UMG Specification
E1 Capacity 10 k Erl Rated input voltageC48 V/C60 V Power consumption (single frame)1100 W at most (much less than this value when no resource board is available) Maximum input currentsTwo C48 V/C60 V inputs in the hot backup mode: 100 A per input
Mechanical Specification
Cabinet dimensions (height width depth) 2200 mm 600 mm 800 mm Frame dimensions (height width depth)533.4 mm 482.6 mm 500 mm Cabinet weight N68-22 rack: about 95 kg [209 lb]; fully configured N6822 cabinet: about 330 kg [728 lb], including the cabinet doors, three fully configured service frames, ]; Bearing capacity> 600 kg/m2 [0.85 lbf/in.2]
OMU Board
MOMU
System management board of main control frame(SSM256). Provide BAM function. Inserted in slot 7, 8 and work in 1+1 backup. Providing FE switching for internal control and signaling traffic.
MOMB
System management board of main control frame(SSM32). Provide BAM function. Inserted in slot 6/7, 8/9 and work in 1+1 backup. Providing GE switching for IP voice traffic.
MMPB
Configured in SSM32 Slot 6/7, 8/9. Providing GE switching for IP voice traffic. Work in1+1 backup. System management function is implemented by MTNC. Only packet service is required, the MMPB is configured.
MHRD
MHRD is a back board, which equals the combination of HRU + G1O or HRU + E8T. D8FT subboard is inserted in the UG01MHRD1, which provides eight fast Ethernet (FE) interfaces. D1GO subboard is inserted in the UG01MHRD2, which provides one gigabit Ethernet (GE) interface. The ports on the UG02MHRD can work in load-sharing or master/slave mode.
MNET
Receive clock signal from CLK and distribute the clock signal to TDM processing boards within the frame
Work in 1+1 backup mode
MTNB
MTNB configured in SSM256 frame Providing 256k TDM switching function Provide 4*8k TDM cascading connecting Support 1+1 backup work mode MTNB is inserted in back plane slot 6 & 9
MSPF
Implementing the core function of the signaling gateway by supporting the M3UA//M2UA/V5UA/IUA adaptation on signaling, and forwarding adapted messages to the media gateway controller (MGC). Receiving signaling from TDM switching units through the Subboard (SHPU), and processing the TDM signaling.
MVPD
The MVPD enables the following functions: - Supporting functions such as announcement playing, digit collecting, audio mixing and MFC. - Implementing IP packet adaptation of voice services based on UDP, RTP and IP.
MTNC
MTNC provides device management function (MPU function) UG01MTNC can support 32k TDM switching function UG02MTNC can support 96k TDM switching function MTNC supports FE switching function for control plane and internal signaling traffic. MTNC provides clock function through CKMB sub-board MTNC can receive 16 KHz stratum-2 clock from CLK and deliver 8 KHz clock through the TDM cascading path between frames
MCLK
MCLKs are inserted in back slots 0 and 1 in the main control frame and work in 1+1 standby mode.
The MCLK can be inserted in both SSM-256 frames and SSM-32 frames.
MCLK can generate stratum two clock signal
ME32