Requirements No leaks in vacuum lines or hose connections. Vacuum hoses not clogged or kinked Pressure hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked
Test sequence NOTE: Do not use pressurized air for the following test.
Zoom
Disconnect vacuum hose -1- at Secondary Air Injection (AIR) Solenoid Valve -N112- (-2-).
Zoom
Disconnect pressure hose -3- at Secondary Air Injection (AIR) pump motor and blow air in with light pressure (arrow).
Combination valve must close. NOTE: To disengage, compress the buttons at the hose coupling. Operate vacuum pump.