You are on page 1of 1

A'

10
A
B
C
D
E
E
10A 11 12 13 14
1' 2' 4'
E'
D'
F'
W16X40 (21)
W16X31 (25) W16X40 (21) W18X35 (26)
C12X30
W
2
7
X
8
4
(2
5
)
W
2
4
X
6
2
(3
8
)
W
2
7
X
8
4
(2
2
)
W
2
7
X
1
1
4
(6
0
)
W
2
7
X
8
4
(1
8
)
W21X50 (34) W18X35 (26)
W18X35 (27)
W18X35 (27) W24X76 (50)
C = .75
W24X76 (50)
C = 1.25"
W
1
8
X
3
5
W
1
8
X
5
0
W
2
7
X
8
4
W16X31 (12) W16X31 (26) W16X31 (21) W16X31 (25)
W16X31 (25)
W16X31 (25)
M
C
8
X
2
0
W
1
4
X
2
6
G'
5' 6' 7'
W24X76 (50)
C = 1
1.4'
B'
H
S
S
1
4
X
6
X
1
/2
W
2
7
X
8
4
(1
8
)
25' - 8"
13' - 6"
2
1
' - 4
"
6
' - 1
1
3
/4
"
1
' - 1
0
"
2' - 0 1/2"
W
2
7
X
8
4
(2
4
)
W
1
0
X
1
9
W
1
4
X
2
6
3'
9' - 0"
S
D
1
1
0
' - 8
"
1
6
' - 1
1
1
/2
"
21' - 10" 28' - 0" 7' - 1 7/8"
W24X76 (50)
C = 1
W24X76 (50)
C = 1.25
W16X31 (25)
(L
L
H
)
C12X30
W
2
7
X
8
4
W
6
X
1
6
(6
)
S3.3
4
S3.3
5
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
6
X
1
6
(6
)
W
2
1
X
4
4
C'
W12X22
W
6
X
1
6
(6
)
W21X50 (30)
W
1
6
X
3
1
(1
2
)
W
1
6
X
3
1
(1
2
)
W
1
8
X
3
5
(1
2
)
W24X62 (25)
W
8
X
1
5
W
8
X
1
5
W
8
X
1
5
6
' - 5
1
/4
"
7
' - 2
"
(TYP)
(TYP)
4' - 6"
4' - 6"
(130'-6")
(130'-6")
(1
3
0
'-6
")
1
S3.7
2
S3.7
3
S3.7
4
S3.7
5
S3.7
1
S4.2
2
S4.2
3
S4.2
S3.5
1
EXTERIOR CMU, TYP UNO.
BRICK VENEER NOT SHOWN
EXISTING EXISTING EXISTING EXISTING EXISTING
EXIST
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
COL
TO
COL
0' - 7"
T
Y
P
, U
N
O
SD1
SD1
67
.1
3

SD1
BRACED FRAME
LOCATION TYP
27' - 0"
0
' - 4
1
/2
"
0
' - 6
"
13' - 8"
13' - 8" 0
' - 6
"
C
6
C
6
C
6
C
6
W12X22
W12X22
W
1
2
X
2
2
W
1
2
X
2
2
W
1
2
X
2
2
W
1
2
X
2
2
L6X6X3/8
1
S3.4
SIM
2
S3.4
EXTERIOR FACE OF
EXISTING BRICK VENEER
EXTERIOR FACE
OF EXISTING
BRICK VENEER
W24X76 (50)
C = 1
W24X76 (50)
C = 1
T/SLAB EL: 130' - 8"
W8X24
T/LANDING SLAB
EL: 124' - 3"
TYP
(123'-10")
W8X24
W8X24
(123'-10")
W8X24
H
S
S
1
6
X
8
X
5
/8
W16X31
T/LANDING SLAB
EL: 124' - 3"
4
S3.4
4
S4.2
5
S3.4
5' - 1 3/8"
10' - 2 3/8"
7
' - 0
5
/8
"
4
' - 7
7
/8
"
6
5
/8
"
6
5
/8
"
1' - 8 3/8"
S
L
O
P
E
S
SLOPES
7
3
/8
"
7
1
/2
"
5
' - 0
"
8' - 0"
1
' - 2
1
/8
"
2' - 0"
2' - 11 3/4"
5' - 0"
3
' - 3
7
/8
"
4' - 3 1/2"
9' - 6 3/8"
D
O
W
N
DOWN W8X24
TENG & ASSOCIATES, INC.
Engineers/ Architects/ Planners
205 North Michigan Avenue
Chicago, Illinois 60601
Ph: 312- 616- 0000
c
CAUTION: DO NOT SCALE DRAWINGS. THIS
REPRODUCTION MAY BE AT A SIZE DIFFERENT
FROM ORIGINALLY DRAWN. THE OWNER & TENG
ASSUME NO RESPONSIBILITY FOR INCORRECT
SCALING. UNAUTHORIZED REPRODUCTION OR REUSE
IS STRICTLY PROHIBITED. NOT PUBLISHED- ALL
RIGHTS RESERVED. TENG EXPRESSLY DISCLAIMS
RESPONSIBILITY ARISING FROM UNAUTHORIZED USE
OF THESE DRAWINGS AND NOTES. AUTHORIZATION
MUST BE IN WRITING.
TENG & ASSOCIATES 2008
Scale:
NO. DATE
RECORD
DESCRIPTION
Drawn By:
Project No:
Sheet Number:
COLLEGE OF CIVIL &
ENVIRONMENTAL ENGINEERING
205 N. MATHEWS AVENUE
URBANA, ILLINOIS 61801
1 12- 15- 08 SD - OWNER REVIEW
NEWMARK STUDENT CENTER
ADDITION
2 02- 17- 09 DD - OWNER REVIEW
3 08- 18- 09 %50 CD - OWNER REVIEW
4 10- 16- 09 %95 CD - OWNER REVIEW
1
0
/
1
5
/
2
0
0
9

9
:3
0
:1
8

A
M
1/ 8" = 1' - 0"
S1.3
THIRD FLOOR
FRAMING PLAN
20959.001
PKM
1/8"= 1'-0"
1
THIRD FLOOR FRAMING PLAN
NORTH
STRUCTURAL STEEL LEGEND
C
x
W
1
2
X
2
2
(2
0
) C
=
1
(1
1
0
'-0
")
INDICATES BEAM FRAMING
OVER TUBE COLUMN
INDICATES BEAM FRAMING
OVER W COLUMN
INDICATES BEAM FRAMING
INTO SIDE OF COLUMN
COLUMN DESIGNATION
(COLUMN MARK)
REQ'D CAMBER AT MIDSPAN
OF BEAM (NONE IF OMITTED)
T/ BEAM ELEVATION
NUMBER OF 3/4" X 3 1/2" LONG
HEADED SHEAR STUDS
BEAM DESIGNATION
INDICATES LOCATION OF
BEAM SPLICE
INDICATES BEAM FRAMING
INTO SIDE OF BEAM
INDICATES BEAM FRAMING
OVER BEAM
INDICATES FULL MOMENT
CONNECTION OR ACTUAL MOMENT
(IF VALUE NOTED ON PLANS, THUS
M=x) OF BEAM INTO SIDE OF
COLUMN
BOTTOM FLANGE BRACE
LOCATION
DENOTES FACTORED AXIAL
REACT IN BEAM (KIPS)
SHEET NOTES:
1. T/SLAB, ELEVATION = 130'-6", UNO
2. T/STEEL, ELEVATION = 130'-0" UNO (X'-X")
3. INDICATES SPAN DIRECTION OF 3" GALVANIZED STEEL DECK (18 GAGE MIN) PLUS 3"
NORMAL WEIGHT CONCRETE TOPPING (6" TOTAL THICKNESS). REINFORCE WITH
STEEL FIBERS @30 PCY OR STRUX @4 PCY OR WWF 6x6-W2.1xW2.1.
4. STEEL FRAMING SHALL BE EVENLY SPACED IN BAYS, UNO.
5. SEE SHEET S0.01 & S0.02 FOR STRUCTURAL GENERAL NOTES AND ABBREVIATIONS.
6. SEE SHEET S3.1 FOR STEEL COLUMN SCHEDULE.
7. REFER TO SHEET S3.2 THRU S3.5 FOR STEEL FRAMING DETAILS.
8. COORDINATE ALL SLAB, BEAM, AND WALL OPENINGS WITH ARCH/MECH/ELEC/PLUMBINGDRAWINGS.
9. COORDINATE ALL DIMENSIONS WITH ARCH DRAWING