Electronic Overload Relays


Advantiges:
big current range means less types in a stock less inventory costs exact tripping higher saftety as usual devices easy planning

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

Electronic Overload Relays


Funktions
Motor overload protection IEC 947-4-1. Phase failure protection. Manual and automatic reset. Stop button for starter. Trip indicator. Setting knob for nominal current. Self powered.

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

Electronic Overload Relays


Advantages ( 1 )
Low heat dissipation <0,5W Wide setting range. To be used on A 9 ... A 16 and B 6, B 7. Possible product models with tripping class 20 or 30 Save inventory costs - small stock necessary for example: only 5 variants for the range 0.1 ... 18.9 A.

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

Electronic Overload Relays


Advantages ( 2 )
Expanded temperature range, -25 ... +70 C. Fast phase failure protection. Trip curve is stable over lifetime. Trip curve is stable over temperature. Trip curve is more accurate than TOL. Automatic reset time: 2 minutes.

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

E 16 DU Basic Product

Nominal current setting

RESET manual or automatic Trip indicator TEST function

STOP button

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

E 16 DU Schematics of a motor starter


L1 L2 L3 A1

A2/96

98

Ir

Current Sensors Electronics Trip/Reset Mechanism 2 4 6

EOL
95 97

Load = Motor
RELES TERMICOS ING. HUBER MURILLO MANRIQUE

E 16 DU EOL vs. TOL


Comparison

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

Electronic Overload Relays


Motor overload protection IEC 947-4-1: Class 10 Phase failure protection: 3 seconds in warm state 3...40 seconds in cold state Automatic reset time: 2 minutes Temperature range (compensated): -25 ... +70 C. Ie setting range: 100 ... 300 % Possible product models with tripping class 20 or 30

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

E 16 DU
Current ranges
T yp e E 1 6 D U 0 ,3 2 E 1 6 D U 1 ,0 E 1 6 D U 2 ,7 E 1 6 D U 6 ,3 E 1 6 D U 1 8 ,9 S e ttin g R a n g e A ... A 0 .1 ... 0 .3 2 0 .3 ... 1 .0 0 .9 ... 2 .7 2 .0 ... 6 .3 5 .7 ... 1 8 .9 O rd e r C o d e 1SA X11 1201R0001 1SA X11 1201R0002 1SA X11 1201R0003 1SA X11 1201R0004 1SA X11 1201R0005

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

EOL - Fitting Survey


EOL Conn.capacity rigid [mm] flexible [mm] Width Range(s) CONTACTORS
Width [mm]

E 16 DU

2 x 0,75...4 2 x 0,75...4 45 mm
0,1..0,32/0,3..1,0/0,9..2,7/2,0..6,3/5,7..18,9A

B6 47

B7 47

A9 45

A 12 45

A 16 45

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

EOL - Fitting Survey


EOL Conn.capacity rigid [mm] flexible [mm] Width Range(s) CONTACTORS
Width [mm]

E 200 DU

E 320 DU

E 500 DU

E 800 DU

2 x 70 2 x 70 105 mm 65...200 A 105...320 A


A 145 A 185 105 105 A210 140 A260 140 A300 140

210 mm 245 mm 170...500 A 275...800 A


A400 186 A460 186 A580 210 A750 210

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

E 16 DU fits A9 .. A16 and B6, B7

Fits A 9 ... A 16, B 6, B 7 5 Ranges cover Ie = 0.1 ... 18.9 A Same installation as TOL

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

E200 / E320 DU fitting


E200 / E320 DU Fitting to big A-Contactors

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

E200DU

E320DU

Fits to A145 ... A185 Current range 60 ... 200 A

Fits to A210 ... A300 Current range 96 ... 320 A

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

E800DU

E500DU

Fits to AF580 ... AF750 Current range 240 ... 800 A

Fits to AF400 ... A460 Current range 150 ... 500 A

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

RELES TERMICOS

ING. HUBER MURILLO MANRIQUE

CHARACTERISTICS GTH - 22
COLD START HOT START

FIN
RELES TERMICOS ING. HUBER MURILLO MANRIQUE