You are on page 1of 1

Suggested External Dmg.

Inspection Plan Production Unit


Unique ID 44 89 90 87 91 92 88 79 80 50 51 52 69 70 53 71 72 55 58

Filter: (All)

External Damage
Eqp. ID 17E1B SHELL 17E2 INLET 17E2 OUTLET 17E2 TUBE 17E2K INLET 17E2K OUTLET 17E2K TUBE 17V1 BOTTOM 17V1 TOP LN 17-10 AW 1 LN 17-11 AW 1 LN 17-12 AW 2 LN 17-15 A 2 LN 17-15 A 4 LN 17-15 A 6 LN 17-17 AW 1 LN 17-17 AW 1.5 LN 17-17 AW 2 LN 17-824 A 1

RU IV

Extl. Corrosion
Asset ID

Eqp. Type EXCHANGER FINFAN FINFAN FINFAN FINFAN FINFAN FINFAN DRUM DRUM PIPE-1 PIPE-1 PIPE-2 PIPE-2 PIPE-4 PIPE-6 PIPE-1 PIPE-2 PIPE-2 PIPE-1

Eqp. Name Feed/Effluent Exchanger Stripper Water Effluent Cooler Stripper Water Effluent Cooler Stripper Water Effluent Cooler Stripper Water Effluent Cooler Stripper Water Effluent Cooler Stripper Water Effluent Cooler Sour Water Collecting Vessel Sour Water Collecting Vessel Piping Piping Piping Piping Piping Piping Piping Piping Piping Piping

Insulated Corrosion Future Suggested Is Criteria [y/n] Rate [mm/Yr] Evaluation Inspection Met Date Effectiveness Y N N N N N N N N N N Y N N N N N N N 0.030(Calc) 0.062(Calc) 0.068(Calc) 0.068(Calc) 0.062(Calc) 0.068(Calc) 0.068(Calc) 0.090(Calc) 0.090(Calc) 0.090(Calc) 0.090(Calc) 0.028(Calc) 0.077(Calc) 0.077(Calc) 0.077(Calc) 0.090(Calc) 0.090(Calc) 0.090(Calc) 0.056(Calc) Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 Oct/18/16 None None None None None None None Highly Highly None None None Highly Highly None Highly Highly Highly Highly Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y Y Y

Print date: 26-Dec-11 Page 1 of 1

RBI Pertamina RU IV Cilacap UNIT17~1.ORD