You are on page 1of 3

Design Of Columns

Step 1 Given :Fck= Fy= b D

30 500 Size Of Column 1000 1500

Mpa N/mm^2 mm mm

Pu Mux Muy

Design Load & Moments 17955 KN 845 KN-m 530 KN-m 40 mm 32 mm 56 mm

Clear Cover= Bar Dia. = d' = Step 2

Check for short or slender column

unsupported length Lx = 4.5 m unsupported length Ly= 4.5 m Leffx/Lx = 0.65 Leffy/Ly = 0.65 Leffx= 2.925 m Leffy= 2.925 m Leffx/D = 1.95 Leffy/b = 2.925 Result Leffy/b <12 therefore column is short Assume % steel = 1.1

Moments due to minimum eccentricity


minimum eccentricity
Cl 25.4 moments due to minimum eccentricity

ex 0.059

ey 0.042

Mex,kN.m Mey,kN.m
0.27 760.10

Total moments to be considered for column design are: Mux Muy Pu/fck bD p/fck interaction diagram d//D Mux1/fck b D2 kN.m kN.m
845.00 760.10 0.399 0.04 0.04 0.14

interaction diagram d//b 0.06

Puz =

26214.75 KN

Pu/Puz
Cl 39.6

an
Cl 39.6

(Mux/Mux1)an + (Muy/Muy1)an < 1


IS 456-2000 Cl 39.6

Result
39.6

Cl

0.685 Area of steel=

1.808

0.11

<1 Ok

16500 mm^2

Longitudinal Reinforcement
Nos. 11 10 Reinf. details at support dia Asc mm2 mm 32 32 16889.20
p prov.

%
1.13

Transverse Reinforcement Diameter of lateral ties = Spacing = 300

8 mm

mm

interaction diagram
Muy1/fck D b
2

Mux1 kN.m
9450.000

Muy1 kN.m
2700.000

0.06