171205-00 KX6 + 3×0.

75
C1
elbaC Cable C2
ZAC sous le Beer - RD 836
F-27730 BUEIL C4
Tel : +33 (0)2 32 62 00 92
Fax : +33 (0)2 76 01 31 80
www.elbac.fr / info@elbac.fr 5 A3 A2 A1

Construction Electrical characteristics KX6 A


Group A B Impedance 75 ± 3 Ω
Inner conductor 1 Capacitance 67 ± 3 pF/m
Material Bare Copper Bare Copper Max DC resistance
Diameter 7 ×Ø 0.19mm 21 ×Ø 0.21mm Inner conductor 93.8 Ω/km
Section 0.22 mm² 0.75 mm² Outer conductor 22.6 Ω/km
Insulation 2 Propagation velocity ratio 84%
Material Solid PE PVC - Fire ret. Rated voltage 30 V
Color Natural Blue, Brown, Insulation resitance 20°C >500MΩ/km
Yellow with green line
Longitudinal attenuation
Diameter Ø3.7±0.10mm Ø2.0±0.15mm

Outer conductor 3
st Frequency Max attenuation
1 Layer MHz dB/100m
Material Copper Clad Alum. 10 3.7
200 17.0
Coverage 85%
400 25.0
Braiding 16×(7×Ø0.12mm)
800 35.5
Lay Length
Filler 4 Return loss
Material Chalk
Frequency Return loss
Assembly MHz dB
Type [ 30 – 1000 ] > 20
Flat cable double shotgun
Position Left Right
Quantity 1 coax 3 conductors Screening attenuation
Sheath KX 3C 5
Frequency Screen attenuation
Material PVC - Fire retardant MHz dB
[ 30 – 2000 ] >75
Color Black Black

Diameter Ø6.1±0.15 mm Ø5.7 ±0.15 mm

Mass 236 kg/km Electrical characteristics B


Marking on sheath Max DC resistance < 24 Ω/km
Printing « KX6 + 3×0.75 - elbaC 171205 – Rated voltage U0/U 450 / 750V
with XXX quantity in
meter still available WW/YY – XXX m » Insulation resitance 20°C > 200MΩ.km
per reel
WW/YY : Week/Year

Thermal characteristics
Color White / Pigment ink jet Rated Temperature 80°C
Step 1m
Notes
Meet Standards Barcode of 171205-R1
RoHS European directive

Packaging
-R1 : 100m / Easy reel drum
-W5 : 500m / Wooden drum

© copyright 2009 – elbaC Cable ® is a registered trademark 171205-00.pdf 14/03/2009 21:56:01