Professional Documents
Culture Documents
CONTOH PERHITUNGAN
B.1 Aliran Co-Current
Percobaan 1
Thi
= 37 oC = 310,15 K
Thm = 35 oC = 308,15 K
Tho
= 34 oC = 307,15 K
Tci
= 29 oC = 302,15 K
Tcm = 29 oC = 302,15 K
Tco
= 30 oC = 303,15 K
Densitas (g/cm3)
0,99708
0,99568
0,99225
0,98807
C dan 29 oC
37 30
x (0,99225- 0,99568) 0,993279g/cm3
40 30
37 30
x (4,181- 4,181) 4,181J g/K
40 30
29 25
x (0,99568- 0,99708) 0,99596 g/cm3
30 25
29 25
x (4,181- 4,182) 4,1812 J g/K
30 25
= 186,8807 J/s
= 69,4051 J/s
Wloss = WE WA
= 186,8807 69,4051
= 117,4755 J/s
3. Perhitungan Efisiensi
a. Efisiensi Daya
EFFD =
WA
186,8807
x 100 %
x 100 % 37,1387 %
WE
69 ,4051
Thi - Tho
x 100 %
Thi - Tci
310,15 - 307,15
x 100 %
310,15 - 302,15
= 37,5 %
Tco - Tci
x 100 %
Thi - Tci
303,15 - 302,15
x 100 %
310,15 - 302,15
= 12,5 %
d. Efisiensi Rata-rata
EFFM
EFFH EFFC
2
(37,5 12,5) %
2
= 25 %
4. Perhitungan TLMTD
TLMTD
(T ho - Tco) - (T hi - Tci)
Tho - Tco
ln
Thi - Tci
310,15 - 302,15
= 5,7708 K
69,4051
WA
179 ,5074 J/s m 2 K
=
TLMTD.A 5,7708.0,0 67
= 37 oC = 310,15 K
Thm = 35 oC = 308,15 K
Tho
= 34 oC = 307,15 K
Tci
= 29 oC = 302,15 K
Tcm = 30 oC = 303,15 K
Tco
= 31 oC = 304,15 K
Dari tabel B.1 dan B.2 diperoleh nilai densitas () dan kapasitas panas (Cp) pada 37
o
C dan 30 oC
37 30
x (0,99225- 0,99568) 0,993279g/cm3
40 30
37 30
x (4,181- 4,181) 4,181J g/K
40 30
29 25
x (0,99568- 0,99708) 0,99596 g/cm3
30 25
29 25
x (4,181- 4,182) 4,1812 J g/K
30 25
= 186,8807 J/s
= 138,8103 J/s
Wloss = WE WA
= 186,8807 138,8103
= 48,0704 J/s
3. Perhitungan Efisiensi
a. Efisiensi Daya
EFFD
WA
138,8103
x 100 %
x 100 % 74,2775 %
WE
186 ,8807
Thi - Tho
x 100 %
Thi - Tci
310,15 - 307,65
x 100 %
310,15 - 302,15
= 37,5 %
c. Efisiensi Temperatur Fluida Dingin
EFFC
Tci - Tco
x 100 %
Thi - Tci
302,15 - 304,15
x 100 %
310,15 - 302,15
= 25 %
d. Efisiensi Rata-rata
EFFM
EFFH EFFC
2
(37,5 25) %
2
= 31,25 %
4. Perhitungan TLMTD
TLMTD
(T ho - Tco) - (T hi - Tci)
Tho - Tco
ln
Thi - Tci
310,15 - 302,15
= 5,4848 K
138,8103
WA
377 ,7329 J/s m 2 K
=
TLMTD.A 5,4848.0,0 67