Inclusion Analysis as per ASTM E 45 method A and D (E 1122)

Date & Time: 2004-07-09, 13:40:31 Organization: Clemex Technolgies Inc. Department: Laboratory User Name: Myriam Savard Eng. Magnification: 100x Calibration: 0.9741 mic. Rating - Method A

Field Area (mic.2): Field(s) Analyzed: Total Analyzed Area (mic.2): Total Analyzed Area (mm2): Sample ID: Heat ID:

297702.70 6 1268056.269 1.268 InclusionsAnalysis eg Customer x

Rating of worst field for each type Type A 1.0 0.5 Type B 1.5 2.0 Type C 1.0 0 Type D 0.5 0.5

Thin: Heavy:

Rating - Method D Quantity of fields for each severity level 0 4 5 1 5 5 6 5 6 0.5 1 1 0 0 0 0 1 0 1 1 0 1 0 1 0 0 0 1.5 0 0 4 0 0 0 0 0 2 0 0 0 1 0 0 0 0 2.5 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 3.5 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 4.5 0 0 0 0 0 0 0 0 5 0 0 0 0 0 0 0 0

Type A (Sulfide)

Thin Heavy Thin Heavy Thin Heavy Thin Heavy

Type B (Alumina)

Type C (Silicate)

Type D (Globular)

Oversize Inclusions

Oversize by length Count: Length max: Oversize by mean width Count: Length max:

Type A 0 0.00 Type A 0 0.00

Type B 0 0.00 Type B 0 0.00

Type C 0 0.00 Type C 0 0.00

Type D 0 0.00 Type D 2 19.78

Total 0

Total 2