You are on page 1of 1

inlet duct

plenum
room
exhaust
room
exhaust line exhaust duct
R.C.C. COLUMN
EXTRACT / OUTLET
DUCT (300 x 300
MIN)
CROSSINGS MADE
IN DUCT TO RESIST
VIBRATION
FIXING MEMBERS
HOUSING
SCROLL
SIDE
SPIN
BAFFLE
CENTRE
PLATE
INLET
COLLAR
INLET
PLATE
SUPPORTS
SCROLL
OUTLET
OUTLET
DISCHARGE
BLAST
AREA
BACK
PLATE
BLADES
INLET
CONE
BEARING
SUPPORT
+103.5M
+104M
+99.5M
+100M
+100.5M
+101M
+101.5M
+102M
+102.5M
+103M
+103M
+102.5M
+98.5M
+97M
+100.5M
+101M
+101.5M
+102M
+102.5M
+97M
MAIN SUPPLY
REDUCER
BENDS
DUCTS
REDUCER
M.S ROD
M.S ANGLE
SUPPLY DIFFUSERS FROM
THE SIDES OF DUCTS
DIFFUSER
PROPELLER FAN
VIEW
FELT PAD
MOTOR
RENDER OR
PLASTER FINISH
MINERAL WOOL PACKING
TO SEPERATE BUILDERS
WORK INFILL
13 MINERAL WOOL
SLABS
75X65X16 MM FLANGE
GENERAL NOTES
DESCRIPTION
1. THERE ARE THREE KINDS OF MECHANICAL
VENTILATION SYSTEMS -
a. EXHUST VENTILATION ONLY, WITH A
SUPPLY OF
REPLACEMENT AIR BY NATURAL MEANS.
b. INPUTT OF AIR ONLY, THE EXHAUST AIR
FINDING ITS OWN WAY OUT OF THE
VENTILATED SPACE.
c. THE BALANCED SUPPLY AND EXTRACTION
OF AIR BY AN INTEGRATED SYSTEM, WHICH
IS CALLED AS THE 'PLENUM SYSTEM'.
2. MECHANICAL VENTILATION WILL NOT
PROVIDE THE FULL ENVIRONMENT CONTROL
OF THE AIR CONDITIONED SYSTEM,
HOWEVER IT IS CAPABLE OF MEETING THE
BASIC VENTILATION NEEDS.
THERE ARE FOUR KINDS OF VENTILATION
SYSTEMS,
NAMELY-
1. NATURAL INLET & NATURAL OUTLET
2.MECAHNICAL INLET & MECHANICAL
OUTLET
3.NATURAL INLET & MECHANICAL OUTLET
4.MECHANICAL INLET & NATURAL OUTLET
THE REDUCTION OF DUCTS IN CASE A FLAT
SLAB IS USED FOR THE BASEMENT CAN BE
DONE DEPTH WISE
INCASE OF A NORMAL COLUMN BEAM
STRUCTURE THE REDUCTION IS USUALLY
DONE WIDTH WISE.
SECTION AA SCALE 1:200
SCHEMATIC DETAIL OF BASEMENT VENTILATION
SCALE 1:50
CENTRIFUGAL FAN
DETAIL SCALE 1:20
NO. SPECIFICATION SYMBOL
1. PLENUM ROOM
2. EXHAUST ROOM
3. INLET DUCT
4. EXHAUST DUCT
LEGEND
DETAIL C
Padmashree Dr. D.Y.Patil College of Architecture
Nerul, Navi Mumbai
4th YEAR, B.ARCH
Batch : 2009 - 2014
Roll no. :
Date :
Name :
Subject :
Topic : Assign. No.:
BUILDINGSERVICES
MECHANICAL VENTILATION
SAURABH P.
5
APR 1, 2013
VIEW - BRANCH DUCTS AND AIR VENTS SCALE 1:50
DUCT INSULATION DETAIL
BASEMENT PLAN
SCALE 1 :200
KEY PLAN OF BASEMENT
SCALE 1 :500
TOTAL VOLUME OF BASEMENT =27X 69X 4
=7452M3
ASSUMING THE TOTAL VOLUME IS TO BE
VENTILATED IN 1HOUR.
7452CMH
OPENINGS
WINDOW AREA =0.7X 0.6X 44
=18.48SQM
WIND VELOCITY =4.2MILES/HR =6.75KM/HR
=6750M/HR
TOTAL VENTILATED VOLUME BY NATURAL
WIND =6750X 18.48
=124740CMH
HENCE THE BASEMENT IS WELL VENTILATED
WHEN WINDS ARE BLOWING. WHILE IN
SEASONS WHEN WINDS BLOW WITH LOWER
PACE THERE IS NEED TO PROVIDE
MECHANICAL VENTILATION.
CALCULATIONS
DIRECTION OF WINDS
A
A