Title: - Charring of Dry Filter of control fluid regeneration system
Abstract: - Control fluid regeneration system comprises of two recirculation pumps
(gear type), heater, dry filter, Fuller earths filter, and polishing filter. Control fluid from protection tank / control fluid tank is pumped by ecirculation pump and fed back to control fluid tank. !t is heated then it passes through dry filter where mechanical impurities are remo"ed. #ubse$uently it is passed through fuller earth and polishing filters for remo"ing ionic impurities. %ue to malfunctioning of heater, the control fluid is o"erheated and dry filters were charred by development of electrostatic charge in filter. Modification done at site& - %e"elopment of electrostatic charge can be restricted by pro"iding minimum flow through dry filter. 'his is done by pro"iding a "ent line from dry filter to control fluid tank with orifice (().*++). For this purpose spare "ent connection on the co"er of dry filter is pro"ided. Drawings / Schemes& -
Fig. 1.1 Dry filter housing Fig. 1. Dry filter element ,repared by itesh +oon (-r.'#.) / Fig. 1.! Control fluid regeneration scheme """"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""" " Fig. 1.# Modified control fluid regeneration scheme ,repared by itesh +oon (-r.'#.) ) CF Tank CF Tank Dry Filter Dry Filter Earth Filter Earth Filter Polishing Filter Polishing Filter Heater Heater Gear pumps Gear pumps CF Tank CF Tank Heater Heater Dry Filter Dry Filter Vent line with Vent line with orifice orifice ( 2 mm 2 mm Gear Pumps Gear Pumps Return line Return line