Welcome to our latest Earthing and Lightning Protection catalogue


We hope you will find your catalogue both informative and easy to use. We have included much more information within the tables and drawings to help you select the products you require. There are both new products and a wider selection of existing ranges included within this new catalogue. Many existing Wallis products have undergone design changes which have improved their mechanical performance and resistance to corrosion. Wallis Earthing and Lightning Protection materials supplied from our manufacturing facilities in Nottingham, UK are used on projects throughout the world. Hospitals in Kuwait, telecoms towers in Thailand, schools in Oman, railways in Hong Kong, towers in the UAE, petro chemical facilities in Malaysia and sub stations in Saudi Arabia all use Wallis Earthing and Lightning Protection. We are constantly working to improve our literature, so if you have any suggestions for us to improve this catalogue in the future, we would be pleased to hear from you.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

CONTENTS

Introduction

2-3 4-5 6-7 8-9 10 - 29 30 - 31 32 - 59 60 - 66 67 - 72 73 - 75

Product Locator

Alphabetical Product Index

Earthing Introduction

Earthing Product Pages

Lightning Protection Introduction

Lightning Protection Product Pages

Conductors

Other Products

Part Number Index

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

Welcome to Wallis

A commitment to excellent customer service also drives what we do. Part of this is ensuring that we maintain good stock levels so you can rely on same day despatch for many of our products. Orders received by 3.00pm can be despatched on the same day.

Founded 50 years ago, we have a long tradition of providing first class earthing and lightning protection equipment. What's more, we believe we have as wide a range of products as can be found in the industry.

We also deliver reassuring levels of quality. All our equipment is designed and manufactured to meet BS, European and International standards at our own facilities in Nottingham, UK, which include a foundry and machine shop.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

With extensive experience and technical expertise, we can also design and advise on lightning protection schemes to suit your individual requirements. We have designed and supplied materials for projects including high rise buildings, bridges, telecoms installations, towers and stadiums. Such is our reputation for high standards that Wallis equipment is used around the world, including the Middle East and Far East, with stocking distributors in key areas. If youve selected Wallis for structural lightning protection products, why not make us your choice for surge protection equipment too. Please ask for details.

AN Wallis - for quality products time after time.

Using This Catalogue


This catalogue is designed to be as easy to use as possible. To help find the product you need, there is an alphabetical index, part number index and product locator. Every product featured has its own technical and application drawings and product table. Materials specifications are also included. All measurements are shown in millimetres unless otherwise stated. Just phone, fax or e-mail us with your enquiries.
Application Example

Product Section

Product Name See Index Page

Dimensions

Product Illustration Part Number Full Index See Pages 73 & 74

Material Specification Finishes

Technical Drawing

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

PRODUCT LOCATOR

THIS ILLUSTRATION IS NOT INTENDED TO REPRESENT A LIGHTNING CONDUCTOR OR EARTHING SYSTEM CONFORMING TO ANY RELEVANT SPECIFICATION OR A STANDARD CODE OF PRACTICE

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

PRODUCT LOCATOR

KEY
1 2 3 4 5 6 7 8 9 10 11 12 13 Page Copper Tape 60 Aluminium Tape 64 PVC Covered Conductor 61 Solid Circular Conductor 65 Copper Stranded Conductor 66 PVC Covered/Insulated Conductor 61 Conductor Fixings 40 Strike Interception Plates 59 Junction Clamps for Tape 42 Bi-Metallic Connectors 44 Test/Junction Clamps for Tape 42 MV Clamp 50 Bonds 44, 45 14 15 16 17 18 19 20 21 22 23 24 25 Air Terminal Fixings Slate Holdfasts Air Terminals Earth Rods Earth Rod Clamps Earth Rod Clamps Inspection Pits Earth Plates/Lattice Mats Earth Rod Couplings Earth Bars/Disconnecting Links Flexible Braiding Bonds Earth Bonding Point Page 33 39 32 10-14 17 16 22-24 20 11-13 28 59 26

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

ALPHABETICAL PRODUCT INDEX


A
A Clamp 16 Adhesive Base Back 41 Adhesive DC Tape Clip 40 Adhesive Push In Clips 48 Air Rod Support 33-35, 47 Air Rods 32, 47 Air Terminal Base 33-35, 47 Air Terminal Saddles 47 Air Terminals and Fittings 32-36, 47 Aluminium Tape Plain Tape 64 PVC Covered 64 Anti Vandal Guard 56

D
DC Tape Clip 37 Denso Tape 57 Down Conductor Clip 37-38, 40, 48, 55 Driving Heads 11, 13, 15

E
E Clamp 18 Earth Bars 28 Earth Blocks 64 Earth Bonding Points 26 Earth Boss 27 Earth Mats 20 Earth Plates 20 Earth Points 26 Earth Points with Tails 26 Earth Rod Clamps Cable Clamp 17-19 GUV Clamps 18 Split Connector Clamp 19 Type A 16 Type G 17 U Bolt Clamps 18 Earth Rod Seals 25 Earth Rod To Cable Clamp 17 Earth Rod to Tape Clamp 16 Earth Rods Copperbond 10, 12 Solid Copper 14 Stainless Steel 14 Earthing Compounds Bentonite 21 Marconite 21 Eyebolt 27

B
B Bonds 44, 54 Back Plate Holdfast Stem 41 Bare Aluminium Conductor 64-65 Bare Copper Tape 60 Bare Solid Circular Conductor 65 Bare Stranded Copper Conductor 66 Bentonite 21 Bimetallic Connector Bi Metallic 44, 54 Stainless Steel 44, 54 Bonds B Bonds 44, 54 RWP Bonds 45, 51 Building in Holdfast 35

C
Cable to Tape Junction Clamp 46 Circular Bond Clamps - Double 53 Circular Bond Clamps - Single 53 Circular Cable Connector 65 Cleaning Solution 58 Compression Terminals 69 Concrete Inspection Pits 24 Conductive Cement 21 Conductor Aluminium Tape 64 Braid 64 Copper Tape 60 Lead Covered Copper 62 PVC Covered Aluminium 64-65 PVC Covered Copper 61 Solid Circular 8mm 65 Stranded Copper 66 Stranded Copper PVC Covered 66 Tinned Copper 62 Copper Earth Plates 20 Copper Lattice Mats 20 Copper Tape Green Yellow PVC Insulated 61 Lead Covered 62 LSF Covered 61 Plain Copper Tape 60 PVC Covered 61 Tinned 62 Copperbond Earth Rods 10 Corrugation Holdfast 39 Couplings 11, 13, 15

F
Fittings for Earth Rods 11, 13, 15 Flat Copper Tape 60-62 Flat Saddle 33 Flexible Copper Braid 64 Flexible Copper Braid Bond 59 Four Hole Earth Points 26

G
G Clamp 17 Glazing Bar Holdfast 38 Green Yellow PVC Insulated Copper Tape Ground Rods 10, 12, 14 GUV Clamps 18 61

H
Hard Drawn Copper Bar 63 Heavy Duty Cast Cable Saddle 49

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

ALPHABETICAL PRODUCT INDEX


I
Inspection Pits Concretev 24 Plastic Heavy Duty 22 Plastic Light Duty 23 Insulating Tape 61 Insulators 29 Interface Test Clamp 44, 46, 54 Internal Coupling Dowel 15

S
Screwdown Test Clamp 43 Screws 69, 71 Seal 25 Silfos 57 Single Hole Earth Points 26 Slate Holdfast 39, 49 Solder Solid Circular Conductor 65 Solid Copper Earth Plates 20 Solid Copper Earth Rods 14 Spike 15 Splitbolt Connectors 68 Square Conductor Clamp 50 Square Tape Clamps 42 Stainless Steel Earth Rods 14 Static Earth Bar Static Earth Receptacle 25 Straight Setscrew Cable Socket Stranded Copper Conductor Plain Copper 66 PVC Covered 66 Strike Interceptor Plates 59 Strike Pad 36

J
Jointing Clamp 42, 46, 50, 52 Junction Clamp 42-43, 46, 50, 52

L
Lattice Mats 20 Lead Covered Copper Tape 62 Light Duty Saddle 34 Lightweight Inspection Pits 23 LSOH Covered Copper Tape 61 Lugs 67

M
Marconite 21 Metalwork Bonding Clamp 51 Moisture Retaining Clay 21 Multi Point 36 MV Clamp 50

T
T Clamp 42, 50 T Connector 42, 50 Tape Clip Plastic 40 Gunmetal 37-38 Taper Pointed Air Rods 32 Tee Clamp 50 Test Clamp 42-43, 52 Threaded Copperbond Earth Rods Through Clamp 42, 52 Tinned Copper Tape 62 Tower Earth Clamp Two Hole Earth Points 26 Type H Splitbolts 68

N
Non Metallic DC Clips 40, 48 Non Metallic DC Tape Clip 40 Non Metallic DC with Plug 40 Non Metallic Slate Holdfasts 39

10

O
Oblong Test Clamp 42 One Hole Cable Clip 55 Oxide Inhibiting Compound 58

P
Pipe Bond 45, 51 Plastic Inspection Pits 22-23 Plate Type Test Clamp 43 Plugs 72 Puddle Flanges 56 Push in Plastic Cable Clip 48 Push In Roof Conductor Clip 48 PVC Covered Aluminium Tape 65 PVC Covered Copper Tape 61 PVC Covered Solid Circular Conductor 65 PVC Covered Stranded Copper Conductor 66

U
U Bolt Rod Clamps 18 Universal Cable Connector 46

V
Vandal Guards 56

W
Wall Plugs 72 Washers 70 Watermain Bond 45

R
Rainwater Pipe Bond 45, 51 Re Bar Clamp 3 Ridge Saddle 33 Rod Brackets 34 Rod to Cable Clamps 17-18 Rod to Cable Coupling Rod to Cable Lug Clamp Rod to Tape Clamp 16 Rod to Tape Coupling 35 RWP Bond 45, 51

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING - INTRODUCTION
A well designed earthing system is essential to ensure protection of personnel and equipment from danger associated with fault currents or lightning within buildings or areas falling within their zone of protection.

Earth terminations & networks


An earth electrode should be connected to each down conductor of a lightning protection system (LPS). Earth rods need an earth inspection housing for periodic testing of earth resistance. Earth rods are used in most applications and are driven into the ground as close as is practicable to the structure and the down conductor. They are normally spaced at specified intervals corresponding to the spacing on the down conductors.

Earthing system design considerations


To achieve an efficient earthing system it is essential that a low electrical resistance to earth is achieved, using good quality conductors with sufficient cross sectional area to carry the expected current flow. The conductors must also have a high corrosion resistance and must meet internationally recognised European and British earthing standards. The information contained in this section primarily refers to Lightning Protection Earthing Systems (LPS) and does not detail all earthing requirements for electrical wiring, although there are some similarities. Please refer to the IEE 16th edition wiring regulations for more details. Other factors to consider when designing an earthing system are: A survey is required to determine ground resistivity. Soil moisture content: more moisture always reduces soil resistance. Chemical composition of soil: certain salts and minerals affect soil resistivity. Temperature: if the ground is frozen its resistance becomes much higher. The extent of any buried services which could affect the earth termination networks. Details of metallic service pipes, rails, tanks etc. which may need bonding into the earth system to prevent the danger of side flashing. The area available to place earth electrodes, this may be limited.

Resistance to earth
For an LPS the earth termination network as a whole should have a combined resistance of not more than ten ohms, before bonding to building metalwork. However, the maximum resistance value for earthing systems is application specific. A single earth rod may not achieve the required resistance figure and several may be need to be fitted to achieve this; their combined resistance is proportional to the reciprocal of the individual rod resistances to earth. This rule holds true as long as each rod is situated outside the resistance area of any other. To ensure this is the case, it is generally accepted that the minimum spacing between rods should not be less than their driven length. The expected number of rods required to obtain a particular resistance value, e.g. ten ohms, can be roughly calculated. To do this the soil resistivity needs to be taken into consideration. A soil resistivity test will need to be performed. There are several methods used to obtain a lower resistance value: More rods can be driven. Rods can be driven deeper. Rods of a larger diameter can be used. Ring conductors connecting rods together underground can be used.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING - INTRODUCTION
Where deep driving is not possible shorter rods with a larger diameter can be used; copper earth mats and earth plates can be used in place of earth rods. A crows foot configuration can be used where parallel connection is not possible. Where high resistance soil conditions are a problem soil conditioning agents can be used to backfill rod holes. Conductive concrete can be used to backfill an earth mat. Both effectively increase an electrodes cross sectional area and therefore reduce its resistance to earth. The international standards also specify the recommended materials used for all earthing conductors and their dimensions. The information contained in this section is intended as a guide and should not be used to perform designs. A.N.Wallis does not accept responsibility for errors or omissions. Detailed information on earthing design is contained in internationally recognised European and British earthing standards. e.g. BS7430, BS7671.

Equipotential Bonding
It is common practice to use the buildings natural structural steelwork and bonding it to the LPS to further improve its ability to conduct lightning and fault currents to earth; prior permission may be required.

Joints
Joints should be mechanically effective, all joints other than welded ones are a potential discontinuity, and care should be taken to ensure contact surfaces are clean and that fixing clamps are tight and well protected from corrosion, which can occur if dissimilar metals are joined. Ideally there should be as few joints as possible in an earthing design.

Maintenance & life of an earth system


It is important to properly maintain an earth circuit to ensure it retains its ability to conduct the same current carrying capacity as it did when it was originally installed. Earth rod resistances should be regularly checked. Corrosion and fault currents can cause high resistance joints leading to overheating. However, if an earth system is correctly installed and maintained it should last for many years.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Earth Rods - Copperbond Threaded
Deep driven Wallis threaded copperbond earth rods are an economical method of achieving a low earth resistance.
1/2"12.7

The rods have a low carbon steel core, ideal for deep driving and a molecularly bonded copper covering of 99.9% pure copper to give lasting resistance to corrosion. The threads are formed by a rolling process to ensure strength and maintain the molecularly bonded copper along the full length of the threads.

5/8"14.2

The rods can be deep driven with power hammers or placed in a bore hole back filled with Marconite or Bentonite.
Thread Size L 1200
1/ " 2

L1 30 30 30 30 L1 30 30 30 30 30 30 L1 34 34 34 34 34 34

D 12.7 12.7 12.7 12.7 D 14.2 14.2 14.2 14.2 14.2 14.2 D 17.2 17.2 17.2 17.2 17.2 17.2

Weight 1.18 1.55 1.76 2.36 Weight 1.53 1.88 2.29 2.51 3.00 3.79 Weight 2.19 2.73 3.27 3.64 4.35 5.44

Pack Qty 5 5 5 5 Pack Qty 5 5 5 5 5 5 Pack Qty 5 5 5 5 5 5

Part Number ERB 412 ERB 415 ERB 418 ERB 424 Part Number ERB 112 ERB 115 ERB 118 ERB 120 ERB 124 ERB 130 Part Number ERB 212 ERB 215 ERB 218 ERB 220 ERB 224 ERB 230

1500 1800 2400

3/4"17.2

Thread Size

L 1200 1500 1800 2000 2400 3000

5/ " 8

Thread Size

L 1200 1500 1800 2000 2400 3000

3/ " 4

Driving Head
Ground Level Earth Pit Top Soil Conductor

Coupling and Driving Head, see page 11. Material: 99.9% pure electrolytic copper molecularly bonded onto a high tensile low carbon steel core minimum copper thickness 0.25mm.

Threaded Coupling

Rock

Sand

L1

Thread Size

Earth Rod
Shale

10

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Coupling for Threaded Copperbond Earth Rod
These Wallis couplings join lengths of threaded copperbond earth rods together. They facilitate deep driving and ensure continual contact between the rods, during and after driving. The coupling also protects the rod threads while using the driving stud. The coupling has a lead in for ease of assembly and a hex on the outside for grip and keeping the coupling tight when driving into the ground. Wallis couplings have a high copper content ensuring excellent acid and corrosion resistance.
Thread Size 1/2" 5/8" 3/4" L 68 69 79 D 19 19 24 D1 21 21 27 Weight 0.07 0.08 0.14 Pack Qty 25 25 25 Part Number ERBO 12 ERBO 16 ERBO 20
Driving Head

3/4" 5/8"

Earth Rod

Material: Aluminium Bronze.


D1
Threaded Coupling

D
Earth Rod

Earth Rod

Driving Head for Threaded Copperbond Earth Rod


These reusable Wallis driving heads are suitable for driving earth rods by hand or with a power hammer. The driving head screws into the coupling to allow deep driving of the earth rods and protect the threads.
Thread Size 1/2" 5/8" 3/4" L 50 54 62 D 19 22 25 Weight 0.07 0.08 0.13 Pack Qty 25 25 25 Part Number ERBD 12 ERBD 16 ERBD 20
5/8" 3/4"

Material: High Tensile Steel.


Driving Head

Thread Size D
Earth Rod

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

11

EARTHING
Earth Rod - Copperbond Unthreaded
9.5

Deep driven Wallis copperbond earth rods are an economical method of achieving a low earth resistance. The rods have a low carbon steel core, ideal for deep driving and a molecularly bonded copper covering of 99.9% pure copper to give lasting resistance to corrosion.

12.7

These rods have no threads and are joined together by using a taper fit coupling. The rods can be deep driven with power hammers or placed in a bore hole back filled with Marconite or Bentonite.
Diameter L 1200 L 1200 1500 Weight 0.61 Weight 1.53 1.88 2.29 2.51 3.00 3.79 Weight 1.53 1.88 2.29 2.51 3.00 3.79 Weight 2.19 2.73 3.27 3.64 4.35 5.44 Pack Qty 5 Pack Qty 5 5 5 5 5 5 Pack Qty 5 5 5 5 5 5 Pack Qty 5 5 5 5 5 5 Part Number ERB 012 Part Number ERB 612 ERB 615 ERB 618 ERB 620 ERB 624 ERB 630 Part Number ERB 712 ERB 715 ERB 718 ERB 720 ERB 724 ERB 730 Part Number ERB 812 ERB 815 ERB 818 ERB 820 ERB 824 ERB 830

14.2

9.5 Diameter

17.2

12.7

1800 2000 2400 3000

Diameter
1"

L 1200 1500

14.2

1800 2000 2400 3000

Diameter

L 1200 1500

17.2
Ground Level Earth Pit Top Soil Conductor

1800 2000 2400 3000

Driving Head

Coupling and Driving Head - see page 13.


Diameter L 3000 Weight 22.5 Pack Qty 5 Part Number ERB 930

Rock

1"

Material: 99.9% pure electrolytic copper molecularly bonded onto a high tensile low carbon steel core minimum copper thickness 0.25mm.
Earth Rod

Sand

Unthreaded Coupling
Diameter

Shale

12

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Coupling for Unthreaded Copperbond Earth Rod
These Wallis couplings join lengths of unthreaded copperbond earth rods together so that rods can be deep driven and ensure continual contact through the coupling, during driving and after driving. Wallis couplings have a high copper content ensuring excellent acid and corrosion resistance.
Rod Diameter 12.7 14.2 17.2 L 68 69 79 D 19 19 24 D1 21 21 27 Weight 0.07 0.08 0.14 Pack Qty 25 25 25 Part Number ERBO 06 ERBO 07 ERBO 08
14.2 17.2

Material: Aluminium Bronze.


Earth Rod

D1
Threaded Coupling

Earth Rod

Driving Head for Unthreaded Copperbond Earth Rod


These reusable Wallis driving heads are suitable for driving earth rods by hand or by power hammer.
Rod Diameter 12.7 14.2 17.2 L 90 100 110 D 22 22 22 Weight 0.19 0.22 0.22 Pack Qty 25 25 25 Part Number ERBD 06 ERBD 07 ERBD 08

Material: High Tensile Steel.

Driving Head
L

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

13

EARTHING
Earth Rod Solid Copper and Stainless Steel
15

Solid Copper Earth Rods


These rods are designed for use where extremely high corrosion resistance and exceptionally long life is required. The depth these Wallis rods can be driven to, depends on the soil conditions and rod thickness.

16

Where the solid copper rod is required to be driven deep the usual practice is to insert the rod into a bore hole and back fill with Marconite or Bentonite.
Diameter
20

L 1200 1500 1800 2400 3000 L 1200 1500

Weight 1.87 2.34 2.80 3.74 4.67 Weight 3.10 3.87 4.64 6.19 7.75

Pack Qty 5 5 5 5 5 Pack Qty 5 5 5 5 5

Part Number ERC 112 ERC 115 ERC 118 ERC 124 ERC 130 Part Number ERC 212 ERC 215 ERC 218 ERC 224 ERC 230

15 16 16 16 16 Diameter

16

20

1800 2400 3000

Coupling Dowel, Driving Head and Spike, see page 15. Material: 99.99% pure electrolytic copper, manufactured from hard drawn copper with purity and mechanical properties to BS 2874, C101 grade.

Stainless Steel Earth Rod


Ground Level Earth Pit Top Soil Conductor

Stainless steel Wallis earth rods are designed for use where problems may be caused by galvanic corrosion due to dissimilar metals such as a copper earth rod and buried metals being in close proximity.
Diameter 16 L 1200 Weight 1.87 Pack Qty 5 Part Number ERZ 112

Coupling, Driving Head and Spike, see page 15.


Rock

Material: Austenitic stainless steel to BS 970 Grade 316 S12.

Sand

Shale

14

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Driving Head for Solid Copper and Stainless Steel Earth Rods
The driving stud protects the thread and the top of the rod from damage when driving.
To Suit Rod Diameter 15, 16 20 L 39 42 D 14 19 Weight 0.04 0.06 Pack Qty 25 25 Part Number ERCD 16 ERCD 20
Driving Head

Material: Manufactured from Steel to BS970, grade 070M20.

Spike for Solid Copper and Stainless Steel Earth Rods


The steel spike enables the rod to be driven easily and stops the copper rod becoming damaged.
To Suit Rod Diameter 15, 16 20 L 42 55 D 14 19 Weight 0.04 0.08 Pack Qty 25 25 Part Number ERCS 16 ERCS 20

Spike

Material: Steel to BS 970 Grade 070 M20.


L L

Coupling Dowels for Solid Copper and Stainless Steel Earth Rods
This Wallis coupling dowel is used to join the solid copper or stainless steel rods. To suit Solid Copper Earth Rods
To Suit Rod Diameter 15, 16 and 20 L 39 Weight 0.02 Pack Qty 10 Part Number ERD 01
Coupling Dowel

To suit Stainless Steel Earth Rods


To Suit Rod Diameter 16 L 39 Weight 0.02 Pack Qty 10 Part Number ERD 16

Material: Steel to BS 970 Grade 070M20.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

15

EARTHING
Earth Rod to Tape A Clamps
ERA 1625 ERA 1625 SS

These clamps are used for joining the earth rod to various sizes of copper or aluminium tape. The clamps have a high resistance to corrosion and are mechanically strong to ensure a lasting connection. The aluminium clamps would mainly be used in lightning protection for connecting aluminium tape to a puddle flange in a lightning protection system.

ERA 2525

Nominal Rod Size 12.7 14.2 or 16 17.2


ERA 1631

Maximum Conductor 26 x 12 26 x 12 40 x 9 50 x 19 31 x 9 40 x 6 50 X 15 26 X 6

L 51 51 44 47 43 44 47 51

W 36 36 51 69 45 51 69 40

W1 18 18 22 21 18 22 21 25

Weight 0.15 0.15 0.25 0.25 0.20 0.25 0.25 0.20

Pack Qty 25 25 10 10 10 10 10 10

Part Number ERA 1625 ERA 1625 ERA 1638 ERA 1650 ERA 1631 ERA 1638 ERA 1650 ERA 2525

or 20 25

All complete with M10 x 25 bolt. Material: Clamp Body - Gunmetal or Aluminium Bronze. Bolt - Phosphor Bronze.
Nominal Rod Size 12.7 14.2 17.2 Maximum Conductor 26 x 12 26 x 12 26 x 9 L 40 40 40 W 36 36 36 W1 18 18 18 Weight 0.10 0.10 0.10 Pack Qty 25 25 25 Part Number ERA 1625 SS ERA 1625 SS ERA 1625 SS

Complete with M10 x 25 bolt.


ERA 1650

Material: Clamp Body - Gunmetal. Bolt - Stainless Steel.


Nominal Rod Size 14.2 17.2 Maximum Conductor 30 x 14 26 x 12 L 46 46 W 40 40 W1 19 19 Weight 0.12 0.12 Pack Qty 25 25 Part Number ERA 1625 A ERA 1625 A

ERA 1625A

Complete with M10 x 25 bolt. Material: Clamp Body - Aluminium. Bolt - Stainless Steel.

W1

W1

16

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Earth Rod to Cable Clamps
The Wallis rod to cable clamp has a high strength body with excellent resistance to corrosion. The clamp ensures a lasting and strong mechanical connection.
Nominal Rod Size Conductor Range mm2 6 - 35 6 - 35 16 - 70 35 - 95 L L1 W W1 W2 Bolt Weight Pack Qty Part Number
ERR 1035

9.5 14.2/16 14.2/16 17.2/20

31 44 41 48

20 21 30 36

20 24 21 30

15 15 18 19

12 18 17 21

M6 x 20 M10 x 20 M10 x 25 M10 x 25

0.03 0.03 0.08 0.10

25 25 25 25

ERR 1035 ERR 1635 ERR 1670 ERR 2095


ERR 1635

Material: Clamp Body ERR1035/ERR1635 Naval Brass. ERR1670/ERR2095 Gunmetal. Bolts ERR1035 - Stainless Steel. ERR1635 - Phosphor Bronze. ERR1670/ERR2095 Naval Brass.
ERR 1670

ERR 2095

W W2

L1

W1

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

17

EARTHING
U Bolt Connector Clamp
This versatile range of Wallis clamps can be used to connect tape and cable to the earth rod or a combination of both. The clamps have a U bolt connection onto a strong cast body providing a long lasting connection to the earth rod. Single Plate
Single Plate

Rod Dia Max 16 25 31 38 50

Conductor

L 60

W 33 33 38 34 39

Nut Size M8 M8 M10 M10 M10

Weight - Brass 0.16 0.18 0.40 0.30 0.57

Pack 10 10 10 25 20

Part Number Qty ERU 016 ERU 025 ERU 031 ERU 038 ERU 050

Tape or Cable

62 80 74 91

Double Plate
Rod Dia Max
Double Plate - Rod to Tape

Conductor 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3 16/70mm2 70/120mm2

L 61 61 68 75 96 39 68

W 33 32 38 35 38 39 39

Nut Size M8 M8 M8 M10 M10 M8 M8

Weight - Brass 0.42 0.24 0.37 0.42 0.83 0.24 0.29

Pack 25 10 25 10 10 10 10

Part Number Qty ERU 216 ERU 225 ERU 231 ERU 238 ERU 250 ERU 470 ERU 570

16 25 31 38 50 16 25

Double Plate - Rod to Cable

Material: Clamp Body - Gunmetal. U Bolt - Copper.

18

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Split Connector Clamp
These clamps are designed to be used with threaded and unthreaded rods. Suitable for connecting a cable lug to an earth rod. The clamp is supplied threaded or unthreaded.
Rod Size 9.5 5/8" 16 15 14.2 3/4" 20 Rod Type unthreaded threaded unthreaded unthreaded unthreaded threaded unthreaded L 31 52 42 42 42 50 50 W 18 26 25 25 25 29 28 D 20 25 32 32 25 28 29 Weight 0.08 0.22 0.24 0.24 0.23 0.31 0.28 Pack Qty 10 10 10 10 10 10 10 Part Number ERSO 10 ERSO 16 ERSS 16 ERC 26 ERC 24 ERSO 20 ERSS 20
ERS 016 ERC 24 ERSS 20

All complete with hexagon M12 x 50 bolt, except ERC 24 which has a wing nut. Material: Body - Gunmetal or Naval Brass. Bolt - Brass.

Disconnecting Link
The link is mainly used to offer a temporary break in the connection to earth allowing inspection and testing of an earth rod while disconnected from the lightning protection system network.
L 178 W 97 H 77 Weight 1.16 Pack Qty 1 Part Number EBC 001

Material: Mounting Bracket - Zinc Plated Steel. Insulators - Reinforced Polyester with Metal Inserts. Earth Bar - Copper.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

19

EARTHING
Earth Plate - Copper
These solid copper earth plates are used as part of an earthing network. They provide a long lasting solution where earth rods are unsuitable.
L 600 600 900 900 W 600 600 900 900 D 1.5 3 1.5 3 Surface Area 0.73m2 0.73m2 1.63m2 1.63m2 Weight 4.80 9.60 10.80 21.50 Pack Qty 1 1 1 1 Part Number EMP 601 EMP 603 EMP 901 EMP 903

Material: Pure electrolytic Copper Grade BS 2874-C101.

Lattice Copper Earth Mat


These Wallis lattice earth mats are a lower cost option to solid copper earth plates and when used with Bentonite provide a long lasting earth. Earth mats or plates may be preferred on some telecoms towers where step potential could cause problems.
L 600 900 900 W 600 900 900 D 3 3 3 Surface Area 0.31m2 0.65m2 0.65m2 Weight 4.50 9.50 6.10 Grid 5 7 5 Pack Qty 1 1 1 Part Number EML 603 EML 903 EML 903 SPC

Material: Copper Bar BS 1432-C101 with Copper Rivets.

20

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Earthing Compound - Marconite
Marconite forms a permanent solution when mixed with cement and is used when certain ground conditions make it difficult to obtain a reliable earth resistance or installations might require a low resistance. Marconite is used as a backfill to Wallis earth rods and plates. Marconite
Compound Marconite Pack Qty Bag 25Kg Part Number EMA 25

Mixing Ratio = 3 : 1 (Marconite : Cement).

Earthing Compound - Bentonite


Bentonite can be supplied in powder or granular form and is a moisture retaining clay which is used to reduce soil resistivity. Granular Its easier to handle in granular form, the powder can cause dust in windy conditions and blow away, granular is the preferred option for filling trenches where the conductor is covered with Bentonite and then water poured over and mixed in the trench. Powder Powder is the preferred method for pouring into bore holes to ensure the mixture is a thin enough consistency to reach the bottom of the bore hole, if diamond drilling is required for deep holes possibly 40mtrs and deeper and the Bentonite is to be pumped through the core into the hole powder would be the preferred option.
Compound Bentonite Granular Bentonite Powder Pack Qty Bag 25Kg Bag 25Kg Part Number EBG 25 EBG 25 P

Material: Sodium carbonate activated calcium montmorillonite clay. The product is a naturally occurring substance with no known ecological hazards and can be disposed of as non hazardous waste. Packaging Granular - Polypropylene Sacks. Powder - Paper Sacks.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

21

EARTHING
Earth Housing - Heavy Duty
This Wallis plastic earth housing will withstand loads up to 6,000 Kg and is suitable for most commercial and industrial applications. The pit is designed, shaped and sized to fit easily into brick paved walk ways. The lip of the pit makes a flush fit with standard sized bricks making the pit blend in with no requirement for a cement surround to the lid. The lid locks onto the base and can be opened with a standard blade screwdriver. The pit has three slots for earth bars.
L
EPP 001

H 216 216

W 258 258

W1 208 208

W2 245 245

W3 54 54

Lid Colour Black Grey

Weight 3.00 3.00

Pack Qty 1 1

Part Number EPP 001 EPP 002

309 309

Material: Base - Polypropylene. Lid - GRP. Earth Bars to suit - see page 29.

EPP 002

W1

W3

Three slots for earth bars shown on page 29.

W2

22

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Earth Housing - Light Duty
This Wallis earth housing is manufactured from high-grade heavy duty polypropylene for high strength and stress levels and has a maximum load of 2,000 Kg. UV stabilised against degradation by sunlight and non-brittle to prevent cold weather damage. This unique detachable easy locking lid allows easy inspection and ensures security of equipment as the locking mechanism can only be operated by the special key provided. Its lightweight feature allows easy handling, storage and transportation, thus increasing installation efficiency. Termination area is increased by 100% by simply locking two units together, allowing deeper earth electrode connections to be made and reducing the effects from harmful voltage gradients.
L 300 300 H 200 200 D 230 230 Lid Colour Black Grey Weight 1.50 1.50 Pack Qty 1 1 Part Number ERH 20 ERH 21
ERH 20

Material: Polypropylene Base and Lid.

ERH 21

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

23

EARTHING
Concrete Earth Housing
This Wallis concrete pit protects and makes available for inspection the earth rod connection. The pit can have an earth bar fitted diagonally across in slots provided for multiple connections.
L 310 L1 320 H 190 Weight 33.00 Pack Qty 1 Part Number ERH 01

Material: Concrete. Earth Bars to suit - see page 29.

Slots for earth bar

L1 H

24

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Earth Seal
The earth seal is fitted when the earth rod connection is below the water level and where there is a possibility of water entering the inspection pit from below ground, particularly useful when the earth electrode is being installed in a basement building. The seal is used in conjunction with the Wallis heavy duty earth housing shown on page 22.
D 355 H 440 Weight 1.59 Pack Qty 1 Part Number PES

Material: Plastic.

Static Earth Receptacle


These units are used in open areas or anywhere a temporary earthing point may be required such as airfields or petrol stations. The unit provides a static discharge point for aircraft, tankers, lorries or boats.
D 125 H 134 Weight 6.50 Pack Qty 1 Part Number ERX 05

Material: Gunmetal.

H D

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

25

EARTHING
Earth Bonding Points
These Wallis bonding points are installed to provide earthing continuity and a multiple bonding point. When cast into concrete they connect the re bar to the earthing or lightning protection system, the bonding points are available with one, two and four hole connections.
EGP 04

The bonding points are available with variety of tail lengths to suit different applications, specials can be manufactured to order. Bonding Point
No. of Holes
EGP 01

L 77 71 80

W 49 69 63

D 39 22 26

Weight 0.29 0.28 0.61

Pack Qty 10 10 10

Part Number EGP 01 EGP 02 EGP 04

1 2 4

EGP 02

Bonding point with Tail


No. of Holes 1 L 77 71 2 71 71 71 80 4 80 80 W 49 69 69 69 69 63 63 63 D 39 22 22 22 22 26 26 26 T 500 500 1000 1500 1500 500 1000 3000 Weight 0.77 0.74 1.09 1.42 2.41 0.92 1.31 1.56 Pack Qty 1 1 1 1 1 1 1 1 Part Number EGP 01 500 EGP 02 500 EGP 02 1000 EGP 02 1500 EGP 02 3000 EGP 04 500 EGP 04 1000 EGP 04 3000

EGP 04 1000

All tails are welded to the earth points. Material: Bonding Point - Gunmetal. Conductor - 70mm2 PVC Covered Copper Cable.

EGP 01 500

L W T W W

26

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Eye Bolt
This bolt provides a static earth point when attached to an earthing system. This Wallis unit is heavy duty and easily visible to anyone searching for the static discharge point.
Thread Size 5/8" L 134 W 29 Weight 0.62 Pack Qty 1 Part Number EYEBOLT

Material: Gunmetal.

Earth Boss
The earth boss is designed to provide an earth point on a steel structure. The boss is welded into place.
Hole Thread 10 L 50 W 50 Weight 0.77 Pack Qty 1 Part Number EPB 01

Material: Body - Mild Steel. Fittings - Stainless Steel.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

27

EARTHING
Earth Bars
Earth bars come in a variety of sizes and specification depending on individual requirements. Standard sizes are shown in the table with many other variations available and specials available to customer requirements. Standards
Terminations 4 4 6 6 8 8 10 10 12 12 14 14 6 L 350 475 450 575 550 675 650 775 750 875 850 975 650 W 97 97 97 97 97 97 97 97 97 97 97 97 99 H 70 70 70 70 70 70 70 70 70 70 70 70 70 No of Disc Links 0 1 0 1 0 1 0 1 0 1 0 1 2 Weight 2.24 2.85 3.47 4.27 4.64 5.68 5.78 7.12 6.96 8.52 8.12 9.94 4.90 Pack Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 Part Number EBC 004 EBC 104 EBC 006 EBC 106 EBC 008 EBC 108 EBC 010 EBC 110 EBC 012 EBC 112 EBC 014 EBC 114 EBC 206

Material: Hard Drawn Copper Bar - Grade C101 BS1432. Fitting - Brass, Phosphor Bronze or Stainless Steel. Channel Base - Mild Steel Zinc Plated. Insulators - Reinforced Polyester.

28

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

EARTHING
Earth Bars For Earth Housing
These earth bars fit into slots provided in the plastic and concrete earth housings where multiple connections are required to the earth rod. Available with five or seven hole connections. To suit ERH01.
L 300 W 31 D 6 6 Holes 5 7 Weight 0.49 0.50 Pack Qty 1 1 Part Number EBC 05 EBC 07
EBC 27 EBC 05

To suit ERH20 + ERH21.


L 250 W 31 D 6 6 Holes 5 7 Weight 0.42 0.39 Pack Qty 1 1 Part Number EBC 25 EBC 27

To suit EPP001 + EPP002.


L 203 W 25 D 6 6 Holes 5 7 Weight 0.24 0.22 Pack Qty 1 1 Part Number EBC 35 EBC 37

Material: Hard Drawn Copper Bar.

D W L

Insulators
These Wallis insulators are supplied with or without studs and locking nuts. Available for insulating conductors from each other or against a wall they offer a point of disconnecting to test the earthing system.
H W W1 35 35 Thread Size M10 M10 Weight 0.08 0.17 Pack Qty 10 10 Part Number EBI 001 EBI 002
EBI 001 EBI 002

40

46

Material: Reinforced Polyester with Metal Inserts. Threads and Nuts complete with EBI 002.

W H W1

Thread Size

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

29

LIGHTNING PROTECTION
Structural Lightning Protection
Introduction
If correctly installed, fitting a lightning protection system (LPS) will minimise the risk of damage to structures and injury to personnel by conducting high discharge currents safely to earth. Protection against the secondary effects of lightning to internal electrical equipment, known as transient over voltage protection is achieved by the use of transient over voltage protectors; this is in addition to the LPS. A LPS cannot protect against over voltage transients. Over voltage transient protectors cannot protect against direct lightning strikes. Both are required for total structural and equipment protection. termination; the zone of protection is used for buildings up to 20 metres; for buildings above this height the rolling sphere method is used.

Down conductors
The recommended spacing between down conductors varies according to risk and is detailed in internationally recognised European and British lightning protection standards. E.g., conductors may be spaced at 20 metres for some buildings but this distance could be reduced to 10 metres for tall or high risk buildings. Down conductors should be positioned as evenly as possible around the outside walls of the structure, starting from the corners. Minimum distances must be maintained to prevent side flashing. Re-entrant loops are also to be avoided.

Lightning protection strategy


The normal strategy in achieving protection is to capture the lightning at a preferred point by the use of air terminations and conducting it via low impedance down conductors and earth electrodes to a low resistance earth of less than ten ohms. Air terminations and down conductors are spaced at regular intervals to form a mesh of conductors around the perimeter of the building and roof, known as a Faraday cage, and are joined together by specially produced clamps and fixings or welding.

Earth terminations & networks


The information contained in this section primarily refers to Lightning Protection Earthing Systems (LPS) and does not detail all earthing requirements for electrical wiring, although there are some similarities. Please refer to the IEE 16th edition wiring regulations for more details. An earth electrode should be connected to each down conductor of a lightning protection system (LPS). Earth rods may need an earth inspection hosing for periodic testing of earth resistance. Earth rods are used in most applications and are driven into the ground as close as is practicable to the structure and the down conductor. They are normally spaced at specified intervals corresponding to the spacing on the down conductors.

Lightning protection system design considerations


A LPS is designed according to geographical location, local terrain, soil conditions size and height of building, type of material used in construction, type of material stored in the building, use of building and is based on established standards for risk assessment.

Resistance to earth
For an LPS the earth termination network as a whole should have a combined resistance of not more than ten ohms, before bonding to building metalwork. However, the maximum resistance value for earthing systems is application specific. A single earth rod may not achieve the required resistance

Air termination networks


The recommended spacing between conductors varies according to risk and is detailed in internationally recognised European and British lightning protection standards. E.g., a mesh of conductors of 10 by 20 metres is considered sufficient for most applications; however, a high risk structure may require a 10 by 10 mesh. There are two methods used to calculate the area immediately around a building protected by the air

30

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
figure and several may be need to be fitted to achieve this; their combined resistance is proportional to the reciprocal of the individual rod resistances to earth. This rule holds true as long as each rod is situated outside the resistance area of any other. To ensure this is the case, it is generally accepted that the minimum spacing between rods should not be less than their driven length. The expected number of rods required to obtain a particular resistance value, e.g. ten ohms, can be roughly calculated. To do this the soil resistivity needs to be taken into consideration. A soil resistivity test will need to be performed. There are several methods used to obtain a lower resistance value: More rods can be driven. Rods can be driven deeper. Rods of a larger diameter can be used. Ring conductors connecting rods together underground can be used. Where deep driving is not possible shorter rods with a larger diameter can be used; copper earth mats and earth plates can be used in place of earth rods. A crows foot configuration can be used where parallel connection is not possible. Where high resistance soil conditions are a problem soil conditioning agents can be used to backfill rod holes. Conductive concrete can be used to backfill an earth mat. Both effectively increase an electrodes cross sectional area and therefore reduce its resistance to earth. The international standards also specify the recommended materials used for all earthing conductors and their dimensions. be as few joints as possible in an LPS design.

Maintenance & life of a LPS


It is important to properly maintain a LPS to ensure it retains its ability to conduct the same current carrying capacity as it did when it was originally installed. Earth rod resistances should be regularly checked. Corrosion and fault currents can cause high resistance joints leading to overheating. However, if a LPS is correctly installed and maintained it should last for many years. The information contained in this section is intended as a guide and should not be used to perform designs. A.N.Wallis does not accept responsibility for errors or omissions. Detailed information on LPS design is contained in internationally recognised European and British LPS standards. e.g. BS6651.

Equipotential Bonding
It is common practice to use the buildings natural structural steelwork and bonding it to the LPS to further improve its ability to conduct lightning and fault currents to earth; prior permission may be required.

Joints
Joints should be mechanically effective, all joints other than welded ones are a potential discontinuity, and care should be taken to ensure contact surfaces are clean and that fixing clamps are tight and well protected from corrosion, which can occur if dissimilar metals are joined. Ideally there should

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

31

LIGHTNING PROTECTION
Taper Pointed Air Rods
These air rods are available in copper or aluminium and fit into the flat, ridge, light duty saddles or the side mounting brackets and coupling.
ATC 220

ATC 120M

Copper Air Rods


L 300 500 Thread Size L1 41 41 M16 41 41 41 41 3/4" 41 41 Weight 0.54 0.89 1.80 2.70 3.60 0.90 2.70 6.70 Pack Qty 5 5 5 5 5 5 5 5 Part Number ATC 112 M ATC 120 M ATC 139 M ATC 160 M ATC 179 M ATC 220 ATC 239 ATC 279

ATA 120

1000 1500 2000 500

ATA 112

1500 2000

Bases to suit air rods - see pages 33 and 34. Material: Copper. Aluminium Air Rods
L 300 500 1000 1500 2000 M16 Thread Size L1 41 41 41 41 41 Weight 0.16 0.32 0.64 0.96 1.09 Pack Qty 5 5 5 5 5 Part Number ATA 112 ATA120 ATA 139 ATA 160 ATA 179

Bases to suit air rods - see pages 33 and 34. Material: Aluminium.

L1

32

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Air Rod Fixings
Flat Saddle
Used in conjunction with an air rod, the flat saddle fixes onto the roof network of the lightning protection system connecting the tape to the air rod. The saddle is available threaded M16 or 3/4" to suit the air rod.
Thread Size M16 3/4" M16 Type Gunmetal Aluminium L 137 137 137 D 40 40 40 Weight 0.60 0.60 0.20 Pack Qty 5 5 5 Part Number ASGF 16 M ASGF 20 ASAF 16
ASAF 16 ASGF 16 M

Material: Gunmetal or Aluminium.

Thread Size

Air Rod Fixings


Ridge Saddle
These Wallis ridge saddles fix onto the roof network of the lightning protection system connecting the tape to the air rod. The saddle is available threaded M16 or 3/4" to suit the air rod.
Thread Size M16 3/4" M16 Type Gunmetal Aluminium L 137 137 137 D 34 34 34 Weight 0.70 0.60 0.20 Pack Qty 5 5 5 Part Number ASGR 16 M ASGR 20 ASAR 16
ASAR 16 ASGR 16 M

Material: Gunmetal or Aluminium.

L Thread Size

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

33

LIGHTNING PROTECTION
Air Rod Fixings
Light Duty Saddle
ASGL 16 M

This Wallis light duty saddle when used with an air rod, fixes onto the roof network of the lightning protection system connecting the tape to the air rod. The saddle is available threaded M16 or 5/8" or 3/4" to suit the air rods.
Thread Size M16 3/4" M16 Type Gunmetal Aluminium L 101 101 101 D 37 37 37 Weight 0.43 0.43 0.15 Pack Qty 5 5 5 Part Number ASGL 16 M ASGL 20 ASAL 16

ASAL 16

Material: Gunmetal or Aluminium.

L Thread Size

Air Rod Fixings


Side Mounting Brackets
These brackets provide a 75mm projection from the building face and are mainly used where it is not possible to fit a saddle on the roof so the air rod has to be fitted on the side of the building or chimney. The rod to tape coupling is used in conjunction with the side mounting brackets to secure the air terminal and connect to the tape.
Rod Diameter
AMBG 16 AMBA 16

Tape Type Gunmetal Aluminium

L 95 95 95

W 129 129 129

D 38 38 38

Weight 0.35 0.07 0.40

Pack Qty Part Number 5 5 5 AMBG 16 AMBG 20 AMBA 16

M16 3/4" M16

Material: Gunmetal or Aluminium.

W D

34

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Air Rod Fixings
Rod to Tape Coupling
Used with the side mounting brackets or the building in holdfast this Wallis unit screws onto the air rod and connects to the tape with the fixing screws provided.
Thread Size M16 3/4" M16 Type Gunmetal Gunmetal Aluminium L 80 80 80 D 39 39 39 Bolts Brass Brass S/Steel Weight 0.20 0.22 0.01 Pack Qty Part Number 5 5 5 AOG 16 M AOG 20 AOA 16
AOA 16 AOG 16 M

Material: Body Gunmetal or Aluminium.

Air Rod Fixings


Building in Rod Holdfast
These Wallis fittings are inserted into the concrete courses between the bricks and fix the air termination to the side of the building or chimney. This fixing method is mainly used where it is not possible to fit a saddle on the roof. The rod to tape coupling is used in conjunction with the building in holdfast to secure the air terminal and connect to the tape.
Rod Type M16 M16 Type Gunmetal Aluminium L 320 320 W 47 47 Weight 0.91 ? Pack Qty Part Number 5 5 ABHG 16 ABHA 16

Material: Gunmetal or Aluminium.

ABHG 16

L W W L

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

35

LIGHTNING PROTECTION
Multi Point
Used in conjunction with the copper air terminals the multi point is connected to the air termination network.
Rod Size M16 3/4" H 156 156 W 72 72 Weight 0.30 0.30 Pack Qty 5 5 Part Number MPC 16 MPC 16

MPC 16

Material: Body - Gunmetal. Spikes - Copper BS 2874 C1010.

Strike Pad
This Wallis strike pad is used where it is not possible or preferred not to have conductor on the roof or the side of a building.
SC 01

Typical application would be on the roof of a car park where the conductor is laid into the tarmac and strike pads fitted on top, or the side of a building where it is necessary to protect from side strikes but not possible to run conductor on the outside.
D
SA 01

H 40 40

Weight 0.53 0.15

Pack Qty 5 5

Part Number SC 01 SA 01

122 122

Complete with 4mm brass dowels and nut. Material: Copper or Aluminium.

36

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Metallic DC Tape Fixings
This metallic clip in gunmetal or aluminium secures the conductor to the building, the tape fits into the clip and is secured by two screws. The screws are flush in the 25 x 3 copper and aluminium versions, all the other sizes have screws standing proud. The clip has a hole in the base for fixing to the building with a screw and plug.
DGG 383 DCB 253

Tape Size 12 x 3 20 x 3 25 x 3 25 x 4 25 x 6 31 x 3 31 x 6 38 x 3 38 x 5 38 x 6 50 x 3 50 x 4 50 x 6 25 x 3 25 x 6 38 x 5 50 x 6 20 x 3 25 x 3 25 x 6 38 x 6 50 x 6 25 x 3 50 x 6

L 25 50 50 50 50 70 70 64 63 63 80 80 80 55 55 68 85 85 55 50 63 80 55 85

W 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20

H 10 10 10 10 13 13 13 10 13 13 10 10 16 13 16 16 13 10 10 13 13 16 23 20

Tape Type Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper PVC Covered Copper PVC Covered Copper PVC Covered Copper PVC Covered Copper Bare Aluminium Bare Aluminium Bare Aluminium Bare Aluminium Bare Aluminium PVC Covered Aluminium PVC Covered Aluminium

Weight 0.06 0.07 0.06 0.06 0.08 0.08 0.09 0.08 0.09 0.09 0.12 0.12 0.14 0.03 0.11 0.08 0.22 0.02 0.02 0.02 0.02 0.04 0.03 0.03

Pack Qty 25 25 25 25 25 25 25 25 25 25 15 15 15 25 25 25 15 25 25 25 25 15 25 15

Part Number DCG 123 DCB 203 DCB 253 DCG 254 DCG 256 DCG 313 DCG 316 DCG 383 DCG 385 DCG 386 DCG 503 DCG 504 DCB 506 DGP 253 DGP 256 DGP 385 DGP 506 DCA 203 DCA 253 DCA 256 DCA 386 DCA 506 DAP 253 DAP 506
DCB 506 DCG 386

Recommended fixing for the above are countersunk woodscrew 1 1/2" x No 10 and wall plug. Material: Body Gunmetal or Aluminium. Screws Brass or Stainless Steel.

L D W W

H L L

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

37

LIGHTNING PROTECTION
Tape Clips
These metal tape clips hold the tape flush to the surface and are fixed using two screws. Available to suit plain or PVC covered tape.
MTA 253

MPB 253

Tape Size 20 x 3 25 x 3 50 x 6

Tape Type bare bare bare PVC bare bare PVC

L 68 73 73 70 68 70 73

W 20 20 20 20 20 20 20

H 7 7 7 7 7 7 7

Weight 0.03 0.03 0.03 0.03 0.01 0.01 0.01

Pack Qty 50 50 50 50 50 50 50

Part Number MTB 203 MTB 253 MTB 506 MPB 253 MTA 203 MTA 253 MAP 253

MTB 253

25 x 3 20 x 3 25 x 3 25 x 3

Material: Copper or Aluminium.


L H

Glazing Bar Holdfast


These Wallis holdfasts were originally designed to be used on glazing units but can be used anywhere the conductor has to be fixed onto a narrow flange such as angle iron. The holdfast has a threaded hole on the back so that the metallic or non metallic DC clips can be attached.
HGG 253

Tape Type Copper Aluminium

H 35 35

L 20 20

W 13 13

Weight 0.12 0.04

Pack Qty 10 10

Part Number HGG 253 HGA 253

Material: Gunmetal.
HGA 253

38

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Corrugation Holdfast
The corrugation holdfast is used for attaching conductors to curved surfaces such as corrugated sheeting. The holdfast has a threaded hole on the back so that the metallic or non metallic DC clips can be attached. When this unit is fixed using the bolt provided, care should be taken to seal the hole using a compound such as Duxseal.
Tape Type Copper Aluminium L 39 39 W 39 39 Weight 0.11 0.11 Pack Qty 10 10 Part Number HCG 253 HCA 253
HCG 253

Material: Gunmetal or Aluminium.

Slate Holdfasts - to suit 25 x 3 Tape


This Wallis holdfast provides a method for fixing the tape above the roof tiles without drilling holes. The unit is made up from a soft aluminium tail attached to a non metallic DC clip. The aluminium tail slides under the roof tile and is fixed to the wooden beam with a nail, the clip then protrudes from the tile and offers a fixing for the tape. Other colours are available on customers request.
Tape Type Bare Bare PVC PVC L 310 310 310 310 W 48 48 48 48 H 13 13 13 13 Tail Length 290 290 290 290 Colour Brown Grey Brown Grey Weight 0.04 0.04 0.04 0.04 Pack Qty 50 50 50 50 Part Number HSAL 253 MB HSAL 253 GM HSAL 253 B HSAL 253 G
HSAL 253G HSAL 253BL

Material: Tail - Aluminium. Clip - Plastic.

W H

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

39

LIGHTNING PROTECTION
Non Metallic DC clips
This one piece clip with its integral hinged lid means there are no lost or dropped lids. The clips are available to suit both plain and PVC covered tape in a variety of sizes. These Wallis clips are manufactured in high grade polypropylene and UV stabilised to prevent degradation or breaking in cold weather.
NM 253 NP 253 BL

Conductor Size 20 x 3 25 x 3
NM 253 W

Tape Type Bare Copper Bare Copper Bare Copper PVC covered PVC covered PVC covered PVC covered PVC covered PVC covered

Colour

W 18 18 18 18 17 17 17 17 17 17 17

H 15 15 15 15 16 16 16 16 16 16 16

Dimensions Qty Per Part Number for Slot Pack 22 x 3 22 x 3 27 x 3 27 x 3 30 X 5 30 X 5 30 X 5 30 X 5 30 X 5 30 X 5 30 X 5 100 100 100 100 100 100 100 100 100 100 100 NM 203 B NM 203 G NM 253 B NM 253 G NM 506 B NP 253 B NP 253 G NP 253 S NP 253 W NP 253 BL NP 253 GR

Brown 48 48 50 Brown 50 Brown 48 Brown 48 Grey White Black 48 48 48 Stone 48

20 x 3 Bare Aluminium Grey 25 x 3 Bare Aluminium Grey 50 x 6 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3

Green 48

Weight: 0.07 Material: Polypropylene.


L W H W

Non Metallic DC Clips with Plug


These Wallis clips have an integral plug for ease of installation and an integral hinged lid. The clips are available to suit both plain and PVC covered tape in a variety of sizes. The clips are manufactured in high grade polypropylene and UV stabilised to prevent degradation or breaking in cold weather.
Conductor Size 20 x 3 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3 Tape Type Bare Copper Bare Copper PVC covered PVC covered PVC covered PVC covered PVC covered PVC covered Colour L W 17 17 17 17 18 18 18 18 18 18 H 16 16 16 16 16 16 16 16 16 16 Dimensions Qty Per Part Number for Slot Pack 22 x 3 22 x 3 27 x 3 27 x 3 30 X 5 30 X 5 30 X 5 30 X 5 30 X 5 30 X 5 100 100 100 100 100 100 100 100 100 100 NMP 203 B NMP 203 G NMP 253 B NMP 253 G NPP 253 B NPP 253 G NPP 253 S NPP 253 BL NPP 253 GR NPP 253 W

NPP 253 BL

NPP 253 B

Brown 48 48 48 50 50 50 Brown 48 Brown 50 Grey Black White Stone 50 Green 50

20 x 3 Bare Aluminium Grey


NMP 253 G

25 x 3 Bare Aluminium Grey

Weight: 0.07 Material: Polypropylene.


H W L W

40

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Adhesive Bases
The adhesive base is used where no mechanical fixing method is possible or allowed to attach the roof conductor network. The base itself has a threaded hole and is supplied with a fixing screw to suit the Wallis non metallic DC clips. When the base is glued in place the tape can be fixed into the clip attached to the base, the clip is not supplied with the base. The size of clip required depends on the conductor being installed. The base is fixed using the adhesive peel off strip and must be applied to a clean dust free surface.
Colour Brown Grey D 65 65 H 9 9 Weight 0.09 0.09 Qty Per Pack 100 100 Part Number NB01B NB01G
NB01B

NB01G

Material: Polypropylene.

D H

Back Plate Holdfast


This back plate holdfast is to be used where it is necessary to hold the conductor away from the building surface. The back plate holdfast has two holes in the base for fixing in place and a threaded hole with a fixing screw to attach the Wallis non metallic or metallic DC clip onto the holdfast.
L 74 W 63 Weight 0.33 Pack Qty 5 Part Number HBP

Material: Gunmetal.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

41

LIGHTNING PROTECTION
Square Junction Clamps
JA 253

These Wallis four way connectors are suitable for crossing over tapes, making straight through joints or T connections in a continuous network of tapes. The base has a countersunk hole in the middle for securing the clamp in place, the lid is secured by four screws. The screws are countersunk in the 25 x 3 versions, all the other clamps have proud headed screws.
Tape Size 25 x 3 25 x 6 31 x 3 38 x 6 50 x 3 Tape Type Copper Copper Copper Copper Copper Copper Lead Aluminium Aluminium Aluminium Aluminium L 50 50 60 70 77 79 67 50 50 70 77 Slot Size 26 x 3 26 x 3 32 x 3 39 x 5 51 x 3 51 x 5 27 x 5 26 x 3 26 x 3 39 x 5 51 x 5 Weight 0.15 0.25 0.22 0.59 0.50 0.52 0.86 0.07 0.07 0.09 0.09 Pack Qty 25 25 25 15 10 10 10 25 25 15 10 Part Number JG 253 JG 256 JG 313 JG 386 JG 503 JG 506 JPB 253 L JA 253 JA 256 JA 386 JA 506

JG253

JG 506

JPB 253L

50 x 6 25 x 3 25 x 3 25 x 6 38 x 6 50 x 6

Material: Gunmetal or Aluminium.


L

JGO 253

Oblong Junction Clamp


This oblong junction clamp is designed to join a range of tape sizes from 20 x 3 to 50 x 6. This Wallis clamp can also be used for disconnecting the earthing system for testing purposes. The clamp in many applications allows the conductors to be overlapped and secured by two bolts.
Conductor Tape Type
JGO 386

L 68 90 87 90 90 68 90

W 40 45 44 63 45 40 63

H 19 24 24 26 24 19 26

Slot Size Weight Pack Qty Part Number 28 X 11 36 X 15 40 x 15 52 x 15 35 x 15 28 X 18 52 x 15 0.34 0.35 0.35 0.58 0.34 0.11 0.15 10 10 10 10 10 10 10 JGO 253 JGO 316 JGO 386 JGO 506 JPBO 253 L JAO 253 JAO 506

25 X 3 31 X 6 38 X 6 50 X 6 25 X 3 25 X 3 50 X 6

Copper Copper Copper Copper Lead Aluminium Aluminium

JGO 506

Material: Gunmetal or Aluminium.


H L W

42

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Plate Type Test Clamp
This Wallis clamp is used to form a disconnecting joint between the down conductor system and the earthing system. The conductors are secured by four bolts attached to the base, the clamp is also suitable for use in heavy duty applications where the conductors up to 50x6 have to be joined in a crossover or T connection.
Tape Size 25 x 3 25 x 3 Type Gunmetal Aluminium D 70 70 Weight 0.37 0.08 Pack Qty 5 5 Part Number JPG 253 JPA 253
JPA 253

Material: Gunmetal or Aluminium.


JPG 253

Screw Down Test Clamp


The screwdown test clamp allows easy access to copper conductors where frequent inspection or testing may be necessary, the heavy duty lid simply screws on and off the base, the clamp is manufactured in gunmetal and suitable for copper based conductors only. Because this Wallis clamp is so simple to unassemble it should not be used at ground level or anywhere within easy reach of the public.
Tape Size 25 x 3 D 61 H 61 H 61 Weight 0.72 Pack Qty 5 Part Number JSG 253

Material: Gunmetal.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

43

LIGHTNING PROTECTION
Bi Metallic Connectors
These fittings are used to connect aluminium tape to copper tape. They are a neat and practical jointing method without the need for tinning, riveting or wrapping the joint. It is recommended to use an oxide inhibiting compound with this connector (on page 58). The unit is fixed to the wall and the conductors then fixed to the connector.
Tape Size
BSS 253

L 98 76

W 29 21

H 25 20

Bolt M10 x 25 M10 x 10

Weight 0.20 0.16

Pack Qty 10 10

Part Number BIM 253 BSS 253

25 x 3 25 x 3
BIM 253

Material: Aluminium and Copper or Stainless Steel.

B Bonds
This Wallis bond is used for bonding copper or aluminium tapes to flat metal surfaces.
Tape
BBA 253

L 35 35 33

H 10 10 10

Bolt M10 x 25 M10 x 35 M8 x 35

Weight 0.04 0.03 0.01

Pack Qty Part Number 10 10 10 BBG 253 BBG 253SS BBA 253

25 x 3 Copper 25 x 3 Copper 25 x 3 Aluminium

Material: Body: Aluminium or Gunmetal. Bolt for BBG 253 SS and BBA 253 in Stainless Steel. Bolt for BBG 253 Phosphor Bronze .
BBG 253 BBG 253 SS

44

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Rainwater Pipe Bond
This pipe bond can be used on any applications where the tape can be wrapped around circular objects such as pipes or rails.
Tape 25 x 3 Type Copper L 32 W 32 32 H 16 16 Bolt M10 x 40 M10 x 40 Weight Pack Qty Part Number 0.20 0.09 10 10 BRG 253 BRA 253
BRG 253

25 x 3 Aluminium 32

Material: Body Gunmetal or Aluminium. Bolt Stainless Steel.

BRA 253

Watermain Pipe Bond


This Wallis bond is designed to bond metallic pipes into the earthing or lightning protection system.
Tape 25 x 3 Copper L 45 W 36 Bolt M10 x 35 Weight 0.21 Pack Qty 10 Part Number BWG253

Material: Gunmetal.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

45

LIGHTNING PROTECTION
Cable to Tape Joint
JOM 253

These Wallis four way connectors are suitable for crossing over tapes and cable, making straight through joints or T connections in a continuous network.
To Suit
JOA 253

Conductor

Tape

W 52 52

H 14 14

Weight Qty 0.28 0.09

Pack 10 10

Part Number JOM 253 JOA 253

Copper

8 diameter or 50 sqm 25 X 3

Aluminium 8 diameter or 50 sqm 25 X 3

Material: Gunmetal or Aluminium.

H W

Universal Cable Connector


This connector is suitable for joining cables in a test point as part of the lightning protection system. Three sizes cover a range of cables from 70 - 120sq mm.
Conductor Size 70 sq mm 95 sq mm 120 sq mm L 71 71 71 W 21 21 21 H 19 19 19 Weight 0.15 0.17 0.19 Pack Qty 10 10 10 Part Number UC 070 UC 095 UC 120

Material: Naval Brass.

46

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Air Rods
These air rods are used as part of a lightning protection system designed in 10mm diameter conductor. Supplied in copper or aluminium they fit into the air terminal saddle.
Thread Dia 10 10 10 10 L 500 1000 500 1000 To Suit Copper Copper Aluminium Aluminium Weight 0.35 0.70 0.11 0.22 Pack Qty 5 5 5 5 Part Number ARC 102 ARC 105 ARA 102 ARA 105
ARC 102

Supplied with lock nut. Material: Hard Drawn Copper or Aluminium.

ARA 102

THREAD SIZE

Air Terminal Saddle


This Wallis air terminal saddle can be installed vertically for walls and parapets or horizontally for roof mounting. The fitting is designed to be used with the air rods shown above.
Thread Dia mm 10 10 10 10 Fitting Horizontal Horizontal Vertical Vertical L 62 62 62 62 W 47 47 47 47 Conductor Dia mm 8 8 8 8 To Suit Copper Copper Weight Pack Qty 0.35 0.35 5 5 5 5 Part Number UAG 08 UAA 08 UAG 08V UAA 08V

UAA 08V

Aluminium 0.08 Aluminium 0.08

UAG 08

Complete with M10x25 stainless steel or M10x25 phosphor bronze hexagon bolt. Material: Gunmetal or Aluminium.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

47

LIGHTNING PROTECTION
Down Conductor Clip
A one piece fold over clip designed for ease of installation to suit 8mm bare and PVC covered conductor. These Wallis clips are manufactured in high grade polypropylene and UV stabilised to prevent degradation or breaking in cold weather.
Conductor Dia 8 8 8 8 8 8
CP 08 S

Colour Grey Brown Brown Grey Black White Stone

Conductor Bare Bare PVC PVC PVC PVC PVC

L 34 34 34 34 34 34 34

W 23 23 23 23 23 23 23

H 33 33 33 33 33 33 33

CP 08 BL

CM 08 B

Pack Qty 100 100 100 100 100 100 100

Part Number CM 08 G CM 08 B CP 08 B CP 08 G CP 08 BL CP 08 W CP 08 S

Weight: 0.0001 Material: Polypropylene.


L

H W

RM 08 B

Push in Roof Conductor Clip


A one piece single screw fixing clip designed for ease of installation to suit 8mm bare and PVC covered conductor. These clips are manufactured in high grade polypropylene and UV stabilised to prevent degradation or breaking in cold weather.
Conductor Dia
RP 08 G

Colour Conductor Grey Brown Brown Grey Black White Stone Bare Bare PVC PVC PVC PVC PVC

L 29 29 29 29 29 29 29

W 18 18 18 18 18 18 18

H 14 14 14 14 14 14 14

Pack Qty 100 100 100 100 100 100 100

Part Number RM 08 B RM 08 G RP 08 B RP 08 G RP 08 BL RP 08 W RP 08 S

8 8 8
RP 08 W

8 8 8 8

Weight: 0.0001 Material: Polypropylene.


W

48

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
8mm DC Clip
This adaptable clip can be used as a support for the 10mm dia air rod or as a heavy duty DC clip to suit 8mm bare and PVC covered conductor.
DCG 810

Conductor Dia 8 8 8 8

Conductor Bare Copper PVC Copper Bare Aluminium PVC Aluminium

L 48 48 48 48

W 17 17 17 17

H 20 20 20 20

Weight 0.06 0.06 0.03 0.03

Pack Qty 25 25 25 25

Part Number DCG 810 DCG 815 DCA 810 DCA 815
DCG 815

Material: Aluminium or Gunmetal.

Slate Holdfast
This Wallis holdfast provides a method for fixing 8mm bare conductor above the roof tiles without drilling holes. The unit is made up from a soft aluminium or copper tail attached to a push in roof conductor clip. The aluminium tail slides under the roof tile and is fixed to the wooden beam with a nail, the clip then protrudes from the tile and offers a fixing for the conductor. All coloured clips available on customer request.
Conductor Dia 8 8 Colour Brown Grey L W H 14 14 Clip Colour Brown Grey Weight 0.01 0.01 Pack Qty 50 50 Part Number HC 08 B HA 08 G

HC 08 B

320 18 320 18

Material: Tail Aluminium or Copper. Clip Polypropylene.

W H

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

49

LIGHTNING PROTECTION
MV Clamp
These Wallis four way connectors are suitable for crossing over 8mm conductor, making straight through joints or T connections in a continuous network of conductor. The lid is secured by a single bolt for ease of installation.
Dia mm 8 8
MVA 08

MVG 08

Conductor Copper Aluminium

L 40 40

H 18 18

Weight 0.05 0.01

Pack Qty 10 10

Part Number MVG 08 MVA 08

Material: Copper or Aluminium.

T Connector
TCG 08

This purpose designed T connector for 8mm conductor is ideal for connecting the lightning protection roof network to the down conductors. Secured by a M10 bolt and nut.
Dia mm 8 8 Conductor Copper Aluminium L 45 44 W 45 25 H 19 20 Weight 0.11 0.06 Pack Qty 10 10 Part Number TCG 08 TCA 08

TCA 08

Material: Gunmetal or Aluminium.

50

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Metalwork Bonding Clamp
This one piece clamp is designed for bonding 8mm conductor to steel construction or surfaces. The bond is secured by drilling two holes in the steelwork and bolting or welding the clamp in place, the conductor is then fixed to the clamp.
Conductor Dia 8 8 Conductor Copper L 82 W 40 40 H 25 25 Bolt M10 x 25 M10 x 30 Weight Pack Qty Part Number 0.14 0.09 10 10 MBG 08 MBA 08

Aluminium 82

Material: Aluminium or Copper.

MGB 08

MBA 08

L H

Rainwater Pipe Bond


This pipe bond can be used on any application where the perforated tape can be wrapped around circular objects such as pipes or rails. This Wallis bond suits 8mm conductor.
Conductor Conductor Dia 8 8 Copper L 55 W 32 31 D 17 16 Bolt M8 x 40 M10 x 35 Weight 0.37 0.09 Pack Qty Part Number 5 5 BRG 08 BRA 08

Aluminium 51

Material: Aluminium or Gunmetal.

BRG 08

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

51

LIGHTNING PROTECTION
Test or Through Clamp
This test or through clamp is designed to join a 8mm circular conductor. This Wallis clamp can also be used for disconnecting the earthing system for testing purposes.
Conductor Dia 8 8 Conductor Copper L 64 W 22 22 H 17 17 Bolt M10 x 20 M10 x 20 Weight Pack Qty Part Number 0.17 0.06 25 25 JTG 08 JTA 08

JTG 08 JTA 08

Aluminium 64

Material: Body Gunmetal or Aluminium. Screw Phosphor Bronze & Stainless Steel.

W L

Interface Test Clamp


For connecting 25x3 tape to 8mm conductor. This Wallis clamp is most commonly used where the lightning protection system has been designed in 8mm circular conductor and the connection to the earth rod is by 25x3 copper tape, the most economical way to change over is to install this clamp as the test point.
Conductor Conductor Dia 8
JYG 08

L 70

W 34 34

D 15 15

Bolt M10 x 16 M10 x 16

Weight 0.25 0.09

Pack Qty Part Number 25 25 JYG 08 JYA 08

Copper

Aluminium 70

JYA 08

Material: Aluminium or Gunmetal.

W L

52

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Circular Bond Clamp
This single plate clamp is suitable for bonding copper conductor to steel surfaces in area where the clamp is protected or unlikely to suffer damage. Two versions of this Wallis clamp will accommodate conductors up to 70sq mm and 120sq mm. The clamp is fixed by drilling a hole in the steelwork and securing with the bolt provided.
BTC 016 BTC 070

Conductor 8mm or 16 / 70sq mm 70 / 120sq mm

L 40 40

W 22 36

H 12 15

Bolt Size M10 x 50 M12 x 60

Weight 0.09 0.15

Pack Qty 10 10

Part Number BTC 016 BTC 070

Material: Gunmetal.

H L

Circular Bond Double Plate


This Wallis double plate clamp is suitable for bonding copper conductor to steel surfaces in area where a more robust version of the single plate is required such as where cladding may be installed later or the complete clamp will be covered by concrete. Two versions of this Wallis clamp will accommodate conductors up to 70sq mm and 120sq mm. The double plate clamp is fixed by drilling a hole in the steelwork and securing with the bolt provided.
Conductor 8mm or 16 / 70sq mm 70 / 120sq mm L 45 48 W 30 35 H 17 22 Bolt M10 x 50 M10 x 16 Weight 0.12 0.23 Pack Qty 10 10 Part Number
BTC 216 BTC 270

BTC 216 BTC 270

Material: Gunmetal.
W

D L

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

53

LIGHTNING PROTECTION
Circular B Bond
BBG 08 BBA 06

This Wallis bond is used for bonding copper or aluminium 8mm conductor to flat metal surfaces.
Conductor Dia 8 8 Conductor Copper Aluminium L 52 52 W 33 33 D 18 18 Weight Qty 0.14 0.09 Pack 10 10 Part Number BBG 08 BBA 08

Material: Body - Gunmetal or Aluminium. Screw - Stainless Steel & Phosphor Bronze.

W L D

Bi Metallic / Test Clamp


BIM 25308

These fittings are used to connect an 8mm circular aluminium down conductor to copper, the clamp can also be used as a test point. This is a neat and practical jointing method without the need for tinning riveting or wrapping the joint. It is recommended to use an oxide inhibiting compound with this connector. The unit is fixed to the wall and the conductors then fixed to the connector.

BIM 08

Conductor Dia 8 8 8 to 25 x 3

L 78 71 78

W 28 22 28

D 28 19 28

Weight 0.25 0.09 0.20

Pack 10 10 10

Part Number Qty BIM 08 BSS 08 BIM 253 08

Material: Body BIM 08 and BIM 253 08 Copper and Aluminium, BSS 08 Stainless Steel. Screw Phosphor, Bronze & Stainless Steel.

D W

54

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
One Hole Cable Clip
This simple clip can be used for fixing conductors 50-95sq mm.
Conductor Size 8 50sq mm 8 PVC/70sq mm 95sq mm 8 8 PVC Conductor Copper Copper Copper Copper Aluminium Aluminium Weight 0.01 0.01 0.01 0.01 0.01 0.01 Pack Qty 50 50 50 50 50 50 Part Number PCC 001 PCC 002 PCC 003 PCC 004 PCA 001 PCA 002
PCC 001

Material: Copper or Aluminium.

Static Earth Bar


Manufactured from phosphor bronze rod with gunmetal fixing plates this wall mounted bracket when connected provides a permanent point where anybody requiring a temporary earth can clip on.
L 350 H 104 Weight 1.52 Pack Qty 1 Part Number ERY 10

Material: Gunmetal and Phosphor Bronze rod.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

55

LIGHTNING PROTECTION
Anti Vandal Guard
This Wallis anti vandal guard shields 8mm or 25 x 3 copper down conductor and protects from accidental damage or vandals. Easy to secure the guard has a low profile and the galvanised finish gives a long lasting resistance to corrosion.
L 2 mtr 3 mtr Fitting 25 x 3 25 x 3 W 72 72 H 17 17 Weight 1.98 2.72 Pack Qty 1 1 Part Number AVG AVG 3

Material: Mild Steel Galvanised.

Puddle Flange
The puddle flange is used where the down conductors or roof terminations must pass through a waterproof membrane. The flats of the flange enable the flange to be made waterproof by fixing with glue, concrete or specialist roofing materials.
Conductor Copper Aluminium L 600 600 W 150 150 Weight 1.68 0.54 Pack Qty 1 1 Part Number PFC 01 PFA 01

Material: Aluminium or Copper.

For aluminium and copper clamps, see page 16.

56

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Denso Tape
A waterproof tape for wrapping joints to provide protection against corrosion.
Size mm 50 Coil Size Metres 10 Pack Qty 1 Part Number DT 510

Silfos
This allows the installer to braze copper to copper in air without the use of flux.
Size mm 50 Coil Size Metres 8 Thickness mm 0.12 Pack Qty 1 Part Number Silfos

Material: Alloy of Silver, Phosphorous and Copper.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

57

LIGHTNING PROTECTION
Oxide Inhibiting Compound
Electrical joint compound, recommended for use on aluminium to aluminium and aluminium to copper connections, on all bare conductors and bus bars. This assures a high conductivity joint by sealing out air and moisture to prevent corrosion and reformation of oxide film.
Size 8 oz Container tube Pack Qty 1 Part Number IC 08

Bitumen Felt
Supplied in rolls or cut to form a felt pad are used on asphalt roofs.
L 10 mtrs 100 W 100 100 Weight 2.64 0.03 Pack Qty 1 1 Part Number BFR 01 BFB

Part number BFB is a square pad.

58

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Flexible Braid Bond
This Wallis bond is used for bonding metal doors, gates, fences etc. Other lengths and sizes can be manufactured to customer requirements.
Bond Width 25 x 3.5 25 x 3.5 25 x 3.5 L 200 300 400 To Suit Bolt M10 M10 M10 Weight 0.04 0.07 0.11 Pack Qty 10 10 10 Part Number BFE 200 BFE 300 BFE 400
BFE 400

Material: Copper - BS4109 C101.

BFE 300

BFE 200

Bond Width

Strike/Interceptor Plate
These Wallis plates fit under the roof tile and are connected into the lightning protection system, the square strike pad protrudes from the tile.
Conductor Copper Aluminium L 550 500 D 50 50 Weight 0.32 0.05 Pack Qty 5 5 Part Number SPC SPA
SPC

Material: Copper or Aluminium.

SPA

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

59

CONDUCTORS
Bare Copper Tape
Wallis bare copper tape is used on both lightning protection and earthing applications. The copper is manufactured to BS1432 C101/C103. The copper tape is annealed for ease of use with radiused edges and marked Wallis UK.
TC 506

The KA rating is based on recommendations of BS7430 with an initial temperature of 30C and a maximum of 250C.
Size mm2 18.75 37.50 30.00 60.00 37.50 75.00 100.00 150.00 60.00 90.00 120.00 150.00 93.00 186.00 126.00 114.00 190.00 228.00 120.00 160.00 200.00 240.00 150.00 200.00 250.00 300.00 KA Rating KA Rating Weight 1 Second 3 Seconds per Mtr Kg 3.3 6.6 5.3 10.6 6.6 13.2 17.6 26.4 10.6 15.8 21.2 26.4 16.3 32.7 22.1 20.0 33.4 40.1 21.1 28.1 35.2 42.2 26.4 35.2 44.0 52.8 1.9 3.8 3.0 6.1 3.8 7.6 10.2 15.2 6.1 9.1 12.2 15.2 9.4 18.9 12.8 11.6 19.3 23.2 12.2 16.3 20.3 24.4 15.2 20.3 25.4 30.5 0.17 0.33 0.27 0.53 0.33 0.67 0.89 1.33 0.53 0.80 1.07 1.33 0.83 1.65 1.13 1.01 1.69 1.45 1.06 2.03 1.78 2.16 1.33 1.78 2.22 2.68 Coil Size Mtr 100 100 100 100 100 50 50 40 50 50 40 40 50 30 40 50 30 25 40 30 25 25 40 30 20 20 Part Number TC 121 TC 123 TC 201 TC 203 TC 251 TC 253 TC 254 TC 256 TC 302 TC 303 TC 304 TC 305 TC 313 TC 316 TC 3154 TC 383 TC 385 TC 386 TC 403 TC 404 TC 405 TC 406 TC 503 TC 504 TC 505 TC 506

TC 406

12.5 X 1.5 12.5 X 3 20 x 1.5 20 x 3 25 x 1.5 25 x 3 25 x 4

TC 303

TC 256

25 x 6 30 x 2 30 x 3 30 x 4 30 x 5 31 x 3 31 x 6

TC 253

TC 203

31.5 x 4 38 x 3 38 x 5 38 x 6 40 x 3 40 x 4 40 x 5 40 x 6 50 x 3 50 x 4 50 x 5 50 x 6

Material: Copper - BS1432 C101/C103.

Size

60

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

CONDUCTORS
PVC Covered Copper Tape
The PVC covered copper tape is used mainly for running, as a down conductor on a lightning protection system, the PVC covering is used for aesthetic purposes to blend the down conductor into the building. The copper tape is annealed for ease of use. The PVC covering is 1mm thick PVC, colours to BS5252, Green to BS746C.
Colour Size mm2 KA Rating KA Rating 1 Second 3 Seconds 3.3 13.2 10.6 13.2 26.4 52.8 13.2 26.4 13.2 52.8 13.2 26.4 13.2 1.9 7.6 6.1 7.6 15.2 30.5 7.6 15.2 7.6 30.5 7.6 15.2 7.6 Weight Coil Size Part Number Per Mtr Mtr 0.21 0.77 0.61 0.77 1.53 2.95 0.77 1.33 0.77 2.95 0.77 1.53 0.77 140 50 27 50 40 20 50 40 50 20 50 40 50 TP 121 BL TP 253 BL TP 203 GR TP 253 GR TP 256 GR TP 506 GR TP 253 W TP 256 W TP 253 S TP 506 S TP 253 B TP 256 B TP 253 G
TP 506 S TP 253 GR TP 253 BL

Black 12.5 x 1.5 18.75 25 x 3 Green 20 x 3 25 x 3 25 x 6 White Stone Brown Grey 25 x 3 25 x 6 25 x 3 25 x 3 25 x 6 25 x 3 75.00 60.00 75.00 150.00 75.00 150.00 75.00 75.00 150.00 75.00

50 x 6 300.00

50 x 6 300.00

High conductivity annealed copper tape manufactured in accordance with BS1432 C101/C103. LSF (Low Smoke and Fume) - PVC Covered
Colour Size mm2 KA Rating KA Rating Weight Coil Size 1 Second 3 Seconds Per Mtr Mtr 3.3 13.2 10.6 13.2 26.4 33.4 1.9 7.6 6.1 7.6 15.2 19.3 0.21 0.77 0.61 0.77 1.53 0.77 140 50 40 20 50 50 Part Number TP 121 BLLSF TP 253 GRLSF TP 203 GRLSF TP 253 GRLSF TP 256 GRLSF TP 385 WLSF
TP 253 G TP 253 B TP 253 GY

Black 12.5 x 1.5 18.75 25 x 3 Green 20 x 3 25 x 3 25 x 6 38 x 5 75.00 60.00 75.00 150.00 190.00

High conductivity annealed copper tape manufactured in accordance with BS1432 C101/C103. Green Yellow PVC Insulated Copper Tape
Size 25 x 3 25 x 6 mm2 75 150 KA Rating KA Rating 1 Second 3 Seconds 13.2 26.4 7.6 15.2 Weight Per Mtr 0.79 1.53 Coil Size Mtr 50 40 Part Number TP 253 GY TP 256 GY

TP 253 W

PVC colour to BS6746C.

Size

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

61

CONDUCTORS
Tinned Copper Tape
High conductivity annealed copper tape manufactured in accordance with BS1432 C101/C103.
Size
TT 506

mm2 18.75 37.50 60.00 37.50 75.00 100.00 150.00 60.00 93.00 114.00 190.00 160.00 240.00 150.00 300.00

KA Rating KA Rating 1 Second 3 Seconds 3.3 6.6 10.6 6.6 13.2 17.6 26.4 10.6 16.4 20.1 33.4 28.2 42.2 26.4 52.8 1.9 3.8 6.1 3.8 7.6 10.2 15.2 6.1 9.5 11.6 19.3 16.3 24.4 15.2 30.5

Weight Per Mtr 0.17 0.33 0.54 0.33 0.67 0.90 1.33 0.53 0.83 1.03 1.69 1.44 2.16 1.35 2.68

Coil Size Mtr 140 100 50 50 50 50 40 50 50 50 30 40 25 40 20

Part Number TT 121 TT 123 TT 203 TT 251 TT 253 TT 254 TT 256 TT 302 TT 313 TT 383 TT 385 TT 404 TT 406 TT 503 TT 506

12 x 1.5 12 x 3 20 x 3 25 x 1.5 25 x 3 25 x 4 25 x 6 30 x 2

TT 406

TT 313

31 x 3 38 x 3 38 x 5 40 x 4 40 x 6 50 x 3 50 x 6

TT 256

TT 253

Tinned PVC Covered Copper Tape


Colour
TT 203

Size 25 x 3 25 x 3 25 x 6 25 x 3 25 x 6 25 x 3 25 x 3 25 x 6 25 x 3 25 x 6

mm2 75.00 75.00 150.00 75.00 150.00 75.00 75.00 150.00 75.00 150.00

KA Rating KA Rating Weight Coil Size 1 Second 3 Seconds Per Mtr Mtr 13.2 13.2 26.4 13.2 26.4 13.2 13.2 26.4 13.2 26.4 7.6 7.6 15.2 7.6 15.2 7.6 7.6 15.2 7.6 15.2 0.77 0.77 1.53 0.77 1.53 0.77 0.77 1.53 0.77 1.53 50 50 40 50 40 50 50 40 50 40

Part Number TT253BL TT253B TT256B TT253GR TT256GR TT253G TT253S TT256S TT253W TT256W

Black Brown
TL 253

Green Grey Stone

TL 253

White

Lead Covered Copper Tape


Size 25 x 3 38 X 5 mm2 75.00 190.00 KA Rating KA Rating 1 Second 3 Seconds 13.2 33.4 7.6 19.3 Weight Per Mtr 2.56 6.70 Coil Size Mtr 25 25 Part Number TL 253 TL 385

Size

62

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

CONDUCTORS
Hard Drawn Copper Bar
Hard drawn high conductivity (HDHC) solid copper bar. Maximum standard length 4 metres. Copper Bar
Size 12 x 3 20 x 3 20 x 5 25 x 3 25 x 4 25 x 5 25 x 6 30 x 5 31 x 25 38 x 3 38 x 4 38 x 6 40 x 3 40 x 5 40 x 6 40 x 10 50 x 5 50 x 6 50 x 10 50 x 12 60 x 5 60 x 8 60 x 10 75 x 6 75 x 10 75 x 12 80 x 5 80 x 6 80 x 10 80 x 12 100 x 5 100 x 6 100 x 10 100 x 20 mm2 36 60 100 75 100 125 150 150 775 114 152 228 120 200 240 200 250 300 500 600 300 480 600 450 750 900 400 480 800 960 500 600 1000 2000 KA Rating 1 Second 6.3 10.6 17.6 13.2 17.6 22.0 26.4 26.4 136.4 20.1 26.8 40.1 21.1 35.2 42.2 35.2 44.0 52.8 88.0 105.6 52.8 42.2 105.6 79.2 132.0 158.4 70.4 84.4 140.8 168.9 88.0 105.6 176.0 352.0 KA Rating 3 Seconds 3.6 6.1 10.2 7.6 10.2 12.7 15.2 15.2 79.0 11.6 15.5 23.2 12.2 20.3 24.4 20.3 25.4 30.5 50.8 61.0 30.5 24.4 50.8 45.9 76.5 91.8 40.8 48.9 81.6 97.9 51.0 50.8 102.0 204.0 Weight Per Mtr 0.32 0.54 0.90 0.67 0.90 1.12 1.33 1.33 6.97 1.03 1.37 2.03 1.08 1.80 2.16 1.80 2.25 2.67 4.45 5.40 2.67 4.32 5.40 4.00 6.75 8.10 3.60 4.32 7.20 8.64 4.50 5.38 9.00 18.00 Part Number HD1203 HD2003 HD2005 HD2503 HD2504 HD2505 HD2506 HD3005 HD3125 HD3803 HD3804 HD3806 HD4003 HD4005 HD4006 HD4010 HD5005 HD5006 HD5010 HD5012 HD6005 HD6008 HD6010 HD7506 HD7510 HD7512 HD8005 HD8006 HD8010 HD8012 HD1005 HD1006 HD10010 HD10020
HD 7506 HD 5006 HD 2506

Hard Drawn Copper to BS2874 C101/C103. Tinned Copper Bar


Size 25 x 3 25 x 6 38 x 6 50 x 6 50 x 8 50 x 10 mm2 75 150 228 300 400 500 KA Rating 1 Second 13.2 26.4 40.1 52.8 70.4 88.0 KA Rating 3 Seconds 7.6 15.2 23.2 30.5 40.8 51.0 Weight Per Mtr 0.67 1.33 2.03 2.67 7.60 4.50 Part Number HDT2503 HDT2506 HDT3806 HDT5006 HDT5008 HDT5010
Size

Hard Drawn Bar supplied in maximum of 4 Mtr lengths.


A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

63

CONDUCTORS
Flexible Copper Braid
High conductivity copper wire braid manufactured in accordance with BS4109 C101. Suitable for a flexible earthbond where movement of the items to be bonded must be considered. Bare Copper Braid
Size 12 x 1 15 x 1.5 19 x 2.5 25 x 3.5 32 x 6 mm2 6 10 16 35 70 Weight Per Mtr 0.05 0.09 0.16 0.28 0.63 Coil Size Mtr 100 50 50 50 50 Part Number FB121 FB155 FB192 FB253 FB326

Tinned Copper Braid


Size
FB253

mm2 35

Weight Per Mtr 0.28

Coil Size Mtr 50

Part Number FBT253

25 x 3.5

Material: Copper - BS4109 C101.


Size

Aluminium Tape
This Wallis bare and PVC aluminium tape is used on the lightning protection application. It is manufactured in accordance with BS2898-1350. The aluminium tape is annealed for ease of use with radiused edges. Bare Tape
Size 20 x 3 25 x 3 25 x 6 50 x 6 mm2 60 75 150 300 Weight Per Mtr 0.15 0.20 0.41 0.81 Coil Size Mtr 100 50 50 50 Part Number TA 203 TA 253 TA 256 TA 506

PVC Covered
PVC Colour Black Black Brown Green Grey Stone White Size 20 x 3 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3 25 x 3 CSA mm2 60 75 75 75 75 75 75 Weight Per Metre 0.20 0.30 0.30 0.30 0.30 0.30 0.30 Coil Size 100 50 50 50 50 50 50 Part Number TAP 203 BL TAP 253 BL TAP 253 B TAP 253 GR TAP 253 G TAP 253 S TAP 253 W

Material: Aluminium - BS2898-1350.


Size L

64

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

CONDUCTORS
Solid Circular Conductors
This Wallis bare and PVC conductor is used on the lightning protection application. It is manufactured in accordance with BS1432 C101 for the copper and BS2898-1350 for aluminium. Bare Copper
Size 8 mm2 50.27 Weight Per Mtr 0.44 Coil Size Mtr 50 Part Number CSC 08

PVC - Copper
Colour Black Brown Grey Stone White 8 Size mm2 50.27 50.27 50.27 50.27 50.27
CSC 08

Weight Per Metre 0.49 0.49 0.49 0.49 0.49

Coil Size Mtr 50 50 50 50 50

Part Number CPC 08BL CPC 08B CPC 08G CPC 08S CPC 08W
CPC 08S CPC 08G

Bare Aluminium
Size 8 mm2 50.27 Weight Per Mtr 0.14 Coil Size Mtr 50 Part Number CSA 08

PVC - Aluminium
Colour Black Brown Grey Stone White 8 Size mm2 50.27 50.27 50.27 50.27 50.27 Weight Per Mtr 0.185 0.185 0.185 0.185 0.185 Coil Size Mtr 50 50 50 50 50 Part Number
CPC 08W

CPA 08BL CPA 08B CPA 08G CPA 08S CPA 08W
CSA 08

Material: Copper - BS4132 C101. Aluminium - BS2898-1350.


CPA 08B

CPA 08BL

Size

Colour

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

65

CONDUCTORS
Stranded Copper Conductor
Stranded conductor - Soft drawn. Manufactured in accordance with BS 6360. Bare
Size 6
CBS 016

Stranding 7 / 1.04 7 / 1.70 7 / 2.14 19 / 1.53 19 / 1.78 19 / 2.14 19 / 2.52 37 / 2.03 37 / 2.25 37 / 2.52 61 / 2.25 61 / 2.52 61 / 2.85

Weight Per Mtr 0.05 0.15 0.23 0.32 0.43 0.62 0.86 1.09 1.33 1.67 2.2 2.76 3.53

Part Number CBS 006 CBS 016 CBS 025 CBS 035 CBS 050 CBS 070 CBS 095 CBS 120 CBS 150 CBS 185 CBS 240 CBS 300 CBS 400

16 25 35 50

CBS 025

70 95 120 150 185 240 300 400

CBS 050

Green / Yellow PVC Covered


CPS 016

Size 6 16 25 35

Stranding 7 / 1.04 7 / 1.70 7 / 2.14 19 / 1.33 19 / 1.78 19 / 2.14 19 / 2.52 31 / 2.03 37 / 2.25 37 / 2.52 61 / 2.25 61 / 2.52 61 / 2.85

Weight Per Mtr 0.05 0.15 0.23 0.32 0.43 0.62 0.86 1.09 1.33 1.67 2.2 2.76 3.53

Part Number CPS 006 CPS 016 CPS 025 CPS 035 CPS 050 CPS 070 CPS 095 CPS 120 CPS 150 CPS 185 CPS 240 CPS 300 CPS 400

CPS 035

50 70 95 120 150 185 240 300 400

Material: Copper.

Size

66

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LUGS
Compression Lugs
Compression fittings manufactured from high conductive pure electrolytic copper and tin plated to provide excellent corrosion resistance.
Cable Dia mm2 6 6 6 10 10 10 10 16 16 16 16 25 25 25 35 35 35 50 50 50 70 70 70 95 95 120 120 150 150 150 150 185 185 185 185 240 240 300 300 Hole Size mm 4 6 10 6 8 10 12 6 8 10 12 8 10 12 8 10 12 8 10 12 8 10 12 10 12 12 16 10 12 14 16 10 12 14 16 12 16 12 16 L 22.5 22.5 31.0 27.0 35.0 39.0 39.0 29.5 38.0 42.0 42.0 40.0 44.0 44.0 41.0 45.0 45.0 46.0 50.0 50.0 48.0 52.0 52.0 58.0 58.0 73.0 73.0 70.0 78.0 78.0 78.0 82.0 82.0 82.0 82.0 88.0 88.0 97.0 97.0 W 5.3 5.3 5.3 6.9 6.9 6.9 6.9 8.0 8.0 10.0 8.0 9.5 9.5 9.5 11.0 11.0 11.0 12.1 12.1 12.1 15.0 15.0 15.0 17.0 17.0 19.0 19.0 21.0 21.0 21.0 21.0 21.0 23.0 23.0 23.0 26.0 26.0 28.0 28.0 Pack Qty 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 50 50 50 25 25 25 25 25 25 25 25 10 10 10 10 10 10 10 10 Part Number CLG 100 CLG 101 CLG 103 CLG 200 CLG 201 CLG 202 CLG 203 CLG 300 CLG 301 CLG 302 CLG 303 CLG 400 CLG 401 CLG 402 CLG 500 CLG 501 CLG 502 CLG 602 CLG 603 CLG 604 CLG 702 CLG 703 CLG 704 CLG 803 CLG 804 CLG 904 CLG 906 CLG 113 CLG 114 CLG 115 CLG 116 CLG 223 CLG 224 CLG 225 CLG 226 CLG 334 CLG 335 CLG 344 CLG 345

Material: Pure electrolytic copper tin plated.

D L

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

67

SPLIT BOLTS AND EARTH BLOCKS


Split Bolt Connector
Split bolt connectors will accept a range of stranded or solid circular conductors. No specialist tools are required for installation.
Conductor Minimum 10 25 35 50
SBC 2535 SBC 50120

Conductor Maximum 16 35 50 95 120

W 5.5 8.4 9.7 13.6 14.7

Weight 0.03 0.02 0.09 0.17 0.18

Pack Qty 10 10 10 10 10

Part Number SBC 1016 SBC 2535 SBC 3550 SBC 5095 SBC 50120

50

Material: High Strength Copper Alloy. Bronze Bolt.

W W

Earth Blocks
These Wallis blocks allow earth conductor termination, or live conductor termination with a suitable, fully insulated housing.
Way
EBB 004

Type single double double

L 54 51 88

W 18 19 19

D 12 12 12

Weight 0.06 0.09 0.15

Box Qty 10 10 10

Part Number EBB 004/1 EBB 004 EBB 008

4
EBB 008

4 8

EBB 004/1

Material: Tinned Brass.

68

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Hexagon Head Set Screw
Size mm 08 x 25 10 x 25 10 x 35 12 x 35 10 x 25 10 x 35 12 x 25 12 x 35 08 x 25 10 x 25 10 x 35 12 x 35 Material Brass Brass Brass Brass Phos Bronze Phos Bronze Phos Bronze Phos Bronze S/Steel S/Steel S/Steel S/Steel Weight 0.02 0.03 0.03 0.04 0.03 0.03 0.04 0.04 0.02 0.03 0.03 0.04 Pack Qty 100 100 100 100 100 100 100 100 100 100 100 100 Part Number OSB 0825 OSB 1025 OSB1035 OSB1235 OSP1025 OSP1035 OSP1225 OSP1235 OSS0825 OSS1025 OSS1035 OSS1235

Hexagon Nuts
Size mm 8 10 12 10 12 8 10 12 Material Brass Brass Brass Phos Bronze Phos Bronze S/Steel S/Steel S/Steel Weight 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 Pack Qty 100 100 100 100 100 100 100 100 Part Number ONB08 ONB10 ONB12 ONP10 ONP12 ONS08 ONS10 ONS12

C Crimp Connectors
These range taking connectors are mainly used for tap or parallel connections of copper cable in earthing applications. They must be installed using the appropriate tool and dies. They can be installed in all weather conditions and are heat resistant up to +105C.
Conductor Minimum 16 25 50 70 95 120 120 150 Type Maximum 35 35 70 70 120 120 240 240 C C C C C Tap C C Pack Qty 25 25 50 50 50 50 10 10 Part Number YC4C4 YC2C4 YC26C2 YC26C26 YC185M YC29C29 YGHC34C29 YGHC34C34

Material: Extruded Electrolytic Copper - thick wall.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

69

LIGHTNING PROTECTION
Washers
Flat Washer
Size mm 8 10 12 8 10 12 8 10 12 Material Brass Brass Brass Phos Bronze Phos Bronze Phos Bronze S/Steel S/Steel S/Steel Pack Qty 100 100 100 100 100 100 100 100 100 Part Number OWB08 OWB10 OWB12 OWP08 OWP10 OWP12 OWS08 OWS10 OWS12

Spring Washer
Size mm 8 10 12 Material Phos Bronze Phos Bronze Phos Bronze Pack Qty 100 100 100 Part Number OTP08 OTP10 OTP12

Singular Weight - 0.003.

Rivets
Size mm 5 X 12 5 X 20 5 X 12 5 X 20 Material Copper Copper Aluminium Aluminium Pack Qty 100 100 100 100 Part Number ORC512 ORC520 ORA512 ORA520

Singular Weight - 0.003.

70

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

LIGHTNING PROTECTION
Countersunk Wood Screw
Size mm 11/4 x 10 11/2 x 12 Material S/Steel Brass Pack Qty 100 100 Part Number OAS132 OAB 139

Singular Weight - 0.006.

Round Head Nails


Size Length mm 50 Material Copper Pack Qty 100 Part Number OCN 050

Singular Weight - 0.004.

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

71

LIGHTNING PROTECTION
Plastic Wall Plugs
Size mm No 10 -12 Material Plastic Pack Qty 10 Part Number OP10

Tower Mast Coupling


L 65 H 36 Weight 0.09 Pack Qty 1 Part Number SAM 01

Material: Aluminium.

72

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

PART NUMBER INDEX


A ABHA 16. . . . . . 35 ABHG 16 . . . . . 35 AMBA 16 . . . . . 34 AMBA 20 . . . . . 34 AMBG 16 . . . . . 34 AMBG 20 . . . . . 34 AOA 16 . . . . . . . 35 AOA 20 . . . . . . . 35 AOG 16 . . . . . . . 35 AOG 20. . . . . . . 35 ARA 102 . . . . . . 47 ARA 105 . . . . . . 47 ARC 102 . . . . . . 47 ARC 105 . . . . . . 47 ASAF 16 . . . . . 33 ASAF 20 . . . . . 33 ASAL 16 . . . . . . 34 ASAL 20 . . . . . . 34 ASAR 16 . . . . . . 33 ASAR 20. . . . . . 33 ASGF 16 M. . . . 33 ASGF 20 . . . . . 33 ASGL 16 M. . . . 34 ASGL 20 . . . . . 34 ASGR 16 M . . . 33 ASGR 20 . . . . . 33 ATA 112. . . . . . . 32 ATA 120 . . . . . . 32 ATA 139 . . . . . . 32 ATA 160 . . . . . . 32 ATA 172. . . . . . . 32 ATA 179. . . . . . . 32 ATC 112 M . . . . 32 ATC 120 M . . . . 32 ATC 139 M . . . . 32 ATC 160 M . . . . 32 ATC 172 M . . . . 33 ATC 179 M . . . . 32 ATC 220 M . . . . 32 ATC 239 M . . . . 32 ATC 279 M . . . . 32 AVG . . . . . . . . . . 56 AVG 3 . . . . . . . . 56 B BBA 08 . . . . . . . 54 BBA 253 . . . . . . 44 BBG 08 . . . . . . . 54 BBG 253 SS . . 44 BBG 253. . . . . . 44 BFB . . . . . . . . . . 58 BFE 200 . . . . . . 59 BFE 400 . . . . . . 59 BFE 300 . . . . . . 59 BFR 01 . . . . . . . 58 BIM 08 . . . . . . . 54 BIM 253 . . . . . . 44 BIM 253 08 . . . 54 BRA 08 . . . . . . . 51 BRA 253. . . . . . 45 BRG 08 . . . . . . . 51 BRG 253. . . . . . 45 BSS 08 . . . . . . . 54 BSS 253 . . . . . . 44 BTC 016 . . . . . . 53 BTC 070 . . . . . . 53 BTC 216 . . . . . . 53 BTC 270 . . . . . . 53 BWG 253 . . . . . 45 C CBS 006 . . . . . . 66 CBS 016 . . . . . . 66 CBS 025 . . . . . . 66 CBS 035 . . . . . . 66 CBS 050 . . . . . . 66 CBS 070 . . . . . . 66 CBS 095 . . . . . . 66 CBS 120 . . . . . . 66 CBS 150 . . . . . . 66 CBS 185 . . . . . . 66 CBS 240 . . . . . . 66 CBS 300 . . . . . . 66 CBS 400 . . . . . . 66 CLG 100 . . . . . . 67 CLG 101 . . . . . . 67 CLG 103 . . . . . . 67 CLG 113 . . . . . . 67 CLG 114 . . . . . . 67 CLG 115 . . . . . . 67 CLG 116 . . . . . . 67 CLG 200 . . . . . . 67 CLG 201 . . . . . . 67 CLG 203 . . . . . . 67 CLG 223 . . . . . . 67 CLG 224 . . . . . . 67 CLG 225 . . . . . . 67 CLG 226 . . . . . . 67 CLG 300 . . . . . . 67 CLG 301 . . . . . . 67 CLG 302 . . . . . . 67 CLG 303 . . . . . . 67 CLG 334 . . . . . . 67 CLG 335 . . . . . . 67 CLG 344 . . . . . . 67 CLG 345 . . . . . . 67 CLG 400 . . . . . . 67 CLG 401 . . . . . . 67 CLG 402 . . . . . . 67 CLG 500 . . . . . . 67 CLG 501 . . . . . . 67 CLG 502 . . . . . . 67 CLG 602 . . . . . . 67 CLG 603 . . . . . . 67 CLG 604 . . . . . . 67 CLG 702 . . . . . . 67 CLG 703 . . . . . . 67 CLG 704 . . . . . . 67 CLG 803 . . . . . . 67 CLG 804 . . . . . . 67 CLG 904 . . . . . . 67 CLG 906 . . . . . . 67 CM 08 B . . . . . . 48 CM 08 G . . . . . . 48 CP 08 B . . . . . . 48 CP 08 BL . . . . . 48 CP 08 G . . . . . . 48 CP 08 S . . . . . . 48 CP 08 W . . . . . . 48 CPA 08 B . . . . . 65 CPA 08 BL . . . . 65 CPA 08 G . . . . . 65 CPA 08 S . . . . . 65 CPA 08 W. . . . . 65 CPC 08 B . . . . . 65 CPC 08 BL . . . . 65 CPC 08 G . . . . . 65 CPC 08 S . . . . . 65 CPC 08 W . . . . 65 CPS 006 . . . . . . 66 CPS 016 . . . . . . 66 CPS 025 . . . . . . 66 CPS 035 . . . . . . 66 CPS 050 . . . . . . 66 CPS 070 . . . . . . 66 CPS 095 . . . . . . 66 CPS 120 . . . . . . 66 CPS 150 . . . . . . 66 CPS 185 . . . . . . 66 CPS 240 . . . . . . 66 CPS 300 . . . . . . 66 CPS 400 . . . . . . 66 CSA 08 . . . . . . . 65 CSC 08 . . . . . . . 65 D DAP 253 . . . . . . 37 DAP 256 . . . . . . 37 DAP 506 . . . . . . 37 DCA 203 . . . . . . 37 DCA 253 . . . . . . 37 DCA 256 . . . . . . 37 DCA 386 . . . . . . 37 DCA 506 . . . . . . 37 DCA 810 . . . . . . 49 DCA 815 . . . . . . 49 DCB 203. . . . . . 37 DCB 253. . . . . . 37 DCB 506. . . . . . 37 DCG 123. . . . . . 37 DCG 254. . . . . . 37 DCG 256. . . . . . 37 DCG 313 . . . . . . 37 DCG 316 . . . . . . 37 DCG 383. . . . . . 37 DCG 385. . . . . . 37 DCG 386. . . . . . 37 DCG 503. . . . . . 37 DCG 504. . . . . . 37 DCG 810. . . . . . 49 DCG 815. . . . . . 49 DCL 253 . . . . . . 37 DCL 385 . . . . . . 37 DGP 253. . . . . . 37 DGP 256. . . . . . 37 DGP 385. . . . . . 37 DGP 503. . . . . . 37 DGP 506. . . . . . 37 DT 510. . . . . . . . 57 E EBB 004 . . . . . . 68 EBB 004/1 . . . . 68 EBB 008 . . . . . . 68 EBC 001 . . . . . . 19 EBC 004 . . . . . . 28 EBC 006 . . . . . . 28 EBC 008 . . . . . . 28 EBC 010 . . . . . . 28 EBC 012 . . . . . . 28 EBC 014 . . . . . . 28 EBC 05 . . . . . . . 29 EBC 07 . . . . . . . 29 EBC 104 . . . . . . 28 EBC 106 . . . . . . 28 EBC 108 . . . . . . 28 EBC 110 . . . . . . 28 EBC 112 . . . . . . 28 EBC 114 . . . . . . 28 EBC 206 . . . . . . 28 EBC 25 . . . . . . . 29 EBC 27 . . . . . . . 29 EBC 35 . . . . . . . 29 EBC 37 . . . . . . . 29 EBG 25 . . . . . . . 21 EBG 25 P . . . . . 21 EBI 001 . . . . . . . 29 EBI 002 . . . . . . . 29 EGP 01 . . . . . . . 26 EGP 01 500 . . . 26 EGP 02 . . . . . . . 26 EGP 02 1000 . . 26 EGP 02 1500 . . 26 EGP 02 3000. . 26 EGP 02 500 . . . 26 EGP 04 . . . . . . . 26 EGP 04 1000 . . 26

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

73

PART NUMBER INDEX


EGP 04 3000. . 26 EGP 04 500 . . . 26 EMA 25 . . . . . . . 21 EML 603. . . . . . 20 EML 903. . . . . . 20 EML 903 SPC . 20 EMP 601. . . . . . 20 EMP 603. . . . . . 20 EMP 901. . . . . . 20 EMP 903. . . . . . 20 EPB 01 . . . . . . . 27 EPP 001 . . . . . . 22 EPP 002 . . . . . . 22 ERA 1625 . . . . . 16 ERA 1625 A . . . 16 ERA 1625 SS . . 16 ERA 1631 . . . . . 16 ERA 1638 . . . . . 16 ERA 1650 . . . . . 16 ERA 2525 . . . . . 16 ERB 012 . . . . . . 12 ERB 112 . . . . . . 10 ERB 115 . . . . . . 10 ERB 118 . . . . . . 10 ERB 120 . . . . . . 10 ERB 124 . . . . . . 10 ERB 130 . . . . . . 10 ERB 212 . . . . . . 10 ERB 215 . . . . . . 10 ERB 218 . . . . . . 10 ERB 220 . . . . . . 10 ERB 224 . . . . . . 10 ERB 230 . . . . . . 10 ERB 412 . . . . . . 10 ERB 415 . . . . . . 10 ERB 418 . . . . . . 10 ERB 424 . . . . . . 10 ERB 612 . . . . . . 12 ERB 615 . . . . . . 12 ERB 618 . . . . . . 12 ERB 620 . . . . . . 12 ERB 624 . . . . . . 12 ERB 630 . . . . . . 12 ERB 712 . . . . . . 12 ERB 715 . . . . . . 12 ERB 718 . . . . . . 12 ERB 720 . . . . . . 12 ERB 724 . . . . . . 12 ERB 730 . . . . . . 12 ERB 812 . . . . . . 12 ERB 815 . . . . . . 12 ERB 818 . . . . . . 12 ERB 820 . . . . . . 12 ERB 824 . . . . . . 12 ERB 830 . . . . . . 12 ERB 930 . . . . . . 12 ERBD 06. . . . . . 13 ERBD 07 . . . . . . 13 ERBD 08. . . . . . 13 ERBD 12 . . . . . . 11 ERBD 16 . . . . . . 11 ERBD 20 . . . . . . 11 ERBO 06. . . . . . 13 ERBO 07. . . . . . 13 ERBO 08. . . . . . 13 ERBO 12 . . . . . . 11 ERBO 16 . . . . . . 11 ERBO 20. . . . . . 11 ERC 112 . . . . . . 14 ERC 115 . . . . . . 14 ERC 118 . . . . . . 14 ERC 124 . . . . . . 14 ERC 130 . . . . . . 14 ERC 212 . . . . . . 14 ERC 215 . . . . . . 14 ERC 218 . . . . . . 14 ERC 224 . . . . . . 14 ERC 230 . . . . . . 14 ERC 26 . . . . . . . 19 ERCD 16 . . . . . . 15 ERCD 20. . . . . . 15 ERCS 16 . . . . . . 15 ERCS 20 . . . . . . 15 ERD 01 . . . . . . . 15 ERD 16 . . . . . . . 15 ERH 01 . . . . . . . 24 ERH 20 . . . . . . . 23 ERH 21 . . . . . . . 23 ERR 1035 . . . . . 17 ERR 1635 . . . . . 17 ERR 1670 . . . . . 17 ERR 2095 . . . . . 17 ERSO 10 . . . . . . 19 ERSO 16 . . . . . . 19 ERSO 20. . . . . . 19 ERSS 16 . . . . . . 19 ERSS 20 . . . . . . 19 ERU 016 . . . . . . 18 ERU 025 . . . . . . 18 ERU 031 . . . . . . 18 ERU 038 . . . . . . 18 ERU 050 . . . . . . 18 ERU 216 . . . . . . 18 ERU 225 . . . . . . 18 ERU 231 . . . . . . 18 ERU 238 . . . . . . 18 ERU 250 . . . . . . 18 ERU 470 . . . . . . 18 ERU 570 . . . . . . 18 ERX 05 . . . . . . . 25 ERY 10 . . . . . . . 55 ERZ 112 . . . . . . 14 EYEBOLT . . . . . 27 F FB 121. . . . . . . . 64 FB 151. . . . . . . . 64 FB 192 . . . . . . . 64 FB 253 . . . . . . . 64 FB 326 . . . . . . . 64 FBT 253 . . . . . . 64 HA 08 G . . . . . . 49 HBP . . . . . . . . . . 41 HC 08 B . . . . . . 49 HCA 253. . . . . . 39 HCG 253 . . . . . 39 HD 10005 . . . . . 63 HD 10006 . . . . . 63 HD 10010 . . . . . 63 HD 10020 . . . . . 63 HD 1203 . . . . . . 63 HD 2003 . . . . . . 63 HD 2005 . . . . . . 63 HD 2503 . . . . . . 63 HD 2504 . . . . . . 63 HD 2505 . . . . . . 63 HD 2506 . . . . . . 63 HD 3005 . . . . . . 63 HD 3125 . . . . . . 63 HD 3803 . . . . . . 63 HD 3804 . . . . . . 63 HD 3806 . . . . . . 63 HD 4003 . . . . . . 63 HD 4005 . . . . . . 63 HD 4006 . . . . . . 63 HD 4010 . . . . . . 63 HD 5005 . . . . . . 63 HD 5006 . . . . . . 63 HD 5010 . . . . . . 63 HD 5012 . . . . . . 63 HD 6005 . . . . . . 63 HD 6008 . . . . . . 63 HD 6010 . . . . . . 63 HD 7506 . . . . . . 63 HD 7510 . . . . . . 63 HD 7512 . . . . . . 63 HD 8005 . . . . . . 63 HD 8006 . . . . . . 63 HD 8010 . . . . . . 63 HD 8012 . . . . . . 63 HDT 2503. . . . . 63 HDT 2506. . . . . 63 HDT 3806. . . . . 63 HDT 5006. . . . . 63 HDT 5008. . . . . 63 HDT 5010 . . . . . 63 HGA 253 . . . . . 38 HGG 253 . . . . . 38 HSAL 253 B . . . 39 HSAL 253 G. . . 39 HSAL 253 GM . 39 HSAL 253 MB . 39 I IC08. . . . . . . . . . 58 J JA 253. . . . . . . . 42 JA 256. . . . . . . . 42 JA 386. . . . . . . . 42 JA 506. . . . . . . . 42 JAO 253 . . . . . . 42 JAO 506 . . . . . . 42 JG 253 . . . . . . . 42 JG 256 . . . . . . . 42 JG 313. . . . . . . . 42 JG 386 . . . . . . . 42 JG 503 . . . . . . . 42 JG 506 . . . . . . . 42 JGO 253 . . . . . . 42 JGO 316 . . . . . . 42 JGO 386 . . . . . . 42 JGO 506 . . . . . . 42 JOA 253 . . . . . . 46 JOM 253. . . . . . 46 JPA 253 . . . . . . 43 JPB 253 L . . . . 42 JPBO 253 L . . . 42 JPG 253 . . . . . . 43 JSG 253 . . . . . . 43 JTA 08. . . . . . . . 52 JTG 08 . . . . . . . 52 JYA 08. . . . . . . . 52 JYG 08 . . . . . . . 52 M MAP 253 . . . . . 38 MBA 08 . . . . . . . 51 MBG 08. . . . . . . 51 MPB 253 . . . . . 38 MPC 16. . . . . . . 36 MTA 203 . . . . . . 38 MTA 253 . . . . . . 38 MTB 203. . . . . . 38 MTB 253. . . . . . 38 MTB 506. . . . . . 38 MVA 08 . . . . . . . 50 MVG 08. . . . . . . 50 N NB 01 B . . . . . . 41 NB 01 BL . . . . . 41 NB 01 G . . . . . . 41 NM 203 B. . . . . 40 NM 203 G. . . . . 40 NM 253 G. . . . . 40 NM 253 B. . . . . 40 NM 506 B. . . . . 40 NMP 203 B . . . 40 NMP 203 G . . . 40

74

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

PART NUMBER INDEX


NMP 253 B . . . 40 NMP 253 G . . . 40 NP 253 B . . . . . 40 NP 253 BL . . . . 40 NP 253 G . . . . . 40 NP 253 GR. . . . 40 NP 253 S . . . . . 40 NP 253 W. . . . . 40 NPP 253 B . . . . 40 NPP 253 BL. . . 40 NPP 253 G. . . . 40 NPP 253 GR . . 40 NPP 253 S . . . . 40 NPP 253 W . . . 40 O OAB 139 . . . . . . 71 OAS 132 . . . . . . 71 OCN 050. . . . . . 71 ONB 08. . . . . . . 69 ONB 10. . . . . . . 69 ONB 12 . . . . . . . 69 ONP 10 . . . . . . . 69 ONP 12 . . . . . . . 69 ONS 08 . . . . . . . 69 ONS 10 . . . . . . . 69 ONS 12 . . . . . . . 69 ORA 512 . . . . . . 70 ORA 520. . . . . . 70 ORC 512 . . . . . . 70 ORC 520 . . . . . 70 OSB 0825. . . . . 69 OSB 1025. . . . . 69 OSB 1035. . . . . 69 OSB 1235. . . . . 69 OSP 1025. . . . . 69 OSP 1035. . . . . 69 OSP 1225 . . . . . 69 OSP 1235 . . . . . 69 OSS 0825 . . . . 69 OSS 1025 . . . . . 69 OSS 1035 . . . . . 69 OSS 1235 . . . . . 69 OTP 08 . . . . . . . 70 OTP 10 . . . . . . . 70 OTP 12 . . . . . . . 70 OWB 08 OWB 10 OWB 12 OWP 08 OWP 10 OWP 12 . . . . . . 70 . . . . . . 70 . . . . . . 70 . . . . . . 70 . . . . . . 70 . . . . . . 70 TAP 253 B . . . . 64 TAP 253 BL . . . 64 TAP 253 G . . . . 64 TAP 253 GR. . . 64 TAP 253 S . . . . 64 TAP 253 W . . . . 64 TC 121 TC 123 TC 201 TC 203 TC 251 TC 253 TC 254 TC 256 TC 303 TC 304 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 TP 253 GRLSF 61 TP 253 GY . . . . 61 TP 253 S. . . . . . 61 TP 253 W . . . . . 61 TP 253 WLSF. . 61 TP 256 B . . . . . 61 TP 256 GR . . . . 61 TP 256 GRLSF 61 TP 256 GY . . . . 61 TP 256 W . . . . . 61 TP 506 GR . . . . 61 TP 506 GRLSF 61 TP 506 S. . . . . . 61 TT 121. . . . . . . . 62 TT 123. . . . . . . . 62 TT 203 . . . . . . . 62 TT 251. . . . . . . . 62 TT 253 . . . . . . . 62 TT 253 B . . . . . 62 TT 253 BL . . . . 62 TT 253 G . . . . . 62 TT 253 GR . . . . 62 TT 253 S. . . . . . 62 TT 253 W . . . . . 62 TT 254 . . . . . . . 62 TT 256 . . . . . . . 62 TT 256 B . . . . . 62 TT 256 GR . . . . 62 TT 256 S. . . . . . 62 TT 256 W . . . . . 62 TT 302 . . . . . . . 63 TT 313. . . . . . . . 62 TT 383 . . . . . . . 62 TT 385 . . . . . . . 64 TT 403 . . . . . . . 62 TT 406 . . . . . . . 62 TT 503 . . . . . . . 62 TT 506 . . . . . . . 62 U UAA 08 . . . . . . . 47 UAA 08 V . . . . . 47 UAG 08 . . . . . . . 47 UAG 08 V . . . . . 47 UC 070 . . . . . . . 46 UC 095 . . . . . . . 46 UC 120 . . . . . . . 46 Y YC 185 M . . . . . 69 YC 2 C2 . . . . . . 69 YC 2 C4 . . . . . . 69 YC 29 C29 . . . . 69 YC 26 C2 . . . . . 69 YC 26 C26 . . . . 69 YC 4 C4 . . . . . . 69 YGH 34 C29. . . 69 YGH C34 C34 . 69

OWS 08 . . . . . . 70 OWS 10 . . . . . . 70 OWS 12. . . . . . . 70 P PCA 001 . . . . . . 55 PCA 002 . . . . . . 55 PCC 001 . . . . . . 55 PCC 002. . . . . . 55 PCC 003. . . . . . 55 PCC 004. . . . . . 55 PES . . . . . . . . . . 25 PFA 01 . . . . . . . 56 PFC 01 . . . . . . . 56 R RM 08 B . . . . . . 48 RM 08 G . . . . . . 48 RP 08 B . . . . . . 48 RP 08 BL . . . . . 48 RP 08 G . . . . . . 48 RP 08 S . . . . . . 48 RP 08 W . . . . . . 48 S SA 01 . . . . . . . . 36 SBC 1016 . . . . . 68 SBC 2535. . . . . 68 SBC 3550. . . . . 68 SBC 50120. . . . 68 SBC 5095. . . . . 68 SC 01 . . . . . . . . 36 Silfos . . . . . . . . . 57 SPA . . . . . . . . . . 59 SPC . . . . . . . . . . 59 T TA 203 . . . . . . . 64 TA 253 . . . . . . . 64 TA 256 . . . . . . . 64 TA 506 . . . . . . . 64 TAP 203 BL . . . 64

TC 305 . . . . . . . 60 TC 313 . . . . . . . 60 TC 3156 . . . . . . 60 TC 316 . . . . . . . 60 TC 383 . . . . . . . 60 TC 385 TC 386 TC 403 TC 404 TC 405 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60 . . . . . . . 60

TC 406 . . . . . . . 60 TC 4063 . . . . . . 60 TC 503 . . . . . . . 60 TC 504 . . . . . . . 60 TC 505 . . . . . . . 60 TC 506 . . . . . . . 60 TC 5063 . . . . . . 61 TCA 08 . . . . . . . 50 TCG 08 . . . . . . . 50 TL 253 . . . . . . . 62 TL 385 . . . . . . . 62 TP 121 BL. . . . . 61 TP 121 BLLSF . 61 TP 203 GR . . . . 61 TP 253 B . . . . . 61 TP 253 BL . . . . 61 TP 253 G . . . . . 61 TP 253 GLSF . . 61 TP 253 GR . . . . 61

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

75

NOTES

76

A. N. WALLIS & Co. Ltd Telephone +44 (0)115 927 1721 Fax +44 (0)115 875 6630 E-mail info@an-wallis.com Website www.an-wallis.com

NOTES

Copyright: This brochure is Copyrighted to A. N. Wallis & Co. Ltd. Unauthorised reproduction or storage without permission is an infringement of that Copyright. Infringement of Copyright will result in legal actions. February 2003

Designed and produced by McConnells Advertising & PR, Derby