General Design data: Cationic operating capacity* Anionic operating capacity* Water TDS max. Regeneration cycle No.

cationic column No. anionic column Water outlet with co-current regeneration* 1 eq/L 0,5 eq/L 500 ppm Small scale: Large scale: Small scale: Large scale: Small scale: Large scale: < 30 uS/cm 24 hrs / column 6 hrs / column 1 2 1 2

Water outlet with counter -current regeneration*< 5 uS/cm Recovery at 500 ppm TDS 76% *Indicative values for feed tap water at TDS = 500 ppm Small-scale IX demi plants data for 500 mg/L TDS tap water*: Flows (L/h) Bed depth (m) SAC resin volume (L) SBA resin volume (L) SAC column diameter (mm) SBA column diameter (mm) Co-current Reg. HCl 33% (kg / reg.) Co-current Reg. NaOH 50% (kg / reg.) Counter-current Reg. HCL 33% (kg / reg.) Counter-current Reg. NaOH 50% (kg / reg.) Large-scale IX demi plants Flows (m3/h) Bed depth (m) SAC resin volume (L) / column SBA resin volume (L) SAC column diameter (m) SBA column diameter (m) 100 0.8 25 50 200 285 6 8 3 4 200 0.8 50 100 285 400 12 16 6 8 500 0.8 125 250 450 630 30 40 15 20 1000 0.8 250 500 630 900 60 80 30 40

data for 500 mg/L TDS tap water: 5 0.8 315 630 0.7 1 10 0.8 630 1260 1 1.4 150 200 75 20 0.8 1260 2520 1.4 2 300 400 150 50 1 3150 6300 2 2.8 770 1000 385 70 1.2 4410 8820 2.2 3.0 1070 1410 535

Co-current Reg. HCl 33% (kg / 75 reg.) Co-current Reg. NaOH 50% (kg 100 / reg.) Counter-current Reg. HCL 33% 37,5 (kg / reg.)

Counter-current Reg. NaOH 50% (kg / reg.)

50

100

200

500

705

Read more: http://www.lenntech.com/ix-demi-plants.htm#ixzz2i3lHkrcZ