Professional Documents
Culture Documents
MED B-7488 Product: Density: Thickness: SeaRox SL 640 130 kg/m3 Plate 40 mm insulation Stiffener 40 mm insulation
Construction: Plate between stiffeners insulated with one layer of 40 mm SeaRox SL 640. Stiffeners insulated with min. 40 mm SeaRox SL 640. Standard steel plate 4.5 mm ( 0.5 mm) thick. 3 mm pins xed with approx 300 mm distance. Insulation secured with washers of 38 mm.
600
600
Application notes: All the connections must be tight, no air gaps. Gap under the stiffener must be lled out completely. The pins should exceed the insulation by approx 10 mm..
Surfaces: Reinforced aluminium foil Glass cloth Sound: Weigthed sound absorption SeaRox SL 640, 40 mm w = 0.75 Weigthed sound reduction of the A-60 application Rw = 56 dB (with 1 mm steel sheet in front of the insulation)
480
4.5 mm steel
PINNING
TEST: G10141/6025
1000
40 mm SeaRox SL 640 4.5 mm steel
32