You are on page 1of 3

Column1 Aggregate Type Column3 Aggregate Type2

MATERIALS FROM STOCKPILE A B


% Of Agg. 30
SIEVE SIZE % PASSING %STOCK % PASSING
20 100 30 100
14 100 30 100
10 89 26.7 98
5 45 13.5 61
3.35 29 8.7 55
1.18 0 0 35
0.425 0 0 0
0.15 0 0 0
0.075 0 0 0
HIGHWAY ENGINEERING EAL334 : MARSHALL MIX DESIGN AGGREGATE GRADING
Instructions to users :
Please key in the required JKR Specification in Column K according to the mix type ACW10 or etc.
By trial and error, key in the appropriate mix percentage for each stockpile and compare the BLEND (Column J)
to Column K
Answer the Conclusion
Prepared by:
KKLIEW 2013
Column5 Aggregate Type3 Column7 Filler ( < OR =75 microns)
C FILLER
30 35
%STOCK % PASSING %STOCK % PASSING
30 100 35 100
30 100 35 100
29.4 100 35 100
18.3 97 33.95 100
16.5 94 32.9 100
10.5 65 22.75 100
0 45 15.75 100
0 25 8.75 100
0 8 2.8 95
Conclusion: Is mixing proportion in conformity with JKR specifications ?
A. Yes , if the % of passing in the BLEND ( Column J ) is within the acceptable range as stated in JKR Spec ( Column K)
B. No, if the above statement is not obeyed
Column9 Mixed aggregate percentage of passingCompare to
BLEND JKR SPEC LIMIT
5
%STOCK %
5 100 100
5 100 100
5 96.1 90-100
5 70.75 58-72
5 63.1 48-64
5 38.25 22-40
5 20.75 12-26
5 13.75 6-14
4.75 7.55 4-8
Is mixing proportion in conformity with JKR specifications ?
A. Yes , if the % of passing in the BLEND ( Column J ) is within the acceptable range as stated in JKR Spec ( Column K)
B. No, if the above statement is not obeyed

You might also like