Project

Job no.

Strathclyde University
Civil Engineering

Calcs for

Start page no./Revision

1
Calcs by Calcs date Checked by Checked date Approved by Approved date

04/03/2014

CONCRETE INDUSTRIAL GROUND FLOOR DESIGN TO TR34 THIRD EDITION


TEDDS calculation version 1.0.05

Slab details Slab description; Slab type; Slab thickness; Reinforcement details Characteristic strength of steel; Fabric reinforcement to bottom of slab; Area of reinforcement in each direction; Percentage of reinforcement provided; Diameter of reinforcement; Depth of nominal cover to reinforcement; Average effective depth of reinforcement; fy = 500 N/mm2 A193 As = 193 mm2/m As_percent = As / h = 0.048% Reinforcement is within recommended limits s = 7 mm cnom = 30 mm d = h - cnom - s = 363 mm slab Fabric reinforced h = 400 mm

Wearing surface h d Reinforced concrete slab Steel fabric reinforcement Slip membrane Sub-base Subgrade

Strength properties for concrete from table 9.1 Characteristic compressive strength (cube); Characteristic compressive strength (cylinder); Mean compressive strength (cylinder); Mean axial tensile strength; Characteristic axial tensile strength (5% fractile); Secant modulus of elasticity; Characteristic flexural strength of concrete; Minimum shear strength of concrete; Subgrade construction Modulus of subgrade reaction; Partial safety factors Bar and fabric reinforcement; Reinforced concrete; Permanent actions; Variable actions; Dynamic actions; Properties of reinforced slabs Allowance for restraint stresses; frest = 1.5 N/mm2 s = 1.15 c = 1.50 G = 1.35 Q = 1.50 D = 1.00 k = 0.050 N/mm3 fcu = 35 N/mm2 fck = 28 N/mm2 fcm = fck + 8 N/mm2 = 36 N/mm2 fctm = 0.3 N/mm2 (fck / 1 N/mm2)2/3 = 2.8 N/mm2 fctk_0.05 = 0.7 fctm = 1.9 N/mm2 Ecm = 22000 N/mm2 (fcm / 10 N/mm2)0.3 = 32 kN/mm2 fctk_fl = min(2, [1 + (200 mm / h)1/2]) fctk_0.05 = 3.3 N/mm2 k1 = 1 + (200 mm / d)1/2 = 1.7 vRd_ct = 0.035 N/mm2 k13/2 (fck / 1 N/mm2)1/2 = 0.4 N/mm2

Project

Job no.

Strathclyde University
Civil Engineering

Calcs for

Start page no./Revision

2
Calcs by Calcs date Checked by Checked date Approved by Approved date

L Negative moment capacity; Positive moment capacity; Poissons ratio; Radius of relative stiffness; Characteristic of system; Point - Internal point load Loading details Number of point loads; Permanent point load; Variable point load; Dynamic point load; Length of loaded area; Width of loaded area;

04/03/2014 Mn = (fctk_fl - frest) h2 / (6 c) = 32.1 kNm/m Mp = min(0.95 As fy d / s, Mn) = 28.9 kNm/m = 0.2 l = [Ecm h3 / (12 (1 2) k)]1/4 = 1.376 m = [3 k / (Ecm h3)]1/4 = 0.519 m-1

N=1 Gk = 0 kN Qk = 500 kN Dk = 0 kN ll = 500 mm lw = 500 mm

ll a lw

Calculate contact radius ratio Equivalent contact radius of single load; Radius ratio; For a / l > 0.2; Check ultimate load capacity of slab Loading applied to slab; Fuls = F = N [(Gk G) + (Qk Q) + (Dk D)] = 750.0 kN PASS - Ultimate capacity of slab is adequate for internal loads Punching shear at the face of the loaded area Design concrete compressive strength (cylinder); Shear factor; Length of perimeter at face of loaded area; Shear stress at face of contact area; Maximum load capacity in punching; fcd = fck / c = 19 N/mm2 k2 = 0.6 [1 - (fck / 250 N/mm2)] = 0.53 u0 = 2 (ll + lw) = 2000 mm vmax_f = 0.5 k2 fcd = 4.973 N/mm2 Pp_max = vmax_f u0 d = 3610.3 kN a = [(ll lw) / ] = 282 mm a / l = 0.205 Pu = 4 (Mp + Mn) / [1 - (a / (3 l))] = 823.3 kN

Ultimate capacity under single internal concentrated load

PASS - Maximum load capacity in punching shear at face of loaded area is adequate for internal loads Punching shear at the critical perimeter Shear factor; Ratio of reinforcement by area in x-direction; Ratio of reinforcement by area in y-direction; Reinforcement ratio; Maximum shear stress at 2d from face of load; Length of perimeter at 2d from face of load; k1 = min(1 + (200 mm / d)0.5, 2) = 1.74 x = As / d = 0.001 y = As / d = 0.001 1 = ( x y) = 0.001 vmax_2d = 0.035 k13/2 (fck / 1 N/mm2)1/2 1 N/mm2 vmax_2d = 0.426 N/mm2 u1 = 2 (ll + lw + 2 d ) = 6562 mm

Project

Job no.

Strathclyde University
Civil Engineering

Calcs for

Start page no./Revision

3
Calcs by Calcs date Checked by Checked date Approved by Approved date

04/03/2014 Pp = vmax_2d u1 d = 1014.5 kN

Maximum load capacity in punching at 2d from face;

PASS - Maximum load capacity in punching shear at 2d from face of loaded area is adequate for internal loads Deflection of the slab Serviceability limit state load; Deflection coefficient; Deflection of the slab; Fsls = N (Gk + Qk + Dk) = 500 kN c = 0.125 = c [Fsls / (k l2)] = 0.66 mm