Professional Documents
Culture Documents
on in this document is confidential and the property of UOP LLC and must not be disclosed to others or reproduced in any manner or used for any purpose whatsoever without its written permission.
REV DATE BY
402
APVD REV
SHEET
DATE
1
BY APVD
SERVICE
ITEM NO. SURFACE/ITEM-BARE TUBE MTD, EFFECTIVE TRANSFER RATE-FINNED BARE TUBE SERVICE BARE TUBE CLEAN PERFORMANCE DATA - TUBE SIDE
122-MEA-06
m m C (kcal/h)/(m.C) (kcal/h)/(m.C) (kcal/h)/(m.C)
1 2 3 4 5 6 7 8 9
10^6.kcal/h
FORCED NO OF BAYS/ITEM
FLUID NAME
IN
kg/h
OUT 60 70.7 78.6 2.0 18.0 1626 1507 93 26 35755 85 19.3 40.9 2.0 18.0 81.1 18.0 2.03 622.3 0.586 0.109 0.213
kg/m3
10
TOTAL FLUID ENTERING TOTAL FLUID Rel. Mol. Mass DEW POINT POUR POINT BUBBLE POINT FREEZE POINT LATENT HEAT INLET PRESSURE PRESSURE DROP (Allow | Calc) VELOCITY (Allow | Calc) INSIDE FOULING RESISTANCE 0.280
37466 70.7
TEMPERATURE TOTAL VAPOR | Mol. Mass 37466 37233 97 136 VAPOR HCBN VAPOR H2 VAPOR H2O NONCONDENSIBLES LIQUID | Rel. Mol. Mass Water/Other Liq. | Mol. Mass
Mol% H2(V) | Mol% H2S(Tot)
158
C
kg/h kg/h kg/h kg/h kg/h kg/h kg/h
11 12 13 14 15 16 17 18 19 20
C C C C
10.8
DENSITY (V | L) SPECIFIC HEAT (V | L) THERMAL COND (V | L) VISCOSITY (V | L) PERFORMANCE DATA - AIR SIDE
0.0003
h.m.C/kcal
kcal/(kg.C) 21
kcal/(h.m.C) 22
cP
23 24
AIR INLET TEMPERATURE (design dry bulb) AIR FLOW RATE/ITEM AIR FLOW RATE/ITEM MASS VELOCITY (net free area) AIR OUTLET TEMPERATURE AIR SIDE FOULING RESISTANCE 0.0004
50
FACE VELOCITY MINIMUM DESIGN AMBIENT TEMP ALTITUDE STATIC PRESSURE AIR FLOW RATE/FAN 0.1 25
25 26 27 28 29 30 31
DESIGN, MATERIALS, AND CONSTRUCTION DESIGN PRESSURE TEST PRESSURE DESIGN TEMPERATURE MIN. DESIGN METAL TEMP. VACUUM DESIGN PRESSURE VACUUM DESIGN TEMPERATURE TUBE BUNDLE SIZE (W x L) NO./BAY BUNDLES: IN SERIES STRUCTURE MOUNTING PIPEREACK BEAMS (c-c distance) LADDERS, WALKWAYS, PLATFORMS STRUCTURE SURF PREP/COATING HEADER SURF PREP/COATING LOUVER MATERIAL ACTION CONTROL: ACTION TYPE: AUTO OPPOSED MANUAL PARALLEL HEADER TYPE MATERIAL CORROSION ALLOWANCE NO OF PASSES Killed Carbon Steel (Std 3-11)
mm m
kg/cm[g]
HEATING COIL NO OF TUBES TUBE MATERIAL FIN MATERIAL AND TYPE THICKNESS PRESSURE DESIGN CODE STAMP? HEATING FLUID TEMPERATURE (in/out) INLET PRESSURE PRESSURE DROP (allow/calc)
REQUIRED OD
mm
32 33 34 35 mm 36 37
C C kg/cm[a] C
YES
NO FLOW RATE / /
kg/h C kg/cm[g] kg/cm[g] kg/cm[g] C
38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53
YES
NO
NPS
PROJECT SPECIFICATION UOP LLC 25 East Algonquin Road Des Plaines, Illinois 60017-5017 USA Note: The information in this document is confidential and the property of UOP LLC and must not be disclosed to others or reproduced in any manner or used for any purpose whatsoever without its written permission.
REV DATE BY
402
APVD REV
SHEET
DATE
2
BY APVD
ITEM NO.
122-MEA-06 NO./BUNDLE
mm/m
1 2
HEADER (CONTINUED) SLOPE PLUG MATERIAL GASKET MATERIAL NOZZLE INLET OUTLET VENT DRAIN MISC CONN'S: TI CHEMICAL CLEANING MIN. TUBE WALL THICKNESS TUBE MATERIAL OD Killed Carbon Steel (Std 3-11)
mm MIN. WALL THICKNESS mm mm
LENGTH
12.0
m mm
3 4 5 6 7 8
No.
Size (NPS)
9 10 11 12 13
PI
14 15 16 17 18
MECHANICAL EQUIPMENT FAN MANUFACTURER & MODEL NO/BAY DIAMETER ANGLE PITCH ADJUSTMENT BLADE MATERIAL POWER/FAN@DES TEMP MAX ALLOW/CALC TIP SPEED FAN CONTROLS DRIVER TYPE NO/BAY Electric Motor POWER DRIVER CONTROLS - AIR SIDE AIR RECIRCULATION: NONE OVER: SIDE INTERNAL END / MAXIMUM CLOSE POSITIONER LOCKUP LOCKUP BIAS RELAY EXTERNAL LOUVERS: INLET POSITIONER: FROM FROM SUPPLY AIR PRESSURE MAX. MAX. SHIPPING PLOT AREA (W x L) BUNDLE MASS /
m kg
19 rpm
SPEED ENCLOSURE
rpm
SERVICE FACTOR 3
m
20 21
SPEED
m NO OF BLADES
VOLTAGE
415
PHASE
CYCLE /
50
HZ Db(A)
22 23 24
25 26 27 28
TYPE MANUFACTURER & MODEL NO/BAY SERVICE FACTOR SPEED RATIO STRUCTURE YES PEDESTAL NO /1 SUPPORT: VIBRATION SWITCH: ENCLOSURE:
29 30 31 32 33 34 35 36 37
BYPASS
38 39 40 41 42 43 44 45 46 47 48 kg 49 50 51 52 53
DEGREE CONTROL OF OUTLET PROCESS TEMP. MAX COOLING, +/ACTION ON CONTROL SIGNAL FAILURE FAN PITCH: LOUVERS FAN: NONE MINIMUM OPEN
402-0
TZ-402-02-0
PROJECT SPECIFICATION UOP LLC 25 East Algonquin Road Des Plaines, Illinois 60017-5017 USA Note: The information in this document is confidential and the property of UOP LLC and must not be disclosed to others or reproduced in any manner or used for any purpose whatsoever without its written permission.
REV DATE BY
402
APVD REV
SHEET
DATE
3
BY APVD
SERVICE
STRIPPER CONDENSER
1 2 3
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
TOTAL LIQUID Specific Heat Surface Tension Critical Press. Critical Temp
23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
TOTAL LIQUID Specific Heat Surface Tension Critical Press. Critical Temp
40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55
402-0
TZ-402-02-0
PROJECT SPECIFICATION UOP LLC 25 East Algonquin Road Des Plaines, Illinois 60017-5017 USA Note: The information in this document is confidential and the property of UOP LLC and must not be disclosed to others or reproduced in any manner or used for any purpose whatsoever without its written permission.
REV DATE BY
402
APVD REV
SHEET
DATE
4
BY APVD
SERVICE
STRIPPER CONDENSER
1 2 3
NOTES
See UOP Standard Specification 4-13. BUNDLE ARRANGEMENT REQUIREMENTS: None Limit number of tube bundles to 2, 4, 8, 16 2 nth Use even number of tube bundles LINE SIZES Inlet No. Tube side 1 Size, in 8 No. 1 Outlet Size, in 8
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1. Design for hydrogen service per UOP Standard Specification 4-13 Section 4.1. 2. Design for wet H2S service per UOP Standard Specification 4-13 Section 4.2. 3. Provide 3/16" (5 mm) corrosion allowance on headers.
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
402-0
TZ-402-02-0