You are on page 1of 57

1

INDICE

1. INTRODUCCIN --------------------------------------------------------------------------2

2. DESCRIPCIN DEL MBITO GEOGRFICO--------------------------------------4

3. CARACTERSTICAS FISIOGRFICAS Y MORFOMTRICAS--------------12

4. CLCULO DE LAS CURVAS INTENSIDAD PRECIPITACIN -
PERIODO DE RETORNO (I-D-TR)---------------------------------------------------15

5. DETERMINACIN DEL GASTO MXIMO PROBABLE PARA EL
DISEO DE LAS OBRAS DE DRENAJE-------------------------------------------37



















2
1. INTRODUCCIN.
COMO PARTE DE LOS ESTUDIOS PARA LA PROYECCIN DE LA CONSTRUCCIN DE UNA
CARRETERA, (EL CUAL ES EL OBJETIVO PRIMORDIAL DE ESTE TRABAJO) SE ENCUENTRA
EL ESTUDIO HIDROLGICO, YA QUE UNO DE LOS DATOS FUNDAMENTALES CON QUE SE
DEBE DE CONTAR PARA PROYECTAR LAS OBRAS DE DRENAJE, ES EL GASTO DE LA
CORRIENTE ASOCIADO A UN CIERTO PERIODO DE RETORNO, MISMO QUE SE
DETERMINA EN FUNCIN DE LA VIDA TIL DEL PROYECTO Y DEL RIESGO QUE SE PUEDE
ACEPTAR DE QUE FALLE LA OBRA, EL CUAL A SU VEZ ES FUNCIN DE LA IMPORTANCIA
DE STA, DE LOS DAOS QUE OCASIONARA EN CASO DE FALLA Y DEL COSTO DE LA
REPARACIN O RECONSTRUCCIN.

LA DETERMINACIN DEL GASTO DE LA CORRIENTE ES IMPORTANTE PORQUE, SI EL
VALOR QUE SE ADOPTE PARA EL PROYECTO ES EXCESIVO, SE ESTAR
SOBREDISEANDO, GENERANDO UNA INVERSIN INJUSTIFICADA, POR OTRO LADO SI EL
GASTO ES ESCASO, LAS OBRAS NO PERDURARN EL TIEMPO PROYECTADO PARA SU
VIDA TIL.

POR LO ANTERIOR SE VE LA NECESIDAD DE DETERMINAR EL GASTO DE PROYECTO LO
MS ADECUADAMENTE POSIBLE, Y PARA ESTO ES NECESARIO REALIZAR UN ESTUDIO
HIDROLGICO, AMPLIAMENTE TRATADO POR LA RAMA DEL CONOCIMIENTO HUMANO
DEFINIDA COMO HIDROLOGA.

LA HIDROLOGA ES UNA CIENCIA NATURAL QUE ESTUDIA AL AGUA, SU OCURRENCIA, SU
CIRCULACIN Y DISTRIBUCIN EN LA SUPERFICIE TERRESTRE, SUS PROPIEDADES
FSICAS Y QUMICAS Y SU RELACIN EN EL MEDIO AMBIENTE INCLUYENDO A LOS SERES
VIVOS.

EL OBJETIVO DE LA HIDROLOGA APLICADA ES LA DETERMINACIN DE EVENTOS
ANLOGOS A LAS CARGAS DE DISEO EN EL ANLISIS ESTRUCTURAL, LOS
RESULTADOS SON NORMALMENTE ESTIMACIONES CON APROXIMACIN LIMITADA.

EL ANLISIS HIDROLGICO EXHAUSTIVO ES, PUES, EL PRIMER PASO FUNDAMENTAL EN
LA PLANEACIN, DISEO Y OPERACIN DE PROYECTOS HIDRULICOS. EN LA FASE DE
PLANEACIN Y DISEO, EL ANLISIS SE DIRIGE BSICAMENTE A FIJAR LA CAPACIDAD Y
SEGURIDAD DE ESTRUCTURAS HIDRULICAS. LAS DIMENSIONES FSICAS O LA
CAPACIDAD DE CONDUCCIN DE UNA ESTRUCTURA HIDRULICA SE DETERMINA DE
ACUERDO CON LOS VOLMENES Y GASTOS QUE SE DESEEN ALMACENAR, CONTROLAR
O TRANSMITIR.

EN GENERAL EN ESTE ESTUDIO DESCRIBIREMOS LAS CARACTERSTICAS DEL MBITO
GEOGRFICO DEL REA DE INFLUENCIA DEL PUNTO QUE SE EST ANALIZANDO, AS
COMO TAMBIN, LAS CARACTERSTICAS FISIOGRFICAS Y MORFOMTRICAS DE LA
CUENCA, GENERANDO PARA ELLO LAS GRFICAS NECESARIAS PARA LA ADECUADA
INTERPRETACIN DE DATOS, CALCULANDO EL GASTO MXIMO EXTRAORDINARIO PARA
UN PERIODO DE RETORNO DE 5, 10, 25, 50, 100, 500 Y 1000 AOS.

PARA REALIZAR ESTE ESTUDIO FUE NECESARIO RECOPILAR UNA SERIE DE DATOS,
PRINCIPALMENTE DE PRECIPITACIONES, LOS CUALES SON GENERADOS POR LA
COMISIN NACIONAL DEL AGUA (CNA); PARA LA UBICACIN Y DELIMITACIN DE LA
CUENCA SE UTILIZ LA CARTA TOPOGRFICA MINATITLN E13B33 CON ESCALA 1:50 000
Y CURVAS DE NIVEL A CADA 20 METROS, EDITADA POR EL INSTITUTO NACIONAL DE






3
ESTADSTICA GEOGRAFA E INFORMTICA (INEGI); NOS APOYAMOS TAMBIN EN EL
LIBRO DE ISOYETAS PUBLICADO POR LA DIRECCIN GENERAL DE SERVICIOS TCNICOS
DE LA SECRETARA DE COMUNICACIONES Y TRANSPORTES (SCT).

EL CLCULO DEL GASTO SE REALIZ POR TRES MTODOS, UNO EMPRICO (MTODO DE
CREAGER) EN EL CUAL NO SE REQUIEREN DATOS DE PRECIPITACIONES, ESTE MTODO
SE BASA PRINCIPALMENTE EN EL TAMAO DE LA CUENCA Y LA REGIN HIDROLGICA
EN LA QUE SE ENCUENTRA; SE UTILIZ TAMBIN UN MTODO SEMIEMPRICO (MTODO
RACIONAL) EN ESTE MTODO SI SE REQUIEREN DATOS DE PRECIPITACIONES Y PARA LA
DETERMINACIN DE LA INTENSIDAD DE LLUVIA NOS APOYAMOS EN LAS ISOYETAS
EDITADAS POR LA SCT LAS CUALES SIRVIERON DE BASE PARA CALCULAR Y GRAFICAR
LAS CURVAS INTENSIDAD-DURACIN-PERIODO DE RETORNO (CURVAS I-D-TR) CON
ELLAS SE OBTUVIERON LAS INTENSIDADES DE LLUVIA PARA DIFERENTES PERIODOS DE
RETORNO, CON ESTAS INTENSIDADES DE LLUVIA SE HIZO EL CLCULO DE LOS GASTOS
MXIMOS EXTRAORDINARIOS PARA CADA PERIODO DE RETORNO; POR LTIMO
UTILIZAMOS EL MTODO DE VEN TE CHOW.










































4
2. DESCRIPCIN DEL MBITO GEOGRFICO.
LOCALIZACIN.
EL ARROYO EL PEN SE ENCUENTRA UBICADO A 2.5 KM DEL SUR DE LA CABECERA
MUNICIPAL DE MINATITLN, COLIMA; INMERSO DENTRO DE LA REGIN HIDROLGICA
ADMINISTRATIVA DENOMINADA COMO LERMA-SANTIAGO-PACFICO, EN LA REGIN
HIDROLGICA No. 15 NOMBRADA COMO COSTA DE JALISCO, EN EL LMITE ESTE DE LA
CUENCA MARABASCO. DICHO CUERPO INICIA EN EL CERRO DENOMINADO EL PEN, EN
LA ELEVACIN 1920 M.S.N.M Y SU TRAYECTO DE APROXIMADAMENTE 11.70 KM. UNA
SERIE DE ARROYOS INTERMITENTES SIN NOMBRE DE HASTA TERCER ORDEN VIERTEN
SUS AGUAS AL CAUCE PRINCIPAL, EL CUAL POSTERIORMENTE SE UNE AL RO
MINATITLN O MARABASCO.
UBICACIN GEOGRFICA
R
CUADRO 1.1


COORDENADAS GEOGRFICAS EXTREMAS AL NORTE 1930', AL SUR 1915' DE LATITUD NORTE; AL ESTE 10353',
AL OESTE 10414' DE LONGITUD OESTE.

PORCENTAJE TERRITORIAL EL MUNICIPIO DE MINATITLN REPRESENTA EL 7.30% DE LA SUPERFICIE
DEL ESTADO.

COLINDANCIAS EL MUNICIPIO DE MINATITLN COLINDA AL NORTE CON EL ESTADO DE
JALISCO; AL ESTE CON EL ESTADO DE JALISCO Y LOS MUNICIPIOS DE
COMALA Y VILLA DE LVAREZ; AL SUR CON LOS MUNICIPIOS DE
VILLA DE LVAREZ, COQUIMATLN
Y MANZANILLO; AL OESTE CON EL MUNICIPIO DE MANZANILLO Y EL
ESTADO DE JALISCO.



FUENTE: INEGI. Carta Topogrfica, 1:50 000. (segunda edicin).
INEGI. Marco Geoestadstico, 2000.




LOCALIDADES PRINCIPALES
R

CUADRO 1.2


NOMBRE LATITUD NORTE LONGITUD
OESTE
ALTITUD
(a) Grados Minutos Grados Minutos (msnm)
(b) (b) (b)



MINATITLN
a

19 23 104 03 640
BENITO JUREZ DE PEA COLORADA 19 21

104 05 610





a
Cabecera Municipal.

msnm: metros sobre el nivel del mar.
FUENTE: (a) INEGI. Colima. XII Censo General de Poblacin y Vivienda, 2000. Tabulados
Bsicos.

(b) INEGI. Carta Topogrfica, 1:50 000. (segunda edicin).







5

ELEVACIONES PRINCIPALES
R

CUADRO 1.3


NOMBRE LATITUD NORTE LONGITUD
OESTE
ALTITUD
Grados Minutos Grados Minutos (msnm)



SIERRA DE MANANTLN 19 25

103 54 2 420
CERRO GRANDE 19 26

103 58 2 120
CERRO EL PEN 19 20

104 02 2 020
CERRO COPALES 19 22

104 01 1 700
CERRO LA OTATERA 19 23

104 01 1 700
CERRO LA PALMA 19 26

104 04 1 280



msnm: metros sobre el nivel del mar.
FUENTE: INEGI. Carta Topogrfica, 1:50 000. (segunda
edicin).



FISIOGRAFA
R

CUADRO
1.4


PROVINCIA SUBPROVINCIA SISTEMAS DE
TOPOFORMAS
% DE LA
SUPERFICIE
CLAVE NOMBRE CLAVE NOMBRE CLAVE NOMBRE MUNICIPAL



XII SIERRA MADRE DEL
SUR
65 SIERRAS DE LA
COSTA

DE JALISCO Y
COLIMA
100 SIERRA 80.54
600 VALLE 10.26
602 VALLE CON
LOMEROS
9.20



FUENTE: CGSNEGI. Carta Fisiogrfica,
1:1 000 000.













6
CLIMAS
R
CUADRO 1.6


TIPO O SUBTIPO SMBOLO % DE LA SUPERFICIE
MUNICIPAL



CLIDO SUBHMEDO CON LLUVIAS EN VERANO,
DE MAYOR HUMEDAD A(w2) 25.23

CLIDO SUBHMEDO CON LLUVIAS EN VERANO,
DE HUEMDAD MEDIA A(w1) 22.29

CLIDO SUBHMEDO CON LLUVIAS EN VERANO,
DE MENOR HUMEDAD A(w0) 5.64

SEMICLIDO SUBHMEDO CON LLUVIAS EN VERANO
DE MAYOR HUMEDAD ACw2 31.34

SEMICLIDO SUBHMEDO CON LLUVIAS EN VERANO
DE HUEMDAD MEDIA ACw1 4.80

TEMPLADO SUBHMEDO CON LLUVIAS EN VERANO,
DE MAYOR HUMEDAD C(w2) 10.70

GEOLOGA
R

CUADRO 1.5


ERA PERIODO ROCA O SUELO UNIDAD LITOLGICA % DE LA
SUPERFICIE
CLAVE NOMBRE CLAVE NOMBRE CLAVE NOMBRE CLAVE NOMBRE MUNICIPAL







C CENOZOICO Q CUATERNARIO Su SUELO (al) ALUVIAL 4.65

T TERCIARIO Ie GNEA
EXTRUSIVA
(a) ANDESITA 3.31
(da) DACITA 0.15

S SEDIMENTARIA (ar-cg) ARENISCA-
CONGLOMERADO
2.05

T-Q TERCIARIO


CUATERNARIO Ie GNEA
EXTRUSIVA
(bvi) BRECHA VOLCNICA 0.59

M MESOZOICO K CRETCICO Ii GNEA
INTRUSIVA
(gr) GRANITO 54.65

S SEDIMENTARIA (cz) CALIZA 21.35

Vc
VOLCANOCLSTIC
A
(vc) VOLCANOCLSTICA 9.67
(vs)
VOLCANOSEDIMENTARIA
3.58





FUENTE: INEGI. Carta Geolgica, 1:250 000.







7


FUENTE: CGSNEGI. Carta de Climas, 1:1 000 000.


ESTACIONES METEOROLGICAS
R

CUADRO
1.6.1


CLAVE ESTACIN LATITUD NORTE LONGITUD OESTE ALTITUD
Grado
s
Minuto
s
Segundo
s
Grado
s
Minuto
s
Segundo
s
(msnm)



06-108 MINATITLN 19 22 00 104 04 00 625

06-00P EL TERRERO 19 26 46

103 57 05 2 210



msnm: metros sobre el nivel del mar.


FUENTE: CNA. Registro de Temperatura y Precipitacin.
Indito.









TEMPERATURA MEDIA
ANUAL
R

CUADRO 1.6.2
(Grados centgrados)


ESTACIN PERIODO TEMPERATURA TEMPERATURA DEL TEMPERATURA DEL
PROMEDIO AO MS FRO AO MS CALUROSO



MINATITLN De 1965 a
2001
23.1 21.3 26.4

EL TERRERO De 1987 a
1999
14.2 12.7 15.5



FUENTE: CNA. Registro Mensual de Temperatura Media en
o
C. Indito.









8





PRECIPITACIN TOTAL ANUAL
R

CUADRO 1.6.3
(Milmetros)


ESTACIN PERIODO PRECIPITACIN PRECIPITACIN DEL PRECIPITACIN DEL
PROMEDIO AO MS SECO AO MS LLUVIOSO



MINATITLN De 1961 a
2001
1 591.5 920.7 2 747.0

EL TERRERO De 1991 a
1999
1 267.2 791.6 2 077.5



FUENTE: CNA. Registro Mensual de Precipitacin Pluvial en mm. Indito.



PRECIPITACIN TOTAL
MENSUAL
R

CUADRO
1.6.3.1
(Milmetros)


ESTACIN PERIODO MES
CONCEPTO E F M A M J J A S O N D



MINATITN 2001 0.0 0.0 43.5 0.0 0.0 171.9 268.5 235.3 396.1 116.2 6.9 0.0
PROMEDIO De 1961 a 2001 21.4 7.0 7.3 2.5 21.8 213.7 351.5 383.7 385.8 148.0 29.8 19.0
AO MS SECO 2000 0.0 0.0 0.0 0.0 59.7 5.1 228.0 326.9 237.7 33.3 24.0 6.0
AO MS LLUVIOSO 1975 9.0 0.0 0.0 0.0 20.0 356.0 642.5 878.5 437.5 398.5 5.0 0.0

EL TERRERO 1999 0.0 99.6 0.0 0.0 12.0 268.6 425.0 376.1 485.3 13.5 2.0 0.0
PROMEDIO De 1991 a 1999 98.6 28.4 0.0 1.1 16.4 162.4 244.9 261.8 189.0 180.5 59.1 25.0
AO MS SECO 1995 0.0 19.0 0.0 0.0 18.0 279.4 98.8 128.3 197.3 8.3 24.5 18.0
AO MS LLUVIOSO 1992 582.5 45.0 0.0 7.0 71.0 137.0 303.0 177.0 171.0 441.0 23.0 120.0



FUENTE: CNA. Registro Mensual de Precipitacin Pluvial en mm.
Indito.








9


CORRIENTES DE AGUA
R
CUADRO
1.7.1


NOMBRE UBICACIN NOMBRE UBICACIN



MINATITLN RH15Ab LAS MULAS RH15Ab
JULUAPAN RH16Ba EL CONVENTO RH15Ab
PALO VERDE RH15Ab EL NOGAL RH15Ab
LOS CHICOS RH15Ab JUANILLOS RH16Ba
LAS TRUCHAS RH15Ab ASTILLERO RH16Ba
EL PEN RH15Ab EL BONETE RH15Ab
TO NACHO RH15Ab HONDO RH15Ab
EL RINCN RH15Ab AGUA FRA RH15Ab
LA SIDRA RH15Ab CHICAL RH16Ba
LOS GRANADILLOS RH15Ab EL TIGRE RH16Ba
LA MESA RH15Ab



FUENTE: CGSNEGI. Carta Hidrolgica de Aguas Superficiales, 1:250 000.

AGRICULTURA Y
VEGETACIN
R

CUADRO
1.8






10
















USO POTENCIAL DE LA
TIERRA
R

CUADRO 1.9



CONCEPTO NOMBRE CIENTFICO NOMBRE LOCAL UTILIDAD



AGRICULTURA
5.26% DE LA SUPERFICIE MUNICIPAL Zea mays MAZ COMESTIBLE
Coffea arabica CAFETO INDUSTRIAL

PASTIZAL
3.89% DE LA SUPERFICIE MUNICIPAL Acacia sp. SUBN FORRAJE

BOSQUE
54.81% DE LA SUPERFICIE MUNICIPAL Quercus magnoliifolia ENCINO NOPIS MADERA
Pinus michoacana PINO ESCOBETN MADERA

SELVA
35.89% DE LA SUPERFICIE MUNICIPAL Brosimun alicastrum CAPOMO MADERA

Bursera sp. COPAL MADERA
Guazuma ulmifolia GUCIMA FORRAJE

OTRO
0.15% DE LA SUPERFICIE MUNICIPAL



NOTA: Slo se mencionan algunas especies tiles.
FUENTE: INEGI. Carta de Uso del Suelo y Vegetacin, 1:250 000.






11

CONCEPTO CLASE O SUBCLASE % DE LA SUPERFICIE
CLAVE DESCRIPCIN MUNICIPAL



USO AGRICOLA A2.2 DE TRACCIN ANIMAL CONTINUA 4.04
A3 DE TRACCIN ANIMAL ESTACIONAL 5.55
A5 MANUAL ESTACIONAL 11.40
A6 NO APTAS PARA LA AGRICULTURA 79.01

USO PECUARIO P3 PARA EL APROVECHAMIENTO DE LA VEGETACIN NATURAL
DIFERENTE DEL PASTIZAL 20.99
P4 PARA EL APROVECHAMIENTO DE LA VEGETACIN NATURAL NICAMENTE
POR EL GANADO CAPRINO 78.86
P5 NO APTAS PARA USO PECUARIO 0.15



FUENTE: CGSNEGI. Carta de Uso Potencial, Agricultura, 1:1 000 000.
CGSNEGI. Carta de Uso Potencial, Ganadera, 1:1 000 000.















3. CARACTERSTICAS FISIOGRFICAS Y MORFOMTRICAS







12
PARA DETERMINAR LAS CARACTERSTICAS MORFOMTRICAS DE LA CUENCA SE
EMPLE LA CARTA TOPOGRFICA MINATITLN E13B33, SE DELIMIT LA CUENCA POR
MEDIO DEL PARTEAGUAS, DEFINIDO COMO UNA LNEA IMAGINARIA QUE SIRVE DE
FRONTERA ENTRE UNA CUENCA Y OTRA. UNA VEZ DELIMITADA LA CUENCA SE
TRAZARON LOS ESCURRIMIENTOS SUPERFICIALES EXISTENTES EN LA CUENCA,
POSTERIORMENTE SE SELECCION EL CAUCE PRINCIPAL, EL CUAL GENERALMENTE ES
EL ESCURRIMIENTO SUPERFICIAL DE MAYOR LONGITUD Y DE MAYOR ORDEN, POR
LTIMO SE ETIQUETA EL RDEN DE CADA ESCURRIMIENTO SUPERFICIAL.
A CONTINUACIN SE PRESENTA GRFICAMENTE LA CUENCA DELIMITADA Y LOS
ESCURRIMIENTOS INCLUYENDO EL CAUCE PRINCIPAL; EN LA FIGURA SE MUESTRA EL
CAUCE PRINCIPAL EN COLOR AZUL, LOS ESCURRIMIENTOS EN COLOR NEGRO, EL
ORDEN DEL ESCURRIMIENTO CON NERO ARBIGO Y EL PARTEAGUAS EN COLOR ROJO.




MICROCUENCA: ES UNA ZONA DE LA SUPERFICIE TERRESTRE QUE FORMA
PARTE DE UNA CUENCA EN DONDE LAS GOTAS DE LLUVIA QUE CAEN SOBRE
ELLA TIENDEN A SER DRENADAS POR EL SISTEMA DE CORRIENTES HACIA UN
MISMO PUNTO DE SALIDA.

REA DE LA CUENCA
1
3
0
0
1
4
0
0
1
5
0
0
1
2
0
0
1
1
0
0
MICROCUENCA 1
MICROCUENCA 2
MICROCUENCA 3
MICROCUENCA 4






13

EL REA DE LA CUENCA (A) ES QUIZ EL PARMETRO MS IMPORTANTE, SIENDO
DETERMINANTE DE LA ESCALA DE VARIOS FENMENOS HIDROLGICOS TALES COMO,
EL VOLUMEN DE AGUA QUE INGRESA POR PRECIPITACIN, LA MAGNITUD DE LOS
CAUDALES ETC., EL REA DE LA CUENCA SE DEFINE COMO LA PROYECCIN
HORIZONTAL DE LA SUPERFICIE DE LA MISMA DELIMITADA POR EL PARTEAGUAS Y SE
PUEDE MEDIR DIRECTAMENTE DE LA CARTA TOPOGRFICA, EN ESTE CASO EL REA DE
LAS MICROCUENCAS POR DRENAR, SE MUESTRA GRFICAMENTE EN LA FIGURA DE
ARRIBA Y ES:
MICROCUENCA 1 A=0.227 KM
2
MICROCUENCA 2 A=0.273 KM
2

MICROCUENCA 3 A=0.256 KM
2

MICROCUENCA 4 A=0.447 KM
2



PERMETRO DE LA CUENCA.
EL PERMETRO DE LAS MICROCUENCAS (P) ES LA LONGITUD DEL PARTEAGUAS QUE
DELIMITA CADA MICROCUENCA Y ES:
MICROCUENCA 1 P=2443.98 KM

MICROCUENCA 2 P=3774.75 KM
MICROCUENCA 3 P=3260.96 KM
MICROCUENCA 4 P=3928.23 KM

LONGITUD DEL ESCURRIMIENTO.
ESCURRIMIENTO 1 L=1105.74 KM

ESCURRIMIENTO 2 L=1691.39 KM
ESCURRIMIENTO 3 L=1334.82 KM
ESCURRIMIENTO 4 L=1625.45 KM


PENDIENTE DEL ESCURRIMIENTO
PARA CALCULAR LA PENDIENTE DEL ESCURRIMIENTO EXISTEN VARIOS MTODOS: EL
MTODO ARITMTICO, EL MTODO DE LAS REAS Y EL MTODO DE TAYLOR; PARA ESTE
ESTUDIO UTILIZAREMOS EL MTODO ARITMTICO.
ESCURRIMIENTO 1
COTA 1 = 1240.00
COTA 2 = 1060.00
LONG. =1105.74
PENDIENTE = 0.163

ESCURRIMIENTO 2 S=1691.39 KM
COTA 1 = 1500.00
COTA 2 = 1059.00
LONG. =1691.39
PENDIENTE = 0.260


ESCURRIMIENTO 3 S=1334.82 KM
COTA 1 = 1360.00






14
COTA 2 = 1055.00
LONG. = 1334.82
PENDIENTE = 0.228

ESCURRIMIENTO 4 S=1625.45 KM
COTA 1 = 1490.00
COTA 2 = 1060.00
LONG. = 1625.00
PENDIENTE = 0.265



































4.- CLCULO DE LAS CURVAS INTENSIDAD PRECIPITACIN - PERIODO
DE RETORNO (I-D-TR)







15
EL CLCULO DE LAS CURVAS INTENSIDAD PRECIPITACIN PERIODO DE RETORNO ES
DE VITAL IMPORTANCIA EN UN ESTUDIO HIDROLGICO, YA QUE CON LA INFORMACIN
QUE SE OBTIENE DE ELLAS, SE CALCULAN POR DISTINTOS MTODOS LOS GASTOS DE
DISEO PARA LAS ESTRUCTURAS DE OBRAS HIDRULICAS, EN LAS CUALES EL GRADO
PTIMO DE SEGURIDAD DEPENDE DE SU COSTO Y DEL COSTO DE LAS PRDIDAS DE
UNA FALLA. UNA VEZ CALCULADAS LAS CURVAS I D TR SE PUEDE GENERAR PARA EL
GRUPO DE DATOS EXISTENTES UNA ECUACIN O UNA FRMULA GENERAL PARA ESE
GRUPO DE DATOS PARA CALCULAR LAS INTENSIDADES DE LLUVIA PARA UN PERIODO DE
RETORNO DETERMINADO Y CIERTA DURACIN.
DENTRO DE LOS DATOS NECESARIOS PARA INICIAR CON EL CLCULO DE LAS CURVAS I
D TR SON LOS DATOS OBTENIDOS DE UN PLUVIGRAFO, LOS CUALES TIENEN UN
MECANISMO PARA PRODUCIR UN REGISTRO CONTINUO DE PRECIPITACIN;
LAMENTABLEMENTE EN LA ESTACIN CLIMATOLGICA DE INFLUENCIA PARA EL
ESTUDIO NO SE CUENTA CON ESTE DISPOSITIVO, POR LO CUAL, ES NECESARIO
RECURRIR A FUNCIONES DE DISTRIBUCIN DE PROBABILIDAD. EN LA ESTADSTICA
EXISTEN DECENAS DE FUNCIONES DE DISTRIBUCIN DE PROBABILIDAD TERICA, LAS
MS UTILIZADAS EN HIDROLOGA SON LAS SIGUIENTES:
A) NORMAL
B) LOGNORMAL
C) PEARSON III
D) GUMBEL
E) FUNCIONES PARA DOS POBLACIONES
LAS FUNCIONES NORMAL Y LOGNORMAL SON GENERALMENTE APROPIADAS PARA
VARIABLES ALEATORIAS QUE CUBREN TODO EL RANGO DE VALORES DE LOS
RESULTADOS POSIBLES DEL EXPERIMENTO BAJO ANLISIS; LAS FUNCIONES GUMBEL SE
DESARROLLARON PARA LOS ANLISIS DE LOS VALORES EXTERMOS DE DICHOS
RESULTADOS (COMO GASTOS MXIMOS O MNIMOS ANUALES); LA FUNCIN PEARSON III
OCUPA UN LUGAR INTERMEDIO.
PARA ESTE TRABAJ O SE REALIZARN LOS CLCULOS BAJ O LA FUNCIN DE
PROBABILIDAD GUMBEL.





DATOS DE LA ESTACIN CLIMATOLGICA MINATITLAN.






16
CON LOS DATOS RECOPILADOS DE LA ESTACIN CLIMATOLGICA MINATITLN (VER
ANEXO N); Y CON LAS PRECIPITACIONES MXIMAS REGISTRADAS DE CADA AO SE
CONSTRUY LA SIGUIENTE TABLA:
ESTACIN CLIMATOLGICA MINATITLN
DATO AO P.MAX (P.MAX-PROM) (P.MAX-PROM)
2

1 1958 70.50 -40.33 1626.890
2 1959 64.00 -46.83 2193.492
3 1960 62.00 -48.83 2384.831
4 1961 67.00 -43.83 1921.483
5 1962 93.00 -17.83 318.077
6 1963 89.00 -21.83 476.755
7 1964 90.50 -20.33 413.501
8 1965 90.00 -20.83 434.086
9 1966 69.00 -41.83 1750.144
10 1967 89.00 -21.83 476.755
11 1968 212.00 101.17 10234.412
12 1969 210.00 99.17 9833.751
13 1970 90.00 -20.83 434.086
14 1971 96.00 -14.83 220.069
15 1972 79.00 -31.83 1013.450
16 1973 69.00 -41.83 1750.144
17 1974 115.00 4.17 17.349
18 1975 78.00 -32.83 1078.119
19 1976 87.50 -23.33 544.509
20 1977 72.00 -38.83 1508.136
21 1978 70.00 -40.83 1667.475
22 1979 124.00 13.17 173.324
23 1980 53.00 -57.83 3344.856
24 1981 67.50 -43.33 1877.899
25 1982 48.00 -62.83 3948.203
26 1983 94.00 -16.83 283.408
27 1984 86.80 -24.03 577.668
28 1985 79.40 -31.43 988.142
29 1986 65.10 -45.73 2091.665
30 1987 215.20 104.37 10892.110
31 1988 150.20 39.37 1549.625
32 1989 88.40 -22.43 503.317
33 1990 94.90 -15.93 253.916
34 1991 68.40 -42.43 1800.706
35 1992 110.20 -0.63 0.403
36 1993 55.30 -55.53 3084.106
37 1994 78.60 -32.23 1039.078
38 1995 260.00 149.17 22250.279
39 1996 178.60 67.77 4592.132
40 1997 100.00 -10.83 117.391
41 1998 101.00 -9.83 96.722
42 1999 248.90 138.07 19062.020






17
43 2000 167.01 56.18 3155.661
44 2001 83.40 -27.43 752.664
45 2002 102.30 -8.53 72.842
46 2003 127.30 16.47 271.105
47 2004 100.00 -10.83 117.391
48 2005 121.90 11.07 122.440
49 2006 143.10 32.27 1041.048
50 2007 130.80 19.97 398.612
51 2008 86.10 -24.73 611.807
52 2009 78.50 -32.33 1045.535
53 2010 83.00 -27.83 774.772
54 2011 404.50 293.67 86239.292
55 2012 138.00 27.17 737.952

SUMATORIAS 6095.91 214165.608

COMO SE OBSERVA EN LA TABLA EL NMERO DE DATOS REGISTRADOS EN LA ESTACIN
CLIMATOLGICA ES DE 55 DATOS; CALCULANDO LA PRECIPITACIN MEDIA (P
prom
),
TENEMOS: P
prom
= P
max
/ N;
DONDE
P
prom
= PRECIPITACIN MEDIA
Pmax = SUMATORIA DE PRECIPITACIONES MXIMAS
N = NMERO DE DATOS

APLICANDO LA FRMULA: P
prom
= Pmax / N; Y SUSTITUYENDO VALORES
P
prom
= 6095.91 / 55
P
prom
=110.83

LUEGO SE CALCULA LA DESVIACIN ESTANDAR APLICANDO LA SIGUIENTE FRMULA: S
= ( (P
i
- P
prom
)
2
/(N-1))
1/2


DONDE
S = DESVIACIN ESTANDAR
P
i
= PRECIPITACIN MXIMA DEL AO i
P
prom
= PRECIPITACIN MEDIA

APLICANDO LA FRMULA: S = ( (P
i
- P
prom
)
2
)
1/2
; Y SUSTITUYENDO VALORES DE LA TABLA
ANTERIOR
S = (214165.608 /54)
1/2

S = 62.98
LUEGO APLICANDO LA DISTRIBUCIN DE PROBABILIDAD GUMBEL PODEMOS CALCULAR
LA PRECIPITACIN EN 24 HORAS Y EN 1 HORA PARA UN PERIODO DE RETORNO TR
CON LAS SIGUIENTES FRMULAS:
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
TR
60
= (R) (P
TR
1440
)
P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60







18


DONDE:
P
TR
1440
= PRECIPITACIN MXIMA EN 24 HORAS PARA UN PERIODO DE RETORNO DE TR
EN AOS
= PARMETRO DE UBICACIN DADO POR LA FRMULA =
y
/ S
= PARMETRO DE FORMA DADO POR LA FRMULA = P
prom
-
y
/

y
Y

y
= PARMETROS ESTADSTICOS.
TR = PERIODO DE RETORNO.
R = FACTOR DE DEPENDE DE LA REGIN HIDROLGICA EN ESTE CASO R=0.2832


PARA DETERMINAR LOS VALORES DE
y Y
y NOS APOYAMOS EN LA TABLA 9.6 DEL LIBRO
FUNDAMENTOS DE HIDROLOGA DE APARICIO MIJARES, LA CUAL ES LA SIGUIENTE:



PARMETROS ESTADSTICOS
n
y

y

10 0.4952 0.9496
15 0.5128 1.0206
20 0.5236 1.0628
25 0.5309 1.0914
30 0.5362 1.1124

35 0.5403 1.1285
40 0.5436 1.1413
45 0.5463 1.1518
50 0.5485 1.1607
55 0.5504 1.1682

60 0.5521 1.1747
65 0.5535 1.1803
70 0.5548 1.1854
75 0.5559 1.1898
80 0.5569 1.1938

85 0.5578 1.1974
90 0.5586 1.2007
95 0.5593 1.2037
100 0.5600 1.2065



APLICANDO LAS FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
=
y
/ S; =1.1682/62.98; =0.0185
= P
prom
(
y
/ ); = 110.83 (0.5504/0.0185); = 110.83 29.75; =81.08






19

CON ESTAS FRMULAS PODEMOS CALCULAR LAS CURVAS I-D-TR, LAS CUALES SE CALCULARN DE
ACUERDO A LOS TRMINOS DE REFERENCIA PARA PERIODOS DE RETORNO DE 5, 10, 25, 50, 100,
500 Y 1000 AOS

CLCULO DE LA CURVA I-D-TR PARA UN PERIODO DE RETORNO DE 2 AOS.
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
2
1440
= 81.08 (1/0.0185) ln(ln(2/(2-1))
P
2
1440
= 81.08 (54.05) (-0.367)
P
2
1440
= 81.08 +19.82
P
2
1440
= 100.90

P
2
60
= (R) (P
2
1440
)
P
2
60
= (0.2832) (100.90)
P
2
60
= 28.57

LUEGO APLICANDO LA FRMULA P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60
PODEMOS CLCULAR
LA PRECIPITACIN PARA CIERTA DURACIN; EN ESTE CASO CALCULAREMOS PRECIPITACIONES
PARA CADA 2 MIN, LO CUAL NOS GENERA LA SIGUIENTE TABLA:

CLCULO CURVA I-D-TR
PERIODO DE RETORNO EN AOS 2
PRECIPITACIN EN 60 MIN 28.57
DURACIN (MIN) PRECIPITACIN INTENSIDAD
2 4.07 122.17
4 7.55 113.29
6 9.89 98.86
8 11.69 87.69
10 13.18 79.10
12 14.47 72.33
14 15.60 66.85
16 16.61 62.30
18 17.54 58.46
20 18.39 55.17
22 19.18 52.30
24 19.91 49.79
26 20.61 47.55
28 21.26 45.56
30 21.88 43.76
32 22.47 42.13
34 23.03 40.64






20
36 23.57 39.28
38 24.08 38.02
40 24.58 36.87
42 25.06 35.79
44 25.52 34.79
46 25.96 33.86
48 26.39 32.99
50 26.81 32.17
52 27.21 31.40
54 27.61 30.68
56 27.99 29.99
58 28.36 29.34
60 28.73 28.73
62 29.08 28.14
64 29.43 27.59
66 29.77 27.06
68 30.10 26.56
70 30.42 26.07
72 30.74 25.61
74 31.04 25.17
76 31.35 24.75
78 31.65 24.34
80 31.94 23.95
82 32.22 23.58
84 32.51 23.22
86 32.78 22.87
88 33.05 22.54
90 33.32 22.21
92 33.58 21.90
94 33.84 21.60
96 34.10 21.31
98 34.35 21.03
100 34.59 20.76
102 34.83 20.49
104 35.07 20.23
106 35.31 19.99
108 35.54 19.75
110 35.77 19.51
112 36.00 19.28






21
114 36.22 19.06
116 36.44 18.85
118 36.66 18.64
120 36.87 18.44


CLCULO DE LA CURVA I-D-TR PARA UN PERIODO DE RETORNO DE 2 AOS.
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
5
1440
= 81.08 (1/0.0185) ln(ln(5/(5-1))
P
5
1440
= 81.08 (54.05) (-1.50)
P
5
1440
= 81.08 +81.07
P
5
1440
= 162.15

P
5
60
= (R) (P
5
1440
)
P
5
60
= (0.2832) (162.15)
P
5
60
= 45.92

LUEGO APLICANDO LA FRMULA P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60
PODEMOS CLCULAR
LA PRECIPITACIN PARA CIERTA DURACIN; EN ESTE CASO CALCULAREMOS PRECIPITACIONES
PARA CADA 2 MIN, LO CUAL NOS GENERA LA SIGUIENTE TABLA:

CLCULO CURVA I-D-TR
PERIODO DE RETORNO EN AOS 5
PRECIPITACIN EN 60 MIN 45.92
DURACIN (MIN) PRECIPITACIN INTENSIDAD
2 8.64 259.18
4 16.02 240.34
6 20.97 209.73
8 24.80 186.02
10 27.97 167.81
12 30.69 153.45
14 33.09 141.81
16 35.24 132.17
18 37.21 124.02
20 39.01 117.03
22 40.68 110.95
24 42.25 105.61
26 43.71 100.88
28 45.10 96.64
30 46.41 92.82
32 47.66 89.37






22
34 48.85 86.21
36 49.99 83.32
38 51.09 80.66
40 52.14 78.21
42 53.15 75.93
44 54.13 73.81
46 55.07 71.83
48 55.99 69.98
50 56.87 68.25
52 57.73 66.62
54 58.57 65.08
56 59.38 63.62
58 60.17 62.25
60 60.94 60.94
62 61.69 59.70
64 62.43 58.53
66 63.14 57.40
68 63.85 56.33
70 64.53 55.31
72 65.20 54.33
74 65.86 53.40
76 66.50 52.50
78 67.13 51.64
80 67.75 50.81
82 68.36 50.02
84 68.96 49.26
86 69.54 48.52
88 70.12 47.81
89 70.40 47.46
90 70.69 47.12
92 71.24 46.46
94 71.79 45.82
96 72.33 45.21
98 72.86 44.61
100 73.38 44.03
102 73.90 43.47
104 74.41 42.93
106 74.91 42.40
108 75.40 41.89






23














CLCULO DE LA CURVA I-D-TR PARA UN PERIODO DE RETORNO DE 10 AOS.
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
10
1440
= 81.08 (1/0.0185) ln(ln(10/(10-1))
P
10
1440
= 81.08 (54.05) (-2.250)
P
10
1440
= 81.08 +121.63
P
10
1440
= 202.71

P
10
60
= (R) (P
10
1440
)
P
10
60
= (0.2832) (202.71)
P
10
60
= 57.41

LUEGO APLICANDO LA FRMULA P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60
PODEMOS
CLCULAR LA PRECIPITACIN PARA CIERTA DURACIN; EN ESTE CASO CALCULAREMOS
PRECIPITACIONES PARA CADA 2 MIN, LO CUAL NOS GENERA LA SIGUIENTE TABLA:

CLCULO CURVA I-D-TR
PERIODO DE RETORNO EN AOS 10
PRECIPITACIN EN 60 MIN 57.41
DURACIN (MIN) PRECIPITACIN INTENSIDAD
2 12.78 383.43
4 23.70 355.56
6 31.03 310.28
8 36.69 275.20
10 41.38 248.27
12 45.40 227.02
14 48.95 209.80
16 52.14 195.53
18 55.04 183.48
20 57.71 173.13
22 60.19 164.15
24 62.50 156.25
110 75.89 41.39
112 76.36 40.91
114 76.84 40.44
116 77.31 39.99
118 77.77 39.54
120 78.22 39.11






24
26 64.67 149.24
28 66.72 142.97
30 68.66 137.33
32 70.51 132.21
34 72.27 127.54
36 73.96 123.27
38 75.58 119.34
40 77.14 115.70
42 78.63 112.33
44 80.08 109.20
46 81.48 106.27
48 82.83 103.54
50 84.14 100.97
52 85.41 98.55
54 86.65 96.27
56 87.85 94.12
58 89.02 92.09
60 90.16 90.16
62 91.27 88.33
64 92.36 86.59
66 93.42 84.93
68 94.45 83.34
70 95.47 81.83
72 96.46 80.38
74 97.43 79.00
76 98.38 77.67
78 99.32 76.40
80 100.23 75.18
82 101.13 74.00
84 102.02 72.87
86 102.88 71.78
88 103.74 70.73
89 104.16 70.22
90 104.57 69.72
92 105.40 68.74
94 106.21 67.79
96 107.01 66.88
98 107.79 65.99
100 108.56 65.14






25
102 109.33 64.31
104 110.08 63.51
106 110.82 62.73
108 111.55 61.97
110 112.27 61.24
112 112.98 60.52
114 113.68 59.83
116 114.37 59.16
118 115.05 58.50
120 115.72 57.86


CLCULO DE LA CURVA I-D-TR PARA UN PERIODO DE RETORNO DE 25 AOS.
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
25
1440
= 81.08 (1/0.0185) ln(ln(25/(25-1))
P
25
1440
= 81.08 (54.05) (-3.20)
P
25
1440
= 81.08 +172.88
P
25
1440
= 253.96

P
25
60
= (R) (P
25
1440
)
P
25
60
= (0.2832) (253.96)
P
25
60
= 71.92

LUEGO APLICANDO LA FRMULA P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60
PODEMOS CLCULAR
LA PRECIPITACIN PARA CIERTA DURACIN; EN ESTE CASO CALCULAREMOS PRECIPITACIONES
PARA CADA 2 MIN, LO CUAL NOS GENERA LA SIGUIENTE TABLA:
CLCULO CURVA I-D-TR
PERIODO DE RETORNO EN AOS 25
PRECIPITACIN EN 60 MIN 71.92
DURACIN (MIN) PRECIPITACIN INTENSIDAD
2 19.29 578.72
4 35.78 536.65
6 46.83 468.31
8 55.38 415.37
10 62.45 374.71
12 68.53 342.64
14 73.89 316.65
16 78.70 295.11
18 83.08 276.92






26
20 87.10 261.31
22 90.84 247.75
24 94.33 235.83
26 97.61 225.25
28 100.70 215.79
30 103.63 207.27
32 106.42 199.54
34 109.08 192.50
36 111.63 186.05
38 114.07 180.12
40 116.42 174.63
42 118.68 169.55
44 120.86 164.82
46 122.97 160.40
48 125.01 156.27
50 126.99 152.39
52 128.91 148.75
54 130.78 145.31
56 132.59 142.06
58 134.36 138.99
60 136.08 136.08
62 137.76 133.31
64 139.40 130.68
66 141.00 128.18
68 142.56 125.79
70 144.09 123.51
72 145.59 121.32
74 147.06 119.23
76 148.49 117.23
78 149.90 115.31
80 151.29 113.46
82 152.64 111.69
84 153.97 109.98
86 155.28 108.34
88 156.57 106.75
89 157.20 105.98
90 157.83 105.22
92 159.08 103.75
94 160.30 102.32






27










CLCULO DE LA CURVA I-D-TR PARA UN PERIODO DE RETORNO DE 50 AOS.
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
50
1440
= 81.08 (1/0.0185) ln(ln(50/(50-1))
P
50
1440
= 81.08 (54.05) (-3.90)
P
50
1440
= 81.08 +210.90
P
50
1440
= 291.98

P
50
60
= (R) (P
50
1440
)
P
50
60
= (0.2832) (291.98)
P
50
60
= 82.69

LUEGO APLICANDO LA FRMULA P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60
PODEMOS
CLCULAR LA PRECIPITACIN PARA CIERTA DURACIN; EN ESTE CASO CALCULAREMOS
PRECIPITACIONES PARA CADA 2 MIN, LO CUAL NOS GENERA LA SIGUIENTE TABLA:

CLCULO CURVA I-D-TR
PERIODO DE RETORNO EN AOS 50
PRECIPITACIN EN 60 MIN 82.69
DURACIN (MIN) PRECIPITACIN INTENSIDAD
2 25.03 750.94
4 46.42 696.36
6 60.77 607.68
8 71.86 538.98
10 81.04 486.22
12 88.92 444.61
14 95.87 410.89
16 102.12 382.94
96 161.50 100.94
98 162.69 99.61
100 163.86 98.31
102 165.01 97.06
104 166.14 95.85
106 167.26 94.67
108 168.36 93.53
110 169.44 92.42
112 170.52 91.35
114 171.57 90.30
116 172.62 89.28
118 173.65 88.29
120 174.66 87.33






28
18 107.80 359.33
20 113.03 339.08
22 117.87 321.48
24 122.40 306.01
26 126.66 292.28
28 130.67 280.01
30 134.48 268.95
32 138.09 258.93
34 141.55 249.79
36 144.85 241.42
38 148.02 233.72
40 151.07 226.60
42 154.00 220.00
44 156.83 213.86
46 159.57 208.13
48 162.22 202.77
50 164.79 197.74
52 167.28 193.01
54 169.70 188.55
56 172.05 184.34
58 174.34 180.35
60 176.58 176.58
62 178.75 172.99
64 180.88 169.57
66 182.96 166.32
68 184.99 163.22
70 186.97 160.26
72 188.92 157.43
74 190.82 154.72
76 192.68 152.12
78 194.51 149.63
80 196.31 147.23
82 198.07 144.93
84 199.80 142.71
86 201.50 140.58
88 203.16 138.52
89 203.99 137.52
90 204.80 136.54
92 206.42 134.62






29
94 208.01 132.77
96 209.57 130.98
98 211.11 129.25
100 212.62 127.57
102 214.11 125.95
104 215.58 124.37
106 217.03 122.85
108 218.46 121.37
110 219.87 119.93
112 221.26 118.53
114 222.63 117.17
116 223.99 115.85
118 225.32 114.57
120 226.64 113.32


CLCULO DE LA CURVA I-D-TR PARA UN PERIODO DE RETORNO DE 100 AOS.
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
100
1440
= 81.08 (1/0.00896) ln(ln(100/(100-1))
P
100
1440
= 81.08 (54.05) (-4.60)
P
100
1440
= 81.08 +248.64
P
100
1440
= 329.72

P
100
60
= (R) (P
100
1440
)
P
100
60
= (0.2832) (329.72)
P
100
60
= 93.38

LUEGO APLICANDO LA FRMULA P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60
PODEMOS CLCULAR
LA PRECIPITACIN PARA CIERTA DURACIN; EN ESTE CASO CALCULAREMOS PRECIPITACIONES
PARA CADA 2 MIN, LO CUAL NOS GENERA LA SIGUIENTE TABLA:

CLCULO CURVA I-D-TR
PERIODO DE RETORNO EN AOS 100
PRECIPITACIN EN 60 MIN 93.38
DURACIN (MIN) PRECIPITACIN INTENSIDAD
2 31.49 944.64
4 58.40 875.98
6 76.44 764.43
8 90.40 678.01
10 101.94 611.64






30
12 111.86 559.29
14 120.60 516.88
16 128.46 481.72
18 135.61 452.02
20 142.18 426.54
22 148.28 404.40
24 153.98 384.94
26 159.33 367.68
28 164.38 352.24
30 169.16 338.33
32 173.72 325.72
34 178.06 314.22
36 182.22 303.69
38 186.20 294.01
40 190.04 285.05
42 193.73 276.75
44 197.29 269.03
46 200.73 261.82
48 204.06 255.08
50 207.29 248.75
52 210.43 242.80
54 213.47 237.19
56 216.43 231.89
58 219.31 226.88
60 222.12 222.12
62 224.86 217.61
64 227.54 213.32
66 230.15 209.23
68 232.70 205.33
70 235.20 201.60
72 237.65 198.04
74 240.04 194.63
76 242.39 191.36
78 244.69 188.22
80 246.94 185.21
82 249.16 182.31
84 251.33 179.52
86 253.47 176.84
88 255.57 174.25






31
89 256.61 172.99
90 257.63 171.76
92 259.66 169.35
94 261.66 167.02
96 263.63 164.77
98 265.56 162.59
100 267.47 160.48
102 269.34 158.44
104 271.19 156.46
106 273.02 154.54
108 274.81 152.67
110 276.59 150.86
112 278.33 149.11
114 280.06 147.40
116 281.76 145.74
118 283.44 144.12
120 285.10 142.55


CLCULO DE LA CURVA I-D-TR PARA UN PERIODO DE RETORNO DE 500 AOS.
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
500
1440
= 81.08 (1/0.0185) ln(ln(500/(500-1))
P
500
1440
= 81.08 (54.05) (-6.214)
P
500
1440
= 81.08 + 335.85
P
500
1440
= 416.93

P
500
60
= (R) (P
500
1440
)
P
500
60
= (0.2832) (416.93)
P
500
60
= 118.07

LUEGO APLICANDO LA FRMULA P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60
PODEMOS
CLCULAR LA PRECIPITACIN PARA CIERTA DURACIN; EN ESTE CASO CALCULAREMOS
PRECIPITACIONES PARA CADA 2 MIN, LO CUAL NOS GENERA LA SIGUIENTE TABLA:

CLCULO CURVA I-D-TR
PERIODO DE RETORNO EN AOS 500
PRECIPITACIN EN 60 MIN 118.07
DURACIN (MIN) PRECIPITACIN INTENSIDAD
2 49.27 1478.08
4 91.38 1370.65
6 119.61 1196.10






32
8 141.45 1060.88
10 159.51 957.04
12 175.03 875.13
14 188.71 808.76
16 201.00 753.74
18 212.18 707.28
20 222.47 667.41
22 232.01 632.76
24 240.93 602.32
26 249.30 575.30
28 257.20 551.14
30 264.69 529.38
32 271.81 509.65
34 278.61 491.67
36 285.11 475.19
38 291.35 460.03
40 297.35 446.02
42 303.12 433.03
44 308.70 420.95
46 314.08 409.67
48 319.30 399.12
50 324.35 389.22
52 329.25 379.91
54 334.02 371.13
56 338.65 362.84
58 343.16 354.99
60 347.56 347.56
62 351.84 340.49
64 356.03 333.78
66 360.11 327.38
68 364.11 321.27
70 368.02 315.44
72 371.84 309.87
74 375.59 304.53
76 379.26 299.42
78 382.86 294.51
80 386.39 289.80
82 389.86 285.26
84 393.26 280.90






33
86 396.60 276.70
88 399.89 272.65
89 401.51 270.68
90 403.12 268.75
92 406.29 264.97
94 409.42 261.33
96 412.49 257.81
98 415.52 254.40
100 418.50 251.10
102 421.44 247.91
104 424.33 244.81
106 427.19 241.80
108 430.00 238.89
110 432.77 236.06
112 435.51 233.31
114 438.21 230.64
116 440.87 228.04
118 443.50 225.51
120 446.10 223.05


CLCULO DE LA CURVA I-D-TR PARA UN PERIODO DE RETORNO DE 1000 AOS.
P
TR
1440
= (1/) ln(ln(TR/(TR-1))
P
1000
1440
= 81.08 (1/0.0185) ln(ln(1000/(1000-1))
P
1000
1440
= 81.08 (54.05) (-6.91)
P
1000
1440
= 81.08 +373.34
P
1000
1440
= 454.42

P
1000
60
= (R) (P
1000
1440
)
P
1000
60
= (0.2832) (454.42)
P
1000
60
= 128.69

LUEGO APLICANDO LA FRMULA P
TR
t
= (0.35ln(TR)+0.76)(0.54t
1/4
0.5) P
TR
60
PODEMOS
CLCULAR LA PRECIPITACIN PARA CIERTA DURACIN; EN ESTE CASO CALCULAREMOS
PRECIPITACIONES PARA CADA 2 MIN, LO CUAL NOS GENERA LA SIGUIENTE TABLA:

CLCULO CURVA I-D-TR
PERIODO DE RETORNO EN AOS 1000
PRECIPITACIN EN 60 MIN 128.69
DURACIN (MIN) PRECIPITACIN INTENSIDAD
2 58.14 1744.19






34
4 107.83 1617.41
6 141.14 1411.44
8 166.92 1251.87
10 188.22 1129.34
12 206.54 1032.68
14 222.68 954.36
16 237.19 889.44
18 250.38 834.61
20 262.52 787.57
22 273.78 746.68
24 284.30 710.75
26 294.18 678.88
28 303.51 650.37
30 312.34 624.69
32 320.75 601.41
34 328.77 580.18
36 336.44 560.74
38 343.81 542.85
40 350.88 526.32
42 357.70 511.00
44 364.27 496.74
46 370.63 483.43
48 376.78 470.98
50 382.74 459.29
52 388.53 448.30
54 394.15 437.95
56 399.62 428.16
58 404.94 418.90
60 410.13 410.13
62 415.19 401.79
64 420.12 393.87
66 424.95 386.32
68 429.66 379.11
70 434.28 372.24
72 438.79 365.66
74 443.21 359.36
76 447.54 353.32
78 451.79 347.53
80 455.96 341.97






35
82 460.05 336.62
84 464.06 331.47
86 468.01 326.52
88 471.88 321.74
89 473.80 319.41
90 475.69 317.13
92 479.44 312.68
94 483.13 308.38
96 486.76 304.22
98 490.33 300.20
100 493.85 296.31
102 497.31 292.54
104 500.73 288.88
106 504.10 285.34
108 507.41 281.90
110 510.69 278.56
112 513.92 275.31
114 517.10 272.16
116 520.25 269.09
118 523.35 266.11
120 526.41 263.21








36
DIBUJANDO LA GRFICA DE LAS DURACIONES CONTRA LAS INTENSIDADES EN ESCALA
LOGARTMICA DE CADA UNO DE LOS PERIODOS DE RETORNO SE TIENE LO SIGUIENTE:





DURACIN DEL INTERVALO d EN MINUTOS
I
N
T
E
R
V
A
L
O

D
E

P
R
E
C
I
P
I
T
A
C
I

N

E
N

m
m
/
h
r
CURVAS INTENSIDAD-DURACIN-PERIODO DE RETORNO
2 3 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90 100
50
60
70
80
90
100
200
300
400
500
600
700
800
900
1000
200
2000
3000
T
=

5

A

O
S
T
=
1
0

A

O
S
T
=
5
0

A

O
S
T
=
1
0
0

A

O
S
T
=
5
0
0

A

O
S
T
=
1
0
0
0

A

O
S
40
T
=
2
5

A

O
S






37
5.- DETERMINACIN DEL GASTO MXIMO PROBABLE PARA EL DISEO
DE LAS OBRAS DE DRENAJE

PARA CALCULAR AVENIDAS MXIMAS EXISTEN VARIOS MTODOS, QUE SE CLASIFICAN
DE LA SIGUIENTE MANERA: EMPRICOS, SEMIEMPRICOS, ESTADSTICOS E HIDRO-
METEOROLGICOS.

MTODOS EMPRICOS.
LOS MTODOS EMPRICOS SE EMPLEAN PARA TENER UNA IDEA PRELIMINAR SOBRE EL
GASTO DE DISEO O BIEN CUNADO NO SE CONOCEN LAS CARACTERSTICAS DE LA
PRECIPITACIN EN LA ZONA CORRESPONDIENTE DE LA CUENCA EN ESTUDIO, YA QUE
EN ELLOS INTERVIENEN COMO VARIABLES NICAMENTE LAS CARACTERSTICAS DE LA
CUENCA, LOS MTODOS EMPRICOS MS COMUNES SON: EL MTODO DE CREAGER Y EL
DE LOWRY QUE PROPORCIONAN EL GASTO DE DISEO EN FUNCIN DEL REA DE LA
CUENCA Y DE UN COEFICIENTE QUE DEPENDE DE LA REGIN HIDROLGICA
CORRESPONDIENTE.



MTODOS SEMIEMPRICOS.
LOS MTODOS SEMIEMPRICOS SON SIMILARES A LOS EMPRICOS, PERO HACEN
INTERVENIR ADEMS LA INTENSIDAD DE LLUVIA EN LA RELACIN FUNCIONAL QUE
DEFINE EL GASTO DE DISEO. ESTOS MTODOS SE BASAN EN EL CONOCIMIENTO DEL
CICLO HIDROLGICO Y DIFIEREN UNOS DE OTROS EN EL MAYOR O MENOR DETALLE
CON QUE TOMAN LOS FACTORES QUE INTERVIENEN EN DICHO CICLO.



MTODOS ESTADSTICOS.
SON DE GRAN UTILIDAD EN SITIOS EN LOS QUE SE CUENTA CON UN BUEN REGISTRO DE
LOS GASTOS OCURRIDOS. SE BASA EN SUPONER QUE LOS GASTOS MXIMOS ANUALES
AFORADOS EN UNA CUENCA, SON UNA MUESTRA ALEATORIA DE UNA POBLACIN DE
GASTOS MXIMOS.



MTODOS HIDROMETEOROLGICOS.
SE BASAN EN LA DETERMINACIN DE LA PRECIPITACIN MXIMA PROBABLE, A PARTIR
DE MTODOS METEOROLGICOS, PARA DETERMINAR LA TORMENTA DE DISEO, Y
CONVERTIR DICHA TORMENTA EN EL HIDROGRAMA DE DISEO MEDIANTE UNA
RELACIN PRECIPITACIN ESCURRIMIENTO.









38
EN CUMPLIMIENTO DE LOS TRMINOS DE REFERENCIA, PARA EL CLCULO DEL GASTO
MXIMO PROBABLE DE ESTE ESTUDIO UTILIZAREMOS EL MTODO DE CREAGER, EL
MTODO RACIONAL, EL MTODO DE CHOW; CUMPLIENDO CON LOS TRMINOS DE
REFERENCIA, LOS CLCULOS DE LAS OBRAS DE DRENAJE SE REALIZARN PARA UN
PERIODO DE RETORNO DE 25 AOS.

ALCANTARILLAS
CLCULO DEL GASTO MXIMO PROBABLE POR EL MTODO DE CREAGER.

PARA DETERMINAR EL GASTO DE LA AVENIDA MXIMA PROBABLE POR ESTE MTODO,
SE UTILIZA LA SIGUIENTE FRMULA:

Q=1.303 * Cc * (0.386 *Ac)




DONDE:
Q= GASTO EN (m
3
/s)
Ac= REA DE LA CUENCA (Km
2
)
Cc= PARAMETRO QUE DEPENDE DE LA REGIN HIDROLGICA
= 0.936 /(Ac)
0.048


VALORES DEL COEFICIENTE DE CREEAGER
No. DE REGIN DESCRIPCIN Cc

1 BAJA CALIFORNIA NORTE 30
2 BAJA CALIFORNIA SUR 72
3 RO COLORADO 14
4 NORESTE
ZONA NORTE 35
ZONA SUR 64
5 SISTEMA LERMA - CHAPALA - SANTIAGO
LERMA -CHAPALA 16
SANTIAGO 19
6 PACFICO CENTRO 10
7 CUENCA RO BALSAS
ALTO BALSAS 18
BAJO BALSAS 32
8 PACFICO SUR 62
9 ZONA CONCHOS
RIO BRAVO 23
ZONA SALADO - SAN JUAN 91
10 GOLFO NORTE 61
11 CUENCA RO PNUCO






39








LA REGIN HIDROLGICA QUE CORRESPONDE AL REA EN ESTUDIO ES LA NMERO 6
(PACFICO CENTRO) A LA CUAL LE CORRESPONDE UN Cc = 10.
GASTO PARA LA MICROCUENCA 1:
= 0.936 /(Ac)
0.048

= 0.936 /(0.227)
0.048

= 0.936 /0.931
= 1.01
LUEGO:
Q=1.303 * Cc * (0.386 *Ac)


Q=1.303 * 10 * (0.386 *0.227)
1.01

Q=1.303 * 10 * 0.086
Q=1.11 m
3
/s
GASTO PARA LA MICROCUENCA 2:
= 0.936 /(Ac)
0.048

= 0.936 /(0.273)
0.048
= 0.936 /0.940
= 0.996
LUEGO:
Q=1.303 * Cc * (0.386 *Ac)


Q=1.303 * 10 * (0.386 *0.273)
0.996

Q=1.303 * 10 * 0.106
Q=1.39 m
3
/s

GASTO PARA LA MICROCUENCA 3:
= 0.936 /(Ac)
0.048

= 0.936 /(0.256)
0.048
= 0.936 /0.936
= 1.00
LUEGO:
Q=1.303 * Cc * (0.386 *Ac)


Q=1.303 * 10 * (0.386 *0.256)
1.00

Q=1.303 * 10 * 0.098
Q=1.28 m
3
/s

GASTO PARA LA MICROCUENCA 4:
= 0.936 /(Ac)
0.048

= 0.936 /(0.447)
0.048
= 0.936 /0.962
= 0.973
LUEGO:
Q=1.303 * Cc * (0.386 *Ac)


Q=1.303 * 10 * (0.386 *0.447)
0.973

Q=1.303 * 10 * 0.181
Q=2.36 m
3
/s
CLCULO DEL GASTO MXIMO PROBABLE POR EL MTODO RACIONAL.
ALTO PNUCO 14
BAJO PNUCO 67
12 GOLFO CENTRO 59
13 RO PAPALUAPAN 36
14 GOLFO SUR 36
15 SISTEMA GRIJALVA - USUMACINTA 50






40

PARA DETERMINAR EL GASTO DE LA AVENIDA MXIMA PROBABLE POR ESTE MTODO,
SE UTILIZA LA SIGUIENTE FRMULA:

Q= 0.278 * C
E
* I * Ac

DONDE:
Q= GASTO EN (m
3
/s)
Ac= REA DE LA MICROCUENCA (Km
2
)
C
E
= COEFICIENTE DE ESCURRIMIENTO
I = INTENSIDAD DE LLUVIA (mm)

PARA DETERMINAR EL COEFICIENTE DE ESCURRIMIENTO (C
E
) UTILIZAREMOS EL
MTODO DE LOS NMEROS DE ESCURRIMIENTO, EL CUAL DETERMINA EL COEFICIENTE
DE ESCURRIMIENTO EN FUNCIN DE LA PRECIPITACIN EFECTIVA Y LA PRECIPITACIN
TOTAL, LA FRMULA PARA DETERMINAR LA PRECIPITACIN EFECTIVA (Pe) ES LA
SIGUIENTE:

Pe = ((P-(508/N)+5.08)
2
) / (P+ (2032/N)-20.32)

DONDE:
Pe = PRECIPITACIN EFECTIVA O EN EXCESO
P = PRECIPITACIN TOTAL (PROMEDIO)
N = NEMRO DE ESCURRIMIENTO

EL VALOR DEL NMERO DE ESCURRIMIENTO DEPENDE DEL TIPO DE SUELO, LA
COBERTURA VEGETAL, LA PENDIENTE DEL TERRENO Y LA PRECIPITACIN
ANTECEDENTE, ENTRE OTROS FACTORES, SE DETERMINA POR MEDIO DE TABLAS QUE
ACONTINUACIN SE MUESTRAN:


USO DE LA TIERRA Y
COBERTURA
TRATAMIENTO
DEL SUELO
PENDIENTE DEL
TERRENO EN %
TIPO DE SUELO
A B C D
SIN CULTIVO SURCOS RECTOS - 77 86 91 94

CULTIVO EN SURCO SURCOS RECTOS > 1 72 81 88 91
SURCOS RECTOS < 1 67 78 85 89
CONTORNEO > 1 70 79 84 88
CONTORNEO < 1 65 75 82 86
TERRAZAS > 1 66 74 80 82
TERRAZAS < 1 62 71 78 81

CEREALES SURCOS RECTOS > 1 65 76 84 88
SURCOS RECTOS < 1 63 75 83 87
CONTORNEO > 1 63 74 82 85
CONTORNEO < 1 61 73 81 84
TERRAZAS > 1 61 72 79 82
TERRAZAS < 1 59 70 78 81






41

LEGUMINOSAS O
PRADERAS CON
ROTACIN
SURCOS RECTOS > 1 66 77 85 89
SURCOS RECTOS < 1 58 72 81 85
CONTORNEO > 1 64 75 83 85
CONTORNEO < 1 55 69 78 83
TERRAZAS > 1 63 73 80 83
TERRAZAS < 1 51 67 76 80

PASTIZALES - > 1 68 79 86 89
- < 1 39 61 74 80
CONTORNEO > 1 47 67 81 88
CONTORNEO < 1 6 35 70 79

PRADERA
PERMANENTE - < 1 30 58 71 78

BOSQUES NATURALES
MUY RALO - - 56 75 86 91
RALO - - 46 68 78 84
NORMAL - - 36 60 70 77
ESPESO - - 26 52 62 69
MUY ESPESO - - 15 44 54 61

CAMINOS
DE TERRRACERA - - 72 82 87 89
CON SUP. DURA - - 74 84 90 92


TIPO DE SUELO TEXTURA DEL SUELO
A ARENAS CON POCO LIMO Y ARCILLA; SUELOS
MUY PERMEABLES

B ARENAS FINAS Y LIMOS

C
ARENAS MUY FINAS, LIMOS, SUELOS CON ALTO
CONTENIDO DE ARCILLA



D ARCILLAS EN GRANDES CANTIDADES, SUELOS POCO
PROFUNDOS CON SUBHORIZONTES DE ROCA SANA;
SUELOS MUY IMPERMEABLES




DE ACUERDO CON LAS CARACTERSTICAS DEL SUELO DE LA CUENCA EN ESTUDIO, STA
SE CLASIFICA COMO UN SUELO TIPO B, DEL REA TOTAL DE LA CUENCA EL 70%






42
CORRESPONDE A BOSQUE NATURAL NORMAL (N= 60), EL 28% CORRESPONDE A
CULTIVOS EN SURCOS RECTOS CON PENDIENTE MENOR AL 1% (N=78), Y EL 2%
CORRESPONDE A CAMINOS DE TERRACERA (N=82); DE ACUERDO CON ESTAS
CARACTERSTICAS SE CALCULA EL VALOR DE N DE LA SIGUIENTE MANERA:

N = (0.70)X(60) + (0.28)X(78) + (0.02)X(82)
N = 42.00 + 21.84 + 1.64
N= 65.48

CON EL VALOR CALCULADO DE N Y RECORDANDO QUE LA PRECIPITACIN PROMEDIO
CALCULADA ES DE 110.83mm Y APLICANDO LA FRMULA PARA CALCULAR LA
PRECIPITACIN EFECTIVA Pe TENEMOS:

Pe = ((P-(508/N)+5.08)
2
) / (P+ (2032/N)-20.32)
Pe = ((11.08-(508/65.48)+5.08)
2
) / (11.08+ (2032/65.48)-20.32)
Pe = 70.59 / 21.79
Pe = 3.24 CM

SABIENDO QUE EL COEFICIENTE DE ESCURRIMIENTO ES IGUAL AL COCIENTE DEL
ESCURRIMIENTO DIRECTO ENTRE EL VOLUMEN LLOVIDO, QUE A SU VEZ DEPENDE DE LA
PRECIPITACIN EN EXCESO Y LA PRECIPITACIN TOTAL TENEMOS QUE:

Ce =( V
ed
/ V
ll
) = ((Pe)(Ac)) / ((P)(Ac))
Ce = Pe / P
Ce = 3.24 / 11.08
Ce = 0.392


PARA CALCULAR LA INTENSIDAD ES NECESARIO CONOCER LA DURACIN DE LA LLUVIA
PARA EL GASTO PICO, QUE ES IGUAL AL TIEMPO DE CONCENTRACIN, EL CUAL ES EL
TIEMPO QUE TRANSCURRE ENTRE EL INICIO DE LA LLUVIA Y EL ESTABLECIMIENTO DEL
GASTO DE EQUILIBRIO, STE SE CALCULA CON LA SIGUIENTE FRMULA:

Tc = (0.000375(Lcp)
0.77
) / (Scp)
0.385


DONDE:
Tc= TIEMPO DE CONCENTRACIN (EN HORAS)
Lcp= LONGITUD DEL CAUCE PRINCIPAL (EN METROS)
Scp= PENDIENTE DEL CAUCE PRINCIPAL (MTODO DE TAYLOR)

CALCULANDO TENEMOS:

MICROCUENCA 1
Tc = (0.000375(1105.74)
0.77
) / (0.163)
0.385

Tc = 0.0827/0.497
Tc = 0.166 HRS = 9.98 MIN.

MICROCUENCA 2
Tc = (0.000375(1691.39)
0.77
) / (0.261)
0.385

Tc = 0.1147/0.596
Tc = 0.193 HRS = 11.55 MIN.

MICROCUENCA 3






43
Tc = (0.000375(1334.82)
0.77
) / (0.228)
0.385

Tc = 0.0956/0.566
Tc = 0.169 HRS = 10.13 MIN

MICROCUENCA 4
Tc = (0.000375(1625.45)
0.77
) / (0.265)
0.385

Tc = 0.111/0.600
Tc = 0.185 HRS = 11.10 MIN


LUEGO INGRESAMOS EL VALOR DEL TIEMPO DE CONCENTRACIN (Tc), QUE ES IGUAL A
LA DURACIN, A LA GRFICA DE LAS CURVAS I-D-TR, UBICAMOS ESTE VALOR EN EL EJE
DE LAS ABSCISAS DE LA GRFICA, LOS VALORES DE LA INTENSIDAD PARA EL PERIODO
DE RETORNO DE 25 AOS SON LOS VALORES DE LA ORDENADA EN LA INTERSECCIN
DE LA CURVA; DE ACUARDO CON LA GRFICA QUE SE MUESTRA A CONTINUACIN LOS
VALORES DE LA INTENSIDAD DE LLUVIA CORRESPONDIENTES A LOS PERIODOS DE
RETORNO DE 25 AOS PARA CADA MICROCUENCA SON: MICROCUENCA 1 (374.71MM/HR),
MICROCUENCA 2 (342.64MM/HR), MICROCUENCA 3 (374.71MM/HR) Y MICROCUENCA 4
(357.78MM/HR).


































DURACIN DEL INTERVALO d EN MINUTOS
I
N
T
E
R
V
A
L
O

D
E

P
R
E
C
I
P
I
T
A
C
I

N

E
N

m
m
/
h
r
CURVAS INTENSIDAD-DURACIN-PERIODO DE RETORNO
2 3 4 5 6 7 8 9 10 20 30 40 50 60 70 80 90 100
50
60
70
80
90
100
200
300
400
500
600
700
800
900
1000
200
2000
3000
T
=

5

A

O
S
T
=
1
0

A

O
S
T
=
5
0

A

O
S
T
=
1
0
0

A

O
S
T
=
5
0
0

A

O
S
T
=
1
0
0
0

A

O
S
40
T
=
2
5

A

O
S






44

*CLCULO DEL GASTO ALCANTARILLA 1
DATOS:
Q= 0.278 * C
E
* I * Ac
Ac= 0.227 Km
2

C
E
= 0.392
I= 374.71 MM/HR

SUSTITUYENDO LOS DATOS EN LA ECUACIONES TENEMOS:
Q=0.278*0.392*374.71*0.227
Q=9.27 m
3
/s


*CLCULO DEL GASTO ALCANTARILLA 2
DATOS:
Q= 0.278 * C
E
* I * Ac
Ac= 0.273 Km
2

C
E
= 0.392
I= 342.64 MM/HR

SUSTITUYENDO LOS DATOS EN LA ECUACIONES TENEMOS:
Q=0.278*0.392*342.64*0.273
Q=10.19 m
3
/s

*CLCULO DEL GASTO ALCANTARILLA 4
DATOS:
Q= 0.278 * C
E
* I * Ac
Ac= 0.256 Km
2

C
E
= 0.392
I= 374.71 MM/HR

SUSTITUYENDO LOS DATOS EN LA ECUACIONES TENEMOS:
Q=0.278*0.392*374.71*0.256
Q=10.45 m
3
/s

*CLCULO DEL GASTO ALCANTARILLA 5
DATOS:
Q= 0.278 * C
E
* I * Ac
Ac= 0.447 Km
2

C
E
= 0.392
I= 357.78 MM/HR

SUSTITUYENDO LOS DATOS EN LA ECUACIONES TENEMOS:
Q=0.278*0.392*357.78*0.447
Q=17.43 m
3
/s

CLCULO DE LA AVENDA MXIMA PROBABLE (AMP) POR EL MTODO DE CHOW







45
ESTE MTODO ES UNO DE LOS LLAMADOS HIDROGRAMAS UNITARIOS SINTTICOS Y SE
UTILIZAN EN CUENCAS DONDE NO SE CUENTA CON UNA ESTACIN HIDROMTRICA O
REGISTROS PLUVIOGRFICOS NECESARIOS; CON ESTE MTODO PUEDEN OBTENERSE
HIDROGRAMAS UNITARIOS USANDO NICAMENTE DATOS DE CARACTERSTICAS
GENERALES DE LA CUENCA.
STE MTODO SOLO PROPORCIONA EL GASTO DE PICO Y ES APLICABLE A CUENCAS NO
URBANAS CON REA MENOR A 25 KM
2
; LA FRMULA PARA DETERMINAR EL GASTO DE
PICO POR STE MTODO ES:

Qp = ((0.278 X Pe XAc)/ d
e
) X (Z)

EN ESTE CASO EL PROCEDIMIENTO APLICABLE PARA EVALUAR Pe ES EL DE LOS
NMEROS DE ESCURRIMIENTO (APLICADO EN EL MTODO RACIONAL); EL FACTOR DE
REDUCCIN DE PICO Z SE CALCULA, CON UNA FUNCIN DEL TIEMPO DE RETRASO t
r
(EL
CUAL ES EL TIEMPO QUE TRANSCURRE DEL CENTRO DE MASA DE LA PRECIPITACIN AL
PICO DEL HIDROGRAMA) Y LA DURACIN EN EXCESO de.

EL VALOR DE Z SE DETERMINA POR MEDIO DE LA GRFICA 8.20 INCLUIDA EN LOS
ANEXOS DE ESTE ESTUDIO.
PARA CALCULAR EL TIEMPO DE RETRASO SE APLICA LA SIGUIENTE FRMULA:

t
r
= 0.005 (L/(S)
1/2
)
0.64

DONDE:
t
r
= PERIODO DE RETRASO EN HORAS
L = LONGITUD DEL CAUCE PRINCIPAL EN METROS
S = PENDIENTE DEL CAUCE PRINCIPAL EN %

APLICANDO LA FRMULA Y SUSTITUYENDO VALORES TENEMOS
t
r
= 0.005 (11 690/(6.20)
1/2
)
0.64

t
r
= 0.005 (4694.82)
0.64

t
r
= 0.005 (223.79)
t
r
= 1.12 HR = 67.20 MIN.


PARA DETERMINAR LAS INTENSIDADES DE LAS DURACIONES PROPUESTAS EN LAS
TABLAS, NOS APOYAMOS EN LAS CURVAS I-D-TR, OBVIAMENTE SE SELECCIONA LA
CURVA DEL PERIODO DE RETORNO DEL CUAL SE QUIERE CALCULAR EL GASTO PICO EN
ESTE CASO 25 AOS; N=65.48 ES EL VALOR CALCULADO PARA EL MTODO RACIONAL.












46
*CLCULO DEL GASTO ALCANTARILLA 1

ALCANTARILLA 1
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 65.48 L= 1105.74 S= 16.00 Ac = 0.227

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 48.83 10.96 0.913 0.620 11.46
20 261.31 87.10 72.87 10.96 1.825 0.910 12.55
30 207.27 103.64 89.13 10.96 2.738 1.000 11.25
40 174.63 116.42 101.76 10.96 3.650 1.000 9.63
50 152.39 126.99 112.23 10.96 4.563 1.000 8.50
60 136.08 136.08 121.23 10.96 5.475 1.000 7.65
70 123.51 144.10 129.18 10.96 6.388 1.000 6.99
80 113.46 151.28 136.32 10.96 7.300 1.000 6.45
90 105.22 157.83 142.83 10.96 8.213 1.000 6.01
100 98.31 163.85 148.81 10.96 9.126 1.000 5.63




*CLCULO DEL GASTO ALCANTARILLA 2

ALCANTARILLA 2
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 65.48 L= 1691.39 S= 26.10 Ac = 0.273

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 48.83 12.30 0.813 0.570 12.68
20 261.31 87.10 72.87 12.30 1.626 0.880 14.60
30 207.27 103.64 89.13 12.30 2.439 1.000 13.53
40 174.63 116.42 101.76 12.30 3.252 1.000 11.58
50 152.39 126.99 112.23 12.30 4.065 1.000 10.22
60 136.08 136.08 121.23 12.30 4.878 1.000 9.20
70 123.51 144.10 129.18 12.30 5.691 1.000 8.40
80 113.46 151.28 136.32 12.30 6.505 1.000 7.76
90 105.22 157.83 142.83 12.30 7.318 1.000 7.23
100 98.31 163.85 148.81 12.30 8.131 1.000 6.78









47

*CLCULO DEL GASTO ALCANTARILLA 4

ALCANTARILLA 4
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 65.48 L= 1334.82 S= 22.80 Ac = 0.259

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 48.83 11.04 0.906 0.610 12.87
20 261.31 87.10 72.87 11.04 1.812 0.900 14.17
30 207.27 103.64 89.13 11.04 2.718 1.000 12.84
40 174.63 116.42 101.76 11.04 3.624 1.000 10.99
50 152.39 126.99 112.23 11.04 4.530 1.000 9.70
60 136.08 136.08 121.23 11.04 5.436 1.000 8.73
70 123.51 144.10 129.18 11.04 6.342 1.000 7.97
80 113.46 151.28 136.32 11.04 7.248 1.000 7.36
90 105.22 157.83 142.83 11.04 8.154 1.000 6.86
100 98.31 163.85 148.81 11.04 9.060 1.000 6.43





*CLCULO DEL GASTO ALCANTARILLA 5

ALCANTARILLA 5
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 65.48 L= 1625.45 S= 26.50 Ac = 0.447

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 48.83 11.93 0.838 0.580 21.12
20 261.31 87.10 72.87 11.93 1.676 0.890 24.18
30 207.27 103.64 89.13 11.93 2.514 1.000 22.15
40 174.63 116.42 101.76 11.93 3.352 1.000 18.97
50 152.39 126.99 112.23 11.93 4.190 1.000 16.73
60 136.08 136.08 121.23 11.93 5.029 1.000 15.07
70 123.51 144.10 129.18 11.93 5.867 1.000 13.76
80 113.46 151.28 136.32 11.93 6.705 1.000 12.70
90 105.22 157.83 142.83 11.93 7.543 1.000 11.83
100 98.31 163.85 148.81 12.30 8.131 1.000 11.10







48
PARA EL DISEO DE LAS ALCANTARILLAS SE TOMARN LOS VALORES DE LOS GASTOS
OBTENIDOS POR EL MTODO DE VEN TE CHOW YA QUE SON LOS VALORES MS
CRTICOS.

CLCULO HIDRULICO DE LAS ALCANTARILLAS

PARA SECCIN DE MXIMA EFICIENCIA SE UTILIZAR LA SIGUIENTE FRMULA GENERAL
d=((0.79*Q*n) / (S
1/2
))
3/8


SUGIRIENDO LA LONGITUD DE LA BASE EL DOBLE DEL TIRANTE TENDREMOS b=2d;
A
H
=2d
2
; P
m
=4d Y R
H
=d/2; UNA VEZ CALCULADO EL TIRANTE SE CALCULA LA VELOCIDAD
CON LA FRMULA DE MANNING Y LUEGO DESPEJANDO EL REA DE LA FRMULA DE LA
CONTINUIDAD OBTENDREMOS EL REA HIDRULICA REQUERIDA PARA DESALOJAR EL
GASTO DE DISEO, DESPUES SE PROPONE LA SECCIN DE LA ALCANTARILLA.

ALCANTARILLA 1
DATOS:
Q=12.55 M
3
/S
n=0.06
S=0.163

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
d=((0.79*Q*n) / (S
1/2
))
3/8

d=((0.79*12.55*0.06) / (0.16
1/2
))
3/8

d=((0.595)/ (0.40))
3/8

d=1.16 m

V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.06)* (1.16 / 2)
2/3
* (0.16)
1/2

V= (16.67)* (0.70) * (0.40)
V=4.67 m/s

Q=A*V
A=Q / V
A=12.55 / 4.67
A=2.69 m
2


SE PROPONE LA SECCIN DE LA ALCANTARILLA 1 b=2.50 m; h=1.50 m










49
ALCANTARILLA 2
DATOS:
Q=14.60 M
3
/S
n=0.06
S=0.261

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
d=((0.79*Q*n) / (S
1/2
))
3/8

d=((0.79*14.6*0.06) / (0.261
1/2
))
3/8

d=((0.69)/ (0.51))
3/8

d=1.12 m

V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.06)* (1.12 / 2)
2/3
* (0.261)
1/2

V= (16.67)* (0.68) * (0.51)
V=5.78 m/s

Q=A*V
A=Q / V
A=14.60 / 5.78
A=2.53 m
2


SE PROPONE LA SECCIN DE LA ALCANTARILLA 2 b=2.50 m; h=1.50 m

ALCANTARILLA 4
DATOS:
Q=14.17 M
3
/S
n=0.06
S=0.228

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
d=((0.79*Q*n) / (S
1/2
))
3/8

d=((0.79*14.17*0.06) / (0.228
1/2
))
3/8

d=((0.59)/ (0.48))
3/8

d=1.13 m

V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.06)* (1.13 / 2)
2/3
* (0.228)
1/2

V= (16.67)* (0.69) * (0.48)
V=5.48 m/s

Q=A*V
A=Q / V
A=14.17 / 5.48
A=2.58 m
2


SE PROPONE LA SECCIN DE LA ALCANTARILLA 4 b=2.50 m; h=1.50 m








50
ALCANTARILLA 5
DATOS:
Q=24.18 M
3
/S
n=0.06
S=0.265

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
d=((0.79*Q*n) / (S
1/2
))
3/8

d=((0.79*24.18*0.06) / (0.265
1/2
))
3/8

d=((1.15)/ (0.51))
3/8

d=1.36 m

V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.06)* (1.36 / 2)
2/3
* (0.265)
1/2

V= (16.67)* (0.77) * (0.51)
V=6.61 m/s

Q=A*V
A=Q / V
A=24.18 / 6.61
A=3.65 m
2


SE PROPONE LA SECCIN DE LA ALCANTARILLA 5 b=3.00 m; h=1.50 m

CUNETAS
SE HAR EL DISEO DE LAS CUNETAS CON LOS VALORES DE LOS GASTOS ARROJADOS
POR EL MTODO DE VEN TE CHOW; PARA ESTA OBRA DE DRENAJE SE ADOPTAR LA
SECCIN MS CRTICA DE ACUERDO A LOS DATOS Y LOS CLCULOS REALIZADOS, LOS
CUALES SON LOS SIGUIENTES:
*CLCULO DEL GASTO CUNETA 1
CUNETA 1
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 84 L= 200 S= 1.80 Ac = 0.0011

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 57.00 7.38 1.355 0.810 0.08
20 261.31 87.10 81.55 7.38 2.710 1.000 0.07
30 207.27 103.64 98.05 7.38 4.065 1.000 0.06
40 174.63 116.42 110.81 7.38 5.420 1.000 0.05
50 152.39 126.99 121.36 7.38 6.774 1.000 0.04
60 136.08 136.08 130.44 7.38 8.129 1.000 0.04
70 123.51 144.10 138.45 7.38 9.484 1.000 0.04
80 113.46 151.28 145.63 7.38 10.839 1.000 0.03
90 105.22 157.83 152.17 7.38 12.194 1.000 0.03
100 98.31 163.85 158.18 7.38 13.549 1.000 0.03






51

*CLCULO DEL GASTO CUNETA 2
CUNETA 2
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 84 L= 280 S= 1.60 Ac = 0.0024

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 57.00 9.51 1.052 0.690 0.16
20 261.31 87.10 81.55 9.51 2.104 1.000 0.16
30 207.27 103.64 98.05 9.51 3.156 1.000 0.13
40 174.63 116.42 110.81 9.51 4.208 1.000 0.11
50 152.39 126.99 121.36 9.51 5.260 1.000 0.10
60 136.08 136.08 130.44 9.51 6.312 1.000 0.09
70 123.51 144.10 138.45 9.51 7.364 1.000 0.08
80 113.46 151.28 145.63 9.51 8.416 1.000 0.07
90 105.22 157.83 152.17 9.51 9.468 1.000 0.07
100 98.31 163.85 158.18 9.51 10.520 1.000 0.06

*CLCULO DEL GASTO CUNETA 3
CUNETA 3
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 84 L= 20 S= 2.20 Ac = 0.00028

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 57.00 1.59 6.307 1.000 0.03
20 261.31 87.10 81.55 1.59 12.613 1.000 0.02
30 207.27 103.64 98.05 1.59 18.920 1.000 0.01
40 174.63 116.42 110.81 1.59 25.226 1.000 0.01
50 152.39 126.99 121.36 1.59 31.533 1.000 0.01
60 136.08 136.08 130.44 1.59 37.840 1.000 0.01
70 123.51 144.10 138.45 1.59 44.146 1.000 0.01
80 113.46 151.28 145.63 1.59 50.453 1.000 0.01
90 105.22 157.83 152.17 1.59 56.759 1.000 0.01
100 98.31 163.85 158.18 1.59 63.066 1.000 0.01









52
*CLCULO DEL GASTO CUNETA 4
CUNETA 4
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 84 L= 246 S= 3.00 Ac = 0.0023

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 57.00 7.16 1.398 0.820 0.18
20 261.31 87.10 81.55 7.16 2.795 1.000 0.16
30 207.27 103.64 98.05 7.16 4.193 1.000 0.13
40 174.63 116.42 110.81 7.16 5.590 1.000 0.11
50 152.39 126.99 121.36 7.16 6.988 1.000 0.09
60 136.08 136.08 130.44 7.16 8.385 1.000 0.08
70 123.51 144.10 138.45 7.16 9.783 1.000 0.08
80 113.46 151.28 145.63 7.16 11.180 1.000 0.07
90 105.22 157.83 152.17 7.16 12.578 1.000 0.06
100 98.31 163.85 158.18 7.16 13.975 1.000 0.06


*CLCULO DEL GASTO CUNETA 5
CUNETA 5
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 84 L= 462 S= 4.00 Ac = 0.0028

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 57.00 9.77 1.024 0.680 0.18
20 261.31 87.10 81.55 9.77 2.047 1.000 0.19
30 207.27 103.64 98.05 9.77 3.071 1.000 0.15
40 174.63 116.42 110.81 9.77 4.095 1.000 0.13
50 152.39 126.99 121.36 9.77 5.118 1.000 0.11
60 136.08 136.08 130.44 9.77 6.142 1.000 0.10
70 123.51 144.10 138.45 9.77 7.166 1.000 0.09
80 113.46 151.28 145.63 9.77 8.189 1.000 0.09
90 105.22 157.83 152.17 9.77 9.213 1.000 0.08
100 98.31 163.85 158.18 9.77 10.237 1.000 0.07









53
*CLCULO DEL GASTO CUNETA 6
CUNETA 6
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 84 L= 30 S= 4.00 Ac = 0.00033

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 57.00 1.70 5.891 1.000 0.03
20 261.31 87.10 81.55 1.70 11.782 1.000 0.02
30 207.27 103.64 98.05 1.70 17.673 1.000 0.02
40 174.63 116.42 110.81 1.70 23.564 1.000 0.02
50 152.39 126.99 121.36 1.70 29.454 1.000 0.01
60 136.08 136.08 130.44 1.70 35.345 1.000 0.01
70 123.51 144.10 138.45 1.70 41.236 1.000 0.01
80 113.46 151.28 145.63 1.70 47.127 1.000 0.01
90 105.22 157.83 152.17 1.70 53.018 1.000 0.01
100 98.31 163.85 158.18 1.70 58.909 1.000 0.01


*CLCULO DEL GASTO CUNETA 7
CUNETA 7
CLCULO DEL GASTO PICO PARA UN PERIODO DE RETORNO DE 25 AOS
60 N= 84 L= 80 S= 6.60 Ac = 0.00076

d
e
(MIN) INTEN. mm/hr P mm Pe mm t
r
(MIN) d
e
/ t
r
Z Q
p
m
3
/s
10 374.71 62.45 57.00 2.71 3.691 1.000 0.07
20 261.31 87.10 81.55 2.71 7.382 1.000 0.05
30 207.27 103.64 98.05 2.71 11.073 1.000 0.04
40 174.63 116.42 110.81 2.71 14.764 1.000 0.04
50 152.39 126.99 121.36 2.71 18.455 1.000 0.03
60 136.08 136.08 130.44 2.71 22.147 1.000 0.03
70 123.51 144.10 138.45 2.71 25.838 1.000 0.03
80 113.46 151.28 145.63 2.71 29.529 1.000 0.02
90 105.22 157.83 152.17 2.71 33.220 1.000 0.02
100 98.31 163.85 158.18 2.71 36.911 1.000 0.02









54
DETALLE DE CUNETA TIPO



REVISIN DE CUNETA 1
DATOS:
Q=0.07 M
3
/S
n=0.014
S=0.018
A=0.135
P=2.00

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.014)* (0.135 / 2.00)
2/3
* (0.018)
1/2

V= (71.43)* (0.166) * (0.134)
V=1.59 m/s

Q=A*V
A=Q / V
A=0.07 / 1.59
A=0.044 m
2
; SI CUMPLE.



REVISIN DE CUNETA 2
DATOS:
Q=0.16 M
3
/S
SIN ESCALA
' `'
CARPETA
BL=0.10 m
d=0.30 m
P =2.00m
M
1.20
0.80 0.40
A =0.135 m
H
2






55
n=0.014
S=0.016
A=0.135
P=2.00

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.014)* (0.135 / 2.00)
2/3
* (0.016)
1/2

V= (71.43)* (0.166) * (0.126)
V=1.50 m/s

Q=A*V
A=Q / V
A=0.16 / 1.50
A=0.107 m
2
; SI CUMPLE.


REVISIN DE CUNETA 3
DATOS:
Q=0.03 M
3
/S
n=0.014
S=0.022
A=0.135
P=2.00

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.014)* (0.135 / 2.00)
2/3
* (0.022)
1/2

V= (71.43)* (0.166) * (0.148)
V=1.76 m/s

Q=A*V
A=Q / V
A=0.03 / 1.76
A=0.017 m
2
; SI CUMPLE.



REVISIN DE CUNETA 4
DATOS:
Q=0.18 M
3
/S
n=0.014
S=0.030
A=0.135
P=2.00

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.014)* (0.135 / 2.00)
2/3
* (0.030)
1/2

V= (71.43)* (0.166) * (0.173)
V=2.05 m/s

Q=A*V






56
A=Q / V
A=0.18 / 2.05
A=0.088 m
2
; SI CUMPLE.

REVISIN DE CUNETA 5
DATOS:
Q=0.19 M
3
/S
n=0.014
S=0.040
A=0.135
P=2.00

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.014)* (0.135 / 2.00)
2/3
* (0.040)
1/2

V= (71.43)* (0.166) * (0.20)
V=2.37 m/s

Q=A*V
A=Q / V
A=0.19 / 2.37
A=0.080 m
2
; SI CUMPLE

REVISIN DE CUNETA 6
DATOS:
Q=0.03 M
3
/S
n=0.014
S=0.040
A=0.135
P=2.00

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.014)* (0.135 / 2.00)
2/3
* (0.040)
1/2

V= (71.43)* (0.166) * (0.20)
V=2.37 m/s

Q=A*V
A=Q / V
A=0.03 / 2.37
A=0.013 m
2
; SI CUMPLE

REVISIN DE CUNETA 7
DATOS:
Q=0.07 M
3
/S
n=0.014
S=0.066
A=0.135
P=2.00

APLICANDO FRMULAS Y SUSTITUYENDO VALORES TENEMOS:
V= (1/n)* (R
H
)
2/3
* (S)
1/2

V= (1/0.014)* (0.135 / 2.00)
2/3
* (0.066)
1/2







57
V= (71.43)* (0.166) * (0.26)
V=3.05 m/s

Q=A*V
A=Q / V
A=0.07 / 3.05
A=0.023 m
2
; SI CUMPLE


EN TODOS LOS CASOS CUMPLE LA SECCIN PROPUESTA POR LO TANTO SE ACEPTA
LA SECCIN TIPO.

You might also like