Instant.Short Circuit Tripping Setting of C.

Cu

Selection of Circuit Fus

Alu
Phase
Voltage(L-L)
Voltage(L-N)
Instantaneous Short-Circuit Triping Set
Accuracy
Cable Size

Circuit Wire Size


440
230
100
20
3cx4

Volt
Volt
Amp
%
4

Cable Material
Actual Length of Cable

Cu
5

Meter

Max.Length of Cable for your Tripping setting


Your Tripping Setting of C.B is

133
OK

Circuit Fuse Size(Max)

Search Cable Amper Rating


Type of Cable
Mt.
Current Capacity of Cable

Jignesh.Parmar
www.electricalnotes.wordpress.com
jiguparmar@yahoo.com

election of Circuit Fuse


mm2
325

55
Amp

h Cable Amper Rating (Appro)

acity of Cable

AL

HT XLPE

1cx240

440

Amp

CURRENT RATING
AWG
mm2
AL
CU
PVC
HRPVC
LT XLPE
HT XLPE
EPR CSP

PVC

X-SECTION

55

1
2
3
4

3cx1.5
3cx2.5
3cx4
3cx6

AL
14
18
23
30

5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

3cx10
3cx16
3cx25
3cx35
3cx50
3cx70
3cx95
3cx120
3cx150
3cx185
3cx225
3cx240
3cx300
3cx400
3cx500
3cx630
1cx120
1cx150
1cx185
1cx225
1cx240

39
50
63
77
95
130
155
180
205
240
255
280
315
375
425
480
220
250
290
315
335

26

1cx300

380

27
28
29

1cx400
1CX500
1cx630

435
480
550

AL
0
0
0
440
0

CU
0
0
0
0
0

PVC
HRPVC
LT XLPE
HT XLPE
EPR CSP

CABLE DATA
CURRENT RATING AT 40 DEG (LAID IN TUNNEL)
PVC
HRPVC
LT XLPE
AL
CU
CU
AL
CU
17
16
21
24
22
29
30
28
37
31
36
39
37
48
50
47

HT XLPE -upto
6.6kv(E)
AL
CU

EPR CSP
CU
26
35
46

57
65
66
110
135
155
200
230
255
305
335
355
400
455
521
674
280
320
370
400
425

49
62
85
105
128
159
189
220
250
293
323
342
384
458
519
586
268
305
354
390
409

63
81
110
134
165
201
244
281
323
372
407
433
488
555
635
759
342
390
451
483
519

67
70
96
117
142
179
221
257
292
337
379
399
455
530
612
707
268
309
360
408
433

62
79
108
132
162
198
240
276
318
366
402
426
480
546
612
685
336
384
444
479
510

100
121
145
181
221
254
290
330
369
390
450
525
609
706
277
318
370
412
440

115
140
175
215
255
290
335
370
415
440
505
600
714
850
368
422
490
547
580

64
85
114
140
175
216
260
303
349
398
372
348
325
304
284
265
299
343
391
366
342

475

464

580

501

570

509

665

320

550
590
660

531
586
671

671
720
805

596
693
814

660
708
825

600
700
817

805
900
1030

299
279
261

440

Motor starter Selection


Auto Transformer Starting
230V
440V

Part Winding Starting


Star-Delta Starting
230V
440V
230V
440V

oo
oo
1
2

Full Voltage Starting


230V
440V
1.5 Hp
2 Hp
3 Hp
5 Hp
7.5 Hp
10 Hp
15 Hp
25 Hp

7.5 Hp
15 Hp

10 Hp
25 Hp

10 Hp
25 Hp

30 Hp

50 Hp

30 Hp

50 Hp

50 Hp

4
5
6
7
8
9

50 Hp
100 Hp
200 Hp
300 Hp
450 Hp
800 Hp

100 Hp
200 Hp
400 Hp
600 Hp
900 Hp
1600 Hp

50 Hp
100 Hp
200 Hp
300 Hp
450 Hp
800 Hp

100 Hp
200 Hp
400 Hp
600 Hp
900 Hp
1600 Hp

75 Hp
150 Hp
300 Hp
450 Hp
700 Hp
1300 Hp

NEMA Size

Hp

FLA

Instantanous C.B

Time Delay Fuse

Jignesh.Parmar www.electricalno

Motor Data
Motor Rating
System Voltage V (L-L)
Supplay Frequency
Pole
Motor Spped
Locked Rotor Code
Motor Demand Factor
Motor Service Factor
Motor Operating Temperature
Motor Starting Method
Motor Starting P.F
Motor Running P.F
Motor Full Load Efficiency

30
415
50
4
1000
B
1
2
30
Dol
0.8
92%

Kw 30.00
Volt 3 Ph
Hz
No
Rpm

Jignesh.Parmar www.electricalnotes.wordpress.com jiguparmar@yahoo.com

Motor Details
Motor Consumed Load
Motor Starting Current
Motor Full Load Current
Syncronus Spped(Ns)
Slip
Locked Rotor Current (LRA)

32.61
567.08
56.71
1500
33.33
104.31

Kw
Amp
Amp
Rpm
%
Amp

Maximum Size of OverLoad Perotection

70.89

Amp

Standared(On Time Delay) Fuse (Max)


On Time Delay Fuse (Max)
Instantaneous Trip C.B(Max)
Inverstime C.B(Max)

170.13
99.24
453.67
141.77

Amp
Amp
Amp
Amp

22.38

Dol
Hp
Kw
1 Ph
3 Ph
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V

Y-D
Auto Tra.
Soft
Freq.Conv

3.35
0
3.15
3.55
4
4.5
5
5.6
6.3
7.1
8
9
10
11.2
12.5
14
16
18
20
24

3.15
3.55
4
4.5
5
5.6
6.3
7.1
8
9
10
11.2
12.5
14
16
18
20
24