You are on page 1of 2

M-Bus Module - Overview

Module Type MC III. Pulse Input MC III. Pulse Output MC 66-C. Pulse Input MC 66-C. Pulse Output MC 66-C. Pulse Input MCC. No pulse conn. MC 401. Pulse Input MC 401. Pulse Input New generation MC 402. Pulse Input MC 402. Pulse Output MC 402. MC III compatible Data. Pulse Input MC 601. Base module. Pulse Input MC 601. Top module. MC 601. Base module. Alternative registers. InA MC 602. Medium data. Pulse Input MC 601. MC III compatible Data. Pulse Input *) Require top module 6706 Order No. 6604 6607 6608 6609 660V 660S 660S 660P 402 0 20 402 0 21 402 0 29 6700 20 6707 00 6700 27 6700 28 6700 29 Module No. 413 583 554 552 1130 515 665 710 1030 1007 1140 831 838 997 1104 1125 + + + + + + + + + + + + + + + + + + + + MCC MC 401 MC 402 MC III + + MC 66 + + + + + MC 601 (+)* (+)* (+)* (+)* MC 602 MC 801 Old master + + + + + + + MBM 250D + + + + + + + + + + + + + + + +
58101092_GB_08.05.2012

M-Bus registers from MULTICAL in M-Bus Master 250D


Data
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48.

Module MC III 6604, 6607, 660V, 660S,


Meter number Primary address Manufacturer ID Heat energy E1 Volume V1 Hour counter Temp. flow Temp. return Differential temp. Actual power Actual flow Heat energy E1, Target Volume V1, Target Target date M-Bus Status M-Bus Version M-Bus Access Nr. M-Bus Device Type Meter type Meter number Max. power Info Tariff 2 Tariff limit 2 Tariff 3 Tariff limit 3 Pulse input A Pulse input B Program number Config number Date

MC 66-C 6608, 6609


Meter number Primary address Manufacturer ID Heat energy E1 Volume V1 Hour counter Temp. flow Temp. return Differential temp. Actual power Actual flow Heat energy E1, Target Volume V1, Target Target date M-Bus Status M-Bus Version M-Bus Access Nr. M-Bus Device Type Meter type Meter number Max. power Info Tariff 2 Tariff limit 2 Tariff 3 Tariff limit 3 Pulse input A Pulse input B Program number Config number Date Energy 8 (m3*tf) Energy 9 (m3*tr) Cooling energy E3 Max power, Target

MC 401 660P
Meter number Primary address Manufacturer ID Serial number Heat energy E1 Volume V1 Hour counter Temp. flow Temp. return Differential temp. Actual power Max. power Actual flow Max. flow Pulse input A Pulse input B Date / time Heat energy E1, Target Volume V1, Target Max. power, Target Max flow, Target Pulse input A, Target Pulse input B, Target Target date M-Bus Status M-Bus Version M-Bus Access Nr. M-Bus Device Type Info Tariff 2 Tariff limit 2 Tariff 3 Tariff limit 3 Tariff 2, Target Tariff 3, Target Program number Config number Meter type Meter SW Rev. Module type Module SW Rev.

MC 402, MC 601 standard MC 601 alternative 402 0 20, 402 0 21, 670027
Meter number Primary address Manufacturer ID Serial number Heat energy E1 Volume V1 Hour counter Temp. Flow Temp. return Differential temp. Actual power Max. power Actual flow Max. flow Tariff 2 Tariff 3 Pulse input A Pulse input B Cooling energy E3 Date / time Heat energy E1, Target Volume V1, Target Max. power, Target Max flow, Target Tariff 2, Target Tariff 3, Target Pulse input A, Target Pulse input B, Target Cooling E3, Target Target date M-Bus Status M-Bus Version M-Bus Access Nr. M-Bus Device Type Info Energy E8 (m3*tf) Energy E9(m3*tr) Tariff limit 2 Tariff limit 3 Program number Config number 1 Config number 2 Meter number 1 Meter number 2 Meter type Meter SW Rev. Module type Module SW Rev. Meter number Primary address Manufacturer ID Serial number Heat energy E1 Volume V1 Hour counter Temp. Flow Temp. Return Differential temp. Temp 3 Temp 4 Actual power Actual flow V1 Actual flow V2 Max. flow V1 Pulse input A Cooling energy E3 Flow energy E4 Return flow energy E5 Tap water energy E6 Volume V2 Mass 1 Mass 2 Date / time Heat energy E1, Target Volume V1, Target Max. flow V1, Target Pulse input A, Target Cooling energy E3, Target Tap water energy E6, Target Volume V2, Target Target date M-Bus Status M-Bus Version M-Bus Access Nr. M-Bus Device Type Info Program number Config number 1 Config number 2 Meter number 1 Meter number 2 Meter type Meter SW Rev. Module type Module SW Rev.

MC 602 medium 670028


Meter number Primary address Manufacturer ID Serial number Heat energy E1 Volume V1 Hour counter Error hour counter Temp. Flow Temp. Return Differential temp. Actual power Max. power Actual flow Max. flow Pulse input A Pulse input B Cooling energy E3 Date / time Heat energy E1, Target* Volume V1, Target* Max. power, Target* Max flow, Target* Pulse input A, Target* Pulse input B, Target* Cooling E3, Target* Target date* M-Bus Status M-Bus Version M-Bus Access Nr. M-Bus Device Type Info Program number Config number 1 Config number 2 Meter number 1 Meter number 2 Meter type Meter SW Rev. Module type Module SW Rev.

* Monthly data

58101092_GB_08.05.2012