within the rate range 12.3 Mbit/s-2.7 Gbit/s, such as STM-1/STM-4/STM-16/GE optical signals, enterprise system connection (ESCON) optical signals, fiber distributed data interface (FDDI) optical signals, fiber channel (FC) signals, digital video broadcasting (DVB) optical signals and high definition TV (HDTV) optical signals.The type of access service is configured through the network management system ZXONM E300, which provides the following three service configuration methods. Automatic Lock of Service Type: OTU board itself detects the rate of accessed service signal automatically and try to lock the service signal. Manual Lock of Service Type: Lock the rate of service signal accessed to the port by specifying the service type in the EMS. Each kind of service corresponds to a service rate. Manual Lock of Service Rate: Lock the service signal by specifying the rate of accessed service in the EMS. The precision of rate specified in the EMS is 100 ppm. That means at least four effective digits of the rate input in the EMS should match the actual rate; or else the service signal can not be locked.

Terminal OTU and OTUG board will report LOL (Loss of Lock) alarm message if the accessed service signal is out of lock. The OTU has the function of checking B1 and J0 byte in STM-4/STM-16 signals, and error packets in GE signals. The OTU supports integrated wavelength supervision sub-systems with the channel spacing 50 GHz. For detailed description of integrated wavelength supervision sub-system, please refer to Appendix C. The OTU supports client side loopback and line side loopback to facilitate the fault localization.

Operating Principle
Figure 35 illustrates the operating principle of terminal OTU board (single-channel bidirectional OTU board for example).

Confidential and Proprietary Information of ZTE CORPORATION

45

ZXMP M900 (V2.20) Hardware Manual

FIGURE 35 OPERATING PRINCIPLE OF TERMINAL OTU BOARD

G.957 GbE

Optical Receiving (O/E)

Specific Wavelength Optical Transmitting (E/O)

G.692

Performance and Overhead Supervision Unit

G.957 GbE

Non-Specific Wavelength Optical Transmitting (E/O)

Optical Receiving (O/E)

G.692

Control and Communication Unit

Figure 36 illustrates the operating principle of regenerator OTU board.


FIGURE 36 OPERATING PRINCIPLE OF REGENERATOR OTU BOARD

G.692

Optical Receiving (O/E)

Specific Wavelength Optical Transmitting (E/O)

G.692

Performance and Overhead Supervision Unit

G.692

Specific Wavelength Optical Transmitting (E/O)

Optical Receiving (O/E)

G.692

Control and Communication Unit

The OTU board consists of optical receiving modules, optical transmitting modules, performance and overhead supervision unit, and control and communication unit. Optical receiving module

46

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

It transfers the received optical signals into electrical signals through optical/electrical (O/E) conversion. Optical transmitting module There are two kinds of optical transmitting modules: Specific wavelength optical transmitting module: it converts electrical signals into optical signals in compliance with ITU-T G.692. Non-specific wavelength optical transmitting module: it converts electrical signals into optical signals without special requirements for wavelength.

Note: Only the regenerator OTU (OTUR) and single-channel bidirectional OTU board has the non-specific wavelength optical transmitting module.

Performance and overhead supervision unit It processes performance and overhead supervision information from optical receiving modules and transmitting modules, and then transmits them to the control and communication unit.

Control and communication unit It receives monitoring information from each modules and supervision information from the performance and overhead supervision unit, and then forwards them to the EMS. At the same time, it receives the commands from the EMS to control output wavelengths, power and overheads.

Front Panel: Interfaces and Indicators


The front panel of OTU board is illustrated in Figure 37.

Confidential and Proprietary Information of ZTE CORPORATION

47

ZXMP M900 (V2.20) Hardware Manual

FIGURE 37 FRONT P ANEL OF OTU BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

Table 30 describes the front panel and related information for basic operations.
TABLE 30 FRONT P ANEL DESCRIPTIONS OF OTU BOARD AND REL ATED OPERATION INFORM ATION

Board Type Item Board ID Board Type Label Working Frequency Label Bar Code Label NO M ALM Laser Warning Sign

OTU Transmitter

OTU Receiver

Single-Path Bidirectional OTU OTU

OTU Regenerator

Frequency label is pasted below the board ID, which indicates board working frequency. Board bar code label is pasted close to the lower spanner on the board panel. It consists of bar code information and GBOM information, which indicate board bar code and board type respectively. Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes.

Indicator

48

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Type Item IN1 OUT 1 IN2 OUT 2 Number of Occupied Slots Laser class sign Slots for OTU Board

OTU Transmitter Client input interface 1 Line output interface 1 Client input interface Line output interface 2 1

OTU Receiver Line input interface 1 Client output interface 1 Line input interface 2 Client output interface 2 1

Single-Path Bidirectional OTU Client interface Line interface Line interface Client interface 1 input

OTU Regenerator Line 1 interface Line 1 interface Line 2 interface Line 2 interface 1 input

output

output

Optical Interface (LC/PC)

input

input

output

output

Indicates that the laser class of OTU board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8


Operation Precautions

Avoid damaging the fiber pigtail plugging/unplugging the board.

interface

while

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The label is pasted at the side of the board identification.

Table 31 lists the OTU board status and corresponding status of indicators.
TABLE 31 RELATIONS BETWEEN OTU BOARD AND INDICATOR STATUS

Working Status The board configuration. is waiting for

Indicator Status NOM (Green) ALM (Red)

The red indicator and the green indicator flash slowly and alternately. Flashing slowly and regularly Flashing slowly and regularly ON Off On Flashing slowly regularly and

The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. The board is in the status of initialization. The board is waiting for download. The board is in download status.

The red indicator and the green indicator flash quickly at the same time. The red indicator and the green indicator flash slowly at the same time.

Confidential and Proprietary Information of ZTE CORPORATION

49

ZXMP M900 (V2.20) Hardware Manual

Performance and Alarm Messages


The performance, alarm and event messages of the OTU board are listed in Table 32.
T AB L E 3 2 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OTU B O AR D

Type

Item Output optical power Input optical power Laser bias current Laser TEC current Laser temperature offset 15-min B1 bit error count 15-min ES 15-min SES 15-min UAS

Remark Only for SDH service Only for SDH service Only for SDH service Only for SDH service Only for SDH service Only for GE service Only for GE service Only for GE service Only for GE service Only for GE service Only for GE service Only for GE service Only for GE service Only for SDH service Only for SDH service Only for GE service Only for SDH service -

Performances

15-min BER 15-min received packets count Total received byte count 15-min received error packet count 15-min received error packet ratio 15-min 8B/10B coding violation (CV) count 15-min 8B/10B CV ES 15-min 8B/10B CV SES 15-min 8B/10B CV UAS Board environment temperature

Alarms

Environment temperature alarm High input power alarm Low input power alarm No input power alarm Lost of frame alarm (LOF) Signal degradation alarm (SD) Received error packet ratio over-threshold alarm J0 trace mismatch alarm High output power alarm Low output power alarm No output power alarm Laser over-current alarm Laser temperature offset over-threshold alarm

50

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Type

Item Unavailable signal alarm Lost of signal alarm (LOS) Lost of lock alarm (LOL) Receiving signal MS_AIS 15-min/24-hour B1 bit error over-threshold alarm 15-min/24-hour ES over-threshold alarm 15-min/24-hour SES over-threshold alarm 15-min/24-hour UAS over-threshold alarm 15-min/24-hour 8B/10B CV count over-threshold alarm 15-min/24-hour 8B/10B CV second over-threshold alarm 15-min/24-hour 8B/10B severely CV second over-threshold alarm 15-min/24-hour 8B/10B CV UAS over-threshold alarm Laser end-of-life alarm Laser fault alarm Cooler over-current alarm Laser shut-down automatically

Remark Only for SDH service Only continuous-rate service fro

Only for SDH service Only for SDH service Only for SDH service Only for SDH service Only for SDH service Only for GE service Only for GE service Only for GE service Only for GE service -

Events

Laser start

up automatically

Laser APS shut-down forcibly Laser APS start up forcibly

OTUF Board
Functions
OTUF (Optical Transponder Unit with FEC) is a kind of OTU board provided with the FEC (Forward Error Correction) specified in ITU-T G.709 as well as the overhead processing function. It uses the O/E/O conversion mode to realize the wavelength conversion and data regeneration. In terms of actual application, OTUF board is classified into terminal OTUF board and regenerator OTUF board (OTUFG). Terminal OTUF Terminal OTUF board implements the wavelength conversion for single-channel bidirectional service signals at the rate of STM-16 (2.5Gbit/s) or below.

Confidential and Proprietary Information of ZTE CORPORATION

51

ZXMP M900 (V2.20) Hardware Manual

Terminal OTUF board supports the access of STM-1, STM-4, STM-16 or GE signals at client side. Its line-side optical signals meet the wavelength requirement of ITU-T G.692. In addition, terminal OTUF board provides the overhead processing and FEC functions on the line side. Similar to terminal OTU board, either fixed lasers or tunable lasers can be used at the line side of terminal OTUF board. Tunable lasers applied in OTUF board supports the tuning of 4/8 channels of continuous wavelengths in C band. The channel spacing is 100 GHz when 4 channels of wavelengths are tuned; while the spacing is 50 GHz when 8 channels are tuned. The terminal OTUF board also supports the tuning of 80-channel of wavelength in the whole C-band. Regenerator OTUF (OTUFG) OTUFG implements the reshaping, timing extraction, data regeneration, and FEC encoding/decoding for single-channel bidirectional or unidirectional line optical signals. Single-channel unidirectional OTUFG board Both received and transmitted optical signals of the single-channel unidirectional OTUFG board meet the requirement of ITU-T G.692 and G.709. Single-channel bidirectional OTUFG board In one optical direction, the single-channel bidirectional OTUFG board performs the FEC encoding for the input ITU-T G.692 optical signal, and outputs the encoded optical signal meeting the requirement of ITU-T G.692 and G.709. In the other optical direction, the board performs the FEC decoding for the input optical signal complying with ITU-T G.692 and G.709, and outputs the decoded optical signal meeting the requirement of ITU-T G.692. OTUFG board also supports fixed lasers and tunable lasers. The tune range of tunable laser is the same as that of terminal OTUF board. In addition, OTUFG board can be used as the regenerator board of terminal OTUF board and GEMF board. Both the terminal OTUF board and the OTUFG board provide the following additional functions: Check B1, B2 and J0 bytes for SDH signals, and checks error packets for GE signals. Supports section monitoring (SM) and path monitoring (PM) for OTN signals. Supports the function of error correction and report. Supports Auto Power SwitchDown (APSD) and tunable wavelength. Supports the application in a centralized wavelength supervision subsystem. For detailed information about the centralized wavelength supervision subsystem, please refer to Appendix C in this manual.

52

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Supports both client-side loopback and line-side loopback for the fault localization.

Operating Principle
Taking the single-channel bidirectional terminal OTUF board as example, Figure 38 illustrates its operating principle.
FIGURE 38 OPERATING PRINCIPLE OF TERMINAL OTUF BOARD
G.692 G.709

G.957 GbE

Optical Receiving (O/E)

Specific Wavelength Optical Transmitting (E/O)

FEC Framer

G.957 GbE

Non-Specific Wavelength Optical Transmitting (E/O)

Optical Receiving (O/E)

G.692 G.709

Control and Communication Unit

Figure 39 illustrates the operating principle of OTUFG board, including single-channel bidirectional OTUF board and single-channel unidirectional OTUF board.
FIGURE 39 OPERATING PRINCIPLE OF REGENERATOR OTUF BOARD
G.692 G.709 G.692 G.709

Optical Receiving (O/E)

Specific Wavelength Optical Transmitting (E/O)

FEC Framer

Control and Communication Unit

Single-Channel Bidirectional OTUF Board

Confidential and Proprietary Information of ZTE CORPORATION

53

ZXMP M900 (V2.20) Hardware Manual

G.692

Optical Receiving (O/E)

Specific Wavelength Optical Transmitting (E/O)

G.692 G.709

FEC Framer

G.692

Specific Wavelength Optical Transmitting (E/O)

Optical Receiving (O/E)

G.692 G.709

Control and Communication Unit

Single-Channel Unidirectional OTUFG Board

The OTUF board consists of optical receiving modules, optical transmitting modules, FEC framer, and the control and communication unit. Optical receiving module It transfers the received optical signals into electrical signals through O/E conversion. Optical transmitting module There are two kinds of optical transmitting modules: Specific wavelength optical transmitting module: It converts the ITU-T G.709 electrical signal received from the FEC framer into the optical signal complying with both ITU-T G.692 and G.709. Non-specific wavelength optical transmitting module: It converts the electrical signal received from the FEC framer into optical signal without special requirement for wavelength, and then outputs the optical signal to user equipment.

FEC framer It implements the FEC coding and decoding of signals. The FEC function can be configured online in the EMS. In addition, the FEC framer can process performance and overhead supervision information, and transmit supervision data and overheads to the control and communication unit.

Control and communication unit It receives monitoring information from each module and supervision information from the performance and overhead supervision unit, and then reports them to the EMS. On the other hand, it receives the commands from the EMS for controlling output wavelengths, power and overheads.

54

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Front Panel: Interfaces and Indicators


The front panel of single-channel bidirectional terminal OTUF board is same as that of the single-channel bidirectional OTUFG board, as illustrated in Figure 40.
FIGURE 40 FRONT P ANEL OF OTUF BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

There is only one pair of optical interface (IN/OUT) on the front panel of the OTUFG board. Table 33 describes the front panel and related information for basic operations of the OTUF board.
TABLE 33 FRONT P ANEL DESCRIPTION OF OTUF BOARD AND REL ATED OPERATION INFORM ATION

Board Type Item Board ID Label [Note 1] Indicator NOM

OTUF OTU F

Single-Channel Bidirectional OTUFG

Single-Channel Unidirectional OTUFG

FG

FG

Running indicator, green

Confidential and Proprietary Information of ZTE CORPORATION

55

ZXMP M900 (V2.20) Hardware Manual

Board Type Item ALM IN1 OUT1 Optical interface (LC/PC connector) IN2 OUT2 IN OUT Laser warning sign Laser class sign Number of occupied slots Slots for OTUF board

OTUF

Single-Channel Bidirectional OTUFG

Single-Channel Unidirectional OTUFG

Alarm indicator, red Client input 1 Line output 1 Line input 2 Client output 2 Line 1 input (without FEC) Line 1 output (with FEC) Line 2 input (with FEC) Line 2 output (without FEC) Line input (with FEC) Line output (with FEC)

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OTUF board is CLASS 1 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging fiber pigtail connectors while plugging/unplugging the board. Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Operation precautions

Note: 1. If optical signals at both sides of the line have the FEC function, the single-channel unidirectional OTUFG board should be used as the regenerator board. If only optical signals at one side of the line have the FEC function, the double-channel OTUFG board should be used as the regenerator board. The rates of butting optical interfaces should be matching, or else the service transmission will be interrupted.

2.

The relations between the OTUF board status and corresponding indicators status are same as that of the OTU board. Please refer to Table 31 for detailed description.

56

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Performance and Alarm Messages


The performance, alarm and event information of the OTUF board are listed in Table 34.
T AB L E 3 4 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OTUF B O AR D

Type

Item Output optical power Input optical power Laser bias current

Remark Detection requirement depends on the board configuration Detection requirement depends on the board configuration Detection requirement depends on the board configuration Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for GE traffic Only for GE traffic Only for GE traffic Only for GE traffic Only for GE traffic Only for GE traffic Only for GE traffic k=1 k=1 -

Laser TEC current Laser temperature offset MZ modulation bias power B1 bit error B2 bit error Errored second Severely errored second Down time Performance Bit error rate Received packet Received error packet Received error packet ratio 8B/10B coding violation 8B/10B error second 8B/10B severely error second 8B/10B down time FEC uncorrective frame FEC corrective bit error FEC corrective 0 bit error FEC corrective 1 bit error Bit error ratio before FEC Bit error ratio after FEC OTUk-SM-BIP8 bit error ODUk-SM-BIP8 bit error Board environment temperature

Confidential and Proprietary Information of ZTE CORPORATION

57

ZXMP M900 (V2.20) Hardware Manual

Type Alarm

Item Environment temperature alarm High input power alarm Low input power alarm No input power alarm Lost of frame alarm (LOF) Signal degradation alarm (SD) Signal unavailability alarm J0 TIM alarm LOS alarm 15-min/24-hour B1 bit error over-threshold alarm 15-min/24-hour B2 bit error over-threshold alarm 15-min/24-hour ES over-threshold alarm 15-min/24-hour SES over-threshold alarm 15-min/24-hour UAS over-threshold alarm Receiving signal MS_AIS alarm Alignment loss alarm 15-min/24-hour received error packet 15-min/24-hour 8B/10B coding violation 15-min/24-hour 8B/10B error second 15-min/24-hour 8B/10B severely error second OTUk J0 TIM alarm 15-min/24-hour OTUk BIP8 error over-threshold alarm OTUk LOF alarm OTUk loss of multi-frame alarm OTUk layer SM section backward defect indication (BDI) OTUk layer SM section backward error indication (BEI) OTUk layer SM section alignment error (BIAE) backward incoming

Remark Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for GE traffic Only for GE traffic Only for GE traffic Only for GE traffic Only for GE traffic k=1 k=1 k=1 k=1 k=1 k=1 k=1 k=1 k=1 k=1 k=1 k=1 k=1

OTUk layer SM section incoming alignment error (IAE) ODUk layer PM section TIM alarm ODUk layer PM section backward defect indication (BDI) ODUk layer PM section backward error indication (BEI) ODUk AIS alarm ODUk LCK alarm

58

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Type

Item ODUk OCI alarm OTUk PT TIM alarm No output power alarm Low output power alarm High output power alarm Laser temperature offset over-threshold alarm Laser over-current alarm Cooler over-current alarm MZ modulated laser power over-threshold alarm Laser end-of-life alarm Laser failure alarm MCU reset Laser shut-down automatically

Remark k=1 k=1 Detection requirement depends on the board configuration -

Event

Laser startup automatically Laser APS shut-down forcibly Laser APS startup forcibly Board configuration is faulty

OTU10G Board
Functions
OTU10G (Optical Transponder Unit for 10 Gbit/s) uses the O/E/O conversion mode to realize the wavelength conversion and data regeneration. In addition, the OTU10G board supports the FEC or advanced FEC (AFEC) coding/decoding, and the G.709 overhead processing. OTU10G board is classified into two types in terms of actual application: single-channel bidirectional OTU10G (i.e. terminal OTU10G board), single-channel unidirectional regenerator OTU10G (OTU10G G). Single-channel bidirectional terminal OTU10G It implements wavelength conversion for single-channel bidirectional optical signals at the rate of STM-64 (10 Gbit/s) or 10 GE (10.3125 Gbit/s). The client side supports the access of optical signals at the rate of STM-64 or 10 GE. Optical signals at the line side meet the requirements of ITU-T G.692. In addition, the line side supports the FEC or AFEC function, which is configured on the EMS.

Confidential and Proprietary Information of ZTE CORPORATION

59

ZXMP M900 (V2.20) Hardware Manual

FEC: The use of FEC in compliance with ITU-T G.975/G.709 improves the OSNR (Optical Signal-to-Noise Ratio) by about 5 dB to 6 dB equivalently. AFEC: AFEC is an improved FEC algorithm which can improve the OSNR by about 7 dB to 9 dB equivalently.

For STM-64 services, the rate after coding is 10.709 Gbit/s. For 10 GE services, the rate after coding is 11.1 Gbit/s. Single-channel Unidirectional Regenerator OTU10G (OTU10G G) OTU10G G board implements the reshaping, timing extraction and data regeneration for single-channel line optical signals. Both the line-side optical received and transmitted signals comply with ITU-T G.692. The FEC or AFEC function (G.975/G.709) is also provided. The rate of line optical signals is 10.709 Gbit/s (STM-64) or 11.1 Gbit/s (10GE). OTU10G G board with FEC function can be used as the regenerator board for SRM41 board, GEM8 board or terminal OTU10G board. OTU10G G board with AFEC function can be used as the regenerator board for GEM8 board or terminal OTU10G board with the same AFEC technology.

The OTU10G board has the function of checking B1, B2 and J0 byte for SDH signals, and error packets for 10GE signals. The overhead checking and processing function in compliance with ITU-T G.709 is provided. For single-channel unidirectional OTU10G G, the electrical return-to-zero (ERZ) technology is adopted to improve the tolerance of system to the OSNR, and thus extend longer transmission distance. The line side supports fixed wavelength lasers and tunable wavelength lasers. Tunable lasers supports the tuning of 40/80 channels of wavelengths in C band. The channel spacing is 100 GHz when 40 channels of wavelengths are tuned; while the spacing is 50 GHz when 80 channels are tuned. The OTU10G board supports integrated wavelength sub-systems with channel spacing at 50 GHz. supervision

The OTU10G board supports client side loopback and line side loopback to facilitate the fault locating.

Operating Principle
The operating principles of terminal OTU10G and regenerator OTU10G boards are illustrated in Figure 41 and Figure 42 respectively. For the description of each module, please refer to the section OTUF board. The signal definitions are illustrated as shown in

60

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 41 OPERATING PRINCIPLE OF SINGLE-P ATH BIDIRECTIONAL OTU10G


G.957 10GbE

Optical Receiving (O/E)

Specific Wavelength Optical Transmitting (E/O)

G.692 G.709 or AFEC

FEC Framer

G.957 10GbE

Non-Specific Wavelength Optical Transmitting (E/O)

Optical Receiving (O/E)

G.692 G.709 or AFEC

Control and Communication Unit

FIGURE 42 OPERATING PRINCIPLE OF SINGLE-CHANNEL UNIDIRECTIONAL OTU10G G

Confidential and Proprietary Information of ZTE CORPORATION

61

ZXMP M900 (V2.20) Hardware Manual

Front Panel: Interfaces and Indicators


Take single-channel bidirectional terminal OTU10G board as example. Figure 43 illustrates the front panel of it.
FIGURE 43 FRONT P ANEL OF SINGLE-P ATH BIDIRECTIONAL OTU10G BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

For single-channel unidirectional OTU10G G board, there is only one pair of optical interface (IN/OUT) on the front panel (not illustrated).

62

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Table 35 describes the front panel and related information for basic operations of the OTU10G board.
TABLE 35 FRONT P ANEL DESCRIPTIONS OF OTU10G BOARD AND RELATED OPERATION INFORM ATION

Board Type Item Board ID Label [Note 1] Indicator


[Note 2]

Single-Channel Bidirectional Terminal OTU10G OTU10G -

Single-Channel Unidirectional Regenerator OTU10G OTU10G G

NOM ALM IN1 OUT1

Running indicator, green Alarm indicator, red Client input interface Line output interface Line input interface Client output interface 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Line input interface Line output interface 1 1

Optical Interface (LC/PC)

IN2 OUT2 IN OUT

Number of Occupied Slots Slots for OTU10G Board Laser Warning Sign Laser Class Sign Operation Precautions

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates the classification of OTU10G is CLASS 1

Avoid damaging the fiber pigtail plugging/unplugging the board.

interface

while

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: 1. 2. The label is pasted at the side of the board identification. The relations between the OTU10G board status and corresponding indicators status are same as that of the OTU board. Please refer to Table 31 for detailed description.

Confidential and Proprietary Information of ZTE CORPORATION

63

ZXMP M900 (V2.20) Hardware Manual

Performance and Alarm Messages


The performance, alarm and event information of the OTU10G board are listed in Table 36.
T AB L E 3 6 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F O T U 1 0 G B O AR D

Type

Item Board environment temperature Output optical power Input optical power Laser bias current Laser temperature offset 15-min B1 bit error 15-min B2 bit error 15-min ES 15-min SES

Remark Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for 10 GE traffic Only for 10 GE traffic Only for 10 GE traffic k=2 -

Performance

15-min UAS 15-min BER 15-min received packet count 15-min received error packet count 15-min received error packet ratio 15-min OTUk BIP8 error count FEC corrected BE count FEC corrected 0 error count FEC corrected 1 error count After-FEC BER FEC uncorrectable frame count

Alarm

Board environment temperature alarm No input optical power alarm Low input optical power alarm High input optical power alarm LOF alarm SD alarm UAS alarm J0 TIM alarm LOS alarm 15-min/24-hour B1 error over-threshold alarm 15-min/24-hour B2 error over-threshold alarm

Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic

64

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Type

Item 15-min/24-hour ES over-threshold alarm 15-min/24-hour SES over-threshold alarm 15-min/24-hour UAS over-threshold alarm Receiving signal MS_AIS 15-min received error packet over-threshold alarm OTUk J0 TIM alarm 15-min/24-hour OTUk BIP8 error over-threshold alarm OTUk LOF alarm OTUk loss of multi-frame alarm

Remark Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for 10 GE traffic k=2 k=2 k=2 k=2 k=2 k=2 k=2 -

Alarm

15-min/24-hour after-FEC ER over-threshold alarm 15-min/24-hour before-FEC ER over-threshold alarm 15-min/24-hour OTUk-SM over-threshold alarm No output optical power alarm Low output optical power alarm High output optical power alarm Laser current over-threshold alarm Laser temperature offset over-threshold alarm Laser end-of-life alarm Laser fault alarm Laser shut-down automatically BIP8 UAS

Event

Laser startup automatically Laser APS shut-down forcibly Laser APS startup forcibly

EOTU10G Board
Functions
EOTU10G (Enhanced Optical Transponder Unit for 10 Gbit/s) board uses the O/E/O conversion mode to realize the wavelength conversion and data regeneration. In addition, OTU10G board, complying with ITU-T G.709, supports FEC or AFEC (Advanced FEC) encoding/decoding and the processing of overhead.

Confidential and Proprietary Information of ZTE CORPORATION

65

ZXMP M900 (V2.20) Hardware Manual

EOTU10G board is classified into two types in terms of actual application: single-channel bidirectional EOTU10G (i.e. terminal EOTU10G board) and regenerator EOTU10G (EOTU10G G) including single-channel bidirectional EOTU10G G and single-channel unidirectional EOTU10G G.

Single-channel bidirectional terminal EOTU10G It implements the wavelength conversion for single-channel bidirectional STM-64 optical signal (9.953 Gbit/s), OTU2 (10.709 Gbit/s) or 10GE optical signal (10.3125 Gbit/s). Single-channel bidirectional OTU10G board supports the access of STM-64 and 10GE optical signal at its client side. The optical signals at its line side meet the requirement of ITU-T G.692. In addition, the line side supports the FEC or AFEC function, which is configured on the EMS. FEC: The use of FEC in compliance with ITU-T G.975/G.709 improves the OSNR (Optical Signal-to-Noise Ratio) by about 5 dB to 6 dB equivalently. AFEC: AFEC is an improved FEC algorithm which can improve the OSNR by about 7 dB to 9 dB equivalently. For STM-64 signal accessed at client side, the signal rate after AFEC encoding is 10.709 Gbit/s. For 10GE signal accessed at client side, the signal rate after AFEC encoding is 11.1 Gbit/s.

Regenerator EOTU10G (EOTU10G G) EOTU10G G board implements the reshaping, timing extraction and data regeneration for single-channel line optical signal. Both the line-side optical received and optical launched signals comply with ITU-T G.692. The rate of line optical signals is 10.709 Gbit/s (STM-64) or 11.1 Gbit/s (10G). Single-channel bidirectional EOTU10G G: The line-side input interface 1 only supports FEC function, while line-side input interface 2 supports both FEC and AFEC function. EOTU10G G board with FEC or AFEC function can be used as the regenerator board for SRM41/OTN board or terminal EOTU10G board with the same FEC or AFEC technology. Single-channel unidirectional EOTU10G G: EOTU10G G board with FEC or AFEC function can be used as the regenerator board for SRM41/OTN board or terminal EOTU10G board with the same FEC or AFEC technology.

Both the terminal OTU10G board and the OTU10G G board provide the following additional functions:

Checks B1, B2 and J0 bytes for SDH signals, and checks error packets for 10GE signals. Supports the overhead checking and processing function in compliance with ITU-T G.709. Adopts the Electrical Returen-to-Zero (ERZ) technology to improve the system tolerance to OSNR, and thus entend the transmission distance.

66

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Supports the application of either fixed lasers or tunable lasers. Tunable lasers applied at the line side of EOTU10G board supports the tuning of 40/80 channels of wavelengths in C band. The channel spacing is 100 GHz when 40 channels of wavelengths are tuned. while the spacing is 50 GHz when 80 channels are tuned. Supports the application in a centralized wavelength supervision subsystem with channel spacing at 50 GHz. For detailed information about the centralized wavelength supervision subsystem, please refer to Appendix C in this manual. Supports client-side loopback and line-side loopback for the fault localization.

Operating Principle
The operating principles of terminal EOTU10G and regenerator EOTU10G boards are illustrated in Figure 44 and Figure 45. The signal definitions are illustrated as shown in Table 37.
FIGURE 44 EOTU10G OPERATING PRINCIPLE OF SINGLE-CHANNEL BIDIRECTIONAL

STM-64 10GE OTU2

Optical Receiving (O/E)

Specific Wavelength Optical Transmitting (E/O)

OTU2 OTU2 (AFEC) 10GE OTU2 10GE OTU2 (AFEC)

FEC Framer

STM64 10GE OTU2

Non-Specific Wavelength Optical Transmitting (E/O)

Optical Receiving (O/E)

OTU2 OTU2 (AFEC) 10GE OTU2 10GE OTU2 (AFEC)

Control and Communication Unit

Confidential and Proprietary Information of ZTE CORPORATION

67

ZXMP M900 (V2.20) Hardware Manual

FIGURE 45

OPERATING PRINCIPLE OF REGENERATOR EOTU10G


OTU2 OTU2 AFEC 10GE OTU2 10GE OTU2 AFEC)

OTU2 10GE OTU2

Optical Receiving O/E

Specific Wavelength Optical Transmitting E/O

FEC Framer

OTU2 OTU2 (AFEC) 10GE OTU2 10GE OTU2 (AFEC)

Specific Wavelength Optical Transmitting E/O

Optical Receiving O/E

OTU2 OTU2

AFEC

10GE OTU2 10GE OTU2 AFEC)

Control and Communication Unit

Single-channel bidirectional EOTU10G G

Single-channel bidirectional EOTU10G G

TABLE 37 SIGNAL DEFINITION OF EOUT10G BOARD

Signal STM-64 10GE OTU2 OTU2AFEC 10GE OTU2

RateGbit/s 9.95328 10.3125 10.709 10.709 11.1

Signal Frame G.707 10GE LAN with 64/66B coding G.709 G.709 G.709 G.709

FEC Algorithm FEC AFEC FEC AFEC

Optical Interface Standard G.957/G.691 IEEE 802.3ae G.691/G.692 G.692 G.692 G.692

10GE OTU2 AFEC 11.1

EOTU10G board consists of optical receiving modules, optical transmitting modules, FEC framer and the control and communication unit.

68

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Optical Receiving Module It converts received optical signals into electrical signals through O/E conversion.

Optical Transmitting Module It can be classified into specific wavelength transmitting optical module and non-specific wavelength transmitting optical module. Specific Wavelength Optical Transmitting Module: It converts electrical signal in compliance with ITU-T G.709 from FEC framer into optical signal that meets the requirement of ITU-T G.692 and ITU-T G.709. Non-Specific Wavelength Optical Transmitting Module: It converts electrical signal from FEC framer into optical signal that has no special requirements for wavelength and then outputs the optical signal to user equipment.

FEC Framer It supports FEC or AFEC coding/decoding/coding and decoding. FEC function can be configured on EMS. In addition, it also supports performance monitoring and overhead processing function, and then input performance monitoring data and overhead bytes to the control and communication unit. For single-channel bidirectional terminal EOTU10G and single-channel unidirectional EOTU10G G, line-side interface supports FEC or AFEC function. The line-side interface 1 of single-channel bidirectional OTU10G G only supports FEC, while interface 2 supports FEC or AFEC.

Control and Communication Unit It receives the monitoring information from each module and the performance and overhead monitoring unit, and then reports them to the EMS. On the other hand, it receives the commands from the EMS for controlling the output wavelengths, optical power and overheads in the board.

Front Panel: Interfaces and Indicators


Figure 43 shows the front panel of the single-channel bidirectional EOTU10G board.

Confidential and Proprietary Information of ZTE CORPORATION

69

ZXMP M900 (V2.20) Hardware Manual

FIGURE 46 BOARD

FRONT PANEL OF SINGLE-CHANNEL BIDIRECTIONAL EOTU10G

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

The front panel of EOTU10G G board is similar to that shown in Figure 43 except that EOTU10G G board has only one pair of optical interfaces (IN/OUT) on its front panel. Table 38 describes the front panel and related information for basic operations of EOTU10G board.
TABLE 38 DESCRIPTION OF EOTU10G BOARDS FRONT PANEL AND RELATED OPERATION INFORMATION

Board Type Item

Single-Channel Bidirectional EOTU10G

Single-Channel Regenerator EOTU10G Single-channel bidirectional EOTU10G G Single-channel unidirectional EOTU10G G

Board ID Label [Note 1] Indicator


[Note 2]

EOTU10G T/R NOM ALM IN1 Running indicator, green Alarm indicator, red Client input interface Line interface input G

Optical Interface

70

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

(LC/PC)

OUT1 IN2 OUT2 IN OUT

Line output interface Line input interface Client output interface 1 All slots in OTU subrack

Line interface Line interface Line interface 1

output input output

Line interface input

Line output interface 1

Number of Occupied Slots Slots for OTU10G Board Laser Warning Sign Laser Class Sign Operation Precautions

Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates the classification of EOTU10G is CLASS 1

Avoid damaging the fiber pigtail plugging/unplugging the board.

interface

while

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The label is sticked at the side of the board identification.

The relations between the working status and corresponding indicator status of EOTU10G board are same as those of OTU board. Please refer to Table 31 for detailed description.

Performance and Alarm Messages


The performance, alarm and event messages of the OTU10G board are listed in Table 39.
TABLE 39 PERFORMANCE, ALARM AND EVENT MESSAGES OF OTU10G BOARD

Type Performance

Item Board environment temperature Output optical power Input optical power Laser bias current

Remark -

Confidential and Proprietary Information of ZTE CORPORATION

71

ZXMP M900 (V2.20) Hardware Manual

Type

Item

Remark Detection requirement depends on the board configuration Detection requirement depends on the board configuration

Laser temperature offset

MZ modulation bias power

High input optical power over-threshold 15-min B1 error count 15-min B2 error count 15-min ES 15-min SES 15-min UAS 15-min BER 15-min received packet count 15-min received error packet count 15-min received error packet ratio 15-min received PAUSE frame 15-min received byte 15-min OTUk SM BIP8 error count 15-min ODUk PM BIP8 error count 15-min OTUk SM BIP8 ES 15-min OTUk SM BIP8 SES FEC corrected BE count FEC corrected 0 error count FEC corrected 1 error count After-FEC BER Before-FEC BER FEC uncorrectable frame count Alarm Board environment temperature alarm No input optical power alarm Low input optical power alarm High input optical power alarm LOF alarm SD alarm UAS alarm J0 TIM alarm LOS alarm Only detected for SDH signals k=2 k=2 k=2 k=2 Only detected for 10GE signals Only detected for SDH signals

72

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Type

Item 15-min B1 error out of limit alarm 24-hour B1 error out of limit alarm 15-min B2 error out of limit alarm 24-hour B2 error out of limit alarm 15-min ES out of limit alarm 24-hour ES out of limit alarm 15-min SES out of limit alarm 24-hour SES out of limit alarm 15-min UAS out of limit alarm 24-hour UAS out of limit alarm Receiving signal MS_AIS 15-min received error packet out of limit alarm Alignment loss alarm OTUk J0 TIM alarm 15-min OTUk BIP8 error out of limit alarm 24-hour OTUk BIP8 error out of limit alarm OTUk LOF alarm OTUk loss of multi-frame alarm OTUk layer SM section BDI OTUk layer SM section BEI OTUk layer SM section BIAE OTUk layer SM section IAE 15-min/24-hour OTUk-SM BIP8 CV over-threshold alarm 15-min/24-hour OTUk-SM over-threshold alarm 15-min/24-hour OTUk-SM over-threshold alarm BIP8 BIP8 SES UAS

Remark Only detected for SDH signals

Only detected for SDH signals

Only detected for 10GE signals k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 -

ODUk layer PM section J0 TIM alarm ODUk layer PM section BDI ODUk layer PM section BEI ODUk AIS alarm ODUk LCK alarm ODUk OCI alarm ODUk PT TIM alarm No output optical power alarm Low output optical power alarm High output optical power alarm Laser current out of limit alarm

Confidential and Proprietary Information of ZTE CORPORATION

73

ZXMP M900 (V2.20) Hardware Manual

Type

Item Laser temperature offset out of limit alarm Laser end-of-life alarm Laser fault alarm MZ modulation laser bias power over-threshold alarm Laser shutdown automatically MCU reset

Remark Detection requirement depends on the board configuration -

Event

Laser startup automatically Laser APS shutdown forcibly Laser APS startup forcibly Board configuration is faulty

74

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Convergence Boards
Board ID SRM42 SRM41 GEM2 GEMF GEM8 DSA DSAF DSAE SMU Full Name Four 622 M/155 M SubRate Mux Board Four 2.5 G SubRate Mux Board Two Gigabit Ethernet Mux Board Gigabit Ethernet Mux Board with FEC Eight Gigabit Ethernet Mux Board Data Service Aggregation Board Data Service Aggregation with FEC Data Service Aggregation Electrical interface Board SDH Multiplex Unit OA/OTU/TMUX subrack Applicable Position

SRM41/SRM42 Board
The functions of SRM41 and SRM42 are described in Table 40.
TABLE 40 FUNCTIONS OF SRM41/SRM42 BOARD

Board Function

SRM42 The data multiplexing technology is adopted to implement the Mux/DeMux between four-channel STM-1/STM-4 and STM-16 signal. STM-1/STM-4 optical signals meeting the requirements of G.957 can be accessed.

SRM41 The data multiplexing technology is adopted to implement the Mux/DeMux between four-channel STM-16 and OTU2 signal.

Main Function

Tributary interface function

STM-16 optical signals meeting the requirements of G.957 can be accessed.

Confidential and Proprietary Information of ZTE CORPORATION

75

ZXMP M900 (V2.20) Hardware Manual

Board Function

SRM42 The rate of aggregate signals is STM-16, and the wavelength meets the requirements of ITU-T G.692. Supporting fixed wavelength lasers and tunable wavelength lasers.

SRM41 The wavelength of aggregate signal meets the requirements of ITU-T G.692. And the interfaces comply with optical interface standards S-64.2b in G.691. Supporting SDH synchronous convergence and OTN asynchronous convergence. Supporting FEC/AFEC coding/decoding and complying with ITU-T G.709. The signal rate after coding is 10.709 Gbit/s. The format of FEC/AFEC should be configured in the EMS. Supporting fixed wavelength lasers and tunable wavelength lasers.

Aggregate interface function

The aggregate output supports tunable wavelength lasers. The function is same as that of OTU board. Refer to the section OTU Board for detailed description. Not available

Wavelength tunable function

The aggregate output supports the tuning of 48/96-channel wavelengths in the whole C-band. For 48-channel wavelengths, the channel spacing is 100 GHz. For 96-channel wavelengths, the spacing is 50 GHz. The ERZ modulation can improve the system tolerance to OSNR, and thus the transmission distance can be extended.

ERZ modulation Integrated wavelength supervision

Supporting the integrated wavelength supervision with the channel spacing 50 GHz. For detailed information about the supervision sub-system, please refer to Appendix C. Cooperating with the clock assignment (CA) board, the SRM41/SRM42 boards can perform powerful clock management function. The board can select the best clock automatically according to the synchronization status message (SSM) from the external clock source (2 Mbit/s or 2 MHz), internal clock of board, and the tributary/aggregate clock of other SRM41/SRM42 board in the TMUX subrack. In addition, the clock can be transmitted through aggregate services of the SRM41/SRM42 board.

Clock management

Performance supervision Transparent transmission of overheads Loopback function

Supervising the B1, B2 and J0 performance in tributary and aggregate signals. Transmitting SDH section overheads (SOH) transparently. transmitted overhead bytes can be configured in the EMS. The

Supporting client side loopback and line side loopback to facilitate faults locating.

Operating Principle
The operating principle of SRM41/SRM42 board is illustrated in Figure 47.

76

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 47 OPERATING PRINCIPLE OF SRM41/SRM42 BOARD


G.957 Tributary Optical Module Convergence Unit Clock Processing Unit Aggregate Optical Module G.692 (SRM42) G.692/G.709 (SRM41)

Control and Communication Unit

The SRM41/SRM42 board consists of the tributary optical module, aggregate optical module, convergence unit, clock processing unit and the control and communication unit. Tributary optical module Small form factor pluggable (SFP) modules are adopted in the tributary optical module to input or output client SDH optical signals. SRM42: four-channel STM-1/STM-4 optical signals in compliance with ITU-T G.957 can be accessed. SRM41: four-channel STM-16 optical signals in compliance with ITU-T G.957 can be accessed. Aggregate optical module Line optical signals are input to or output from the aggregate optical module. It supports the tunable wavelength function. SRM42: signals at the rate STM-16 meet the requirements of ITU-T G.692. SRM41: supporting FEC/AFEC coding/decoding. The signal rate after coding is 10.709 Gbit/s. Line optical signals meet the requirements of ITU-T G.692 and G.709, and supports G.709 overhead processing.

Convergence unit As the principle part of SRM41/SRM42 board, the convergence unit performs the multiplexing and demultiplexing function. In the converging direction, tributary signals are converged as the aggregate signal. And then the aggregate signal is sent to the aggregate optical module. In the de-converging direction, the aggregate signal is de-converged to tributary signals which will be output from the tributary optical module.

SRM42 board supports the SDH synchronous convergence format, while SRM41 supports SDH synchronous convergence format and OTN asynchronous convergence format.

Confidential and Proprietary Information of ZTE CORPORATION

77

ZXMP M900 (V2.20) Hardware Manual

In addition, it implements the transparent transmission of SOH and the multiplexing/demultiplexing of data. Clock processing unit This unit can either process clocks alone, or perform more powerful clock processing function cooperating with the CA board, thus guarantying the clock precision of SDH signals. The configuration and management of clock sources comply with ITU-T G.781. The unit can select the best clock as the aggregate transmitting clock according to the SSM from the tributary clock, aggregate clock and the clock provided by the CA board. This clock can be transmitted to the far end together with services, and then be used as the clock source of far-end equipment. The unit can select the best clock from the tributary and aggregate clock, and provide it to the CA board. When all clock sources are in failure, the internal clock of the board will be used as the aggregate transmitting clock (the frequency deviation is less than 4.6 ppm). Control and communication unit This unit monitors the power supply of the board. And it performs the board and EMS supervision function.

Front Panel: Interfaces and Indicators


Taking the SRM41 board as example, Figure 48 illustrates the front panel of the board.

78

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 48 FRONT P ANEL OF SRM41 BOARD

1. Running and alarm indicators 2. Aggregate interface optical interface 3. Tributary interface 4. Tributary interface indicators 5. Laser warning sign 6. Laser class sign

Table 41 describes the front panel and related information for basic operations of the SRM42/SRM41 board.
TABLE 41 FRONT P ANEL DESCRIPTIONS OF SRM42/SRM41 BOARD AND RELATED OPERATION INFORMATION

Board Type Item Board ID Working Frequency Label NOM ALM Indicator Tributary optical interface indicator

SRM42 SRM42

SRM41 SRM41

Indicates board working frequency which is pasted under the board ID Running indicator, green Alarm indicator, red Located at the right side of each tributary optical interface, as illustrated in Figure 48. The indicator is green. It indicates the working status of corresponding tributary interface.

Confidential and Proprietary Information of ZTE CORPORATION

79

ZXMP M900 (V2.20) Hardware Manual

Board Type Item IN OUT Optical Interface DROP1-DR OP4 ADD1-ADD4 Number of Occupied Slots Laser warning sign

SRM42

SRM41

Line input interface, connected with flange, LC/PC connector Line output interface, connected with flange, LC/PC connector Output optical interface of tributary 1-4, LC/PC connector Tributary signals are accessed through SFP modules. Input optical interface of tributary 1-4, LC/PC connector Tributary signals are accessed through SFP modules. 1 1

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OTU10G board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8

Laser class sign

Slots for SRM Board


Operation Precautions

Avoid damaging the fiber pigtail interface while plugging/unplugging the board. Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. The OTUG board should be used as the regenerating board for SRM42 boards. When the FEC technology is adopted, the regenerating OTU10G board with the same FEC technology should be used as the regenerating board for SRM41 boards.

Table 42 lists the SRM42/SRM41 board status and corresponding status of indicators.

TABLE 42 CORRESPONDENCE RELATIONS BETWEEN THE WORKING STATUS AND INDICATOR STATUS OF THE SRM41/SRM42 BOARD

Indicator Status Working Status NOM (Green) ALM (Red) Tributary Optical Interface Indicator (Green)

80

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Indicator Status Working Status NOM (Green) Off ALM (Red) Off Tributary Optical Interface Indicator (Green) -

The Bootrom program is downloaded. The board is waiting for configuration. The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. The board is performing self-test upon power on. The board is in the downloading status The tributary optical interface is working normally. The tributary optical interface is working abnormally.

The green indicator and the red indicators flash alternately. Flashing slowly and regularly Flash slowly regularly and Off

Normally on

The red indicator and the green indicator flashes quickly for three times. The red indicator and the green indicator flashes slowly at the same times. -

On

Off

Performance and Alarm Messages


THE PERFORMANCE, AL ARM AND EVENT INFORMATION OF THE LISTED IN TABLE 43, SRM42/SRM41 BOARD ARE

Confidential and Proprietary Information of ZTE CORPORATION

81

ZXMP M900 (V2.20) Hardware Manual

Table 44 and Table 45 respectively.


TABLE 43 PERFORM ANCE MESSAGES OF SRM42/SRM41 BOARD

Detection Point Board

Performance Items Environment temperature Output optical power Laser bias current

Remark Only for SRM41 board Only for SRM42 board Detection requirement depends on the board configuration -

Aggregate transmitter

Inner-module temperature Laser temperature offset MZ modulation bias power Laser TEC current Input optical power 15-min B1 error count 15-min ES 15-min SES 15-min UAS 15-min B2 error count 15-min BER FEC corrected BE count Before-FEC BER FEC uncorrectable frame

Only for SRM42 board

Aggregate receiver

FEC corrected 0 error count FEC corrected 1 error count After-FEC BER 15-min OTU2 SM BIP8 error count 15-min ODU2 PM BIP8 error count 15-min TCMi BIP8 error count 15-min TCMi BEI error count 15-min TCMi UAS error count 15-min TCMi SES error count 15-min TCMi BIP8 BE over-threshold 24-hour TCMi BIP8 BE over-threshold

These performances are detected only when the SRM41 board is configured with bit decoding or decoding/coding function.

i=1-6. these performances are detected only when SRM41 is configured as FEC decoding/coding, and TCM is configured in the mode of running or monitoring.

Tributary receiver

15-min B1 error count 15-min B2 error count 15-min ES 15-min SES 15-min UAS 15-min BER

82

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Performance Items Input optical power Inner-module temperature

Remark It depends on the board configuration whether to detect this item.

Tributary transmitter

Laser bias current Output optical power

Only for SRM41 board

Confidential and Proprietary Information of ZTE CORPORATION

83

ZXMP M900 (V2.20) Hardware Manual

TABLE 44 ALARM MESSAGES OF SRM42/SRM41 BOARD

Detection Point Board

Alarms Board environment temperature alarm No output optical power Low output optical power High output optical power Laser current over-threshold alarm Laser temperature alarm offset over-threshold

Remark Only for SRM41 board It depends on the board configuration whether to detect this item. Only for SRM42 board It depends on the board configuration whether to detect this item. Only for SRM42 board -

Aggregate transmitter

TEC current over-threshold alarm

Inner-module temperature over-threshold alarm MZ modulation bias power over-threshold alarm Laser end-of-life alarm No input optical power alarm Aggregate receiver Low input optical power alarm High input optical power alarm LOF alarm UAS alarm SD alarm LOS alarm J0 TIM alarm 15-min/24-hour B1 over-threshold alarm 15-min/24-hour B2 over-threshold alarm error error count count

Only for SRM42 board

15-min/24-hour ES over-threshold alarm 15-min/24-hour SES over-threshold alarm 15-min/24-hour UAS over-threshold alarm 15-min/24-hour over-threshold alarm before-FEC BE Only for SRM41 board

15-min/24-hour after-FEC BE over-threshold alarm OTU2 LOF alarm OTU2 loss of multi-frame alarm OTU2 J0 TIM alarm

84

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Alarms 15-min/24-hour OTU2 over-threshold alarm OTU2 layer SM section BDI OTU2 layer SM section BEI OTU2 layer SM section BIAE OTU2 layer SM section IAE ODU2 layer PM section BDI ODU2 layer PM section BEI ODU2 layer PM section IAE ODU2 AIS alarm ODU2 OCI alarm ODU2 PT TIM alarm TCMi J0 TIM alarm TCMi layer BDI TCMi layer BIAE TCMi layer IAE TCMi AIS alarm TCMi LCK alarm TCMi LTC alarm TCMi OCI alarm LOF alarm LOS alarm UAS alarm SD alarm J0 TIM alarm 15-min/24-hour B1 over-threshold alarm error error count count BIP8 error

Remark

i=1-6, Only for SRM41 board

Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic Only for SDH traffic It depends on the board configuration whether to detect this item.

Tributary receiver

15-min/24-hour B2 over-threshold alarm

15-min/24-hour ES over-threshold alarm 15-min/24-hour SES over-threshold alarm 15-min/24-hour UAS over-threshold alarm Receiving signal MS_AIS No input optical power alarm Low input optical power alarm High input optical power alarm

Confidential and Proprietary Information of ZTE CORPORATION

85

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Alarms No output optical power alarm Low output optical power alarm

Remark It depends on the board configuration whether to detect this item. Only for SRM41 board

Tributary transmitter

High output optical power alarm Laser current over-threshold alarm Inner-module temperature over-threshold alarm

TABLE 45 EVENT MESSAGES OF SRM42/SRM41 BOARD

Detection Point Tributary transmitter

Item Tributary light shut-down (laser shut-down) Tributary light start up (laser startup) Tributary light shut-down (laser shut-down) Tributary light startup (laser startup) Clock switching succeeds/fails

Aggregate transmitter Board

GEM2 Board
Functions
GEM2 (Two Gigabit Ethernet Mux Board) board receives optical GE signals complying with IEEE802.3 from SDH equipment, carries out O/E/O conversion for them and finally combines them into an optical signal with special wavelength complying with ITU-T G.692. It also implements the opposite procedure of combination, that is, converts ITU-T G.692 optical signal into two GE optical signals.

Tributary side Two optical GE signals, complying with IEEE802.3, are accessed at the tributary side of the GEM2 board.

Aggregate side Optical signal on the aggregate side of GEM2 board meets the specification of ITU-T G.692 with the rate up to 2.5 Gbit/s. Check B1, B2 and J0 bytes for SDH signals. Support both fixed lasers and tunable lasers at the aggregate side. In case of tunable lasers, 4 or 8 continuous wavelengths in C band can be tuned. The channel spacing is 100 GHz for 4 channels, while it is 50 GHz for 8 channels.

86

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Operating Principle
Figure 49 illustrates the operating principle of GEM2 board.
FIGURE 49 OPERATING PRINCIPLE OF GEM2 BOARD

GE Convergence Unit GE Optical Module GE Optical Module SDH Overhead Processing Unit MAC Controller Unit

Convergence Unit

GE optical signals

STM-16 Aggregate optical module

G.692

Control and Communication Unit

In the multiplexing direction (GE STM-16), the GE optical signals are accessed by two GE optical modules respectively. They are processed in the GE convergence unit and multiplexed into an electrical STM-16 signal. Then the electrical STM-16 signal is input to the aggregate optical module and converted into an optical signal complying with ITU-T G.692. In the demultiplexing direction (STM-16 GE), an aggregate optical signal (complying with ITU-T G.692) is accessed through the aggregate optical module. The aggregate signal is processed in the GE convergence unit and separated into two electrical GE signals. Then these two electrical signals are converted into two optical signals and output by two GE optical modules respectively. GEM2 board consists of two GE optical modules, a GE convergence unit, an aggregate optical module, and the control and communication unit.

GE Optical Module GEM2 board has two GE optical modules. Each module accesses an optical GE signal (IEEE802.3) and converts it into an electrical signal in the multiplexing direction, while receives an electrical GE signal from the GE convergence unit and converts it into an optical signal (IEEE802.3) in the demultiplexing direction.

GE Convergence Unit The GE convergence unit implements the multiplexing/demultiplexing between two electrical GE signals and an electrical STM-16 signal. It consists of an MAC controller unit, a convergence unit and an SDH overhead processing unit.

Confidential and Proprietary Information of ZTE CORPORATION

87

ZXMP M900 (V2.20) Hardware Manual

In the multiplexing direction The MAC controller unit receives two electrical GE signals and identifies MAC addresses in the Ethernet frames. The convergence unit combines two GE signals into one signal and sends it to the SDH overhead processing unit. The SDH overhead processing unit mapps the Ethernet frames into an SDH frame and processes SDH overheads and generates B1/B2/J0 bytes etc. Finally, it outputs an electrical STM-16 signal to the aggregate optical module. In the demultiplexing direction The SDH overhead processing unit receives an electrical STM-16 signal from the aggregate optical module. It processes the signals overheads, checks the B1/B2/J0 bytes and demaps the SDH frame to GE frame. The convergence unit demultiplexes the electrical GE signal received from the SDH overhead processing unit into two GE signals and sends them to the MAC controller unit. The MAC controller unit determines the Ehternet transmit ports for the two electrical GE signals and outputs them to corresponding GE optical modules. Aggregate Optical Module GEM2 board has only one aggregate optical module. In the multiplexing direction, the aggregate optical module receives an electrical STM-16 signal from the GE convergence unit, converts it into an optical signal (ITU-T G.692) and then output the optical signal. In the demultiplexing direction, it converts the optical signal (ITU-T G.692) received from user equipment into an electrical STM-16 signal and then sends it to the GE convergence unit. Control and Communication Unit It monitors the power supply of the board and the running of the board and performs the supervision function of the EMS.

Front Panel: Interfaces and Indicators


The front panel of the GEM2 board is shown in Figure 50.

88

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 50

FRONT PANEL OF GEM2 BOARD

1. Running and alarm indicators 2. Aggregate optical interface 3. Tributary optical Ethernet interface 4. Indicator of tributary optical Ethernet interface 5. Laser warning sign 6. Laser class sign

Table 46 describes the front panel and related information for basic operations of GEM2 board.
TABLE 46 DESCRIPTION OF GEM2 BOARDS FRONT PANEL AND RELATED OPERATION INFORMATION

Board Item Board ID Indicator NOM ALM

GEM2 GEM2 Running indicator, green Alarm indicator, red

Confidential and Proprietary Information of ZTE CORPORATION

89

ZXMP M900 (V2.20) Hardware Manual

Board Item Indicator of optical Ethernet interface IN OUT DROP1 ADD1 DROP2 ADD2

GEM2 Located at the right side of each optical Ethernet interface, as shown in Figure 50. It is a green indicator used to indicate the running status of corresponding optical Ethernet interface. Line input interface, connected through a fiber optic adaptor, LC/PC connector Line output interface, connected through a fiber optic adaptor, LC/PC connector Optical output Ethernet interface of tributary 1, LC/PC connector Optical input Ethernet interface of tributary 1, LC/PC connector Optical output Ethernet interface of tributary 2, LC/PC connector Optical input Ethernet interface of tributary 2, LC/PC connector Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of GEM2 board is CLASS 1 1 All slots in OTU subrack

Optical interface

Laser warning sign

Laser class sign Number of occupied slot

Slots for GEM2 board

Slots in OA subrack except slot 6-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging optical plugging/unplugging the board. connectors while

Operation precautions

Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time. OTUG board should be used as the regeneration board for GEM2 board.

Table 47 lists the relations between the working status and corresponding indicator status of GEM2 board.

90

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 47 RELATIONS BETWEEN THE WORKING STATUS AND INDICATOR STATUS OF GEM2 BOARD

Indicator Status Working Status Ethernet Optical Interface Indicator (Green) -

NOM (Green)

ALM (Red)

Waiting for configuration Running normally Alarming Initializing

The green indicator and the red indicator flash alternately and slowly. Flashing slowly and regularly Flashing slowly and regularly ON OFF ON Flashing slowly and regularly

Waiting for download

The green indicator and the red indicator flash quickly at the same time The green indicator and the red indicator flash slowly at the same time Flashing slowly and regularly -

Downloading status Tributary interface works normally Tributary interface works abnormally

ON

OFF

Note: The - symbol means that the indicator status is indefinite.

Performance and Alarm Messages


The performance messages of the GEM2 board are listed in Table 48.
TABLE 48 PERFORMANCE MESSAGES OF GEM2 BOARD

Detection Point

Item Output optical power Laser bias current

Remark -

Aggregate transmitter

Laser temperature Inner-module temperature TEC current

Aggregate receiver

Input optical power 15-min B1 error count 15-min B2 error count 15-min ES

Confidential and Proprietary Information of ZTE CORPORATION

91

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Item 15-min SES 15-min UAS 15-min BER Total received packet count Total received byte count 15-min received error packet ratio

Remark It depends on the board configuration whether to detect this item. It depends on the board configuration whether to detect these items.

Tributary GE receiver

15-min received error packet count

Input optical power

Total sent packet count Total sent packet count Tributary GE transmitter Output optical power Laser bias current Inner-module temperature

The alarm messages of the GEM2 board are listed in Table 49.
TABLE 49 ALARM MESSAGES OF GEM2 BOARD

Detection Point

Item High output power alarm Low output power alarm No output power alarm High laser bias current alarm

Remark -

Aggregate transmitter

High TEC current alarm Laser temperature offset out of limit alarm Inner-modulation temperature out of limit alarm Laser end of lifetime alarm

Aggregate receiver

High input power alarm Low input power alarm No input power alarm LOF alarm

92

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item UAS alarm SD alarm LOS alarm J0 Track Identifier Mismatch (TIM) alarm 15-min B1 BE out of limit alarm 15-min B2 BE out of limit alarm 15-min ES out of limit alarm 15-min SES out of limit alarm 15-min UAS out of limit alarm 24-hour B1 BE out of limit alarm 24-hour ES out of limit alarm 24-hour SES out of limit alarm 24-hour UAS out of limit alarm Receiving signal MS_AIS alarm LOS alarm 15-min received error packet count out of limit alarm 24-hour received error packet count out of limit alarm Link fail alarm High input power alarm Low input power alarm No input power alarm High output power alarm Low output power alarm

Remark It depends on the board configuration whether to detect these items.

Tributary GE receiver

Tributary GE transmitter

No output power alarm High laser bias current alarm Inner-module temperature out of limit alarm

It depends on the board configuration whether to detect these items.

Confidential and Proprietary Information of ZTE CORPORATION

93

ZXMP M900 (V2.20) Hardware Manual

GEMF Board
Functions
GEMF (Gigabit Ethernet Mux Board with FEC) implements the multiplexing/demultiplexing between two-channel GE signals and STM-16 signals through the O/E/O conversion. Tributary side Two optical GE signals, complying with IEEE802.3 are accessed at the tributary side of GEMF board. Aggregate side The optical signal at the aggregate side complies with ITU-T G.692 and G.709. The highest rate of the signal is 2.667 Gbit/s. Checks the byte B1, B2 and J0 in the STM-16 signal. Supports both fixed wavelength lasers and tunable wavelength lasers. In case of tunable lasers, 4 or 8 continuous wavelengths in C band can be tuned. The channel spacing is 100 GHz for 4 channels, while it is 50 GHz for 8 channels.

Operating Principle
The operating principle of the GEMF board is illustrated in Figure 51.
FIGURE 51 OPERATING PRINCIPLE OF GEMF BOARD
GbE Convergence Unit GE Optical Module GE Optical Module G.692/ G.709

GbE optical signals

MAC Controller Unit

Convergence Unit

SDH OTN Overhead STM-16 Processing Processing Unit Unit

OTN Optical Module

Control and Communication Unit

Multiplexing direction (GE STM-16) Two-channel GE signals in compliance with IEEE802.3 are accessed through the GE optical modules. They are processed in the GE

94

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

convergence unit and then in the OTN processing unit. Finally they are output an aggregate signal (STM-16) in compliance with ITU-T G.692 and G.709. Demultiplexing direction (STM-16 GE) The aggregate signal (STM-16) complying with ITU-T G.692 and G.709 is accessed through the OTN optical module. It is processed in the OTN processing unit and then in the GE convergence unit. Finally it is demultiplexed into two-channel GE signals which are output after being transferred to corresponding optical signals in two GE optical modules respectively. The GEMF board consists of two GE optical modules, the GE convergence unit, OTN processing unit, an OTN optical module, and the control and communication unit. GE optical module In the multiplexing direction, the GE optical signal in compliance with IEEE802.3 (2002) is accessed to the module and converted to corresponding electrical signal through O/E conversion. In the demultiplexing direction, the GE signal in compliance with IEEE802.3 (2002) is output after E/O conversion.

GE convergence unit The GE convergence unit is composed of the MAC controller unit, the convergence unit and the SDH overhead processing unit. In this unit, two GE signals are multiplexed, while an STM-16 signal is demultiplexed. In the multiplexing direction, the MAC controller unit identifies the MAC address in the Ethernet frames of two GE electrical signals output from the GE optical modules. In the convergence unit, two GE signals are multiplexed into one signal which will be forwarded to the SDH overhead processing unit. After the mapping from Ethernet frames to STM-16 frame, overhead processing and the generation of the bytes B1/B2/J0, the signal is transferred to the OTN processing unit as an STM-16 electrical signal. In the demultiplexing direction, the STM-16 electrical signal output from the OTN processing unit is transmitted to the SDH overhead processing unit, which will process overheads and check the bytes B1/B2/J0 in the STM-16 signal. Then the signal is demultiplexed into two GE signals. These two signals are transferred to the MAC controller unit through the convergence unit. The MAC controller unit selects the transmitting ports for the electrical signals and forwards them to corresponding GE optical modules.

OTN processing unit It implements the FEC coding/decoding for STM-16 signals, the insertion and check of ODU1 Trail Track Identifier (TTI) in the SM byte, and the checkout of ODU1 BIP-8. In the multiplexing direction: It receives the STM-16 signal from the GE convergence unit. After completing the FEC coding of the signal

Confidential and Proprietary Information of ZTE CORPORATION

95

ZXMP M900 (V2.20) Hardware Manual

and inserting the TTI and multi-frame byte, it outputs the STM-16 signal (complying with G.709) to the OTN optical module. In the demultiplexing direction: The OTN processing unit receives the aggregate signal from the OTN optical module. Through completing the FEC decoding, counting the corrected bit error, extracting the TTI and counting the BIP-8, it converts the aggregate signal to the STM-16 electrical signal and then forwards it to the GE convergence unit.

OTN optical module GEMF board provides an OTN optical module: In the multiplexing direction: It receives the G.709 STM-16 electrical signal, converts it to the STM-16 optical signal complying with both G.692 and G.709 through E/O conversion. In the demultiplexing direction: It converts the STM-16 optical signal complying with G.692 and G.709 to the electrical signal and forwards it to the OTN processing unit.

Control and communication unit This unit monitors the power supply of the board. And it performs the supervision function for board and EMS.

Front Panel: Interfaces and Indicators


The front panel of the GEMF board is shown in Figure 52.

96

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 52 FRONT P ANEL OF GEMF BOARD

1. Running and alarm indicators 2. Aggregate interface optical interface 3. Tributary interface 4. Tributary interface indicators 5. Laser warning sign 6. Laser class sign

Table 50 describes the front panel and related information for basic operations of the GEMF board.
TABLE 50 FRONT P ANEL DESCRIPTIONS OF GEMF BOARD AND RELATED OPERATION INFORM ATION

Board Item Board ID Operating label frequency NOM ALM Indicator Optical Ethernet interface indicator IN

GEMF GEMF Indicates board operating frequency which is pasted under board ID Running indicator, green Alarm indicator, red Two green indicators for two tributary optical Ethernet interface respectively, as shown in Figure 52. Aggregate input interface, connected with a flange, LC/PC connector

Optical interface

Confidential and Proprietary Information of ZTE CORPORATION

97

ZXMP M900 (V2.20) Hardware Manual

Board Item OUT DROP1 ADD1 DROP2 ADD2 Number of occupied slot Laser warning sign

GEMF Aggregate output interface, connected with a flange, LC/PC connector Optical output Ethernet interface of tributary 1, LC/PC connector Optical input Ethernet interface of tributary 1, LC/PC connector Optical output Ethernet interface of tributary 2, LC/PC connector Optical input Ethernet interface of tributary 2, LC/PC connector 1 Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OTU10G board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber pigtail plugging/unplugging the board. interface while

Laser class sign

Slots for GEMF board

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for unused optical connectors in time. The OTUFG board should be used as the regenerating board for the GEMF board. The rate of abutting interfaces should be same. Otherwise, the traffic will be obstructed.

Table 51 lists the relationship between the board status and corresponding status of indicators.
TABLE 51 CORRESPONDENCE RELATIONS BETWEEN THE WORKING STATUS AND INDICATOR STATUS OF GEMF BOARD

Indicators Working Status Ethernet Optical Interface Indicator (Green) -

NOM (Green)

ALM (Red)

The Bootrom program is downloaded. The FPGA program is downloaded. The board is waiting for configuration.

Off

Off

The red indicator and the green indicator flash slowly for 30 seconds. The red indicator and the green indicator flash alternately.

98

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Indicators Working Status Ethernet Optical Interface Indicator (Green) -

NOM (Green)

ALM (Red)

The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. Board initialing The board is waiting for download Downloading status The tributary interface has no LOS alarm. Bootrom program The interface alarm. tributary has LOS

Flashing regularly Flashing regularly On

slowly

and

Off

slowly

and

On Flashing slowly and regularly

The red indicator and the green indicator flash quickly at the same time. The red indicator and the green indicator flash slowly at the same time. Off Off -

On Off

Performance and Alarm Messages


The performance messages of the GEMF board to be detected and monitored are listed in Table 52.
TABLE 52 PERFORM ANCE MESSAGES OF GEMF BOARD

Detection Point

Performance Items Output optical power

Remark -

Aggregate transmitter

Laser bias current Laser temperature TEC current

Aggregate receiver

Input optical power 15-min B1 error 15-min B2 error 15-min ES 15-min SES 15-min UAS 15-min BER

Confidential and Proprietary Information of ZTE CORPORATION

99

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Performance Items Bit error corrected by FEC BER before FEC Frame unable to be corrected by FEC 0 bit error corrected by FEC 1 bit error corrected by FEC BER after FEC 15-min OTUk BIP8 error Total received packets Total received bytes

Remark It depends on the board configuration whether to detect this item. It depends on the board configuration whether to detect this parameter. It depends on the board configuration whether to detect this parameter. It depends on the board configuration whether to detect this parameter.

Tributary receiver

GE

15-min received packet error ratio 15-min received packet error Input optical power Total sent packets Total sent bytes Output optical power

Tributary transmitter

GE Laser bias current

Inner-module temperature

Table 53 lists the main alarms of GEMF board.


TABLE 53 ALARM MESSAGES OF GEMF BOARD

Detection Point

Alarms High output power alarm Low output power alarm No output power alarm

Remark -

Aggregate transmitter

High laser bias current alarm Module temperature out of limit alarm of inner module Laser end of lifetime alarm High cooler current alarm

Aggregate receiver

High input power Low input power

100

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Alarms No input power LOF alarm Unavailable Signal (UAS) alarm SD alarm LOS alarm J0 Track Identifier Mismatch (TIM) alarm 15-min B1 BE out of limit alarm 15-min B2 BE out of limit alarm 15-min ES out of limit alarm 15-min SES out of limit alarm 15-min UAS out of limit alarm Receiving signal MS_AIS alarm OTUk J0 TIM alarm 15-min BIP8 error out of limit alarm OTUk LOF alarm OTUk Loss of Multi-frame (LOM) alarm 15-min before-FEC BE out of limit threshold alarm 15-min uncorrectable over-threshold alarm frame

Remark packet ratio It depends on the board configuration whether to detect these items. It depends on the board configuration whether to detect these items.

24-hour before-FEC BE out of limit alarm 24-hour uncorrectable over-threshold alarm 24-hour B1 error out of limit alarm 24-hour ES out of limit alarm 24-hour SES out of limit alarm 24-hour UAS out of limit alarm LOS alarm Received error over-threshold alarm Tributary GE receiver Link fail alarm High input power alarm Low input power alarm No input power alarm Tributary transmitter GE High output power alarm Low output power alarm No output power alarm High laser bias current alarm frame

Confidential and Proprietary Information of ZTE CORPORATION

101

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Alarms Module temperature out of limit alarm of inner module

Remark

GEM8 Board
Functions
GEM8 (Eight Gigabit Ethernet Mux Board) board implements the multiplexing/demultiplexing between eight optical GE signals and an OTU2 signal through O/E/O conversion. Tributary side Eight optical GE signals, complying with IEEE802.3, are accessed at the tributary side of the GEM8 board. Supports related performance detection of GFP. Aggregate side Outputs optical signal, complying with ITU-T G.694.1, with the OTU2 signal structure specified in ITU-T G.709. Support the OTU2 interface and related performance detection specifed in ITU-T G.709. FEC can be configured as standard FEC or AFEC. Support the encapsulation of GFP-T data packets, complying with ITU-T G.704.1. Support both fixed lasers and tunable lasers. The tuning function of tunable lasers covers the wavelengths in the whole C band.

Operating Principle
Figure 53 illustrates the operating principle of GEM8 board.

102

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 53

OPERATING PRINCIPLE OF GEM8 BOARD


GE Optical Module

8 GE optical signals

Convergence Unit

GE Optical Module

OTN Processing Unit

10G optical module

G.694.1/ G.709

In the multiplexing direction (GE OTU2), eight optical GE signals are accessed through eight GE optical modules respectively. Then they are processed by the convergence unit and the OTN processing unit. Finally, they are converted into an aggregate signal (OTU2 signal) meeting the specifications in ITU-T G.694.1 and G.709. In the demultiplexing direction (OTU2 GE), an aggregate signal complying with ITU-T G.694.1 and G.709 is accessed to the 10 G optical module. After being processed by the OTN processing unit and the convergence unit, the signal is demultiplexed into eight electrical GE signals. Finally, eight GE optical modules convert these electrical signals into optical signals and output them. GEM8 board consists of eight GE optical modules, a convergence unit, an OTN processing unit, a 10 G optical module and the control and communication unit. GE Optical Module GEM8 board has eight GE optical modules. Each of them uses SFP optical module to input or output optical GE signal in compliance with IEEE802.3. Convergence Unit It checks the perfomance of client service signals, performs the GFP-T mapping/demapping, and implements the convergence and divergence of GFP-T frames. OTN Processing Unit The OTN processing unit realizes the framing/deframing of OTU2 signal, which complies with ITU-T G.709. In addition, it supports the detection of FEC-related performances. 10 G Optical Module

...

...

Control and Communication Unit

Confidential and Proprietary Information of ZTE CORPORATION

103

ZXMP M900 (V2.20) Hardware Manual

This module receives electrical 10G OTN signal from the OTN processing unit, converts it into OTU2 optical signal and outputs it. On the opposite direction, it receives OTU2 optical signal from the line, converts it into an electrical 10G OTN signal and then sends it to the OTN processing unitl. Control and Communication Unit This unit monitors the power supply of the board and the running status of the board, and performs the supervision function of the EMS.

Front Panel: Interfaces and Indicators


The front panel of GEM8 board is shown in Figure 54.
FIGURE 54 FRONT PANEL OF GEM8 BOARD

1. Running and alarm indicators 2. Aggregate optical interface 3. Tributary optical Ethernet interface 4. Indicator of tributary optical Ethernet interface 5. Laser warning sign 6. Laser class sign

104

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Table 54 describes the front panel and related information for basic operations of GEM8 board.
TABLE 54 DESCRIPTION OF GEM8S FRONT PANEL AND RELATED OPERATION INFORMATION

Board Item Board ID NOM ALM Indicator Optical Ethernet interface indicator IN OUT ADDn DROPn

GEM8 GEM8 Running indicator, green Alarm indicator, red Eight green indicators are available on the lower part of the front panel, as shown in Figure 54. Each of them corresponds to a tributary optical Ethernet interface. Line input optical interface, LC/PC connector Line output optical interface, LC/PC connector Tributary input optical Ethernet interface n, n=1-8, LC/PC connector Tributary output optical Ethernet interface n, n=1-8, LC/PC connector Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of GEM8 board is CLASS 1 2

Optical interface

Laser warning sign

Laser class sign Number of occupied slot

All slots in OTU subrack


Slots for GEM8 board

Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8
Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Operation precautions

Table 55 lists the relations between the working status and corresponding indicator status of GEM8 board.

Confidential and Proprietary Information of ZTE CORPORATION

105

ZXMP M900 (V2.20) Hardware Manual

TABLE 55 RELATIONS BETWEEN THE WORKING STATUS AND INDICATOR STATUS OF GEM8 BOARD

Indicator Status Working Status Ethernet Optical Interface Indicator (Green) ON OFF

NOM (Green)

ALM (Red)

Downloading BootROM program Downloading FPGA program Waiting for configuration Running normally Alarming Initializing Waiting for download Downloading status Tributary interface has no LOS alarm Tributary interface has LOS alarm

OFF Flashing quickly

OFF ON

The green indicator and the red indicator flash alternately and slowly. Flashing slowly and regularly Flashing slowly and regularly OFF ON

The green indicator and red indicator flash quickly three times. The green indicator and red indicator flash quickly at the same time. The green indicator and red indicator flash slowly at the same time. -

Note: The - symbol means that the indicator status is indefinite.

Performance and Alarm Messages


The performance messages of GEM8 board are listed in Table 56.
TABLE 56 PERFORMANCE MESSAGES OF GEM8 BOARD

Detection Point

Item Output optical power

Remark Only detected when M-Z modulated laser is used. -

Aggregate transmitter

Laser bias current Module temperature offset MZ modulator bias voltage

Aggregate receiver

Input optical power FEC uncorrectable frame FEC corrected bit error

106

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item FEC corrected 0 bit error FEC corrected 1 bit error After-FEC BER Before-FEC BER 15-min OTU2 SM_BIP8 error 15-min ODU2 PM_BIP8 error 15-min OTU2 SM ES 15-min OTU2 SM SES 15-min OTU2 SM UAS 15-min ODU2 PM ES 15-min ODU2 PM SES 15-min ODU2 PM UAS 15-min OTU2 SM BEI error 15-min ODU2 PM BEI error 15-min TCMi BIP8 error 15-min TCMi BEI 15-min TCMi UAS 15-min TCMi ES 15-min TCMi SES Total received package Total received bytes

Remark i=1-6. Configured as FEC decoding. And TCM is configured as running mode or monitoring mode. It depends on the board configuration whether to detect this item. It depends on the board configuration whether to detect these items. -

Tributary GE receiver

Input optical power Sent GFP client data frame Sent GFP client management frame Total sent packets Total sent bytes Output optical power

Tributary GE transmitter

Laser bias current Inner-module temperature Transmitted GFP client data frame Transmitted GFP client management frame

Confidential and Proprietary Information of ZTE CORPORATION

107

ZXMP M900 (V2.20) Hardware Manual

The alarm messages of GEM8 board are listed in Table 57.


TABLE 57 ALARM MESSAGES OF GEM8 BOARD

Detection Point

Item High output power alarm Low output power alarm No output power alarm High laser bias current alarm

Remark Only detected when M-Z modulated laser is used. -

Aggregate transmitter

Laser temperature offset out of limit alarm MZ modulator bias voltage out of limit alarm Laser end of lifetime alarm Laser failure alarm

Aggregate receiver

High input power alarm Low input power alarm No input power alarm TCMi layer TIM TCMi layer BDI TCMi layer BIAE TCMi layer IAE TCMi AIS alarm TCMi LCK alarm TCMi LTC alarm TCMi OCI alarm 15-min OTU2 BIP8 error out of limit alarm 15-min before-FEC bit error out of limit alarm 15-min after-FEC bit error out of limit alarm 15-min ODU2 PM_BIP8 error out of limit alarm 15-min SM ES out of limit alarm 15-min SES out of limit alarm 15-min UAS out of limit alarm 24-hour SM ES out of limit alarm 24-hour SES out of limit alarm 24-hour UAS out of limit alarm

i=1-6

108

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item 24-hour OTU2 SM_BIP8 error out of limit alarm 24-hour ODU2 PM_BIP8 error out of limit alarm 24-hour before-FEC bit error out of limit alarm 24-hour after-FEC bit error out of limit alarm 15-min TCMi BIP8 error out of limit alarm 24-hour TCMi BIP8 error out of limit alarm LOS alarm OTU2 AIS alarm OTU2 LOF alarm OTU2 loss of multiframe alarm OTU2 TIM alarm ODU2 PM field TIM alarm OTU2 SM field BDI (Backward Defect Indication) OTU2 SM field BEI (Backward Error Indication) OTU2 SM field BIAE (Backward Incoming Alignment Error) OTU2 SM field IAE (Incoming Alignment Error) ODU2 PM field BDI (Backward Defect Indication) ODU2 AIS alarm ODU2 LCK alarm ODU2 OCI alarm OPU signal PT mismatch

Remark i=1-6 i=1-6 -

Tributary GE receiver

LOS alarm Loss of synchronization alarm Received CRC error packet out of limit alarm 15-min 8B/10B CV out of limit alarm 15-min 8B/10B CV ES out of limit alarm 15-min 8B/10B CV SES out of limit alarm

Confidential and Proprietary Information of ZTE CORPORATION

109

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Item 15-min 8B/10B CV UAS out of limit alarm 24-hour 8B/10B CV out of limit alarm 24-hour 8B/10B CV ES out of limit alarm 24-hour 8B/10B CV SES out of limit alarm 24-hour 8B/10B CV UAS out of limit alarm 24-hour received package out of limit alarm High input power alarm Low input power alarm No input power alarm High output power alarm Low output power alarm No output power alarm High laser current alarm Module temperature out of limit alarm of inner module Laser failure alarm Laser end of life alarm GFP client signal failure alarm GFP loss of synchronization alarm

Remark -

It depends on the board configuration whether to detect these items.

Tributary GE transmitter

15-min 8B/10B CV out of limit alarm 15-min 8B/10B CV ES out of limit alarm 15-min 8B/10B CV SES out of limit alarm 15-min 8B/10B CV UAS out of limit alarm 24-hour 8B/10B CV out of limit alarm 24-hour 8B/10B CV ES out of limit alarm 24-hour 8B/10B CV SES out of limit alarm 24-hour 8B/10B CV UAS out of limit alarm

110

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

The event messages of GEM8 board are listed in Table 58.


TABLE 58 EVENT MESSAGES OF GEM8 BOARD

Detection Point

Item Laser shutdown automatically

Remark It depends on the board configuration whether to detect this item. -

Tributary transmitter

Laser startup automatically SFP module unplugged SFP module plugged Laser shutdown automatically

Aggregate transmitter

Laser startup automatically Laser APS shutdown forcibly Laser APS startup forcibly Clock switching successfully

Board

Clock switching failed MCU reset EEPROM data error

DSA Board
Functions
DSA (Data Service Aggregation) board implements the multiplexing/ demultiplexing between eight data service signals, such as GE, FC, ESCON, FICON and DVB signals, and STM-16 signals through O/E/O conversion. Tributary side DSA board supports the access of eight data service signals at its tributary side. Each tributary interface allows the access of any kind of data service signal, GE, FC, ESCON, FICON or DVB. Aggregate side Two bidirectional optical interfaces with the rate of 2.5 Gbit/s are available at the aggregate side of DSA board. They comply with the specification of ITU-T G.692. DSA board also provides the function of checking of checking B1, B2 and J0 bytes for SDH signals.

Confidential and Proprietary Information of ZTE CORPORATION

111

ZXMP M900 (V2.20) Hardware Manual

Operating Principle
Figure 55 illustrates the operating principle of DSA board.
FIGURE 55 OPERATING PRINCIPLE OF DSA BOARD

Multiservice Convergence Unit Tributary Optical Module ... ... SDH Overhead Processing Unit G.692 STM-16 Aggregate Optical Module

Mapping Unit

Convergence Unit

Data service signals

Tributary Optical Module

Dual optical interfaces (2.5 Gbits/s)

Control and Communication Unit

In the multiplexing direction (data service signals STM-16), eight data service signals who can be of the same kind of data service or different kinds (GE, FC, ESCON, FICON or DVB), are accessed via eigth tributary optical modules. Then the DSA board mapps these data service signals into SDH frames, performs the flow control function, detects the performance of signals and finally outputs the aggregate signals throught the aggregate optical module. In the demultiplexing direction (STM-16 data service signals), the DSA board receives two aggregate optical signals. It detects the performance of the signals, demultiplexes them into client data (i.e. data service signals), and then output these data service signals to user equipment through corresponding tributary optical modules after E/O conversion. DSA board consists of eight tributary optical modules, a multiservice convergence unit, an aggregate optical module, and the control and communication unit, as introduced below. Tributary Optical Module DSA board has eight tributary optical modules. SFP module is used in each tributary optical module. In the multiplexing direcetion Each tributary optical module receives an optical data service signal (GE, FC, ESCON, FICON or DVB), converts it into an electrical signal and forwards the electrical signal to the multiservice convergence unit. In the demultiplexing direction

112

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Each tributary optical module converts the electrical data signal received from the multiservice convergence unit into an optical signal and outputs it. Multiservice Convergence Unit It implements the multiplexing/demultiplexing between eight electrical data signals and two STM-16 signals. The multiservice convergence unit consists of a convergence unit, a mapping unit and an SDH overhead processing unit. In the multiplexing direction The convergence unit combines the eight electrical data signals received from eight tributary optical modules. Then the combined signals are framed into GFP (Generic Framing Procedure) and then mapped into VC by the mapping unit. The SDH overhead processing unit maps the data frames received from the mapping unit into STM-16 frames, processes related overheads and checks B1, B2 and J0 bytes. After that, it sends the electrical STM-16 signals to the aggregate optical molude.

Note: GFP (Generic Framing Procedure) frames are classified into two types: GFP-T (Transparent GFP) and GFP-F (Framed GFP). GFP-T: GFP-T frames have fixed length. It is unnecessary to start processing a frame until the full frame is received. Therefore, GFP-T frames can be processed timely. GFP-F: GFP-F frames have variable length. Only when the full frame is received, will the frame be processed.

GE data service signals can be mapped into either GFP-T frames or GFP-T frames. However, the other data service signals, such as FC, ESCON, FICON and DVB, can only be mapped into GFP-T frames, since they have higher requirements for real-time processing. In the demultiplexing direction After receiving electrical STM-16 signals from the aggregate optical module, the SDH overhead processing unit processes the overheads, checks B1, B2 and J0 bytes in the signals and then forwards the signals to the mapping unit. The mapping unit demaps the STM-16 frames into data frames and then forwards these data frames to the convergence unit. The convergence unit demultiplexes the data frames into eight electrical data signals and outputs them to corresponding tributary optical modules. Aggregate Optical Module DSA board has only one aggregate optical moudule, which allows the access of optical STM-16 signals (ITU-T G.692). In the multiplexing direction

Confidential and Proprietary Information of ZTE CORPORATION

113

ZXMP M900 (V2.20) Hardware Manual

The aggregate optical module receives the electrical STM-16 signals from the multiservice convergence unit, converts them into optical signals and finally output corresponding optical STM-16 signals in compliance with ITU-T G.692. In the demultiplexing direction The aggregate optical module receives optical STM-16 signals (ITU-T G.692) from the optical line, converts them into electrical signals and then forwards them to the multiservice convergence unit. Control and Communication Unit This unit monitors the power supply of the board and the running status of the board, and performs the supervision function of the EMS.

Front Panel: Interfaces and Indicators


The front panel of DSA board is shown in Figure 56.
FIGURE 56 FRONT PANEL OF DSA BOARD

1. Running and alarm indicators 2. Aggregate optical interface 3. Data service tributary optical interface 4. Indicator of tributary optical interface 5. Laser warning sign 6. Laser class sign

Table 59 describes the front panel and related information for basic operations of DSA board.

114

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 59 DESCRIPTIONS OF DSA BOARDS FRONT PANEL AND RELATED OPERATION INFORMATION

Board Item Board ID NOM ALM Indicator Indicator of data service tributary optical interface INn OUTn DROPn ADDn

DSA DSA Running indicator, green Alarm indicator, red

The green indicators correspond to the data service tributary optical interfaces, as shown in Figure 56.

Line input optical interface, n=1, 2, LC/PC connector Line output optical interface, n=1, 2, LC/PC connector Data service tributary optical output interface, n=1 to 8, LC/PC connector Data service tributary optical input interface, n=1 to 8, LC/PC connector Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of DSA board is CLASS 1 2

Optical interface

Laser warning sign

Laser class sign Number of occupied slot

All slots in OTU subrack


Slots for DSA board

Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8
Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Operation precautions

OTUG board should be used as the regeneration board for DSA board.

Confidential and Proprietary Information of ZTE CORPORATION

115

ZXMP M900 (V2.20) Hardware Manual

Table 60 lists the relations between the working status and corresponding indicator status of DSA board.
TABLE 60 RELATIONS BETWEEN THE WORKING STATUS AND INDICATOR STATUS OF DSA BOARD

Indicator Status Indicator of Tributary Optical Interface (Green) ON OFF

Working Status

NOM (Green)

ALM (Red)

Waiting for configuration Running normally Alarming Initializing Waiting for download Downloading status Tributary interface has no LOS alarm Tributary interface has LOS alarm

The green indicator and the red indicator flash alternately and slowly. Flashing slowly and regularly Flashing slowly and regularly ON OFF ON Flashing slowly and regularly

The green indicator and the red indicator flash quickly at the same time The green indicator and the red indicator flash slowly at the same time Flashing slowly and regularly -

Note: The - symbol means that the indicator status is indefinite.

Configuration of DSA Board


DSA board can work in either TM (Terminal Multiplexer) mode or OAD (Optical Add/Drop) mode. TM working mode In this working mode, DSA board works as a terminal multiplexer. As shown in Figure 57, bidirectional service signals are transmitted between Node A and Node B. The line optical interface 1 (STM-16_1) of node A is connected to the line optical interface 2 (STM-16_2) of node B with an optical cable.

116

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 57
STM-16_2

TM WORKING MODE OF DSA BOARD


STM-16_1 STM-16_2 STM-16_1

1 Node A 8 1

8 Node B

The transmission procedure of data service from Node A to Node B is as follows: The data service signal is input through the tributary optical interface 1 of Node A and then mapped into an STM-16 signal. The STM-16 signal is output from the line optical interface 1 (STM-16_1) of Node A and then transmitted over the optical cable. After reaching the line optical interface 2 (STM-16_2) of Node B, the data service signal is demapped from the STM-16 signal and output through the tributary optical interface 1 of Node B.

The transmission of data service from Node B to Node A is similar to the procedure described above. OAD working mode In this working mode, DSA board works as an optical add/drop multiplexer. As shown in Figure 58, bidirectional services are transmitted between Node A and Node C. Both Node A and Node C work in the TM mode while Node B works in the OAD mode.
FIGURE 58
STM-16_2

OAD WORKING MODE OF DSA BOARD


STM-16_1 STM-16_2 STM-16_1 STM-16_2 STM-16_1

1 Node A (TM) 8 1

8 Node B (OAD) 1

8 Node C (TM)

The transmission procedure of data service from Node A to Node C is as follows:


The data service signal is input through the tributary optical interface 1 of Node A and then mapped into an STM-16 signal.

Confidential and Proprietary Information of ZTE CORPORATION

117

ZXMP M900 (V2.20) Hardware Manual

The STM-16 signal is output from the line optical interface 1 of Node A and then transmitted to the line optical interface 2 of Node B over an optical cable. At Node B, the STM-16 signal is demapped to the tributary optical interface 1. Instead of being dropped at Node B, the demapped data service signal is mapped to the line optical interface 1 again through VC configuration and transmitted to the line optical interface 2 of Node C. Finally, the data service signal is demapped from STM-16 signal and output from the tributary optical interface 1 of Node C.

The transmission of data service from Node C to Node A is similar to the procedure described above.

The data service signal is input through the tributary optical interface 1 of Node C and then mapped into an STM-16 signal. The STM-16 signal is output from the line optical interface 1 of Node A and then transmitted to the line optical interface 2 of Node B over an optical cable. At Node B, the STM-16 signal is demapped to the tributary optical interface 1. Instead of being dropped at Node B, the demapped data service signal is mapped to the line optical interface 1 again through VC configuration and transmitted to the line optical interface 2 of Node A. Finally, the data service signal is demapped from STM-16 signal and output from the tributary optical interface 1 of Node A.

Configuration Notes: During the configuration of DSA board, the following items should be paid attention to: The total bandwidth of tributaries that are mapped to the same aggregate should be less than 2.5 Gbit/s. DSA board can use up to 32 VC4s or 96 VC3s. DSA board can multiplexes eight tributary signals into two STM-16 signals. The first STM-16 siganl contains VC4_1 to VC4_16 or VC3_1_1 to VC3_16_3, while the second one contains VC4_17 to VC4_32 or VC3_17_1 to VC3_32_3. Be cautious not to allocate the same data service to different STM-16 signals. For the same kind of data services, either VC4 virtual concatenation or VC3 virtual concatenation mode can be used, that is, the same kind of data services can only use the same virtual concatenation mode. However, different kinds of data services can use different virtual concatenation modes at the same time. If a DSA board acts as a TM node, one or two line optical interfaces of it can be used. But if it acts as an OAD node, both line optical interfaces must be used and in this case, a pass-through service signal needs to use two tributary optical interfaces.

118

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

The configuration of DSA board should not be limited to wavelengths. It is recommended to analyze the configuration based on data services to be accessed as a whole. The characteristic of data services is that they do not provide unidirectional services. Therefore, the transmit/receive interfaces at the client side of DSA board must be configured with the receive/transmit interfaces of user equipment in pairs.

Performance and Alarm Messages


The performance messages of DSA board are listed in Table 61.
TABLE 61 PERFORMANCE MESSAGES OF DSA BOARD

Detection Point

Item Output optical power Laser bias current

Remark Only detected when M-Z laser is used -

Aggregate transmitter

Laser temperature Inner-module temperature TEC current MZ modulator bias voltage Input optical power 15-min B1 error count 15-min B2 error count

Aggregate receiver

15-min ES 15-min SES 15-min UAS 15-min BER

Tributary receiver

Total received packet count Total received byte count 15-min received error packet ratio 15-min received error packet count 15-min 8B/10B CV Total sent GFP control frame Total sent GFP client data frame Total sent GFP client management frame Total sent GFP idle frame 15-min 8B/10B UAS 15-min received PAUSE frame Only detected for GE Only detected for GE and GFP-F

Confidential and Proprietary Information of ZTE CORPORATION

119

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Item

Remark It depends on the board configuration whether to detect these items. It depends on the board configuration whether to detect these items. Only detected for GE and GFP-F Only detected for GE signals Detected for all the signals -

Input optical power

B1 bit error ratio B2 bit error ratio Output optical power Laser bias current Inner-module temperature Total sent packets Total sent bytes 15-min sent PAUSE frame count 15-min 8B/10B CV 15-min 8B/10B UAS Total received GFP frame Total received GFP control frame Total received GFP client data frame Total received GFP client management frame Tributary transmitter Total received GFP idle frame Abandoned GFP frame Core frame header detects GFP frame with multiple byte error Core frame header detects single byte error tHEC detects GFP frame with multiple byte error tHEC detects single byte error eHEC detects GFP frame with multiple byte error eHEC detects single byte error pHEC detects GFP frame with multiple byte error GFP frame of mismatch user payload identifier GFP frame of mismatch user extensive frame header

120

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

The alarm messages of DSA board are listed in Table 62.


TABLE 62 ALARM MESSAGES OF DSA BOARD

Detection Point

Item High output power alarm Low output power alarm No output power alarm High laser bias current alarm High TEC current alarm

Remark Only detected when M-Z modulated laser is used -

Aggregate transmitter

Laser temperature offset out of limit alarm Module temperature out of limit alarm of inner module Laser failure alarm MZ modulator bias voltage out of limit alarm High input power alarm Low input power alarm No input power alarm LOF alarm UAS alarm SD alarm LOS alarm J0 Track Identifier Mismatch (TIM) alarm Receiving signal MS_AIS alarm

Aggregate receiver

15-min B1 BE out of limit alarm 15-min B2 BE out of limit alarm 15-min ES out of limit alarm 15-min SES out of limit alarm 15-min UAS out of limit alarm 24-hour B1 BE out of limit alarm 24-hour B2 BE out of limit alarm 24-hour ES out of limit alarm 24-hour SES out of limit alarm 24-hour UAS out of limit alarm LOS alarm Loss of clock alarm Loss of synchronization alarm

Confidential and Proprietary Information of ZTE CORPORATION

121

ZXMP M900 (V2.20) Hardware Manual

Detection Point Tributary receiver

Item 15-min received error packet out of limit alarm 15-min 8B/10B CV out of limit alarm 24-hour received error packet out of limit alarm 24-hour 8B/10B CV out of limit alarm High input power alarm Low input power alarm No input power alarm Low output power alarm No output power alarm High output power alarm Low output power alarm No output power alarm High laser current alarm Module temperature out of limit alarm of inner module

Remark -

It depends on the board configuration whether to detect these items.

Tributary transmitter

Laser end of lifetime alarm Laser failure alarm 15-min 8B/10B CV out of limit alarm 24-hour 8B/10B CV out of limit alarm Loss of GFP synchronization alarm Failure of GFP client signal alarm

Received aggregate clock 1 Received aggregate clock 2 Received clock from clock board in slot 8 of TMUX subrack Received clock from clock board in slot 7 of TMUX subrack Sent clock

Clock unavailable alarm Clock unavailable alarm

Clock unavailable alarm

Clock unavailable alarm

Clock unavailable alarm

122

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

The event messages of DSA board are listed in Table 63.


TABLE 63 EVENT MESSAGES OF DSA BOARD

Detection Point

Item Tributary laser shutdown automatically Tributary laser startup automatically

Remark It depends on the board configuration whether to detect these items. -

Tributary transmitter

Tributary laser APS shutdown forcibly Tributary laser APS startup forcibly SFP module unplugged SFP module plugged Aggregate laser shutdown automatically

Aggregate transmitter

Aggregate laser startup automatically Aggregate laser APS shutdown forcibly Aggregate laser APS startup forcibly

Clock circuit port

Clock switching succeeded Clock switching failed

DSAF Board
Functions
DSAF (Data Service Aggregation with FEC) board applies the Optical/Electrical/Optical (O/E/O) conversion mode to implement the multiplexing/demultiplexing between two or four channels of data service signals, such as GE, FC, ESCON, FICON and DVB-AIS, and one channel of OTU1 signal with FEC function. DSAF board acts as a board for accessing multi-services. Its aggregate optical interface is connected to an optical multiplexing/demultplexing board directly. Tributary side Provides two or four SFP optical interfaces; each of them supports the access of various client signals, such as GE, FE, ESCON, FICON and DVB-AIS etc.

Confidential and Proprietary Information of ZTE CORPORATION

123

ZXMP M900 (V2.20) Hardware Manual

Provides the capability of transmitting long GE frames with length up to 9600 bytes (not including four-byte CRC) Provides Generic Framing Procedures (GFP) function, supports both GFP-T and GFP-F mapping modes, and supports the detection of corresponding alarm/performance Supports the enabling control of tributary ports SFP module used in each tributary optical interface supports Digital Diagnosis (DD) function.

Aggregate side Implements the convergence of two/four tributary service signals, outputs OTU1 signal with the format meeting the specification in ITU-T G.709 and supports the detection of corresponding alarm/performance Supports FEC function; the frame format after FEC encoding meet the specification in ITU-T G.709 GE ports support the auto-negotiation function Supports Automatic Power ShutDown (APSD) function Supports VC-4 virtual concatenation Supports the application of fixed lasers and tunable lasers Tunable lasers applied in DSAF board supports the tuning of 40/80 channels of wavelengths in the whole C band. The channel spacing is 100 GHz when 40 channels of wavelengths are tuned; while the spacing is 50 GHz when 80 channels are tuned. DSAF board can be applied in a centralized wavelength supervision subsystem with the channel spacing at 50 GHz. For detailed information about the centralized wavelength supervision subsystem, please refer to Appendix C in this manual.

Clock function The aggregate side of DSAF board can provide reference clock Provides external clock Provides tributary reference clock

Supports the transparent transmission at physical layer for client equipment Supports tributary near/far-end loopback, backplane near/far-end loopback, aggregate near/far-end loopback for convenient fault location

According to the quantity of tributary ports and the type of allowable access services, DSAF board is divided into four types, as introduced in Table 64.

124

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 64

TYPES OF DS AF BOARD

Board Type

Tributary Quantity 2

Access Service Type GE

Encapsulation Mode GFP-T/F

Tributary Clock One tributary reference clock The number of tributary reference clock is the same as the number of accessed service type. One tributary reference clock The number of tributary reference clock is the same as the number of accessed service type.

DSAF2 (GE)

DSAF2 (multi-service)

GE, ESCON, DVB-AIS

GFP-T/F

DSAF4 (GE)

GE

GFP-T/F

DSAF4 (multi-service)

GE, ESCON, DVB-AIS

GFP-T

Operating Principle
Figure 59 illustrates the operating principle of DSAF board.
FIGURE 59 OPERATING PRINCIPLE OF DS AF BO ARD
Aggregate Side Convergence & Framing Unit

Tributary Side

Tributary Optical Module 1 Data service signals Tributary Optical Module 4

OTN Optical Module

G.692/ G.709/ G.705

Convergence/ Divergence Unit

Framing/LCAS Processing Unit

OTN/FEC Processing Unit

Control and Communication Unit

In the multiplexing direction (data service signals OTU1 signal): Two or four client data service signals (such as GE, FC, ESCON, FICON and DVB etc.) are accessed by two or four tributary optical modules. The convergence &

Confidential and Proprietary Information of ZTE CORPORATION

GFP Processing Unit

Clock Processing Unit

Local clock Clock from CSU in slot 7 Clock from CSU in slot 8

125

ZXMP M900 (V2.20) Hardware Manual

framing unit multiplexes these signals into an OTU1 signal with FEC, which is output by the OTN optical module after E/O conversion. In the demultiplexing direction (OTU1 signal data service signals): The OTN optical module receives an OTU1 signal, converts it into an electrical signal and then sends it to the convergence & framing unit. The convergence & framing unit demultplexes the signal into two or four data service signals and sends them to corresponding tributary optical modules. Each tributary optical module converts the received electrical data service signal into an optical signal and outputs it. DSAF board consists of 2/4 tributary optical modules, a convergence & framing unit, an OTN optical module, a clock processing unit and control and communication unit, as described below. Tributary Optical Module DSAF board provides two or four tributary optical modules. Each of them uses SFP module. In the multiplexing direction Each tributary optical module receives a data service signal (GE, FC, ESCON, FICON or DVB-ASI etc.), converts it into an electrical signal and then forwards it to the convergence & framing unit. In the demultiplexing direction Each tributary optical module converts the electrical signal received from the convergence & framing unit into an optical client signal (GE, FC, ESCON, FICON or DVB-ASI etc.) and then outputs it. Convergence & Framing Unit The convergence & framing unit consists of a GFP processing unit, a convergence/divergence unit, a framing/LCAS processing unit and an OTN/FEC processing unit. It completes the multiplexing/demultiplexing between 2/4 channels of data service signals and 1/2 channels of 2.5 Gbit/s signals. In the multiplexing direction The convergence & framing unit implements the procedures of GFP mapping, SDH virtual concatenation mapping, OTN mapping and FEC processing for 2/4 channels of electrical data service signals (such as GE, FC, ESCON, FICON and DVB-ASI etc.) and then outputs the multiplexed signal to the OTN optical module. Note: DSAF board supports the virtual concatenation (VC) modes VC4-xV and STS-3c-xV.

Note: GFP (Generic Framing Procedure) frames are classified into two types: GFP-T (Transparent GFP) and GFP-F (Framed GFP). GFP-T: GFP-T frames have fixed length. It is unnecessary to start processing a frame until the full frame is received. Therefore, GFP-T frames can be processed timely.

126

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

GFP-F: GFP-F frames have variable length. Only when the full frame is received, will the frame be processed.

GE data service signals can be mapped into either GFP-T frames or GFP-T frames. However, the other data service signals, such as FC, ESCON, FICON and DVB, can only be mapped into GFP-T frames, since they have higher requirements for real-time processing. In the demultiplexing direction The convergence & framing unit receives the 2.5 Gbit/s electrical signal from the OTN optical module and then implements the procedures of FEC processing, OTN demapping, SDH virtual concatenation demapping and GFP demapping. After the series of procedures, the 2.5 Gbit/s signal is demultiplexed into multiple client data signals. Finally, these client signals are sent to corresponding tributary optical modules after 8B/10B encoding. OTN Optical Module In the multiplexing direction The OTN optical module converts the 2.5 Gbit/s signal received from the convergence & framing unit into OTU1 optical signal and outputs it. In the demultiplexing direction The OTN optical module receives OTU1 optical signal, converts it into 2.5 Gbit/s electrical signal, and then sends it to the convergence & framing unit. Clock Processing Unit The clock processing unit can perform the following functions. Selects an optimal clock as the board clock from the local clock, line received clock, the clock coming from CSU board in slot 7 and the clock coming from CSU board in slot 8 of the TMUX subrack Provides the line received clock as external clock Provides tributary reference clock

Control and Communication Unit This unit monitors the power supply of the board and the running status of the board, and performs the supervision function of the EMS.

Confidential and Proprietary Information of ZTE CORPORATION

127

ZXMP M900 (V2.20) Hardware Manual

Front Panel: Interfaces and Indicators


Figure 60 shows the front panel of DSAF board.
FIGURE 60 FRONT P ANEL OF DS AF BOARD

1. Running and alarm indicators 2. Aggregate optical interface 3. Data service tributary optical interface 4. Indicator of tributary optical interface 5. Laser warning sign 6. Laser class sign

Table 65 describes the front panel and related information for basic operations of DSAF board.

128

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 65 DESCRIPTION OF DS AF BO ARDS FRONT P ANEL AND RELATED OPERAT ION INFORM ATION

Board Item Board ID NOM ALM Indicator Indicator of tributary optical interface IN OUT

DSAF DSAF2 Running indicator, green Alarm indicator, red Located beside tributary optical interface, each green indicator is used to indicate the working status of corresponding data service tributary optical interface, as shown in Figure 60 Aggregate input optical interface Aggregate output optical interface Data service tributary input optical interface DSAF4

Aggregate optical interface

ADDn Tributary optical interface DROPn

LC/PC connector n=1, 2 n=1-4

Data service tributary output optical interface LC/PC connector n=1, 2 n=1-4

Laser warning sign Laser class sign Number of occupied slot

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of DSAF board is CLASS 1 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Slots for DSAF board

Operation precautions

Table 66 lists the relations between the working status and corresponding indicator status of DSAF board.

Confidential and Proprietary Information of ZTE CORPORATION

129

ZXMP M900 (V2.20) Hardware Manual

TABLE 66 BOARD

RELATIONS BETWEEN WORKING STATUS AND INDICATOR STATUS OF DS AF

Indicator Status Working Status Indicator of Tributary Optical Interface (Green) ON OFF

NOM (Green)

ALM (Red)

Waiting for configuration Running normally Alarming Initializing Waiting for download Downloading status Tributary interface has no LOS alarm Tributary interface has LOS alarm

The green indicator and the red indicator flash alternately. Flashing slowly and regularly Flashing slowly and regularly ON OFF ON Flashing slowly and regularly

The green indicator and the red indicator flash quickly at the same time The green indicator and the red indicator flash slowly at the same time Flashing slowly and regularly -

Note: The - symbol means that the indicator status is indefinite.

Performance and Alarm Messages


The performance messages of DSAF board are listed in Table 67.
TABLE 67 PERFORM ANCE MESSAGES OF DS AF BO ARD

Detection Point

Item Output optical power

Remark Related to performance benchmark Only detected when laser TEC is used It depends on the board configuration whether to detect this item. -

Aggregate transmitter

Laser bias current Laser TEC current Laser temperature offset

Aggregate receiver

Input optical power 15-min B1 bit error count 15-min B2 bit error count

130

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item 15-min B1 BER 15-min B2 BER 15-min ES 15-min SES 15-min UAS FEC uncorrected frame count FEC corrected bit error count FEC corrected 0 bit error count FEC corrected 1 bit error count After-FEC BER Before-FEC BER 15-min OTU1 SM_BIP8 bit error count 15-min ODU1 PM_BIP8 bit error count 15-min SM_BIP8 ES 15-min SM_BIP8 SES 15-min SM_BIP8 UAS Input optical power Total received packet count

Remark Only detected when SFP module is used Only detected for GE (GFP-F) signals

Tributary receiver

Total received byte count 15-min received packet error count 15-min received packet error ratio count 15-min 8B/10B CV count Total transmitted packet count Total transmitted byte count Output optical power Only detected for GE (GFP-F) signals Not detected fro GE (GFP-T) signals yet It depends on the board configuration whether to detect these items. Only detected for GFP-T signals Frames with PTI=4 Not detected for GE (GFP-T) signals

Tributary transmitter

Laser bias current Inner-module temperature 15-min 8B/10B CV count 15-min transmitted PAUSE frame count Received GFP client management frame count

The alarm messages of DSAF board are listed in Table 68.

Confidential and Proprietary Information of ZTE CORPORATION

131

ZXMP M900 (V2.20) Hardware Manual

TABLE 68

ALARM MESSAGES OF DS AF BOARD

Detection Point

Item High output power alarm Low output power alarm No output power alarm Laser current over-threshold alarm Laser temperature offset over-threshold alarm

Remark Only detected when M-Z modulated laser is used -

Aggregate transmitter

MZ modulator bias voltage over-threshold alarm Output power over upper threshold alarm Output power below lower threshold alarm Laser end of lifetime alarm Laser failure alarm

Aggregate receiver

High input power alarm Low input power alarm No input power alarm Input power over upper threshold alarm Input power below lower threshold alarm LOF alarm Received signal MS-AIS UAS alarm SD alarm 15-min OTU1 SM BIP8 bit error over-threshold alarm 15-min before-correction bit error count over-threshold alarm 15-min after-correction bit error count over-threshold alarm 15-min ODU1 PM_BIP8 bit error over-threshold alarm 15-min OTU1 SM ES over-threshold alarm 15-min OTU1 SM SES over-threshold alarm 15-min OTU1 SM UAS over-threshold alarm 24-hour OTU1 SM ES over-threshold alarm

132

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item 24-hour OTU1 SM SES over-threshold alarm 24-hour OTU1 SM UAS over-threshold alarm 24-hour OTU1 SM BIP8 bit error over-threshold alarm 24-hour ODU1 PM BIP8 bit error over-threshold alarm 24-hour before-correction bit error over-threshold alarm 24-hour after-correction bit error over-threshold alarm 15-min TCMi BIP8 bit error over-threshold alarm 24-hour TCMi BIP8 bit error over-threshold alarm LOS alarm Loss of OTU1 frame alarm Loss of OTU1 multiframe alarm OTU1 TIM alarm ODU1 layer PM section TIM alarm OTU1 layer SM section BDI OTU1 layer SM section BEI OTU1 layer SM section BIAE OTU1 layer SM section IAE ODU1 layer PM section BDI ODU1 layer PM section BEI ODU1 AIS ODU1 LCK ODU1 OCI OPU1 PT mismatch alarm

Remark i=1-6 i=1-6 -

Tributary receiver

LOS alarm Loss of synchronization alarm Connection failure alarm 15-min received CRC error packet count over-threshold alarm 15-min 8B/10B CV count over-threshold alarm

Confidential and Proprietary Information of ZTE CORPORATION

133

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Item 15-min 8B/10B CV second count over-threshold alarm 24-hour 8B/10B CV count over-threshold alarm 24-hour received error packet count over-threshold alarm High input power alarm Low input power alarm No input power alarm High output power alarm Low output power alarm No output power alarm Laser current over-threshold alarm Inner-module temperature over-threshold alarm

Remark It depends on the board configuration whether to detect these items.

It depends on the board configuration whether to detect these items.

Tributary transmitter

Laser failure alarm Laser end of lifetime alarm GFP client signal failure alarm GFP loss of synchronization alarm 15-min 8B/10B CV count over-threshold alarm 24-hour 8B/10B CV count over-threshold alarm Pluggable module dismount alarm

Board

Board environment temperature alarm Board self-test failure alarm

The event messages of DSAF board are listed in Table 69.


TABLE 69 EVENT MESSAGES OF DS AF BOARD

Detection Point Tributary transmitter Aggregate transmitter

Item Tributary laser shutdown Tributary laser startup Aggregate laser shutdown Aggregate laser startup

134

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item Laser APS shutdown forcibly Laser APS startup forcibly Clock switching succeeded Clock switching failed

Port

MCU reset EEPROM data error Data service configuration failure Loopback configuration failure

Configuration of DSAF Board


During the configuration of DSAF board, pay attention to the following items: During the configuration of tributary services for DSAF board, it is necessary to specify the GFP data encapsulation format, the quantity and position of Virtual Container (VC) to be used. When the tributary interfaces of DSAF board are used to add/drop service signals, their properties should be set as Up/down Link (add/drop) in the EMS. When the tributary interfaces are set as Direct link (straight-through), the function performed by these interfaces is equivalent to that of far-end loopback. DSAF board can use up to 16 VC4s or 48 VC3s. For the same kind of data services, either VC4 virtual concatenation or VC3 virtual concatenation mode can be used, that is, the same kind of data services can only use the same virtual concatenation mode. However, different kinds of data services can use different virtual concatenation modes at the same time. The characteristic of data services is that they always exist in pairs. Therefore, the transmit/receive interfaces at the client side of DSA board must be configured with the receive/transmit interfaces of user equipment in pairs. There are three kinds of reference clocks available on the client side of DSAF board. The board will select different reference clock automatically according to the type of service accessed to a port. Selects 125 MHz reference clock for GE service Selects 100 MHz reference clock for ESCON service Selects 135 MHz reference clock for DVB_ASI service

Confidential and Proprietary Information of ZTE CORPORATION

135

ZXMP M900 (V2.20) Hardware Manual

DSAE Board
Functions
DSAE (Data Service Aggregation Electrical interface) board, used as a tributary board in a TMUX system, combines eight data service signals at its tributary side into four 2.5 Gbit/s signals on the backplane and implements the reverse procedure as well. The aggregate convergence board cooperating with the DSAE board is SMU board. The DSAE board provides the following functions: Tributary side Provide eight SFP optical interfaces. Each of them supports the access of various client signals, such as GE, FC, ESCON, FICON and DVB-ASI etc. The SFP module used in each tributary optical interface supports Digital Diagnosis (DD) function.

Backplane side Provide two channels on the backplane: channel A (corresponding to CSU board in slot 7 of TMUX subrack) and channel B (corresponding to CSU board in slot 8 of TMUX subrack). Each channel is able to carry four bidirectional 2.5 Gbit/s signals. Support the signal switching between channel A and channel B Select the optimal signal from two channels for input and divides one signal into two for output on the backplane.

Support the clock selection function. Support near/far-end tributary loopback and near/far-end backplane loopback for convenient fault localization. Support APS check of electric layer protection: Service signal APS check for electric layer client service 1+1 protection. Line APS check for service board redundancy 1+1 protection. APS check for line OCH 1+1 protection. Service signal APS check for two-fiber bidirectional OCH shared protection in ring network.

136

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Operating Principle
The operating principle of DSAE board is illustrated in Figure 61.
FIGURE 61
Tributary Side

OPERATING PRINCIPLE OF DSAE BOARD


Backplane Side

Convergence & Framing Unit

Tributary Optical Module 1 Data service signals Tributary Optical Module 8

Channel A Convergence/ Divergence Unit GFP Processing Unit Framing Unit 1-2 Divider/ 2-1 Selector Unit Channel B Channel A Channel B

Control and Communication Unit

Clock Processing Unit

Local clock Clock from CSU in slot 7 Clock from CSU in slot 8

In the multiplexing direction (data service signals 42.5 Gbit/s signals): Eight client data service signals (such as GE, FC, ESCON, FICON and DVB-ASI etc.) are accessed by eight tributary optical modules. The convergence & framing unit multiplexes these signals into four 2.5 Gbit/s signals, which are then divided into two groups with the same four 2.5 Gbit/s signals in each group by the 1-2 divider. These two groups of signals are output through channel A and channel B respectively on the backplane. In the demultiplexing direction (42.5 Gbit/s data service signals): The 2-1 selector chooses the better one from the two groups of 2.5 Gbit/s signals input from channel A and channel B on the backplane. Then the convergence & framing unit divides the group into eight data service signals, which are output by corresponding tributary optical modules finally. DSAE board consists of eight tributary optical modules, a convergence & framing unit, a 1-2 divider/2-1 selector unit and the control and communication unit, as described below. Tributary Optical Module DSAE board has eight tributary optical modules. Each of them uses SFP optical module. In the multiplexing direction Each tributary optical module receives a data service signal (GE, FC, ESCON, FICON or DVB-ASI etc.), converts it into an electrical signal and then forwards it to the convergence & framing unit. In the demultiplexing direction

Confidential and Proprietary Information of ZTE CORPORATION

137

ZXMP M900 (V2.20) Hardware Manual

Each tributary optical module converts the electrical signal received from the convergence & framing unit into the optical client signal (GE, FC, ESCON, FICON or DVB-ASI etc.) and then output it to corresponding user equipment. Convergence & Framing Unit The convergence & framing unit consists of a GFP processing unit, a convergence/divergence unit and a framing unit. It completes the multiplexing/demultiplexing between eight data service signals and four 2.5 Gbit/s signals. In the multiplexing direction After 8B/10B decoding, GFP mapping, VC virtual concatenation and framing, eight data service signals (GE, FC, ESCON, FICON or DVB-ASI etc.) are mapped into four 2.5 Gbit/s signals, which are then output to the 1-2 divider/2-1 selector unit. Note: DSAE board supports the virtual concatenation (VC) modes VC-4-Xv.

Note: GFP (Generic Framing Procedure) frames are classified into two types: GFP-T (Transparent GFP) and GFP-F (Framed GFP). GFP-T: GFP-T frames have fixed length. It is unnecessary to start processing a frame until the full frame is received. Therefore, GFP-T frames can be processed timely. GFP-F: GFP-F frames have variable length. Only when the full frame is received, will the frame be processed.

GE data service signals can be mapped into either GFP-T frames or GFP-T frames. However, the other data service signals, such as FC, ESCON, FICON and DVB, can only be mapped into GFP-T frames, since they have higher requirements for real-time processing. In the demultiplexing direction The unit receives four 2.5 Gbit/s signals from the 1-2 divider/2-1 selector unit and then divides them into eight data service signals. After 8B/10B encoding, these data signals are sent into corresponding tributary optical modules. 1-2 Divider/2-1 Selector Unit The 1-2 divider/2-1 selector unit supports lossless switching between channel A and channel B on the backplane. In the multiplexing direction (1-to-2 division) The 1-2 divider separates four 2.5 Gbit/s signals received from the convergence & framing unit into two same groups with each containing four 2.5 Gbit/s signals. These two groups are output through channel A and channel B on the backplane respectively. Each channel carries four 2.5 Gbit/s signals. In the demultiplexing direction (2-to-1 selection)

138

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

The 2-1 selector receives two groups of four 2.5 Gbit/s signals from channel A and channel B on the backplane, selects the better one from them and outputs it to the convergence & framing unit. Clock Processing Unit This unit selects a clock as the board clock from the local clock, the clock coming from CSU board in slot 7 and the clock coming from CSU board in slot 8 of the TMUX subrack. Control and Communication Unit This unit monitors the power supply of the board and the running status of the board, and performs the supervision function of the EMS.

Front Panel: Interfaces and Indicators


The front panel of DSAE board is shown in Figure 62.
FIGURE 62 FRONT PANEL OF DSAE BOARD

1. Running and alarm indicators 2. Data service tributary optical interface 3. Indicator of tributary optical interface 4. Laser warning sign 5. Laser class sign

Table 70 describes the front panel and related information for basic operations of DSAE board.

Confidential and Proprietary Information of ZTE CORPORATION

139

ZXMP M900 (V2.20) Hardware Manual

TABLE 70 DESCRIPTION OF DSAE BOARDS FRONT PANEL AND RELATED OPERATION INFORMATION

Board Type Item Board ID NOM Indicator ALM Optical interface indicator ADDn Optical interface DROPn

DSAE DSAE Running indicator, green Alarm indicator, red Each optical interface has a green indicator on its right side used to indicate the working status of the interface. Data service tributary optical input interface, n=1 to 8, LC/PC connector Data service tributary optical output interface, n=1 to 8, LC/PC connector Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of DSAE board is CLASS 1 1 Slots in TMUX subrack except slot 7 and 8 Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Laser warning sign

Laser class sign Number of occupied slot Slots for DSAE board

Operation precautions

Table 71 describes the relations between the working status and corresponding indicator status of DSAE board.
TABLE 71 RELATIONS OF DSAE BOARD BETWEEN THE WORKING STATUS AND INDICATOR STATUS

Indicator Status Working Status Optical Interface Indicator (Green) -

NOM (Green)

ALM (Red)

Waiting for configuration Running normally Alarming

The green indicator and the red indicator flash alternately and slowly. Flashing slowly and regularly Flashing slowly and regularly OFF ON

140

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Indicator Status Working Status Optical Interface Indicator (Green) -

NOM (Green)

ALM (Red)

Initializing

ON

Flashing slowly and regularly

Waiting for download

The green indicator and the red indicator flash quickly at the same time. The green indicator and the red indicator flash slowly at the same time. Flashing slowly and regularly -

Download status Tributary interface has no LOS alarm Tributary interface has LOS alarm

ON OFF

Note: The - symbol means that the indicator status is indefinite.

Configuration of DSAE Board


DSAE board can work in either TM (Terminal Multiplexer) mode or OAD (Optical Add/Drop) mode. TM working mode As shown in Figure 63, bidirectional services are transmitted between Node A and Node B. The aggregate optical interface of SMU board in Node A is connected to the aggregate optical interface of SMU board in Node B with an optical cable.
FIGURE 63 TM WORKING MODE OF DSAE BOARD

DSAE

C S U

S M U

S M U

C S U

DSAE

Tributary 1 Tributary 8 Node A

Tributary 1 Tributary 8 Node B

The transmission procedure of data service from Node A to Node B is as follows: i. The data service signal is input to the DSAE board in Node A through the tributary optical interface 1 of Node A. After GFP mapping in DSAE board, cross-connection in CSU board and convergence in SMU board,

Confidential and Proprietary Information of ZTE CORPORATION

141

ZXMP M900 (V2.20) Hardware Manual

the data service signal of tributary 1 is converged into an OTU2 signal for transmission over the optical cable. ii. The SMU board in Node B receives the OTU2 signal from the optical cable. After the divergence in SMU board, the cross-connection in CSU board and demultiplexing in DSAE board, the tributary data service signal is recovered and then output through the tributary optical interface 1 of Node B. The processing and transmitting procedure of the other tributaries data service signals between Node A and B is same as the procedure described above. OAD working mode In this working mode, DSAE board works as an optical add/drop multiplexer. Figure 64 illustrates the traffic configuration of DSAE board of a node working in the OAD mode.
FIGURE 64 OAD WORKING MODE OF DSAE BOARD

Backplane channel signal CSU

DSAE

Backplane channel signal CSU

Tributary 1 Tributary 8

As shown in Figure 64, the backplane channel signal from CSU board is divided into tributary signals by the DSAE board. These tributary signals are not dropped but passed through the DSAE board. Then these signals are combined into a backplane channel signal again by the DSAE board and output to CSU board.

Note: The working modes of a DSAE boards eight tributary interfaces should be configured according to actual needs. The working mode of a tributary interface can be set as either add/drop mode or pass-through mode. Once a tributary interface has been set as pass-through, this interface can not be used to add/drop traffic any longer. It is unnecessary to configure tributary optical module for a pass-through interface.

142

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Performance and Alarm Messages


The performance messages of DSAE board are listed in Table 72.
TABLE 72 PERFORMANCE MESSAGES OF DSAE BOARD

Detection Point

Item 15-min B1 error 15-min B2 error

Remark -

Backplane interface tributary 1 to 4

15-min ES 15-min SES 15-min UAS 15-min BER Total received packet count Total received byte count 15-min received error packet ratio 15-min received error packet count

Only detected for GE (GFP-F) signals

Tributary receiver

15-min 8B/10B CV 15-min 8B/10B ES 15-min 8B/10B SES 15-min 8B/10B UAS Input optical power Output optical power Laser bias current

It depends on the board configuration whether to detect these items.

Tributary transmitter

Inner-module temperature Total sent packet count Total sent byte count 15-min sent PAUSE frame count

Only detected for GE (GFP-F) signals

The alarm messages of DSAE board are listed in Table 73.


TABLE 73 ALARM MESSAGES OF DSAE BOARD

Detection Point Board Backplane interface tributary 1 to 4

Item Board environment temperature alarm LOF alarm UAS alarm SD alarm LOS alarm

Remark -

Confidential and Proprietary Information of ZTE CORPORATION

143

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Item J0 Track Identifier Mismatch (TIM) alarm Receiving signal MS_AIS alarm 15-min B1 error count out of limit alarm 15-min B2 error count out of limit alarm 15-min ES out of limit alarm 15-min SES out of limit alarm 15-min UAS out of limit alarm LOS alarm LOC alarm Loss of synchronization alarm Loss of GFP synchronization alarm Loss of VC multiframe alarm 15-min received error packet count out of limit alarm 15-min 8B/10B CV out of limit alarm 15-min 8B/10B CV ES out of limit alarm 15-min 8B/10B CV SES out of limit alarm 15-min 8B/10B CV UAS out of limit alarm 24-hour received error packet count out of limit alarm 24-hour 8B/10B CV out of limit alarm 24-hour 8B/10B CV ES out of limit alarm 24-hour 8B/10B CV SES out of limit alarm 24-hour 8B/10B CV UAS out of limit alarm High input power alarm Low input power alarm No input power alarm

Remark Only detected for GE signals Only detected for GE signals It depends on the board configuration whether to detect these items.

Tributary receiver

Tributary transmitter

High output power alarm Low output power alarm No output power alarm High laser bias current alarm

144

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item Module temperature out of limit alarm of inner module Laser end of lifetime alarm Laser failure alarm

Remark

The event messages of DSAE board are listed in Table 74.


TABLE 74 EVENT MESSAGES OF DSAE BOARD

Detection Point

Item Tributary laser shutdown Tributary laser startup

Remark It depends on the board configuration whether to detect these items. -

Tributary transmitter

Tributary laser APS shutdown forcibly Tributary laser APS startup forcibly SFP module unplugged SFP module plugged MCU reset EEPROM data error

Port

Service switching Clock switching succeeded Clock switching failed

SMU Board
Functions
SMU (SDH Multiplex Unit) board is a kind of aggregate convergence board that implements the multiplexing/ demultiplexing between STM-16 signals at backplane side and OTU2 signal at aggregate side. The tributary board cooperating with the SMU board is DSAE board. Backplane side Provides two channels on its backplane side: channel A (corresponding to CSU board in slot 7) and channel B (corresponding to CSU board in slot 8). Either of them is able to carry four bidirectional 2.5 Gbit/s signals. Supports the signal switching between channel A and channel B

Confidential and Proprietary Information of ZTE CORPORATION

145

ZXMP M900 (V2.20) Hardware Manual

Selects the optimal one from two channels of input signals and divides one channel of output signals into two same groups on the backplane. Aggregate side Supports single-channel bidirectional colored OTU2 DWDM optical interface. Provides a pair of 10.7 Gbit/s optical interfaces (IN/OUT). The output optical signal at aggregate side meets the requirements of ITU-T G.692. The input optical interface at aggregate side can receive optical signal complying with ITU-T G.692 or G.975. The service traffic carried by this pair of optical interfaces is OTU2 signal. Supports the FEC encoding/decoding function specified in ITU-T G.709. This function can be set on the EMS. Three FEC modes are optional: FEC Codec, AFEC Codec and OTN Format-No FEC. Supports the lossless switching between master and slave clock input/output interfaces, and the lossless switching between clocks on the backplane. Supports the export of clock. Either fixed laser or tuneable laser can be used at aggregate side. In case of tuneable laser, 40/80 wavelengths in the whole C band can be tuned. The wavelength spacing is 100 GHz for 40 channels while the wavelength spacing is 50 GHz for 80 channels. Supports the application in a centralized wavelength supervision subsystem with the channel spacing at 50 GHz. For detailed information about the centralized wavelength supervision subsystem, please refer to Appendix C in this manual. Supports near-end/far-end loopback at backplane side and near-end/far-end loopback at aggregate side as well, which makes troubleshooting easier. Supports the online download of board software. Implements APS monitoring for two-fiber bidirectional channel shared ring protection line at electronic layer.

146

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Operating Principle
The operating principle of SMU board is illustrated in Figure 65.
FIGURE 65 OPERATING PRINCIPLE OF SMU BOARD
Aggregate Side

Backplane Side Channel A Channel B Channel A Channel B

1-2 Divider/ 2-1 Selector Unit

Convergence /Divergence Unit

10G Optical Module

G.692

CSU in slot 7 CSU in slot 8

Clock Processing Unit

Control and Communication Unit

In the multiplexing direction (42.5 Gbit/s OTU2), the 2-1 selector receives 2.5 Gbit/s signals from channel A and channel B (each of them carrying four 2.5 Gbit/s signals) on the backplane, selects the better signals from these two channels and forwards them to the convergence unit. The convergence unit combines the four 2.5 Gbit/s signals into an electrical OTU2 signal and sends it to the 10G optical module, which converts the electrical signal into an optical one and outputs it for transmission over the optical line. In the demultiplexing direction (OTU2 42.5 Gbit/s), the 10G optical module receives an optical OTU2 signal from the aggregate side, converts it into an optical signal and outputs it to the divergence unit. The divergence unit demultiplexes this signal into four 2.5 Gbit/s signals and then the 1-2 divider separates these four 2.5 Gbit/s signals into two same groups with each of them containing the same four 2.5 Gbit/s signals and finally outputs the two groups of signals from channel A and channel B respectively at the backplane side. SMU board consists of a 1-2 divider/2-1 selector unit, a convergence/ divergence unit, a 10G optical module, a clock processing unit and a control and communication unit, as described below. 1-2 Divider/2-1 Selector Unit In the multiplexing direction (2-1 selector): The 2-1 selector receives two groups of 2.5 Gbit/s signals from channel A and channel B (each channel carries four 2.5 Gbit/s signals) on the backplane, selects the better one from these two channels and then sends them to the

Confidential and Proprietary Information of ZTE CORPORATION

147

ZXMP M900 (V2.20) Hardware Manual

convergence/divergence unit. The 1-2 divider/2-1 selector unit supports lossless switching between channel A and channel B. In the demultiplexing direction (1-2 divider): The 1-2 divider separates four 2.5 Gbit/s signals received from the convergence/divergence unit into two same groups with each containing the same four 2.5 Gbit/s signals, and then outputs the two groups of signals from channel A and channel B respectively at the backplane side. Convergence/Divergence Unit This unit implements the multiplexing/demultiplexing between four 2.5 Gbit/s signals and an OTU2 signal. In the multiplexing direction (convergence): This unit converges four 2.5 Gbit/s signals received from the 2-1 selector into an OTU2 signal (ITU-T G.709), and then sends the OTU2 signal to the 10G optical module. In the demultiplexing direction (divergence): This unit receives an OTU2 signal (ITU-T G.709) from the 10G optical module, demulplexes it into four 2.5 Gbit/s signals and then sends these signals to the 1-2 divider. 10G Optical Module In the multiplexing direction, this module converts the electrical OTU2 signal into an optical signal (10.709 Gbit/s) and then sends it out. In the demultiplexing direction, this module converts the optical signal (10.709 Gbit/s) into an electrical OTU2 signal and then sends it to the convergence/divergence unit. Clock Processing Unit The clock processing unit supports the selection of reference clock sent at aggregate side and the export of clocks. It selects the optimal clock from the following reference clock sources as the reference clock sent at aggregate side according to the optimal clock selection algorithm. Clock provided by CSU board in slot 7 Clock provided by CSU board in slot 8 Clock extracted from the input traffic at aggregate side Clocks extracted from tributaries in the current working channel on the backplane Local clock In addition, this unit exports the clock extracted from the input traffic at aggregate side to CSU board when the input traffic is normal. Control and Communication Unit This unit monitors the power supply of the board and the running status of the board, and performs the supervision function of the EMS.

148

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Front Panel: Interfaces and Indicators


The front panel of SMU board is shown in Figure 66.
FIGURE 66 FRONT PANEL OF SMU BOARD

1. Running and alarm indicators 2. Line input/output optical interface 3. Laser warning sign 4. Laser class sign

Table 75 describes the front panel and related information for basic operations of the SMU board.
TABLE 75 DESCRIPTION OF SMU BOARDS FRONT PANEL AND RELATED OPERATION INFORMATION

Board Type Item Board ID Indicator Optical interface NOM ALM IN/OUT

SMU SMU Running indicator, green Alarm indicator, red Line input/output optical interface, LC/PC connector

Confidential and Proprietary Information of ZTE CORPORATION

149

ZXMP M900 (V2.20) Hardware Manual

Board Type Item Laser warning sign Laser class sign Number of occupied slot Slots for SMU board

SMU Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of SMU board is CLASS 1 1 Slots in TMUX subrack except slot 7 and 8 Avoid damaging optical connectors plugging/unplugging the board. while

Operation precautions

Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time. Use OTUG board as the regeneration board for SMU board as needed.

Table 76 describes the relationship between the working status of SMU board and the status of indicators.
TABLE 76 RELATIONS OF SMU BOARD BETWEEN THE WORKING STATUS AND INDICATOR STATUS

Working Status Waiting for configuration Running normally Alarming Initializing Waiting for download Download status

Indicator Status NOM (Green) ALM (Red)

The green indicator and the red indicator flash slowly and alternately. Flashing slowly and regularly Flashing slowly and regularly ON OFF ON Flashing slowly and regularly

The green indicator and the red indicator flash quickly at the same time. The green indicator and the red indicator flash slowly at the same time.

Performance and Alarm Messages


The performance messages of SMU board are listed in Table 77.
TABLE 77 PERFORMANCE MESSAGES OF SMU BOARD

Detection Point Backplane interface tributary 1 to 4

Item 15-min B1 error count 15-min B2 error count 15-min ES

Remark -

150

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item 15-min SES 15-min UAS 15-min BER High input power alarm threshold 15-min FEC uncorrectable frames 15-min FEC corrected error count 15-min FEC corrected 0 error count

Remark It depends on the board configuration whether to detect this item. -

Aggregate receiver

15-min FEC corrected 1 error count 15-min after-FEC BER 15-min before-FEC BER 15-min OTU2 BIP8 error count 15-min ODU2 PM_BIP8 error count Input optical power Laser bias current

Aggregate transmitter

Laser temperature offset MZ modulator bias voltage

Board

Board environment temperature

The alarm messages of SMU board are listed in Table 78.


TABLE 78 ALARM MESSAGES OF SMU BOARD

Detection Point Board

Item Board environment temperature alarm LOF alarm UAS alarm SD alarm LOS alarm J0 TIM alarm

Remark -

Backplane interface tributary 1 to 4

Receiving signal MS_AIS alarm 15-min B1 error count out of limit alarm 15-min B2 error count out of limit alarm 15-min ES out of limit alarm 15-min SES out of limit alarm 15-min UAS out of limit alarm

Confidential and Proprietary Information of ZTE CORPORATION

151

ZXMP M900 (V2.20) Hardware Manual

Detection Point

Item High input power alarm Low input power alarm No input power alarm UAS alarm SD alarm LOS alarm LOC alarm Loss of synchronization alarm OTUk signal TIM alarm 15-min OTUk BIP8 error out of limit alarm Loss of OTUk frame alarm Loss of OTUk multiframe alarm 15-min before-correction bit error count out of limit alarm

Remark k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 k=2 Detected only for STM-64 signal -

Aggregate receiver

15-min after-correction bit error count out of limit alarm OTUk AIS alarm OTUk SM field BDI OTUk SM field BEI OTUk SM field BIAE OTUk SM field IAE ODUk PM field TIM ODUk PM field BDI ODUk PM field BEI ODUk AIS alarm ODUk LCK alarm ODUk OCI alarm OPUk PT mismatch J0 TIM alarm

Aggregate transmitter

High output power alarm Low output power alarm No output power alarm High laser bias current alarm Laser temperature offset out of limit alarm Laser end of life time alarm Laser failure alarm

152

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Detection Point

Item MZ modulator bias voltage out of limit alarm

Remark It depends on the board configuration whether to detect this item.

The event messages of SMU board are listed in Table 79.


TABLE 79 EVENT MESSAGES OF SMU BOARD

Detection Point

Item Laser shutdown automatically

Remark -

Aggregate transmitter

Laser startup automatically Laser APS shutdown forcibly Laser APS startup forcibly MCU reset

Port

EEPROM data error Clock switching succeeded Clock switching failed

Confidential and Proprietary Information of ZTE CORPORATION

153

ZXMP M900 (V2.20) Hardware Manual

Multiplex/Demultiplex Boards
Board ID SMU OCI OBM OMU VMUX ODU OAD WBU WSU WBM SDM Optical Channel Interleaver Optical Broadband Multiplexer Optical Multiplexing Unit Variable insertion loss Multiplexer Optical De-Multiplexing Unit Optical Add/Drop Board Wavelength Blocking Unit Wavelength Selective Unit Wavelength Blocking Multiplexing Board Supervisory Division Multiplexing Board OA/OTU subrack Full Name Applicable Position

OCI Board
Functions
OCI (Optical Channel Interleaver) board uses the optical interleaver to implement the interleaving multiplexing and demultiplexing of wavelength channels in C or L band. It provides the following functions: Supports the interleaving multiplexing and demultiplexing of wavelength channels in C band or C+ band with the spacing at 100 GHz as well as wavelength channels with the spacing at 50 GHz in C/C+ band. C band: 192.3 THz-196.0 THz C+ band: 191.35 THz-196.05 THz Supports the interleaving multiplexing and demultiplexing of wavelength channels in L band or L+ band with the spacing at 100 GHz as well as wavelength channels with the spacing at 50 GHz in L/L+ band. L band: 187.0 THz-190.9 THz L+ band: 186.95 THz-190.85 THz The OCI board also provides the online monitoring interface for the multiplexed output/input light of 80/96 channels.

Operating Principle
The operating principle of the OCI board is illustrated in Figure 67.

154

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 67 OPERATING PRINCIPLE OF OCI BOARD


40/48-channel multplexed optical output 1 Interleaver
DeMUX Module

40/48-channel multiplexed optical output 2

Coupler

80/96-channel multiplexed optical input

40/48-channel multiplexed optical input 1 Interleaver


MUX Module

Optical Power Monitoring Module

Input light online monitoring

40/48-channel multiplexed optical input 2

Coupler

80/96-channel multiplexed optical output

Optical Power Monitoring Module

Input light online monitoring

Control and Communication Unit

Interleaver The interleaver contains two modules: DeMUX module and MUX module. At the multiplexing end: It uses the interleaver MUX module to expand the capacity of a 40/48-channel WDM system by multiplexing two groups of channels. The frequency spacing between channels in each group is 100 GHz, and the frequency shifting between two groups is half of the spacing. After the multiplexing, the channel number is increased to 80/96 and the frequency spacing becomes 50 GHz. At the demultiplexing end: It uses the interleaver DeMUX module to separate the multiplexed signal of 80/96 channels with the spacing at 50 GHz to two groups. Each group has 40 channels with the spacing at 100 GHz, and the frequency shifting between two groups is half of the spacing.

Note: Each OCI board can only implements the multiplexing/demultiplexing of channels either in C band or in L band.

Coupler Located at the demultiplexing end and multiplexing end, the couplers split the multiplexed signal of 80/96 channels, and then send parts of the signal to the optical power monitoring module.

Optical power monitoring module

Confidential and Proprietary Information of ZTE CORPORATION

155

ZXMP M900 (V2.20) Hardware Manual

Both the multiplexing end and the demultiplexing end are configured with an optical power monitoring module to monitor the output light and input light respectively. Control and communication unit It monitors the input/output optical power of the multiplexed signal of 80/96-channel and reports it to the EMS. Moreover, it receives the control command from the EMS.

Front Panel: Interfaces and Indicators


The front panel of the OCI board is illustrated in Figure 68.
FIGURE 68 FRONT P ANEL OF OCI BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

Table 80 describes the front panel and related information for basic operation of the OCI board.

156

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 80 FRONT P ANEL DESCRIPTIONS OF OCI BOARD AND REL ATED BASIC OPERATION

Board Item Board ID Indicator


[Note]

OCI OCI

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OTU10G board is CLASS 1 Input interface for signals with the spacing at 50 GHz in C50_1/L50_1 sub-band, LC/PC connector Output interface for signals with the spacing of 100 GHz in C100_1/L100_1 sub-band, LC/PC connector Output interface for signals with the spacing of 100 GHz in C100_2/L100_2 band, LC/PC connector Output interface for signals with the spacing of 50 GHz in C50_1/L50_1 band, LC/PC connector Input interface for signals with the spacing at 100 GHz in C100_1/L100_1 band, LC/PC connector Input interface for signals with the spacing at 100 GHz in C100_2/L100_2 band, LC/PC connector Monitoring interface for output signal with the spacing at 50 GHz in C50_1/L50_1 band, LC/PC connector Monitoring interface for input signal with the spacing at 50 GHz in C50_1/L50_1 band, LC/PC connector 2 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail interface while

Laser warning sign Laser class sign R R1 R2 T T1 T2 T-MON R-MON Number of occupied slot Slots for OCI board

Optical interface

Operation Precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The relationship between the status of OCI board and corresponding status of indicators are same as that of the OTU board. Please refer to Table 1 for the detailed description.

Confidential and Proprietary Information of ZTE CORPORATION

157

ZXMP M900 (V2.20) Hardware Manual

Optical Connections of OCI Board


The OCI board is used in OTM equipment with more than 40/48 wavelengths. Figure 69 illustrates the position of OCI boards and corresponding optical connections in an 80/96-channel system.
FIGURE 69 OPTICAL CONNECTIONS OF OCI BOARDS IN AN 80/96-CHANNEL SYSTEM
OTM1 OTU . . OMU C100_1 ODU C100_1 OCI C50_1 OMU C100_2 O S C EOBA ... EOPA OCI C50_1 OTU ODU C100_1 O S C . . OTM2 OTU . .

OTU . .

OLA

DCM EOBA

VGSC

DRA

OPM

OTM1 The T1 and T2 interface on the OCI board are respectively connected to the OUT interface on the OMU (C100_1 subband) board and that on the OMU (C100_2 subband) board respectively. The T interface on the OCI board is connected to the IN interface on the EOBA board. The R1 and R2 interface on the OCI board are respectively connected to the IN interface on the ODU (C100_1 sub-band) board and that on the ODU (C100_2 sub-band) board respectively. After being amplified, the multiplexed signal is accessed to the OCI board through the R interface.

OTM2

Figure 70 illustrates the position of OCI boards and corresponding optical connection in a 160/176-channel system.

158

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 70 OPTICAL CONNECTIONS OF OCI BOARDS IN A 160/176-CHANNEL SYSTEM


OTM1 OTU . . OMU C100_1 OCI C50_1 EOBA OMU C100_2 O S C OMU L100_1 OCI L50_1 OMU L100_2 EOBA OCI L50_1 ODU L100_2 OBM (C/L) OBM (C/L) O S C ODU L100_1 DCM DRA EOPA EOBA OPM VGSC OPM DCM EOPA EOBA VGSC OCI C50_1 OTU ODU C100_2 ... . . ODU C100_1 OTM2 OTU . .

OTU . .

OTU . .

OLA

OTU . .

OTU . .

OTU . .

OTM1 The T1 interface on the OCI (C100_1) board and OCI (L100_1) board are respectively connected to the OUT interface on the OMU board. The T2 interface on the OCI (C100_1) board and OCI (L100_1) board are respectively connected to the OUT interface on the OMU board. The T interface on the OCI (C) board and OCI (L) board are respectively connected to the IN interface on the EOBA (C band) board and the EOBA (L band) board. The R1 interface on the OCI (C100_1) board and OCI (L100_1) board are respectively connected to the IN interface on the ODU board. The R2 interface on the OCI (C100_1) board and OCI (L100_1) board are respectively connected to the IN interface on the ODU board. The multiplexed signal of C band and L band is accessed to the OCI (C) board and OCI (L) board through the R interface on these two boards respectively.

OTM2

Performance and Alarm Messages


The performance and alarm messages related to the OCI board are listed in Table 81.
T AB L E 8 1 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OCI B O AR D

Type Performance Alarm

Item Output optical power of MUX signal Input optical power of DeMUX signal No output power alarm (MUX) Low output power alarm (MUX) MUX output power out of upper limit alarm

Confidential and Proprietary Information of ZTE CORPORATION

159

ZXMP M900 (V2.20) Hardware Manual

Type

Item MUX output power out of lower limit alarm No input power alarm (DeMUX)

Low input power alarm (DeMUX) DeMUX input power out of upper limit alarm DeMUX input power out of lower limit alarm Event MCU reset

OBM Board
Functions
The OBM board implements the multiplexing/demultiplexing of channels in C/L band and the supervisory channels of 1510 nm and 1625 nm. The 1510 nm supervisory channel is used to monitor signals in C band, while the 1625 nm supervisory channel is used to monitor signals in L band. The OBM board supports the online monitoring of optical power of signals in C/L band and the 1510 nm/1625 nm channel.

Operating Principle
The operating principle is illustrated in Figure 71.
FIGURE 71 OPERATING PRINCIPLE OF OBM BOARD
C-band multiplexed optical input L-band multiplexed optical input OSC input Multiplexed optical output

Coupler

Optical Power Monitoring Module

Output light online supervision

C-band multiplexed optical output L-band multiplexed optical output OSC output

Broadband Multiplexer

Coupler

Multiplexed optical input

Optical Power Monitoring Module

Input light online supervision

Control and Communication Unit

160

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Broadband multiplexer At the multiplexing end: It uses the MUX module of broadband multiplexer to expand the capacity of an 80/96-channel WDM system by multiplexing channels in C band and L band with the spacing at 50 GHz. The supervisory signal is also multiplexed at the same time. After the multiplexing, the channel number is increased to 160/176. At the demultiplexing end: It uses the DeMUX module of broadband multiplexer to separate the multiplexed signal of 160/176 channels to channels in C band and L band with the spacing at 50 GHz. There are 80/96 channels in each band after demultiplexing. The supervisory signal is also separated from the multiplex signal.

Coupler Located at the multiplexing/demultiplexing end, it separates the multiplexed signal of 160/176 channels and sends part of the optical signals to the optical power monitoring module.

Optical power monitoring module Both the multiplexing end and the demultiplexing end are configured with an optical power monitoring module to monitor the power of output light and input light respectively.

Control and communication unit It monitors the input/output optical power of the combined signal and reports it to the EMS. Moreover, it receives the control command from the EMS.

Front Panel: Interfaces and Indicators


The front panel of the OBM board is illustrated in Figure 72.

Confidential and Proprietary Information of ZTE CORPORATION

161

ZXMP M900 (V2.20) Hardware Manual

FIGURE 72 FRONT P ANEL OF OBM BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

Table 82 describes the front panel and related information for basic operation of the OCI board.
TABLE 82 FRONT PANEL DESCRIPTIONS OF OBM BOARD AND RELATED BASIC OPERATION

Board Item Board ID Indicator


[Note]

OBM OBM

NO M ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Input interface for signals in C band with the spacing at 50 GHz, LC/PC connector Input interface for signals in L band with the spacing at 50 GHz, LC/PC connector

Laser warning sign Optical interface CT LT

162

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item CST LST T MO N_T CR LR CSR LSR R MO N_R Number of occupied slot Laser classification sign Slots for OBM board

OBM Input interface for 1550 nm supervisory signal, LC/PC connector Standby input interface for supervisory channel, LC/PC connector, not used Output interface for signals (C+L+1510 nm+1625 nm), LC/PC connector Monitoring interface for output signals (C+L+1510 nm+1625 nm), LC/PC connector Output interface for signals in C band with the spacing at 50 GHz, LC/PC connector Output interface for signals in L band with the spacing at 50 GHz, LC/PC connector Output interface for supervisory signal, LC/PC connector Standby output interface for supervisory channel, LC/PC connector, not used Input interface for signals (C+L+1510 nm+1625 nm), LC/PC connector Monitoring interface for input signals (C+L+1510 nm+1625 nm), LC/PC connector 2

Indicates that the laser classification of OBM board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The relationship between the status of OBM board and corresponding status of indicators are same as that of the OTU board. Please refer to Table 31 for the detailed description.

Confidential and Proprietary Information of ZTE CORPORATION

163

ZXMP M900 (V2.20) Hardware Manual

Optical Connections of OBM Board


The OBM board is only used in 160-channel DWDM systems. Figure 73 illustrates the position and optical connections of OBM boards in a network.
FIGURE 73 OPTICAL CONNECTIONS OF OBM BOARDS
OTM1
Multiplexed signal in C band

OLA
Amplified signal in C band

OTM2
Multiplexed signal in C band

EOBA

EOPA

O S C

OBM (C/L)

OBM (C/L) OSC

OBM (C/L)

O S C

Multiplexed signal in L band

EOBA

DRA

Amplified signal in L band

DRA

EOPA

Multiplexed signal in L band

The figure above omits the multiplexing, demultiplexing and amplifying process of optical signals in C band and L band. Suppose the 1510 nm is taken as the supervisory channel. OTM1 (transmitting end) The CT interface on the OBM board is connected to the OUT interface on the EOBA board of C band, while the LT interface is connected to the OUT interface on the EOBA board of L band. The CST interface on the OBM board is connected to the output interface on the OSC board. The T interface on the OBM board is connected with the external optical cable. The CR interface on the OBM board is connected to the IN interface on the EOPA board of C band, while the LR interface is connected to the IN interface on the EOPA board of L band. The CSR interface on the OBM board is connected to the input interface on the OSC board. The optical signal is accessed to the R interface of the OBM board through the external optical cable. The CR/CT interfaces on the OBM board are connected to the OLA board of C band. The LR/LT interfaces of the OBM board are connected to the OLA board of L band.

OTM2 (receiving end)

OLA

164

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

The CSR interface on the OBM board is connected to the input interface on the OSC board, while the CST interface is connected to the output interface on the OSC board. The R/T interfaces on the OBM board are connected with optical cables of the main optical channel respectively.

Performance and Alarm Messages


The Performance and Alarm Messages of the OBM board are listed in Table 83.
T AB L E 8 3 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OBM B O AR D

Type

Item Output power Input power

Remark Detection point: output interface T Detection point: input interface R CS: C-band (1510nm) LS: L-band (1625nm) supervisory channel

Performance

CS input power CS output power LS input power LS output power No output power Low output power Output power out of upper limit alarm Output power out of lower limit alarm No input power Low input power Input power out of upper limit alarm Input power out of lower limit alarm

supervisory

channel

Detection point: output interface T

Alarm

Detection point: input interface R

Event

MCU reset

Confidential and Proprietary Information of ZTE CORPORATION

165

ZXMP M900 (V2.20) Hardware Manual

OMU Board
Functions
The OMU board mainly implements the multiplexing function and provides the interface for the online monitoring of multiplexed signal. Five kinds of OMU boards are available, OMU8, OMU16, OMU32, OMU40, OMU48 and OMU80, as described in Table 84.
TABLE 84 TYPE LIST OF OMU BOARD

Board Type Item Number multiplexed wavelength Multiplexer type of

OMU8

OMU16

OMU32

OMU40

OMU48

OMU80

16

32 Coupler, AWG, TFF C100_1 L100_1

40 AWG, TFF C100_1 C100_2 L100_1 L100_2

48

80

Coupler

Coupler

AWG

AWG

Operating wavelength

C100_1

C100_1

C100_1 C100_2

C50_1 L50_1

Note:

AWG: TFF:

Array Waveguid Grating Thin Film Filter

Operating Principle
Taking OMU80 board as example, the operating principle of the OMU board is illustrated in Figure 74.
FIGURE 74 OPERATING PRINCIPLE OF OMU BOARD

Input optical channel 1 Input optical channel 2 . . . Input optical channel 80

l1 l2 80:1 MUX l 8 0 Optical power monitoring module Online monitoring interface Multiplexed light ouput

Control and Communication Unit

166

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

The OMU board combines optical signals of different wavelengths into a single fiber through the MUX. Before the multiplexed light is output, part of it is sent to the optical power monitoring module, which provides the online monitoring interface. The optical power monitoring module reports the total output optical power to the EMS through the control and communication unit. 80:1 Multiplier Combine 80 wavelengths signals into a multiplexed signal. Coupler Separate the multiplexed signal of 160/176 channels and sends part of the optical signals to the optical power monitoring module. Optical power monitoring module Send the output optical power monitored by the monitoring module to the control and communication unit. Control and communication unit It monitors the input/output optical power of the combined signal and reports it to the EMS. Moreover, it receives the control command from the EMS.

Front Panel: Interfaces and Indicators


Taking the OMU80 board as example, Figure 75 illustrates its front panel.

Confidential and Proprietary Information of ZTE CORPORATION

167

ZXMP M900 (V2.20) Hardware Manual

FIGURE 75 FRONT P ANEL OF OMU40 BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

Table 85 describes the front panel and related information for basic operation of four types of OMU boards.
TABLE 85 FRONT PANEL DESCRIPTIONS OF OMU BOARD AND RELATED BASIC OPERATION

Board Type Item Board ID

OMU8 OMU8

OMU16 OMU16

OMU32 OMU32

OMU40 OMU40 C100_1

OMU48 OMU48

OMU80 OMU80

Sub-band Name

C100_1

C100_1

C100_1 L100_1

C100_2 L100_1 L100_2

C100_1 C100_2

C50_1 L50_1

Indicator
[Note]

NOM ALM CHn

Running indicator, green Alarm indicator, red Optical channel input interface, LC/PC connector

168

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Type Item

OMU8 n = 1-8 LC/PC

OMU16 n= 1-16 LC/PC

OMU32 n= 1-32 LC/PC

OMU40 n= 1-40 LC/PC

OMU48 n= 1-48 LC/PC

OMU80 n= 1-80 LC/PC

Line optical output interface, LC/PC connector OUT LC/PC LC/PC LC/PC LC/PC LC/PC LC/PC

Local optical monitoring interface, LC/PC connector MON LC/PC Number of occupied slot Laser warning sign Laser class sign 2 LC/PC 2 LC/PC 2 LC/PC 2 LC/PC 2 LC/PC 4

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OMU board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 6-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber pigtail connector while plugging/unplugging the board. Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. The OMU board using AWG as its multiplexer is an active board. Therefore, unplugging this kind of OMU board will cause the traffic interruption.

Slots for OMU board

Operation precautions

Note: The relationship between the status of OMU board and corresponding status of indicators are same as that of the OTU board. Please refer to Table 31 for the detailed description. C100_1 and C100_2 respectively refer to the first and the second subband in C band with the spacing at 100 GHz.

Optical Connections of OMU Board


The CHn interfaces on the OMU board are connected to line-side interfaces on OTU boards or aggregate interfaces on SRM41/SRM42/GEM/DSA boards so as to access optical signals in compliance with ITU-T G.692. When the number of wavelengths to be multiplexed in ZXWM M900 system is no more than 48, connect the OUT interface on the OMU board to the IN interface on the EOBA board, as shown in Figure 76.

Confidential and Proprietary Information of ZTE CORPORATION

169

ZXMP M900 (V2.20) Hardware Manual

FIGURE 76 OPTICAL CONNECTIONS OF OMU BOARD (W AVELENGTH NUMBER N 40)


1

OTU1

OTU2

EOBA OMU

OTUn

When the number of wavelengths to be multiplexed in ZXWM M900 system is more than 48, use OMU80 board or two OMU32/OMU40/OMU48 boards and an OCI board to complex the wavelengths. When an OMU80 board is adopted, the optical connection is illustrated as shown in Figure 76. When two OMU32/OMU40/OMU48 boards and an OCI board are adopted, connect the OUT interface on the OMU board to the IN interface on the OCI board, as shown in Figure 77.
FIGURE 77 OPTICAL CONNECTIONS OF OMU BOARD (MORE THAN 48-CHANNEL)
OTM1 OTU . . OMU C100_1 OCI C50_1 OMU C100_2 O S C EOBA OCI C50_1 OBA ODU C100_2 ODU C100_1 ... EOPA OTM2 OTU . .

OTU . .

OLA

DCM

OTU . .

O S C

Performance and Alarm Messages


The Performance and Alarm Messages of the OMU board are listed in Table 86.
T AB L E 8 6 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F O M U B O AR D

Type

Item Output power

Remark Only for OMU boards with AWG -

Performance

AWG operating temperature AWG heater consumption

Alarm

No output power alarm Low output power alarm

170

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Type

Item Output power out of upper limit alarm Output power out of lower limit alarm AWG temperature out of limit alarm

Remark Only for OMU boards with AWG -

Event

MCU reset

VMUX Board
Functions
The VMUX board provides the following functions. Multiplexing function based on channel power pre-equalization: It adopts the AWG/TFF and Variable Optical Attenuator (VOA) technology to adjust the attenuation of each channel before multiplexing. It supports the multiplexing of 40/48 wavelengths in C band and 40 wavelengths in L band. Power monitoring function: It monitors the optical power of the output multiplexed signal. Channel power control and adjustment function: Cooperating with the OPM board and the ZXONM E300, the VMUX board can adjust the power of a single channel or adjust the power of all channels at the same time. The adjustment precision is 0.1 dB. The adjustable range is from 0 to 10 dB. And the intrinsic insertion loss is no more than 8 dB. The following three ways can be used to control the adjustment of channel power: The OPM board detects the power feedback at the transmitting end of the board from the MON interface on the VMUX/EOBA board or the MON_T interface on the OBM board. Adjust the channel power manually in the ZXONM E300. The OPM board detects the power feedback at the receiving end of the board from the MON interface on the ODU/OPA/OBA board or the MON_R interface on the OBM board. Adjust the channel power manually in the ZXONM E300. The OCH layer power management subsystem controls the power adjustment automatically. It queries the optical channel power at the receiving end, and then adjusts the VMUX board at the transmitting end automatically.

The VMUX board adopts AWG/TFF as its multiplexer. In terms of the wavelength range of channel signals, the VMUX board can be divided into C100_1 sub-band, C100_2 subband, L100_1 sub-band and L100_2 subband VMUX board.

Confidential and Proprietary Information of ZTE CORPORATION

171

ZXMP M900 (V2.20) Hardware Manual

Operating Principle
The operating principle of the VMUX board is illustrated in Figure 78.
FIGURE 78 OPERATING PRINCIPLE OF VMUX BOARD

The VMUX uses the temperature control circuit to drive the VOA of each channel, which will adjust the attenuation of each channel and then combine all the channels into a single channel of signal for output. The VOAs, AWG and the temperature control and drive circuit are all located in the optical module of the VMUX board. The control and communication unit sends the VOA adjustment command of each channel, and queries the performance and alarm information of the optical module in the board. The function of each unit shown in Figure 78 is described as follows. VOA Each channel is equipped with a VOA, which is controlled by the VOA control circuit part of the temperature control and drive circuit. AWG/TFF It is a kind of multiplexer adopted by the VMUX board, which implements the multiplexing function for different optical signals. Temperature control and drive circuit It includes two parts, the temperature control circuit and the VOA drive circuit, controlling the VOA of each channel and the AWG respectively. Coupler It receives the multiplexed optical signal from the AWG, outputs part of the optical signal and then sends the rest to the optical power monitoring module.

172

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Optical power monitoring module It provides the online monitoring interface, and reports the detected output optical power to the control and communication unit.

Control and communication unit It monitors the power of the output combined optical signal and reports it to the EMS, and receives commands from the EMS.

Front Panel: Interfaces and Indicators


The front panel of the VMUX40 board is illustrated in Figure 79.
FIGURE 79 FRONT P ANEL OF VMUX BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

Table 87 describes the front panel and related information for basic operation of the VMUX board.

Confidential and Proprietary Information of ZTE CORPORATION

173

ZXMP M900 (V2.20) Hardware Manual

TABLE 87 FRONT P ANEL DESCRIPTIONS OF VMUX BOARD AND RELATED BASIC OPERATION

Board Item Board ID

VMUX VMUX40 C100_1 C100_2 L100_1 L100_2 Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Optical channel input interface, n = 1-40, LC/PC connector Optical channel input interface, n = 1-48, LC/PC connector VMUX48 C100_1 C100_2

Subband Name

Indicator
[Note]

NOM ALM

Laser warning sign

CHn Optical interface OUT MON Number of occupied slot Laser class sign Slots for VMUX board

Line optical output interface, LC/PC connector Local optical monitoring interface, LC/PC connector 2 Indicates that the laser class of VMUX is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The relationship between the status of VMUX board and corresponding status of indicators are same as that of the OTU board. Please refer to Table 31 for the detailed description. C100_1 and C100_2 respectively refer to the first and the second subband in C band with the spacing at 100 GHz.

Optical Connections of VMUX Board


The VMUX board is usually used at the transmitting end of OTM equipment in ultra long-haul 40/48-channel or 80/96-channel systems without regenerator. Taking an 80/96-channel system as example, Figure 80 illustrates the position and optical connections of the VMUX boards in the system.

174

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 80 OPTICAL CONNECTIONS OF VMUX BOARD


OTM OTU . . VMUX C100_1 OCI C50_1 VMUX C100_2 O S C EOBA OPM

OTU . .

OLA

...

OTM

The CHn interface of VMUX board is connected to the line side interface of OTU series board, or the aggregate interface of convergence boards (such as SRM41/SRM42/GEM/DSA boards). The multiplexed optical signal is output from the OUT interface of VMUX board. The VMUX should be used with the OPM board together. It can adjust the power spectrum slope of each channel through the EMS according to the monitored optical power from the OPM board.

Performance and Alarm Messages


The performance and alarm messages of the VMUX board are listed in Table 88.
T AB L E 8 8 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F VM UX B O AR D

Type

Item MUX output power

Performance

Optical attenuator value AWG operating temperature AWG heater consumption No output power alarm Low output power alarm

Alarm

Output power out of upper limit alarm Output power out of lower limit alarm AWG temperature out of limit alarm

Event

Channel attenuation adjustment failure MCU reset

Confidential and Proprietary Information of ZTE CORPORATION

175

ZXMP M900 (V2.20) Hardware Manual

ODU Board
Functions
The ODU board implements the demultiplexing of wavelengths and provides an interface special for online monitoring of multiplexed optical signal. Four types of ODU boards are available, ODU8, ODU16, ODU32, ODU40, ODU48 and ODU80, as described in Table 89.
TABLE 89 TYPE LIST OF ODU BOARD

Board Type Item Demultiplexing Number Multiplexer type

ODU8 8 TFF

ODU16 16 TFF

ODU32 32 AWG, TFF C100_1 L100_1

ODU40 40 AWG, TFF C100_1 C100_2 L100_1 L100_2

ODU48 48 AWG C100_1 C100_2

ODU80 80 AWG C50_1 L50_1

Operating wavelength

C100_1

C100_1

Note:

AWG: TFF:

Array Waveguid Grating Thin Film Filter

Operating Principle
Taking the ODU80 as example, Figure 81 illustrates the operating principle of ODU board.
FIGURE 81 OPERATING PRINCIPLE OF ODU BOARD

?1
Multiplexed optical signal input

Optical channel output 1 Optical channel output 2

?2
1:80 DeMUX

? 80
Optical channel output 80 Online monitoring interface

Optical Power Monitoring Module

Control and Communication Unit

The DeMUX in the ODU board separates optical signals of different channels in a single fiber and then sends them to corresponding optical receivers.

176

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Before the multiplexed optical signal enters the DeMUX, part of the signal is sent to the optical power monitoring module, which provides a monitoring interface for online supervision. The optical power monitoring module reports the total input optical power to the EMS through the control and communication unit. 80:1 Multiplier Combine 80 wavelengths signals into a multiplexed signal. Coupler Separate the multiplexed signal of 160/176 channels and sends part of the optical signals to the optical power monitoring module. Optical power monitoring module Send the output optical power monitored by the monitoring module to the control and communication unit. Control and communication unit It monitors the input/output optical power of the combined signal and reports it to the EMS. Moreover, it receives the control command from the EMS.

Front Panel: Interfaces and Indicators


Taking the ODU80 board as example, Figure 82 illustrates its front panel.

Confidential and Proprietary Information of ZTE CORPORATION

177

ZXMP M900 (V2.20) Hardware Manual

FIGURE 82 FRONT P ANEL OF ODU BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

Table 90 describes the front panel and related information for basic operation of four types of ODU boards.
TABLE 90 FRONT P ANEL DESCRIPTIONS OF ODU BOARD AND RELATED BASIC OPERATION

Board Type Item Board ID

ODU8 ODU8

ODU16 ODU16

ODU32 ODU32 C100_1 L100_1

ODU40 ODU40 C100_1 C100_2 L100_1 L100_2

ODU48 ODU48 C100_1 C100_2

ODU80 ODU80 C50_1 L50_1

Subband Name

C100_1

C100_1

Indicator
[Note]

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes.

Laser warning sign

Laser class sign

Indicates that the laser class of ODU board is CLASS 1

178

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Type Item

ODU8

ODU16

ODU32

ODU40

ODU48

ODU80

Optical channel output interface CHn Optical interface n = 1-8 LC/PC OUT n = 1-16 LC/PC n = 1-32 LC/PC n = 1-40 LC/PC n= 1-48 LC/PC n= 1-80 LC/PC

Optical line input interface LC/PC LC/PC LC/PC LC/PC LC/PC LC/PC

MON Number of occupied slot Slots for ODU board

Local optical monitoring interface LC/PC 2 LC/PC 2 LC/PC 2 LC/PC 2 LC/PC 2 LC/PC 4

All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. The ODU board using AWG as its multiplexer is an active board. Therefore, unplugging this kind of ODU board will cause the traffic interruption.

Note: The relationship between the status of ODU board and corresponding status of indicators are same as that of the OTU board. Please refer to Table 31 for the detailed description.

Optical Connections of ODU Board


The ODU board is usually equipped at the receiving end of OTM equipment. The output optical signals from CHn interfaces meet the wavelength requirements specified in ITU-T G.692. The output signals can be output to user equipment directly, or sent to line-side interfaces on OTU series boards or aggregate interfaces of convergence boards (such as SRM41/SRM42/GEM/DSA boards) firstly. And then the signals will be forwarded to user equipment via client-side interfaces or tributary interfaces on these boards. In the system with no more than 48 wavelengths, the amplified signal on the main optical channel is directly accessed to the IN interface of the ODU board. Suppose the signal is amplified by an EOPA board. Figure 83 illustrates the optical connection of the ODU board.

Confidential and Proprietary Information of ZTE CORPORATION

179

ZXMP M900 (V2.20) Hardware Manual

FIGURE 83 OPTICAL CONNECTION OF ODU BOARD (W AVELENGTH NUMBER N 40)

OTU1 OUT2

?1 ?2 ?n
O D U EOPA

OTUn

In a system with more than 48 wavelengths, use an ODU80 board, or two ODU32/ODU40/ODU48 boards and an OCI board to split optical wavelength. When using an ODU80 board, the optical connection of ODU80 board is illustrated in Figure 83. When using two ODU32/ODU40/ODU48 boards and an OCI board, the IN interface on the ODU board is connected to the R1 or R2 interface on the OCI board, as shown in Figure 77.

Performance and Alarm Messages


The Performance and Alarm Messages of the ODU board are listed in Table 91.
T AB L E 9 1 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F ODU B O AR D

Type

Item Input power

Remark Only for ODU boards with AWG Only for ODU boards with AWG -

Performance

AWG operating temperature AWG heater consumption No output power alarm Low output power alarm Input power out of upper limit alarm Input power out of lower limit alarm AWG temperature out of limit alarm

Alarm

Event

MCU reset

180

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

OAD Board
Functions
The OAD board implements the add/drop multiplexing function by adding/dropping 4 or 8 fixed wavelengths and then combining the local added signals with other wavelengths. The fixed wavelengths to be added/dropped are determined according to the customers requirements. Moreover, the OAD board can supervise the optical power of the added/dropped signals.

Operating Principle
Taking the OAD8 as example, Figure 84 illustrates the operating principle of the OAD board.
FIGURE 84 OPERATING PRINCIPLE OF OAD BOARD (8 W AVELENGTHS)

Control and Communication Unit IN OUT

OADM

Optical Power Monitoring Module

DROP

ADD

The OAD board is mainly composed of the Optical Add/Drop Multiplexer (OADM), the optical power monitoring module and the control and communication unit. OADM It adopts optical modules to add/drop the specified wavelengths, multiplex them and forward other wavelengths through. Optical power monitoring module It monitors the optical power of added/dropped signals and reports the measured power value to the control and communication unit. Control and communication unit It reports the power value received from the optical power monitoring module to the EMS, and receives control commands from the EMS.

Confidential and Proprietary Information of ZTE CORPORATION

181

ZXMP M900 (V2.20) Hardware Manual

Front Panel: Interfaces and Indicators


Taking the OAD8 as example, Figure 85 illustrates the front panel.
FIGURE 85 FRONT P ANEL OF O AD8 BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

182

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Table 92 describes the front panel and related information for basic operation of two types of OAD boards.
TABLE 92 FRONT P ANEL DESCRIPTIONS OF O AD BOARD AND RELATED BASIC OPERATION

Board Type Item Board ID Indicator


[Note]

OAD4 OAD4

OAD8 OAD8

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Optical drop interface, LC/PC n = 1-4 n = 1-8

Laser warning sign

Dn

An Optical interface M1 M2 IN OUT Number of occupied slot Laser warning sign Laser class sign Slots for OAD board

Optical add interface, LC/PC connector n = 1-4 n = 1-8

Mid1 interface for pass-through signal, LC/PC connector Mid2 interface for pass-through signal, LC/PC connector Input interface for multiplexed signal, LC/PC interface Output interface for multiplexed signal, LC/PC connector 2 2

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OAD board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. To ensure the gain flatness of each channel while the signal is output from the OUT interface on the OAD board, calculate the attenuation of each channel according to actual situations and add appropriate attenuators between the M1 interface and the M2 interface, and before An interfaces.

Note: The relationship between the status of OAD board and corresponding status of indicators are same as that of the OTU board. Please refer to Table 31for the detailed description.

Confidential and Proprietary Information of ZTE CORPORATION

183

ZXMP M900 (V2.20) Hardware Manual

Optical Connections of OAD Board


The OAD board is usually equipped in OADM equipment. Taking unidirectional 8-channel OADM equipment as example, Figure 86 illustrates the optical connections of the OAD8 board.
FIGURE 86 OPTICAL CONNECTIONS OF OAD8 BOARD
EOPA ?1 ?2

Optical line input from upstream site

OTU1 OTU2 . . . OTU8

?OSC OPM OSCL

?8 O A D ?1 ?2

OTU1 OTU2 . . . OTU8

?OSC

Optical line output to downstream site

EOBA

?8

The output optical signals from Dn interfaces meet the wavelength requirements of G.692, which can be directly output to user equipment. These signals can also be sent to line-side interfaces on OTU boards or aggregate interfaces of convergence boards (such as SRM41/SRM42/GEM/DSA boards) firstly. And then the signals will be forwarded to user equipment via client-side interfaces or tributary interfaces on these boards. Optical signals meeting the G.692 requirements, which are output by OTU boards or convergence boards (such as SRM41/SRM42/ GEM/DSA boards), are accessed to the OAD board through the An interfaces. When there is only one OAD board, connect the M1 interface to the M2 interface. If two OAD boards are cascaded to get more add/drop channels, connect the M1 interface on the first OAD board to the IN interface on the second one, and connect the M2 interface on the first board to the OUT interface on the second. Each OAD board only supports the signal receiving and sending in one direction, that is, the IN interface is connected to the upstream site while the OUT interface is connected to the downstream site. IN interface: Connected to the OUT interface on the OPA board. The external optical signal is accessed to the OAD board after being amplified. OUT interface: Connected to the IN interface on the OBA board.

184

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Performance and Alarm Messages


The Performance and Alarm Messages of the OAD board are listed in Table 93.
T AB L E 9 3 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OAD B O AR D

Type Performance Alarm Event

Item Channel add/drop optical power No add/drop optical power alarm Low add/drop optical power alarm -

WBU Board
Functions
WBU (Wavelength Blocking Unit) board is configured in an ROADM (Reconfigurable Optical Add/Drop Multiplexer) subsystem to implement the configuration of add/drop wavelengths. With the application of WBU board, the maintenance of existing system becomes convenient when the add/drop wavelengths change. The main funtions of WBU board includes: Supports Wavelength Blocking (WB) modules with two frequency spacings, 50 GHz and 100 GHz. Supports blocking any wavelength Provides the function of channel power equalization Provides the function of spectrum justification

Operating Principle
According to different main optical elements cofigured on the board, WBU board can be classified into three different board types, as listed in Table 94.

Confidential and Proprietary Information of ZTE CORPORATION

185

ZXMP M900 (V2.20) Hardware Manual

TABLE 94 WBU BOARD TYPE

WBU Type

Board

Add Port

Drop Port

Application Status


WBU/AD1 1 1

1. Supports 40/48 add and 40/48 drop (the frequency spacing is 100GHz) 2. Supports 80/96 add and 80/96 drop (the frequency spacing is 50GHz) 1. Supports 40/48 add and 40/48 drop (the frequency spacing is 100GHz) 2. Supports 80/96 add and 80/96 drop (the frequency spacing is 50GHz)

WBU/AD2

WBU/DGE

It does not support adding/dropping of the wavelength, but it supports the dynamic gain equalization for the pass-through wavelength.

Operating Principle of WBU/AD1 and WBU/AD2


The operating principle of WBU/AD1 board is similar to that of WBU/AD2 board. Taking WBU/AD2 board for example, Figure 87 illustrates its operating principle.
FIGURE 87 OPERATING PRINCIPLE OF WBU/AD2 BOARD

For the optical signal in direction A, after the line signal is input to the WBU board, two couplers separate two specified wavelengths (Drop1/Drop2) respectively from the appointed signal and drop them. For the optical signal in direction B, after the line signal is input to the WBU board, the WB module blocks and equalizes the power of dropped wavelengths in the pass-through signal. Finally, the processed pass-through wavelengths are combined with two added wavelengths via two couplers and then the combined signal is output as the line signal. The WBU board consists of a WB module, couplers and the control & communication unit.

186

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

WB module The WB module blocks the dropped wavelengths. On the other hand, it equalizes the power of pass-through wavelengths by applying spectrum adjustment.

Coupler It extracts or composes optical signal according to a specified coupled power proportion.

Control and communication unit It sends adjustment command to the WB module, reads the status of the WB module, communicates with the NCPF board and APSF, and accepts the commands from the EMS.

Operating Principle of WBU/DGE


The operating principle of WBU/DGE board shows in Figure 88. WBU/DGE board does not support wavelength adding/dropping, but it dynamically equalizes gain in the pass-through signal. The functional modules shown in Figure 88 are same as those in WBU/AD2 board, as described above.
FIGURE 88 OPERATING PRINCIPLE OF WBU/DGE BOARD

Front Panel: Interfaces and Indicators


The front panel of WBU board is shown in Figure 89.

Confidential and Proprietary Information of ZTE CORPORATION

187

ZXMP M900 (V2.20) Hardware Manual

FIGURE 89

FRONT PANEL OF WBU BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

Table 95 describes the front panel and related information for basic operations of the WBU board.
TABLE 95 FRONT PANEL DESCRIPTIONS OF WBU BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID Indicator Optical interface NOM ALM A1 A2 D1

WBU/AD1, WBU/AD2, WBU/DGE WBU Running indicator, green Alarm indicator, red Optical add interface 1, LC/PC connector Optical add interface 2, LC/PC connector Optical drop interface 1, LC/PC connector

188

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item D2 EXIN EXOUT IN OUT MON Laser warning sign Laser class sign Number of occupied slot

WBU/AD1, WBU/AD2, WBU/DGE Optical drop interface 2, LC/PC connector Pass-through optical input interface, LC/PC connector Pass-through optical output interface, LC/PC connector Line input optical interface, LC/PC connector Line output optical interface, LC/PC connector Local monitoring output interface, LC/PC connector Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of WBU board is CLASS 1 2


Slots for board

All slots in OTU subrack Slots in OA subrack except slot 6-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Operation precautions

Note: The relations between the working status and corresponding indicator status of WBU board are same as those of OTU board.

Optical Connections of WBU Board


WBU board is used in an ROADM subsystem. Taking WBU/AD2 board for example, Figure 90 shows the optical connections.

Confidential and Proprietary Information of ZTE CORPORATION

189

ZXMP M900 (V2.20) Hardware Manual

FIGURE 90

OPTICAL CONNECTIONS OF WBU/AD2 BAORD

As shown in Figure 90, each WBU board only supports the transceiving of signals in one optical direction. The IN/OUT interface of WBU board is connected to site in the direction A or direction B. The following describes the connection of WBU boards interfaces. IN: It is connected to the OUT interface of EOPA board for accessing the amplified aggregate optical signal. OUT: It is connected to the IN interface of EOBA board to output aggregate optical signal. D1/D2: It is connected to the IN interfaces of ODU board. The optical signals output from CHn interfaces of ODU board meet the wavelength requirements specified in ITU-T G.692. These signals can be output to user equipment directly, or output to line interface of OTU series boards or aggregate interface of convergence boards (such as SRM/GEM/DSA boards) first and then forwarded to user equipment through the client interfaces of these boards. A1/A2: It is connected to the OUT interface of OMU board. The CHn interfaces of OMU board is connected to line interfaces of OTU series board or aggregate interface of convergence boards (such as SRM/GEM/DSA boards) for accessing optical signals meeting the requirements of ITU-T G.692. Various optical multiplexing/demultiplexing boards can be connected to WBU board, such as OMU8, OMU16, OMU32, OMU40, OMU48, OMU80, OMU96, OCI, ODU8, ODU16, ODU32 ODU40, ODU48, ODU80, ODU96 and OCI. Each WBU board supports the adding/dropping of up to 40/80 or 48/96 wavelengths. EXIN and EXOUT interfaces of WBU board at A side are connected to EXOUT and EXIN interface of WBU board at B side respectively.

190

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Performance and Alarm Messages


The performance, alarm and event messages of the WBU board are listed in Table 96.
TABLE 96 PERFORMANCE, ALARM AND EVENT MESSAGES OF WBU BOARD

Type Performance

Item Board environment temperature Optical channel attenuation Board environment temperature alarm WB module failure alarm MCU reset

Alarm

Event

EEPROM data error Channel attenuation adjustment failure

WSU Board
Functions
WSU (Wavelength Selective Unit) board is configured in an ROADM (Reconfigurable Optical Add/Drop Multiplexer) subsystem to implement the reconfiguration of add/drop wavelengths. With the application of WBU board, the maintenance of existing system becomes convenient when the add/drop wavelengths change. WSU board offers the following main functions: Supports assigning any wavelength to any port Supports blocking any wavelength Supports equalizing channel power Supports adjusting specturm

Operating Principle
Six types of WSU boards are available according to different main optical components used in the board, as described in Table 97.

Confidential and Proprietary Information of ZTE CORPORATION

191

ZXMP M900 (V2.20) Hardware Manual

TABLE 97

TYPES OF WSU BOARD

Board Type

Panel Type

Add Channel Number 1

Drop Channel Number 8

Application WSUD/MA1 supports the adding/dropping of 40 wavelengths. WSUD/MA2 supports the adding/dropping of 40 wavelengths. Using as the extension board for upgrade, it has no adding optical interface and local monitoring output interface. WSUA/MD1 board is used in networks that need broadcast function. It supports the adding/dropping of 40 channels of fixed wavelengths or 40 assinged wavelengths. WSUA/MD2 board is used in networks that need broadcast function. It supports the adding/dropping of 40 channels of fixed wavelengths or 40 assinged wavelengths. Using as the extension board for upgrade, it has no dropping optical interface.

WSUD/MA1

WSUD/MA2

WSUD

WSUD/E

WSUA/MD1

WSUD WSUA/MD2 8 2

WSUA/E

Operating Principle of WSUD/MA1 and WSUD/MA2


With the similar operating principle, only the channel numbers of optical adding/dropping between WSUD/MA1 and WSUD/MA2 are different. Taking a WSUD/MA2 board for example, the operating principle is described in Figure 91.

192

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 91 OPERATING PRINCIPLE OF WSUD/MA2 BOARD

After the line signal in direction A is input to the WSU board, the WSS module outputs two dropped signals with specified wavelengths. At the same time, the WSS module equalizes the power of pass-through signals and outputs the signals through pass-through interface. For the pass-through signal in direction B, after the optical signal is input to the WSU board, the processed pass-through wavelengths are combined with two added wavelengths via two couplers and then the combined signal is output as the line signal. WSU board is comprised of WSS module, coupler and control and communication unit. WSS module: it supports the assignment and adjustment function from any wavelength to any port, and it equalizes the power by adjusting spectrum. Coupler It extracts or composes optical signal according to a specified coupled power proportion. Control and communication unit It sends adjustment command to the WSS module, reads the status of the WSS module, communicates with the NCPF board and APSF, and accepts the commands from the EMS.

Confidential and Proprietary Information of ZTE CORPORATION

193

ZXMP M900 (V2.20) Hardware Manual

Operating Principle of WSUD/E Board


Applied as the extension board for upgrade, WSUD/E board has no optical added interface and local output monitoring interface. The operating principle of the WSUD/E board is described in Figure 92. The unit functions of WSUD/E board are the same as those of WSUD/MA2.
FIGURE 92 OPERATING PRINCIPLE OF WSUD/E BOARD

Drop 1

Drop 2

Drop 9

Optical Input

WSS Module

Control and Communication Unit

Operating Principle of WSUA/MD1 and WSUA/MD2 Board


With the similar operating principle, only the channel numbers of optical adding/dropping between WSUA/MD1 and WSUA/MD2 are different. Taking a WSUA/MD2 board for example, the operating principle is described in Figure 93. The unit functions of WSUA/MD1 and WSUA/MD2 board are the same as those of WSUD/MA2.

194

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 93 OPERATING PRINCIPLE OF WSUA/MD2 BOARD

Operating Principle of WSUA/E Board


Applied as the extension board for upgrade, WSUA/E board has no optical added interface. The operating principle of the WSUA/E board is described in Figure 94. The functions of WSUA/E board are the same as those of WSUD/MA2.
FIGURE 94 OPERATING PRINCIPLE OF WSUA/E BOARD

Confidential and Proprietary Information of ZTE CORPORATION

195

ZXMP M900 (V2.20) Hardware Manual

Front Panel: Interfaces and Indicators


The front panel of WSU board varies depending on its type, WSUA or WSUD. Two kinds of front panels are similar except optical interfaces identifiers, as shown in Figure 95.
FIGURE 95 FRONT PANEL OF WSU BOARD

WSUA

WSUD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

196

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Table 98 describes the front panel and related information for basic operations of WSU board.
TABLE 98 FRONT PANEL DESCRIPTIONS OF WSU BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

WSUA/MD1, WSUA/MD2, WSUA/E WSUA

WSUD/MA1, WSUD/MA2, WSUD/E WSUD

NOM ALM An Dn EXIN EXOUT

Running indicator, green Alarm indicator, red Optical add interface, n=1-8, LC/PC connector Optical drop interface, n=1-2, LC/PC connector Optical add interface, n=1-2, LC/PC connector Optical drop interface, n=1-8, LC/PC connector

Pass-through input optical interface, LC/PC connector Pass-throuhg output optical interface, LC/PC connector -

Optical interface

IN OUT

Line input optical interface, LC/PC connector Line output optical interface, LC/PC connector Line output optical interface, LC/PC connector

OUT/D9

It acts as the optical drop interface 9 when the board is used as an extension board.

MON Laser warning sign Laser class sign Number of occupied slot

Local monitoring output optical interface, LC/PC connector Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of WSU board is CLASS 1 2


Slots for board

All slots in OTU subrack Slots in OA subrack except slot 6-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Operation precautions

Note: The relations between the working status and corresponding indicator status of WSU board are same as those of OTU board.

Confidential and Proprietary Information of ZTE CORPORATION

197

ZXMP M900 (V2.20) Hardware Manual

Optical Connections of WSU Board


WSU board is used in an ROAMD subsystem. Take WSUD/MA2 board as example. Figure 96 shows the optical connections of two WSUD boards.
FIGURE 96 OPTCIAL CONNECTIONS OF WSUD/MA2 BOARD

As shown in Figure 96, each WSU board only supports the transceiving of optical signals in one optical direction. The IN/OUT interface of WSU board is connected to site A or site B. The following describes the connection of WSU boards interfaces. IN: It is connected to the OUT interface of EOPA board for accessing the amplified aggregate optical signal. OUT: It is connected to the IN interface of EOBA board to output aggregate optical signal. Dn: Dn interfaces are connected to line interfaces of OTU series boards or aggregate interface of convergence boards (such as SRM/GEM/DSA boards). Then the needed optical signals are output from the client interfaces or tributary interfaces of these boards to user equipment. A1/A2: optical add interface. A1/A2 interfaces are connected to the OUT interface of OMU board. The CHn interfaces of OMU board are connected to line interfaces of OTU series boards or aggregate interfaces of convergence boards (such as SRM/GEM/DSA boards) so as to access optical signals meeting ITU-T G.692 requirements. EXIN/EXOUT interfaces of WSUD board at side A are respectively connected to EXIN/EXOUT interfaces at side B.

198

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

If extension WSUD boards are used for system expansion, connect a Dn interface of the WSUD/MA2 board to the IN interface of a WSUD/e board. The optical connections are showed in Figure 97.
FIGURE 97 BOARDS) OPTICAL CONNECTIONS OF WSUD/MA2 BOARD (WITH WSUA/E

In the case that service broadcast function is needed together with the add/drop configuration and port assignment functions, WSUA board should be configured instead. The configuration of WSU board is flexible. The adding/dropping of 8, 16, 24, 32 and 40 wavelengths can be implemented by configuring different interfaces of WSU board.

Confidential and Proprietary Information of ZTE CORPORATION

199

ZXMP M900 (V2.20) Hardware Manual

Performance and Alarm Messages


The performance, alarm and event messages of WSU board are listed in Table 99.
TABLE 99 PERFORMANCE, ALARM AND EVENT MESSAGES OF WSU BOARD

Type Performance

Item Board environment temperature Optical channel attenuation Board environment temperature alarm WSS module failure alarm MCU reset

Alarm

Event

EEPROM data error Channel attenuation adjustment failure

WBM Board
Functions
WBM (Wavelength Blocking Multiplexing) board is configured in a Reconfigurable Optical Add/Drop Multiplexer (ROADM) subsystem to implement the reconfiguration of add/drop wavelengths. With the application of WBU board, the maintenance of existing system becomes convenient when the add/drop wavelengths change. WBM provides the following functions: Supports the configuration of wavelengths with the spacing at 100 GHz, adding wavelengths from 1 to 40 channels or passing wavelengths through Divides the multiplexed input optical signal (combining wavelengths with the spacing at 100 GHz) into two parts: drop optical signal and straight-through optical signal, so as to implement the add/drop or straight-through of wavelengths with the spacing at 100 GHz Supports manual/automatic configuration of add or straight-through status for each wavelength in the EMS Supports the optical power equalization for each wavelength channel of output port Provides the optical power detection function for line input interface, drop interface, straight-through output interface, straight-through input interface, line output interface and each wavelength channel

200

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

All wavelengths will be blocked at the output port when the board is power down. After the board restarts, the status before power-down can recover automatically.

Operating Principle
Figure 98 illustrates the operating principle of WBM board.
FIGURE 98 OPERATING PRINCIPLE OF WBM BOARD
Line output Straight-through optical output Straight-through optical input ... Add 1 Add 2 ... Add 40 Control and Communication Unit ROAM Moduel Line input

Drop optical output

WBM board consists of an ROAM module and a control and communication unit. The following describes the function of each component of WBM board. ROAM Module Supports the configuration of wavelengths with the spacing at 100 GHz. Adds wavelengths from channel 1 to channel 40 or passes wavelengths through according to actual configuration requirements. The add or straight-through status of wavelengths can be set in the EMS manually or automatically. Divides the line input signal combining wavelengths with the spacing at 100 GHz into two parts: drop optical signal and straight-through optical signal Implements the optical power equalization function for channels of output interface with the following two modes: 1) Open loop control mode: In this mode, the ROAM module adjusts the attenuation amount of Variable Optical Amplifier (VOA) to achieve the power equalization. 2) Closed loop control mode: In this mode, the ROAM module controls the attenuation amount of VOA by setting the object optical power of each channel before MUX. The adjustment range of attenuation is 0 to 20 dB. The attenuation adjustment precision within the range from 0 to 10 dB is 0.7dB. The attenuation adjustment precision within the range from 10 dB to 20 dB is 1.3dB. When the power supply of the WBM board fails, the ROAM module will block all wavelengths at the output interfaces. After the power supply recovers, the status of all these wavelengths will recover too.

Control and Communication Unit

Confidential and Proprietary Information of ZTE CORPORATION

201

ZXMP M900 (V2.20) Hardware Manual

Detects and monitors the optical power of line input interface, drop interface, straight-through output interface, straight-through input interface, line output interface, as well as each wavelength channel, and then reports the information to the EMS Communicates with NCPF and APSF boards, executes the commands issued by the EMS, and forwards configuration and adjustment commands to the ROAM module

Front Panel: Interfaces and Indicators


Figure 99 shows the front panel of WBM board.
FIGURE 99 FRONT PANEL OF WBM BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

Table 100 describes the front panel and related information for basic operations of WBM board.

202

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 100 DESCRIPTION OF WBM BOARDS FRONT PANEL AND RELATED OPERATION INFORMATION

Board Item Board ID Indicator NOM ALM An DROP EXIN EXOUT IN OUT Laser warning sign Laser class sign Number of occupied slot Slots for WBM board

WBM WBM Running indicator, green Alarm indicator, red Optical add interface, n=1-40, LC/PC connector Optical drop interface, LC/PC connector Optical input interface of straight-through light, LC/PC connector Optical output interface of straight-through light, LC/PC connector Line optical input interface, LC/PC connector Line optical output interface, LC/PC Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of WBM board is CLASS 1 2

Optical interface

All slots in OTU subrack Slots in OA subrack except slot 6-9 Slots in TMUX subrack except slot 7 and slot 8 Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Operation precautions

Note: The relations between the working status and corresponding indicator status of WSB board are same as those of OTU board.

Optical Connections of WBM Board


Figure 100 illustrates the optical connections of WBM boards in an ROADM subsystem. As shown in Figure 100, an ROADM site needs two WBM boards, one connected to upstream site and the other connected to downstream site. Each WBM board supports the receiving and transmitting of optical signals in one optical direction.

Confidential and Proprietary Information of ZTE CORPORATION

203

ZXMP M900 (V2.20) Hardware Manual

FIGURE 100

OPTICAL CONNECTIONS OF WBM BOARD

The following explains the optical connections in the transmitting direction shown in Figure 100. The optical connections in the receiving direction are similar to those in the transmitting direction. Each WBM board only provides a pair of transmitting/receiving in one optical direction, that is , the interface IN/OUT connects to site A or site B. IN: accesses the amplified aggregate signals, and connects to the OUT interface on EOPA board. OUT: outputs aggregate signals, and connects to the IN interface on EOBA board.

DROP interface of WBM board is connected to IN interface of ODU board. The optical signals output from CHn interface of ODU board, complying with ITU-T G.692, can be output directly to the user equipments. The signals are also transmitted to the line interface of OTU boards, or to the aggregate interface of convergence board (SRM/GEM/DSA), and then transmitted to the user equipments via the corresponding client interface or tributary interface. An interface is connected to the line interface of OTU board, or aggregate interface of SRM/GEM/DSA board. And then the signals are transmitted to the user equipments via the corresponding client interface to tributary interface. EXIN/EXOUT of WBM board at side A is respectively connected to EXOUT/EXIN of WBM at side B.

204

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Performance and Alarm Messages


The performance, alarm and event messages of WBM board are listed in Table 101.
TABLE 101 PERFORMANCE, ALARM AND EVENT MESSAGES OF WBM BOARD

Type

Item Board environment temperature Input optical power

Performance

Output optical power AWG working temperature offset VOA attenuation amount Board environment temperature over-threshold alarm Board self-test failure alarm Module failure alarm Low output power alarm No output power alarm

Alarm

Output power over upper threshold alarm Output power below lower threshold alarm Low input power too low alarm No input power alarm Input power over upper threshold alarm Input power below lower threshold alarm Temperature over-threshold alarm MCU rest

Event

EEPROM data error Channel attenuation adjustment failure

SDM Board
Functions
SDM (Supervisory Division Multiplexing) board performs the multiplexing/demultiplexing of signals of the main optical channel and optical supervisory channel, cooperating with the EMS to implement supervision function.

Confidential and Proprietary Information of ZTE CORPORATION

205

ZXMP M900 (V2.20) Hardware Manual

It is applicable to such cases which needs no EOA board due to short span. The following two types of SDM board are available to replace EOBA board and EOPA board.

Operating Principle
The operating principle of SDM board is illustrated in Figure 101.
FIGURE 101 OPERATING PRINCIPLE OF SDM BOARD

1510/1550 Demultiplexer
Line input Line output Line input

1510/1550 Multiplexer
Line output

SDMR OSC

SDMT

Note: SDMR board has only 1510/1550 demultplexer while SDMT board has only 1510/1550 multiplexer.

SDMR: separates the optical supervisory channel signal (1510 nm) from the main optical channel signal (1550 nm) in the line signal (1510 nm + 1550 nm). SDMT: combines the optical supervisory channel signal (1510 nm) and the main optical channel signal (1550 nm) and then sends the combined signal (1510 nm + 1550 nm) to the line.

Front Panel: Interfaces and Indicators


The front panels of SDMT and SDMR board are shown in Figure 102.

206

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 102 FRONT P ANEL OF SDM BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign SDMT SDMR

TABLE 102 FRONT P ANEL DESCRIPTIONS OF SDM BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

Transmitting End SDM SDMT

Receiving End SDM SDMR

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes.

Laser warning sign

Laser class sign Optical interface IN OUT

Indicates that the laser class of SDM board is CLASS 1 1550 nm main optical channel input interface, LC/PC connector Line output interface interface, LC/PC Line input connector interface, LC/PC

1550 nm main optical channel output interface, LC/PC connector

Confidential and Proprietary Information of ZTE CORPORATION

207

ZXMP M900 (V2.20) Hardware Manual

Board Item SIN

Transmitting End SDM 1510 nm optical supervisory channel input interface, LC/PC connector Local monitoring output interface, LC/PC connector 1 All slots in OTU subrack

Receiving End SDM

1510 nm optical supervisory channel output interface, LC/PC connector Local monitoring output interface, LC/PC connector 1

SOUT

MON Number of occupied slot Slots for SDM board

Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The relations between the status of SDM board and corresponding status of indicators are same as those of the OTU board. Please refer to Table 31 for the detailed description.

Optical Connections of SDM Board


SDM board is configured in OTM equipment. The location of SDMT/SDMR board and the optical connection relations with other boards are illustrated in Figure 103.
FIGURE 103 OPTICAL CONNECTION OF SDM BOARD

OTU1 OTU2

1 2 n 1 2 n
O D U
OUT

O M U
IN OUT

SDMT

OTUn

OSC
OSCT

SIN

MON

OPM

OTU1 OTU2

OSC
SOUT

MON

SDMR

IN

OTUn

208

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Performance and Alarm Messages


The performance and alarm messages of SDM board are listed in Table 103.
T AB L E 1 0 3 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F SDM B O AR D

Type Performance

Item Input optical power Output optical power No input optical power alarm Low input optical power alarm No output optical power alarm Low output optical power alarm -

Remark Only for SDMR board Only for SDMT board Only for SDMR board Only for SDMT board -

Alarm

Event

Optical Amplification Boards


Board ID EOA DRA Full Name Enhanced Optical Amplifier Distributed Raman Amplifier Applicable Position OA/OTU subrack

EOA Board
Function and Operating Principle
EOA (Enhanced Optical Amplifier) board adopts Erbium-Doped Fiber Amplifier (EDFA) to amplify optical signals, which uses the full light amplification mode to replace the original electrical regeneration mode. In this way, both the cost and the complexity of the system are reduced. EOA board provides the feature of high transient response, which can meet the transmitting requirement of single-channel system at 10Gbit/s rate and the long distance DWDM system. The saturated output power of EOA board is up to 24 dBm. EOA board also provides the following functions. Gain major adjustment, gain lock and power clamp function Gain lock: EOA board adopts the fixed gain amplification mode. The gain lock value can be adjusted to meet the needs of different regeneration distance. Within the full input and full operating

Confidential and Proprietary Information of ZTE CORPORATION

209

ZXMP M900 (V2.20) Hardware Manual

temperature range, the error of signal gain lock precision is no more than 0.1 dB. Power clamp: When the input optical power is too high or too low, EOA board can control its output power with the power clamp function to avoid the optical surge of EDFA. The power clamp includes two modes: Upper clamp: Under this mode, the output power always keeps the nominal output value when the input power reaches the saturated output power. Lower clamp: It ensures that a certain small optical power will be output from the EOA board when the EOA board has no input light. Automatic Power Reduction (APR) function When the system detects that there is no input light on the link, it will shut down or reduce the output optical power of the EOA board automatically. When the input light recovers, EOA board will work again. In this way, the optical power level is always in the safe range while operators maintain or repair fibers of the optical line. APR: It acts on an OTS. When any OTS fails, all the other OTSs and downstream alarms will not be influenced. During the APR processing, the EOA board at each receiving end outputs clamped optical power, while the EOA board at each transmitting end is shut down.

Note: OTS: It is an optical path between OTM/OADM and OLA, or between OLAs

Supervision function EOA board has a 1510/1550 multiplexer and a 1510/1550 demultiplexer to add and drop the supervisory wavelength (1510 nm). However, EOA board does not process the supervisory signal (1510 nm).

EOA board also provides feature monitoring and alarm processing functions, which will be implemented according to the requirement of EMS.

EOA board can amplify optical signals in C/L band. In terms of its position and function in the network, OA board falls into three types: Enhanced Optical Booster Amplifier (EOBA), Enhanced Optical Line Amplifier (EOLA) and Enhanced Optical Pre-Amplifier (EOPA), as described in Table 104. According to different band and output power, the board can be classified into several subtypes, as listed in Table 105.
TABLE 104 TYPE LIST OF EOA BOARD

Type EOBA

Position Located after light emitter of OTM equipment regenerator equipment

Function It boosts the emitting power so as to extend the transmission distance.

210

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Type

Position Located in the middle of an OMS without dispersion compersation

Function It inserts EDFA in the optical transmission link to amplify optical signals directly. Multiple EOLAs can be used in an OMS as needed. It preamplifiers optical signals having been attenuated through the optical line so as to enhance the optical power to meet the sensitivity of optical receivers. It inserts EDFA in the optical transmission link to amplify optical signals directly. The gain range can be adjusted greatly to meet the requirements of different regeneration distances. DCM module can be inserted in the middle for the dispersion compensation.

EOLA

EOPA

Located at the end of an OMS and before light receiver

EONA

Located in the middle of an OMS

TABLE 105 LIST OF BOARD SUBTYPE

Board Type

Board Subtype EOBAS EOBAD

Band C CL

Output Optical Power (dBm) P20 P20

Remark Single-slot, connector Double-slot, connector Double-slot. OUT interface: interfaces: LC/PC LC/PC LC/PC LC/PC

EOBA EOBAH CL 20<P26

E2000/APC Other LC/PC Single-slot, connector Double-slot, connector Double-slot. OUT interface: interfaces: LC/PC LC/PC

EOLAS EOLAD EOLA EOLAH

C CL

P20 P20

CL

20<P26

E2000/APC Other LC/PC Single-slot, connector Double-slot, connector Double-slot, LC/PC

EOPAS EOPA EOPAD EONA EONAD

C CL CL

P20 P20 P20

Confidential and Proprietary Information of ZTE CORPORATION

211

ZXMP M900 (V2.20) Hardware Manual

Board Type

Board Subtype

Band

Output Optical Power (dBm)

Remark connector Double-slot. OUT interface: interfaces:

EONAH

CL

20<P26

E2000/APC Other LC/PC

Different type of EOA board also provides the following features: The saturation output power of EOBAH board is up to 26 dBm. The features of EONA board are listed as follows: Supports gain adjustment in a large range, which is up to 10 dB to meet the requirements of different line and regeneration distance. Supports the function of gain gradient adjustment. the adjustment range is 0.5 dB to 1 dB to compensate the power difference of each channel caused by the SRS effect in the long-distance DWDM system. Supports the output power adjustment in a large range. The range is -10 dBm to the saturation output power. Supports the function of inserted DCM attenuation.

EOBA/EOLA/EOPA board supports the gain adjustment to provide the adjustment range up to 2 dB.

Operating Principle
Operating principle of EOBA/EOLA/EOPA
The operating principle of EOBA/EOLA/EOPA board is similar. Take EOLA board for example, the operating principle is shown in Figure 104.

212

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 104 OPERATING PRINCIPLE OF EOL A BO ARD

1550nm Line Input 1510/1550 Demultiplexer Coupler

1550nm EDFA

1550nm Coupler

1550nm 1510/1550 Multiplexer

Line Output

1510nm Optical Power Monitoring EDFA Drive Circuit Optical Power Monitoring

1510nm Online Monitoring at Output Interface

Control and Communication

After entering the EOLA board, the optical line signal is separated by the 1510/1550 demultiplexer into the signal with the wavelength 1510 nm and that with the wavelength 1550 nm. The 1510 nm wavelength is sent to the OSC/OSCF board while the 1550 nm wavelength is sent to the EDFA module for amplification. After that, these two wavelengths are combined again by the 1510/1550 multiplexer and then are output from the EOLA board. The function of each module in the EOLA board is described as follows: 1510/1550 demultiplexer, 1510/1550 multiplexer Located at the receiving and transmitting end of the EOLA board respectively, the demultiplexer and the multiplexer implement the separation and combination of the supervisory channel (1510 nm) and the main optical channel (1550 nm). The EOBA board only has the multiplexer; the OPA board only has the demultiplexer; while the OLA board has both the demultiplexer and the multiplexer. Coupler One coupler is after the 1510/1550 demultiplexer and another coupler is before the 1510/1550 multiplexer. They extract some light from the main optical channel signal and send it to two optical power monitoring modules. Optical power monitoring module It receives the small amount of optical signal from the coupler, monitors the optical power and implements the gain control. The optical power monitoring module at the transmitting end also provides an online monitoring interface for the purpose of monitoring the parameters such as line spectrum and optical power with instruments without influencing the traffic. EDFA, EDFA drive circuit The EDFA amplifies the optical signal with the wavelength 1550 nm. The amplification is controlled by the EDFA drive circuit, which has the functions of gain adjustment, power clamp, gain lock, APSD and APR.

Confidential and Proprietary Information of ZTE CORPORATION

213

ZXMP M900 (V2.20) Hardware Manual

The gain adjustment range of the OA board suitable for 32-channel systems is 3 dB; while for the OA board suitable for 40-channel systems, the gain adjustment range is 2 dB. The adjustment precision is 0.1 dB. Control and communication unit It checks the input/output optical power and reports it to the EMS. At the same time, it receives control commands from the EMS.

Operating principle of EONA board


The operating principle of EONA board is illustrated in Figure 105.
FIGURE 105 OPERATING PRINCIPLE OF EON A BOARD

After entering the EONA board, the optical line signal is separated by the 1510/1550 demultiplexer into the signal with the wavelength 1510 nm and that with the wavelength 1550 nm. The 1510 nm wavelength is sent to the OSC/OSCF board. On the other hand, the 1550 nm wavelength is sent to the EDFA module for the first grade amplification, and then it is accessed into the DCM module for dispersion compensation after gain adjustment in EVOA module. Then, the 1550 nm wavelength is proceeded the second grade amplification in EDFA module. After that, these two wavelengths are combined again by the 1510/1550 multiplexer and then are output from the EONA board. The function of each module in the EONA board is described as follows: 1510/1550 demultiplexer, 1510/1550 multiplexer Located at the receiving and transmitting end of the OA board respectively, the demultiplexer and the multiplexer implement the separation and combination of the supervisory channel (1510 nm) and the main optical channel (1550 nm). Coupler

214

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

One coupler is after the 1510/1550 demultiplexer and another coupler is before the 1510/1550 multiplexer. They extract some light from the main optical channel signal and send it to two optical power monitoring modules. Optical power monitoring module It receives the small amount of optical signal from the coupler, monitors the optical power and implements the gain control. The optical power monitoring module at the transmitting end also provides an online monitoring interface for the purpose of monitoring the parameters such as line spectrum and optical power with instruments without influencing the traffic. EDFA, EDFA drive circuit The EDFA amplifies the optical signal with the wavelength 1550 nm. The amplification is controlled by the EDFA drive circuit, which has the functions of gain adjustment, power clamp, gain lock, APSD and APR. The gain adjustment range of EONA board is 10 dB ( 5 dB). The adjustment precision is 0.1 dB. EVOA (Electrically Variable Optical Attenuator) It adjusts optical attenuation according to the commands from EMS. Control and communication unit It checks the input/output optical power and reports it to the EMS. At the same time, it receives control commands from the EMS.

Front Panel: Interfaces and Indicators


EOA board can be divided into three types: EOBA, EOLA and EOPA. EOBA board Figure 106 illustrates the front panel of EOBA board.

Confidential and Proprietary Information of ZTE CORPORATION

215

ZXMP M900 (V2.20) Hardware Manual

FIGURE 106 FRONT P ANEL OF EOBA BOARD

EOBAS

EOBAD

EOBAH

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

TABLE 106 FRONT P ANEL DESCRIPTIONS OF EOBA BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID

EOBA EOBAS EOBAD EOBAH

Located below the board ID on the front panel. Label mn m: two digits, indicating the amplification gain of EOBA board. For example, 25 means the gain of OBA board is 25 dB. n: two digits, indicating the saturated output power of EOBA board. For example, 20 means the output optical power is 20 dBm.

Indicator
[Note]

NOM ALM

Running indicator, green Alarm indicator, red

216

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item Board ID IN MON Optical interface SIN

EOBA EOBAS EOBAD EOBAH

Line input interface, LC/PC connector Local monitoring output interface, LC/PC connector 1510 nm input interface, LC/PC connector Line output interface, LC/PC connector Line output interface, LC/PC connector Line output interface, E2000/APC connector

OUT

Laser warning sign

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of EOBA board CLASS 3R 1 CLASS 3B 2 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging fiber pigtail connectors while plugging/unplugging the board. Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. CLASS 3B 2

Laser class sign Number of occupied slot

Slots for OLA board

Operation precautions

Note: The relations between the working status and corresponding indicator status
of EOBA board are same as those of OTU board. Please refer to Table 31 for detailed description.

EOLA board Figure 107 illustrates the front panel of EOLA board. Table 107 describes the front panel and related basic operations of EOLA board.

Confidential and Proprietary Information of ZTE CORPORATION

217

ZXMP M900 (V2.20) Hardware Manual

FIGURE 107 FRONT P ANEL OF EOL AD BOARD

EOLAS

EOLAD

EOLAH

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

TABLE 107 FRONT P ANEL DESCRIPTIONS OF EOL A BO ARD AND REL ATED BASIC OPERATIONS

Board Item Board ID

EOLA EOLAS EOLAD EOLAH

Located below the board ID on the front panel. Label mn m: two digits, indicating the amplification gain of EOBA board. For example, 27 means the gain of OBA board is 27 dB. n: two digits, indicating the saturated output power of EOBA board. For example, 20 means the output optical power is 20 dBm.

Indicator
[Note]

NOM ALM IN

Running indicator, green Alarm indicator, red Line input interface, LC/PC connector

Optical

218

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item Board ID interface MON SIN SOUT

EOLA EOLAS EOLAD EOLAH

Local monitoring output interface, LC/PC connector 1510 nm input interface, LC/PC connector 1510 nm output interface, LC/PC connector Line output interface, LC/PC connector Line output interface, LC/PC connector Line output interface, E2000/APC connector

OUT

Laser warning sign

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of EOLA board CLASS 3R 1 CLASS 3B 2 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging fiber pigtail connectors while plugging/unplugging the board. Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. CLASS 3B 2

Laser class sign Number of occupied slot

Slots for OLA board

Operation precautions

Note: The relations between the working status and corresponding indicator status
of EOBA board are same as those of OTU board. Please refer to Table 31 for detailed description.

EOPA board Figure 108 illustrates the front panel of EOLA board. Table 108 describes the front panel and related basic operations of EOLA board.

Confidential and Proprietary Information of ZTE CORPORATION

219

ZXMP M900 (V2.20) Hardware Manual

FIGURE 108 FRONT P ANEL OF EOP AD BOARD

EOPAS

EOPAD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

TABLE 108 FRONT P ANEL DESCRIPTIONS OF EOP A BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID

EOPA EOPAS EOPAD

Located below the board ID on the front panel. Label mn m: two digits, indicating the amplification gain of EOBA board. For example, 22 means the gain of OBA board is 22 dB. n: two digits, indicating the saturated output power of EOBA board. For example, 12 means the output optical power is 12 dBm.

Indicator
[Note]

NOM ALM

Running indicator, green Alarm indicator, red

220

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item Board ID IN Optical interface MON SOUT OUT Laser warning sign

EOPA EOPAS EOPAD

Line input interface, LC/PC connector Local monitoring output interface, LC/PC connector 1510 nm output interface, LC/PC connector Line output interface, LC/PC connector Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of EOPA board CLASS 3R 1 CLASS 3B 2 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging fiber pigtail connectors while plugging/unplugging the board. Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Laser class sign Number of occupied slot

Slots for OLA board

Operation precautions

Note: The relations between the working status and corresponding indicator status
of EOBA board are same as those of OTU board. Please refer to Table 31 for detailed description.

EONA board Figure 108 illustrates the front panel of EONA board. Table 108 describes the front panel and related basic operations of EONA board.

Confidential and Proprietary Information of ZTE CORPORATION

221

ZXMP M900 (V2.20) Hardware Manual

FIGURE 109 FRONT P ANEL OF EONA BOARD

EONAD

EONAH

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

TABLE 109 FRONT P ANEL DESCRIPTIONS OF EONA BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID

EONA EONAD EONAH

Located below the board ID on the front panel. Label mn m: two digits, indicating the amplification gain of EOBA board. For example, 25 means the gain of OBA board is 25 dB. n: two digits, indicating the saturated output power of EOBA board. For example, 20 means the output optical power is 20 dBm.

Indicator
[Note]

NOM ALM

Running indicator, green Alarm indicator, red

222

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item Board ID IN DCM1 DCM2 Optical interface SIN MON1 MON2 SOUT OUT

EONA EONAD EONAH

Line input interface, LC/PC connector DCM input interface, LC/PC connector DCM output interface, LC/PC connector 1510 nm input interface, LC/PC connector Local monitoring output interface, LC/PC connector

1510 nm output interface, LC/PC connector Line output interface, LC/PC connector Line output interface, E2000/APC connector

Laser warning sign

Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of EONA board is CLASS 3B 2 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging fiber pigtail connectors while plugging/unplugging the board. Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Laser class sign Number of occupied slot

Slots for OLA board

Operation precautions

Optical Connections of EOA Board


Figure 110 illustrates typical optical connections of EOA boards.

Confidential and Proprietary Information of ZTE CORPORATION

223

ZXMP M900 (V2.20) Hardware Manual

FIGURE 110
OTM
EAST Input

TYPICAL OPTICAL CONNECTIONS OF EO A BOARD


OLA EOBA EOLA EOPA

OTM
EAST Output

OSC
OPM OSC

OSC
OPM

OSC
OSC

OSC
OSC OPM

OSC

OSC

WEST Output

EOPA

EOLA

EOBA

WEST Input

EOBA board: receives multiplexed optical signal through IN interface, and outputs the amplified signal through OUT interface. The monitoring signal from OSC board is input to OBA board through SIN interface. The MON interface is connected to OPM board. EOPA board: receives optical line signal through IN interface and outputs the amplified signal through OUT interface. It outputs the monitoring signal to OSC board through SOUT interface. The MON interface is connected to OPM board. EOLA board: receives optical line signal to be amplified through IN interface, and outputs amplified line signal through OUT interface. Its SIN/SOUT interfaces are connected to the output/input interfaces of OSC board. The MON interface is connected to OPM board.

Performance and Alarm Messages


The performance messages of EOA board are listed in Table 110.
TABLE 110 PERFORM ANCE MESSAGES OF EO A BO ARD

Type

Item Pump laser n bias current Pump TEC current

Remark n=1-4 n=1-4, only EOA board with TEC function has this performance n=1-4, only EOA board with TEC function has this performance n=1-4Only EOA board of L board has this performance. Only for EONA board

Board

Pump laser temperature offset Pump background PD current Board Environment temperature EDF temperature

Inner-modulation interface EOA Interface Input

Amount of Optical attenuation Input optical power

224

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Type

Item Output optical power Pump reflection power

Remark Only EOA with the output power is higher than 24 dBm has this performance Only EOA with the output power is higher than 24 dBm has this performance

EOA Output Interface

Pump reflectance

Note: for the pump laser n (n>1), the perfomance value is only exist if the number
of pump is more than one.

The alarm messages of EOA board are listed in Table 111.


T AB L E 1 1 1 AL AR M M E S S AG E S O F E O A B O AR D

Type

Item Pump laser n bias current over-threshold alarm Pump laser n cooling current over-threshold alarm Pump laser over-threshold temperature offset

Remark n=1-4 n=1-4, only EOA board with TEC function has this performance n=1-4 n=1-4temperature Only EOA board with TEC function in L board has this performance. -

Board

Pump laser n end-of-life alarm Board Environment over-threshold alarm

EDF temperature offset out of limit alarm Modules failure or communication fault alarm DSP operating alarm High input optical power alarm EOA Input Interface Low input optical power alarm Input optical power out of upper limit alarm Input optical power out of lower limit alarm EOA Output Interface High output optical power alarm Low output optical power alarm No output optical power alarm Output optical power out of upper limit alarm Output optical power out of lower limit alarm

Confidential and Proprietary Information of ZTE CORPORATION

225

ZXMP M900 (V2.20) Hardware Manual

Type

Item High reflection power alarm

Remark Only for EOA board with the output power higher than 24 dBm Only for EOA board with the output power higher than 24 dBm

High reflectance alarm

The event messages of EOA board are listed in Table 112.


TABLE 112 EVENT MESSAGES OF EOA BOARD

Type

Item MCU reset

Remark It is only reported when the board software operates automatically rather than when EMS sends commands It is only reported when the board software operates automatically rather than when EMS sends commands -

Board Port

DSP start-up DSP download program failure Board data configuration is faulty

EDFA pump laser automatic shut-down

Output Port

EDFA pump laser automatic startup

Enter optical power control Quit optical power control Internal Module Interface Attenuation adjustment failure

DRA Board
Functions
RAMAN amplifiers share the characteristics of small noise coefficient, adjustable gain, flat gain, standard structure and high reliability. The DRA board implements the distributed amplification of optical signals by using RAMAN amplifier to feed the RAMAN pump light into transmission fiber in the reverse direction. Cooperating with EDFA, it is applicable to single-hop ultra-long distance systems. The DRA board has the following functions.

226

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Supporting the amplification of wavelengths in C band, L band and C+L band (1529 nm-1604 nm), and implementing ultra-capacity and ultra-long distance optical fiber communication Supporting gain adjustment, gain spectrum adjustment and gain stabilization Gain adjustment: Adjust pump laser optical power, combining with gain adjustment of EDFA. During the adjustment, it adopts slow change control so as to improve system security. Gain spectrum adjustment: Adjust optical power of each pump laser respectively to implement the spectrum adjustment so as to solve problems of channel flatness. Gain stabilization: Stabilize pump power.

Laser automatic shut-down Performance monitoring and alarm processing, performing corresponding operations according to requirements of EMS

Operating Principle
The operating principles of DRA board are different for the amplification of C-band wavelengths and L-band wavelengths. Figure 111 and Figure 112 illustrates the operating principles of DRA board in case of C band and C+L band wavelength amplification respectively.
FIGURE 111 OPERATING PRINCIPLE OF DRA BOARD (C BAND)

C-band optical signal input Extended pump light

C-band optical signal output

RAMAN Pump Module (C-Band)

Output online monitoring

Control and Communication Unit

Confidential and Proprietary Information of ZTE CORPORATION

227

ZXMP M900 (V2.20) Hardware Manual

FIGURE 112 OPERATING PRINCIPLE OF DRA BOARD (C+ L BAND)

DRA (C band)
C+L band optical signal input C+L band optical signal output

Extended pump light

RAMAN Pump Module (C-Band)

C band output online monitoring

Control and Communication Unit

RAMAN Pump Module (L-Band)

L band output online monitoring

Control and Communication Unit DRA (L band)

Two types of RAMAN pump modules are available for DRA board, C-band module and L-band module. C-band RAMAN module works independently in system, while L-Band module can only work with the cooperation of C-band module. C-band RAMAN module: Works independently to amplify C-band optical signals. It has the functions of output power detection, pump light multiplexing and pump/signal coupling. L-band RAMAN module: Only provides driver for pump source and amplifies L-band optical signals. It must be used with C-band together. While L-band RAMAN module and C-band RAMAN module work together, the DRA board receives optical signals through the input interface of C-band module. C-band signals are amplified in C-band module. L-band signals are amplified in L-band and then the amplified signals are input to C-band module through the extended pump optical interface. Finally, the C-band module outputs amplified C+L band optical signals together.

228

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Front Panel: Interfaces and Indicators


The front panel of DRA board is illustrated in Figure 113.Table 113 describes the front panel and related operations of DRA board.
FIGURE 113 FRONT P ANEL OF DRA BO ARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign
DRAC-band DRAL-band

TABLE 113 FRONT P ANEL DESCRIPTIONS OF DRA BO ARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

DRAC-band DRA

DRAL-band DRA

NOM ALM warning

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes.

Laser sign

Confidential and Proprietary Information of ZTE CORPORATION

229

ZXMP M900 (V2.20) Hardware Manual

Board Item IN

DRAC-band C-band or C+L band optical signal input interface, E2000/APC connector C-band or C+L band optical signal output interface, LC/PC connector Local monitoring output interface, LC/PC connector Extended interface for L-band pump light, LC/PC connector C-band pump monitoring output interface, LC/PC connector 2

DRAL-band

OUT Optical interface MON EXT PMON POUT Number occupied slot Laser class sign Slots board for DRA of

L-band pump monitoring output interface, LC/PC connector L-band pump light output interface, LC/PC connector 2

Indicates that the laser class sign of DRA is CLASS 3B All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. A board slot at the right side of DRA should be reserved without inserted board at the right of DRA board for heat dissipation. In the application of DRA board, connectors used in optical line should be as few as possible. The reflectance of fiber connecting surface should be no more than -30 dB so as to ensure the amplification efficiency of DRA board. If line optical fiber route changes or optical fiber changes, fiber pigtails connected to DRA board should be recleaned. Record reflectance and reflected power of DRA board.

Operation precautions

Cleaning precautions

Use fiber microscope to observe optical fibers to check whether they are clean while cleaning fiber surfaces for DRA board. The reflectance should be no more than -30 dB (the reflectance alarm threshold is -15 dB). Clean fiber surface once you plug/unplug fiber pigtails or replace DRA board.

Note: The relationship between the status of DRA board and corresponding status of indicators are same as that of the OTU board. Please refer to Table 31 for the detailed description.

230

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Optical Connections of DRA Board


C-band DRA board can be used separately to implement the amplification of C-band optical signals. L-band DRA band must be used with C-band DRA board together. Connect the POUT interface of L-band DRA board to the EXT interface of C-band DRA board to implement the amplification of C and L band optical signals. In ultra-long distance systems, DRA board is used with small gain OA boards in series. The location and optical connection relation of DRA board is shown in Figure 69.

Performance and Alarm Messages


The performance and alarm messages of DRA board are listed in Table 114.
T AB L E 1 1 4 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F D R A B O AR D

Type

Item Laser TEC current Laser temperature offset Output optical power Output optical power of pump Reflected optical power of pump Pump reflectance Inner-module temperature Module temperature alarm Pump reflection power high alarm Pump refection rate high alarm No output optical power alarm

Remark Only C-band DRA board has this performance. Only C-band DRA board has this performance. Only C-band DRA board has this performance. -

Alarm Low output optical power alarm Pump laser bias current over-threshold alarm Pump laser TEC current over-threshold alarm Pump temperature offset alarm Event Pump laser automatic shut-down Pump laser automatic start up

Confidential and Proprietary Information of ZTE CORPORATION

231

ZXMP M900 (V2.20) Hardware Manual

Power Management Boards


Board ID LAC OWM OPM MCPD Full Name Line Attenuation Compensator Optical Wavelength Monitor Optical Performance Monitor Multiple Channel Power Detector OA/OTU subrack Applicable Position

LAC Board
Functions
The LAC board adjusts its electrically variable optical attenuator (EVOA) through the EMS according to measured line optical power to ensure the power of each span, received power at receiving end and OSNR keep normal. The operating wavelength range of LAC board is C band or L band. The intrinsic insertion loss is less than 2 dB. The adjustment range of EVOA is 2 dB-26 dB, the adjustment precision is 0.5 dB and adjustment step is 0.2 dB. LAC board includes two types: LACG and LACT. LACG board: It has two EVOAs, being applicable to OLA, OADM and back-to-back OTM sites. LACT board: It has one EVOA, being applicable to single-end OTM sites.

The LAC board supports the monitoring function for input power and output power. LAC board with Gain Flattening Filter (GFF) can compensate DWDM spectral dipping caused by Simulated RAMAN Scattering effect to improve transmitting performance of the system.

Operating Principle
Taking an LACG board as example, Figure 114 illustrates its operating principle.

232

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 114 OPERATING PRINCIPLE OF LAC BOARD (L ACG)

IN1

Coupler

GFF

EVOA

Coupler

OUT1

Optical Power Monitoring Unit

Optical Power Monitoring Unit

EVOA Drive Circuit

Optical Power Monitoring Unit

Control and Communiction Unit

Optical Power Monitoring Unit

OUT2

Coupler

EVOA

GFF

Coupler

IN2

Note: Compared with LACG board, LACT board reduces an optical direction. The EMS sends attenuation adjustment command through the control and communication unit in LAC board. Upon receiving the command, the EVOA drive circuit drives corresponding EVOA in the optical receiving module to adjust attenuation amount. EVOA: electrically variable optical attenuator; an EVOA is configured for each optical direction, which is driven by EVOA drive circuit. Coupler: separates optical signal from the main optical channel and sends part of the signal to the optical power measuring unit. EVOA drive circuit: reports measured input optical power and output optical power to control and communication unit. Meanwhile, it receives control commands from the control and communication unit and sends adjustment command to EVOA. Optical power measuring unit: measures output optical power and input optical power, and feeds it to EVOA drive circuit. GFF: uses to compensate the DWDM spectral dipping caused by SRS effect. GFF is an optional element. Control and communication unit It reports the power value received from the optical power monitoring module to the EMS, and receives control commands from the EMS.

Front Panel: Interfaces and Indicators


The front panels of LACG board and LACT board are illustrated in Figure 115. Table 115 describes the front panel and related basic operations of LAC board.

Confidential and Proprietary Information of ZTE CORPORATION

233

ZXMP M900 (V2.20) Hardware Manual

FIGURE 115 FRONT P ANEL OF L AC BOARD

LACG Board

LACT Board

TABLE 115 FRONT P ANEL DESCRIPTIONS OF L AC BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

LACG LACG

LACT LACT

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Optical input interface 1, LC/PC connector Optical input interface, LC/PC connector Optical output interface, LC/PC connector -

Laser warning sign Optical interface

IN OUT IN1

234

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item OUT1 IN2 OUT2 Number of occupied slot Laser class sign Slots for LAC board

LACG Optical output interface LC/PC connector 1,

LACT 1

Optical input interface 2, LC/PC connector Optical output interface LC/PC connector 1 2,

Indicates that the laser class of LAC board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The relations between the status of LACG/LACT board and corresponding status of indicators are same as those of the OTU board. Please refer to Table 31 for the detailed description.

Optical Connections of LAC Board


The LACG board is applicable to OLA, OADM and back-to-back OTM sites while the LACT board is applicable to single-end OTM sites. The optical connections of LAC boards can be divided into two types, as described in Figure 116 and Figure 117 respectively. For the first connection way shown in Figure 116, LACT boards are usually configured after EOBA board, while LACG boards are configured before EOLA board. LACT boards are configured before EOPA boards, while LACG boards are configured before EOLA boards as shown in Figure 117.
FIGURE 116 THE OPTICAL CONNECTION OF L AC BOARDS (1)
OTM OLA OTM

EOBA

LACT

EOLA LACG

EOPA

EOPA

EOLA

LACT

EOBA

Confidential and Proprietary Information of ZTE CORPORATION

235

ZXMP M900 (V2.20) Hardware Manual

FIGURE 117 THE OPTICAL CONNECTION OF L AC BOARDS (2)


OTM OLA OTM

EOBA LACG EOPA LACT EOLA

EOLA

LACT

EOPA

EOBA

Performance and Alarm Messages


The performance and alarm messages of LAC board are listed in Table 116.
T AB L E 1 1 6 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F LAC B O AR D

Type Performance

Item Output optical power Input optical power High input optical alarm No output optical alarm

Alarm

Low output optical alarm No input optical alarm Low input optical alarm Attenuation adjustment failure

Event

MCU reset Data configuration of board is faulty

OWM Board Functions


OWM (Optical Wavelength Monitor) board functions to supervise central frequency drift of optical channels after these channels have been multiplexed and then send the frequency adjustment message to NCPF board. Each OWM board can implement the wavelength control for bidirectional 80 C-band wavelengths. The impact of frequency drift is relatively small in a DWDM system with the channel spacing at 100 GHz. However, in a system with higher single channel rate and smaller channel spacing (for example, in the system with the spacing at 50 GHz), the frequency drift will influence the system stability directly.

236

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

In an 80-channel DWDM system with the spacing at 50 GHz consisting of ZXWM M900, OWM board, multiplexing type boards, OTU series boards, EOA board, master board (NCPF/NCPF) and the EMS ZXONM E300 can be combined to build up a centralized wavelength supervision subsystem to improve the stability and precision of wavelength control.

Note: For detailed knowledge of integrated wavelengh supervision subsystem, please refer to Appendix C in this manual.

OWM board functions to supervise central frequency drift of optical channels after multiplexing and send frequency adjustment message to NCP/NCPF board. Each OWM board can implement the wavelength control for bidirectional 80 C-band or L-band wavelengths.

Operating Principle
The operating principle of OWM board is illustrated in Figure 118.
FIGURE 118 OPERATING PRINCIPLE OF OWM BOARD
C/L-band input light 1

Control and Communication Unit

C/L-band input light 2

12 Optical Switch

TF

Detection wavelengh

Wavelength Supervisor

Reference wavelength Detection wavelength

Wavelength control message

NCP or NCPF

TF Drive Circuit Optical Switch Drive Circuit

OWM board consists of a 12 optical switch, tunable filter (TF), wavelength supervisor, drive circuits and the control and communication unit. 12 optical switch: selects aggregate optical signals to be detected. Each OWM board can only detect either C-band 80-channel aggregate signal or L-band 80-channel aggregate signal. TF: uses narrow-band tunable filter to get current detection wavelength, which is set in the EMS ZXONM E300. Wavelength supervisor: monitors wavelength offset according to the detection wavelength got from the TF. It also acts as synchronization check device during wavelength adjustment. Drive circuits: includes optical switch drive circuit and TF drive circuit. They receive control commands from the control and communication unit and then drive the 12 optical switch and TF.

Confidential and Proprietary Information of ZTE CORPORATION

237

ZXMP M900 (V2.20) Hardware Manual

Control and communication unit: drives optical switch and TF via optical switch drive circuit and TF drive circuit. It calculates wavelength offset according to the detection wavelength and reference wavelength got from the wavelength supervisor. It also sends adjustment command to NCP/NCPF board.

Front Panel: Interfaces and Indicator


The front panel of OWM board is illustrated in Figure 119. Table 117 describes the front panel and related basic operations of OWM board.
FIGURE 119 FRONT P ANEL OF OWM BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

TABLE 117 FRONT P ANEL DESCRIPTIONS OF OWM BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

OWM OWM

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes.

Laser warning sign

238

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item Optical interface IN1 IN2

OWM Optical input interface 1 for C/L-band multiplexed signal, LC/PC connector Optical input interface 2 for C/L-band multiplexed signal, LC/PC connector 1 Indicates that the laser class of OWM board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Number of occupied slot Laser class sign Slots for OWM board

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The relations between the status of OWM board and corresponding status of indicators are same as those of the OTU board. Please refer to Table 31 for the detailed description.

Optical Connections of OWM Board


OWM board is configured at the transmitting end of the system. Each OWM board only detects two C/L-band 80-channel optical signals. Therefore, a 160-channel bidirectional node needs two OWM boards. An 80-channel four-direction node also needs two OWM boards. All optical transponder boards supervised by an OWM board must be managed by the same NCP/NCPF board with the OWM board. That is, the OWM board and optical transponder boards must be installed in the cabinet managed by the same NCP/NCPF board. For the detailed configuration of OWM board, please refer to Appendix C in this manual.

Confidential and Proprietary Information of ZTE CORPORATION

239

ZXMP M900 (V2.20) Hardware Manual

Performance and Alarm Messages


The performance and alarm messages are listed in Table 118.
T AB L E 1 1 8 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OW M B O AR D

Type Performance

Item Board environment temperature Wavelength offset over-threshold alarm

Remark Alarm threshold: wavelength offset is out of 5 GHz Alarm threshold: temperature is out of 0-65 -

Alarm

Board environment over-threshold alarm Module failure alarm

temperature

Supervision circuit damage or device fault Optical switch failure Successful wavelength adjustment Unable to supervise wavelength Wavelength band error Event Unadjustable object board Adjustment failed several times Wavelength adjustment time out Data error Data type do not match for the board type Agent can not find the corresponding wavelength or board

OPM Board
Functions
The OPM board implements the supervision of optical channel performance, measuring parameters of each optical channel, such as optical power, central wavelength and OSNR, and then reports these data to the EMS. Each OPM board detects performances of four optical interfaces. The precision for parameter measurement is as follows. Optical power: 1.0 dBm Central wavelength: 0.1 nm OSNR: 1.5 dB (OSNR<25 dB)

240

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Operating Principle
The operating principle of OPM board is illustrated in Figure 120.
FIGURE 120 OPERATING PRINCIPLE OF OPM BOARD

Optical switch

Detecting and Processing Unit

Control and Communication Unit

As shown in Figure 120, the OPM board has four optical interfaces. The detecting and processing unit measures parameters of each optical channel. Then the control and communication unit reports the detected performance data to the EMS, which can issue commands to query optical channel parameters through the control and communication unit.

Front Panel: Interfaces and Indicators


The front panel of OPM board is illustrated in Figure 121. The front panel and related basic operations are described in Table 119.

Confidential and Proprietary Information of ZTE CORPORATION

241

ZXMP M900 (V2.20) Hardware Manual

FIGURE 121 FRONT P ANEL OF OPM BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

TABLE 119 FRONT P ANEL DESCRIPTIONS OF OPM BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

OPM OPM

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Optical input interface 1, LC/PC connector Optical input interface 2, LC/PC connector Optical input interface 3, LC/PC connector Optical input interface 4, LC/PC connector 2 Indicates that the laser class of OPM board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8

Laser warning sign IN1 Optical interface IN2 IN3 IN4 Number of occupied slot Laser class sign Slots for OPM board

242

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item

OPM Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. Connect IN1, IN2, IN3 or IN4 interface to MON interface of a board to measure the parameters of optical channel occupied by this interface. The measured result is displayed in the ZXONM E300 EMS.

Note: The relationship between the status of OPM board and corresponding status of indicators are same as that of the OTU board. Please refer to Table 31 for the detailed description.

Performance and Alarm Messages


The performance and alarm messages of OPM board are listed in Table 120.
T AB L E 1 2 0 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OP M B O AR D

Type

Item Optical power of channel (optical interface 1-4) Central wavelength of channel (optical interface 1-4) OSNR of channel (optical interface 1-4) No channel optical power alarm (optical interface 1-4)

Remark Alarm threshold: 5 dB less than normal optical power Alarm threshold: the offset from nominal wavelength is out of the range 0.15 nm Alarm threshold: 3 dB less than the recommended OSNR index -

Performance

Alarm

Wavelength offset alarm (optical interface 1-4) OSNR alarm (optical interface 1-4) Optical switch failure (optical interface 1-4)

Event

Confidential and Proprietary Information of ZTE CORPORATION

243

ZXMP M900 (V2.20) Hardware Manual

MCPD Board
Board Function
MCPD board is applied in the ultra-long span system with DRA or RPU board, to correctly and quickly verify different statuses, such as no optical input, ASE noise input, and +ASE noise of multi-channel signal input. The position of MCPD board in the system is described in Figure 122.

Note: For detail description about RPU board, please refer to Unitrans ZXWM M900 (V2.20) Dense Wavelength Division Multiplexing Optical Transmission System RPOA Subsystem Users Manual.

FIGURE 122 THE POSITION OF MCPD BOARD IN THE SYSTEM

MCPD board provides the functions described as follows: Supports optical power monitoring for the aggregate input optical, and reports the data to the EMS system. Correctly monitors if the modulation signals exist in the input optical. Assists with APR and APSD functions. Supports the application in C+L band.

244

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Operating Principle
The operating principle of MCPD board is shown in Figure 123.
FIGURE 123 OPERATING PRINCIPLE OF MCPD BOARD

Signal Spectrum Monitoring O/E Conversion Power Monitoring

Control and Communication

After O/E conversion, the aggregate optical signals are accessed to the spectrum monitoring and power monitoring. And then the control and communication unit reports the monitoring result to the EMS. EMS system can send the query commands for the channel parameter via control and communication unit. O/E conversion It converts the aggregate optical signals into the electric signals, and then sends the signals to the spectrum monitoring unit and power monitoring unit. Spectrum monitoring It monitors the spectrum features and controls the gain for the electrical signals after O/E conversion. Power monitoring It monitors the power of input power. Control and communication unit It reports the signal spectrum and optical power to EMS, and accepts the control commands from EMS.

Performance and Alarm


THE PERFORMANCE AND ALARM MESSAGES OF MCPD BOARD ARE LISTED IN TABLE 121.

Confidential and Proprietary Information of ZTE CORPORATION

245

ZXMP M900 (V2.20) Hardware Manual

T AB L E 1 2 1 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F M C P D B O AR D

Type Performance

Item Input optical power Board self-test failure alarm Low optical power alarm No optical power alarm LOS alarm MCU reset Data error -

Remark

Alarm

Event Board criterion imcomplement

Board criterion includes optical power criterion and ASE monitoring voltage criterion.

Front Panel: Interfaces and Indicators


The front panel of MCPD board is illustrated in Figure 124. The front panel and related basic operations are described in Table 119.
FIGURE 124 FRONT P ANEL OF MCPD BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

246

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 122 FRONT P ANEL DESCRIPTIONS OF MCPD BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

MCPD MCPD

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Optical input interface, LC/PC connector 1 Indicates that the laser class of OPM board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Laser warning sign Optical interface

IN

Number of occupied slot Laser class sign Slots for OPM board

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. Connect IN interface to MON interface of a board to measure the parameters of optical channel occupied by this interface. The measured result is displayed in the ZXONM E300 EMS.

Protection Boards
Board ID OP OPCS OPMS OMCP Full Name Optical Protect Board Optical Protect for Channel Section Optical Protect for Mux Section Optical Multi-Channel Protection OA/OTU subrack Applicable Position

OP Board
Functions
The OP board is used to implement OMS line 1+1 protection and OCH 1+1 protection function.

Confidential and Proprietary Information of ZTE CORPORATION

247

ZXMP M900 (V2.20) Hardware Manual

It performs protection switching or restoring based on received optical power, manual switching/restoring command from EMS or automatic protection switching (APS) external command (complying with ITU-T G.841). With the ZXONM E300 EMS, users can manage current protection switching status of OP board.

Operating Principle
The operating principles of OP board are illustrated in Figure 125.
FIGURE 125 OPERATING PRINCIPLE OF OP BOARD

TOUT1 TIN Coupler TOUT2 Coupler

RIN1

1 2 switch

ROUT

RIN2

Coupler

Control and Communication Unit

As shown in Figure 125, there are two directions: concurrent transmitting direction from TIN to TOUT1/TOUT2, preferred receiving direction from RIN1/RIN2 to ROUT. In concurrent transmitting direction: Optical signal received through TIN are divided into two optical signals with same wavelength by the coupler, and then output through TOUT1 and TOUT2. These two optical signals protect each other. In preferred receiving direction: Optical signals received through RIN1 and RIN2 are input to corresponding couplers separately. Part of light output from couplers is input to the control and communication unit for optical power measurement. The other part of light is input to the 12 switch, which selects optical signal according to APS controllers instruction and measured optical power. Finally, the selected optical signal is output through ROUT port.

248

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Front Panel: Interfaces and Indicators


The front panel of OP board is illustrated in Figure 126.
FIGURE 126 FRONT P ANEL OF OP BOARD

1. Running and alarm indicators 2. Optical switching status indicator 3. Optical interface 4. Laser warning sign 5. Laser class sign

Table 123 describes the front panel and related basic operations of OP board.
TABLE 123 FRONT P ANEL DESCRIPTIONS OF OP BOARD AND REL ATED BASIC OPER ATIONS

Board Item Board ID Indicator


[Note]

OP OP

NOM ALM TIN

Running indicator, green Alarm indicator, red Transmitting end input interface, LC/PC connector Transmitting end working line/channel output interface, LC/PC connector Transmitting end protection line/channel output interface, LC/PC connector

Optical interface

TOUT1 TOUT2

Confidential and Proprietary Information of ZTE CORPORATION

249

ZXMP M900 (V2.20) Hardware Manual

Board Item Optical interface ROUT RIN1 RIN2 Number of occupied slot Laser sign warning

OP Receiving end output interface, LC/PC connector Receiving end working line/channel output interface, LC/PC connector Receiving end protection line/channel output interface, LC/PC connector 1 Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OP board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Laser class sign Slots for OP board

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Table 124 lists the relationship between the board status and corresponding status of indicators.
TABLE 124 CORRESPONDENCE RELATIONS INDICATOR STATUS OF OP BOARD WORKING STATUS

BETWEEN

THE

AND

Working Status The board is waiting for configuration. The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. Board initialing The board is waiting for download Downloading status Switching alarm No switching

Indicators NOM (Green) ALM (Red) STA Off

The red indicator and the green indicator flash alternately. Flashing regularly Flashing regularly On slowly and Off

slowly

and

On Flashing slowly and regularly

Off Off Off On (red) On (green)

The red indicator and the green indicator flash quickly at the same time. The red indicator and the green indicator flash slowly at the same time. Flashing regularly Flashing regularly slowly slowly and and -

250

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Note: STA bi-color indicators are green and red. The - symbol means that the indicator status is indefinite.

Optical Connections of OP Board


OP board can be used to implement OCH 1+1 protection and OMS 1+1 protection. The following introduces these two kinds of protection modes respectively. OCH 1+1 Protection OP board applies the operating principle of concurrent transmitting and preferential receiving to implement OCH 1+1 protection. Two configuration modes are available for OCH 1+1 protection function: OTU redundancy configuration and OTU shared configuration. OTU redundancy configuration mode In this mode, a pair of transmitter and receiver OTU type boards is configured on the working channel and the protection channel respectively. For OCH protection, OP boards are located before transmitting-end OTU board in optical terminal and after receiving-end OTU board. The OTU redundancy configuration mode is applicable to both chain networks and ring networks. Figure 127 illustrates the optical connection relation of OTU redundancy OCH 1+1 protection in a chain network.
FIGURE 127 OPTICAL CONNECTIONS OF OP BOARD (OTU 1+1 PROTECTION, OTU REDUNDANCY MODE IN CHAIN NETWORK)

Figure 128 illustrates the optical connection relation in a ring network.

Confidential and Proprietary Information of ZTE CORPORATION

251

ZXMP M900 (V2.20) Hardware Manual

FIGURE 128 OPTICAL CONNECTIONS OF OP BOARD (OTU 1+1 PROTECTION, OTU REDUNDANCY MODE IN RING NETWORK)

O M U Working channel OTU O P OTU OTU OTU O D U

O D U O M U

OTU OTU OTU OTU O P

O M U Protection channel O D U

O D U O M U

Transmitting end: The TIN interface of OP board is connected to transmitting optical interface of user equipment. The TOUT1 and TOUT2 interfaces are connected to client-side receiving optical interfaces of OTU board on the working channel and the protection channel respectively. Receiving end: The ROUT interface of OP board is connected to receiving optical interface of user equipment. The RIN1 and RIN2 interfaces are connected to client-side transmitting optical interfaces of OTU board on the working channel and the protection channel respectively. OTU shared configuration mode In this mode, a pair of transmitter OTU and receiver OTU are shared in the working channel and the protection channel. OP boards are located after transmitting-end OTU board in optical terminal and before receiving-end OTU board. The OTU shared configuration mode is only applicable to ring networks. Figure 129 illustrates the optical connection relation of OP board in the OTU shared configuration mode.

252

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 129 OPTICAL CONNECTION OF OP BOARD (OTU 1+1 PROTECTION)

O M U Working channel OTU O P OTU O M U Protection channel O D U O D U

O D U O M U

OTU O P OTU

O D U O M U

Transmitting end: TIN interface of OP board is connected to transmitting optical interface at line side of OTU board. TOUT1 and TOUT2 interfaces are connected to CHn optical interfaces of OMU boards on the working channel and the protection channel respectively. Receiving end: ROUT interface of OP board is connected to receiving optical interface at line side of OTU board. RIN1 and RIN2 interfaces are connected to CHn optical interfaces of ODU boards on the working channel and the protection channel respectively.

OMS 1+1 Protection For OMS protection, OP boards are located after multiplexed signal at the transmitting end of OTM equipment and before multiplexed signal at the receiving end of OTM equipment. According to the different positions of EOA boards, two configuration modes are available for OMS 1+1 protection function: EOA shared configuration mode and EOA redundancy configuration mode. EOA shared configuration mode In this mode, a pair of EOBA/EOPA board is shared on the working channel and the protection channel. OP boards are located after transmitting-end EOBA board in optical terminal and before receiving-end EOPA board, as shown in Figure 130.

Confidential and Proprietary Information of ZTE CORPORATION

253

ZXMP M900 (V2.20) Hardware Manual

FIGURE 130 OPTICAL CONNECTION OF OP BOARD (O A SHARED CONFIGURATION MODE)


OTU OTU OTU OTU OTU OTU OTU

1 2 3
. . . n

A direction line 1

O M D

EOBA
A direction line 2

EOPA

O D U

1 2

OTU OTU OTU OTU OTU OTU OTU

3.
n
. .

1 2 3 n
. . .

O P
B direction line 1

O P EOBA
B direction line 2

O D U

EOPA

O M U

1 2 3
. . .

OTU

n
Line 2 - Protection channel

OTU

Line 1 - Working channel

Transmitting end: TIN interface of OP board is connected to OUT interface of EOBA board. TOUT1 and TOUT2 interfaces are connected to line fibers on the working channel and the protection channel respectively. Receiving end: ROUT interface of OP board is connected to IN interface of EOPA board. RIN1 and RIN2 interfaces are connected to line fibers of ODU boards on the working channel and the protection channel respectively. EOA redundancy mode In this mode, a pair of transmitter and receiver OTU type boards is configured on the working channel and the protection channel respectively. OP boards are located before transmitting-end OTU board in optical terminal and after receiving-end OTU board, as shown in Figure 131.
FIGURE MODE) 131 OPTICAL CONNECTION OF OP BOARD (EO A REDUNDANCY CONFIGURATION

OTU OTU OTU OTU OTU OTU OTU OTU


n n

EOBA O M D O P EOPA O D U EOPA

A Direction line 1

EOP A EOPA O P O D U
n

OTU OTU OTU OTU OTU O M U


n

EOBA

A Direction line 2

B Direction line 1

EOBA EOBA

OTU OTU OTU

B Direction line 2

Line1-Working channel

Line 2-Protection channel

254

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Transmitting end: TIN interface of OP board is connected to OUT interface of OMU board. TOUT1 and TOUT2 interfaces are connected to IN interface on the working channel and the protection channel respectively. Receiving end: ROUT interface of OP board is connected to IN interface of ODA board. RIN1 and RIN2 interfaces are connected to OUT interface on the working channel and the protection channel respectively.

Performance and Alarm Messages


The performance and alarm messages are listed in Table 125.
T AB L E 1 2 5 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OP B O AR D

Type Performance

Item Working channel input optical power Protection channel input optical power No working channel input optical power Low working channel input optical power No protection channel input optical power Low protection channel input optical power Optical switch failure Optical switch protection switching Optical switch restoring

Remark When OP board receives two different switching commands in 50 ms, it will only perform the first switching and report alarm to EMS.

Alarm

Event Repeat switching event

OPMS Board
Functions
OPMS (Optical Protect for Mux Section) board is used to implement the optical multiplex section shared protection function. Two types of OPMS board are available: OPMSS board with preventing resonance switch and OPMSN without preventing resonance switch.

Confidential and Proprietary Information of ZTE CORPORATION

255

ZXMP M900 (V2.20) Hardware Manual

Operating Principle
Figure 132 illustrates the operating principle of OPMS board.
FIGURE 132 OPERATING PRINCIPLE OF OPMS BOARD

Working channel A direction Protection channel Optical Swich Controlling Unit Working channel Protection channel

Working channel Protection channel B direction

Working channel Protection channel

Checking and Controlling Circuit

OPMS board performs the protection switching when it receives the switching command sent by the APS controller of OSCF/APSF board. It also accepts and conducts the forcible switching or recovery command sent from NCPF board. The protection switching and recovery is implemented by the optical switch in OPMS board.

Front Panel: Interfaces and Indicators


The front panel of OPMS board is shown in Figure 133.

256

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 133

FRONT PANEL OF OPMS BOARD

1. Running and alarm indicators 2. Laser warning sign 3. Optical switch status indicator 4. Optical interface

Table 126 describes the front panel and related information for basic operations of the OPMS board.
TABLE 126 FRONT PANEL DESCRIPTIONS OF OPMS BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID NOM Indicator ALM STA Laser warning sign ARO ARI1

OPMS OPMS Running indicator, green Alarm indicator, red Optical switch status indicator, bi-color (red-green) Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. A-direction red-ribbon output optical interface SC/PC connector A-direction local red-ribbon input optical interface SC/PC connector

Optical interface

Confidential and Proprietary Information of ZTE CORPORATION

257

ZXMP M900 (V2.20) Hardware Manual

Board Item Optical interface BRO1 BRI ABO BRI1 ARO1 BBI ARI BBO1 ABI1 BRO ABI ABO1 BBI1 BBO Number of occupied slot

OPMS B-direction local red-ribbon output optical interface SC/PC connector B-direction red-ribbon input optical interface SC/PC connector A-direction blue-rippon output optical interface SC/PC connector B-direction local red-ribbon input optical interface SC/PC connector A-direction local red-ribbon output optical interface SC/PC connector B-direction blue-ribbon input optical interface SC/PC connector A-direction red-ribbon input optical interface SC/PC connector B-direction local blue-ribbon output optical interface SC/PC connector A-direction local blue-ribbon input optical interface SC/PC connector B-direction red-ribbon output optical interface SC/PC connector A-direction blue-ribbon input optical interface SC/PC connector A-direction local blue-ribbon output optical interface SC/PC connector B-direction local blue-ribbon input optical interface SC/PC connector B-direction blue-ribbon output optical interface SC/PC connector 2


Slots for board

All slots in OTU subrack Slots in OA subrack except slot 6-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Operation precautions

Table 127 lists the relationship between the board status and the status of corresponding indicators.

258

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

OF

TABLE 127 RELATIONS BETWEEN THE WORKING STATUS AND INDICATOR STATUS OPMS BOARD

Working Status Waiting for configuration Running normally Alarming Initializing

Indicator Status NOM (Green) ALM (Red) STA (Bi-color) OFF OFF

The green indicator and the red indicator flash alternately. Flashing slowly and regularly Flashing slowly and regularly OFF ON

The green indicator and the red indicator flash quickly three times. The green indicator and the red indicator flash quickly at the same time. Flashing slowly and regularly Flashing slowly and regularly -

Downloading status A-direction switching alarm B-direction switching alarm

OFF Continuously lit in red Continuously lit in green

Note: The - symbol means that the indicator status is indefinite.

Performance and Alarm Messages


OPMS board has only event messages as listed in Table 129.
TABLE 128 EVENT MESSAGES OF OPMS BOARD

Type Performance Alarm Event

Item Control optical switch for status switching Online upgrade of software

Configuration of OPMS Board


During the configuration of multiplex section shared protection, wavelengths carrying services should be different. Working wavelengths and protection wavelengths of outer ring and inner ring should be assigned symmetrically. For example, 16 wavelengths (192.1 THz to 193.8 THz) are used as working wavelengths of outer ring, while 16 wavelengths (194.3 THz to 196.0 THz) are used as working wavelengths of inner ring. As shown in Figure 134, a pair of services is transmitted between node A and node B.

Confidential and Proprietary Information of ZTE CORPORATION

259

ZXMP M900 (V2.20) Hardware Manual

FIGURE 134

CONFIGURATION FOR MULTIPLEX SECTION SHARED PROTECTION

21(B A) B 21(B A ) 43(A B)

43 (A B )

43(E F) E 43(E F) 21(F E)

21(F E)

The service from node B to node A is carried by wavelength 21 (outer ring) while the service from node A to node B is carried by wavelength 43 (inner ring). In this way, the working wavelength 21 and 43 can be used repeatedly between other nodes in the ring network. The wavelength 21 on the inner ring can act as the protection wavelength of the wavelength 21 on the outer ring. Similarly, the wavelength 43 on the outer ring can act as the protection wavelength of the wavelength 43 on the inner ring, so as to implement the shared protection of multiple services on the network. To configure the multiplex section shared protection, an OPMS board with preventing resonance switch (OPMSS) should be configured at least in the ring to prevent self-excitation in the ring.

OPCS Board
Functions
OPCS (Optical Protect for Channel Section) board is used to implement the optical channel shared protection of ZXMP M800 equipment. It detects channel faults and performs optical channel switching once some fault occurs in the optical line.

Operating Principle
Figure 135 illustrates the operating principle of OPCS board.

260

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 135

OPERATING PRINCIPLE OF OPCS BOARD

Working channel Protection channel A direction Working channel Protection channel A-direction added wavelength A-direction dropped wavelength Optical Switch Controlling Unit

Working channel Protection channel Working channel Protection channel B-direction added wavelength B-direction dropped wavelength B direction

Checking and Cotnrolling Circuit

OPCS board receives and executes the protection switching or recovery command sent from OSC/APS board. The protection switching and recovery is implemented by the optical switches in OPCS board.

Confidential and Proprietary Information of ZTE CORPORATION

261

ZXMP M900 (V2.20) Hardware Manual

Front Panel: Interfaces and Indicators


The front panel of OPCS board is shown in Figure 136.
FIGURE 136 FRONT PANEL OF OPCS BOARD

1. Running and alarm indicators 2. Optical switching status indicator 3. Optical interface 4. Laser warning sign 5. Laser class sign

Table 129 describes the front panel and related information for basic operations of the OPCS board.
TABLE 129 FRONT PANEL DESCRIPTIONS OF OPCS BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID NOM Indicator


[Note]

OPCS OPCS Running indicator, green Alarm indicator, red Optical switch status indicator, bi-color (red-green) A-direction working signal output optical interface LC/PC connector

ALM STA AWO

262

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item Optical interface APO BWI Optical interface BPI AWI API BWO BPO AADD ADROP BADD BDROP

OPCS A-direction protection signal output optical interface LC/PC connector B-direction working signal input optical interface LC/PC connector B-direction protection signal input optical interface LC/PC connector A-direction working signal input optical interface LC/PC connector A-direction protection signal input optical interface LC/PC connector B-direction working signal output optical interface LC/PC connector B-direction protection signal output optical interface LC/PC connector A-direction working signal optical add interface LC/PC connector A-direction working signal optical drop interface LC/PC connector B-direction working signal optical add interface LC/PC connector B-direction working signal optical drop interface LC/PC connector Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OPCS board is CLASS 1 2

Laser warning sign

Laser class sign Number of occupied slot


Slots for board

All slots in OTU subrack Slots in OA subrack except slot 6-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging optical connectors while plugging/unplugging the board. Always keep optical connectors clean. Put on the dust caps for unused optical connectors in time.

Operation precautions

Note: The relations between the working status and corresponding indicator status of OPCS board are same as those of OPMS board. Please refer to Table 127 for detailed description.

Confidential and Proprietary Information of ZTE CORPORATION

263

ZXMP M900 (V2.20) Hardware Manual

Performance and Alarm Messages


The performance, alarm and event messages of OPCS board are listed in Table 130.
TABLE 130 PERFORMANCE, ALARM AND EVENT MESSAGES OF OPCS BOARD

Type Performance

Item Input optical power of A-direction working channel Input optical power of B-direction working channel Low input power of A-direction working channel

Alarm

No input power of A-direction working channel Low input power of B-direction working channel No input power of B-direction working channel

Event

Control optical switch for status switching Online upgrade of software

Configuration of OPCS Board


During the configuration of optical channel shared protection, wavelengths carrying services should be different. For example, a pair of services is transmitted between node A and node B, as shown in Figure 137.
FIGURE 137
H

CONFIGURATION FOR OPTICA CHANNEL SHARED PROTECTION


A

21(B A ) B 21(B A ) 22(A B)

22(A B)
G F

22(E F) E 22(E F) 21(F E)

21(F E)

The service from node B to node A is carried by wavelength 21 (outer ring) while the service from node A to node B is carried by wavelength 22 (inner ring). In this way, the working wavelength 21 and 22 can be used repeatedly between other nodes in the ring network. The wavelength 21 on the inner ring can act as the protection wavelength of the wavelength 21 on the outer ring. Similarly, the wavelength 22 on the outer ring can act as the protection wavelength of the wavelength 22 on the inner ring, so as to implement the shared protection of multiple services on the network.

264

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Although the wavelengths can be assigned flexibly, be sure that working wavelengths in two directions are different. For convenient debugging and maintenance, adjacent even and odd wavelengths are generally assigned to two directions respectively.

OMCP Board
Functions
The OMCP uses optical cross connection to implement traffic adding/dropping and protection switching with optical switch modules in it. Each OMCP board supports bidirectional channel 1:8 protection. Two cascaded OMCP boards support directional channel 1:16 protection.

Operating Principle
An OMCP board drives two optical switch modules at the same time. The operating principle of OMCP board is illustrated in Figure 138.
FIGURE 138 OPERATING PRINCIPLE OF OMCP BOARD

OUT0

IN8
. . .

22 optical switch 8

OUT8
. . .

Optical Switch Module

IN1 IN0

22 optical switch 1

OUT1

Control and Communication Unit

The OMCP board mainly consists of optical switch module and the control and communication unit. Optical switch module

Confidential and Proprietary Information of ZTE CORPORATION

265

ZXMP M900 (V2.20) Hardware Manual

Each optical switch module contains eight 22 optical switches. As shown in Figure 138, the channel from IN0 to OUT0 is the protection channel, while the channels from IN1/OUT1 to IN8/OUT8 are working channels. Working status Eight 22 optical switches are all in cross status. The IN0 is connected to OUT0; the IN1 is connected to OUT1, and so on. Protection status If the traffic i is interrupted due to failure of wavelength channel i (1i8), the OMCP board switches to protection status from working status when the traffic interruption is detected. The 22 optical switch i turns to straight-through status from cross status with other optical switches unchanged. In the protection status, the INi and OUTi are disconnected. The INi is connected to OUT0. Then the traffic i is transmitted through channel 0 to implement 1: N channel protection. In this case, the original traffic carried by channel 0 is discarded. Control and communication unit This unit monitors the power supply of the board. And it performs the board and EMS supervision function.

Front Panel: Interfaces and Indicators


The front panel of OMCP board is illustrated in Figure 139.

266

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 139 FRONT P ANEL OF OMCP BOARD

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

TABLE 131 FRONT P ANEL DESCRIPTIONS OF OMCP BOARD AND RELATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

OMCP OMCP

NOM ALM STA

Running indicator, green Alarm indicator, red Status indicator, bi-color (green and red), indicating switching status Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Working channel input interface of optical switch module A, n=1~8, corresponding to IN1-IN8 in Figure 138 Working channel output interface of optical switch module A, n=1~8, corresponding to OUT1-OUT8 in Figure 138 Protection channel input interface of optical switch module A, corresponding to IN0 in Figure 138 Protection channel output interface of optical switch module A, corresponding to OUT0 in Figure 138

Laser sign Optical interface

warning

AIn AOn API APO

Confidential and Proprietary Information of ZTE CORPORATION

267

ZXMP M900 (V2.20) Hardware Manual

Board Item BIn BOn BPI BPO Number occupied slot Laser class sign Slots for OMCP board of

OMCP Working channel input interface of optical switch module B, n=1~8 corresponding to IN1-IN8 in Figure 138 Working channel output interface of optical switch module B, n=1~8 corresponding to OUT1-OUT8 in Figure 138 Protection channel input interface of optical switch module B corresponding to IN0 in Figure 138 Protection channel output interface of optical switch module B corresponding to OUT0 in Figure 138 2 Indicates that the laser class of OMCP board is CLASS 1 All slots in OTU subrack Slots in OA subrack except slot 5-9 Slots in TMUX subrack except slot 7 and 8 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while


Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time. When the faulty channel recovers, the traffic can only be switched back to the channel in EMS manually. Since the insertion loss of protection interfaces (IN0/OUT0) of OMCP board is greater than that of other interfaces, make sure that the input power of transmitting end OTU and the output power of receiving end OTU of traffic 0 are in the normal optical power range.

TABLE 132 CORRESPONDENCE RELATIONS BETWEEN THE WORKING STATUS AND INDICATOR STATUS OF OMCP BOARD

Working Status The Bootrom program is downloaded. The board is waiting for configuration. The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. The board is performing self-test upon power on. The board is in downloading status. the

Indicator Status NOM (Green) Off ALM (Red) Off STA (Bi-color) Off Off

The red indicator and the green indicator flash alternately. Flashing slowly and regularly Flashing slowly and regularly Off

On

The red indicator and the green indicator flash quickly for three times. The red indicator and the green indicator flash quickly at the same time. -

Off Off Glowing in red

The input of channel is

268

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Working Status switched. The output of channel is switched. Both the input and output of channel are switched at the same time.

Indicator Status NOM (Green) ALM (Red) STA (Bi-color)

Glowing in green

Glowing in orange

Note: For the bi-color indicator STA, when the red light and green light glows at the same time, it will be lighted in orange.

Optical Connections of OMCP Board


OMCP boards are located at both ends of channels to be protected, that is, before transmitting end OTU and after receiving end OTU. They are used in pairs. When both the transmitting end and the receiving end are configured with an OMCP board, the system can implement bidirection 1: N (N8) protection, as shown in Figure 140. Optical switch module A corresponds to channel connections in local transmitting direction, while optical switch module B corresponds to channel connections in local receiving direction. The relations between optical switch module and optical interfaces of OMCP board are described in Table 131.
FIGURE 140 OPTICAL CONNECTION OF OMCP BOARD (BIDIRECTIONAL 1:8 PROTECTION)
APO AI8 Client signal input API OMCP BPI OTU ODU OMU OTU OTU AO8 BO8 Client signal output BPO BI8 OTU AO8 BPI

OTU OTU OMU ODU

OTU

OTU

BI8

BO8 BPO OMCP API AI8

Client signal output

Client signal input

APO

As shown in Figure 140, at the transmitting end, client side signals are input to the OMCP board through input interfaces. The output interfaces of OMCP board are connected to client-side interfaces of OTU board. At the receiving end, the OMCP boards input interfaces are connected to client-side interfaces of OTU board while its output interfaces are connected to user equipment.

Confidential and Proprietary Information of ZTE CORPORATION

269

ZXMP M900 (V2.20) Hardware Manual

The system can implement bidirectional 1:N (N16) protection by cascading OMCP board (slave OMCP) with existing OMCP board (master OMCP), as shown in Figure 141.

FIGURE 141 OPTICAL CONNECTION OF OMCP BOARD (BIDIRECTIONAL 1:16 PROTECTION)

The dashed frame indicates a site. two slabe OMCPs in the same dashed frame belong to one OMCP board

Connect the APO/BPO interfaces of master OMCP to API/BIP interfaces of slave OMCP board correspondingly with optical fibers. At the transmitting end, client-side signals are connected to input interfaces of OMCP board. The output interfaces of OMCP board are connected to client-side interfaces of OTU board. At the receiving end, the input interfaces of OMCP board are connected to client-side interfaces of OTU board. The output interfaces of OMCP board are connected to user equipment.

270

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Performance and Alarm Messages


The OMCP board only has event messages as listed in Table 133.
T AB L E 1 3 3 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F O M C P B O AR D

Type Performance Alarm

Item Optical switch status switching

Event

Optical switch status restoring Optical switch failure

Control and Supervision Boards


Board ID NCP OSC OHP NCPF OSCF OHPF APSF PBX PWSB FCB Full Name NE Control Processor Optical Supervision Channel Overhead Processing Board NE Control Processor for Fast Ethernet Optical Supervision Channel for Fast Ethernet Overhead Processing Board for Fast Ethernet Automatic Protection Switching for Fast Ethernet Power Box Board Power Supervision Board Fan-Control Board Interface area of subrack Monitoring plug-in box Independent fan unit OA subrack Applicable Position

NCP Board
Functions and Operating Principle
NCP board is the NE control processor in 2 M supervision systems to implement all functions of NE supervision subsystem. It has the following functions: Collecting and processing alarm and performance messages of the NE where it is located, reporting these messages to the EMS and forwarding data received from other NCPs, receiving control commands issued by the EMS;

Confidential and Proprietary Information of ZTE CORPORATION

271

ZXMP M900 (V2.20) Hardware Manual

Storing configuration data. It can work separately without the EMS once it has been configured. Providing Qx and f interface for upper-layer management system. 10/100 M Ethernet electrical interface is used as Qx interface while RS232 interface is used as f interface (complying with V.28 protocol); Providing ECC route for communication with other NEs, and S interface for communication with other boards; Sending equipment alarms to PWSB board through alarm output interface; Receiving information about fan rotate speed, temperature of fan plug-in box sent from FCB board, reporting them to the EMS, and forwarding rotate speed adjustment command from the EMS to FCB board; Providing management function for multiple racks. One NCP board can manage four racks at most.

The operating principle of NCP board is illustrated in Figure 142.


FIGURE 142 OPERATING PRINCIPLE OF NCP BOARD

f interface Fan communication interface

ECC

Other NEs

FCB PWSB

MCU
Alarm output interface

Other boards

Database and Program

Qx

EMS

Front Panel: Interface and Indicators


The front panel of NCP board is shown in Figure 143.

272

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 143 FRONT P ANEL OF NCP BOARD

1. Running and alarm indicators 2. RS232 interface 3. Reset button

TABLE 134 FRONT P ANEL DESCRIPTIONS OF NCP BOARD AND REL ATED BASIC OPERATIONS

Board Board ID Indicator Interface Reset button NOM ALM RS232 RST

NCP NCP Running indicator, green Alarm indicator, red DB9 socket (female), complying with V.28 protocol Reset NCP board Located at the PCB of NCP board Switch DIP2 to ON position to enter mandatory IP address status. The IP address of OSCF board is 192.192.192.11 Switch DIP1 and DIP8 to ON position to enter Probe & debugging status. Switch all pins to non-ON position to enter application program status.

DIP switch

S2


Number of occupied slot Slots for NCP board 1

Slot 8 in OA subrack

Confidential and Proprietary Information of ZTE CORPORATION

273

ZXMP M900 (V2.20) Hardware Manual

The indicator lights, NOM (green) and ALM (red), on the NCP board represents the running status of the NE. The working status and indicator status of the NCP(/NCPF) board are listed in is shown in Table 135.
TABLE 135 CORRESPONDENCE RELATIONS BETWEEN THE WORKING STATUS AND THE INDICATOR STATUS OF NCP/NCPF BOARD

Working/Debugging Status Working Status The system is lack of basic databases. The NCP/NCPF board has been equipped in the ZXWM M900; but it has not been configured in the EMS. The system runs normally or it is downloading a program to a board. Errors occur while the system is running. The NCP/NCPF board is started and initialized. The Agent program is downloaded to the NCP/NCPF board. Debugging Status Mandatory IP status (the DIP2 pin of the DIP switch S2 is set to ON) Probe & debugging status ( the DIP1 and DIP8 of the DIP switch S2 are set to ON)

Indicator Status NOM (Green) ALM (Red)

Off On Flashing Off

Flashing Flashing Off On green

The red indicator and indicator flash alternately.

The red indicator and green indicator flash at the same time.

Off On

On Off

274

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Performance and Alarm Messages


The performance and alarm messages of NCP board are listed in Table 136.
T AB L E 1 3 6 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F N C P B O AR D

Type Performance Alarm Event

Item Card dismount alarm Card mount alarm -

OSC Board
OSC board is used in 2 M supervision systems, mainly performing the following functions: Forwarding monitoring information carried by the supervision channel (1510 nm or 1625 nm) to NCP/NCPF board and OHP board, and implementing the conversion in the reverse direction. Implementing APS controller and automatic power reduction (APR) function In terms of different requirements, OSC board is divided into terminal OSC board (OSCT) and line OSC board (OSCL). OSCT board: processes supervision signal in one direction. It is applicable to OTM equipment. OSCL board: processes supervision signals in two directions. If two OSCL board are installed in an OA subrack, supervision signals in four directions can be processed at the same time. The OSCL board is applicable to OLA and OADM equipment.

Confidential and Proprietary Information of ZTE CORPORATION

275

ZXMP M900 (V2.20) Hardware Manual

Operating Principle
The operating principle of OSC board is illustrated in Figure 144.
FIGURE 144 OPERATING PRINCIPLE OF OSC BOARD

Optical supervision signal input

O/E Converter

Transcoder

Control and Communication Unit

Data Processng Unit

Optical supervision signal output

E/O Converter

Transcoder

At the receiving end, the OSC board receives optical supervision signal from its adjacent NE. After O/E conversion, code transform and data processing, it forwards the electrical signal to NCP/NCPF board and OHP board via the control and communication unit. At the transmitting end, the control and communication unit receives electrical signal from NCP/NCPF board and OHP board. After data processing, code transform and E/O conversion, the optical signal carrying supervision information is sent to the adjacent NE.

Front Panel: Interfaces and Indicators


The front panels of OSCL and OSCT board are illustrated in Figure 145.

276

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 145 FRONT P ANEL OF OSC BOARD

OSCL

OSCT

1. Running and alarm indicators 2. Optical interface 3. Laser warning sign 4. Laser class sign

TABLE 137 FRONT P ANEL DESCRIPTIONS OF OSC BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

OSCL OSCL

OSCT OSCT

NOM ALM

Running indicator, green Alarm indicator, red Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes.

Laser warning sign

Confidential and Proprietary Information of ZTE CORPORATION

277

ZXMP M900 (V2.20) Hardware Manual

Board Item IN OUT IN1 OUT1 IN2 OUT2 Number occupied slot of

OSCL Optical supervision signal input interface 1, LC/PC connector Optical supervision signal output interface 1, LC/PC connector Optical supervision signal input interface 2, LC/PC connector Optical supervision signal output interface 2, LC/PC connector 1

OSCT Optical supervision signal input interface, LC/PC connector Optical supervision signal output interface, LC/PC connector 1

Optical interface

Slots for OSC board

Slot 5 and slot 7 in OA subrack Master OSC board must be installed in slot 7 Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Note: The relations between the status of OSC board and corresponding status of indicators are same as those of the OTU board. Please refer to Table 31 for the detailed description.

Optical Connections of OSC Board


A pair of optical interfaces of OSC board transmits/receives the supervision information of a site. In a system with 80 channels or below, OSC boards are connected to SIN/SOUT interfaces of EOBA, EOPA and EOLA boards with optical fibers, as shown in Figure 146.

278

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 146 OPTICAL CONNECTION OF OSC BOARD


OTM
EAST Input

OLA EOBA EOLA EOPA

OTM
EAST Output

OMU

ODU

SOUT SIN OUT IN1

SIN SOUT OUT2 IN

OSCT
IN WEST Output SOUT SIN OUT1

OSCL
IN2 SOUT

OSCT
OUT SIN WEST Input

ODU EOPA EOLA EOBA

OMU

In a 160-channel system, OSC boards are connected to CSR/CST interfaces of OBM boards with optical fibers, as shown in Figure 73 in the section Optical Connections of OBM Board.

Performance and Alarm Messages


The performance and alarm messages of OSC board are listed in Table 138.
T AB L E 1 3 8 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OS C B O AR D

Type

Detection Point

Item Input optical power 15-min/24-hour background BE

Remark Default threshold: -48 dBm Default threshold: -45 dBm ES -

OSC sink port (optical interface) input

15-min/24-hour ES 15-min/24-hour SES 15-min/24-hour UAS 15-min/24-hour OOF times count

Performance

OSC source port (optical interface) Alarm (optical interface) output Output optical power

OSC sink port input

No input optical power alarm Low input optical power alarm LOF alarm UAS alarm SD alarm LOS alarm 15-min/24-hour over-threshold alarm

Confidential and Proprietary Information of ZTE CORPORATION

279

ZXMP M900 (V2.20) Hardware Manual

Type

Detection Point

Item 15-min/24-hour over-threshold alarm 15-min/24-hour over-threshold alarm 15-min/24-hour BE over-threshold alarm SES UAS count

Remark Default threshold: -10 dBm Default threshold: -7 dBm -

OSC source port (optical interface) output

No output optical power alarm Low output optical power alarm OSC RD (remote defect) alarm Loop locking succeeds/fails Segment locking succeeds/fails Protection locking succeeds/fails Switching succeeds/fails maneuver commands

Event

Protection switching port

Cleaning external succeeds/fails

Forcible switching succeeds/fails Line (loop) succeeds/fails Line (loop) succeeds/fails switching restoring

OHP Board
Functions and Operating Principle
OHP board processes orderwire data and transparent user channel data between sites in 2 M supervision systems. The operating principle of OHP board is illustrated in Figure 147.

280

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 147 OPERATING PRINCIPLE OF OHP BOARD

Signal tone generator

CODEC

CODEC

SLIC

2 audio interfaces

Time Division Switching Unit DTMF Signaling HDLC Conference telephone processing PCM clock

To OSC board

Control and Communication Unit

RS232 interface

RS422 interface

SLIC: HDLC: PCM: DTMF:

Subscriber Line Interface Circuit High-level Data Link Control Pulse Code Modulation Dual-Tone Multi-Frequency

Orderwire overhead information processing OHP board uses the circuit-switching mode to process speech and speech-related signaling. As shown in Figure 147, the time division switching unit, conference telephone processing unit, codec, SLIC, signal tone generator, PCM clock unit and signaling HDLC unit work together to implement the task. OHP board has the following functions related to orderwire data processing: Supporting three calling modes: selection call, group call and broadcast call; Being capable of communication crossing optical multiplex sections, that is, orderwire communication between different optical multiplex sections; Supporting orderwire interconnection in multiple directions (no less than four directions); Providing interfaces (audio interfaces) for main phone set and subsidiary phone set, which are located on the interface area of OA subrack. Both phone sets have same functions and can be used within the range of 200 m

Transparent user channel information processing OHP board processes transparent user channel information carried by optical supervision channel. It provides two user transparent channel interfaces, RS232 interface and RS422 interface.

Control and communication information processing

Confidential and Proprietary Information of ZTE CORPORATION

281

ZXMP M900 (V2.20) Hardware Manual

The control and communication unit receives supervision information from other modules and report it to the EMS. It also receives control commands from the EMS.

Front Panel: Interfaces and Indicators


The front panel of OHP board is shown in Figure 148.
FIGURE 148 FRONT P ANEL OF OHP BOARD

1. Running and alarm indicators

282

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 139 FRONT P ANEL DESCRIPTIONS OF OHP BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

OHP OHP

NOM ALM

Running indicator, green Alarm indicator, red 1 Slot 6 in OA subrack

Number of occupied slot Slots for OHP board

Note: The relations between the status of OHP board and corresponding status of indicators are same as those of the OTU board. Please refer to Table 31 for the detailed description.

Performance and Alarm Messages


The performance and alarm messages of OHP board are listed in Table 140.
T AB L E 1 4 0 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OHP B O AR D

Type Performance Alarm Event

Item Loss of clock source alarm Establishment of orderwire communication link establishment fails

NCPF Board
Operating Principle
NCPF board can be used as NE control processor in 2 M or 100 M supervision systems to implement NE-level network management function. It provides the following functions: Collecting and processing alarm and performance messages of other boards in equipment, and report them to the EMS; Storing configuration data. It can work separately without the EMS once it has been configured. Providing S interface for communication with other boards; Providing ECC route for communication with other NEs, and Qx and f interfaces for upper-layer management system;

Confidential and Proprietary Information of ZTE CORPORATION

283

ZXMP M900 (V2.20) Hardware Manual

In 2 M supervision systems, the implementation of ECC route and Qx interface is same as those of NCP board. In 100 M supervision systems, ECC route and Qx interface are provided by OSCF board. RS232 interface is adopted as f interface. It complies with V.28 protocol. Supporting standby route to ensure the transfer and exchange of supervision information when optical supervision channel fails; In a 2 M supervision system, the standby route is accessed to the system by a HUB. In a 100 M supervision system, the standby route is accessed to the system by an OSCF board. Providing alarm output interface to send equipment alarms to PWSB board; Receiving information about fan rotate speed, temperature of fan plug-in box sent from FCB board, reporting them to the EMS, and forwarding rotate speed adjustment command from the EMS to FCB board; Providing management function for multiple racks. An NCPF board can manage four racks. More NCPF boards are needed for the management of more than four racks. In this case, add HUB between OSCF board and NCPF board to enable the communication between NCPF boards and OSCF boards.

The operating principle of NCPF board in a 2 M supervision system is same as that of NCP board, as shown in Figure 142. The operating principle of NCPF board in a 100 M supervision system is illustrated in Figure 149.
FIGURE 149 OPERATING PRINCIPLE OF NCPF BOARD (100 M SUPERVISION SYSTEM)

FCB Other boards

Fan communiation interface S interface Alarm output interface f interface Standby route

MCU

Ethernet interface

OSCF

ECC Qx

Other NEs

PWSB

EMS

Database and Program

284

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Front Panel: Interfaces and Indicators


The front panel of NCPF board is shown in Figure 150.
FIGURE 150 FRONT P ANEL OF NCPF BOARD

1. Running and alarm indicators 2. Ethernet interface 3. RS232 interface 4. Reset button

TABLE 141 FRONT P ANEL DESCRIPTIONS OF NCPF BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

NCPF NCPF

NOM ALM

Running indicator, green Alarm indicator, red 10/100BASE-T interface, RJ45 socket In different supervision systems, the usage of this interface is different too. In 2 M supervision systems, it is used to connect EMS In 100 M supervision systems, it is used to connect Ethernet electrical interface of OSCF board

Interface

NET

RS232

DB9 socket (female), complying with V.28 protocol

Confidential and Proprietary Information of ZTE CORPORATION

285

ZXMP M900 (V2.20) Hardware Manual

Board Item Reset button RST

NCPF Reset NCPF board Located at the PCB of NCPF board

DIP switch

S2

of NCPF

Switch DIP2 to ON position to enter mandatory IP address status. The IP address of OSCF board is 192.192.192.11 Switch all pins to non-ON position to enter application program status.

Number occupied slot Slots board for

1 Slot 8 in OA subrack

Note: The relations between the status of NCPF board and corresponding status of indicators are same as those of NCP board. Please refer to Table 135 for the detailed description.

Performance and Alarm Messages


The performance and alarm messages of NCPF board are same as those of NCP board, as listed in Table 136.

OSCF Board
OSCF board is used in 100 M supervision systems to implement transfer and exchange of ECC data, orderwire and transparent user channel data, and APS information between NEs. It provides the following functions: Encapsulating ECC data, APS data, transparent user channel data and orderwire data between NEs in a 100 M supervision system into IP packets to implement transfer and exchange of these data; Providing six 10/100BASE-T electrical Ethernet interfaces with automatic crossover function. Through these interfaces, other boards (such as NCPF, OHPF and APSF), EMS, slave OSCF board and standby route can be accessed into the 100 M supervision system to implement the transfer of internal supervision information of a NE. Providing two 100BASE-FX or 10BASE-FL optical Ethernet interfaces for the accessing of 1510 nm or 1625 nm optical supervision channel to implement the transfer of supervision information between NEs. Use 10BASE-FL interfaces in 10 M supervision systems while use 100BASE-FX interfaces in 100 M supervision systems. Providing hardware-based layer 3 transfer capability Supporting dynamic routing with OSPF (open shortest path first) protocol adopted

286

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Operating Principle
The operating principle of OSCF board is illustrated in Figure 151.
FIGURE 151 OPERATING PRINCIPLE OF OSCF BOARD

Ethernet electrical interface 1 ~ 6

Route Switching Unit

Ethernet optical interface 1 OSC Ethernet optical interface 2

Control and Communication Unit

At the transmitting end, the OSCF board receives data packets from NCPF, APSF and OHPF board in the NE through Ethernet electrical interfaces. These data packets are forwarded to other NEs after being switched to corresponding Ethernet optical interfaces by the route switching unit. At the receiving end, the OSCF board receives data packets from other NEs through Ethernet optical interfaces. The route switching unit switches these data packets to corresponding Ethernet electrical interfaces according to the types, destination IP addresses and MAC addresses of these packets. Through these interfaces, the packets are forwarded to NCPF, APSF and OHPF board in the NE.

Front Panel: Interfaces and Indicators


The front panel of OSCF board is shown in Figure 152.

Confidential and Proprietary Information of ZTE CORPORATION

287

ZXMP M900 (V2.20) Hardware Manual

FIGURE 152 FRONT P ANEL OF OSCF BOARD

1. Running and alarm indicators 2. Optical interface status indicator 3. Optical interface 4. Ethernet electrical interface status indicator 5. Ethernet electrical interface 6. Laser alarm sign 7. Laser class sign

TABLE 142 FRONT P ANEL DESCRIPTIONS OF OSCF BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID NOM ALM STA Indicator

OSCF OSCF Running indicator, green Alarm indicator, red Indicates connection status and data receiving/transmitting status of optical interfaces, bi-color (green and red) Yellow indicator, located at the right top corner of each Ethernet electrical interface. It indicates connection status of Ethernet electrical interface Green indicator, located at the right bottom corner of each Ethernet electrical interface. It indicates data receiving/transmitting status of Ethernet electrical interface.

Optical interface

IN1 OUT1

Supervision signal 10BASE-FL or 100BASE-FX input interface 1, LC/PC connector Supervision signal 10BASE-FL or 100BASE-FX output interface 1, LC/PC connector

288

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item IN2 OUT2 Ethernet electrical interface

OSCF Supervision signal 10BASE-FL or 100BASE-FX input interface 2, LC/PC connector Supervision signal 10BASE-FL or 100BASE-FX output interface 2, LC/PC connector 10/100BASE-T interface with automatic crossover function, RJ45 socket. They are connected to NCPF, APSF, OHPF, slave OSCF board, standby route or EMS computer. Do not look at optical interfaces directly while plugging/unplugging fiber pigtails to avoid burning eyes. Indicates that the laser class of OPM board is CLASS 1 Located at the PCB of OSCF board Switch DIP2 to ON position to enter mandatory IP address status. The IP address of OSCF board is 192.192.192.11 Switch DIP1 and DIP8 to ON position to enter Probe & debugging status. Switch all pins to non-ON position to enter normal running status.

1~6

Laser warning sign Laser class sign

DIP switch

S2


Number occupied slot of 1 Slots board for OSCF

For two or less optical directions, insert an OSCF board in slot 7 of OA subrack For three or more optical directions, insert the master OSCF board into slot 7 of OA subrack and other OSCF boards into any other spare slots of OA subrack. Avoid damaging the fiber plugging/unplugging the board. pigtail connector while

Operation precautions

Always keep the optical connectors clean. Put on the dust caps for the unused optical connectors in time.

Table 143 describes the running status of the board and corresponding indicators status.
TABLE 143 CORRESPONDENCE RELATIONS BETWEEN THE WORKING STATUS AND THE INDICATOR STATUS OF OSCF BOARD

Working/Debugging Status Working Status The board is waiting for configuration. The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. Board initialization

Indicator Status NOM (Green) ALM (Red)

The red indicator and the green indicator flash alternately. It flashes regularly. It flashes regularly. On slowly slowly and and Off On It flashes

Confidential and Proprietary Information of ZTE CORPORATION

289

ZXMP M900 (V2.20) Hardware Manual

Working/Debugging Status

Indicator Status NOM (Green) ALM (Red) slowly regularly. and

The board is downloading.

waiting

for

program

The red indicator and the green indicator flash quickly at the same time. The red indicator and the green indicator flash slowly and regularly at the same time.

The board is in the program downloading status. Debugging Status The board is running the Boot program in the mandatory IP status. (the DIP2 pin of the DIP switch S2 is set to ON) Probe & debugging status ( the DIP1 and DIP8 of the DIP switch S2 are set to ON) Note:

Off

On

On

Off

Both the DIP switch S2 and the Ethernet electrical interface for debugging are located on the PCB of the OSCF board. When the board is in the debugging status, the STA indicator light and Ethernet electrical interface indicator lights of the OSCF board are all blacked out.

Table 144 describes the working status of optical/electrical interfaces of the OSCF board and corresponding indictors status.

TABLE 144 CORRESPONDENCE RELATIONS BETWEEN THE WORKING STATUS AND THE INDICATOR STATUS OF THE OPTICAL/ELECTRICAL INTERFACES ON OSCF BOARD

Indicator Status Working Status Ethernet Electrical Interface Indicator (Yellow) Ethernet Electrical Interface Indicator (Green) -

STA (Bi-color)

The optical interface 1 is connected while the optical interface 2 is unconnected. The optical interface 1 is sending and receiving data packets; while the optical interface 2 is unconnected. The optical interface 2 is connected while the optical interface 1 is unconnected. The optical interface 2 is sending and receiving data packets; while the optical interface 1 is unconnected. Both the optical interface 1 and 2 are connected.

Glowing in green.

Flashing in green.

Glowing in red.

Flashing in red.

Glowing in orange.

290

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Both the optical interface 1 and 2 are sending and receiving data packets. Both the optical interface 1 and 2 are unconnected. The Ethernet electrical interface is connected. The Ethernet electrical interface is unconnected.

Flashing in orange.

On Off On

Flashing

Note: For the bi-color indicator STA, when the red light and green light glows at the same time, it will be lighted in orange.

Configuration of OSCF Board


Optical Connections
When the transmission distance is short and span loss is less than 28 dB, use 100BASE-FX optical interfaces of OSCF board to transfer supervision information. In this case, the optical connection of OSCF board is same as that of OSCL board. Please refer to the section Optical Connections of OSC Board. When the transmission distance is short and span loss is between 28 dB and 42 dB, use 10BASE-FL optical interfaces to transfer supervision information. In this case, the optical connection of OSCF board is same as that of OSCL board. Please refer to the section Optical Connections of OSC Board. When the transmission distance is long and span loss is more than 42 dB, use 100BASE-FX optical interfaces of OSCF board and OTU boards together to transfer supervision information. In this case, an operating wavelength in the DWDM system will be occupied. Taking unidirectional supervision channel as example, Figure 153 illustrates optical connection relations of OSCF boards.
FIGURE 153 OPTICAL CONNECTION BETWEEN OSCF BOARD AND OTU BOARD
Long-distance transmission OMU EOBA EOP A ODU

OSCF

OTU OTU

OTU OTU

OSCF

OTU

OTU

IN1/OUT1 interfaces or IN2/OUT2 interfaces of OSCF board are connected to client-side interfaces of OTU boards.

Confidential and Proprietary Information of ZTE CORPORATION

291

ZXMP M900 (V2.20) Hardware Manual

Note: OTU boards connected continuous-rate traffic.

to

OSCF

board

must

be

those

supporting

Network Cable Connections


Since the Ethernet electrical interfaces of OSCF board have automatic crossover function, OSCF board can be connected to other boards (NCPF, APSF, OHPF or slave OSCF board), standby router and EMS computer in 100 M supervision systems with crossover network cable or straight network cable.

Performance and Alarm Messages


The performance and alarm messages of OSCF board are listed in 145.
T AB L E 1 4 5 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OS CF B O AR D

Table

Type

Detection Point

Item Input optical power

Remark Only for 10BASE-FL optical interfaces Only for 10BASE-FL optical interfaces Only for 10BASE-FL optical interfaces. Default alarm threshold is -40 dBm. Only for 10BASE-FL optical interfaces -

OSC sink port (optical interface) input

15-min received massage 15-min sent data message 15-min lost data message 15-min CRC error packet

Performance

OSC source port (optical output interface)

Laser bias current Output optical power 15-min received massage

Network port (electrical interface 1-6) Alarm

15-min sent data message 15-min lost data message 15-min CRC error packet LOS alarm Low input optical power

OSC sink port

No input optical power 15-min CRC error packet over-threshold alarm 15-min message over-threshold alarm loss

292

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Type

Detection Point

Item Laser bias current over-threshold alarm

Remark Only for 10BASE-FL optical interfaces. Default alarm threshold is -10 dBm. Over 10 over-long/short packets in 15 minutes

OSC source port Laser failure alarm 15-min CRC error packet over-threshold alarm 15-min message over-threshold alarm Laser shut-down Laser start up Over-long packet over-threshold event Over-short packet over-threshold event loss

Network port

OSC source port Event OSC sink port and network port

OHPF Board
Operating Principle
OHPF board processes orderwire data and transparent user channel data between sites in 100 M supervision systems. The operating principle of OHPF board is illustrated in Figure 154.
FIGURE 154 OPERATING PRINCIPLE OF OHPF BOARD

CODEC
PCM

SLIC

2 audio interfaces

Voice processing

Time division switching

Conference telephone processing

Control and Communication Unit

PCM clock

10M/100M RS232 RS422 interface interface Ethernet interface

Confidential and Proprietary Information of ZTE CORPORATION

293

ZXMP M900 (V2.20) Hardware Manual

Orderwire overhead information processing OHPF board uses VoIP technology to process voice and voice-related signalings. It sends voice in IP packets to OSCF board, which will forward it to the destination NE. As shown in Figure 154, the voice processing unit, time division switching unit, conference telephone processing unit, codec, SLIC and PCM clock unit work together to implement the task. OHPF board has the following functions related to orderwire data processing: Supporting three calling modes: selection call, group call and broadcast call; Being capable of communication crossing optical multiplex sections; Supporting orderwire interconnection in multiple directions (no less than four directions); Providing interfaces (audio interfaces) for main phone set and subsidiary phone set, which are located on the interface area of OA subrack. Both phone sets have same functions and can be used within the range of 200 m

Transparent user channel information processing OHPF board provides two transparent user channel interfaces (RS232 interface and RS422 interface), which can receive and send data simultaneously.

Control and communication information processing OHPF board communicates with OSCF board through Ethernet interfaces shown in Figure 154. The control and communication unit receives supervision information from other modules and report it to the EMS. It also receives control commands from the EMS.

Front Panel: Interface and Indicators


The front panel of OHPF board is shown in Figure 155.

294

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 155 FRONT P ANEL OF OHPF BOARD

1. Running and alarm indicators 2. Ethernet interface 3. Reset button

TABLE 146 FRONT P ANEL DESCRIPTIONS OF OHPF BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID Indicator


[Note]

OHPF OHPF NOM ALM NET RST of OHPF Running indicator, green Alarm indicator, red 10/100BASE-T interface, RJ45 socket Connect it to Ethernet electrical interface of OSCF board Reset OHPF board 1 Slot 6 in OA subrack

Interface Reset button

Number occupied slot Slots for board

Confidential and Proprietary Information of ZTE CORPORATION

295

ZXMP M900 (V2.20) Hardware Manual

Note: The relations between the status of OHPF board and corresponding status of indicators are same as those of the OTU board. Please refer to Table 31 for the detailed description.

Performance and Alarm Messages


OHPF board has no performance and alarm messages but an event message, as listed in Table 147.
T AB L E 1 4 7 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F OHP F B O AR D

Type Performance Alarm Event

Item Establishment of orderwire communication link establishment fails

APSF Board
APSF board implements APS information management and switching control function in 2 M or 100 M supervision systems to ensure that APS data processing speed meet the requirement for APS switching time. It has the following functions: Managing APS information of multiple racks. Each APSF board can transfer APS information between four racks. In a 100 M supervision system, additional APSF boards are needed for more than four racks. Add a HUB between OSCF board and APSF board to enable the communication between them. Forwarding clock information to help CA board to access external clock and distribute clock unifiedly. Providing automatic power reduction (APR) function. Collecting and processing internal APS information of an NE, and forwarding APS information to other NEs through OSCF board. It acts as an APS protocol controller in 100 M supervision system.

296

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Operating Principle
The operating principle of APSF board is illustrated in Figure 156.
F I G U R E 1 5 6 O P E R A T I N G P R I N C I P L E O F AP S F B O A R D
Ethernet interface

To protection board

APS information processing

OSCF

To APSF board of other NES

From other boards

APS information collecting

RS232 interface

Control and Communication Unit

When the main optical channel in a system fails, APSF board collects APS information sent from each board. The APS information processing unit analyzes and processes the APS information and then forwards it to the APSF board of corresponding NE. It also informs the protection board to perform switching in specified time. The control and communication unit communicates with NCPF board through S interface. It provides an RS232 interface for debugging board.

Front Panel: Interfaces and Indicators


The front panel of APSF board is shown in Figure 157.

Confidential and Proprietary Information of ZTE CORPORATION

297

ZXMP M900 (V2.20) Hardware Manual

FIGURE 157 FRONT P ANEL OF APSF BOARD

1. Running and alarm indicators 2. Ethernet interface 3. RS232 interface 4. Reset button

TABLE 148 FRONT P ANEL DESCRIPTIONS OF APSF BOARD AND REL ATED BASIC OPERATIONS

Board Item Board ID NOM Indicator ALM STA NET Interface RS232 Reset button RST

APSF APSF Running indicator, green Alarm indicator, red Switching status indicator, bi-color (green and red) 10/100BASE-T interface, RJ45 socket Connect to Ethernet electrical interface of OSCF board DB9 socket (female) Output debugging information of board Reset APSF board 1 Slot 9 in OA subrack

Number of occupied slot Slots for APSF board

298

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Table 149 describes the working status of the board and corresponding indicator status.
TABLE 149 CORRESPONDENCE RELATIONS BETWEEN THE WORKING STATUS AND THE I N D I C A T O R S T A T U S O F AP S F B O A R D

Indicator Status Working Status The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. Board initialization NOM (Green) Flashing slowly and regularly Flashing slowly and regularly On ALM (Red) Off On Flashing slowly and regularly STA (Bi-color) -

The board is waiting for program downloading. The board is in downloading status. No protection configured. The protection mode of the first protection group is the channel ring shared protection or the MS ring shared protection group the program

The red indicator and the green indicator flashes quickly at the same time. The red indicator and the green indicator flashes slowly and regularly at the same time. -

has

been

Off Off Glowing in red Glowing green Glowing orange Off Glowing in red Glowing green Glowing orange in in in in

No switching A-direction switching B-direction switching Straight through No switching

The protection mode of the first protection group is the 1:N channel protection

Adding switching Dropping switching Adding/Dropping switching

Note: For the bi-color indicator STA, when the red light and green light glows at the same time, it will be lighted in orange.

Performance and Alarm Messages


APSF board has no performance and alarm message.

Confidential and Proprietary Information of ZTE CORPORATION

299

ZXMP M900 (V2.20) Hardware Manual

PBX Board
PBX (Power Box) board provides the following two functions: Processing active and standby power supply provided by the power distribution subrack and powering boards in the subrack where it is located; Monitoring input/output voltage of the subrack under-voltage/over-voltage alarms to the EMS. and reporting

Operating Principle
The operating principle of PBX board is illustrated in Figure 158.
FIGURE 158 OPERATING PRINCIPLE OF PBX BOARD

PBX board 2

Power alarm

Voltage separation detection Soft start Balance


Power supply for subrack

Standby DC

Reverse connection protection

Active DC

Reverse connection protection

Soft start Voltage separation detection

Balance

PBX board 1

Power alarm

Subrack power supply The active and standby DC power supplies are input to the PBX boards through air switches on the power distribution subrack and power sockets in interface areas of OA/OTU/TMUX subrack. The active power supply is input to PBX1 board in the upper slot of interface area while the standby power supply is input to PBX2 board in the lower slot in interface area. After the processing of reverse connection protection, soft start and balance output, the power is supplied to other boards in slots of the subrack through power sockets on the backplane.

Alarm report

300

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

The voltage separation detection unit monitors input/output voltage and sends the monitoring signal to PWSB board through the power alarm interface in interface area of OA/OTU/TMUX subrack.

Front Panel and Rear Panel


The front panel and rear panel of PBX board are shown in Figure 159.
FIGURE 159 FRONT P ANEL AND REAR P ANEL OF PBX BOARD

1. Indicators 2. Power socket 3. Signal interface

TABLE 150 PANEL DESCRIPTIONS OF PBX BOARD AND RELATED B ASIC OPERATIONS

Board NOM Indicator OV UV

PBX Running indicator, green When the board runs normally, it glows in green Over-voltage alarm indicator, red When an over-voltage alarm is detected, the OV indicator will be lit. Under-voltage alarm indicator, red When an under-voltage alarm is detected, the UV indicator will be lit. It is located on the rear panel of PBX board. The socket is secured with three screws. The left and right short screws are for -48 V, while the middle long screw is for the ground GND. It is located on the rear panel of PBX board, including address wires and output wire for power alarm signal PBX board is mounted in the PBX plug-in box on subrack. Each subrack has two PBX plug-in boxes, as shown in Figure 11 and Figure 18.

Power socket

Signal interface Slots for PBX board

Confidential and Proprietary Information of ZTE CORPORATION

301

ZXMP M900 (V2.20) Hardware Manual

Performance and Alarm Messages


The performance and alarm messages of PBX board are listed in Table 151.
T AB L E 1 5 1 P ER F O RM AN C E AN D AL AR M M ES S AG E S

Type Performance Alarm Event

Item Input voltage monitoring Output voltage monitoring -

PWSB Board
PWSB (Power Supervision) board provides the following functions: Automatically detecting the over-voltage and under-voltage status of output voltage of the subrack where it is located; Detecting voltage alarms of subracks and in-position status of PBX boards; Outputting audible and visual alarms and reporting them to the EMS; Sending equipment alarms to the first cabinet of row in equipment room.

The relation between PWSB board and power distribution subrack is illustrated in Figure 160.

302

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

FIGURE 160 RELATIONS BETWEEN PWSB BOARD AND POWER DISTRIBUTION SUBRACK

LED board

NCP/NCPF

LED

WARN BUS

External alarm input


ALM_IN

Subrack data interface Power alarm input from subracks

First cabinet of row

PWSB

ALM_OUT

SP_ALM 1-4 -48V

Air switch
DC1-1

DC1

Lightening protection and filter

DC1-6 DC2-1

DC2

Lightening protection and filter Power Distribution Subrack

DC2-6

Operating Principle
The operating principle of PWSB board is illustrated in Figure 161.
FIGURE 161 OPERATING PRINCIPLE OF PWSB BOARD

Alarm LED

DIP switch for cabinet No.

NCP/NCPF

Indicators on panel

FAN bus

Input equipment alarm

Control and Communication Unit


Total power alarm

Output equipment alarm

Power supply processing /detecting unit

External Subrack power alarm input alarm input

-48V 1

-48V 2

First cabinet in row

Confidential and Proprietary Information of ZTE CORPORATION

303

ZXMP M900 (V2.20) Hardware Manual

PWSB board consists of the control and communication unit, power supply processing/detecting unit and panel indicators. Power supply processing/detecting unit Two groups of -48 V power supply provided by power distribution subrack are input to the PWSB board through it. Each of the accessed two groups of power supply can act as either the active or standby one for the purpose of protection. After the voltage separation detection, the input power supply and total power alarm are sent to the control and communication unit. The power supply processing/detecting unit also provides the reverse connection protection and output balance functions. Panel indicators The indicators on panel of PWSB board are controlled by the control and communication unit, indicating alarm status of two groups of power supply. Control and communication unit It receives and processes power alarms of each subrack, 10 external input alarms and equipment alarms from NCP/NCPF board. The control and communication unit also controls the LED board and alarm output of the first cabinet of row.

Front Panel: Interfaces and Indicators


PWSB board is installed in the monitoring plug-in box of 1U height (as shown in Figure 26), which is located below the power distribution subrack (as shown in Figure 24). The front panel of PWSB board is shown in Figure 162.
FIGURE 162 FRONT P ANEL OF PWSB BOARD

1. Indicators (Nom, Alm, M_OV, M_UV, S_OV, S_UV) The relations between running status of PWSB board and status of indicators are described in Table 152.

304

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

TABLE 152 CORRESPONDING RELATIONS BETWEEN RUNNING STATUS AND INDICATOR STATUS OF PWSB BOARD

Indicators Working Status The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. Master power supply over-voltage alarm occurs. Master power under-voltage occurs. supply alarm NOM (green) Flashing slowly and regularly Flashing slowly and regularly Flashing slowly and regularly Flashing slowly and regularly Flashing slowly and regularly Flashing slowly and regularly ALM (red) Off M_OV (red) M_UV (red) S_OV (red) S_UV (red) -

On

On

On

Slave power supply over-voltage alarm occurs. Slave power under-voltage occurs. supply alarm

On

On

2. DIP switch for cabinet No. selection The 4-pin DIP switch is used to define the number of cabinet where PWSB board is located. It has no silkscreen ID on the front panel. Figure 163 illustrates the DIP switch. If the pin is set to ON position, it means the corresponding selection digit is 0. The definitions of cabinet No. are listed in Table 153.
FIGURE 163 DIP SWITCH ON PWSB BOARD
ON DIP

1 2 3 4

TABLE 153 DESCRIPTION OF CABINET NO.

DIP Cabinet No. Cabinet 0 (master) Cabinet 1 (extended) Cabinet 2 (extended) Cabinet 3 (extended)

1 Selection Digit 3 0 0 0 0

2 Selection Digit 2 0 0 0 0

3 Selection Digit 1 0 0 1 1

4 Selection Digit 0 0 1 0 1

Confidential and Proprietary Information of ZTE CORPORATION

305

ZXMP M900 (V2.20) Hardware Manual

3. -48_In1/-48_In2 The master/slave power supply input interfaces are used to connect the master/slave -48 V power supply from the power distribution subrack. They are type-D 3-pin DC power supply sockets, as shown in Figure 13. The definitions of pins are described in Table 154.
TABLE 154 DEFINITIONS OF PINS IN -48_IN1/-48_IN2 POWER SOCKET

Pin A1 A2 A3 -

Signal -48V GND PGND -48V Screws beside socket

Function -48 V ground Protection ground -48 V Protection ground

Signal Attribute Power supply Protection ground Power supply Protection ground

4. Alm_In It is a DB25 socket used as an external alarm input interface. Alarms from external monitoring equipment are input to PWSB board through this interface and displayed in the EMS. The input alarm signals are isolated with optical couplers or relays. Table 155 lists the definitions of pins of Alm_In socket.
TABLE 155 DEFINITIONS OF PINS IN ALM_IN SOCKET

Pin No. 1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22

Signal Name ALMIN1_C1 ALMINCOM_C0 ALMIN2_C1 ALMINCOM_C0 ALMIN3_C1 ALMINCOM_C0 ALMIN4_C1 ALMINCOM_C0 ALMIN5_C1 ALMINCOM_C0 ALMIN6_C1 ALMINCOM_C0 ALMIN7_C1 ALMINCOM_C0 ALMIN8_C1 ALMINCOM_C0 ALMIN9_C1 ALMINCOM_C0

Function External alarm input 1 + External alarm input 1 External alarm input 2 + External alarm input 2 External alarm input 3 + External alarm input 3 External alarm input 4 + External alarm input 4 External alarm input 5 + External alarm input 5 External alarm input 6 + External alarm input 6 External alarm input 7 + External alarm input 7 External alarm input 8 + External alarm input 8 External alarm input 9 + External alarm input 9 -

Signal Attribute Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated Optical coupler/relay isolated

306

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Pin No. 10 23

Signal Name ALMIN10_C1 ALMINCOM_C0

Function External alarm input 10 + External alarm input 10 -

Signal Attribute Optical coupler/relay isolated Optical coupler/relay isolated

5. Alm_Out The alarm output interface is a DB15 socket (male), as shown in Figure 164. It is connected to the first cabinet of its row or other monitoring unit out of the cabinet. Table 156 describes the definitions of pins in the Alm_Out socket.
FIGURE 164 DB15 SOCKET (M ALE)

15

TABLE 156 DEFINITIONS OF PINS IN ALM_OUT SOCKET

Pin No. 1 9 2 10 3 11 4 12 6 13 8 15 Note:

Signal Name BUZZ_OUT+ BUZZ_OUTS_ALARM+ S_ALARMG_ALARM+ G_ALARMALM_SET+ ALM_SETBGND BGND M_-48V M_-48V

Function Description Buzzer signal + Buzzer signal Critical alarm signal + Critical alarm signal Major alarm signal + Major alarm signal Alarm setting signal + Alarm setting signal -48 V ground -48 V ground -48 V output -48 V output

Signal Attribute On-off signal On-off signal On-off signal On-off signal On-off signal On-off signal On-off signal On-off signal -48 V ground -48 V ground -48 V -48 V

The signals (relay isolated) are sent from PWSB board to the first cabinet of its row. It depends on the connection of the alarm setting signals (ALM_SET+ and ALM_SET-) whether alarm signals are valid when they are connected or disconnected. If the ALM_SET+ and the ALM_SET- are disconnected, alarm signals are valid when the alarm signals are connected. It is determined before making cables on site.

Confidential and Proprietary Information of ZTE CORPORATION

307

ZXMP M900 (V2.20) Hardware Manual

6. Warn The internal alarm interface is a DB9 socket (female). It is connected to J3 interface of OA subrack. Signals, which are optical coupler isolated, are sent from NCP board. The DB9 socket is shown in Figure 15. The definitions of pins in Warn socket are described in Table 157.
TABLE 157 DEFINITIONS OF PINS IN W ARN SOCKET

Pin No. 1 6 2 7 3 8 4 9

Signal Name RING_C1 RING_C0 YELLOW_C1 YELLOW_C0 RED_C1 RED_C0 ALM_PWR_1+ ALM_PWR_1-

Function Ring control signal + Ring control signal Warning signal Warning signal Critical alarm signal Critical alarm signal Power alarm + Power alarm -

Signal Attribute Optical coupler isolated Optical coupler isolated Optical coupler isolated Optical coupler isolated Optical coupler isolated Optical coupler isolated Optical coupler isolated Optical coupler isolated

From/to

From NCP to PWSB

From PWSB to NCP

Note: The above table lists four pairs of on-off signal isolated by optical coupler or relay.

7. Led The alarm LED interface is a DB9 socket (female). The alarms are output to the LED board on the cabinet door through this interface. 8. Sp_Alm1-Sp_Alm4 For subrack power supply alarm sockets are available on PWSB board. They are DB9 sockets (female), which can be connected to J12 interface of OA subrack, J4 interface of OTU subrack or J12 interface of TMUX subrack. The definitions of pins are described in Table 158.
TABLE 158 DEFINITIONS OF PINS IN SP_ALM SOCKET

Pin No. 1 6 2 7 3 8 4 9

Signal Definition Vinu1 Vino1 ONLINE1 Voutu ALMCOM Vouto ONLINE2 Vino2

Descriptions Under-voltage alarm of subrack input power supply 1 Over-voltage alarm of subrack input power supply 1 Subrack PBX1 board in-position signal Under-voltage alarm of subrack output power supply Common alarm terminal Over-voltage alarm of subrack output power supply Subrack PBX2 board in-position signal Over-voltage alarm of subrack input power supply 2

308

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Pin No. 5

Signal Definition Vinu2

Descriptions Under-voltage alarm of subrack input power supply 2

9. Bus The local data interface is a type-D 36-pin in-line PCB soldered socket (female). It is the end interface of data bus of cabinet.

Performance and Alarm Messages


The performance and alarm messages of PWSB board are listed in Table 159.
T AB L E 1 5 9 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F PW S B B O AR D

Type Performance Alarm

Detection Point -

Item Subrack master power supply input under-voltage alarm Subrack master power supply input over-voltage alarm Subrack slave power under-voltage alarm Subrack slave power over-voltage alarm supply supply input input

Remark External types specified EMS alarm are in the

Board port

External alarm 1-10

4 subrack ports

Subrack master power supply input under-voltage alarm Subrack master power supply input over-voltage alarm Subrack master PBX board dismount alarm Subrack slave power under-voltage alarm Subrack slave power over-voltage alarm supply supply input input

Subrack slave PBX board dismount alarm Subrack power under-voltage alarm Subrack power over-voltage alarm supply supply output output

Confidential and Proprietary Information of ZTE CORPORATION

309

ZXMP M900 (V2.20) Hardware Manual

Type

Detection Point

Item Subrack power supply monitoring failure alarm Subrack power supply power down alarm

Remark -

Event

FCB Board
The FCB board provides the following functions. The FCB board monitors the running status of fans and temperature of the fan plug-in box, and then report the rotate speed and temperature to NCP/NCPF board. EMS queries the working status of fans and temperature of the fan plug-in box, and adjusts the rotate speed of fans automatically via NCP/NCPF and FCB boards If EMS disables the automatical speed adjustment function, or FCB board fails to communicate with the EMS, the FCB board will adjust rotate speed of fans if the temperature reported by its built-in temperature sensors is out of range, so as to lower the temperature. When the FCB board fails, it can not control fans anymore. The fans will be forced to run at full speed.

Front Panel
The structure of FCB board is illustrated in Figure 34, while Table 160 describes its front panel and related information for basic operations.
T A B L E 1 6 0 F R O N T P A N E L D E S C R I P T I O N S O F O AD B O A R D A N D R E L A T E D B A S I C O P E R A T I O N

Board Item NOM Indicator ALM

FCB Running indicator (green) located on the front panel of independent fan unit It flashes slowly and regularly when the FCB board runs normally. Alarm indicator (red) located on the front panel of independent fan unit The ALM indicator glows in red and the NOM indicator flashes slowly and regularly when the fan unit reports alarm. Provides - 48 V power for independent fan unit Carries fan bus from NCP board to FCB board

Power socket Signal interface

310

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Board Item Position Operation precautions

FCB The FCB board is installed in independent fan unit, as shown in Figure 22. When the FCB board fails, the fans will be forced to rotate at full speed.

Performance and Alarm Messages


The performance and alarm messages of the FCB board are listed in 161.
T AB L E 1 6 1 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F FCB B O AR D

Table

Type Performance Alarm Event

Item Fan rotate speed FCB temperature Fan failure -

Clock Board
Board ID CA CSU Full Name Clock Assignment Cross-switch and Synchronous-clock Unit Applicable Position TMUX subrack

CA Board
CA (Clock Assignment) board acts as SDH equipment clock in TMUX subrack, complying with ITU-T G.781 Recommendation. It has the following main functions: For input clocks of different level, the CA board monitors their quality and sorts them based on their priority. Then it selects an optimal clock as the reference clock source. The CA board supports two kinds of input clock, line clock and external clock.

Confidential and Proprietary Information of ZTE CORPORATION

311

ZXMP M900 (V2.20) Hardware Manual

Line clock: provided by convergence boards installed in TMUX subrack. The CA board supports 12 line clocks at most. External clock: provided by external BITS equipment. The CA board supports two 2 MHz and two 2 Mbit/s clocks.

The CA board generates clocks complying with ITU-T G.813 Recommendation and assigns them to other boards as reference line clock or external clock. The line clock is sent to convergence boards installed in TMUX subrack. And the CA board provides two 2 MHz and two 2 Mbit/s external clocks.

Operating Principle
The operating principle of CA board is illustrated in Figure 165.
FIGURE 165 OPERATING PRINCIPLE OF CA BOARD
Line extracted clock G.813

Clock selection unit

SEC clock processing unit

Clock assignment unit External clock processing unit

Interface board clock

External clock input

External clock processing unit

External clock output

Clock sent between active and standby CA board

Active/standby status control unit

Control and Communication Unit

The operating principles of clock input/output and active/standby switching of CA board are described below. Clock input/output The CA board receives clocks at different levels from convergence boards or external interfaces, and then forwards them to the clock selection unit or external clock processing unit for filtering. The filtered clocks are sent to the SEC clock processing unit, which selects the optimal clock and generates output clock complying with ITU-T G.813. Then the clock assignment unit distributes the generated clock to other boards as the reference clock, or sends it to the external clock processing unit, which outputs standard external clocks. The Synchronization Status Message (SSM) of clock is sent to other service boards in the subrack through the data bus on TMUX subrack backplane. Active/standby CA board switching Two CA boards can be installed in a TMUX subrack to implement the hot backup. In normal running status, only one of them acts as the active

312

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

board. The standby board is locked with the output clock of the active one so as to ensure the synchronization of output clock of active and standby CA boards. Both the EMS and the board itself can control the switching between active CA board and standby CA board. The EMS sends switching command to the board through the control and communication unit. In another way, when the active CA board is power down or its clock output fails, the active/standby status control unit of the board enables the switching automatically to ensure the reliability and correctness of system clock.

Front Panel: Interfaces and Indicators


The front panel of CA board is shown in Figure 166.
FIGURE 166 FRONT P ANEL OF CA BO ARD

1. Running and alarm indicators 2. Active/standby CA board indicator 3. Clock status indicator

TABLE 162 FRONT P ANEL DESCRIPTIONS OF C A BO ARD AND REL ATED BASIC OPER ATIONS

Board Item Board ID

CA CA

Confidential and Proprietary Information of ZTE CORPORATION

313

ZXMP M900 (V2.20) Hardware Manual

Board Item NOM ALM Indicator M/S CKS1 CKS2 Number occupied slot of

CA Running indicator, green Alarm indicator, red Active/standby CA board indicator, green Clock status indicator, green They indicate current clock running status of the system through different combination of indicator status. 1 Slot 7 or slot 8 in TMUX subrack

Slots for CA board

The CA board in slot 7 is the active board while that in slot 8 is the standby board by default.

The correspondence between CA board indicator and the boards running status is shown in Table 163.
TABLE 163 CORRESPONDENCE RELATIONS INDICATOR STATUS OF C A BOARD WORKING STATUS

BETWEEN

THE

AND

Indicator Status Working Status The Bootrom program is downloaded. The board is waiting for configuration. The board is running normally, and no alarm occurs. The board is running normally, and some alarm occurs. NOM (Green) Off ALM (Red) Off M/S (Green) CKS1 (Green) CKS2 (Green) -

The red indicator and the green indicator flash alternately. Flashing slowly and regularly Flashing slowly and regularly Off

On Flashing slowly and regularly

Board initialization

On

Board is download Board status in

waiting

for

The red indicator and the green indicator flash quickly at the same time. The red indicator and the green indicator flash slowly at the same time. -

downloading

The board is configured as the active CA board The board is configured as the standby CA board.

On Off

314

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Indicator Status Working Status The CA board runs in the clock lock mode (normal tracing). The CA board runs in the clock holdover mode. The CA board runs in the fast pull-in mode. The CA board runs in the clock free run mode. NOM (Green) ALM (Red) M/S (Green) CKS1 (Green) On CKS2 (Green) On

On Off Off

Off On Off

Confidential and Proprietary Information of ZTE CORPORATION

315

ZXMP M900 (V2.20) Hardware Manual

Performance and Alarm Messages


The performance and alarm messages of CA board are listed in Table 164.
T AB L E 1 6 4 P ER F O RM AN C E AN D AL AR M M ES S AG E S O F C A B O AR D

Type Performance Alarm

Item Loss of clock alarm CA board switching

Event

Clock source automatic switching Clock source manual switching Clock source forcible switching

CSU Board
Functions
CSU (Cross-switch and Synchronous-clock Unit) board acts as a clock and signal cross-connect processing unit. Generally, two CSU boards are mounted together in the TMUX subrack for use. CSU board provides the following functions. Cross-connection function CSU board receives the backplane service signals from various service boards installed in the same TMUX subrack, such as DSAE and SMU, cross-connects these signals and sends them to corresponding service boards. The cross-connection capacity is 4848 2.5 Gbit/s backplane signals. Clock function CSU board selects the optimal clock as the system clock from the input clocks at different levels according to certain algorithm. The input clock may be line clock, external clock or clock from the other CSU board in the TMUX board. Line clock: comes from various service boards in the TMUX subrack. Each service board provides one clock. Up to 12 channels of clocks are available. External clock: Provided by external BITS equipment. Two channels of 2 MHz and two channels of 2 Mbit/s clock signals are supported. Clock from the other CSU board: The other CSU board can output one channel of clock signal according to certain algorithm.

316

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

In addition, CSU board can convert the system clock into various clock signals and assign them to other service boards in the TMUX subrack as reference clock. These clock signals can also be output as external clocks or provided to the other CSU board. Line clock: It is output to all the other service boards in the TMUX subrack. For each service board, one channel of clock signal is provided. Up to 12 channels of output clock signals are available. External clock: Two channels of 2 MHz and 2 channels of 2 Mbit/s clock signals are output. Clock output to the other CSU board: One channel of clock signal is output to the other CSU board.

CSU board receives APS commands sent by APSF board to implement the protection switching at electronic layer.

Operating Principle
The operating principle of CSU board is illustrated in Figure 167.
FIGURE 167 OPERATING PRINCIPLE OF CSU BOARD

48 channels of 2.5 Gbit/s backplane signals

Cross-connect unit

48 channels of 2.5 Gbit/s backplane signals

Master/slave switching control unit

Control & communication unit

Line clock External clock Clock from the other CSU board

Clock processing unit

Line clock External clock Clock to the other CSU board

CSU board consists of a cross-connect unit, a clock processing unit, a master/slave switching control unit and a control & communication unit, as described one by one below. Cross-connect unit This unit receives 48 channels of 2.5 Gbit/s backplane traffic signals from 12 service boards in the TMUX subrack, i.e. each service board provides 4 channels of 2.5 Gbit/s backplane traffic signals, cross-connects these signals and sends the processed signals to corresponding service boards.

Confidential and Proprietary Information of ZTE CORPORATION

317

ZXMP M900 (V2.20) Hardware Manual

Clock processing unit This unit processes input clocks of various levels and then selects the optimal clock as the system clock from them according to certain algorithm. The input clocks may be line clocks extracted from service boards, external clock input from the external clock interface or the clock from the other CSU board. On the other hand, this unit can also converts the system clock into clock signals in various format and then assigns them to service boards in the TMUX subrack as reference clock, outputs them as external clock, or provides to the other CSU board.

Master/slave switching control unit Two CSU board can be mounted in the TMUX subrack for the purpose of hot backup. In normal situation, only one of them acts as the master board. The slave CSU board works in the locked mode so as to guarantee the consistence between the output clock phases of the master CSU board and the slave one.

Note: The master/slave concept only directs to the clock function of CSU board. The cross-connect units of both CSU boards work at the same time. Therefore, for service boards, the cross-connect unit is not classfied into master one or slave one.

The switching between master CSU board and slave CSU board can be controlled by the EMS or the board itself. The EMS issues the switching command to the board through the control & communication unit. The switching of CSU board is non-revertive. The prerequisite of successful switching is that the slave CSU board is working normally. When the master CSU board fails or it receives a switching command, the master/slave switching control unit will perform the switching automatically so as to ensure the reliability and validity of system clock. APS switching control unit TMUX subrack implements the function of protection switching at electronic layer. CSU board performs the commands sent by APS. APS control unit sends APS commands to both the master and slave CSU boards of TMUX subsystem, in order to realize the protection switching function. Control & communication unit This unit monitors the power supply of the board and implements the supervision of board and the EMS.

318

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Front Panel
The front panel of CSU board is shown in Figure 168.
FIGURE 168 FRONT PANEL OF CSU BOARD

1. Running and alarm indicators 2. Master/slave CSU board indicator 3. Clock status indicators

Table 165 describes the front panel and related information for basic operations of the CSU board.
TABLE 165 FRONT PANEL DESCRIPTIONS OF CSU BOARD AND RELATED OPERATION INFORMATION

Board Item Board ID NOM ALM Indicator M/S CKS1 CKS2

CSU CSU Running indicator, green Alarm indicator, red Master/slave board indicator, green Clock status indicator, green Indicates the current clock status of the system by different status combination of two indicators.

Confidential and Proprietary Information of ZTE CORPORATION

319

ZXMP M900 (V2.20) Hardware Manual

Board Item Number of occupied slot Slots for board

CSU 1 Slot 7 and 8 in TMUX subrack Slot 7 is used for master CSU board while slot 8 is used for slave CSU board by default.

Table 166 describes the relationship between the working status of CSU board and the status of indicators.
TABLE 166 RELATIONS BETWEEN THE WORKING STATUS AND INDICATOR STATUS CSU BOARD

OF

Working Status Downloading BootROM program Waiting for configuration Running normally

Indicator Status NOM (Green) OFF ALM (Red) OFF M/S (Green) CKS1 (Green) CKS2 (Green) -

The green indicator and the red indicator flash slowly alternately. Flashing slowly and regularly Flashing slowly and regularly ON OFF

Alarming

ON Flashing slowly and regularly

Initializing

Waiting for download

The green indicator and the red indicator flash quickly at the same time. The green indicator and the red indicator flash slowly at the same time. -

Downloading status Master CSU board Slave CSU board Locked (tracing normally) Hold-in Fast pull-in Free oscillation

ON OFF

ON ON OFF OFF

ON OFF ON OFF

320

Confidential and Proprietary Information of ZTE CORPORATION

Chapter 3 Boards

Note: The symbol - indicates indefinite status.

Performance and Alarm Messages


The performance, alarm and event messages of CSU board are listed in Table 167.
TABLE 167 PERFORMANCE, ALARM AND EVENT MESSAGES OF CSU BOARD

Type Performance Alarm

Item Board environment temperature Environment temperature alarm Loss of clock alarm MCU reset EEPROM data error

Event

CSU board switching Clock source automatic switching Clock source manual switching Clock source forced switching

Confidential and Proprietary Information of ZTE CORPORATION

321

ZXMP M900 (V2.20) Hardware Manual

322

Confidential and Proprietary Information of ZTE CORPORATION

Appendix

Optical Connections of ZXWM M900


This appendix introduces the optical fiber connections between boards in the ZXWM M900 through examples of 40/48/80/96/160/176-channel systems.

8/16/32/40/48-Channel System
The optical cable connections of 8, 16, 32, 40 and 48 channel systems are similar. Figure 169 illustrates the application of ZXWM M900 in a network and the optical fiber connection.
FIGURE 169 APPLICATION OF ZXWM M900 (NO MORE THAN 48-CHANNEL SYSTEM)
OTM OLA OADM OTM

OTU S1 ? 1
?

RM1 SD1 R1 RM2 SD2 R2 O M U OBA R' MPI-S S' OLA MPI-R OAD OPA O D U SDn-1 Rn-1 SDn Rn ????? OSCT OSCL OSCL OSCT OTU 1 OTU 2

OTU S2 ? 2
?

OTU n-1

Sn-1 RMn-1

??
??

OTU Sn n ?

RMn

O O T T U U

O O T T U U

OTU n-1 OTU n

OTU 1 OTU 2

R1 SD1

RM1

?
R2 SD2 O M U RM2 O D U Rn-1 SDn-1 Rn SDn R' MPI-S O O T T U U O O T T U U
?

S1

OTU 1 OTU 2

S2

?
?

OPA MPI-R S'

OLA

OAD

OBA

RMn-1 S n-1

OTU n-1 OTU n

??
??

OTU n-1 OTU n

RMn

Sn

??

Confidential and Proprietary Information of ZTE CORPORATION

323

ZXMP M900 (V2.20) Hardware Manual

Operating wavelength range: C-band (191.3 THz-196.0 THz) Channel spacing: 100 GHz

80/96-Channel System
Figure 170 illustrates the optical fiber connection in an 80/96-channel system consisting of ZXWM M900.
FIGURE 170 APPLICATION OF ZXWM M900 (80/96-CHANNEL SYSTEM)

Operating wavelength range: C-band (191.30 THz-196.05 THz) Channel spacing: 50 GHz

Note: In contrast to a 40-channel system, the 80-channel system adds OCI boards to combine wavelengths in C100_1 band and C100_2 band with the frequency spacing at 100 GHz into wavelengths in C50_1 band with the spacing at 50 GHz.

160/176-Channel System
Figure 171 illustrates the optical fiber connection in a 160/176-channel system consisting of ZXWM M900.

324

Confidential and Proprietary Information of ZTE CORPORATION

Appendix A Optical Connections of ZXWM M900

FIGURE 171 APPLICATION OF ZXWM M900 (160/176-CHANNEL SYSTEM)

OTM1
OTU

OLA

OTM2
ODU ( C10 0_1) OCI ( C50 _1) ODU
( C100_ 2) OTU

. .

OMU ( C10 0_1) OCI ( C50 _1) EOBA DCM


100km G.652

OPM VGSC EOBA OPM


100km G.652

. .

OTU

DCM EOPA EOBA

VGSC

. .

OMU
( C100_ 2)

EOPA

OTU

. .

OTU

. .

OMU ( L100_ 1)

O S C

OBM ( C/L)

OBM ( C/L)

O S C

OBM ( C/L)

OBM ( C/L)

O S C

ODU ( L100_ 1) OCI ( L50 _1) EOBA DRA DCM EOPA EOBA VGSC OPM DRA DCM EOPA EOBA OPM VGSC OCI ( L50 _1) ODU
( L100_ 2)

OTU

. .

OTU

. .

OMU
( L100_ 2)

OTU

. .

Operating wavelength range: C-band (191.30 THz-196.05 THz) L-band (186.95 THz-190.90 THz)

Channel spacing: 50 GHz

Note: In contrast to an 80/176-channel system, the 160/176-channel system adds additional OBM boards in OTM and OLA equipment. The OBM board in OTM combines or separate signals in L band. The OBM board in OLA multiplexes/demultiplexes signals in C+L band so as to amplify signals in different band separately.

Requirements on Operating Wavelength


The operating wavelengths of ZXWM M900, which employs the specific central wavelengths in multi-channel systems as its operating wavelengths, comply with ITU-T G.692 strictly. All the line-side interfaces of optical transponder boards, the aggregate interfaces of convergence boards (SRM /GEM/DSA) and the channel interfaces of add/drop boards meet the wavelength requirements specified in this appendix.

Wavelength Allocation in 8/32/40-Channel Systems


8/32/40 Wavelength System
Table 168 lists the wavelength allocation in a system consisting of ZXWM M900 with 40 wavelengths in C band. The spacing between wavelengths is 100 GHz.

Confidential and Proprietary Information of ZTE CORPORATION

325

ZXMP M900 (V2.20) Hardware Manual

TABLE 168 WAVELENGTH ALLOCATION (8/32/40 CHANNEL, C BAND)

S/ N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Sub-ba nd Name C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1

Central Frequen cy (THz) 192.1 192.2 192.3 192.4 192.5 192.6 192.7 192.8 192.9 193.0 193.1 193.2 193.3 193.4 193.5 193.6 193.7 193.8 193.9 194.0

Central Waveleng th (nm) 1560.61 1559.79 1558.98 1558.17 1557.36 1556.55 1555.75 1554.94 1554.13 1553.33 1552.52 1551.72 1550.92 1550.12 1549.32 1548.51 1547.72 1546.92 1546.12 1545.32

S/ N 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

Sub-ba nd Name C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1 C100_1

Central Frequen cy (THz) 194.1 194.2 194.3 194.4 194.5 194.6 194.7 194.8 194.9 195.0 195.1 195.2 195.3 195.4 195.5 195.6 195.7 195.8 195.9 196.0

Central Waveleng th (nm) 1544.53 1543.73 1542.94 1542.14 1541.35 1540.56 1539.77 1538.98 1538.19 1537.40 1536.61 1535.82 1535.04 1534.25 1533.47 1532.68 1531.90 1531.12 1530.33 1529.55

48/96 Wavelength System


TABLE 169 WAVELENGTH ALLOCATION (48/96 CHANNEL, C BAND)

S/N 1 2 3 4 5 6 7

Sub-band Name C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2

Central Frequenc y (THz) 196.05 196.00 195.95 195.90 195.85 195.80 195.75

Central Wavelengt h (nm) 1529.16 1529.55 1529.94 1530.33 1530.72 1531.12 1531.51

S/N 49 50 51 52 53 54 55

Sub-band Name C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2

Central Frequenc y (THz) 193.65 193.60 193.55 193.50 193.45 193.40 193.35

Central Wavelengt h (nm) 1548.11 1548.51 1548.91 1549.32 1549.72 1550.12 1550.52

326

Confidential and Proprietary Information of ZTE CORPORATION

Appendix A Optical Connections of ZXWM M900

S/N 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46

Sub-band Name C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1

Central Frequenc y (THz) 195.70 195.65 195.60 195.55 195.50 195.45 195.40 195.35 195.30 195.25 195.20 195.15 195.10 195.05 195.00 194.95 194.90 194.85 194.80 194.75 194.70 194.65 194.60 194.55 194.50 194.45 194.40 194.35 194.30 194.25 194.20 194.15 194.10 194.05 194.00 193.95 193.90 193.85 193.80

Central Wavelengt h (nm) 1531.90 1532.29 1532.68 1533.07 1533.47 1533.86 1534.25 1534.64 1535.04 1535.43 1535.82 1536.22 1536.61 1537.00 1537.40 1537.79 1538.19 1538.58 1538.98 1539.37 1539.77 1540.16 1540.56 1540.95 1541.35 1541.75 1542.14 1542.54 1542.94 1543.33 1543.73 1544.13 1544.53 1544.92 1545.32 1545.72 1546.12 1546.52 1546.92

S/N 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94

Sub-band Name C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1 C100_2 C100_1

Central Frequenc y (THz) 193.30 193.25 193.20 193.15 193.10 193.05 193.00 192.95 192.90 192.85 192.80 192.75 192.70 192.65 192.60 192.55 192.50 192.45 192.40 192.35 192.30 192.25 192.20 192.15 192.10 192.05 192.00 191.95 191.90 191.85 191.80 191.75 191.70 191.65 191.60 191.55 191.50 191.45 191.40

Central Wavelengt h (nm) 1550.92 1551.32 1551.72 1552.12 1552.52 1552.93 1553.33 1553.73 1554.13 1554.54 1554.94 1555.34 1555.75 1556.15 1556.55 1556.96 1557.36 1557.77 1558.17 1558.58 1558.98 1559.39 1559.79 1560.20 1560.61 1561.02 1561.42 1561.83 1562.24 1562.64 1563.05 1563.46 1563.87 1564.27 1564.68 1565.09 1565.5 1565.91 1566.32

Confidential and Proprietary Information of ZTE CORPORATION

327

ZXMP M900 (V2.20) Hardware Manual

S/N 47 48

Sub-band Name C100_2 C100_1

Central Frequenc y (THz) 193.75 193.70

Central Wavelengt h (nm) 1547.32 1547.72

S/N 95 96

Sub-band Name C100_2 C100_1

Central Frequenc y (THz) 191.35 191.30

Central Wavelengt h (nm) 1566.73 1567.14

80/160 Wavelength System


TABLE 170 WAVELENGTH ALLOCATION (80 CHANNEL, C BAND)

S/N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Sub-band Name C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1

Central Frequenc y (THz) 196.05 196.00 195.95 195.90 195.85 195.80 195.75 195.70 195.65 195.60 195.55 195.50 195.45 195.40 195.35 195.30 195.25 195.20 195.15 195.10 195.05 195.00 194.95 194.90 194.85 194.80 194.75 194.70 194.65 194.60

Central Wavelengt h (nm) 1529.16 1529.55 1529.94 1530.33 1530.72 1531.12 1531.51 1531.90 1532.29 1532.68 1533.07 1533.47 1533.86 1534.25 1534.64 1535.04 1535.43 1535.82 1536.22 1536.61 1537.00 1537.40 1537.79 1538.19 1538.58 1538.98 1539.37 1539.77 1540.16 1540.56

S/N 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70

Sub-band Name C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1

Central Frequenc y (THz) 194.05 194.00 193.95 193.90 193.85 193.80 193.75 193.70 193.65 193.60 193.55 193.50 193.45 193.40 193.35 193.30 193.25 193.20 193.15 193.10 193.05 193.00 192.95 192.90 192.85 192.80 192.75 192.70 192.65 192.60

Central Wavelengt h (nm) 1544.92 1545.32 1545.72 1546.12 1546.52 1546.92 1547.32 1547.72 1548.11 1548.51 1548.91 1549.32 1549.72 1550.12 1550.52 1550.92 1551.32 1551.72 1552.12 1552.52 1552.93 1553.33 1553.73 1554.13 1554.54 1554.94 1555.34 1555.75 1556.15 1556.55

328

Confidential and Proprietary Information of ZTE CORPORATION

Appendix A Optical Connections of ZXWM M900

S/N 31 32 33 34 35 36 37 38 39 40

Sub-band Name C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1

Central Frequenc y (THz) 194.55 194.50 194.45 194.40 194.35 194.30 194.25 194.20 194.15 194.10

Central Wavelengt h (nm) 1540.95 1541.35 1541.75 1542.14 1542.54 1542.94 1543.33 1543.73 1544.13 1544.53

S/N 71 72 73 74 75 76 77 78 79 80

Sub-band Name C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1 C50_1

Central Frequenc y (THz) 192.55 192.50 192.45 192.40 192.35 192.30 192.25 192.20 192.15 192.10

Central Wavelengt h (nm) 1556.96 1557.36 1557.77 1558.17 1558.58 1558.98 1559.39 1559.79 1560.20 1560.61

TABLE 171 WAVELENGTH ALLOCATION (80 CHANNEL, L BAND)

S/N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Sub-band Name L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1

Central Frequenc y (THz) 190.90 190.85 190.80 190.75 190.70 190.65 190.60 190.55 190.50 190.45 190.40 190.35 190.30 190.25 190.20 190.15 190.10 190.05 190.00 189.95 189.90 189.85 189.80

Central Wavelengt h (nm) 1570.42 1570.83 1571.24 1571.65 1572.06 1572.48 1572.89 1573.30 1573.71 1574.13 1574.54 1574.95 1575.37 1575.78 1576.20 1576.61 1577.03 1577.44 1577.86 1578.27 1578.69 1579.10 1579.52

S/N 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

Sub-band Name L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1

Central Frequenc y (THz) 188.90 188.85 188.80 188.75 188.70 188.65 188.60 188.55 188.50 188.45 188.40 188.35 188.30 188.25 188.20 188.15 188.10 188.05 188.00 187.95 187.90 187.85 187.80

Central Wavelengt h (nm) 1587.04 1587.46 1587.88 1588.30 1588.73 1589.15 1589.57 1589.99 1590.41 1590.83 1591.26 1591.68 1592.10 1592.52 1592.95 1593.37 1593.79 1594.22 1594.64 1595.06 1595.49 1595.91 1596.34

Confidential and Proprietary Information of ZTE CORPORATION

329

ZXMP M900 (V2.20) Hardware Manual

S/N 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

Sub-band Name L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1

Central Frequenc y (THz) 189.75 189.70 189.65 189.60 189.55 189.50 189.45 189.40 189.35 189.30 189.25 189.20 189.15 189.10 189.05 189.00 188.95

Central Wavelengt h (nm) 1579.93 1580.35 1580.77 1581.18 1581.60 1582.02 1582.44 1582.85 1583.27 1583.69 1584.11 1584.53 1584.95 1585.36 1585.78 1586.20 1586.62

S/N 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80

Sub-band Name L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1 L50_1

Central Frequenc y (THz) 187.75 187.70 187.65 187.60 187.55 187.50 187.45 187.40 187.35 187.30 187.25 187.20 187.15 187.10 187.05 187.00 186.95

Central Wavelengt h (nm) 1596.76 1597.19 1597.62 1598.04 1598.47 1598.89 1599.32 1599.75 1600.17 1600.60 1601.03 1601.46 1601.88 1602.31 1602.74 1602.17 1603.57

176-Wavelength System
The wavelength allocation in a 176-channel system consisting of ZXWM M900 is described in Table 169.

330

Confidential and Proprietary Information of ZTE CORPORATION

Appendix B Configuration of Optical Supervision System


This appendix describes the definition, working principle and configuration of two kinds of supervision systems supported by the ZXWM M900: 2 M supervision system and 100 M supervision system.

2 M Supervision System
Definition
The 2 M supervision system employs 32 bytes (64 kbit/s) to carry ECC data, orderwire voice data, APS data and transparent user channel data of the system, forwarding and exchanging them in the format of PCM32 frame. The supervisory channel uses the 1510 nm wavelength. If the operating wavelengths of the system only involve those in L band, the 1625 nm wavelength will be used by the supervisory channel.

System Composition
The function of 2 M supervision system is mainly implemented by the NCP, OSC and OHP board together.

Note: In the 2 M supervision system, the NCPF board can replace the NCP board to complete the same function. In this case, the NET interface on the front panel of the NCPF board should be connected to the EMS.

The control information between boards is transferred via the backplane. Figure 172 illustrates the relationship between boards in the supervision systems.

Confidential and Proprietary Information of ZTE CORPORATION

331

ZXMP M900 (V2.20) Hardware Manual

FIGURE 172 2 M SUPERVISORY SYSTEM

Hardware Configurations
1. Installing boards Insert the NCP (or NCPF), OSC and the OHP board into corresponding slots in the OA subrack following the instruction in Table 7. These three boards are mandatory for a 2 M supervision system. 2. Accessing to the EMS The NCP or NCPF board implements the communication between the NE and the EMS through the interface Qx. For the NCP board, the Qx interface is the J9 interface in the common interface area of the OA subrack. For the NCPF board, the Qx interface is the NET interface on its front panel. If the NE communicates with the EMS directly, connect the network interface of the NE to that of the NM computer with a crossover network cable. If the NE communicates with the EMS through a HUB, connect both the network interface of the NE and that of the NM computer to the HUB with straight network cables, as shown in Figure 172. 3. Connecting optical fibers Connect optical fibers according to the actual networking and the information forwarding direction to transfer the supervision information between NEs.

332

Confidential and Proprietary Information of ZTE CORPORATION

Appendix B Configuration of Optical Supervision System

Connect the OSC board to the optical board of the main optical channel (OA or OBM) with optical fibers following the instruction in the section OSC Board.

Note: Each optical interface pair on the OSC board implements the recieving and sending of the supervision information for one site.

Connect optical boards of the main optical channel with each other. Refer to the instruction in the section OA Board for the connection of OA boards. Refer to the instruction in the section OBM Board for the connection of OBM boards.

Optional Hardware Configurations


The following introduces optional configurations of a 2 M supervision system. You can carry out corresponding configurations for the system according to the actual requirements. Adding a standby route The standby route is the Ethernet route connecting NCP/NCPF boards of all the NEs to the NM computer. When the optical supervisory channel fails, the standby route can guarantee the forwarding and exchanging of the supervision information. When the NCP board is used, connect both the J9 interface of the OA subrack and the network interface of the standby route to the HUB, as shown in Figure 172. When the NCPF board is used, connect both the NET interface on the NCPF board and the network interface of the standby route to the HUB. Managing the APS bus of multiple racks In a 2 M supervision system, additional APSF boards are needed when multiple racks have been equipped in the ZXWM M900 and so the APS bus should be managed. The APSF board is used to transfer the APS bus information between the master and the slave racks and implement the APR function in multiple directions. Transferring clock information in the TMUX subrack If the ZXWM M900 in a 2 M supervision system implements the clock function through the CA board in the TMUX subrack, an additional APSF board is needed to transfer the clock information.

Note: The APSF board should be installed in the slot 9 of the OA subrack in the master rack. Please refer to Table 8 for detailed information about the slot arrangement of the OA subrack.

Confidential and Proprietary Information of ZTE CORPORATION

333

ZXMP M900 (V2.20) Hardware Manual

EMS Software Configurations


The ZXWM M900 is managed by the ZXONM E300 network management software. The following introduces the common configuration of a 2 M supervision system in the ZXONM E300. Creating NEs in the 2 M supervision system In the client operation window of ZXONM E300, click the menu item Device Config > Create NE to create each NE in the supervision system according to the requirements listed in Table 172.
TABLE 172 REQUIREMENTS ON THE CREATION OF NES IN A 2 M SUPERVISION SYSTEM

Item System Type Device Type IP Address Subnet Mask

Requirement ZXWM M900 ZXWM M900 The IP address of the NE should be unique in the whole network. It is recommended to set 18 as the last section of the IP address. The default setting is 255.255.255.0. It can be changed according to actual requirements. There is no special requirement for other items. All the configuration should observe the configuring principle of the EMS and be consistent with the actual setting of the NE.

Others

4. Installing boards Double click the icon of the newly-created NE in the client operation window to enter the Card Management dialog box. Install the NCP, OHP, OSC and other service boards according to the actual board configuration. 5. Establishing optical connections between NEs Select the NEs to be connected in the client operation window, and then click the menu item Device Config > Common Management > Link Management to enter the Link dialog box. Establish bidirectional optical connections between main optical channel boards of each NE, such as OA boards. 6. Other configurations If the orderwire function is needed, set the orderwire phone number for each NE. If it is necessary to deal with the transparent user channel data, configure the user channel. For more configuration operations in detail, please refer to related manuals of the ZXONM E300.

334

Confidential and Proprietary Information of ZTE CORPORATION

Appendix B Configuration of Optical Supervision System

100 M Supervision System


Definition and Features
The 100 M supervision system adopts the 10/100 M Ethernet technology to encapsulate ECC data, orderwire voice data, APS data and transparent user channel data in IP data packets. All these data are transferred and exchanged in the format of Ethernet data frame. The supervisory channel uses the 1510 nm wavelength. If the operating wavelengths of the system only involve those in L band, the 1625 nm wavelength will be used by the supervisory channel. The 100 M supervision system shares the following features: Supporting the supervision system at the rate of 10 Mbit/s and 100 Mbit/s A 10 M supervision system is suitable for the long-distance transmission complying with Ethenet protocols. A 100 M supervision system is suitable for the short-distance transmission complying with Ethenet protocols. If the span is too large, which may cause too much line loss, we can implement the in-band supervision by accessing the 100 M supervision information to OTU boards. The precondition is that the OTU boards support the accessing of continuous-rate traffic. Compying with the OSPF protocol and supporting dynamic routes. When the network topology changes, it will collect and regenerate the route table automatically to keep the supervison channel unobstructed. Performing various protection and control functions, such as APS MS and channel protection, APR control and clock management Adopting the VoIP technology to improve the orderwire communication capability and expandability Providing the transparent user channel based on RS232/RS422 interfaces, and supporting the communication between Ethernet interfaces in the whole network Supporting QoS guarantee by updating board software, which ensures that IP packets with the higher priority, such as APS and voice data packets, can be forwarded first. Supporting large-scale networking, while just occupying rather few IP addresses

Confidential and Proprietary Information of ZTE CORPORATION

335

ZXMP M900 (V2.20) Hardware Manual

System Composition
The function of 100 M supervision system is mainly implemented by the NCPF, OSCF, APSF and OHPF board together. Figure 173 illustrates the basic structure of a 100 M supervision system.
FIGURE 173 100 M SUPERVISORY SYSTEM

In the figure above, the number 1 6 indicates six electrical Ethernet interfaces on the OSCF board respectively (port 1 port 6); while the number 7 and 8 indicates two optical interfaces respectively on the OSCF board (IN1/OUT1 and IN2/OUT2). Due to the compliance with the OSPF protocol, the NCPF, APSF, OHPF, slave OSCF, the standby route and the NM computer can be connected to any one of port 1 port 6. There is no fixed relationship between the ports and boards. More than four optical supervision directions can be implemented by equipping the OA subrack with more than two OSCF boards, among which one OSCF board must be inserted into the slot 7. In this way, it is unnecessary to configure several racks.

336

Confidential and Proprietary Information of ZTE CORPORATION

Appendix B Configuration of Optical Supervision System

Hardware Configurations
Note: This section only introduces the configuration of a 100 M supervision system for your reference. The configuration of a 10 M supervision system is similar to that of the 100 M supervision system.

1. Installing boards For a 100 M supervision system, the NCPF, OSCF, APSF and OHPF board must be installed in the OA subrack following the instruction in Table 9.

Note: If only two or less optical supervision directions are needed, insert one OSCF board into the slot 7 of the OA subrack. If three or more optical supervision directions are needed, insert more OSCF boards. One of these OSCF boards should be inserted into the slot 7 of the OA subrack. Other OSCF boards can be inserted into other unused slots of the OA subrack without restriction.

2. Connecting network cables In the 100 M supervision system, the control information between boards is transferred via Ethernet interfaces on the front panel of the boards. Connect the system boards, the standby route and the NM computer to any one of the port 1 port 6 on the OSCF board. i. The electrical Ethernet interfaces on the OSCF board have the automatic crossover function. Therefore, they can be connected to the boards or other devices with either crossover network cables or straight-through network cables.

ii. If a standby route is needed, connect it to one electrical Ethernet interface on the OSCF board. iii. Each NCPF board can manage four racks. If there are more than four racks, additional NCPF boards are needed. In this case, connect each NCPF board to the OSCF board through a HUB. iv. Each APSF board can support the transfer of the protection and switching information among four racks. If there are more than four racks, additional APSF boards are needed. In this case, connect each APSF board to the OSCF board through a HUB. 3. Connecting optical fibers Connect optical fibers according to the actual networking and the forwarding direction to transfer the supervision information between NEs. Connect the OSCF board to optical boards of the main optical channel (OA or OBM) with optical fibers following the instruction in the section OSC Board.

Confidential and Proprietary Information of ZTE CORPORATION

337

ZXMP M900 (V2.20) Hardware Manual

Note: Each optical interface pair on the OSCF board implements the recieving and sending of the supervision information for one site.

EMS Software Configurations


Note: Only the ZXONM E300 with the version V3.16R2 or above supports the configuration of the 100 M supervision system consisting of ZXWM M900.

The following introduces the configuration steps of a 100 M supervision system in the ZXONM E300. 1. Creating NEs in the 100 M supervision system In the client operation window of ZXONM E300, click the menu item Device Config > Create NE to create each NE in the supervision system according to the requirements listed in Table 173.
TABLE 173 REQUIREMENTS ON THE CREATION OF NES IN A 100 M SUPERVISION SYSTEM

Item System Type Device Type IP Address

Requirement ZXWM M900 (100M) ZXWM M900 (100M) The IP address of the NE should be unique in the whole network. The last section of the IP address should be n32+1, where n is an integer and n 7.

Subnet Mask

The default setting is 255.255.255.224. It can be changed according to actual requirements. There is no special requirement for other items. All the configuration should observe the configuring principle of the EMS and be consistent with the actual setting of the NE.

Others

2. Installing boards Double click the icon of the newly-created NE in the client operation window to enter the Card Management dialog box. Install the NCPF, APSF, OHPF, OSCF and other service boards according to the actual board configuration. 3. Establishing optical connections between NEs Select the NEs to be connected in the client operation window, and then click the menu item Device Config > Common Management > Link Management to enter the Link dialog box. Establish bidirectional optical connections between main optical channel boards of each NE, such as OA boards. 4. Setting the IP address of OSCF

338

Confidential and Proprietary Information of ZTE CORPORATION

Appendix B Configuration of Optical Supervision System

Select the NE in the client operation window, and then click the menu item Device Config > 100M Route Management > Card IP Configure. Set the IP address in the popped up dialog box based on the following principles. Electric Port 1-6 The Electric Port 1-6 in the Address SN column correspond to six optical interfaces on the OSCF board respectively. These six optical interfaces share the same IP address together, which are allocated by the EMS automatically according to the IP address of the NE. Optical Port 7/Optical Port 8 The Optical Port 7 and Optical Port 8 in the Address SN column correspond to the optical interface IN1/OUT1 and IN2/OUT2 respectively, which are the communication interfaces between the OSCF boards of two adjacent NEs. Their IP address should be set according to the optical connection relationship between NEs. Table 174 describes the configuration principles of them.
TABLE 174 CONFIGURATION PRINCIPLE OF IP ADDRESS OF OPTICAL INTERFACES ON OSCF BOARD

Item

Configuration Principle


IP Address

It can not conflict with other IP addresses in the network. If two OSCF boards are connected to each other with optical fibers, the IP addresses of corresponding optical interfaces should be set in the same network section. If there is no optical connection between two OSCF boards, the IP addresses of their optical interfaces can not be set in the same network section. For example, the IP address of the optical interface 7 and that of the optical interface 8 on the same OSCF board can not be set in the same network section.

Subnet Mask

The default setting is 255.255.255.0. It can be changed according to actual requirements. If the optical interface has not been enabled, set 0.0.0.0 as the subnet mask. The default value is 0. It is recommended to adopt the default value when the quantity of NEs is less than 200.

Area ID

Checkpoint: To enable the IP address, you must reset the OSCF board through hardware or NM software after configuring its IP address.

5. Configuring the multicast group route If the function of orderwire or MS protection is needed in the supervision system, you should calculate the route of corresponding multicast group first in the EMS.

Checkpoint: Only after the orderwire or MS protecion has been configured correctly, can the system generate corresponding multicast group automatically. For the

Confidential and Proprietary Information of ZTE CORPORATION

339

ZXMP M900 (V2.20) Hardware Manual

configuration operations in detail, please refer to related manuals of the ZXONM E300.

The 100 M supervision system issues the orderwire and protection switching commands to related NEs in the multicast group following the multicast mode. Each supervision system involves three multicast groups, one orderwire group and two protection groups. The system generates the IP addresses of these multicast groups automatically, which are in the multicast network section (224.*.*.*). Configure the multicast group route by the following steps: i. Select the NE in the client operation window, and then click the menu Device Config > 100M Route Management > NE Multicast Group Route to pop up the configuration dialog box;

ii. Select the group in the Select Group pull-down list, and then click the Calculation and Apply button to load the route information to the board.

340

Confidential and Proprietary Information of ZTE CORPORATION

Appendix

Configuration of Integrated Wavelength Supervision Subsystem


This appendix introduces the basic concepts, hardware continuation and software configuration of the integrated wavelength supervision subsystem.

Overview
Stable wavelengths reflect that their corresponding frequencies do not drift. The impact of frequency drift on the system is relatively small in a DWDM system with the channel spacing at 100 GHz. However, in a system with higher single channel rate and smaller channel spacing (for example, in an 80-channel system with the spacing at 50 GHz), the frequency drift will impact on the system stability directly. The ZXWM M900 supports two wavelength stabilization modes suitable for systems with different channel spacings. For systems with the spacing at 100 GHz, the automatic power control, and the temperature and internal wavelength feedback is used to stabilize wavelengths via optical transponder boards. For systems with the spacing at 50 GHz, the internal and external wavelength feedback is adopted to improve the stability and precision of wavelength control. Internal wavelength feedback: Its function is same as that of system with the spacing at 100 GHz, which is performed by optical transponder boards. External wavelength feedback: This function is implemented through integrated inspection and sequence adjustment. This mode is adopted in integrated wavelength supervision subsystems.

The following sections describe the configuration of integrated supervision subsystem in detail.

Confidential and Proprietary Information of ZTE CORPORATION

341

ZXMP M900 (V2.20) Hardware Manual

Subsystem Composition
An integrated wavelength supervision subsystem is composed of OWM board, boards of multiplexing type, optical transponder boards, NCP or NCPF board and the EMS ZXONM E300. Figure 174 illustrates the functional block diagram of the subsystem.
FIGURE 174 INTEGRATED WAVELENGTH SUPERVISION SUBSYSTEM

OWM ZXONM E300


Output from MON interface

NCP/NCPF

Multiplexing board O T U 1 O T U 2
...

O T U n

Output of OTU

Wavelength control information

The function of each board in the subsystem is described as follows. OWM board Detecting the wavelength deviation of each channel in the aggregate optical signal, and informing the NCP/NCPF board if the deviation of any wavelength is out of limit. Receiving commands relative to wavelength adjustment from the ZXONM E300, and then feeding the adjusting result back to the ZXONM E300.

NCP/NCPF board It receives the wavelength adjustment commands from the OWM board, and forwards the commands to corresponding optical transponder boards until the wavelength deviation meets the requirement.

Multiplexing board It outputs the aggregate optical signal, which will be inspected, to the OWM board. In actual connections, the aggregate optical signal is output from the MON interface on the board of amplification type.

Optical transponder board It receives the wavelength adjustment command from the NCP/NCPF board, and then sends the adjusting result back to the NCP/NCPF board. It can be the board of OTU series, SRM41, SRM42 or GEMF board. The channel spacing of the board should be 50 GHz.

342

Confidential and Proprietary Information of ZTE CORPORATION

Appendix C Configuration of Integrated Wavelength Supervision Subsystem

ZXONM E300 Users can set related parameters, enables or disables the wavelength adjustment function through the ZXONM E300, which gives the adjustment command to the OWM board.

Hardware Configurations
In terms of equipment type in DWDM systems, this section introduces the hardware configuration of OTM and OADM equipment for an integrated wavelength supervision subsystem.

Configurations of OTM
Taking an 80-channel DWDM system as example, Figure 175 illustrates the position of OWM board configured in OTM equipment.
FIGURE 175 POSITION OF OWM BOARD IN OTM EQUIPMENT

As shown in Figure 175, the OWM board is equipped at the transmitting end, with the IN interface connected to the MON interface on the OBA board. The wavelengths of all the OTUs monitored by the OWM board should be in either C band or L band. For a DWDM system involving wavelengths in C+L band, two OWM boards should be equipped, one for wavelengths in C band and the other for those in L band.

Confidential and Proprietary Information of ZTE CORPORATION

343

ZXMP M900 (V2.20) Hardware Manual

The OWM board and all the OTUs monitored by it must be managed by the same NCP/NCPF board. In other words, the OWM board and all the monitored OTU boards should be installed in the cabinet(s) managed by the same NCP/NCPF board. For back-to-back OTM equipment, boards of two optical directions should be installed in two different cabinets. In each cabinet, mount the NCP/NCPF board and OWM board of one direction.

Configurations of OADM
Taking a bidirectional OADM site as example, Figure 176 illustrates the position of OWM board configured in OADM equipment.
FIGURE 176 POSITION OF OWM BOARD IN O ADM EQUIPM ENT
OWM OPA OAD
MON interface

OBA

OSC OBA
MON interface

OTU

OTU OPA OAD

OSC

OWM

In OADM equipment, the OWM board only monitors the added wavelengths instead of those passing through. The IN interface on the OWM board is connected to the MON interface on the OBA board so as to monitor the wavelengths added at the OAD board. An OWM board can only monitor wavelengths in the same band. For a DWDM system involving wavelengths in C+L band, two OWM boards should be equipped, one for wavelengths in C band and the other for those in L band. One OWM board should be equipped in each line direction of OADM equipment, so that the EMS can filter the supervision wavelength according to the direction information. The OWM board and all the OTUs monitored by it must be managed by the same NCP/NCPF board. In other words, the OWM board and all the monitored OTU boards should be installed in the cabinet(s) managed by the same NCP/NCPF board.

344

Confidential and Proprietary Information of ZTE CORPORATION

Appendix C Configuration of Integrated Wavelength Supervision Subsystem

EMS Software Configurations


Note: Only the ZXONM E300 with the version V3.16R2 or above supports the software configuration of integrated wavelength supervision subsystems.

The EMS software configurations for an integrated wavelength supervision subsystem include the setting of supervision wavelength, and the commanding of inspection and adjustment etc. The detailed configurations are described in Table 175 as follows.
TABLE 175 EMS SOFTWARE CONFIGURATIONS OF INTEGRATED W AVELENGTH SUPERVISION SUBSYSTEM

1. Automatic Wavelength Adjustment Configuration Purpose To set the inspection port of the OWM board, enable or disable the inspection and adjustment of the wavelengths for the boards monitored by the OWM board. Maintenance > Power Management > OWM Set Wavelength Auto Adjustment Board: Select an OWM board from the pull-down list box to display the information about all the OTU boards which can be monitored by this OWM board in the dialog box. In Port: Select the inspection port, Port1 or Port2, from corresponding pull-down list box. The default option is Port1. The Port2 is usually used for the automatic calibration function. Whether Auto Inspect: Select from the pull-down list box to enable or disable the automatic wavelength inspection function for each board one by one. You can also tick the Whole Inspect check box to enable the function for all boards at one time. Enable Adjust: Select or unselect this check box to enable or disable the automatic adjustment function for all boards whose automatic inspection function has been enabled. After selecting the OWM board, the EMS will filter out the boards with the wavelength locking function and those without the wavelength adjustment function. After the supervision command has been given, the OWM board will report the alarm when the wavelength drift of the inspected OTU is out of limit. After the adjustment command has been given, the OTU adjusts the wavelength automatically when the wavelength drift of the inspected OTU is out of limit.

Menu Item

Configuration

Result

Confidential and Proprietary Information of ZTE CORPORATION

345

ZXMP M900 (V2.20) Hardware Manual

2. Automatic Calibration Configuration Optical components age after longtime running, due to which the wavelength inspection error can not meet the requirement of index. In order to guarantee the system precision, the automatic calibration function is provided. Offering a standard wavelength to the OWM board, the EMS gives an automatic calibration command. Then the OWM board calculates the deviation between the measured wavelength and the standard one. When the OWM inspect the operating wavelength, it will deduct the deviation from the measured value to ensure the precision. Maintenance > Power Management > OWM Calibrate Configuration Board: Select an OWM board from the pull-down list box. Port: Select the inspection port of the OWM board. The default option is Port2. Frequency (THz): Select the calibrating wavelength (unit: THz).

Purpose

Menu Item


Result

Click the Apply button to give the calibration command, and then the OWM board will return the calibration result.

346

Confidential and Proprietary Information of ZTE CORPORATION

Appendix

Configuration of OMS Layer Power Management Subsystem


This appendix introduces the basic concepts and configurations of the Optical Multiplex Section (OMS) layer power management.

Introduction to Automatic Power Management


The ZXWM M900 provides the automatic power management function by adopting the optical power equalization technology for the OMS layer and the Optical Channel (OCH) layer Power management of OCH layer The purpose of OCH power management is to establish and hold the power equalization of the optical channel. It includes the fixed power compensation and the dynamic channel power management. Fixed power compensation: It uses the LAC board with Gain Flattening Filter (GFF) to ensure the flatness of the gain spectrum. Dynamic channel power management: It uses the VMUX board and adopts the gain spectrum slope adjustment technology, dynamic gain equalization technology, and the optical performance supervision technology to solve the problem of power disequilibrium between different channels, which is caused by non-linearity effect and unflatness accumulation of multi-stage OAs in ultra long-haul and large-capacity systems.

Power management of OMS layer The purpose of OMS power management is to establish and keep the optimal status of OMS aggregate power. The following sections introduce the concept and implementation of OMS power management.

Confidential and Proprietary Information of ZTE CORPORATION

347

ZXMP M900 (V2.20) Hardware Manual

Power Management of OMS Layer


Working principle The power management of OMS layer is based on each power management domain. A power management domain is the transmission section between two OTMs, that is, the OMS, as shown in Figure 177.
FIGURE 177 POWER M AN AGEMENT DOM AIN
OMS
NODE1 NODE2 NODE3 NODEn-1 NODEn

OTM A1

OLA A2 G1 OTS OTS

OLA A3 G2

OLA G3

OLA An Gn-1

OTM Gn

OMS: Optical Multiplex Section OTS: Optical Transmission Section Ax: Line attenuation before node x, x=1, 2, 3, , n Gx: Gain of node x, x=1, 2, 3, , n-1, n

The power of the OMS layer is optimized according to the preset parameters of the system and the current power of each OTS. Ideally, the difference between gain attenuation meets the following formula.

Gi Ai = 0
i =1 i =1

In actual optical path, the optimization begins once the attenuation difference meets the fault condition of OMS power management. When the difference reaches the value in a specified range, the optimization ends. Finally, it ensures that all the attenuation difference in the same OMS approaches to zero.

348

Confidential and Proprietary Information of ZTE CORPORATION

Appendix D Configuration of OMS Layer Power Management Subsystem

Hardware and Software Support The power management function of OMS layer needs related hardware and software support, as listed in Table 176.

TABLE 176 HARDW ARE/SOFTWARE NEEDED IN POWER M ANAGEMENT OF OMS LAYER

Hardware/Software LAC Hardware (Board) OA HOBA DRA Software (EMS)

Function It determines the attenuation amount of LAC according to the optimization algorithm when the line attenuation changes. They provide the gain adjustment function through determining the gain according to the optimization algorithm when the line attenuation changes. It supports the setting of related parameters of power management, the query of current power status, the commanding of power management. However, only the ZXONM E300 of V3.16R2 or above supports these operations.

ZXONM E300

Division of Power Management Domain The OMS layer power management requires that the performance of each power management domain is independent, such as the power and SNR. The division of power management domain is different for systems with different channels, as described below. Systems with channels less than 80 In such systems, every OTM and OADM, OADM and OADM, and every OTM and OTM constructs their respective power management domain. Taking an 80-channel system as example, Figure 178 illustrates an OMS power management domain between two OTMs. In the figure, all the OLAs between OTM1 and OTM2 are omitted.

FIGURE 178 DIVISION OF POWER M AN AGEMENT DOM AIN (80-CHANNEL SYSTEM)


OTM1 OTU . . OMU (C) OCI (C) OMU (C+) O S C O S C OBA OPA DCM OBA VGSC OCI (C) ODU (C+) ODU (C)

OTM2 OTU . .

OTU . .

OTU . .

DRA

OPM

OMS

Confidential and Proprietary Information of ZTE CORPORATION

349

ZXMP M900 (V2.20) Hardware Manual

The OA, LAC, HOBA and DRA boards in the OMS can all be taken as the monitoring boards and the implementing boards of this power management domain. Systems with channels more than 80 When a system has more than 80 operating wavelengths covering C band and L band, the power management domain should be divided into the domain of C band and that of L band, as illustrated in Figure 179. All the OLAs between OTM1 and OTM2 are omitted in the figure.
FIGURE 179 DIVISION OF POWER M AN AGEMENT DOM AIN (MORE THAN 80 CHANNELS)

OTM1 OTU . . OMU (C) OCI (C) OMU (C+) O S C OMU (L) OCI (L) OMU (L+) OMS (C Band)

OTM2 OTU OPM DCM VGSC OBA OCI (C) ODU (C+) ODU (C) . .

OTU . .

OBA

OPA

OTU . .

OTU . .

OBM C/L

OBM (C/L)

O S C ODU (L) DCM VGSC OBA OPM OCI (L) ODU (L+)

OTU . .

OTU . .

OBA

DRA OMS (L Band)

OPA

OTU . .

In the OMS (C Band), all the OA, LAC and HOBA boards processing optical signals in C band can be taken as the monitoring boards and the implementing boards of the C band power management domain. In the OMS (L Band), all the OA, LAC and HOBA boards processing optical signals in L band can be taken as the monitoring boards and the implementing boards of the L band power management domain.

Note: The DRA board amplifies both the optical signals in C band and those in L band, which makes the C band and L band can not be independent of each other. Therefore, in systems with channels more than 80, the DRA board can not be taken as the implementing board in the power management domain.

Working Conditions of OMS Power Optimization When the ZXONM E300 detects that the gain attenuation difference meets the start/end condition of power optimization, it will give the start/end command to corresponding boards. The OMS layer power management includes the following two modes:

350

Confidential and Proprietary Information of ZTE CORPORATION

Appendix D Configuration of OMS Layer Power Management Subsystem

OMS layer power optimization: The operator gets the adjustment value of each executor according to the automatic power optimization algorithm, determines whether to modify the value, and then gives the adjustment command to the board through the ZXONM E300. Automatic power management: The operator sets the optimization conditions first. The ZXONM E300 will send the adjustment value calculated through the optimization algorithm automatically to the board without the need of manual operation.

Table 177 describes the working conditions of the two optimization modes with default settings.
TABLE 177 WORKING CONDITIONS OF OMS LAYER POWER M AN AGEMENT

Working Condition

Default Threshold Fault OTS attenuation mismatch OMS attenuation mismatch OMS normalized optical power difference between the beginning and the end OA OTS attenuation mismatch OMS attenuation mismatch OMS normalized optical power difference between the beginning and the end OA No input light No light output OMS Power Optimization 2 dB Automatic Power Management 2 dB Remark It can be changed in the ZXONM E300. It can be changed in the ZXONM E300.

3 dB

3dB

Optimization starting

2 dB

2 dB

It can be changed in the ZXONM E300.

1 dB

1 dB

1 dB

1 dB

Optimization ending

1 dB

1 dB

Optimization failure

It can be changed in the ZXONM E300.

OTS attenuation mismatch

3 dB

Confidential and Proprietary Information of ZTE CORPORATION

351

ZXMP M900 (V2.20) Hardware Manual

Working Condition

Default Threshold Fault OMS attenuation mismatch OMS normalized optical power difference between the beginning and the end OA OMS Power Optimization 4 dB Automatic Power Management Remark It can be changed in the ZXONM E300.

3 dB

It can be changed in the ZXONM E300.

EMS Configurations
Note: Only the ZXONM E300 with the version V3.19R1 or above supports the configuration of the OMS layer power management function.

This section introduces the creation and configuration of the OMS power management domain.

Checkpoint: Before the configuration, you should check the following items first. All necessary boards have been installed correctly; The optical connections are correct; The EMS communicates with the NE well.

Creating an OMS Power Management Subsystem


The following describes the steps to create an OMS power management subsystem. 1. Establish the optical connection of main optical channel between NEs i. In the Main View of the client operation window, select the source NE and the destination NE;

ii. Click the menu item Device Config > Common Management > Link Management to establish the optical connections between boards for the main optical channel according to the actual networking requirements.

352

Confidential and Proprietary Information of ZTE CORPORATION

Appendix D Configuration of OMS Layer Power Management Subsystem

2. Establish the optical connections between boards in each NE i. In the Main View of the client operation window, select the NE; ii. Click the menu item Device Config > Common Management > Inner Connection of NEs to pop up the configuration dialog box; iii. Select a source board and then click the Config button; iv. In the pop-up dialog box, select the destination board and establish the optical connection between ports of the boards according to the traffic flow direction. 3. Enable the SNMS resource The OMS layer power management subsystem is a kind of Subnet Management System (SNMS). Its functions can only be implemented in the WDM SNMS View of the client operation window. i. Open the WDM SNMS View in the client operation window first, and then click the menu item System > SNMS Start/Stop to pop up the SNMS Start Config dialog box.

ii. Click the Start button to enable the SNMS resource. 4. Configure the SNMS resource Search the information about OTS/OMS already created in the SNMS and save the searching result.

Note: Only when some connections in NEs or between NEs change, should the SNMS resource be reconfigured. If no connection changes, and the SNMS resource has been configured, this step can be skipped.

i.

In the WDM SNMS View of the client operation window, click the menu item Config > SNMS Resource Config to pop up the SNMS Config dialog box.

ii. Click the Auto Compute button to refresh the information about OTS/OMS in the EMS database. iii. Select All Records in the Compute Result dialog box and then click the Apply button. 5. Configure the power management domain

Note: If the power management domain adopts the default parameters, this stepcan be skipped.

i.

In the WDM SNMS View, click the menu item Power Adjust > Power Management Domain Config to pop up the PNMS Config dialog box;

Confidential and Proprietary Information of ZTE CORPORATION

353

ZXMP M900 (V2.20) Hardware Manual

ii. Select the PNMS Layer to configure the power management layer, and then select the OMS layer (namely, power management domain) and the PNMS layer (namely, OTS) from corresponding pull-down list box; iii. Click the Config Monitor button to select the monitor board in the pop-up dialog box; iv. Click the Config Executer button to select the executer board in the pop-up dialog box; v. In the Parameter Config combo box, set the SOTS attenuation limit, OA supplemental gain, OMS compute powers K value and the OMS mismatch power; vi. Select the OMS in the SNMS TYPE combo box and then select the OMS layer (namely, power management domain) to be configured. vii. In the OMS configuration, set the corresponding parameters.

Configuring the OMS Power Management Subsystem


After the OMS power management domain has been created successfully, configure the management domain in the ZXONM E300 to implement the OMS layer power optimization, automatic power management and the query of optimization logs. Table 178 describes the configuration operations in detail.
TABLE 178 CONFIGURATIONS OF OMS POWER M AN AGEMENT SUBSYSTEM

1. Configure OMS Layer Power Optimization Purpose Menu Item To query current performance and optimization result of the OMS power management domain, modify the adjustment value manually and issue the command WDM SNMS View: Power Adjust > OMS Optimize Query current performance of the OMS power management domain: In the OMS optimization dialog box, select the PNMS, click the Query performance button, and then the current power, modified value and attenuation of each OTS will be shown in Monitor state, Executer current value and SOTS attenuation list boxes. Query the power optimization result: In the OMS optimization dialog box, select the PNMS, click the Power optimization button to display the attenuation sum of OMS and each OTS after the optimization in the pop-up dialog box. The query result is shown in the Monitor state, Executer current value and SOTS attenuation list boxes. Moreover, the Executer modified value list box displays the modified value of current executor calculated by using the optimization algorithm. Adjust the modified value of the executer manually: Click the Power optimization button to query the optimization result of the PNMS first, modify the value in the Executer modified value list box and then click the Apply button.

Configuration

354

Confidential and Proprietary Information of ZTE CORPORATION

Appendix D Configuration of OMS Layer Power Management Subsystem

Result

This function is only effective for NEs in normal communication with the EMS. In the SOTS attenuation list box, the yellow background of a queried item indicates that the attenuation sum of this OTS exceeds the matching threshold. In the Executer modified value list box, the yellow background of a queried item indicates that the executer board should be adjusted according to the optimization algorithm. At the same time, the recommended value is displayed in the Modified value column, which can be changed.

2. Configure Automatic Power Management Purpose Menu Item To set the stop condition of automatic power management, configure the time interval, enable or disable the automatic power management WDM SNMS View: Power Adjust > Auto Power Optimize Management 1. Set the time interval of the automatic power management; 2. Set the stop condition of automatic power management. The optimization will be stopped once any condition is met. It is recommended to set the stop condition as follows. One OTS gain decrease exceeds 3 dB Configuration OMS gain decrease exceeds OMS OA power margin exceeds 4 dB 3 dB

3. Click the Query button to report information about all the PNMSs managed by the server (manager); 4. Configure the power management region. The Power Region Config list box displays all the PNMSs which have been configured. 5. Enable or disable the PNMS. By default, the automatic power management function is disabled. Result This function is only effective for NEs in normal communication with the EMS. If the automatic power management is enabled, the optimization result can not be changed manually during the optimization.

3. Query Power Management Log Purpose Menu Item To query the records of power optimization and automatic power management WDM SNMS View: Power Adjust > Power Optimize Log Query Set the query condition (time period) in the dialog box, and click the Query button to display the optimization log. Or click the Advance button to set the filter condition (Succeed or Failed), and select the PNMS to be queried. In the log, the Operation Type column displays the type of the OMS power optimization, manually or automatically.

Configuration

Result

Confidential and Proprietary Information of ZTE CORPORATION

355

ZXMP M900 (V2.20) Hardware Manual

356

Confidential and Proprietary Information of ZTE CORPORATION

Abbreviations
Abbreviation AFR AFEC AGENT AIS APO APR APS APSD APSF ASE AWG BER BLSR BSHR CDR CMI CODEC CPU CRC DBMS DCC DCF DCG DCN DCM DDI DGFF DSF DGD DTMF Full Name Absolute Frequency Reference Advanced FEC Agent Alarm Indication Signal Auto Performance Optimization Automatic Power Reduction Automatic Protection Switching Automatic Power ShutDown Automatic Protection Switching for FastEthernet Amplified Spontaneous Emission Array Waveguide Grating Bit Error Ratio Bidirectional Line Switching Ring Bidirectional Self-Healing Ring Clock and Data Recovery Code Mark Inversion Code and Decode Central Processing Unit Cyclic Redundancy Check Database Management System Data Communications Channel Dispersion Compensation Fiber Dispersion Compensation Grating Data Communications Network Dispersion Compensation Module Double Defect Indication Dynamic Gain Flattening Filter Dispersion Shifted Fiber Differential Group Delay Dual-Tone Multi-Frequency

Confidential and Proprietary Information of ZTE CORPORATION

357

ZXMP M900 (V2.20) Hardware Manual

Abbreviation DWDM DVB DXC EAM ECC EDFA EFEC ERZ ES ESCON EX FC FDDI FDI FEC FICON FPDC FWM GE GEF GFF GUI HDTV Interleaver IP IWF LD LOF LOS MANAGER MCU MBOTU MQW MSP MST NE NNI

Full Name Dense Wavelength Division Multiplexing Digital Video Broadcasting Digital Cross-connect Electrical Absorption Modulation Embedded Control Channel Erbium Doped Fiber Amplifier Enhanced FEC Electrical Return to Zero Errored Second Enterprise System Connection Extinction Ratio Fiber Channel Fiber Distributed Data Interface Forward Defection Indication Forward Error Correction Fiber Connection Fiber Passive Dispersion Compensator Four Wave Mixing Gigabits Ethernet Gain Equalizing Filter Gain Flattening Filter Graphical User Interfaces High Definition TV Internet Protocol Integrated Wavelength Feedback Laser Diode Loss of Frame Loss of Signal Manager Management and Control Unit OTU Main Board Multiple Quantum Well Multiplex Section Protection Multiplex Section Termination Network Element Network Node Interface

358

Confidential and Proprietary Information of ZTE CORPORATION

Abbreviations

Abbreviation NMCC NRZ NT NZDSF OADM OBA OCH ODF ODU OGMD OLA OLT ONU OP OPA OPM OSC OSNR OTM OTN OXC PDC PMD PDL RAC RZ SAN SDH SDM SEF SES SFP SLIC SMCC SMT SNMP STM

Full Name Network Manage Control Center Non Return to Zero Network Termination Non-Zero Dispersion Shifted Fiber Optical Add/Drop Multiplexer Optical Booster Amplifier Optical Channel Optical fiber Distribution Frame Optical channel Data Unit Optical Group Mux/DeMux Board Optical Line Amplifier Optical Line Termination Optical Network Unit Optical Protection Unit Optical PreAmplifier Optical Performance Monitor Optical Supervision Channel Optical Signal-Noise Ratio Optical Terminal Optical Transport Network Optical Cross-connect Passive Dispersion Compensator Polarization Mode Dispersion Polarization Dependent Loss Receiver Adaptive Control Return to Zero Storage Area Network Synchronous Digital Hierarchy Supervisory Division Multiplexing Board Severely Errored Frame Severely Errored Second Small Form Factor Pluggable Subscriber Line Interface Circuit Sub-network Management Control Center Surface Mount Simple Network Management Protocol Synchronous Transfer Mode

Confidential and Proprietary Information of ZTE CORPORATION

359

ZXMP M900 (V2.20) Hardware Manual

Abbreviation SWE TCP TFF TMN TTI UAS VCF VOA WDM

Full Name Electrical Switching Board Transmission Control Protocol Thin Film Filter Telecommunications Management Network Trail Trace Identifier Unavailable Second Voltage-Controlled Optical Filter Variable Optical Attenuator Wavelength Division Multiplexing

360

Confidential and Proprietary Information of ZTE CORPORATION

Figures
Figure 1 Outline and Dimensions of ZTE Cabinet (with Depth 300 mm) ............... 2 Figure 2 Basic Fittings in ZTE Cabinet............................................................. 3 Figure 3 Grounding Terminals in Cabinet ........................................................ 5 Figure 4 Components Position in Cabinet ....................................................... 8 Figure 5 Structure of OA Subrack .................................................................. 9 Figure 6 Outline of Dustproof Net .................................................................11 Figure 7 Left Fiber Cable Reel-in Box.............................................................11 Figure 8 Boards Arrangement in OA Subrack (for 2 M Supervisory System without APSF) ...............................................................................................12 Figure 9 Boards Arrangement in OA Subrack (for 2 M Supervisory System with APSF) ........................................................................................................13 Figure 10 Boards Arrangement in OA Subrack (for 100 M Supervisory System) ...14 Figure 11 Common Interface Area on Backplane of OA Subrack ........................15 Figure 12 Pins Order of DIP Switch (J10) .......................................................16 Figure 13 Pins of J1/J17 Power Socket ..........................................................19 Figure 14 DB9 Socket (male) .......................................................................19 Figure 15 DB9 Socket (female) ....................................................................20 Figure 16 Structure of OTU Subrack..............................................................22 Figure 17 Board Slots in OTU Subrack ...........................................................23 Figure 18 Common Interface Area on Backplane of OTU Subrack ......................24 Figure 19 Board Slots in TMUX Subrack .........................................................26 Figure 20 Common Interface Area on TMUX Backplane ....................................27 Figure 21 Structure of Orderwire Phone Bracket .............................................29 Figure 22 Structure of Independent Fan Unit ..................................................30 Figure 23 Maintenance of Independent Fan Unit .............................................31 Figure 24 Structure of Power Alarm Subrack ..................................................31 Figure 25 Structure of Power Distribution Subrack ..........................................32 Figure 26 Structure of Monitoring Plug-in Box.................................................34 Figure 27 Outline of ODF Plug-in Box ............................................................35 Figure 28 Inner Structure of ODF Plug-in Box .................................................35 Figure 29 Position and Number of Optical Connectors on ODF Board ..................35 Figure 30 Structure of DCM Plug-in Box.........................................................36 Figure 31 Structure of OTU Board.................................................................41 Figure 32 Structure of PBX Board .................................................................42 Figure 33 Structure of PWSB Board...............................................................43 Figure 34 Structure of FCB Board .................................................................44 Figure 35 Operating Principle of Terminal OTU Board.......................................46 Figure 36 Operating Principle of Regenerator OTU Board..................................46 Figure 37 Front Panel of OTU Board ..............................................................48 Figure 38 Operating Principle of Terminal OTUF Board .....................................53 Figure 39 Operating Principle of Regenerator OTUF Board ................................53 Figure 40 Front Panel of OTUF Board.............................................................55 Figure 41 Operating Principle of Single-Path Bidirectional OTU10G ....................61 Figure 42 Operating Principle of Single-channel Unidirectional OTU10G G ...........61 Figure 43 Front Panel of Single-Path Bidirectional OTU10G Board ......................62 Figure 44 Operating Principle of Single-Channel Bidirectional EOTU10G ............67 Figure 45 Operating Principle of Regenerator EOTU10G..................................68 Figure 46 Front Panel of Single-Channel Bidirectional EOTU10G Board .............70 Figure 47 Operating Principle of SRM41/SRM42 Board .....................................77 Figure 48 Front Panel of SRM41 Board ..........................................................79

Confidential and Proprietary Information of ZTE CORPORATION

361

ZXMP M900 (V2.20) Hardware Manual

Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure

49 Operating Principle of GEM2 Board ................................................87 50 Front Panel of GEM2 Board ..........................................................89 51 Operating Principle of GEMF Board..................................................94 52 Front Panel of GEMF Board ............................................................97 53 Operating Principle of GEM8 Board ..............................................103 54 Front Panel of GEM8 Board ........................................................104 55 Operating Principle of DSA Board ................................................112 56 Front Panel of DSA Board ..........................................................114 57 TM Working Mode of DSA Board .................................................117 58 OAD Working Mode of DSA Board ...............................................117 59 Operating Principle of DSAF Board ..............................................125 60 Front Panel of DSAF Board.........................................................128 61 Operating Principle of DSAE Board ..............................................137 62 Front Panel of DSAE Board.........................................................139 63 TM Working Mode of DSAE Board................................................141 64 OAD Working Mode of DSAE Board..............................................142 65 Operating Principle of SMU Board................................................147 66 Front Panel of SMU Board ..........................................................149 67 Operating Principle of OCI Board .................................................. 155 68 Front Panel of OCI Board.............................................................156 69 Optical Connections of OCI Boards in an 80/96-Channel System .......158 70 Optical Connections of OCI Boards in a 160/176-Channel System......159 71 Operating Principle of OBM Board .................................................160 72 Front Panel of OBM Board............................................................162 73 Optical Connections of OBM Boards...............................................164 74 Operating Principle of OMU Board .................................................166 75 Front Panel of OMU40 Board ........................................................168 76 Optical Connections of OMU Board (Wavelength Number n 40) ..... 170 77 Optical Connections of OMU Board (more than 48-channel) .............. 170 78 Operating Principle of VMUX Board ...............................................172 79 Front Panel of VMUX Board ..........................................................173 80 Optical Connections of VMUX Board ..............................................175 81 Operating Principle of ODU Board .................................................176 82 Front Panel of ODU Board............................................................178 83 Optical Connection of ODU Board (Wavelength Number n 40) ...... 180 84 Operating Principle of OAD Board (8 Wavelengths).......................... 181 85 Front Panel of OAD8 Board ..........................................................182 86 Optical Connections of OAD8 Board ..............................................184 87 Operating Principle of WBU/AD2 Board ........................................186 88 Operating Principle of WBU/DGE Board..........................................187 89 Front Panel of WBU Board..........................................................188 90 Optical Connections of WBU/AD2 Baord .......................................190 91 Operating Principle of WSUD/MA2 Board........................................193 92 Operating Principle of WSUD/E Board ............................................ 194 93 Operating Principle of WSUA/MD2 Board........................................195 94 Operating Principle of WSUA/E Board ............................................195 95 Front Panel of WSU Board..........................................................196 96 Optcial Connections of WSUD/MA2 Board.....................................198 97 Optical Connections of WSUD/MA2 Board (with WSUA/E Boards) .....199 98 Operating Principle of WBM Board ...............................................201 99 Front Panel of WBM Board .........................................................202 100 Optical Connections of WBM Board ............................................204 101 Operating Principle of SDM Board ............................................... 206 102 Front Panel of SDM Board ..........................................................207 103 Optical Connection of SDM Board................................................ 208 104 Operating Principle of EOLA Board ..............................................213 105 Operating Principle of EONA Board ..............................................214 106 Front Panel of EOBA Board.........................................................216 107 Front Panel of EOLAD Board .......................................................218 108 Front Panel of EOPAD Board.......................................................220 109 Front Panel of EONA Board ........................................................222

362

Confidential and Proprietary Information of ZTE CORPORATION

Figures

Figure 110 Typical Optical Connections of EOA Board................................... 224 Figure 111 Operating Principle of DRA Board (C Band)...................................227 Figure 112 Operating Principle of DRA Board (C+L Band) ............................... 228 Figure 113 Front Panel of DRA Board ..........................................................229 Figure 114 Operating Principle of LAC Board (LACG)...................................... 233 Figure 115 Front Panel of LAC Board ...........................................................234 Figure 116 the optical connection of LAC boards (1) ......................................235 Figure 117 the optical connection of LAC boards (2) ......................................236 Figure 118 Operating Principle of OWM Board...............................................237 Figure 119 Front Panel of OWM Board .........................................................238 Figure 120 Operating Principle of OPM Board................................................ 241 Figure 121 Front Panel of OPM Board ..........................................................242 Figure 122 The Position of MCPD Board in the System ................................... 244 Figure 123 Operating Principle of MCPD Board..............................................245 Figure 124 Front Panel of MCPD Board ........................................................246 Figure 125 Operating Principle of OP Board ..................................................248 Figure 126 Front Panel of OP Board ............................................................249 Figure 127 Optical Connections of OP Board (OTU 1+1 Protection, OTU Redundancy Mode in Chain Network).....................................................................251 Figure 128 Optical Connections of OP Board (OTU 1+1 Protection, OTU Redundancy Mode in Ring Network) ......................................................................252 Figure 129 Optical Connection of OP Board (OTU 1+1 Protection).................... 253 Figure 130 Optical Connection of OP Board (OA shared configuration mode) .....254 Figure 131 Optical Connection of OP Board (EOA redundancy configuration mode) ......................................................................................................254 Figure 132 Operating Principle of OPMS Board ............................................256 Figure 133 Front Panel of OPMS Board ......................................................257 Figure 134 Configuration for Multiplex Section Shared Protection................... 260 Figure 135 Operating Principle of OPCS Board ............................................261 Figure 136 Front Panel of OPCS Board .......................................................262 Figure 137 Configuration for Optica Channel Shared Protection ..................... 264 Figure 138 Operating Principle of OMCP Board..............................................265 Figure 139 Front Panel of OMCP Board ........................................................267 Figure 140 Optical Connection of OMCP Board (Bidirectional 1:8 Protection) .....269 Figure 141 Optical Connection of OMCP Board (Bidirectional 1:16 Protection)....270 Figure 142 Operating Principle of NCP Board ................................................ 272 Figure 143 Front Panel of NCP Board...........................................................273 Figure 144 Operating Principle of OSC Board................................................276 Figure 145 Front Panel of OSC Board ..........................................................277 Figure 146 Optical Connection of OSC Board ................................................279 Figure 147 Operating Principle of OHP Board ................................................ 281 Figure 148 Front Panel of OHP Board ..........................................................282 Figure 149 Operating Principle of NCPF Board (100 M Supervision System) ...... 284 Figure 150 Front Panel of NCPF Board .........................................................285 Figure 151 Operating Principle of OSCF Board ..............................................287 Figure 152 Front Panel of OSCF Board.........................................................288 Figure 153 Optical Connection between OSCF Board and OTU Board................ 291 Figure 154 Operating Principle of OHPF Board ..............................................293 Figure 155 Front Panel of OHPF Board.........................................................295 Figure 156 Operating Principle of APSF Board...............................................297 Figure 157 Front Panel of APSF Board .........................................................298 Figure 158 Operating Principle of PBX Board ................................................300 Figure 159 Front Panel and Rear Panel of PBX Board ..................................... 301 Figure 160 Relations between PWSB Board and Power Distribution Subrack ......303 Figure 161 Operating Principle of PWSB Board..............................................303 Figure 162 Front Panel of PWSB Board ........................................................304 Figure 163 DIP Switch on PWSB Board ........................................................305 Figure 164 DB15 Socket (male) ................................................................. 307 Figure 165 Operating Principle of CA Board ..................................................312 Figure 166 Front Panel of CA Board ............................................................313 Figure 167 Operating Principle of CSU Board ..............................................317

Confidential and Proprietary Information of ZTE CORPORATION

363

ZXMP M900 (V2.20) Hardware Manual

Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure

168 169 170 171 172 173 174 175 176 177 178 179

Front Panel of CSU Board.........................................................319 Application of ZXWM M900 (no more than 48-Channel System).......323 Application of ZXWM M900 (80/96-Channel System) ..................... 324 Application of ZXWM M900 (160/176-Channel System) .................. 325 2 M Supervisory System............................................................332 100 M Supervisory System ........................................................336 Integrated Wavelength Supervision Subsystem............................. 342 Position of OWM Board in OTM Equipment.................................... 343 Position of OWM Board in OADM Equipment ................................. 344 Power Management Domain.......................................................348 Division of Power Management Domain (80-Channel System) .........349 Division of Power Management Domain (More Than 80 Channels)....350

364

Confidential and Proprietary Information of ZTE CORPORATION

Tables

Table 1 Chapter Summary ..................................................................................... ii Table 2 Typographical Conventions......................................................................... iv Table 3 Mouse Operation Conventions .................................................................... iv Table 4 Safety Signs ............................................................................................. v Table 5 Structural Parameters of ZTE Cabinet .............................................................1 Table 6 Cabinet Configurations of ZXWM M900 ...........................................................6 Table 7 Relations between Boards and Slots (for 2 M Supervisory System without APSF) 12 Table 8 Relations between Boards and Slots (for 2 M Supervisory System with APSF)..... 13 Table 9 Relationship between Boards and Slots (for 100 M Supervisory System)............ 14 Table 10 Serial Number of Racks ............................................................................ 16 Table 11 Serial Number of Subracks........................................................................ 17 Table 12 Type and Function of Interfaces on OA Backplane......................................... 17 Table 13 Signal Definition of Pins in J1/j17 Socket..................................................... 19 Table 14 Signal Definitions of Pins in J2 Socket ......................................................... 19 Table 15 Signal Definition of Pins in J8 Socket .......................................................... 20 Table 16 Signal Definition of Pins in J11 Socket......................................................... 20 Table 17 Signal Definition of Pins in J3 Socket .......................................................... 20 Table 18 Signal Definitions of Pins in J12 Socket ....................................................... 21 Table 19 Functions of Components in OTU Subrack ................................................... 22 Table 20 Type and Function of Interfaces on OTU Backplane ....................................... 24 Table 21 Relationship between Boards and Slots in TMUX Subrack............................... 26 Table 22 Types and Functions of Interface on TMUX Backplane ................................... 27 Table 23 Components Functions of Orderwire Phone Bracket....................................... 29 Table 24 Functions of Components in Independent Fan Unit........................................ 30 Table 25 Functions of Components in Power Distribution Subrack ................................ 33 Table 26 Functions of Components in Monitoring Plug-in Box ...................................... 34 Table 27 Structures of Components in ODF Plug-in Box .............................................. 36 Table 28 Functions of Components of DCM Plug-in Box .............................................. 37 Table 29 Available Boards for ZXWM M900 ............................................................... 39 Table 30 Front Panel Descriptions of OTU Board and Related Operation Information ....... 48 Table 31 Relations between OTU Board and Indicator Status....................................... 49 Table 32 Performance and Alarm Messages of OTU Board........................................... 50 Table 33 Front Panel Description of OTUF Board and Related Operation Information ....... 55 Table 34 Performance and Alarm Messages of OTUF Board ......................................... 57 Table 35 Front Panel Descriptions of OTU10G Board and Related Operation Information . 63 Table 36 Performance and Alarm Messages of OTU10G Board ..................................... 64
Confidential and Proprietary Information of ZTE CORPORATION 365

ZXMP M900 (V2.20) Hardware Manual

Table 37 Signal Definition of EOUT10G Board ........................................................... 68 Table 38 Description of EOTU10G Boards Front Panel and Related Operation Information .................................................................................................................. 70 Table 39 Performance, Alarm and Event Messages of OTU10G Board.......................... 71 Table 40 Functions of SRM41/SRM42 Board.............................................................. 75 Table 41 Front Panel Descriptions of SRM42/SRM41 Board and Related Operation Information .................................................................................................................. 79 Table 42 Correspondence Relations between the Working Status and Indicator Status of the SRM41/SRM42 Board..................................................................................... 80 Table 43 Performance Messages of SRM42/SRM41 Board ........................................... 82 Table 44 Alarm Messages of SRM42/SRM41 Board..................................................... 84 Table 45 Event Messages of SRM42/SRM41 Board ..................................................... 86 Table 46 Description of GEM2 Boards Front Panel and Related Operation Information .. 89 Table 47 Relations between the Working Status and Indicator Status of GEM2 Board .... 91 Table 48 Performance Messages of GEM2 Board ...................................................... 91 Table 49 Alarm Messages of GEM2 Board ............................................................... 92 Table 50 Front Panel Descriptions of GEMF Board and Related Operation Information ..... 97 Table 51 Correspondence Relations between the Working Status and Indicator Status of GEMF Board ................................................................................................. 98 Table 52 Performance Messages of GEMF Board ........................................................ 99 Table 53 Alarm Messages of GEMF Board ............................................................... 100 Table 54 Description of GEM8s Front Panel and Related Operation Information ......... 105 Table 55 Relations between the Working Status and Indicator Status of GEM8 Board .. 106 Table 56 Performance Messages of GEM8 Board .................................................... 106 Table 57 Alarm Messages of GEM8 Board ............................................................. 108 Table 58 Event Messages of GEM8 Board ............................................................. 111 Table 59 Descriptions of DSA Boards Front Panel and Related Operation Information . 115 Table 60 Relations between the Working Status and Indicator Status of DSA Board .... 116 Table 61 Performance Messages of DSA Board ...................................................... 119 Table 62 Alarm Messages of DSA Board ............................................................... 121 Table 63 Event Messages of DSA Board................................................................ 123 Table 64 Types of DSAF Board............................................................................ 125 Table 65 Description of DSAF Boards Front Panel and Related Operation Information . 129 Table 66 Relations Between Working Status and Indicator Status of DSAF Board........ 130 Table 67 Performance Messages of DSAF Board .................................................... 130 Table 68 Alarm Messages of DSAF Board.............................................................. 132 Table 69 Event Messages of DSAF Board .............................................................. 134 Table 70 Description of DSAE Boards Front Panel and Related Operation Information. 140 Table 71 Relations Between the Working Status and Indicator Status of DSAE Board .. 140 Table 72 Performance Messages of DSAE Board .................................................... 143 Table 73 Alarm Messages of DSAE Board ............................................................. 143 Table 74 Event Messages of DSAE Board .............................................................. 145 Table 75 Table 76
366

Description of SMU Boards Front Panel and Related Operation Information .. 149 Relations Between the Working Status and Indicator Status of SMU Board ... 150

Confidential and Proprietary Information of ZTE CORPORATION

Tables

Table 77 Performance Messages of SMU Board...................................................... 150 Table 78 Alarm Messages of SMU Board ............................................................... 151 Table 79 Event Messages of SMU Board ............................................................... 153 Table 80 Front Panel Descriptions of OCI Board and Related Basic Operation............... 157 Table 81 Performance and Alarm Messages of OCI Board ......................................... 159 Table 82 Front Panel Descriptions of OBM Board and Related Basic Operation.............. 162 Table 83 Performance and Alarm Messages of OBM Board ........................................ 165 Table 84 Type List of OMU Board .......................................................................... 166 Table 85 Front Panel Descriptions of OMU Board and Related Basic Operation ............. 168 Table 86 Performance and Alarm Messages of OMU Board ........................................ 170 Table 87 Front Panel Descriptions of VMUX Board and Related Basic Operation ............ 174 Table 88 Performance and Alarm Messages of VMUX Board....................................... 175 Table 89 Type List of ODU Board .......................................................................... 176 Table 90 Front Panel Descriptions of ODU Board and Related Basic Operation.............. 178 Table 91 Performance and Alarm Messages of ODU Board ........................................ 180 Table 92 Front Panel Descriptions of OAD Board and Related Basic Operation .............. 183 Table 93 Performance and Alarm Messages of OAD Board ........................................ 185 Table 94 WBU Board Type ................................................................................... 186 Table 95 Front Panel Descriptions of WBU Board and Related Basic Operations .......... 188 Table 96 Performance, Alarm and Event Messages of WBU Board............................. 191 Table 97 Types of WSU Board............................................................................. 192 Table 98 Front Panel Descriptions of WSU Board and Related Basic Operations .......... 197 Table 99 Performance, Alarm and Event Messages of WSU Board............................. 200 Table 100 Table 101 Description of WBM Boards Front Panel and Related Operation Information 203 Performance, Alarm and Event Messages of WBM Board .......................... 205

Table 102 Front Panel Descriptions of SDM Board and Related Basic Operations........... 207 Table 103 Performance and Alarm Messages of SDM Board....................................... 209 Table 104 Type List of EOA Board ......................................................................... 210 Table 105 List of Board Subtype ........................................................................... 211 Table 106 Front Panel Descriptions of EOBA Board and Related Basic Operations ......... 216 Table 107 Front Panel Descriptions of EOLA Board and Related Basic Operations.......... 218 Table 108 Front Panel Descriptions of EOPA Board and Related Basic Operations ......... 220 Table 109 Front Panel Descriptions of EONA Board and Related Basic Operations ......... 222 Table 110 Performance Messages of EOA Board ...................................................... 224 Table 111 Alarm Messages of EOA Board ............................................................... 225 Table 112 Event Messages of EOA Board................................................................ 226 Table 113 Front Panel Descriptions of DRA Board and Related Basic Operations ........... 229 Table 114 Performance and Alarm Messages of DRA Board ....................................... 231 Table 115 Front Panel Descriptions of LAC Board and Related Basic Operations ........... 234 Table 116 Performance and Alarm Messages of LAC Board........................................ 236 Table 117 Front Panel Descriptions of OWM Board and Related Basic Operations.......... 238 Table 118 Performance and Alarm Messages of OWM Board...................................... 240 Table 119 Front Panel Descriptions of OPM Board and Related Basic Operations........... 242 Table 120 Performance and Alarm Messages of OPM Board....................................... 243
Confidential and Proprietary Information of ZTE CORPORATION 367

ZXMP M900 (V2.20) Hardware Manual

Table 121 Performance and Alarm Messages of MCPD Board ..................................... 246 Table 122 Front Panel Descriptions of MCPD Board and Related Basic Operations ......... 247 Table 123 Front Panel Descriptions of OP Board and Related Basic Operations ............. 249 Table 124 Correspondence Relations between the Working Status and Indicator Status of OP Board ........................................................................................................ 250 Table 125 Performance and Alarm Messages of OP Board ......................................... 255 Table 126 Table 127 Table 129 Table 130 Front Panel Descriptions of OPMS Board and Related Basic Operations ....... 257 Relations between the Working Status and Indicator Status of OPMS Board 259 Front Panel Descriptions of OPCS Board and Related Basic Operations ....... 262 Performance, Alarm and Event Messages of OPCS Board.......................... 264

Table 128 Event Messages of OPMS Board............................................................ 259

Table 131 Front Panel Descriptions of OMCP Board and Related Basic Operations......... 267 Table 132 Correspondence Relations between the Working Status and Indicator Status of OMCP Board ............................................................................................... 268 Table 133 Performance and Alarm Messages of OMCP Board ..................................... 271 Table 134 Front Panel Descriptions of NCP Board and Related Basic Operations ........... 273 Table 135 Correspondence Relations between the Working Status and the Indicator Status of NCP/NCPF Board ......................................................................................... 274 Table 136 Performance and Alarm Messages of NCP Board ....................................... 275 Table 137 Front Panel Descriptions of OSC Board and Related Basic Operations ........... 277 Table 138 Performance and Alarm Messages of OSC Board ....................................... 279 Table 139 Front Panel Descriptions of OHP Board and Related Basic Operations ........... 283 Table 140 Performance and Alarm Messages of OHP Board ....................................... 283 Table 141 Front Panel Descriptions of NCPF Board and Related Basic Operations.......... 285 Table 142 Front Panel Descriptions of OSCF Board and Related Basic Operations ......... 288 Table 143 Correspondence Relations between the Working Status and the Indicator Status of OSCF Board................................................................................................ 289 Table 144 Correspondence Relations between the Working Status and the Indicator Status of the Optical/Electrical Interfaces on OSCF Board ............................................... 290 Table 145 Performance and Alarm Messages of OSCF Board ..................................... 292 Table 146 Front Panel Descriptions of OHPF Board and Related Basic Operations ......... 295 Table 147 Performance and Alarm Messages of OHPF Board ..................................... 296 Table 148 Front Panel Descriptions of APSF Board and Related Basic Operations .......... 298 Table 149 Correspondence Relations between the Working Status and the Indicator Status of APSF Board ................................................................................................ 299 Table 150 Panel Descriptions of PBX Board and Related Basic Operations.................... 301 Table 151 Performance and Alarm Messages .......................................................... 302 Table 152 Corresponding Relations between Running Status and Indicator Status of PWSB Board ........................................................................................................ 305 Table 153 Description of Cabinet No. ..................................................................... 305 Table 154 Definitions of Pins in -48_In1/-48_In2 Power Socket ................................. 306 Table 155 Definitions of Pins in Alm_In Socket........................................................ 306 Table 156 Definitions of Pins in Alm_Out Socket...................................................... 307 Table 157 Definitions of Pins in Warn Socket .......................................................... 308
368 Confidential and Proprietary Information of ZTE CORPORATION

Tables

Table 158 Definitions of Pins in Sp_Alm Socket ....................................................... 308 Table 159 Performance and Alarm Messages of PWSB Board..................................... 309 Table 160 Front Panel Descriptions of OAD Board and Related Basic Operation ............ 310 Table 161 Performance and Alarm Messages of FCB Board ....................................... 311 Table 162 Front Panel Descriptions of CA Board and Related Basic Operations ............. 313 Table 163 Correspondence Relations between the Working Status and Indicator Status of CA Board ........................................................................................................ 314 Table 164 Performance and Alarm Messages of CA Board ......................................... 316 Table 165 Table 166 Table 167 Front Panel Descriptions of CSU Board and Related Operation Information.. 319 Relations Between the Working Status and Indicator Status of CSU Board .. 320 Performance, Alarm and Event Messages of CSU Board............................ 321

Table 168 Wavelength Allocation (8/32/40 Channel, C Band) .................................... 326 Table 169 Wavelength Allocation (48/96 Channel, C Band) ....................................... 326 Table 170 Wavelength Allocation (80 Channel, C Band)............................................ 328 Table 171 Wavelength Allocation (80 Channel, L Band) ............................................ 329 Table 172 Requirements on the Creation of NEs in a 2 M Supervision System.............. 334 Table 173 Requirements on the Creation of NEs in a 100 M Supervision System .......... 338 Table 174 Configuration Principle of IP Address of Optical Interfaces on OSCF Board .... 339 Table 175 EMS Software Configurations of Integrated Wavelength Supervision Subsystem ................................................................................................................ 345 Table 176 Hardware/Software Needed in Power Management of OMS Layer ................ 349 Table 177 Working Conditions of OMS Layer Power Management ............................... 351 Table 178 Configurations of OMS Power Management Subsystem .............................. 354

Confidential and Proprietary Information of ZTE CORPORATION

369

ZXMP M900 (V2.20) Hardware Manual

370

Confidential and Proprietary Information of ZTE CORPORATION

Index

Index

3-pin power socket (J1/J17)...............19 APS ................................................13 APSF Board ................................... 296 Automatic Lock of Service Type ..........45 Basic Fittings in Cabinet ..................... 3

Alarm Panel ....................................4 Cable Area ......................................4 Front Door.......................................4 Grounding Copper Busbar ..............4 Heat Dissipation Aperture...............5 Mounting Hole ................................4 Outlet...............................................4
Board Slots Mode .............................12

Clock function ............................124 Clock Processing Unit ................127 Control and communication unit 156 Convergence & Framing Unit ....126 Coupler .......................................155 Interleaver ...................................155 Optical power monitoring module ................................................155 OTN Optical Module..................127 Tributary Optical Module ...........126 Tributary side..............................123
EOA Board .................................... 209

Boards arrangement for 100 M supervisory system....................14 Boards arrangement for 2 M supervisory system (with APSF) ...................................................13 Boards arrangement for 2 M supervisory system (without APSF)........................................12
CA Board ...................................... 311 Common Interface Area ....................15 CSU Board .................................... 316 DB9 socket (female) (J3/J12).............20 DB9 socket (male) (J2/J8/J11) ...........19 DCM Plug-in Box ..............................36 DeMUX module .............................. 155 DRA Board .................................... 226

EOBA .................................210, 215 EOLA..................................210, 217 EOPA..........................210, 219, 221


EVOA ........................................... 232 FCB Board..................................... 310 GEM2 Board .................................... 86 GEM8 Board .................................. 102 GEMF Board

Aggregate side ..............................94 Control and communication unit ..96 Demultiplexing direction ..............95 GE convergence unit.....................95 GE optical module ........................95 Multiplexing direction ..................94 OTN optical module .....................96 OTN processing unit.....................95 Tributary side................................94
GEMF Board .................................... 94 GFP data encapsulation format......... 135 Independent Fan Unit ....................... 29 J10 ............................................... 16 LAC Board

C-band RAMAN module............228 L-band RAMAN module ............228


DSA Board .................................... 111 DSAE Board................................... 136 DSAF Board ................................... 123

Aggregate side ............................124

Control and communication unit 233


371

Confidential and Proprietary Information of ZTE CORPORATION

ZXMP M900 (V2.20) Hardware Manual

Coupler........................................233 EVOA .........................................233 EVOA drive circuit .....................233 GFF .............................................233 LACG..........................................232 LACT ..........................................232 Optical power measuring unit.....233
LAC Board ..................................... 232 MAC controller unit ...........................95 Manual Lock of Service Rate...............45 Manual Lock of Service Type ..............45 Monitoring Plug-in Box ......................34 MUX module .................................. 155 NCP Board..................................... 271 NCPF Board ................................... 283 Non-specific wavelength optical transmitting module......................47 OA Board

Optical power monitoring module ................................161, 167, 177


OCI Board..................................... 154 ODF Plug-in Box .............................. 34 ODU Board.................................... 176

Control and communication unit 181 OADM ........................................181 Optical power monitoring module ................................................181
OHP Board .................................... 280

Control and communication information processing ...........281 Orderwire overhead information processing ...............................281 Transparent user channel information processing ...........281
OHPF Board .................................. 293 OLA ................................................. 7 OMCP Board .................................. 265

1510/1550 multiplexer ........213, 214 A1510/1550 demultiplexer .213, 214 Control and communication unit214, 215 Coupler................................213, 214 EDFA, EDFA drive circuit .213, 215 Optical power monitoring module .........................................213, 215
OA redundancy mode...................... 254 OA shared configuration mode.......... 253 OA Subrack ...................................... 9

Control and communication unit 266 Optical switch module ................265


OMU Board

OMU16 .......................................166 OMU32 .......................................166 OMU40 .......................................166 OMU8 .........................................166 OMU80 .......................................166
OMU Board ................................... 166 OP Board ...................................... 247

Backplane......................................10 Board area .....................................10 Chute .............................................10 Dustproof net ................................10 Fan area.........................................10 Fiber cable reel-in box ..................11 Lug ................................................10 Orderwire phone bracket...............10
OAD Board .................................... 181 OADM .............................................. 7 OBM Board .................................... 160

concurrent transmitting direction 248 OCH 1+1 Protection ...................251 OMS 1+1 Protection ...................253 preferred receiving direction.......248
OPCS Board .................................. 260 OPM Board .................................... 240 OPMS Board .................................. 255 Orderwire Phone Bracket................... 29 OSC Board .................................... 275

OSCL ..........................................275 OSCT ..........................................275


OSCF Board .................................. 286 OTM................................................. 7 OTU Board

Broadband multiplexer................161 Control and communication unit161, 167, 177 Coupler........................161, 167, 177
372

client side ......................................44

Confidential and Proprietary Information of ZTE CORPORATION

Index

Control and communication unit ..47 line side .........................................44 Optical receiving module..............46 Optical transmitting module .........47 OTU (Regenerator, OTUG) ..........45 OTU (Terminal) ............................44 Performance and overhead supervision unit.........................47
OTU Board ......................................44 OTU redundancy configuration mode . 251 OTU shared configuration mode........ 252 OTU Subrack ...................................21

PBX Board .................................... 300 PCB ............................................... 42 Power Alarm Subrack ....................... 31 Power Distribution Subrack................ 32 PWSB Board .................................. 302 RAMAN ......................................... 226 RM41/SRM42 board.......................... 77

Aggregate optical module.............77 Clock processing unit ...................78 Control and communication unit ..78 Convergence unit ..........................77 Tributary optical module ..............77
SDH overhead processing unit ........... 95 SDM Board.................................... 205 Serial number of cabinet ................... 16 Serial number of subrack .................. 16 Slots for PBX Boards......................... 17 SMU Board.................................... 145 Specific wavelength optical transmitting module ....................................... 47 Structure of Boards in OA/OTU/TMUX Subrack ...................................... 41 Structure of FCB Board ..................... 43 Structure of PBX Board ..................... 42 Structure of PWSB Board .................. 43 TMUX Subrack ................................. 25 VMUX Board .................................. 171

Board Slots....................................23 Common Interface Area................24


OTU10G Board .................................65 OTUF Board

AFEC ............................................60 Control and communication unit ..54 Control and Communication Unit.69 FEC ...............................................60 FEC framer....................................54 FEC Framer...................................69 Optical receiving module..............54 Optical Receiving Module ............69 Optical transmitting module .........54 Optical Transmitting Module........69 Regenerator OTU10G (OTU10G G) ...................................................60 Regenerator OTUF (OTUFG).......52 Single-channel bidirectional OTU10G ...................................59 Terminal OTUF ............................51
OTUF Board .....................................51 OWM Board ................................... 236

12 optical switch .......................237 Control and communication unit 238 Drive circuits...............................237 TF................................................237 Wavelength supervisor................237

AWG...........................................172 Control and communication unit 173 Coupler .......................................172 Optical power monitoring module ................................................173 Temperature control and drive circuit ......................................172 VOA............................................172
VOA ............................................. 171 WBM Board ................................... 200 WBU Board ................................... 185 WSU Board ................................... 191

Confidential and Proprietary Information of ZTE CORPORATION

373

You might also like