ALARME

SIGNIFICADO

O QUE

O QUE FAZER

NO SIGNAL

SEM SINAL

VERIFICAR COM "LED" SINAL NA PONTA DO CABO COAXIAL LIGADO SEM SINAL ELTRICO OU NA RX DA INTERFACE ELTRICA. PTICO NA RX DA VERIFICAR SINAL PTICO CHEGANDO INTERFACE NA PONTA DO CORDO LIGADO NA RX DA INTERFACE.

LOS

LOSS OF SIGNAL PERDA DE SINAL

SEM SINAL ELTRICO OU PTICO NA RX DA INTERFACE

EFETUAR UM LOOP NA INTERFACE (LIGAR RX COM TX), E VERIFICAR SE O ALARME NORMALIZA.

AIS

ALARM INDICATOR SIGNAL SINAL INDICADOR DE ALARME

A INTERFACE REMOTA (OUTRO LADO DO LINK) EST COM ALARME DE LOS

EFETUAR UM LOOP NA INTERFACE REMOTA E VERIFICAR SE O ALARME NORMALIZA. SE NORMALIZAR : VERIFICAR OS CABOS QUE ESTO LIGASO A INTERFACE REMOTA. SE NO NORMALIZAR : VERIFICAR DID OU DGO NO LADO REMOTO.

LOF

LOSS OF FRAME PERDA DE QUADRO

VERIFICAR SE O EQUIPAMENTO DE TESTE EST CONFIGURADO O TIPO DE QUADRO CORRETAMENTE. (PCM) NO EST SENDO VERIFICAR SE OS EQUIPAMENTOS RECONHECIDO. DAS PONTAS ESTO TRANSMITINDO COM O MESMO TIPO DE QUADRO.

SLIP

ESCORREGAMENTO

ERRO RELACIONADO AO SINCRONISMO DO SISTEMA

VERIFICAR A CONFIGURAO DE SINCRONISMO DO EQUIPAMENTO DE TESTE. VERIFICAR O SINCRONISMO NO EQUIPAMENTO DE TRANSMISSO. VERIFICAR TAXA DE ERRO NO MEIO DE TRANSMISSO.