EQUIPMENT

EQUIPMENT
NO.

V
I
T
A
L

DESCRIPTION

E
S
S
E
N
T
I
A
L

N
O
N
E
S
S
E
N
T

R
E
S
T
A
R
T
I
N
G

LOAD
FACTOR

AT LOAD
FACTOR

POW ER
FACTOR
(PF)
AT LOAD
FACTOR

0.90

0.90

0.90

0.90

EFFICIENCY
ABSORBED
LOAD

NON- MOTOR
RATING

MOTOR
RATING

kVA or HP

kVA

HP

40.50

45.00

kW = ABSORBED LOAD(kVA) * COSp / EFFICIENCY


kVAr = kW * TANp
kW = ABSORBED LOAD(HP) * 0,746 / EFFICIENCY

CONTINUOUS

kW

kVAr

XXX-YY-1

LOAD 1

XXX-YY-2

LOAD 2

9.49

10.55

0.90

0.85

8.96

XXX-YY-3

LOAD 3

18.00

20.00

0.90

0.90

0.88

17.60

XXX-YY-4

LOAD 4

18.00

20.00

0.90

0.88

0.88

15.25

8.23

XXX-YY-5

LOAD 5

54.00

60.00

0.90

0.90

0.90

44.74

21.67

XXX-YY-6

LOAD 6

112.50

125.00

0.90

0.93

0.93

90.21

35.65

XXX-YY-7

LOAD 7

112.50

125.00

0.90

0.93

0.93

XXX-YY-8

LOAD 8

4.50

5.00

0.90

0.85

0.85

XXX-YY-9

LOAD 9

9.00

10.00

0.90

0.90

0.85

10 XXX-YY-10

LOAD 10

9.00

10.00

0.90

0.88

0.85

11 XXX-YY-11

LOAD 11

135.00

150.00

0.90

0.93

0.93

12 XXX-YY-12

LOAD 12

135.00

150.00

0.90

0.93

0.93

13 XXX-YY-13

LOAD 13

4.50

5.00

0.90

0.85

0.85

14 XXX-YY-14

LOAD 14

4.50

5.00

0.90

0.85

15 XXX-YY-15

LOAD 15

4.50

5.00

0.90

16 XXX-YY-16

LOAD 16

4.50

5.00

0.90

17 XXX-YY-17

LOAD 17

4.50

5.00

18 XXX-YY-18

LOAD 18

4.50

19 XXX-YY-19

LOAD 19

20 XXX-YY-20

LOAD 20

21 XXX-YY-21

LOAD 21

22 XXX-YY-22

LOAD 22

23 XXX-YY-23

LOAD 23

24 XXX-YY-24

LOAD 24

25 XXX-YY-25

LOAD 25

26 XXX-YY-26
LOAD 26
MAX NORM RUNNING PLANT LOAD:
( X * CONTINOUS LOAD + Y * INTERMITTENT LOAD )
482.88
439.64 kW
kVA
199.74
kVAr
2
2 1/2
kW ; kVAr; kVA =(kW + kVAr )
COINCIDENCE FACTORS X,Y AND Z SHALL EQUAL
NOTES:
A) ABSORBED LOADS:
- FOR PUMPS, SHAFT LOAD ON DUTY POINT;
- FOR INSTRUMENT., COMPUTERS, COM., AIR COND.,
THE REQ'D LOAD DURING FULL OPER. OF PLANT;
- FOR LIGHTING DURING DARK HOURS;
- FOR W ORKSHOPS, THE AVERAGE TOTAL LOAD
IN NORMAL FULL OPERATION.
PROJECT TITLE:
FIRST ISSUE
REV. LETTER
0
DATE
REV.

215398161.xls.ms_office

1, 0.5, 0.1

INTERMITTENT

kW

kVAr

40.50

19.62

3.95

2.45

108.25

42.78

0.85

3.95

2.45

0.85

0.85

3.95

2.45

0.85

0.90

5.00

9.00

X
X
X

9.00

X
X
X

112.50

22.50

3.95

2.45

0.85

3.95

2.45

0.85

0.85

3.95

2.45

0.90

0.85

0.85

3.95

2.45

10.00

0.90

0.88

0.85

9.00

10.00

0.90

0.88

0.85

18.00

20.00

0.90

0.88

10.00

0.90

0.88

9.00

10.00

0.90

0.88

0.85

13.50

15.00

0.90

0.88

0.90

125.00

0.90

0.93

0.93

0.90

0.90

0.93

B) CONSUMED LOADS:
"CONTINUOUS": ALL LOADS THAT MAY CONTINUOUSLY
BE REQUIRED FOR NORMAL OPERATION, INCLUDING
LIGHTING AND AIR-CONDITIONING.
" INTERMITTENT " THE LOADS REQUIRED FOR
INTERMEDIATE PUMPING, STORAGE, LOADING, ETC. AND
CONVENIENCE RECEPTACLES AND W ORKSHOP LOADS.
PRINCIPLE:
1
2
3
4

kVAr

90.21

35.65

7.63

4.73

108.25

42.78

7.63

4.73

7.63

4.73

9.50

4.62

7.63

4.73

0.85

15.25

9.45

0.85

7.63

4.73

10.30

4.99

23.25

9.19

PEAK LOAD:
( X * CONTINOUS LOAD + Y * INTERMITTENT LOAD + Z * STAN-BY AND SPARES LOAD )TOTAL
506.88 kVA
461.77 kW
209.00 kVAr
2
2 1/2
2
2 1/2
kW ; kVAr; kVA =(kW + kVAr )
kVA =(kW + kVAr )
RESPECTIVELY.

kW

REMARKS

5.55

7.46

25.00

STAND - BY
AND SPARES

90.21

35.65
PF W /O COMPENSATION ( COSp ):

364.41

165.99

150.44

67.50

221.33

PF W / COMPENSATION ( COSp d1 ):
400.44

164.89

239.93

0.91

92.61

REQUIRED CAPACITOR RATING :


kVAr = kW * (TANp - TANp d1 )

0.91
0

"STAND - BY AND SPARES": LOADS REQUIRED


IN EMERGENCIES, SUCH AS FIRE - W ATER
PUMPS. STAND-BY ELECTRIC MOTORS FOR
TURBINE-DRIVEN EQUIPMENT. ALL SPARE
ELECTRIC MOTORS.
CONTR. JOB NO.
CONSIGNEE:
0

UTILITY DATA - ELECTRICAL


DOCUMENT No.
SHEET No

PAGE: 1 OF 1